1. button The unit will automatically begin operating If the ambient temperature is higher than 74 F the unit will work in cooling mode If the temperature is at or below 74 the unit will work in ventilation fan mode At this time the indicator lights will show any functions that are in progress Please note that the display window will only show ambient room temperatures ranging from 32 F to 122 F To turn the unit off press ON OFF button again Setting the Mode Function 1 Press the MODE button to select the desired mode cooling fan or heating Heating mode is only available on the AC 14000H 2 selected mode s indicator light will turn on Setting the Temperature 1 2 Press the Up or Down button to change the set temperature The display window will indicate the set temperature If no temperature is set the display will show the ambient room temperature Please note that the default temperature for cooling is 75 F and 68 F for heating Setting the Fan Ventilation Speed 1 Press the SPEED button to select the desired fan speed high medium or low The desired fan speed will show on the display screen If the unit is in AUTO mode it will automatically choose the fan speed depending on the room s ambient temperature Setting the Timer 1 Press the TIMER button to set the desired number operating hours from 1 to 24 hours The display will show the number of hou
2. designed to fit the H specifications of this unit Do not extend it with your own hose as this can cause the air conditioner to malfunction FIG 11 K0080 1 2 Installing the Activated Carbon Filters 1 Remove the filter frames from the unit left and right sides 2 Separate the filters from the filter frames 3 Remove the activated carbon filters from their plastic bags 4 Attach the activated carbon filters onto the filter frames 5 Re fix the filters to the filter frames make sure the active carbon filters will be hold properly 6 Re install the filter frames to the unit f Ze ZZ Ha hp H ge 2 ee FA ZZ a FIG 12 K0080 1 2 OPERATING INSTRUCTIONS Control Panel ON OFF power button Full water tank indicator Fan mode indicator Mode selection button Heater indicator AC 14000H only Fahrenheit indicator Swing button Sleep mode indicator Sleep mode button 0 Temperature decrease button 1 Temperature display a ee NO AG 12 13 14 15 16 17 18 19 20 21 FIG 13 Remote control receiver Timer display Temperature increase button Timer button lonizer indicator lonizer button Fan speed indicator Automatic mode indicator Fan speed button Cooling mode indicator K0080 1 2 Turning the Unit On and Off 1 Press the ON OFF
3. in place 7 Turn the unit back on The full tank indicator light should now turn off K0080 1 2 For Continuous Drainage e Remove the drain knob and rubber Pat os plug from the drain hole and retain it for future use e Connect the included drain tube to the drain hole e Connect the other end of the tube to a Rubber plug gt Drain knob oS drain see Fig 18 FIG 17 e The drain tube may be extended by adding an extension tube with a suitable connector FIG 18 Drain tube Please Note 1 The drain must be at or below the at level of the drainage port an 2 The full water tank indicator will not work when the unit is being continuously drained Original drain tube FIG 19 3 To extend the drain tube you can Loo connect it with another hose with an Extended drain tube OD 18MM overall diameter of approximately 0 7 18 mm 11 K0080 1 2 For Heating Mode AC 14000E Only While using the heating function please note the following 1 In order to properly exhaust cool air make sure the exhaust hose and window kit are properly installed refer to page 4 for instructions 2 Setup the air conditioner for continuous drainage using the included drain tube refer to page 12 for instructions FIG 20 3 The working range for the heating function is 45 F to 77 F The unit may not provide optimal heating if used in temperatures outsi
4. room temperature lower than the set temperature Is the filter dusty or dirty Is the air inlet or outlet blocked Is the unit placed in direct sunlight If so close any curtains or move the unit to a more shaded area Are too many windows or doors open Are there too many people in the room Are there additional heat sources in the room Is the filter dusty or dirty Is the air inlet or outlet blocked Is the ambient room temperature lower than the set temperature Is the machine positioned unevenly Make sure the air conditioner is placed on a level solid surface Is the compressor s overheat protection function activated If so wait for the temperature to drop and then turn on the unit again yx Never try to repair or dismantle the unit yourself Unauthorized repairs can void your warranty and endanger the user K0080 1 2 TECHNICAL SPECIFICATIONS Model Number AC 14000E AC 14000H Power Ampere Consumption 1420W 12 8A for Cooling Power Ampere Consumption N A 1420W 12 8A for Heating Air Volume max speed 450m h Voltage Frequency 115V 60Hz Compressor Type Rotary Refrigerant Type R 410A Number of Fan Speeds 3 Timer 1 24 hours Exhaust Pipe Dimensions 5 6 X 59 1 Net Weight 72 8 Ibs Product Dimensions 17 7 x14 4 x 32 5 Notes 1 Heating function is only for model number AC 14000H 2 The data marked with may vary for technica
