Neuro Logic Systems 1U User's Manual

image

Contents

1. ENL NEURO LOGIC S AS INC wildy solaris READE Table of Contents Whats in Wie BOX acancacecoatccenaseasenesiecsacracsecaneenaceas hen saeedeeacnenessianenopapmeawesia Hardware Installation 28e2etssaqcnceecente tec eeneeaneesse eee eamececsacasas an eneeteceeepeae eters Cable Management Installation 0 cccce eee e eee eee e eee eee eaeeeaae eats eaeeeae eaten Connecting your LCD Keyboard cccce cece eee ee cence tees tees seats eae aadar Operating your LOD KeybOard ccc cece cece cece eect eee eee e eee eeeeeeeeeeaeeenaeeae eas Navigating the WIC ss dasacns ta vtemcsccatsascn na ETRE SEANAR oesaecevinnlaxsanaeecue On Screen Display OSD M NnusS cccce cece eee ee ee tenet seats eeeeaeeeaaeeaeeeaeees Trouble Shooting Image QuAIity 0 ccc cece cece cece eects eae eae eee eae easeaaeeeeneney DCC IMC CON S eesinsh aE Ea EN Ra EEA E LAS AREN ESTATE I PEE A A E E E E O ET TTET 07 01 06 Rev 1 0 CON W PO 11 12 13 1U 17 amp 19 LCD and Sun Keyboard Installation guide for the RFT2 17 19 In to a 4 post 19 inch EIA cabinet Page 1 of 13 RFT2 Rack Kit Installation Guide Box Inventory As you unpack the kit ensure that you have the following items included in the box 1 1U LCD with Keyboard 1 3m HD 15 to HD 15 Video Cable 1 3m DVI D to DVI D Video Cable 1 3m A to B USB Cable 1 2m IEC Power Cable 1 Cable Management S
2. Carefully assemble the two slide members together Push the tray assembly in until the slides latch together Release the lock mechanisms as shown in step 3 in order to slide the tray assembly completely closed You are now ready to install the Cable Management System See next page 07 01 06 Rev 1 0 Page 5of 13 RFT2 Rack Kit Installation Guide Cable Management Installation 1 With the RFT installed go to the back of the rack to install the cabl t system iti install the cable management system Note the guide that will fit into 2 Attach Part A to part extension of outer member on the mating portion on the slide the left slide 3 Connect Part B to the inside right hand side slide member by sliding it into place A click will be heard once it is secured The Cable Management System is designed to have the cross support beam on the bottom not the top 4 Connect Part C to the outside right hand side slide member Note that the extruded portion on the top of Part C needs to line up with the mating portion on the outer slide member Similar to Step 2 above A click will be heard once it is secured 5 Insert Part D into Part A on the left hand side The large tab on Part A will keep Part D in place 07 01 06 Rev 1 0 Page 6 of 13 RFT2 Rack Kit Installation Guide Connecting your LCD Keyboard Step Note Before connecting the LCD monitor keyboard to a KVM or Server all systems should be turned
3. Resolution 1280x1024 Protective Covering 2mm strengthened glass Keyboard Specifications Type USB 1 1 Pointing Device Three button integrated trackball Form Factor Size without Racksides Length with Slides and Cable Ma Weight unpackaged Storage Operating Temperature Range 25 C to 60 C 0 C to 50 C Operating Humidity 5 to 95 RH non condensing Approvals EMC EN55022 Class A FCCA RoHS Solaris Ready Certified Safety CSA 22 2 950 NRTL C IEC 950 EN60950 CE Approval Power Supply Internal auto ranging 90 264VAC 50 60Hz Power Consumption 25W lt 5W in standby Warranty 24 months 07 01 06 Rev 1 0 Page 12 of 13 RFT2 Rack Kit Installation Guide Warranty Neuro Logic Systems warrants to the original retail purchaser that this product is and will be free from defects in materials and workmanship for a period of 24 months from the date of purchase During the warranty period purchaser must promptly call Neuro Logic Systems 1 805 389 5435 to log any such defects in materials and workmanship If you purchased the unit from a distributor or reseller contact them first as they may be able to assist you The warranty is void under the following conditions 1 If non Neuro Logic Systems approved cabling is attached to the product Poorly constructed and or miswired cabling can diminish video quality and damage equipment Neuro Logic available cabling is built to high quality standards utilizing overall braided shiel
4. cables connected power on the LCD monitor by lifting the head unit There is a power button at the rear of the LCD which is actuated by lifting the head of the LCD monitor The LED situated on the top of the LCD panel will alert you to its status It will illuminate green when everything is working properly If the LED is orange the monitor is powered up but not receiving a valid video signal Once the LCD monitor is powered on power on the connected server and or KVM and log in or otherwise ensure that a full screen image is displayed NOTE If the monitor does not power up automatically when raised the power button at the rear of the unit may need to be cycled There is also a Power button on the top of the LCD which may also need to be cycled NOTE It is important to ensure that a full screen image is being displayed at the time the monitor is in the Auto Adjust function The display may be mis positioned if an image with a black border Such as a login screen or partial screen is used 07 01 06 Rev 1 0 Page 8 of 13 RFT2 Rack Kit Installation Guide Navigating the Menu The OSD Controls may be located on the back or the top of the LCD head Although not required you can make numerous adjustments to your monitor using the on screen menu To access the OSD On Screen Display menu Press the MENU button located at the top of the LCD monitor The table below describes various function controls of the LCD Monitor The control
