1. SENSE RUN MB B21 B11 D1 ALM1 B20 B10 DO ALMO NEAX2000 IVS ISDN System Manual ND 70919 E Issue 1 0 Page 151 CHAPTER 4 CIRCUIT CARD INFORMATION PN 2BRTC BRT Lamp Indications FUNCTION Flashes at 120 IPM while this card is operating normally No 1 Circuit B2 channel status ON Busy OFF Idle Flash 60 IPM Make Busy B1 channel status ON Busy OFF Idle Flash 60 IPM Make Busy D channel status ON Busy OFF Idle Transmission line fault status ON Line fault OFF Normal operation No 0 Circuit B2 channel status ON Busy OFF Idle Flash 60 IPM Make Busy B1 channel status ON Busy OFF Idle Flash 60 IPM Make Busy D channel status ON Busy OFF Idle Transmission line fault status ON Line fault OFF Normal operation NEAX2000 IVS ISDN System Manual Page 152 ND 70919 E Issue 1 0 CHAPTER 4 CIRCUIT CARD INFORMATION PN 2BRTC BRT Switch Settings SWITCH SETTING SWITCH NAME NUMBER POSITION FUNCTION SENS Set the switch to match the AP Number 04 31 to Rotary SW be set by 5 SW11 4 ON SW11 4 OFF SW No AP No MB Toggle SW AS For make busy NOTE 2 For normal operation SWO
2. APO06 SLOT 07 SLOT 8 SLOT LTC3 9 SLOT AP10 SLOT AP11 SLOT NEAX2000 IVS ISDN System Manual ND 70919 E Issue 1 0 Page 45 CHAPTER 2 INSTALLATION Installation Procedure for ISDN PRI AP05 Figure 2 5 Example of MDF Cross Connection for DTI PRT LTC1 DTI PRT J P MDF P s RA P RA RB RB TA P TA TONN TB B TB NUM LTC1 J LTC1 P Page 46 NEAX2000 IVS ISDN System Manual ND 70919 E Issue 1 0 CHAPTER 2 INSTALLATION Installation Procedure for ISDN PRI Cable Connection via CONN Card When you use a coaxial cable connect the cable to a NT1 equipment via the CONN PZ M542 PZ M557 card as shown in Figure 2 6 Figure 2 7 shows an example of the cable connection when the DTI PRT card is mounted on the APO5 slot of PIMO Figure 2 6 Cable Connection via the CONN Card BWB NT1 COAXIAL CABLE CONN LTCO LTC1 LTC2 LTC3 CONNECTOR MAX 6 dB loss at 1024 kHz NEAX2000 IVS ISDN System Manual ND 70919 E Issue 1 0 Page 47 CHAPTER 2 INSTALLATION Installation Procedure for ISDN PRI AP05 Figure 2 7 Example of Coaxial Cable Connection PIM O DTI PRT D LTC1 CON
3. 47 Figure 2 7 Example of Coaxial Cable Connection 48 Figure 2 8 installation Procedure for ISDN BRI joni sinc cides deren 49 Figure 2 9 BRT Cable Connection via MDF OG EA RA 51 Figure 2 10 Location of AP Slots and LTC Connectors for 52 Figure 2 11 Example of MDF Cross Connection for BRT 1 of 2 53 Figure 2 11 Example of MDF Cross Connection for BRT 2 2 54 Figure 2 12 Installation Procedure for ISDN Terminal 55 Figure 2 13 ILC Cable Connection via MDF XA ons 58 Figure 2 14 Location of LT Slots and LTC Connectors for ILC 59 Figure 2 15 Example of MDF Cross Connection for ILC 60 Figure 2 16 Installation Procedure for Event Based CCIS 61 Figure 3 1 Outline of BRI to BRI Connections 2 2 eseeeee be eeeeeeseeevevse eeu 115 Figure 3 2 Event Based COIS Programming Summary ausis sss y REA ORE ERA RARE RR ER Gra 116 Figure 3 3 Verification of DODDSBIIT i ihe 127 Figure 4 1 Mounting Location of Circuit Card 400 Quad Vukaad cat Ee 139 NEAX2000 IVS ISDN System Manual Page iv ND 70919 E Issue 1 0 Table Table 1 1 Table
4. NOTE 4 When the PBX is a clock source office set the SWO 1 SWO 2 on all the PRT cards mounted in PIMO to OFF NOTE 5 Mount the PRT card which receives a source clock signal into PIM 0 NEAX2000 IVS ISDN System Manual ND 70919 E Issue 1 0 Page 173 CHAPTER 4 CIRCUIT CARD INFORMATION PN SC00 CCH PN SC00 CCH Locations of Lamps Switches and Connectors SENSE RUN MB SWO LC LPB RS TO MODEM FOR ANALOG INTERFACE Lamp Indications FUNCTION Flashes at 120 IPM while this card is operating normally Remains lit when communications are normally ongoing with the common signalling channel data links connected Remains lit when a loop back test is in progress NEAX2000 IVS ISDN System Manual Page 174 ND 70919 E Issue 1 0 CHAPTER 4 CIRCUIT CARD INFORMATION PN SC00 CCH Switch Settings SWITCH SWITCH SETTING NAME NUMBER POSITION SENS Set the switch to match the AP Number 04 31 to Rotary SW be set by 5 SWO 4 AP No Y SWO 4 OFF SW No NOTE 1 MB Toggle SW ST For make busy NOTE 2 For normal operation SWO Loop back test Piano Key SW For normal operation OFF Analog interface Digital interface RS 232C RTS signal to MODEM ON NOTE 3 RS 232C RTS signal to MODEM OFF AP No 04 15
5. SWITCH NUMBER SETTING POSITION FUNCTION Source clock signal from network is sent to the PLOO input on MP card Source clock signal from network is not sent to the PLOO input on MP card Source clock signal from network is sent to the PLO1 input on MP card Source clock signal from network is not sent to the PLO1 input on MP card Remote loop back For normal operation Local loop back AIS send For normal operation Set equalizer according to the cable length between the PBX and the MDF 5 SW0 6 SW0 7 CABLE LENGTH 0 40 m 0 131 2 ft 40 80 m 131 2 262 5 ft 80 120 m 262 5 394 ft 120 160 m 394 525 ft 160 200 m 525 656 ft Signal is not sent Not used Continued NEAX2000 IVS ISDN System Manual ND 70919 E Issue 1 0 Page 159 CHAPTER 4 CIRCUIT CARD INFORMATION PN 24DTA C DTI SWITCH NAME Swi Piano Key SW OFF 3 ON NOTE 4 SWITCH NUMBER SETTING POSITION FUNCTION Not used Not used Not used AP No 04 15 AP No 20 31 JPRO Jumper Pin Neutral grounding the receiving line is provided Neutral grounding on the receiving line is not provided JPR1 Jumper Pin EES Line impedance 100 ohms Line impedance 110 ohms JPS Jumper Pin Ne
6. 39 ISDN PRI Required Equipment cass 39 ISDN BRI Required ESUIBInBM ucuekeeuicuERUA e ER be 39 ISDN Terminal Required Equipment RR 40 Event Based CCIS Required Equipment 40 INSTALLATION PROCEDURE FOR IBDB PPIL 15224429261 VE rar riie nio ER RR RE 41 Mounting DTI and DCH Car Card sweets eins ke rs 42 Mounino CONN CaA eaa estates ed 43 DTI PRT Cable Connection via 44 Cable Connection via CONN Gard 47 INSTALLATION PROCEDURE FOR ISDN BRI RR 49 Mourning BRI Card 50 BRT Gable Connection via MDF 51 INSTALLATION PROCEDURE FOR ISDN TERMINAL 2 55 me 56 Cat OR RUP Pire REESE RN ERE ELEM LP CURL LE EM 57 ILC Cable Done dh via MDF 58 INSTALLATION PROCEDURE FOR EVENT BASED ananunua sau 61 Mounting COCH Card HEAR bade a Kx Rocca ad 62 GHAPIERS SYSTEM DATA PROGRAMMING 246i 2225459 a 63 HOW TO READ THIS CHAPTER 224a ERE Bibi Em eh 64 ISDN PRI PROGRAMMING RR EAE ER CORRER P 65 Digital I
7. AP No 20 31 Continued NEAX2000 IVS ISDN System Manual ND 70919 E Issue 1 0 Page 175 CHAPTER 4 CIRCUIT CARD INFORMATION PN SC00 CCH SWITCH SWITCH SETTING NAME NUMBER POSITION SW1 DIP SW Common channel signalling data transmission speed For Digital FUNCTION ON Mu 3 8 2567 Interface n TaN 56 Kbps 64 Kbps Common channel signalling data transmission speed For Analog Interface Set switches SW1 1 SW1 5 to OFF A law u law Always set to OFF Always set to OFF The figure in the SWITCH NAME column and the position in in the SETTING POSITION column indicate the standard setting of the switch When the switch is not set as shown by the figure and the setting of the switch varies with the system concerned NOTE 1 Set the groove on the switch to the desired position NOTE 2 When the power is on flip the MB switch to ON UP position before plugging unplugging the circuit card NOTE 3 This setting is available when SWO 2 is set to ON Analog Interface NOTE 4 The following two kind of rate adaptation methods are available in 48 Kbps data transmission The rate adaptation method must be set to match the rate adaptation of master office SW1 3 OFF SW1 3 ON 48 Kbps 48 Kbps 1 1
8. PRT card CMAA YY 00 01 02 assign ment is required only for 24DTI PRT DTI INITIAL After entering the data set the MB switch on the DTI PRT card to UP and then to DOWN for DTI PRT initialization NOTE The following table shows the relationship between CMAA YY 01 and YY 02 CMAA YY 02 ZERO CODE SUPPRES SION CMAA YY 01 FRAME CON FIGURATION SIGNALING 24 Multi Frame 1 12 Multi Frame Not available 1 Transparent 0 Available 0 B7 Indicates 2nd data B8ZS Assign a trunk route number to each ISDN trunk used for voice channel and also to signaling channel The DTI route must be separated from any analog trunk route Assign the trunk route data to each ISDN incoming trunk used for Voice channel only DATA YY 00 Data Mode 04 15 20 31 AP No assigned by CMO05 0 Based on AT amp T Spec YY 01 Frame Configuration 04 15 20 31 AP No assigned by CMO05 0 12 Multi Frame 1 lt q 24 Multi Frame YY 02 Zero Code Suppression 04 15 20 31 AP No assigned by CMO05 0 Available 1 lt q Not available YY 03 04 15 20 31 AP No assigned by CM05 7 Associated Channel Interoffice Signaling YY 00 000 255 Trunk No assigned by CMO7 YY 01 00 63 Trunk Route No YY 02 Day Mode YY 03 Night Mode YY 40 Mode A YY 41 Mode B 000 255 Trunk No assigned by CM07 YY 01 02 Trunk Line Appearance 03 Trunk Line Appearance TAS 04 Direct In Termination
9. SWO 2 to OFF BRT card SWO 2 and SWO0 3 to OFF e 2BRT card SW11 2 and SW11 3 to OFF The CLK lamp on the MP card goes out STEP 2 Originate an outgoing call via trunks STEP 3 After an outgoing connection via trunks has been established confirm interoffice synchronization and speech quality as follows On the DTMF telephone set keep pressing any dial button Check to see if noise periodically occurs on the DTMF signals coming from the calling station in the opposite office Do the above test again in the opposite direction STEP 4 On all the DTI PRT BRT cards mounted in PIMO restore the switches as the state before testing to input the external clock signals The CLK lamp on the MP card lights NOTE If noise periodically occurs replace the MP card after checking the switch settings on the MP card and do the above test again NEAX2000 IVS ISDN System Manual ND 70919 E Issue 1 0 Page 195 CHAPTER 5 OPERATION TEST PLO Operation Test Clock Signal Synchronization Test This test checks to see if the PLO keeps synchronizing with the external clock signals when the external clock signals from network has input again after it has stopped once Do the following procedure using In Service transmission lines 1 When providing one clock supply route STEP 1 STEP 2 STEP 3 STEP 4 STEP 5 On the DTIO PRTO BRTO card extracting clock signals set the switches as follows to stop the ex
10. 07 SLOT 8 SLOT LTC3 9 SLOT AP10 SLOT AP11 SLOT Page 52 NEAX2000 IVS ISDN System Manual ND 70919 E Issue 1 0 CHAPTER 2 INSTALLATION Installation Procedure for ISDN BRI Figure 2 11 Example of MDF Cross Connection for BRT 1 of 2 AP05 LTC1 PN BRTA P MDF P s RA P RA RB RB v TA P pa TOATI TB B TB QNUM LTC1 J LTC1 P NEAX2000 IVS ISDN System Manual ND 70919 E Issue 1 0 Page 53 CHAPTER 2 INSTALLATION Installation Procedure for ISDN BRI Figure 2 11 Example of MDF Cross Connection for BRT 2 of 2 PIMO LTC1 PN 2BRTC MDF A RA RB No 0 lt 7 CIRCUIT ta HERES TB AP05 4 RA RB No 1 n TO NT1 CIRCUIT P TA P B TB LTC1 J LTC1 P NEAX2000 IVS ISDN System Manual Page 54 ND 70919 E Issue 1 0 CHAPTER 2 INSTALLATION Installation Procedure for ISDN Terminal INSTALLATION PROCEDURE FOR ISDN TERMINAL Install the equipment for the ISDN Terminal according to the procedure shown in Figure 2 12 Figure 2 12 Installation Procedure for ISDN Terminal Mounting ICH Card See Page 56 Mounting ILC Card See Page 57 ILC Cable Connection See Page 58 NEAX2000 IVS ISDN System Ma