5. sunniest parts of the day while the air conditioner is in operation e Frequently clean the portable air conditioner s filters e Once the room or area has reached your desired comfort level be sure to reduce the unit s temperature and ventilation settings K0080 1 2 PARTS LIST Front Back 1 Control panel 5 Air filters 2 Louvers 6 Air inlets 3 Carrying handle 7 Exhaust air outlet 4 Casters 8 Cord wrap 9 Rubber plug drainage hole Accessories 10 Hose adapter goes over the exhaust hose and into the back of the unit 11 Exhaust hose 12 Round connector to be used in between the hose and window kit or through a wall 13 Exhaust cap 14 Extendable window kit 15 Drain hose for continuous drainage 16 Activated carbon filter 17 Remote control K0080 1 2 INSTALLATION INSTRUCTIONS Installing the Exhaust Hose and Window Kit The unit is a portable air conditioner that may be moved from room to room Hot air must be exhausted out of the room for the appliance to work This can be done with the included window kit or by cutting a hole into a wall 1 Venting Through a Window Using the Window Kit FIG S e Attach the round connector to the exhaust hose and secure it in place with screws Then insert the other end of the exhaust hose
6. K0080 1 2 6 PLEASE READ AND SAVE THESE INSTRUCTIONS NewAir AC 14000E AC 14000H Portable Air Conditioner Owner s Manual K0080 1 2 BEFORE USE GENERAL SAFETY INSTRUCTIONS e ALWAYS OPERATE THE UNIT IN AN UPRIGHT POSITION AND PLACE IT ON A FLAT LEVEL SURFACE AT LEAST 14 36 CM FROM ANY OBJECTS OR COMBUSTIBLE SURFACES FIG 1 amp 4 e DONOT PLACE OBJECTS ON THE UNIT AND DO NOT COVER OR OBSTRUCT THE INLET OR OUTLET GRILLS FIG 2 e CLOSELY SUPERVISE ANY CHILDREN AND PETS WHEN THE UNIT IS IN USE e THIS APPLIANCE IS NOT INTENDED FOR USE BY PERSONS INCLUDING CHILDREN WITH REDUCED PHYSICAL SENSORY OR MENTAL CAPABILITIES OR LACK OF EXPERIENCE AND KNOWLEDGE UNLESS THEY HAVE BEEN GIVEN SUPERVISED TO ENSURE THAT THEY DO NOT PLAY WITH THE APPLIANCE FG 2 ELECTRICAL SAFETY 7 THIS APPLIANCE IS FOR INDOOR USE ONLY e ALWAYS TURN OFF THE UNIT AND UNPLUG IT WHEN NOT IN USE e DO NOT USE THIS UNIT IN EXCESSIVELY HUMID OR WET ENVRIONMENTS FIG 3 e DO NOT PULL OR PLACE STRAIN ON THE POWER CORD WHEN MOVING THE APPLIANCE e IF THE POWER CORD IS DAMAGED IT MUST BE REPLACED BY AN ELECTRICIAN OR SPECIALIZED TECHNICIAN AUTHORIZED BY THE MANUFACTURER IN ORDER TO PREVENT FIRE FOR MAXIMUM EFFICENCY e Make sure doors and windows are closed while the portable air conditioner is in use Also keep curtains and blinds closed during the
7. de this range K0080 1 2 MAINTENANCE INSTRUCTIONS Always unplug the air conditioner from the power supply before cleaning To maximize the efficiency of the air conditioner regularly clean the unit Cleaning the Housing e Usea soft damp cloth to wipe the body clean e Never use harsh chemicals gasoline detergents chemically treated cloths or other cleansing solutions These all could possibly hurt the cabinet Cleaning the Filters e Use a vacuum cleaner or tap the filter lightly to remove loose dust and dirt from the filters Rinse the filters under running water no warmer than 104 F e Thoroughly dry the filters before replacing it back into the unit e Do not use the air conditioner without the filters End of Season Storage e Completely drain out any condensed water from the unit e Set the air conditioner on fan mode ventilation only for a few hours to dry the inside of the unit e Clean or change the filter e Unplug and wrap the power cord around the cord wrap as sown Fig 21 e Place the unit back in its original carton and store it in a clean dry area FIG 21 K0080 1 2 TROUBLESHOOTING The air conditioner does not operate The unit does not produce adequate cooling The unit is noisy The compressor does not work Is the air conditioner plugged in Is the power outlet functioning correctly Is the full water tank indicator light flashing Is the ambient
8. dehumidification mode the temperature cannot be adjusted and the fan speed will be automatically set to low Heating Mode When the air conditioner is in heating mode ambient warm air is recycled and used to heat your immediate area The exhaust pipe will still need to be fitted onto the unit in order for the cold air to be removed When in heating mode the machine can be set on HIGH or LOW speed K0080 1 2 lonizer Press IONIZIER button to activate the ionizer function This will remove harmful particles from the air Error Messages If there is an error with the air conditioner the LCD screen will display E1 or E2 If either of these error messages appears please contact the manufacturer or a service center All of the above functions can be controlled with A Va a 9 the included remote M l mi The remote requires 2 AAA batteries Ve ODL FIG 15 S S Please Note 1 prolong the life of the compressor after turning off the unit please wait at least 3 minutes before turning it back on 2 cooling system will turn off if the ambient temperature is lower than the set temperature However the fan will continue operating at the set level Once the ambient temperature rises above the set temperature cooling will resume 3 heating system will turn off if the ambient temperature is higher than the set temperature The ventilation fan will continue operating at the