5. off 1 The keyboard and trackball s design allows it to be used with most Sun systems The RFT2 comes with a USB style connector 2 The monitor uses a standard HD 15 or DVI male video connector If your Sun system uses a DB13W3 connection you can use a Sun adapter to interface between the LCD connector and the Sun system PN X3872A 3 If both HD 15 and DVI cables are connected at the same time HD 15 will be the default input 4 Connect the monitor to a power source The LCD Monitor s power supply is auto ranging and will operate on AC voltages ranging from 90 264V and 50 60 Hz The monitor uses an IEC 320 C14 connector and a 2m IEC C13 to C14 cable is included An adapter will be required to interface with other connector types 5 Secure the cables to ensure they will not bind when operating the LCD keyboard slide mechanism Cycle the tray in and out of the cabinet to ensure there is enough of a service loop in the cables Zip ties may be used to hold the cables securely to the back of the unit 07 01 06 Rev 1 0 Detail fevsovosd Page 7of 13 RFT2 Rack Kit Installation Guide Operating the LCD Keyboard NOTE It is important to ensure that the monitor is connected and powered on prior to powering up the connected server and or KVM Powering up the KVM then the server last will with some servers allow the video card and monitor to self configure to the correct settings After the unit has been installed and all
6. buttons can be accessed from the top of the LCD monitor once it has been raised in to the operating position The OSD menu will disappear after a pre set time of no use Function when not Function when displaying Label Control displaying menu menu gt O Brightness minus Brightness plus Displays the On Screen Display OSD Decrease display brightness Increase display brightness mout Selec Switches video input p signal from DVI to from VGA l Turn power on and off 07 01 06 Rev 1 0 Selects item high lighted in blue Decreases or changes value of the adjustment item or moves down in a menu Increases or changes value of the adjustment item or moves up in a menu No Function Turn power on and off manually Page 9 of 13 RFT2 Rack Kit Installation Guide On Screen Display OSD Menus The menu pages can be displayed by pressing the Menu button Not all menu functions can be adjusted Menu items or layout may change without notice Picture VGA Adjust Temperature Setup Source Information Exit Controls for Picture Quality most of these settings are optimized by using the Auto Adjust feature in the VGA Adjust menu option Brightness Contrast Dimming Sharpness Adjusts the way the picture is displayed H Position moves the image horizontally V Position moves the image up or down H Size increases the width of the image Phase Adjusts horizontal scan rate Set
7. by Auto Adjust Auto Adjust Auto Color Controls for picture coolness or warmth User 4200k 5000k 6500k 7500k 9300k Reset Resets all settings back to factory defaults Normally auto sensing based on what cable is connected Manual switching can be used if 2 cables are connected at once VGA DVI Displays various information about the LCD such as bios version and current resolution settings Quits OSD This may also be obtained by letting the OSD time out the period of inactivity where no buttons are pressed Auto Adjustment will reset all parameters to the optimum values which the LCD determines This is the optimum method of setting up the LCD 07 01 06 Rev 1 0 Page 10 of 13 RFT2 Rack Kit Installation Guide Trouble Shooting Bad Image Quality Image quality problems blurry characters distorted images etc are usually caused by one of the following The graphics card is running at the wrong resolution for the LCD monitor The monitor optimally runs at a resolution of 1280x1024x60Hz To display the monitor resolution press the Menu Button at the top of the LCD twice The on screen display will display the current resolution and frequency If this is not what was expected variances of a fraction of a hertz in the displayed refresh rate are not significant adjust the settings of your graphics card to display 1280x1024 at 60Hz resolution The monitor has not been adjusted for the particula