11. Assign the LCR Group key on the if required Assign an Area Code Development Pattern number to each LCR Group Assign a Route Pattern number to each area code for the Area Code Development Pattern number assigned by YYYY A000 Specify the order of LCR selection for the Route Pattern number assigned by YYYY 4000 4007 For area code addition designate the digits to be added DATA Y 0 3 Number Plan Group 0 3 X XXXX Access Code A126 LCR Group 0 A127 LCR Group 1 A128 LCR Group 2 A129 LCR Group 3 YY 00 My Line No Key No FOA26 LCR Group 0 FOA27 LCR Group 1 FOA28 LCR Group 2 YYYY A000 0 3 LCR Group 0 3 4000 4007 Area Code Development Pattern No 0 7 YYYY 4000 4007 Area Code Development Pattern No 0 7 X X Area Code Max 8 digits 0000 0255 Route Pattern No 000 255 YYYY 0000 0255 Route Pattern No 000 255 1 4 Order of LCR Selection 1 1st 2 2nd 3 3rd 4 4th XXX ZZ XXX 000 255 LCR Pattern No ZZ 00 63 Trunk Route No YYYY 5000 5255 100 Designation of digit Addition Pattern No 9000 9255 Digit Addition Pattern No 000 255 CCC No digit addition NEAX2000 IVS ISDN System Manual ND 70919 E Issue 1 0 Page 99 CHAPTER 3 SYSTEM DATA PROGRAMMING ISDN VPN Programming END DESCRIPTION To delete the designated digit of an area code assigned by YYYY 4000 4007 Assign the sending an area code to ISDN as a Called Party Subaddress
12. EIE en EORR ee re eam er eod eee ere ee PNSCOS ICH rd RE REL RAS 180 ipee Recht SQUE LIV qi O da 182 ee CONN eh oh Ab Loe ees Lad oe EIE Mu esM d 184 FEIDEILDR ULIS girit neni aimi etic tice teeth boule ports ra Eden OE 186 GHAPTER S OPERATION TEST paidin 189 INTEROFFICE TRANSMISSION LINE TEST EP RES ES 190 PLO OPERATION TESI ORAR AEREA KATADE RINER R 195 Clock Signal Generation Test tiam qx 195 Clock Signal Synchronization Test FI ECRIRE 196 Interoffice Synchronization Test RR 198 Source Des Mode TSG 4142 4E RO Erra RENATA edo OE 199 NEAX2000 IVS ISDN System Manual ND 70919 E Issue 1 0 Page iii LIST OF FIGURES Figure Title Page Figure 1 1 System Outline of ISDN PRI uoa ue b T Ede ERRLEEPERTEESU ERRORES UL enin 4 Figure 1 2 System Outline of ISDN BRI bean 5 Figure 1 3 Example of ISDN VPN 1 of 2 FERRE 6 Figure 1 3 Example or ISDN YPN 2 OI 2 iac kD RE 7 Figure 1 4 System Outline of ISDN Terminal for ISDN PRI 8 Figure 1 5 System Outline of ISDN Terminal for ISDN BRI 9 Figure
13. 09 Automated Attendant 14 Termination to Attendant console 16 Remote Access to System DISA 18 ISDN Indial Page 66 NEAX2000 IVS ISDN System Manual ND 70919 E Issue 1 0 CHAPTER 3 SYSTEM DATA PROGRAMMING ISDN PRI Programming DESCRIPTION Assign Circuit Identification Code CIC number to each ISDN trunk used for voice channel only NOTE CIC No must not be assigned to the trunk No of D channel TS16 SODTI or TS23 24DTI PRT Assign trunk route data to the route number assigned by CM30 YY 00 DATA YY 07 1 000 255 Trunk No assigned by CM07 YY 01 2 000 029 CIC No EXAMPLE OF 30DTI B channel trunk No D100 D114 D116 D130 D channel trunk No D115 1 100 114 116 130 2 000 014 015 029 EXAMPLE OF 24DTI PRT B channel trunk No D100 D122 D channel trunk No D123 1 100 122 2 000 022 YY 00 Kind of Trunk Route 1 00 63 B channel Trunk Route No 2 00 ISDN Trunk 1 00 63 D channel Trunk Route No 2 15 Not used e YY 02 Call Direction 1 00 63 B channel Trunk Route No 2 3 lt q Bothway Trunk NOTE 1 e YY 04 Answer Signal from distant office 1 00 63 B channel Trunk Route No 2 2 Answer signal arrives ISDN Trunk 1 00 63 D channel Trunk Route No 2 7 lt q Not used NEAX2000 IVS ISDN System Manual ND 70919 E Issue 1 0 Page 67 CHAPTER 3 SYSTEM DATA PROGRAMMING ISDN PRI Programming g DESCRIPTION DATA e YY
14. CAUTION You must hold the edge of a circuit card when plugging or unplugging the circuit card If you touch another area you may be exposed to hazardous voltages NEVER TOUCH THE COMPONENTS n OR SOLDERED SURFACE WITH BARE HANDS m CARD FRONT NEAX2000 IVS ISDN System Manual Page 38 ND 70919 E Issue 1 0 CHAPTER 2 INSTALLATION Required Equipment REQUIRED EQUIPMENT ISDN PRI Required Equipment Table 2 1 shows the equipment required to provide ISDN with Primary Rate Interface to the system EQUIPMENT PN 24DTA C 24 DTI Table 2 1 ISDN PRI Required Equipment QUANTITY DESCRIPTION 24 channel DTI Card REMARKS PN 24PRTA PRT 24 channel PRT Card PN 30DTC A 30 DTI 30 channel DTI Card PN SCO1 DCH D Channel Handler Card 1 DTl card PZ M542 M557 CONN Connection Card for Coaxial Cable ISDN BRI Required Equipment Table 2 2 shows the equipment required to provide ISDN with Basic Rate Interface to the system EQUIPMENT PN BRTA BRT As required 1 DTl card Max 3 per PIM Table 2 2 ISDN BRI Required Equipment DESCRIPTION 1 line BRT Card QUANTITY REMARKS PN 2BRTC BRT 2 line BRT Card NEAX2000 IVS ISDN System Manual ND 70919 E Issue 1 0 Page 39 CHAPTER 2 INSTALLATION Required Equipment ISDN Terminal Required Equipment Table 2 3 shows the equipment required to provide IS
15. CM8A400522 dialed number 001 go to route pattern 000 CM8A0000 gt 1 15t choice 00210 use LCR pattern 002 trk route 10 CM855 gt 2 7 maximum number of digits dialed CM8A5002 gt 157 04 Kind of called party Local dialed number is 7 digit NANP select Local CM8A5002 gt 158 01 Called party Number Plan ID ISDN Telephony Numbering Plan CM8A5002 gt 159 161 are not used for this call CM8A5002 gt 162 1 Service CM8A5002 gt 163 NONE not sending CM8A5002 gt 164 is not required for this call NOTE These examples are provided to demonstrate the required programming Always verify with the ISDN provider as to how local calls should be handled Features Carrier Identification Codes CIC In ISDN terms placing a long distance call using the equal access carrier code is a feature There are times when depending upon the type of service provider LEC or IEX the PBX must contain the following programming to complete a long distance call by using CIC numbers Currently all CIC numbers are three digits in length preceded by a 10 Example To dial AT amp T a user dials 10288 the long distance number The PBX must route the call based on 10288 ora portion of that number ISDN complicates this process by identifying each CIC at the PBX level For example Without ISDN the PBX is able to simply outpulse 10288 and the public network would provide connection to AT amp T With ISDN used for routing equal access calls the PBX must translat
16. 00 63 Outgoing Trunk Route 2 0 Allowed 1 lt q Restricted CMO08 Tandem connection by station or 1 028 Miu 2 0 Available 1 lt q Not available NOTE The Home Side Virtual Tie line routes must be included for all Tandem combinations END NEAX2000 IVS ISDN System Manual ND 70919 E Issue 1 0 Page 135 CHAPTER 3 SYSTEM DATA PROGRAMMING Event Based CCIS Programming Closed Numbering Plan Programming START DESCRIPTION DATA CM8A Assign LCR Group number to Area Code e YYYY A000 Development Pattern 1 0 3 LCR Group No 2 4000 4007 Area Code Development Pattern No Assign Area Code Development Pattern e YYYY 4000 4007 number 1 X XXX Area Code Max 8 digits 2 0000 0255 Route Pattern No Assign Route Pattern e YYYY 0000 0255 1 1 4 1st 4th Order 2 XXX ZZ XXX 000 255 LCR TR Pattern No ZZ 00 63 Trunk Route No Assign maximum number of sending e Yz0 7 Area Code Development Pattern digits No 0 7 1 X XX Area Code Max 8 digits 2 01 79 Max number of sending digits END NEAX2000 IVS ISDN System Manual Page 136 ND 70919 E Issue 1 0 CHAPTER 4 CIRCUIT CARD INFORMATION This chapter explains the mounting location the meaning of lamp indications and the method of switch settings of each circuit card for the ISDN system NEAX2000 IVS ISDN System Manual ND 70919 E Issue 1 0 Page 137 CHAPTER 4 CIRCUIT CARD INFORMATION How to Read This Chapter
17. Always set to OFF Always set to OFF Always set to OFF Always set to OFF The figure in the SWITCH NAME column and the position in in the SETTING POSITION column indicate the standard setting of the switch When the switch is not set as shown by the figure and the setting of the switch varies with the system concerned NOTE 1 Set the groove on the switch to the desired position NOTE 2 When the power is on flip the MB switch to ON UP position before plugging unplugging the circuit card NEAX2000 IVS ISDN System Manual ND 70919 E Issue 1 0 Page 179 CHAPTER 4 CIRCUIT CARD INFORMATION PN SCO3 ICH PN SCO03 ICH Locations of Lamps Switches and Connectors SENSE RUN MB DOPE7 DOPE6 DOPES5 DOPE4 DOPE3 DOPE2 DOPE1 DOPEO 00000000 Lamp Indications FUNCTION Flashes at 120 IPM while this card is operating normally Remains lit when No 7 circuit D channel link is connected Remains lit when No 6 circuit D channel link is connected Remains lit when No 5 circuit D channel link is connected Remains lit when No 4 circuit D channel link is connected Remains lit when No 3 circuit D channel link is connected Remains lit when No 2 circuit D channel link is connected Remains lit when No 1 circuit D channel link is connected Remains lit when No O circuit D channel link is connected N
18. DTI do the following programming DESCRIPTION Specify whether the busy tone is sent to a calling party of ISDN when a called party is busy in the tandem connection ISDN to COT Specify the combination of trunk routes allowing the tandem connection Specify the timing start when making an ISDN call from a station PB DP telephone Dte or Attendant Console for the Tandem Connection DATA 1 407 2 0 Available BT 1 lt q Not available RBT e Y 0 1 XX ZZ XX 00 63 Incoming Trunk Route ZZ 00 63 Outgoing Trunk Route 2 O Allowed 1 lt q Restricted e Y 0 1 57 2 03 14 3 sec 14 sec If no data is set the timing start is not effective NOTE 1 By using CM41 Y 0 gt 57 an ISDN call is available even if is not dialed NOTE 2 CM41 Y 0 gt 57 is effective for dialing a called number When dialing a called party subaddress this command is not effective Page 80 NEAX2000 IVS ISDN System Manual ND 70919 E Issue 1 0 CHAPTER 3 SYSTEM DATA PROGRAMMING ISDN BRI Programming When providing Tandem Connection ISDN to CCIS CCIS to ISDN do the following programming CM36 END DESCRIPTION Specify the combination of trunk routes allowing the tandem connection Allow tandem connection by station or attendant DATA e Y 0 1 XX ZZ XX 00 63 Incoming Trunk Route ZZ 00 63 Outgoing Trunk Route 2 O Allowed 1 lt q Restricted 1 028 2 0 Available e
19. HOW TO READ THIS CHAPTER This chapter explains each circuit card used in this system Explanations are given in alphabetical order of the circuit card names within each circuit card category Control Application Processor and Line Trunk 1 Locations of Lamps Switches and Connectors The locations of lamps switches and connectors of each circuit card are shown by a face layout 2 Lamp Indications The name color and functions of each indicator lamp equipped on each circuit card are described in a table 3 Switch Settings The name settings and functions of each switch equipped on each circuit card are described in a table Each switch setting table has a CHECK column Make necessary entries in the CHECK column during and or after the system installation and maintenance and use each table as a reference for subsequent system maintenance and operations NEAX2000 IVS ISDN System Manual Page 138 ND 70919 E Issue 1 0 CHAPTER 4 CIRCUIT CARD INFORMATION Mounting Location of Circuit Card MOUNTING LOCATION OF CIRCUIT CARD This section explains the conditions for mounting circuit cards for the ISDN system Figure 4 1 shows circuit card mounting slots allocated in the PIM Figure 4 1 Mounting Location of Circuit Card 13 00dV 00 L1 LOdV LOLT ce0dV c0 L1 0dV 0 L1 vOdV vOl1 S0dV S01 909 9011 409 011 80 8011 60dV 60111 OLdV OLL1 c Ldd cLdW LEda EEdv ELET FRONT 1
