NEC X463UN-TMX4P Installation and Setup Guide

image

Contents

1. The ideal cabling set up is shown below to match the ideal monitor ID configuration However DVI daisy chaining can be done different ways and still yield the same results Note that the connections for each X463UN monitor are on the bottom of each display not the side as shown in the image below It may be helpful to start wiring before mounting DVI D OUT DVI D OUT mt Display 2 _ E m ji DVI D IN DVI D IN DVI D OUT Ta DVI D IN j Display 4 wi Tui DVI D IN To digital output DVI D Connect the null modem cabling to each display It is recommended to connect from Display 1 to Display 2 from Display 2 to Display 3 and from Display 3 to Display 4 Note that the null modem cable needed to run from the source computer to Display 1 is not included in this bundle This will need to be purchased separately to control the display remotely over RS232 Also loop through the provided IR Remote control cables NJ EC NEC Display Solutions of America Inc QIG TMXP 46UN X463UN TMX4P Rev 1 1 IR In RS232 Out IR Out RS232 In 4 Apply the OverFrame bezel kit to the video wall Please follow instructions provided with kit KT 46UN OF2 Overframe Kit 5 screw the IR Receiver KT RC directly to the outside of the video wall and plug it directly into the IR In terminal of Display 1 6 set each monitor ID up individually through the MULTI DSP menu within the OSD It s recommended that the ID s
2. go from left to right with the ID No 1 being in the top left corner MULTI DISPLAY MONITOR ID IR CONTROL TILE MATRIX POWER ON DELAY POWER INDICATOR EXTERNAL CONTROL SETTING COPY MULTI DISPLAY RESET 00 Select 660 Change G id Return HENUA H MET NJ EC NEC Display Solutions of America Inc QIG TMXP 46UN X463UN TMX4P Rev 1 1 Note that after the ID s are set there are two different ways to communicate to each screen via the IR Remote If the setting for the IR Control within the MULTI DSP menu is set to Normal then the IR remote control cabling is being utilized for communication In order to communicate to each screen individually hold down the Remote ID Set button on the remote control tap the number of the ID that you want to communicate with then release the Remote ID Set button To test if this was done correctly press the MENU button and the OSD should now only appear on the display in which the remote control is corresponding to Also more information on this is located within the User s Manual MULTI DISPLAY MONITOR ID NORMAL IR CONTROL PRIMARY TILE MATRIX SECONDARY POWER ON DELAY LOGK POWER INDICATOR EXTERNAL CONTROL SETTING COPY MULTI DISPLAY RESET O0 Select O a Goto Adjustment D Return MENU AH ET To communicate to each display over the RS232 connection make sure that the first display monitor ID 1 has its IR control set to Primary while all ot
3. NJ EC NEC Display Solutions of America Inc QIG TMXP 46UN X463UN TMX4P Rev 1 1 yf Le Yi tj Yi Hy R Yj Yy Vf i Y Yj Parts List O O O O O O O DD NOTES O X463UN Displays Onsite Service Warranties ONSITE 46 16 Peerless Pullout Wall Mounts DS VW765 LAND Custom Peerless Spacers DS VWS013 10ft DVI D to DVI D M M cables 15ft DVI D to DVI D M M cable 10ft Null Modem to Null Modem F F cables IR Remote Control Kit KT RC Overframe Bezel Kits KT 46UN OF 2 Tripp Lite 6 Outlet Strip ISOBar6 NNSGSENSSS Any walls that this video wall solution is anchored to must be strong enough to support the displays and the installation must be in accordance with any local building codes All mounting apparatuses must make secure contact to wooden studs o Please read entire document before starting installation NJ EC NEC Display Solutions of America Inc QIG TMXP 46UN 1 2 X463UN TMX4P Rev 1 1 For mounting information please refer to the Installation Instructions provided by Peerless Manufacturing inside of the box of the DS VW765 LAND mount units Connect the NEC displays using the included DVI cables and the integrated DVI loopthrough connections on the bottom of each monitor Note that the DVI connection closest to the front of the display is the in connection while the connection closest to the wall is the out connection
4. hers are set to Secondary When this is set press the Display button and the Monitor ID and Target ID should come up in the left corner of each screen If this is not working correctly check your cable connections monitor ID s and Primary Secondary IR control classifications Use the and buttons on the remote to change the Target ID to the desired display you wish to communicate with then press Display again If the menu is then pressed the OSD menu should appear on the screen of the desired ID MULTI DISPLAY MONITOR ID IR CONTROL PRIMARY MONIFORID 1 TARGET IDAE TILE MATRIX SECONDARY POWER ON DELAY LOCK POWER INDICATOR EXTERNAL CONTROL SETTING COPY MULTI DISPLAY RESET 00 Choose ap Mark d Return EN AH GES 7 Use the TileMatrix feature to setup the 2x2 Video Wall The Tilematrix feature of the NEC Display allows for one image to be expanded and displayed over a 2x2 Video Wall Setup This is accessed through the OSD On Screen Display Controls under the MULTI DSP NJ EC NEC Display Solutions of America Inc QIG TMXP 46UN X463UN TMX4P Rev 1 1 main menu icon Under the TileMatrix sub menu enable the feature and set the necessary parameters that match the 2x2 Video Wall setup Note that this step will need to be completed for each screen 8 select if TileComp is necessary for this application or not TileComp works in tandem with TileMatrix to compensate for the width of the
5. tiled bezels in order to accurately display the image Click YES on enable to display video wall Note that this step will need to be completed for each screen TILE MATRIX H MONITORS 2 V MONITORS 2 POSITION 1 TILE COMP YES NO ENABLE YES NO AT stent A SET HTA E EXIT MATAR MENU HH OR If you are experiencing issues with this setup please call our Technical Support number at 800 632 4662