Home

NEC Express5800/R110d-1E Appendix

image

Contents

1. Deal Method hex digit 0604 C000025C 0605 8000025D 0606 8000025E 0607 4000025F 0701 400002BD 0702 400002BE 0801 C0000321 Fatal Warning Warning Information Information Information Fatal Address Type 4 The temperature of Enclosure is Fatal level Address Type 5 An error happened to the Power Supply Unit of Enclosure Address Type 6 An error happened to the Fan Unit of Enclosure Address Type 4 The temperature of Enclosure is Normal level Address Type 1 The Configuration was cleared raidsrv Configuration CTRL 1 ID 2 Vendor Product Firmware Version LD 3 ID 4 RAID RAIDlevel PD X Y Z count of LD STS Status PD 5 ID 6 ENC 7 SLT 8 Vendor Model Firmware Version STS Status 1 Number of RAID Controller 2 ID of RAID Controller 3 Number of Logical Drive 4 ID of Logical Drive 5 Number of Physical Device 6 ID of Physical Device 7 Enclosure Number of Physical Device 8 Slot Number of Physical Device X Y Z Number of Physical Device used in Logical Drive There is not the STS of PD when the device type is not HDD or HDD SSD It became unable to manage the RAID System due to a fatal error on the operating system RO MA RO MA RO MA RO MA RO M 0 RO MA Enclosure Temperature Fatal Enclosure Power Supply Unit Error Enclosure Fan Unit Error Enclosure Temperature Normal Configuration Cleared
2. Operating System Fatal Error Please check the Fan Unit of the Enclosure If some kind of problem happens to the Fan Unit please deal with the problem Please check the Power Supply Unit of the Enclosure If some kind of problem happens to the Power Supply Unit please deal with the problem Please check the Fan Unit of the Enclosure If some kind of problem happens to the Fan Unit please deal with the problem None None Please solve the fatal error on operating system This event is reported by insufficient free memory space insufficient free disk space or any other causes Please refer Universal RAID Utility User s Guide for detail 1 This item may not include in log message by the type of RAID Controller
3. RO RO RO RO RO RO RO MA MA MA MA MA MA MA MA MA Physical Device Ready Physical Device Hot Spare Physical Device Failed S M A R T Error Rebuild Started Rebuild Completed Rebuild Failed Rebuild Stopped Physical Device Inserted Physical Device Removed Physical Device Warning Physical Device Fatal Physical Device Medium Error Correctable Physical Device Medium Error Uncorrectable None None Please replace the Physical Device Please replace the Physical Device None None Please replace the Physical Device None None None Please check the Physical Device If some kind of problem happens to the Physical Device repeatedly please replace it Please replace the Physical Device Please replace the Physical Device if too many errors are detected on a Physical Device Please replace the Physical Device if too many errors are detected on a Physical Device Event ID Severity Description Deal Method hex digit 0322 40000142 0323 40000143 0324 80000144 0401 40000191 0402 80000192 0403 C0000193 0404 40000194 0405 40000195 0406 C0000196 0407 40000197 0409 40000199 0410 40000194A 0411 C000019B 0412 40000190C Information Information Warning Information Warning Fatal Information Information Fatal Information Information Information Fatal Information Address
4. 0312 40000138 0313 40000139 0314 40000134A 0315 4000013B 0316 40000130C 0317 8000013D 0318 C000013E 0319 4000013F 0320 C0000140 0321 40000141 Information Information Fatal Warning Information Information Fatal Information Information Information Information Information Information Information Warning Fatal Information Fatal Information Address Type 2 Physical Device is Ready Address Type 2 Physical Device is Hot Spare Address Type 2 Physical Device is Failed Address Type 2 Detected S M A R T Error Address Type 2 Rebuild was started Address Type 2 Rebuild completed Address Type 2 Rebuild failed Address Type 2 Rebuild was stopped Address Type 2 Physical Device was inserted Address Type 2 Physical Device was removed Address Type 2 Global Hot Spare created Address Type 2 Dedicated Hot Spare created Address Type 2 Global Hot Spare removed Address Type 2 Dedicated Hot Spare removed Address Type 2 A Warning Error happened to Physical Device Detail 1 Address Type 2 A Fatal Error happened to Physical Device Detail 1 Address Type 2 Medium Error was detected in Physical Device and corrected 1 Address Type 2 Medium Error was detected in Physical Device but could not correct 1 1 Logical Block Address Address Type 2 Rebuild was paused RO RO RO RO RO