20. PN BRTA BRT Switch Settings SWITCH SETTING SWITCH NAME NUMBER POSITION FUNCTION SENS Set the switch to match the AP Number 04 15 to Rotary SW be set by 5 G AP No 04 05 06 07 08 09 10 11 12 13 14 15 4 5 6 7 8 9 NOTE 1 0 3 Not used MB Toggle SW A 1 For make busy NOTE 2 For normal operation SWO DIP SW For normal operation T Not used Source clock signal from network is sent to the PLO of MP according to the switch setting of SWO 3 Source clock signal from network is not sent to the PLO of MP card Clock signal is sent to the PLOO of MP Clock signal is sent to the PLO1 of MP For normal operation Not used Continued NEAX2000 IVS ISDN System Manual Page 148 ND 70919 E Issue 1 0 CHAPTER 4 CIRCUIT CARD INFORMATION PN BRTA BRT SWITCH SETTING SWITCH NAME NUMBER POSITION FUNCTION SW1 DIP SW For terminating the transmitting side on of channels B1 and B2 with 100 5 1 ohms To remove the terminating resistor OFF on the transmitting side of channels B1 and B2 ON For terminating the receiving side of CON channels B1 and B2 with 100 ohms To remove the terminating resistor OFF on the receiving side of channels B1 and B2 Contin
21. 0 CHAPTER 3 SYSTEM DATA PROGRAMMING ISDN BRI Programming CM76 DESCRIPTION When the data for CM35 YY 18 is set to 0 Received digits conversion is to be provided assign the data for interpreting the digits received DATA YYz01 Day Mode e YYz02 Night Mode YYz03 Mode YYz04 Mode B 1 000 999 Number Conversion Block No assigned by CM76 Y 00 2 X XXXXXXXX Station No to be terminated DXX Change Terminating System to 009 Automated Attendant D14 Attendant Console D16 Remote Access to System DISA For originating calls to the ISDN network do the following programming DESCRIPTION Assign ISDN access code to each trunk route assigned by CM30 YY 00 Specify the timing start when making an ISDN call from an attendant Specify the timing start when making an ISDN call from a Single Line Telephone PB DP D or Attendant Console if required DATA Yz0 3 Numbering Plan Group 0 3 1 X XXXX Access code 2 100 163 Trunk Route 00 63 1 403 2 0 Not available 1 lt q Available e Y 0 1 50 2 03 14 3 sec 14 sec If no data is set the timing start is not effective Dialing terminated by entering Recommended setting is 05 5 seconds NEAX2000 IVS ISDN System Manual ND 70919 E Issue 1 0 Page 79 CHAPTER 3 SYSTEM DATA PROGRAMMING ISDN BRI Programming When providing Tandem Connection COT ODT LDT DTI to ISDN ISDN to COT ODT LDT
22. 1 2 Table 1 3 Table 1 4 Table 1 5 Table 1 6 Table 1 7 Table 1 8 Table 2 1 Table 2 2 Table 2 3 Table 2 4 Table 4 1 Table 5 1 Table 5 2 Table 5 3 Table 5 4 LIST OF TABLES Title Page Event Based CCIS sau cunc o Luke Sardo a e Cid o Ee ES EP od 17 ISDN Card Mame and Function isses ule RR LER RIA VRRRREEDRERIERT ERR 21 System Capacity for IGDN PRI bad bah duke 22 System Capacity for ISDN BRI v nes 23 Transmission Characteristics irae d dA cede earns AR RAO ERROR RR ENE SRE cheer 27 12 Multi Frame Bit Assignment psc idee or 30 24 Multi Frame BR 36 6565 4 6504 32 Time Slot Assignment or SUDTI a iocus abrigo diced 34 ISDN PRI Required Equipment icu RR RRIRRRERRE EE RR ETRERRERREIA 39 ISDN BRI Bedilred Eguibimeht 39 ISDN Terminal Required Equipment ca Rd 40 Event Based CCIS Required Equipment 40 Lit of Required Circ it Card Rh RR 140 Alam Indications on 24DTI Rm ERE RR RE RR ERR EEG 191 Alana indiens on SUDTI 4s ca 192 Alam Indications on 24PRT 193 Alam indications on BRI dd oe ev v odes 194 NEAX2000 IVS ISDN System Manual ND 70919 E Issue 1 0 Page v This page is for your notes NEAX2000 IVS ISDN System Manual Pag
23. 1 8 Clock Supply GUIS EE EAR EA RAO EROR EROR GO ARR ROC RR 12 Figure 1 7 System Outline of Event Based CCIS 14 Figure 1 8 Release Timing of Virtual Tie Line and CCIS 15 Figure 1 9 iit 2 4245 44 54 465s 50teecrstdegGaridicisiebectad sgtaniaeeneian 16 Figure 1 10 Accommodation of DTI DCH ICH BRT PRT into TDSW 24 Figure 1 11 Time Slot Alleestion for DTI Luise CEA OPER OR oho iw KES Rd 25 Figure 1 12 Line Distance Between PBX and NT1 ISDN Terminal 26 Figure 1 13 DTI Frame Configuration 12 Multi Frame 29 Figure 1 14 DTI Frame Configuration 24 Multi Frame 31 Figure 1415 Frame Contiquration or SUDTI eni los lee vie RR ERRARE ERE 33 Figure 2 1 Static Electricity Guard LT O62 vase KR TVA SERERE NR 36 Figure 2 1 Stans Electricity GUIO DS OE naan cies dhe Ka ROO e EEI RPT ROR ER 36 Figure 2 2 Installation Procedure tar ISDN PRI RR 41 Figure 2 3 DTI PRT Cable Connection via MDF Leak REY 44 Figure 2 4 Location of AP Slots and LTC Connectors for DTI PRT 45 Figure 2 5 Example of MDF Cross Connection for 46 Figure 2 6 Cable Connection via the CONN Card
24. 70919 E Issue 1 0 Page 15 CHAPTER 1 GENERAL INFORMATION Outline of Event Based CCIS For Event Based CCIS the virtual trunks are used as a No 7 CCIS trunk Virtual Trunk The virtual trunk consists of a Home Side Trunk and a Mate Side Trunk The Home Side Trunk is connected to the station side and the Mate Side Trunk is connected to the network side of the PBX virtually The virtual trunks do not exist actually but are handled as a No 7 CCIS trunk by the system for system data ISDN subaddress or ISDN indial number is used to notify the CCIS channel number for virtual tie line and establish a CCIS link and individual voice links between offices Figure 1 9 VirtualTrunk DTI BRT PRT 7 MATE SIDE VIRTUAL TRUNK 4 HOME SIDE SIDE CCH Card The CCH card is used to handle the common channel signaling TDSW DTI BRT PRT Card The system uses the same interface trunk for regular ISDN connection and the virtual tie line connection on Event Based CCIS ISDN Protocol Analyzer For ISDN PRI the protocol analyzer must be able to support ISDN exchange such as AT amp T Nortel For North America it must support National ISDN 2 NI 2 protocols For ISDN BRI the protocol analyzer must be an S T interface For North America it must support National ISDN 1 NI 1 protocol Both analyzers must be capable of collecting Layer 2 and Layer 3 Q921 amp Q931 information NEAX2000 IVS ISDN System Manual Page 16
25. AP number assigned by 5 INITIAL DATA Y 0 04 15 AP No 13 ICH card YY 09 00 15 ICH No 04 15 AP No assigned by CM05 YY 00 XX Z XX 00 15 ICH No Z 0 7 ISDN Line No of ICH card X XXXXXXXX ISDN Line Station No YY 02 XX Z XX 00 15 ICH No Z 0 7 ISDN Line No of ICH card 0 Manual TEI Assignment 1 lt q Automatic TEI Assignment YY 04 XX Z XX 00 15 ICH No Z 0 7 ISDN Line No of ICH card 0 Always activated 1 lt q Activated by call event YY 06 04 15 AP No of ICH assigned by CMO05 24 ETSI Terminal 63 lt q Not ETSI Terminal NEAX2000 IVS ISDN System Manual ND 70919 E Issue 1 0 Page 103 CHAPTER 3 SYSTEM DATA PROGRAMMING ISDN Terminal Data Programming Point to Point Connection PBX ISDN Terminal TA MDF Max 1965 ft 600 m START DESCRIPTION Assign the point to point connection as the CMAC Layer 2 data link ILC 1 2 DATA YY 01 XX Z XX 00 15 ICH No Z 0 7 ISDN Line No of ICH card 0 Point to Point Connection NOTE When Point to Point Connection is selected the PBX will address the BRI Terminal with channel select B1 B2 message Some BRI Terminals cannot answer the call with this type of signaling Some of the BRI Terminals require a Calling Party Number sent from the PBX In this case use Point to Multipoint for CMAC YY 01 and CM1B to assign extension number for the BRI Terminal Assign the Ma
26. CARD INFORMATION PN 24DTA C DTI Lamp Indications FUNCTION Flashes at 120 IPM while this card is operating normally Remains lit when detecting Cyclic Redundancy Checking CRC errors Remains lit when detecting PCM signal loss Remains lit when detecting Frame Alignment signal loss Remains lit when receiving Frame Alignment signal loss alarm from a distant office Remains lit when a pattern of consecutive 1 is received The distant office transmits this signal for a loop back test B channel status ON More than 10 channels are busy OFF All channels are idle Flash 60 IPM Only one channel is busy Flash 120 IPM 2 through 10 channels are busy NEAX2000 IVS ISDN System Manual ND 70919 E Issue 1 0 Page 157 CHAPTER 4 CIRCUIT CARD INFORMATION PN 24DTA C DTI Switch Settings SWITCH NAME SENSE Rotary SW SWITCH SETTING NUMBER POSITION Not used FUNCTION SW1 4 ON AP No Set the switch to match the AP Number 04 31 to be set by 5 SW1 4 OFF SW No MB Toggle SW af For make busy For normal operation Continued Page 158 NEAX2000 IVS ISDN System Manual ND 70919 E Issue 1 0 CHAPTER 4 CIRCUIT CARD INFORMATION PN 24DTA C DTI SWITCH NAME SWO Piano Key SW NUAR
27. Call Identification CCIS Individual Attendant Access CCIS LDN Night Connection CCIS Link Alarm Display CCIS Message Waiting Lamp Setting Attendant CCIS Message Waiting Lamp Setting Station CCIS Miscellaneous Trunk Access CCIS Miscellaneous Trunk Restriction CCIS Multiple Call Forwarding All Calls CCIS Multiple Call Forwarding Busy Line CCIS Multiple Call Forwarding Don t Answer CCIS Night Connection Fixed CCIS Night Connection Flexible CCIS Outgoing Trunk Queuing CCIS X X X X X X X X X Paging Access CCIS Restriction from Outgoing Calls CCIS Single Digit Station Calling CCIS Station Controlled Conference CCIS Station to Station Calling CCIS Station to Station Calling Operator Assistance CCIS Toll Restriction 3 6 Digit CCIS Trunk Answer from Any Station CCIS Trunk to Trunk Restriction CCIS X X X XK xXx x NEAX2000 IVS ISDN System Manual Page 18 ND 70919 E Issue 1 0 CHAPTER 1 GENERAL INFORMATION Outline of Event Based CCIS Table 1 1 Event Based CCIS Feature List Continued X Available Not available SERVICE FEATURE AVAILABILITY REMARKS Uniformed Numbering Plan CCIS Voice Call CCIS Voice Mail Integration CCIS NOTE 1 The voice channel and the common signaling channel keep connecting after the calls finish according to the release timer data Therefore while the CCIS link
28. For coaxial connectors No 2 circuit For champ connector LT connector No 2 circuit The figure the SWITCH NAME column and the position in C 2 in the SETTING POSITION column indicate the standard setting of the switch When the switch is not set as shown by the figure and C 5 the setting of the switch varies with the system concerned NEAX2000 IVS ISDN System Manual ND 70919 E Issue 1 0 Page 185 CHAPTER 4 CIRCUIT CARD INFORMATION PN 2ILCA ILC PN 2ILCA ILC Locations of Lamps Switches and Connectors 00000 00000 ACT1 PAL1 LPB1 B21 B11 ACTO PALO LPBO B20 B10 Swi SWO Page 186 NEAX2000 IVS ISDN System Manual ND 70919 E Issue 1 0 CHAPTER 4 CIRCUIT CARD INFORMATION PN 2ILCA ILC Lamp Indications No 1 Circuit ON OFF FUNCTION Normally operating Not operating ON OFF Line is short circuiting Normally operating OFF Not used ON OFF B2 channel is in use B2 channel is idle ON OFF B1 channel is in use B1 channel is idle No 0 Circuit ON OFF Normally operating Not operating ON OFF Line is short circuiting Normally operating OFF Not used ON OFF B2 channel is in use B2 channel is idle ON OFF B1 channel is in use B1 channel is idle NEAX2000 IVS ISDN System Manual ND 70919 E Is