8. d to comply with FCC emission standards and each cable is individually tested under load If abuse mishandling unauthorized repair or use other than intended has caused the product to be defective or malfunction lf unauthorized modifications were made to product lf unreported damages occurred in any shipment of the product lf damages were due to caused by equipment or software not provided by Neuro Logic Systems If the product is used with non grounded or incorrectly polarized AC power Aa SOLS EXCEPT AS SPECIFICALLY PROVIDED ABOVE NEURO LOGIC SYSTEMS MAKES NO WARRANTIES EITHER EXPRESS OR IMPLIED AS TO ANY MATTER WHATSOEVER INCLUDING WITHOUT LIMITATION THE CONDITION OF THE PRODUCT ITS MERCHANTABILITY OR ITS FITNESS FOR ANY PARTICULAR PURPOSE EXCEPT AS EXPRESSLY PROVIDED ABOVE NEURO LOGIC SYSTEMS SHALL NOT BE LIABLE FOR LOSS OF PROFIT LOSS OF BUSINESS SPECIAL OR CONSEQUENTIAL DAMAGES OR OTHER FINANCIAL LOSS WHICH MAY BE CAUSED BY DIRECTLY OR INDIRECTLY THE INADEQUACY OF THE PRODUCT FOR ANY PURPOSE OR USE THEREOF OR BY ANY DEFECT OR DEFICIENCY THEREIN EVEN IF NEURO LOGIC SYSTEMS OR AN AUTHORIZED NEURO LOGIC SYSTEMS DEALER HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES OR LOSSES Nothing in these terms will reduce your statutory rights 07 01 06 Rev 1 0 Page 13 of 13
9. nd both slides to the open position Once extended unlock the outer slide members by pressing or pulling on the blue tab on the side of the slides The outer slide member can now be removed from the tray assembly The inner slides are left attached to the tray assembly Also remove the Cable Management System if installed This makes the installation easier 4 Adjust the rear slide mounting brackets to the proper depth The rear slide mounting brackets are pre assembled but may need to be adjusted to the l proper distance measured in step 2 The rear AA A bracket that will mount to the rack rails is free sliding SO no screws are required 5 Insert nut clips into the rack mounting rails as required If your rack has square or round untapped holes you will need to use 10 32 nut clips Do not place a nut in the center hole this is just for o illustration purposes r 07 01 06 Rev 1 0 Page 4 of 13 RFT2 Rack Kit Installation Guide Step Detail 6 Attach the left slide rail assembly to the rack mounting rail by using 4 10 32 x 1 2 screws for the front and rear slide mounting brackets 7 Repeat for the right slide rail assembly 8 Extend the slides from the rack 9 Install the LCD keyboard assembly into the rack Lift the tray assembly and approach the rack with the rear of the tray facing the rack enclosure Align the tray assembly with the slide rails in the rack
10. r graphics card driving it Perform an Auto Adjustment after logging in ensuring a full screen image is being displayed prior to running the Auto Adjustment In some cases it may be necessary to power cycle the monitor prior to running the Auto Adjust function e g when the resolution is altered during the system boot sequence Improperly matched timing Some computer systems communicate with the monitor during system startup and configure an optimum resolution Ensure that the monitor is powered on before the computer system to ensure that this process can occur Refresh set rate is too high 07 01 06 Rev 1 0 For LCD monitors it is recommended the refresh rate be set to 60 Hz The monitor is capable of running at higher refresh rates but optimally runs at 60Hz The LCD Monitor uses advanced technology that has no flicker in normal operation and it is never influenced by the refresh rate When the monitor is run at refresh rates higher than 60Hz there is processing overhead which can cause a number of performance issues included degraded image quality and greater tendency for interference The first and foremost recommended vertical refresh rate for the LCD Monitor is 60Hz 1280x1024 60Hz Use other rates only if the connected system s graphics card cannot accommodate 1280x1024x60Hz Page 11 of 13 RFT2 Rack Kit Installation Guide Specifications Keyboard USB Ports Rack er LCD Panel Specifications LCD Native Pixel
11. ystem unless ordered without 2 Outer Rails Mounting to Rack 2 Inner Rails Already mounted to RFT 1 Mounting Hardware 4 Zip Ties for securing cables to the back of the unit 07 01 06 Rev 1 0 Page 2 of 13 RFT2 Rack Kit Installation Guide Hardware Installation Step 1 The following instructions assume that your equipment rack utilizes caged nuts If you rack has pre tapped holes there will be no need to include the caged nuts and the size of the mounting bolts may vary from that described Determine the vertical location for the LCD keyboard in the rack Mark the location with tape or a pencil This product requires one rack unit 1 of vertical space Mount the LCD keyboard at a convenient height for an average user Approx 44 from floor 2 Measure the distance from the front rack mounting rail to the rear rack mounting rail This distance will be needed during installation of the Rear slide mounting brackets in step 4 Distance 07 01 06 Rev 1 0 Detail Ensure the bottom of the kit is properly positioned ina rack unit Page 3 of 13 RFT2 Rack Kit Installation Guide Step Detail 3 Remove the slides from the tray assembly The m slides come shipped attached to the tray assembly sO 0O the outer slide members must be removed to be T properly installed into the rack To remove the outer slide members fully exte