5. 1 Address Type 1 Auto Patrol Read function is enable Address Type 1 Auto Patrol Read function is disable Address Type 1 A Patrol Read Priority of RAID Controller was changed Value 1 Address Type 1 Patrol Read was started Address Type 1 Patrol Read completed Address Type 1 A Warning Error happened to RAID Controller Detail 1 Address Type 1 A Fatal Error happened to RAID Controller Detail 1 Address Type 1 Patrol Read was paused Address Type 1 Patrol Read was resumed Address Type 1 Patrol Read was queued Address Type 1 Patrol Read was stopped Address Type 1 Patrol Read failed Address Type 2 Physical Device is Online RO RO RO RO M MA MA M RAID Controller Warning RAID Controller Fatal Patrol Read Failed Physical Device Online Please check the RAID Controller If some kind of problem happens to the RAID Controller repeatedly please replace it Please replace the RAID Controller Please disable the setting of Patrol Read and then enable it to retry Patrol Read If Patrol Read fails again the RAID System may have some problems Please deal with the problem of the RAID System and retry Patrol Read None Event ID Severity Description Deal Method hex digit 0302 4000012E 0303 4000012F 0304 C0000130 0305 80000131 0306 40000132 0307 40000133 0308 C0000134 0309 40000135 0311 40000137
6. Type 2 Rebuild was resumed Address Type 2 Rebuild was queued Address Type 2 Medium Error was detected in Physical Device 1 1 Logical Block Address Address Type 3 Logical Drive is Online Address Type 3 Logical Drive is Degraded Address Type 3 Logical Drive is Offline Address Type 3 Initialization was started Address Type 3 Initialization completed Address Type 3 Initialization failed Address Type 3 Initialization was stopped Address Type 3 Consistency Check was started Address Type 3 Consistency Check completed Address Type 3 Consistency Check failed Address Type 3 Consistency Check was stopped RO RO RO RO RO RO MA MA MA MA MA Physical Device Medium Error Detected Logical Drive Online Logical Drive Degraded Logical Drive Offline Initialization Failed Consistency Check Failed Please replace the Physical Device if too many errors are detected on a Physical Device None If there is Hot Spare RAID System will rebuild automatically If there is not it please replace the Physical Device and rebuild it Please replace the Physical Device and remake the Logical Drive Next restore the backup data to the Logical Drive Please retry Initialization If Initialization failed repeatedly the RAID System may have some kind of problem Please deal with the problem of the RAID System Please retry Consistency Check If Cons
7. Appendix C Logs Events The list of log and event alert messages that Universal RAID Utility logs to RAID Log and OS Log Event Source Alert Type Source Name of Event Log only Windows raidsrv Alert Type URAIDUTL Log R Universal RAID Utility logs this event to RAID Log 0 Universal RAID Utility logs this event to OS log Alert a scion M and MA Universal RAID Utility send this event to NEC ESMPRO Manager as alert Address description in Description The Address description is different from the category of event Category of Event Type Description RAID Controller 1 CTRL 1 ID 2 Battery 1 Number of RAID Controller 2 ID of RAID Controller Physical Device 2 CTRL 1 ID 2 PD 3 ID 4 ENC 5 SLT 6 7 8 1 Number of RAID Controller 2 ID of RAID Controller 3 Number of Physical Device 4 ID of Physical Device 5 Enclosure Number of Physical Device 6 Slot Number of Physical Device T Vendor and Model of Physical Device 8 Firmware Version of Physical Device Logical Drive 3 CTRL 1 ID 2 LD 3 ID 4 1 Number of RAID Controller 2 ID of RAID Controller 3 Number of Logical Drive 4 ID of Logical Drive Enclosure 4 CTRL 1 ID 2 ENC 3 1 Number of RAID Controller 2 ID of RAID Controller 3 Number of Enclosure Power Supply Unit in Enclosure 5 CTRL 1 ID 2 ENC 3 POW 4 1 Number of RAID Controller 2 ID of RAID Controller 3
8. Number of Enclosure 4 Number of Power Supply Unit Fan Unit in Enclosure 6 CTRL 1 ID 2 ENC 3 FAN 4 1 Number of RAID Controller 2 ID of RAID Controller 3 Number of Enclosure 4 Number of Fan Unit priority facility The messages of Universal RAID Utility have the following priority and facility on Linux or VMware ESX kind priority facility information info daemon warning warning daemon error err daemon Event ID Severity Description Deal Method hex digit 0201 400000C9 0202 400000CA 0203 400000CB 0204 400000CC 0205 400000CD 0206 400000CE 0207 400000CF 0208 400000D0 0209 400000D1 0210 400000D2 0211 800000D3 0212 C00000D4 0213 400000D5 0214 400000D6 0215 400000D7 0216 400000D8 0217 C00000D9 0301 4000012D Information Information Information Information Information Information Information Information Information Information Warning Fatal Information Information Information Information Fatal Information Address Type 1 The buzzer of RAID Controller is enable Address Type 1 The buzzer of RAID Controller is disable Address Type 1 The Rebuild Priority of RAID Controller was changed Value 1 Address Type 1 The Consistency Check Priority of RAID Controller was changed Value 1 Address Type 1 The Initialize Priority of RAID Controller was changed Value