29. INFORMATION PN 2BRTC BRT NOTE 3 The system can supply clock signals from two clock supply routes In normal condition the system synchronizes to the clock signals supplied on the PLOO of MP card via the Back Wiring Board and if the clock signals fail the clock supply route takes over to PLO1 automatically Set SW11 2 and SW1 1 3 as follows CONDITIONS REMARKS MP card will receive the clock signal from No 0 circuit of BRTO at its PLOO input If a clock failure occurs with No 0 circuit MP card switches to No 1 circuit of BRTO When one BRT is provided MP card will receive the clock signal from BRTO at its PLOO input under normal condi When more tions than one BRT If a clock failure occurs with is provided both No 0 and No 1 circuits of BRTO MP card switches to the PLO1 input which gets clock from BRT1 NOTE 4 When the system is a clock source office set the SW11 2 and SW11 3 on all the BRT cards mounted in PIMO to OFF NOTE 5 Mount the BRT card which receives a source clock signals into PIMO NEAX2000 IVS ISDN System Manual ND 70919 E Issue 1 0 Page 155 CHAPTER 4 CIRCUIT CARD INFORMATION PN 24DTA C DTI PN 24DTA C DTI Locations of Lamps Switches and Connectors SENSE RUN MB 1005 SW Swo CRC PCM FRM RMT AIS BL co co c3 c co c NEAX2000 IVS ISDN System Manual Page 156 ND 70919 E Issue 1 0 CHAPTER 4 CIRCUIT
30. IVS ISDN System Manual Revision Sheet 1 3 ND 70919 E ISSUE No ISSUE No PAGE No PAGE No 1 2 3 4 5 6 1 4 5 6 7 8 71 1 109 1 72 1 110 1 73 1 111 1 74 1 112 1 75 1 113 1 76 1 114 1 77 1 115 1 78 1 116 1 79 1 117 1 80 1 118 1 81 1 119 1 82 1 120 1 83 1 121 1 84 1 122 1 85 1 123 1 86 1 124 1 87 1 125 1 88 1 126 1 89 1 127 1 90 1 128 1 91 1 129 1 92 1 130 1 93 1 131 1 94 1 132 1 95 1 133 1 96 1 134 1 97 1 135 1 98 1 136 1 99 1 137 1 100 1 138 1 101 1 139 1 102 1 140 1 103 1 141 1 104 1 142 1 105 1 143 1 106 1 144 1 107 1 145 1 108 i 146 1 ISSUE 1 ISSUE 2 ISSUE 3 ISSUE 4 DATE FEBRUARY 2000 DATE DATE DATE ISSUE 5 ISSUE 6 ISSUE 7 ISSUE 8 DATE DATE DATE DATE NEAX2000 IVS ISDN System Manual Revision Sheet 2 3 ND 70919 E ISSUE No ISSUE No PAGE No PAGE No 1 2 3 4 5 6 1 4 5 6 7 8 147 1 185 1 148 1 186 1 149 1 187 1 150 1 188 1 151 1 189 1 152 1 190 1 153 1 191 1 154 1 192 1 155 1 193 1 156 1 194 1 157 1 195 1 158 1 196 1 1
31. Indial number or when converting an ISDN Indial number to an ISDN Terminal station number by CM76 the system connects the call with the specified ISDN Terminal or Terminal Adapter TA on the same bus 2B D P ISDN Terminal Station No 407 y PBX Converting 7715 to 400 ISDN Line Station i 300 lt gt 214 555 7715 ISDN Indial No uw ISDN Terminal Station No 400 Do the following programming DID Addressing See Page 83 Point to Multipoint Connection See Page 105 NEAX2000 IVS ISDN System Manual ND 70919 E Issue 1 0 Page 107 CHAPTER 3 SYSTEM DATA PROGRAMMING ISDN Terminal Data Programming 2 Called Party Subaddress When the system has received a Called Party Subaddress ISDN Terminal station number from an ISDN Subscriber the system connects the call with the specified ISDN Terminal or TA on the same bus 2B D PBX ISDN Line Station No 300 Y M Y E 214 555 1111 VT TN o peso a ca ae 400 ISDN Terminal ISDN Terminal Station No 407 Station No 400 Called Party Subaddress ISDN Terminal Station No Do the following programming Subaddress Present See Page 89 Point to Multipoint Connection See Page 105 NEAX2000 IVS ISDN System Manual Page 108 ND 70919 E Issue 1 0 CHAPTER 3 SYSTEM DATA PROGRAMMING ISDN Terminal Data Programming 3 Direct In Termination DIT Whe
32. ND 70919 E Issue 1 0 CHAPTER 1 GENERAL INFORMATION Outline of Event Based CCIS Event Based CCIS Feature List Table 1 1 Event Based CCIS Feature List X Available Not available SERVICE FEATURE AVAILABILITY REMARKS Attendant Camp On with Tone Indication CCIS Attendant Controlled Conference CCIS Brokerage Hot Line CCIS Busy Verification CCIS Call Back CCIS Call Forwarding All Calls CCIS Call Forwarding Busy Line CCIS Call Forwarding Don t Answer CCIS gt lt Call Forwarding Intercept CCIS Call Forwarding Override CCIS Calling Name Display CCIS Calling Number Display CCIS Call Transfer All Calls CCIS Call Transfer Attendant CCIS Centralized Billing CCIS Centralized Day Night Mode Change CCIS Consultation Hold All Calls CCIS Deluxe Traveling Class Mark CCIS Dial Access to Attendant CCIS Direct in Termination CCIS Distinctive Ringing CCIS Do Not Disturb CCIS Dual Hold CCIS Elapsed Time Display CCIS Flexible Numbering of Station CCIS X X X X X X X X X X X X X X X X X X XxX X XxX NEAX2000 IVS ISDN System Manual ND 70919 E Issue 1 0 Page 17 CHAPTER 1 GENERAL INFORMATION Outline of Event Based CCIS Table 1 1 Event Based CCIS Feature List Continued X Available Not available SERVICE FEATURE AVAILABILITY REMARKS Hands Free Answer Back CCIS X House Phone CCIS Hot Line CCIS Incoming
33. PN SCO0 card set the MB switch to UP position and set the other switches to appropriate position See CHAPTER 4 ATTENTION Contents Static Sensitive Handlin Mount the CCH card in the following AP slots PIMO 7 APOO AP1 1 The AP11 slot on PIMO is available only when the FP card is not mounted in the FP11 slot on PIMO After mounting the card set the MB switch to DOWN position to put the card in service NEAX2000 IVS ISDN System Manual Page 62 ND 70919 E Issue 1 0 CHAPTER 3 SYSTEM DATA PROGRAMMING This chapter explains the programming procedure to provide the ISDN feature to the PBX NEAX2000 IVS ISDN System Manual ND 70919 E Issue 1 0 Page 63 CHAPTER 3 SYSTEM DATA PROGRAMMING How to Read This Chapter HOW TO READ THIS CHAPTER In the programming procedure the meaning of 1 2 and markings are as follows 1 1st Data 2 2nd Data 4 Initial Data With the system data clear command CMO00 1 the data with this marking is automatically assigned for each command CINITIAL System Initialization A reset of the MP card is required after data setting Press SW1 switch on the MP card DTI Initialization A reset of the DTI PRT card is required after data setting Set the Make Busy switch to UP and then Down DCH INITIAL DCH Initialization A reset of the DCH card is required after data setting Set the Make Busy switch to UP and then Down NEAX2
34. Restricted RCH YY 51 58 Outgoing Trunk Restriction YY 61 68 Incoming Trunk Restriction 00 63 Trunk Route No 0 Restricted 1 lt q Allowed NOTE If Call By Call Service Selection is required see Page 91 for additional programming In addition to the programming of Direct Outward Dialing assign WATS line to the required trunk route as shown below START END DESCRIPTION Assign a WATS line to the required trunk route DATA YY 00 1 00 63 Trunk Route No 2 02 WATS line NEAX2000 IVS ISDN System Manual ND 70919 E Issue 1 0 Page 85 CHAPTER 3 SYSTEM DATA PROGRAMMING ISDN Feature Programming SID to Network Present CPN to Network Present For providing the Calling Party Number CPN to the network do the following programming When Dial In service is provided DIAL 516 555 4210 516 555 4210 214 555 5000 214 555 5002 CALLING PARTY No CALLING PARTY No START DESCRIPTION Assign an ISDN Subscriber number and ISDN Local Office Code Table number to required stations NOTE 1 Specify the facility control of CPN Calling Party Number Assign ISDN Local Office Code to the Table number assigned by CM12 YY 13 END e When ISDN BRI Terminals are used START DESCRIPTION Allow the ISDN Terminal to send the CPN to network without using PBX programming DATA 12 X XXXXXXXX Station No X XXXX ISDN Subscriber No YY 13 X XXXXX
35. SW10 For terminating the transmitting side DIP SW of channels B1 and B2 with 100 ohms ON remove the terminating resistor on the transmitting side of channels B1 and B2 For terminating the receiving side of channels B1 and B2 with 100 ohms To remove the terminating resistor on the receiving side of channels B1 and B2 Continued NEAX2000 IVS ISDN System Manual ND 70919 E Issue 1 0 Page 153 CHAPTER 4 CIRCUIT CARD INFORMATION PN 2BRTC BRT SWITCH SETTING SWITCH NAME NUMBER POSITION FUNCTION SW11 DIP SW For normal operation 3 4 Not used Output clock signals according to the switch setting of SW11 3 Do not output clock signals Output clock signals to PLOO of MP Output clock signals to PLO1 of MP AP No 04 15 AP No 20 31 Continued The figure in the SWITCH NAME column and the position in in the SETTING POSITION column indicate the standard setting of the switch When the switch is not set as shown by the figure and _ the setting of the switch varies with the system concerned NOTE 1 Set the groove on the switch to the desired position NOTE 2 When the power is on flip the MB switch to ON UP position before plugging unplugging the circuit card NEAX2000 IVS ISDN System Manual Page 154 ND 70919 E Issue 1 0 CHAPTER 4 CIRCUIT CARD
36. Specifications Table 1 5 Transmission Characteristics Continued CHARACTERISTICS 24 CHANNEL 30 CHANNEL 2 Input Line Rate 1 544 Mbps 200 bps 2 048 Mbps 50 ppm 130 ppm Pulse Amplitude 1 5 volts 3 volts 1 5 volts 2 7 volts Base to Peak Coaxial Cable 1 5 volts 3 3 volts Twisted Pair Cable Frame Synchronization Pattern 001011 24MF Input Jitter ITU T Fig 1 G743 ITU T Fig 1 G743 e Wander 13801 193UI ITU T G823 or 138Ul 19301 Cable Length from PBX to NT1 Max 200 m 655 ft Max 400 m with 0 659 22 ABAM with 0 659 twisted pair cable twisted pair cable NEAX2000 IVS ISDN System Manual Page 28 ND 70919 E Issue 1 0 CHAPTER 1 GENERAL INFORMATION DTI Specifications Frame Configuration of 24DTI According to the AT amp T Specifications for 24 Channel transmission there are two types of frame configurations 12 Multi Frame and 24 Multi Frame 1 12 Multi Frame The frame has 12 Multi Frames and each Multi frame has a 24 Channel PCM signal 8 bits channel and an S bit Superframe Bit Figure 1 13 shows the frame configuration and Table 1 6 shows frame bit assignment Figure 1 13 DTI Frame Configuration 12 Multi Frame CH1 CH2 CH3 CH24 S uu ee ee 1 2 3 4 5 6 7 8 1 21314 5 6 7 8 1121314156 718 1213145 78 FRAME 1 FRAME 2 FRAME 3 FRAME 12 125 ms S Superframe Bit NEAX2000 IVS ISDN System Manual ND 70919 E Is
37. Specify the maximum number of digits to be Dialed by Calling Party The maximum number of digits including the area codes should be assigned to each area code Assign the Area Code Development Pattern number for Toll Restriction and maximum digit analysis to each trunk route DATA YYYY 9000 9025 Digit Addition Pat tern No 00 255 0 X X X Digits to be added Max 32 digits YYYY 5000 5255 153 Designation of digit to be deleted from area code assigned by YYYY 4000 4007 00 No digit deletion 01 10 Leading 1 10 digits deletion CCC No digit deletion YYYY 5000 5255 155 Designation of sending area code as a Called Party Subaddress 0 Available Y 0 7 Area Code Development Pattern No 0 7 assigned by CM8A Y A000 X X X Area code dialed Max 8 digits 01 79 1 digit 79 digits 2444 24 digits YY 76 00 63 Trunk Route No 00 07 Area Code Development Pattern No 0 7 Page 100 NEAX2000 IVS ISDN System Manual ND 70919 E Issue 1 0 CHAPTER 3 SYSTEM DATA PROGRAMMING ISDN Terminal Data Programming ISDN TERMINAL DATA PROGRAMMING ILC Assignment START DESCRIPTION Assign an ISDN line station number to the CM10 required LEN Assign a Tenant number to each ISDN line CM12 station number Assign a Trunk Restriction Class to each ISDN line station number Assign an ISDN Indial number to the required ISDN line station number Assign a Local Office Code Table number to th