9. into the window kit s round opening e Open your window and insert the window kit into the open gap Adjust the size of the kit if necessary by sliding the window across so that the window kit is securely held into place This technique may also be used for sash windows 2 Venting Through a Wall 7 Wall or Window Round connector ce C FIG 7 FIG 6 e Cuta5 95 151 mm diameter hole in the wall e Insert the exhaust hose through the hole On the other side of the wall attach the round connector to the exhaust hose with screws Fig 7 When the air conditioner is not in use cover the hole with the provided exhaust cap 3 K0080 1 2 Positioning the Exhaust Hose e Slide the hose adaptor over the opening on the back of 1 the unit e Then insert one end of the FIG 8 exhaust hose into the adapter e Avoid kinks and bends in the exhaust hose This can cause moist air to 1 accumulate resulting in overheating and unexpected shut offs e The exhaust hose may be extended from 12 300 mm to 59 1500 mm but for FIG 9 maximum efficiency use the shortest hose length possible _ FIG 10 WARNING The included exhaust hose is specifically
10. l reasons for more accurate data please refer to the rating label found on the back of the unit 3 Measuring condition for the above specifications Cooling DB 95 F WB 82 94 F Heating DB 68 F WB 59 F D B dry bulb temperature room temperature W B wet bulb temperature relative humidity S Reset Button If you plug in the Air Conditioner and there is no green light on the plug cS Test Button press the reset button on the LCDI plug The green light should be lit TEST y indicating that the air conditioner is getting power from the electrical outlet Green Light If the plug continues to trip which is a USA national safety standard feature and the green light goes off the cord may be damaged preventing you from resetting the unit For your safety contact a licensed electrician
11. rs being set as you press the TIMER button If the TIMER is not set the unit will work continuously By pressing the timer but without selecting any other modes or settings you can set the number of hours to be delayed before the unit turns on For example if you set the timer to 2 the unit will automatically turn on after 2 hours K0080 1 2 Sleep Mode 1 When in cooling mode press the SLEEP button The set temperature will increase 2 F on the first hour another 2 F on the second hour and then maintain that temperature 2 When in heating mode press the SLEEP button The set temperature will decrease 2 F on the 1st hour another 2 F on the second hour and then maintain that temperature 3 In sleep mode the fan will be automatically set to low By pressing the SLEEP button again the set temperature and fan speed will revert back to previous settings 4 The unit will shut down automatically after it has been in sleep mode for 12 hours 5 Sleep mode will not work when the unit is in fan dehumidification or auto mode It will only work in cooling or heating mode Swing Function 1 To activate the unit s swinging louvers press the SWING button The louvers will rise in 3 different angles 45 60 and 75 2 Once the air conditioner is turned on the louvers will rise to a 75 first and then automatically return to 45 Dehumidification Function When the air conditioner is in
12. set level Once the ambient temperature drops below the set temperature heating will resume 4 This machine is equipped with an anti frost function When using the heating function in low temperatures the heater will occasionally stop heating in order to melt any frost that has accumulated within the air conditioner Normal operation will resume in a few moments K0080 1 2 DRAINING THE UNIT During the cooling process some water will be extracted from the air and stored within the unit s water reservoir If the water reservoir is full both the compressor and motor will stop and the unit will beep press any button to stop the beeping sound The full water tank indicator light will also start flashing To resume cooling empty the reservoir by following these steps 1 Turn off the air conditioner and unplug it from the wall socket To prevent water leakage avoid moving the unit when full 2 Place a container such as a small pan underneath the drainage hole 3 Remove the drain knob and rubber plug from the drainage hole and allow the water to drain out 4 When the container is almost full place the rubber plug back into the drainage hole empty the container and place the drain knob back over the rubber Water hole _ Rubber plug plug Rubber plug Drain knob 5 Repeat these steps until the water reservoir is completely empty 6 Replace the rubber plug and make FIG 16 sure it is firmly
Download Pdf Manuals
Related Search
Related Contents
Labour Force Survey User Guide Adobe Creative Suite CS4 Design Premium, Win, DVD, ES, UPG 取扱説明書 Eglo 20956A Installation Guide Reuse of softwa orientated to Reuse of software components en collaboration avec les communes - de la gestion des déchets à l TABLE OF CONTENTS - thegroesbecks.us Home Page ART2543 User`s Manual Samsung <span style="unicode-bidi: embed;">SU10F70SD שואב עומד יוקרתי, 130 וואט יניקה</span> מדריך למשתמש (Windows 7) 議事録 - 横浜市 Copyright © All rights reserved.