9. al Drive Detail 1 1 Detail information Address Type 3 Initialization was paused Address Type 3 Initialization was resumed RO RO RO RO RO RO RO MA MA MA MA MA Data Inconsistency Error Corrected Cache Mode Changed Background Initialization Failed Logical Drive Uncorrectable Error Logical Drive Corrected Error Logical Drive Warning Logical Drive Fatal Please execute Consistency Check again when the load of the system is low If the error does not occur on the second time of Consistency Check the Physical Device does not have any problems If the same error occurs please replace the Physical Device for the preventive maintenance please be sure to ask NEC customer service before the replacement to identify which Physical Device has a failure After replacing the Physical Device restore the backup data to the Logical Drive None The RAID System may have some kind of problem Please deal with the problem of the RAID System Please replace the Physical Device You need to ask it which Physical Device do you replace After replacement of Physical Device remake the Logical Drive and restore the backup data to it Please replace the Physical Device for the prevention of failure You need to ask it which Physical Device do you replace Next restore the backup data to the Logical Drive after replacement of Physical Device The RAID Controller and or the Physical Devic
10. dress Type 1 The voltage of Battery is low Address Type 1 A Fatal Error happened to Battery Address Type 1 The Battery state is unstable Address Type 1 The voltage of Battery is normal Address Type 4 A Warning Error happened to Enclosure Address Type 4 A Fatal Error happened to Enclosure Address Type 4 The temperature of Enclosure is Warning level RO RO RO RO RO RO RO RO RO RO MA MA MA MA Battery Disconnect Battery Temperature Normal Battery Temperature High Battery Voltage Low Battery Fatal Battery Voltage Normal Enclosure Warning Enclosure Fatal Enclosure Temperature Warning Please check the Battery If some kind of problem happen to the Battery repeatedly please replace it Please check the Battery If some kind of problem happens to the Battery repeatedly please replace it Please check the Battery If some kind of problem happens to the Battery repeatedly please replace it Please replace the Battery None Please check the Enclosure If some kind of problem happens to the Enclosure repeatedly please deal with the problem of the Enclosure Please check the Enclosure If some kind of problem happens to the Enclosure repeatedly please deal with the problem of the Enclosure Please check the Fan Unit of the Enclosure If some kind of problem happens to the Fan Unit please deal with the problem Event ID Severity Description
11. e may have some kind of problem You need to ask it which component has broken The RAID Controller and or the Physical Device may have some kind of problem You need to ask it which component has broken Event ID Severity Description Deal Method hex digit 0428 400001AC 0429 400001AD 0430 400001 AE 0431 400001 AF 0432 400001B0 0433 400001B1 0434 400001B2 0501 400001F5 0502 800001F6 0503 400001F7 0504 400001F8 0505 800001F9 0506 800001FA 0507 800001FB 0508 800001FC 0509 400001FD 0601 80000259 0602 COO0025A 0603 8000025B Information Information Information Information Information Information Information Information Warning Information Information Warning Warning Warning Warning Information Warning Fatal Warning Address Type 3 Initialization was queued Address Type 3 Consistency Check was paused Address Type 3 Consistency Check was resumed Address Type 3 Consistency Check was queued Address Type 3 Background Initialization was paused Address Type 3 Background Initialization was resumed Address Type 3 Background Initialization was queued Address Type 1 Battery was detected Address Type 1 Battery was disconnected Address Type 1 Battery was replaced Address Type 1 The temperature of Battery is normal Address Type 1 The temperature of Battery is high Ad
12. istency Check failed repeatedly the RAID System may have some kind of problem Please deal with the problem of the RAID System Event ID Severity Description Deal Method hex digit 0413 C000019D 0415 4000019F 0416 40000140 0417 400001A1 0418 400001A2 0419 400001A3 0420 800001A4 0421 400001A5 0422 COO001A6 0423 400001A7 0424 800001A8 0425 COO001A9 0426 400001AA 0427 400001AB Fatal Information Information Information Information Information Warning Information Fatal Information Warning Fatal Information Information Address Type 3 Data Inconsistency was detected in Logical Drive by Consistency Check and corrected Address Type 3 Logical Drive was created Address Type 3 Logical Drive was deleted Address Type 3 The Cache Mode of Logical Drive was changed Value 1 1 Changed value 1 Address Type 3 Background Initialization was started Address Type 3 Background Initialization completed Address Type 3 Background Initialization failed Address Type 3 Background Initialization was stopped Address Type 3 An error was detected in Logical Drive but could not correct Address Type 3 An error was detected in Logical Drive and corrected Address Type 3 A Warning Error happened to Logical Drive Detail 1 1 Detail Information Address Type 3 A Fatal Error happened to Logic

Download Pdf Manuals