38. card in service NEAX2000 IVS ISDN System Manual Page 50 ND 70919 E Issue 1 0 CHAPTER 2 INSTALLATION Installation Procedure for ISDN BRI BRT Cable Connection via MDF Connect the cable to a NT1 equipment via the MDF as shown in Figure 2 9 Location of AP Slots and LTC Connectors for BRT Figure 2 10 Example of MDF Cross Connection for BRT Figure 2 11 Figure 2 9 BRT Cable Connection via MDF BWB MDF TWISTED PAIR CABLE NT1 LTCO LTC1 LTC2 LTC3 CONNECTOR MAX 1000 m 3280 ft gt NEAX2000 IVS ISDN System Manual ND 70919 E Issue 1 0 Page 51 CHAPTER 2 INSTALLATION Installation Procedure for ISDN BRI Figure 2 10 Location of AP Slots and LTC Connectors for BRT 0 0 L T 0 0 A P 0 0 LTCO LTC1 LOT P01 LOT P02 LOT LOT P04 LOT P05 LOT 0 gt 4 o 07 LTC2 APO06 SLOT
39. cards mounted in PIMO to OFF NOTE 5 Mount the DTI card which receives a source clock signal into PIMO NEAX2000 IVS ISDN System Manual ND 70919 E Issue 1 0 Page 161 CHAPTER 4 CIRCUIT CARD INFORMATION PN 30DTC A DTI PN 30DTC A DTI Locations of Lamps Switches and Connectors SENSE RUN PCM FRM MFRM RMT MRMT AIS BL JPS JPR JP NEAX2000 IVS ISDN System Manual Page 162 ND 70919 E Issue 1 0 CHAPTER 4 CIRCUIT CARD INFORMATION PN 30DTC A DTI Lamp Indications FUNCTION Flashes at 120 IPM when this card is normally operating Remains lit when detecting PCM signal loss Remains lit when detecting Frame Alignment signal loss Remains lit when detecting Multi Frame Alignment signal loss on time slot 16 Remains lit when receiving the alarm from a distant office because Frame Alignment signal loss has been detected at the distant office Remains lit when receiving the alarm from a distant office because Multi Frame Alignment signal loss has been detected at the distant office Remains lit when indicating that the pattern of consecutive 1 is being received The distant office transmits this signal for a loop back test distant B channel status ON More than 10 channel
40. fault cannot be cleared replace the card LED Check the receive line and external equipment Replace the remote DTI card Bit Error Rate exceeds the predetermined value No PCM signals arrive from the distant office Check to see if the DTI cable is correctly connected Plug and unplug the DTI card Repeat this two or three times Check the receive line and external equipment Replace the remote DTI card Frame Alignment signals from the distant office can not be received Check the transmission line and external equipment Replace the DTI card Frame Alignment signals cannot be sent to the remote PBX Remote PBX is in Check the switch settings of the loop back test the remote DTI card o eoc meo aeoo moeooosg NEAX2000 IVS ISDN System Manual ND 70919 E Issue 1 0 Page 191 CHAPTER 5 OPERATION TEST Interoffice Transmission Line Test Table 5 2 Alarm Indications on 30DTI LED LED INDICATION FAULT NORMAL FAULT CAUSE ACTION RUN Flash On or Off Abnormal D Confirm the programming data 120 IPM operation of DTI CMO05 CM07 YY 01 card 2 Check to see if the SENS switch is set as per the AP number 04 15 20 31 assigned by CMO05 3 Reset the MB switch Down Up Down 4 Ifthe fault cannot be cleared replace the card PCM Off On No PCM signals 1 Check to see if the DTI cable is arrive from the correctly connected distant of
41. of Mate Side Trunk for voice channels 2 0 Send when the called party answers e YYY 154 1 00 63 Trunk Route No of Mate Side Trunk for voice channels 2 6 Speech Page 130 NEAX2000 IVS ISDN System Manual ND 70919 E Issue 1 0 CHAPTER 3 SYSTEM DATA PROGRAMMING Event Based CCIS Programming Incoming Termination for Event Based CCIS Calls START DESCRIPTION DATA e YY 00 1 X XXXX DID No 2 000 999 Number Conversion Block No 0 999 CM76 Assign the Number Conversion Block No Convert received digits to Mate Side trunks YYz01 Day Mode e YYz02 Night Mode YYz03 Mode A YYz04 Mode B 1 000 999 Number Conversion Block No assigned by CM76 Y 00 2 BBBBBO000 BBBBB255 Mate Side Trunk No of Virtual Trunk m 2000 IVS ISDN System Manual ND 70919 E Issue 1 0 Page 131 CHAPTER 3 SYSTEM DATA PROGRAMMING Event Based CCIS Programming Access Code Terminating Number Assignment for Outgoing Event Based Calls START DESCRIPTION CM71 Allocate memory to store the terminating numbers to the opposite office Assign terminating numbers of the CM72 opposite office access code for ISDN line ISDN subscriber number to the Memory Slot number allocated by CM71 END DATA 66 XXX YYY XXX 000 299 First Memory Slot No YYY 001 016 Number of Memory Slot allocated Y 0 000 299 Memory Slot No Stored No ZZZ XX Access Code for
42. treated on tandem calls The voice channel of the virtual tie line is released after the call is finished The common signaling channel of virtual tie line is released after all calls on voice channels are finished The release timer is determined by system timer programming for the voice channels and the common signaling channels The ISDN line used for the virtual tie line can also be used as a regular ISDN line The trunk route used for the virtual tie line can be distinguished from the regular ISDN line by assigning different LCR data in system programming NEAX2000 IVS ISDN System Manual Page 20 ND 70919 E Issue 1 0 CHAPTER 1 GENERAL INFORMATION Card Name and Function CARD NAME AND FUNCTION Table 1 2 shows the circuit card names and function for ISDN Table 1 2 ISDN Card Name and Function FUNCTIONAL CARD NAME NAME FUNCTION PN BRTA 1 line Basic Rate 2B D Interface Trunk Card Accommodates one 2 channel POM digital lines PN 2BRTC 2 line Basic Rate 2B D Interface Trunk Card Accommodates two 2 channel PCM digital lines PN 24DTA C Digital Trunk Interface 23B D 1 5 Mbps Card Accommodates 24 channel PCM digital lines PN 30DTC A Digital Trunk Interface 2 Mbps Card Accommodates 30 channel PCM digital lines PN 2ILCA 2 line ISDN Line Circuit Card Provides a physical interface to ISDN Terminals Occupies 8 time slots per one card PN 24PRTA ISDN Primary Rate 23B D Interface Card Pro
43. 000 IVS ISDN System Manual Page 64 ND 70919 E Issue 1 0 CHAPTER 3 SYSTEM DATA PROGRAMMING ISDN PRI Programming ISDN PRI PROGRAMMING Digital Trunk Data Assignment START DESCRIPTION Assign an AP number to the DTI PRT card The AP number must match the SENSE switch setting on the DTI PRT card Specify the AP highway channel for 24DTI PRT card Assign trunk numbers to each channel number on the DTI PRT card The system allocates time slots to consecutive channels from lowest to highest channel number assigned To minimize the number of time slots allocated assign trunk numbers to the consecutive channels on each card Never skip channels in CMO7 Allow second Dial Tone when dialing access code assigned by CM20 for ISDN B channel route DATA Y 0 04 15 20 31 AP No 09 DTI card 12 PRT card Y 1 04 15 20 31 AP No 0 Expanded Highway channel 128 time slots 1 lt q Basic Highway channel 128 time slots YY 01 XX ZZ XX 04 15 20 31 AP No assigned by CM05 ZZ 00 23 Channel No of 24DTI PRT 01 15 17 31 Channel No of 30DTI D000 D255 Trunk No Any trunk No already assigned by CM10 cannot be used Y 2 04 0 ForISDN trunk route 219 Dial Tone is provided 14 No 2 Dial Tone NEAX2000 IVS ISDN System Manual ND 70919 E Issue 1 0 Page 65 CHAPTER 3 SYSTEM DATA PROGRAMMING ISDN PRI Programming DESCRIPTION Assign the necessary functions to the
44. 05 CNS Release Signal from distant office 1 00 63 B channel D channel Trunk Route No 2 1 lt q Release signal arrives NOTE 2 e YYz09 Incoming Connection Signaling 1 00 63 B channel Trunk Route No 2 08 ISDN 1 00 63 D channel Trunk Route No 2 15 lt q Not used e YY 11 Toll Restriction 1 00 63 B channel Trunk Route No 2 0 Provided NOTE 1 3 lt q Not provided e YY 12 Number of digits to be received on DID 1 00 63 B channel Trunk Route No 2 0 1 digit 1 2 digits 2 3 digits 3 lt q 4 digits NOTE If CM35 YYY 143 is set to 1 for Event Based CCIS the number of digits received on DID must be assigned e YY 14 SMDR for outgoing call 1 00 63 B channel Trunk Route No 2 0 Not provided 1 lt q Provided NOTE 1 e YYz15 Kind of Call Termination Indica tor Key Lamp on ATT 1 00 63 B channel Trunk Route No 2 00 07 C O Incoming 0 7 NOTE 1 NEAX2000 IVS ISDN System Manual Page 68 ND 70919 E Issue 1 0 CHAPTER 3 SYSTEM DATA PROGRAMMING ISDN PRI Programming 2 DESCRIPTION DATA CM35 NOTE 1 This data should be assigned to e YY 16 the B channel trunk route For Hooking Signal Sending to outside D channel trunk route no data 1 00 63 B channel Trunk Route No setting is required 2 0 Not sending NOTE 1 NOTE 2 This data should be assigned to e YY 18 Digit conversion on DID call both B channel trunk route and 1 00 63 B channel Trunk Route No D chann
45. 1 1 Data Data NEAX2000 IVS ISDN System Manual Page 176 ND 70919 E Issue 1 0 CHAPTER 4 CIRCUIT CARD INFORMATION PN SCO1 DCH PN SCO1 Locations of Lamps Switches and Connectors SENSE RUN MB SWO LC LPB Lamp Indications FUNCTION Flashes at 120 IPM while this card is operating normally Remains lit when communications are normally ongoing with the D channel data links connected Not used NEAX2000 IVS ISDN System Manual ND 70919 E Issue 1 0 Page 177 CHAPTER 4 CIRCUIT CARD INFORMATION PN SCO1 DCH Switch Settings SWITCH NAME SENS Rotary SW SWITCH NUMBER SWO 4 ON SETTING POSITION FUNCION Set the switch to match the AP Number 04 31 to be set by 5 AP No 0 4 OFF SW No MB Toggle SW ST NOTE 2 For make busy For normal operation SWO Piano Key SW OFF Always set to OFF Always set to OFF Always set to OFF AP No 04 15 AP No 20 31 Continued Page 178 NEAX2000 IVS ISDN System Manual ND 70919 E Issue 1 0 CHAPTER 4 CIRCUIT CARD INFORMATION PN SCO1 DCH SWITCH SWITCH SETTING NAME NUMBER POSITION FESTIS SW1 DIP SW Always set to OFF ON pi 3 300 Always set to OFF Always set to OFF Always set to OFF
46. 1 lt q Not provided NEAX2000 IVS ISDN System Manual ND 70919 E Issue 1 0 Page 77 CHAPTER 3 SYSTEM DATA PROGRAMMING ISDN BRI Programming DESCRIPTION NOTE 1 This data should be assigned to the B channel trunk route For D channel trunk route no data setting is required NOTE 2 This data should be assigned to both B channel trunk route and D channel trunk route Specify the method of Layer 1 activation Assign ISDN Local Office Code Assign Service Profile ID SPID to each B channel number North America Only 1 2 DATA 19 00 63 B channel Trunk Route No 0 3 Programmable PAD See CM42 4 7 Fixed PAD NOTE 1 NOTE For details of PAD data refer to Command Manual YY 28 Outgoing Trunk Queuing 00 63 B channel Trunk Route No 0 Restricted NOTE 1 YY 39 Trunk release by detection of reversal of tip and ring 00 63 B channel Trunk Route No 1 lt q To release NOTE 1 YY 90 Assignment of BRT route for ISDN 00 63 B channel D channel Trunk Route No 2 ISDN Basic Rate Interface NOTE 2 YYY 144 00 63 B channel D channel Trunk Route No 0 Activated by call event 1 lt q Always activated YY 05 00 14 Local Office Table No assigned by CM30 YY 34 12 digits YY 30 XX Z XX 04 15 AP No assigned by CM05 Z 0 3 BchNo XXXX ZZZZ XXXX ISDN Subscriber No ZZZZ SPID Page 78 NEAX2000 IVS ISDN System Manual ND 70919 E Issue 1
47. 255 LCR TR Pattern No 000 255 159 Type of Network ID 00 07 Type of Network ID No No data Page 94 NEAX2000 IVS ISDN System Manual ND 70919 E Issue 1 0 CHAPTER 3 SYSTEM DATA PROGRAMMING ISDN Feature Programming DESCRIPTION CM8A Assign the Network ID Plan number Assign the Network ID character Specify whether Call By Call is Feature or Service Assign the Binary Facility Coding Value 1 2 1 2 1 2 DATA YYYY 5000 5255 LCR TR Pattern No 000 255 160 Network ID Plan 00 15 Network ID Plan No lt No data YYYY 5000 5255 LCR TR Pattern No 000 255 161 Network ID Character X XXX X 0 9 A B YYYY 5000 5255 LCR TR Pattern No 000 255 162 Feature Service O0 Feature 1 lt q Service YYYY 5000 5255 LCR TR Pattern No 000 255 163 Binary Facility Coding Value For AT amp T 01 SDN 02 MEGACOM800 03 MEGACOM 04 Not used 05 Not used 06 ACCUNET 07 Not used 08 INTERNATIONAL800 16 AT amp T MULTIQUEST No data For Northern Telecom 01 Private 02 INWATS 03 OUTWATS 04 Foreign Exchange FX 05 Tie Trunk TIE No data NEAX2000 IVS ISDN System Manual ND 70919 E Issue 1 0 Page 95 CHAPTER 3 SYSTEM DATA PROGRAMMING ISDN Feature Programming DESCRIPTION DATA CMB8A Assign the WATS Band number e YYYY 5000 5255 LCR TR Pattern No 000 255 1 164
48. 59 1 197 1 160 1 198 1 161 1 199 1 162 1 200 1 163 1 164 1 165 1 166 1 167 1 168 1 169 1 170 1 171 1 172 1 173 1 174 1 175 1 176 1 177 1 178 1 179 1 180 1 181 1 182 1 183 1 184 1 ISSUE 1 ISSUE 2 ISSUE 3 ISSUE 4 DATE FEBRUARY 2000 DATE DATE DATE ISSUE 5 ISSUE 6 ISSUE 7 ISSUE 8 DATE DATE DATE DATE 2000 IVS ISDN System Manual Revision Sheet 3 3 ND 70919 E NEAX2000 IVS ISDN System Manual TABLE OF CONTENTS Page LIST TIPO i d Nanda had ia RC Gn ee iv M INT TABIE R RE V iiie C erpe 1 54 9 Ropa Per sees eoa d Gao 1 OUTLINE GE THES MANUAL dob 1 REFERENCE MANUALS 24213 2 CHAPTER 1 GENERAL INFORMATION 9605050 CRI a B o ce 3 ird 190015 c rere 4 System Outline of ISDN PRI a ac cd dob EROR ARCA Roa n ER RR Rl 4 System Outline of ISDN BRI cco weeds cies 5 System Outline PASEO AE A RA ERA ade a ess 6 System Outline of ISDN Terminal 2 icons Re Erb Ee Rd 8 10 10 RUM 10 11 C RR 12 Pie LT P 13 E EU R
49. B5 19 m 20 1 21 m 22 CB6 23 m 24 1 The S bit is the first bit in each frame Frames are repeated in the order shown above Frames 6 12 and 24 become signal frames in the 4 Kbps Data Link column means that the frame is usually assigned to 1 Page 32 NEAX2000 IVS ISDN System Manual ND 70919 E Issue 1 0 CHAPTER 1 GENERAL INFORMATION DTI Specifications Frame Configuration of 30DTI Based on 30 channel transmission method of ITU T Specification the frame configuration consists of 16 multi frame each frame having 32 time slots Figure 1 15 shows the frame configuration and Table 1 8 shows the details of time slot assignment Figure 1 15 Frame Configuration of 30DTI FRAME 0 FRAME 1 FRAME 2 FRAME 3 Re FRAME 14 FRAME 15 125 sec NEAX2000 IVS ISDN System Manual ND 70919 E Issue 1 0 Page 33 CHAPTER 1 GENERAL INFORMATION DTI Specifications Table 1 8 Time Slot Assignment of 30DTI TIME SLOT No EVEN No FRAME ODD No FRAME Frame Alignment Signal FAS bo 141 2 3 4 X 0 0 1 1 FAS 122 REMOTE ALARM CRC BIT CRC BIT 0 NORMAL 1 FRAME LOSS Voice Channel B channel CH1 CH15 D Channel Signaling Voice Channel B channel CH17 CH31 NEAX2000 IVS ISDN System Manual Page 34 ND 70919 E Issue 1 0 CHAPTER 2 INSTALLATION This chapter explains the hardware installation p
50. BRT card DTI INITIAL Assign ISDN trunk number to each Channel number of BRT NOTE Be sure to assign the trunk numbers to all circuits 00 03 of the 2BRTC card even if only one PCM digital line is accommodated to the card Set make busy to the unused trunk numbers by CME5 Y 1 2nd data 0 Assign trunk route to each ISDN trunk used for Voice channel B channel NOTE BRT route must be separated from analog trunk routes 1 2 DATA Y 0 04 15 20 31 AP No 10 BRT card YY 06 04 15 20 31 AP No of BRT assigned by CM05 ISDN Protocol Type 17 Australia 18 New Zealand 20 AT amp T 4 5 ESS 21 NTI DMS 100 250 22 Australia ETSI 24 ETSI Standard Brazil Columbia Indonesia 25 ITU T Standard Thailand 27 USA NI 28 USA NI 2 63 lt q Not used YY 02 XX ZZ XX AP No assigned by CM05 ZZ Channel No 00 01 BRTA 00 03 2BRTC D000 D255 Trunk No Trunk No already assigned by CM10 cannot be used YY 00 000 255 Trunk No assigned by CMO7 YY 01 00 63 Trunk Route Page 118 NEAX2000 IVS ISDN System Manual ND 70919 E Issue 1 0 CHAPTER 3 SYSTEM DATA PROGRAMMING Event Based CCIS Programming DESCRIPTION Assign the trunk route data to each ISDN incoming trunk used for Voice channel only Assign an ISDN subscriber number last 4 digits of telephone number to each ISDN trunk Assign ISDN Local Office Code Table number to each ISDN trunk Assign IS
51. DN Local Office Code Assign the last 4 digits of telephone number Service Profile ID SPID to each B channel number North America Only Assign trunk route data to the route number assigned by CM30 YY 00 DATA YY 02 Day Mode YY 03 Night Mode YY 40 Mode A YY 41 Mode B 000 255 Trunk No assigned by CMO7 Y 01 18 ISDN Indial YY 19 000 255 Trunk No assigned by CMO7 Y 01 XXXX ISDN Subscriber No YY 34 000 255 Trunk No assigned by CMO7 Y 01 00 14 Local Office Code Table No YY 05 00 14 Local Office Table No assigned by CM30 Y 34 12 digits YY 30 XX Z XX 04 15 AP No assigned by CM05 Z 0 3 Bch No XXXX ZZZZ Last 4 digits of tel No SPID 8 digits YY 00 Kind ofTrunk Route 00 63 B channel Trunk Route No 00 ISDN Trunk 00 63 D channel Trunk Route No 15 lt q Not used YY 04 Answer signal from distant office 00 63 B channel Trunk Route No 2 Answer signal arrives ISDN Trunk 00 63 D channel Trunk Route No 74 amp Not used NEAX2000 IVS ISDN System Manual ND 70919 E Issue 1 0 Page 119 CHAPTER 3 SYSTEM DATA PROGRAMMING Event Based CCIS Programming DESCRIPTION Specify the number of digits to be received on DID NOTE 1 This data should be assigned to the B channel trunk route For D channel trunk route no data setting is required Determine trunk seizure sequence NOTE 2 This data should be assigned to both B ch
52. DN Terminal interface to the system in addition to the required equipment for ISDN PRI or ISDN BRI Table 2 3 ISDN Terminal Required Equipment EQUIPMENT DESCRIPTION QUANTITY REMARKS PN SCOS3 ISDN Channel Handler Card 4 LC card ICH PN 21LCA ISDN Line Circuit Card 2 terminal card ILC Event Based CCIS Required Equipment Table 2 4 shows the required equipment to provide Event Based CCIS to the system in addition to the required equipment for ISDN PRI or ISDN BRI Table 2 4 Event Based CCIS Required Equipment EQUIPMENT DESCRIPTION QUANTITY REMARKS PN SCOO Common Channel Handler 1 8 1 CCH Card NEAX2000 IVS ISDN System Manual Page 40 ND 70919 E Issue 1 0 CHAPTER 2 INSTALLATION Installation Procedure for ISDN PRI INSTALLATION PROCEDURE FOR ISDN PRI Install the equipment for ISDN PRI according to the procedure shown in Figure 2 2 NOTE For Call Recording of ISDN call install the equipment for SMDR or CIS For details refer to the Installation Procedure Manual Figure 2 2 Installation Procedure for ISDN PRI See Page 42 Mounting DTI and DCH Card PRT Card Mounting CONN Card See Page43 NOTE Selection of PLO in See CHAPTER 4 MP Card See Page 44 DTI PRT Cable Connection via MDF Cable Connection via CONN Card See Page 47 NOTE NOTE This procedure is required when using CONN card to connect a coaxial cable for DTI NEAX2000 IVS ISDN
53. EAX2000 IVS ISDN System Manual Page 180 ND 70919 E Issue 1 0 CHAPTER 4 CIRCUIT CARD INFORMATION PN SCO3 ICH Switch Settings SWITCH NAME SENSE Rotary SW GS NOTE 1 SWITCH NUMBER No 04 05 06 07 08 09 10 11 12 13 14 15 SETTING POSITION FUNCION Set the switch to match the AP Number 04 15 to be set by 5 SW No 45678 0 3 Not used MB Toggle SW AS UP For make busy DOWN For normal operation The figure in the SWITCH NAME column and the position inthe SETTING POSITION column indicate the standard setting of the switch When the switch is not set as shown by the figure and _ the setting of the switch varies with the system concerned NOTE 1 Set the groove on the switch to the desired position NOTE 2 When the power is on flip the MB switch to ON UP position before plugging unplugging the circuit card NEAX2000 IVS ISDN System Manual ND 70919 E Issue 1 0 Page 181 CHAPTER 4 CIRCUIT CARD INFORMATION PZ M542 CONN PZ M542 CONN Locations of Lamps Switches and Connectors RCV21 1 FOR TO CHAMP CONNECTOR MDF MO iil CIRCUIT L COAXIAL CONNECTOR Lamp Indications This card has no lamps TO LTC CONNECTOR ON BWB IN PIM Page 182 NEAX2000 IVS ISDN System Manual ND 70919 E Issue 1 0 CHAPTER 4 CIRCUIT CARD INFORMATION PZ M542 C
54. EP 7 STEP 8 STEP 9 On the DTIO 1 PRTO 1 BRTO 1 cards set the switches as shown in STEP 1 to input clock signals from the clock supply Route 1 Repeat STEP 2 and STEP 3 of this procedure On the DTI PRT BRT cards set the switches as follows to change the clock supply route from 1 to 0 30DTIO card SW 1 to ON SW 2 to OFF card SW 1 to OFF SW 2 to ON PRTO 24DTIO card SWO 1 to ON SWO0 2 to OFF PRT1 24DTI card SWO 1 to OFF SWO 2 to ON BRTO card SWO 2 to ON SWO0 3 to ON e BRT1 card SWO 2 to ON SWO0 3 to OFF 2BRTO card SW11 2 to ON SWO0 3 to ON 2BRT1 card SW11 2 to ON SWO0 3 to OFF The CLK lamp on the MP card lights Repeat STEP 2 and STEP 3 of this procedure NOTE f noise periodically occurs replace the MP card after checking the switch settings on the MP card and do the above test again Interoffice Synchronization Test This test checks to see if noise occurs while calling with the opposite office by difference of the clock signal frequency between the offices Do the following procedure using In Service trans mission lines STEP 1 STEP 2 STEP 3 Originate an outgoing call via trunks Check the speech quality if noise distortion or click occurs during a few minutes with the opposite office mutually On the DTMF telephone set keep pressing any dial button and check to see if noise periodically occurs on the DTMF signals coming from the calling station in the op
55. GTH 0 40 m 0 131 2 ft 40 80 m 131 2 262 5 ft 80 120 m 262 5 394 ft 120 160 m 394 525 ft 160 200 m 525 656 ft Signal is not sent Continued NEAX2000 IVS ISDN System Manual Page 170 ND 70919 E Issue 1 0 CHAPTER 4 CIRCUIT CARD INFORMATION PN 24PRTA PRT SWITCH SETTING SWITCH NAME NUMBER POSITION FUNCTION aW OFF Not used Piano Key SW OFF Not used OFF Not used E ON AP No 04 15 ON NOTE 4 OFF AP No 20 31 5 2 DIP SW OFF Always set to OFF OFF TETT North America only for AT amp T Deletion of Area Code on International Outgoing call ON No deletion of Area Code on FF 9 International Outgoing call Australia Other countries OFF Always set to OFF OFF Always set to OFF OFF Always set to OFF OFF Always set to OFF OFF Always set to OFF OFF Always set to OFF Always set to OFF Continued NEAX2000 IVS ISDN System Manual ND 70919 E Issue 1 0 Page 171 CHAPTER 4 CIRCUIT CARD INFORMATION PN 24PRTA PRT SWITCH NAME JPRO Jumper Pin SWITCH NUMBER SETTING POSITION FUNCTION Neutral grounding on the receiving line is provided Neutral grounding on the receiving line is not provided JPR1 Ju
56. H NAME NUMBER SW1 Push SW Bis 4 SETTING POSITION FUNCTION For initializing CPU SW2 Piano Key SW ON A law Australia OFF law North America 8 Selection of PLOO input Phase Locked Oscillator For clock receiver office FUNCTION 1 5 MHz clock For PN 24DTA C PN 24PRTA 192 kHz clock For PN BRTA 2 MHz clock For PN 30DTC A PN 2BRTC For clock source office Not used SW2 2 SW2 3 OFF OFF ON When using RS1 port for built in MODEM When using RS1 port for RS 232C Continued NEAX2000 IVS ISDN System Manual Page 143 ND 70919 E Issue 1 0 CHAPTER 4 CIRCUIT CARD INFORMATION PN CP14 MP SWITCH NAME SW4 DIP SW SWITCH NUMBER SETTING POSITION Not used Not used Selection of PLO1 input Phase Locked Oscillator For clock receiver office FUNCTION 1 5 MHz clock For PN 24DTA C PN 24PRTA 192 kHz clock For PN BRTA 2 MHz clock For PN 30DTC A PN 2BRTC Not used For clock source office SW4 3 SW4 4 OFF OFF VR Rotary SW 20 0 Variable Resistor for External Hold Tone Source 0 20 Kohms Clockwise DK Connector LB 01 Ground detection Ground sending Continued Page 144 NEAX2000 IVS ISDN System Manual ND 70919 E Issue 1 0 CHAPTER 4 CIRCUIT CARD INFORMATION PN CP14 MP SWITCH SET
57. H card PN SCO0 The AP number must match the SENSE switch setting on the CCH card Assign a CCH channel number to each CCH card Assign the trunk number used as the common signaling channel Assign an Originating Point Code OPC of own office and Destination Point Code DPC of opposite office to each CCH channel NOTE The OPC is used to designate an originating office in the No 7 CCIS network A single OPC of own office should be assigned to all CCH channels provided in the same system Assign ACM signal waiting timer Assign CCH channel to which a signaling message is transferred according to the Destination Point Code DPC received END DATA Y 0 04 15 20 31 AP No 11 CCH Card YY 07 0 7 CCH channel No 04 15 20 31 AP No of CCH Card YY 00 0 7 CCH channel No 000 255 Trunk No assigned by CM07 YY 01 0 7 CCH channel No 00001 16367 OPC YY 02 0 7 CCH channel No 00001 16367 DPC YY 10 0 7 CCH channel No 14 28 sec 00001 16367 DPC 0 7 CCH channel No Page 134 NEAX2000 IVS ISDN System Manual ND 70919 E Issue 1 0 CHAPTER 3 SYSTEM DATA PROGRAMMING Event Based CCIS Programming Tandem Connection Programming When providing Tandem Connection ISDN to CCIS CCIS to ISDN do the following programming START DESCRIPTION DATA Specify the combination of trunk routes Y 0 CM36 allowing the tandem connection 1 XX ZZ XX 00 63 Incoming Trunk Route ZZ
58. I PRT card the system recognizes the lowest and highest channel numbers to which trunk numbers have been assigned and allocates time slots to all the channels within them If trunk numbers are assigned to discontinuous channels in this case the system also allocates time slots to channels not assigned For example in Figure 1 11 even when Channel 1 through Channel 10 have been assigned by the system data programming CMO7 YY 01 except Channel 5 the system allocates a total of 10 time slots for all 10 channels Therefore to avoid allocation of unnecessary time slots it is recommended that consecutive channels are assigned on each DTI PRT card In the case of the DCH card one time slot is allocated for setting up a fixed path between the DTI and the DCH by assigning Channel 16 of the DTI as the D Channel Figure 1 11 Time Slot Allocation for DTI HIGHEST CHANNEL 10 TIME SLOTS ARE ALLOCATED EVEN WHEN 5 1 NOT ASSIGNED LOWEST CHANNEL NEAX2000 IVS ISDN System Manual ND 70919 E Issue 1 0 Page 25 CHAPTER 1 GENERAL INFORMATION System Conditions Line Distance Between PBX and NT1 ISDN Terminal Figure 1 12 shows the line distance between PBX and NT1 and the line distance between PBX and ISDN Terminal Figure 1 12 Line Distance Between PBX and NT1 ISDN Terminal Max 600 m Max 1000 m I 1965ft 3280 ft MDF PBX A NT1 TO ISDN lt 1 B
59. ICE TRANSMISSION LINE TEST To confirm inter office synchronization and speech quality using In Service transmission lines do the following procedure STEP 1 STEP 2 STEP 3 STEP 4 STEP 5 STEP 6 Connect the transmission line to the MDF or CONN Make busy the channels except the channel tested by CME5 Confirm indication lamps on the DTI PRT BRT card as per the following table e Alarm Indications on 24DTI Table 5 1 e Alarm Indications on 30DTI Table 5 2 Alarm Indications on 24PRT Table 5 3 Alarm Indications on BRT Table 5 4 Originate an outgoing call via trunk After an outgoing connection via trunks has been established confirm inter office synchronization as follows the DTMF telephone set keep pressing any dial button Check to see if there are noise or abnormal tones Do the above test again in the opposite direction Repeat the test for all channels When completed make idle all channels by CME5 Page 190 NEAX2000 IVS ISDN System Manual ND 70919 E Issue 1 0 CHAPTER 5 OPERATION TEST Interoffice Transmission Line Test Table 5 1 Alarm Indications on 24DTI LED INDICATION FAULT NORMAL FAULT CAUSE ACTION Flash On or Off Abnormal Confirm the programming data 120 IPM operation of DTI CMO05 CM07 YY 01 card Check to see if the SENS switch is set as per the AP number 04 15 20 31 assigned by CMO05 Reset the MB switch Down Up Down If the
60. ISDN ZZZ ISDN Subscriber No of Oppo site Office Max 26 digits Page 132 NEAX2000 IVS ISDN System Manual ND 70919 E Issue 1 0 CHAPTER 3 SYSTEM DATA PROGRAMMING Event Based CCIS Programming Release Timer for Virtual Tie Lines Home Side and Mate SideTrunks START DESCRIPTION Specify the release timer for voice channels of virtual tie line If there are no calls for predetermined time the voice channels used for Event Based CCIS is released Specify the release timer for CCH channel of virtual tie line If all the voice channels are released and there are no calls for predetermined time the CCH channel used for Event Based CCIS is released DATA e Y 0 1 87 Virtual Tie Line Release Timer for Voice Channels 2 02 2 4 4 8 sec 2 4 sec increments i 2 30 69 6 72 0 sec 32 24 sec 24 sec increments 2 2 70 936 sec 72 1 min 1 min increments 2 2 99 28 min 3 min Error span 2 4 sec Y 0 89 Virtual Tie Line Release Timer for Common Signaling Channel 02 2 4 4 8 sec 2 4 sec increments 2 2 30 69 6 72 0 sec 32 24 sec 24 sec increments 2 2 70 936 sec 72 1 min 1 min increments 2 2 99 28 min min Error span 2 4 sec NEAX2000 IVS ISDN System Manual ND 70919 E Issue 1 0 Page 133 CHAPTER 3 SYSTEM DATA PROGRAMMING Event Based CCIS Programming CCH Data Assignment START DESCRIPTION Assign an AP number to the CC
61. ISDN primary rate D channel data link connec tion failure Check the status of the local office side line or the public network side line Bit Error Rate exceeds the pre determined value Check the receive line and external equipment Replace the remote PRT card No PCM signals arrive from the distant office Check to see if the PRT cable is correctly connected Plug and unplug the PRT card Repeat this two or three times Frame Alignment signals from the distant office can not be received Check the receive line and external equipment Replace the remote PRT card Frame Alignment signals cannot be sent to the remote PBX Check the transmission line and external equipment Replace the PRT card Remote PBX is in the loop back test Check the switch settings of the remote PRT card NEAX2000 IVS ISDN System Manual ND 70919 E Issue 1 0 Page 193 CHAPTER 5 OPERATION TEST Interoffice Transmission Line Test Table 5 4 Alarm Indications on BRT LED INDICATION FAULT NORMAL FAULT CAUSE ACTION LED Flash On or Off Abnormal Confirm the programming data 120 IPM operation of BRT CMO05 CM07 YY 02 card Check to see if the SENS switch is set as per the AP number 04 15 assigned by CMO5 Reset the MB switch Down Up Down If the fault cannot be cleared replace the card Transmission line Confirm circuit line st
62. M DATA PROGRAMMING Event Based CCIS Programming To provide Verification of Connection for Event Based CCIS do the following programming The following data must be set on the opposite PBX identically See also the data setting example on the following pages NOTE 1 This feature is available only for the connection between the NEAX2000 IVS 7400ICS M100MX s The same programming must be set on the opposite office NOTE 2 This feature is available for installations consisting of PRI to PRI or PRI to BRI Do not use for BRI to BRI START DESCRIPTION DATA Provide Verification of Connection to the YYY 152 Mate Side trunk route for the voice 1 00 63 Trunk Route No of Mate Side channels and the common signaling Trunk for voice channels and channel common signaling channel 2 0 To provide Assign the ISDN subscriber number of YY 06 own office for the voice channel route and 1 000 255 Trunk No of Mate Side Trunk the common signaling channel route for voice channels and This number is sent and verified with the common signaling channel number which is set by CM72 on the 2 X XXX Subscriber No of ISDN line opposite office for voice channels and common signaling channel Max 16 digits Assign the abbreviated codes for YY 40 terminating number of the opposite office 1 00 63 Trunk Route No of Mate Side The terminating number and its memory Trunk for voice channels and allocation should be assigned by CM71 c
63. MMING ISDN Terminal Data Programming 4 Station to Station Calling When an ISDN Terminal user dials an ISDN line station number within the system the system connects the call with all ISDNTerminals PBX ISDN Line Station No 300 IL 4 ISDN Terminal ISDN Terminal Station No 407 Station No 400 ISDN Line Station i 301 21 21 ISDN Terminal ISDN Terminal Station No 417 Station No 410 Do the programming of Point to Multipoint Connection See Page 105 NEAX2000 IVS ISDN System Manual Page 114 ND 70919 E Issue 1 0 CHAPTER 3 SYSTEM DATA PROGRAMMING Event Based CCIS Programming EVENT BASED CCIS PROGRAMMING Programming Summary Do the system data programming for Event Based CCIS according to the procedure shown in Figure 3 2 As for the CCIS feature programming refer to the CCIS System Manual Figure 3 1 shows an outline of BRI to BRI connections Figure 3 1 Outline of BRI to BRI Connections BRI TRUNKS BRI TRUNKS MATE SIDE TRUNKS MATE SIDE TRUNKS V HOME SIDE TRUNKS HOME SIDE TRUNKS T l C CCH CCH PBX A PBX B Programming for PBX A and PBX B is required on each programming procedure NEAX2000 IVS ISDN System Manual ND 70919 E Issue 1 0 Page 115 CHAPTER 3 SYSTEM DATA PROGRAMMING Event Ba
64. NEAX2000 IVS ISDN System Manual ND 70919 E Issue 1 0 Page 43 CHAPTER 2 INSTALLATION Installation Procedure for ISDN PRI DTI PRT Cable Connection via MDF When you use a twisted pair cable connect the cable to a NT1 equipment via the MDF as shown in Figure 2 3 Location of AP Slots and LTC Connectors for DTI PRT Figure 2 4 Example of MDF Cross Connection for DTI PRT Figure 2 5 Figure 2 3 DTI PRT Cable Connection via MDF MDF TWISTED PAIR CABLE SHIELD TYPE LTCO LTC1 LTC2 LTC3 CONNECTOR 4 200 m 655 ft 24 DTI gt MAX 400 m 1310 ft 30 DTI NEAX2000 IVS ISDN System Manual Page 44 ND 70919 E Issue 1 0 CHAPTER 2 INSTALLATION Installation Procedure for ISDN PRI Figure 2 4 Location of AP Slots and LTC Connectors for DTI PRT 0 0 L T 0 0 A P 0 0 LTCO LTC1 LOT P01 LOT P02 LOT LOT P04 LOT P05 LOT 0 4 gt 4 o 07 LTC2
65. NEC ND 70919 E ISSUE 1 STOCK 151988 2 NEAX 2000 IVS INTEGRATED VOICE SERVER ISDN System Manual FEBRUARY 2000 NEC America Inc LIABILITY DISCLAIMER NEC America Inc reserves the right to change the specifications functions or features at any time without notice NEC America Inc has prepared this document for use by its employees and customers The information contained herein is the property of NEC America Inc and shall not be reproduced without prior written approval from NEC America Inc NEAX and are registered trademarks of NEC Corporation MATWorX is a trademark of NEC Corporation Copyright 2000 NEC America Inc Printed in U S A ISSUE No ISSUE No PAGE No PAGE No 1 2 3 4 5 6 7 1 4 5 6 7 8 i 1 33 1 i 1 34 1 ii 1 35 1 iv 1 36 1 v 1 37 1 vi 1 38 1 1 1 39 1 2 1 40 1 3 1 41 1 4 1 42 1 5 1 43 1 6 1 44 1 7 1 45 1 8 1 46 1 9 1 47 1 10 1 48 1 11 1 49 1 12 1 50 1 13 1 51 1 14 1 52 1 15 1 53 1 16 1 54 1 17 1 55 1 18 1 56 1 19 1 57 1 20 1 58 1 21 1 59 1 22 1 60 1 23 1 61 1 24 1 62 1 25 1 63 1 26 1 64 1 27 1 65 1 28 1 66 1 29 1 67 1 30 1 68 1 31 1 69 1 32 1 70 1 ISSUE 1 ISSUE 2 ISSUE 3 ISSUE 4 DATE FEBRUARY 2000 DATE DATE DATE ISSUE 5 ISSUE 6 ISSUE 7 ISSUE 8 DATE DATE DATE DATE NEAX2000
66. NECTOR LTC1 J LTC1 P RECEIVE TO NT1 2 COAXIAL CONNECTOR Page 48 NEAX2000 IVS ISDN System Manual ND 70919 E Issue 1 0 CHAPTER 2 INSTALLATION Installation Procedure for ISDN BRI INSTALLATION PROCEDURE FOR ISDN BRI Install the equipment for ISDN BRI according to the procedure shown in Figure 2 8 NOTE For Call Recording of ISDN call install the equipment for SMDR or CIS For details refer to the Installation Procedure Manual Figure 2 8 Installation Procedure for ISDN BRI See Page 50 Mounting BRT Card Selection of PLO in MP Card BRT Cable Connection via MDF See CHAPTER 4 See Page 51 NEAX2000 IVS ISDN System Manual ND 70919 E Issue 1 0 Page 49 CHAPTER 2 INSTALLATION Installation Procedure for ISDN BRI Mounting BRT Card 1 2 Before mounting the BRT PN BRTA 2BRTO card set the MB switch to UP position and set the other switches to appropriate position See CHAPTER 4 ATTENTION Contents Static Sensitive Mount the BRT card in the following AP slots on PIMO PIM7 _ _ _ PIMO 7 APOO AP1 1 The AP11 slot on PIMO is available only when the FP card is not mounted in the FP11 slot on PIMO NOTE The BRT BRTO BRT1 which sends a clock signal to PLO of the MP card must 3 be mounted in the AP slots on PIMO After mounting the card set the MB switch to DOWN position to put the
67. NT1 TO ISDN No No 84 Max 50 m 164 ft i Max 200 m Max 400 m 655 ft 1310 ft ISDN Terminal NT1 Network Termination One C ul A Point to Point Connection No 1 No 8 B Pointto Multipoints Connection lt 1 21 Extended Passive Bus C Point to Multipoints Connection Short Max 150m Distance Passive Bus 491 ft NOTE 1 The line distance marked by shows the value when the 0 5 twisted pair cable is used NOTE 2 The line distance marked by shows the value when the 0 656 twisted pair cable is used NEAX2000 IVS ISDN System Manual Page 26 ND 70919 E Issue 1 0 CHAPTER 1 GENERAL INFORMATION DTI Specifications DTI SPECIFICATIONS Transmission Characteristics Table 1 5 Transmission Characteristics CHARACTERISTICS 1 Output Line Rate Line Code Line Impedance Pulse Amplitude Base to Peak Pulse Width 24 CHANNEL 1 544 Mbps 50 ppm AMI with ZCS B8ZS 100 ohms 3 volts 0 6 volts 324 ns 30 ns AMI Alternate Mark Inversion 265 Zero Code Suppression B8ZS Bipolar Eight Zero Substitution 30 CHANNEL 2 048 Mbps 50 ppm HDB3 High Density Bipolar 75 ohms Coaxial Cable 120 ohms Twisted Pair Cable 2 37 volts nominal Coaxial Cable 3 volts nominal Twisted Pair Cable 244 ns nominal NEAX2000 IVS ISDN System Manual ND 70919 E Issue 1 0 Page 27 CHAPTER 1 GENERAL INFORMATION DTI
68. O input When one DTI is provided MP card will receive the clock signal from DTIO at its PLOO input under normal condi tions If a clock failure occurs with DTIO MP card automatically switches to the PLO1 input which gets from DTI When more than one DTI is provided NOTE 4 When the PBX is a clock source office set the SW 1 and SW 2 on all the DTI cards mounted in PIMO to OFF NOTE 5 Mount the DTI card which receives a source clock signal into PIMO NEAX2000 IVS ISDN System Manual ND 70919 E Issue 1 0 Page 167 CHAPTER 4 CIRCUIT CARD INFORMATION PN 24PRTA PRT PN 24PRTA PRT Locations of Lamps Switches and Connectors SENSE RUN MB 1005 SW 5 0 LC LPB CRC PCM FRM RMT AIS BL co co c co co co co c NEAX2000 IVS ISDN System Manual Page 168 ND 70919 E Issue 1 0 CHAPTER 4 CIRCUIT CARD INFORMATION PN 24PRTA PRT Lamp Indications FUNCTION Flashes at 120 IPM while this card is operating normally Remains lit when communications are normally ongoing with the D channel data links connected Not used Remains lit when detecting Cyclic Redundancy Checking CRC errors Remains lit when detecting PCM signal loss Remains lit when detecting Frame Alignment signal loss Remains lit when receiving Frame Alignment signal loss alarm from a distant office Remains lit when a pattern of consecutive 1
69. ONN Switch Settings SWITCH SETTING SWITCH NAME NUMBER POSITION FUNCTION For coaxial connectors No 0 circuit For champ connector LT connector No 0 circuit For coaxial connectors No 1 circuit For champ connector LT connector No 1 circuit For coaxial connectors No 2 circuit For champ connector LT connector No 2 circuit The figure the SWITCH NAME column and the position in C in the SETTING POSITION column indicate the standard setting of the switch When the switch is not set as shown by the figure and C 5 the setting of the switch varies with the system concerned NEAX2000 IVS ISDN System Manual ND 70919 E Issue 1 0 Page 183 CHAPTER 4 CIRCUIT CARD INFORMATION PZ M557 CONN PZ M557 CONN Locations of Lamps Switches and Connectors No 2 CIRCUIT L RCV10 1 FOR TO CHAMP No 1 CONNECTOR MDF 1 CIRCUIT L 4 r COAXIAL CONNECTOR Lamp Indications This card has no lamps TO LTC CONNECTOR ON BWB IN PIM Page 184 NEAX2000 IVS ISDN System Manual ND 70919 E Issue 1 0 CHAPTER 4 CIRCUIT CARD INFORMATION PZ M557 CONN Switch Settings SWITCH SETTING SWITCH NAME NUMBER POSITION FUNCTION For coaxial connectors No 0 circuit For champ connector LT connector No 0 circuit For coaxial connectors No 1 circuit For champ connector LT connector No 1 circuit
70. OR CR a m e n 115 Programming SUMMA ect bas erdiaren airan kirE nE ENE E EREE E e BE n EE RS 115 MUMS ing Plan Programming sisriecresirerinr Gta me EUER EHE EE TRU ERE ud es 117 BRI TUAR FOGAM os cree eec p REP ES EM R 118 Home Side Trunk Programming 122 Mate Side Trunk Programming exa erid kerr kS eke badge 124 Incoming Termination for Event Based CCIS Calls 131 Access Code Terminating Number Assignment for Outgoing Event Based Calls 132 Release Timer for Virtual Tie Lines Home Side and Mate Side Trunks 133 BOIS ASSON co eh a DIRMI EC EN Ced E 134 Tandem Connection Programming 135 Closed Numbering Plan Programming AT RA RE RO 136 CHAPTER 4 CIRCUIT CARD INFORMATION 0 000 cece eee eee 137 HOW TO READ THIS CHAPTER o i cda dr d thacidd Eo Eder BAR ied Re kei a 138 MOUNTING LOCATION OF CIRCUIT CARD 0000 cee eee 139 LIST OF REQUIRED CIRCUIT CARDS 140 PNGP IOMP erar sere eared debe 3 372 9 0500 141 eeu eee eae C Re ee RR 146 oer ne re ee ee ede ree ee ee ee eee 151 DTI DP 156 xi 500 T0 aee a E E E A 162 PN 24PRTA PRT E ERI TAR Ena PR EN het 168 xig iR Fs PP eee ee ee ee ee ee ey ee 174
71. PN CP14 MP card on the MP12 slot on PIMO 2 The following application processor cards can be mounted the APOO AP11 slots on PIMO 7 PN BRTA BRT PN 2BRTC BRT PN 24DTA C DTI PN 30DTC A DTI PN 24PRTA PRT PN SCO00 CCH PN SCO01 DCH PN SCO03 ICH 3 PN ILCA ILC card on the LTOO LTO7 slots on PIMO 7 4 PZ M542 PZ M557 CONN card the LTCO LTC3 connectors on the PIM which accommodates 30 DTI card NEAX2000 IVS ISDN System Manual ND 70919 E Issue 1 0 Page 139 CHAPTER 4 CIRCUIT CARD INFORMATION List of Required Circuit Cards LIST OF REQUIRED CIRCUIT CARDS Table 4 1 shows the required circuit cards that are explained in this section Table 4 1 List of Required Circuit Card EXTRACTION INSERTION WITH LAMP SWITCH POWER ON X PROVIDED X PROVIDED REFERENCE NOT NOT LEE PAGE PROVIDED PROVIDED oe NOT ALLOWED PN CP14 MP me PN BRTA BRT er PN 2BRTC BRT 95 PN 24DTA C Page 156 DTI PN 30DTC A Page 162 DTI PN 24PRTA Page 168 PRT PN SCO00 CCH Page 174 PN SCO01 DCH Page 177 PN SCO03 ICH Page 180 PZ M542 CONN Page 182 PZ M557 CONN Page 184 PN 2ILCA ILC Page 186 NAME FUNCTIONAL NAME MB Make Busy NEAX2000 IVS ISDN System Manual Page 140 ND 70919 E Issue 1 0 CHAPTER 4 CIRCUIT CARD INFORMATION PN CP14 MP PN CP14 MP Locations of Lamps Switches and Connectors RS1
72. Present 1 Calling Party Subaddress When a station has dialed an ISDN subscriber number the station number is automatically sent as a Calling Party Subaddress START DESCRIPTION Provide the system with Calling Party CMO08 Subaddress to ISDN 2 END Called Party Subaddress When the system has received a Called Party Subaddress Calling Station Number from an ISDN subscriber the system connects the call with the specified terminal START DESCRIPTION Specify the terminating system for Called CMOS Party Subaddress NOTE If CM35 YYY 143 is set to 0 for Event Based CCIS assign the second data to 0 555 5000 Calling Party Subaddress DATA 1 400 2 0 Sent TRK 4210 z Cao D A Dial 214 555 5000 4211 dy lt 4211 4212 4 Subaddress DATA 1 401 2 Station Call 1 lt q Terminating System assigned by CM30 YY 02 03 40 41 NEAX2000 IVS ISDN System Manual ND 70919 E Issue 1 0 Page 89 CHAPTER 3 SYSTEM DATA PROGRAMMING ISDN Feature Programming Trunk Provisioning Service Selection START DESCRIPTION DATA CM30 Assign the trunk route to the trunk number YYz0O Trunk Route Allocation assigned by 7 1 000 255 Trunk No assigned by CM07 YY 301 2 00 63 Route No END NEAX2000 IVS ISDN System Manual Page 90 ND 70919 E Issue 1 0 CHAPTER 3 SYSTEM DATA PROGRAMMING ISDN Feature Programming I
73. RSO CONN To CONNR connector on PZ M537 EXPMEM Lamp Indications FUNCTION Flashes at 120 IPM while this card is operating normally Remains lit while receiving clock signals to the PLO NEAX2000 IVS ISDN System Manual ND 70919 E Issue 1 0 Page 141 CHAPTER 4 CIRCUIT CARD INFORMATION PN CP14 MP Switch Settings CAUTION When the operating power is being supplied to this circuit card do not plug unplug this circuit card into from its mounting slot SWITCH SETTING SWITCH NAME NUMBER POSITION FUNCTION SW3 Rotary SW On Line Call processing is in progress Off Line Call processing is stopped port As per CM40 YY 08 Off Line Call processing is stopped I O port 9600 bps Fixed Off Line Call processing is stopped I O port 9600 bps Off Line Call processing is stopped I O port 19200 bps Off Line Call processing is stopped I O port 38400 bps Off Line Call processing is stopped I O port 57600 bps For clearing the office data For setting the resident system program Not used Continued NOTE 1 Set the groove on the switch to the desired position NOTE 2 Only when executing MP Program Download using the Software Activation Tool in MATWorX Studio set the SW3 to 5 8 NEAX2000 IVS ISDN System Manual Page 142 ND 70919 E Issue 1 0 CHAPTER 4 CIRCUIT CARD INFORMATION PN CP14 MP SWITCH SWITC
74. RTUAL TRUNK MATE SIDE FOR MATE SIDE COMMON SIGNALING VIRTUAL TRUNK CHANNEL VIRTUAL TRUNK HOME SIDE HOME SIDE TRK No 100 TRK No 100 TRK RT No 10 TRK RT No 10 ISDN SUBSCRIBER No ISDN SUBSCRIBER No 972 555 6701 972 555 7801 TRK No 001 TRK