Home

NEC Express5800/GT110d-S User's Guide

image

Contents

1. 7 6 fl 8 SEE d TOT 10 l EE 10 L T j I 13 11 11 9 12 PEPER ABEE EDH 1 AC inlet 7 BMC RESET switch M RESET This socket is used to connect the power cord The switch to reset BMC of this server Use the switch only 2 PCI slots when there is something wrong with EXPRESSSCOPE 3 Chassis lock Engine 3 BMC The lock is provided to protect internal components from 8 USB connectors theft These connectors are used to connect devices that support a the USB interface 9 LAN connectors 1000BASE T 100BASE TX 10BASE T supported Ethernet connectors to connect to network system over LAN 10 Management LAN port 4 Serial port A connector An Ethernet connector which supports 100BASE TX This This connector is used to connect devices that support a port is used for connection with EAPRESSSEORE Engine serial interface Note that it is not possible to directly 3 and cannot be used as a data transmission port connect to a dedicated line If the N8117 01A additional 11 LINK ACT LED gr en RS232C connector kit available as an option is The LED indicates the access status of LAN connected the connector at N8117 01A will be the serial 12 Speed LED green amber port B connector The LED indicates the transfer speed of LAN ports 5 Monitor connector 13 Speed LED green The connector to c
2. 2 Engage the tabs of the bracket with the grille of the blank cover and fix it with the attached screw large Refer to the image below for the installation position 66 Express5800 GT110d S User s Guide Chapter 2 Preparations 1 Installing Internal Optional Devices 3 While pushing the blank cover to the right fix it with one screw If the cable is too long arrange it neatly such as by coiling once within the chassis Express5800 GT110d S User s Guide 67 Chapter 2 Preparations 1 Installing Internal Optional Devices Connecting to a RAID Controller 1 Connect another connector of the battery control cable to the connector board on the RAID Controller Check the orientation of the connector and connect the cable straight into the connector Be careful not to press it in at an angle when connecting Orientation of the connector Orient and connect the cable so that the markings on the connector and cable fit each other Marking 68 Express5800 GT110d S User s Guide Chapter 2 Preparations 1 Installing Internal Optional Devices 2 Install a RAID Controller into the PCI slot and fix it in place Be careful not to disconnect any cables 3 4 Putthe removed parts back Express5800 GT110d S User s Guide 69 Chapter 2 Preparations 1 Installing Internal Optional Devices 1 9 3 Installing N8103 141 extra battery Install an extra battery in the server by using the following procedure
3. 6 Make sure that you are properly inserting the bracket edge into the frame guide and attach it securely 88 Express5800 GT110d S User s Guide Chapter 2 Preparations 1 Installing Internal Optional Devices 7 Bendthe cable so as not to buffer other PCI cards and connect to the COM connector used for internal connections in the motherboard Refer to the following for the position of the COM connector for internal connections Important COM connector for internal connections 8 Make sure that no removed slot covers tools screws or other similar objects remain inside and assemble Express5800 GT110d S User s Guide 89 Chapter 2 Preparations 1 Installing Internal Optional Devices 4 11 3 5 inch Hard Disk Drive Up to 2 SATA Hard Disk Drives can be installed in the 3 5 inch Hard Disk Drive model Important Hard Disk Drive second Hard Disk Drive first 90 Express5800 GT110d S User s Guide Chapter 2 Preparations 1 Installing Internal Optional Devices 1 11 1 Installation Follow the procedure below to install the 3 5 inch Hard Disk Drive 1 Referto the manual provided with the Hard Disk Drive before installation and specify the settings of the Hard Disk Drive Number of Location of the bay additional where the drives will be Serial ATA connector of the connecting motherboard drives installed Serial ATA conn
4. Filling out the date on the Set up date label Write down n the installation date year and month on the Set up date label supplied with the extra battery Attach the label on the battery cover or somewhere easy to find on the server Fill out the Set up date label supplied with the battery Set up Date Y2010 M 04 Important Installing the battery in the server This section describes how to install an extra battery in the server Note that the installation position and procedure differ for 2 5 inch Hard Disk Drive models and 3 5 inch Hard Disk Drive models Installing the battery pack Installing the battery pack in the 2 5 inch Hard Disk Drive model in the 3 5 inch Hard Disk Drive model Getting ready to install the battery 1 Referto Chapter 2 1 3 Overview of Installation and Removal for preparations 2 While referring to Chapter 2 1 4 Removing the Side Cover and 1 5 Removing the Front Bezel remove the side cover and front bezel 3 Ifa RAID Controller is installed remove the center bar to disconnect the internal SAS cable and remove the RAID Controller For details refer to Chapter 2 1 10 PCI Cara 70 Express5800 GT110d S User s Guide Chapter 2 Preparations 1 Installing Internal Optional Devices Installing the connection board Install the connection board to the RAID Controller 1 Orient the remote battery connection board so that it will fit the connector on the RAID Controller and fix it wi
5. Do not leave the optical disk drive tray open Dust may get in the server when the tray is open which may result in a malfunction In addition bumping the open tray could cause personal injury Do not get yourself caught in the fan Keep your hands and hair away from the cooling fan at the rear of the server during operation Failure to observe this warning may cause your hands or hair to catch in the fan resulting in personal injury Express5800 GT110d S User s Guide 19 Precautions for Use Be Sure to Read Warning labels Warning label are attached on or near the components with potential hazards This label is either attached or printed on the component to draw attention from users to potential hazards involved in handling the server Do not remove or black out this label and keep it clean If no label is attached or printed on the server or if there is a label coming off or stained contact the store where you purchased the product 20 A XX CAUTION IPJI hTERT RETRETTEN SEEM BTRFREARRANL Do not put your finger in the air duct to lift this product A XE CAUTION Ive FRIES LIA OD MATE Ke o C d 5kgbL EO Ree RNC T US AF ROEBESDOKSUEBCASKGELT WAEEAMLAESKGU EMM The withstand load when this product is put in side is less than 5kg Do not put the thing of 5kg or more W Sy raat N ay NN e N Eu AN A i i CAUTION ATY a LOW BLR E
6. 12 Run the BIOS setup utility and confirm that the Hard Disk Drive is properly recognized from BIOS refer to Chapter 3 2 System BIOS Setup 92 Express5800 GT110d S User s Guide Chapter 2 Preparations 1 Installing Internal Optional Devices 1 11 2 Removal You can remove the Hard Disk Drive by using the following procedure Important 1 Refer to Chapter 2 1 3 Overview of Installation and Removal for preparations 2 Remove the side cover and front bezel while referring to Chapter 2 1 4 Removing the Side Cover and 1 5 Removing the Front Bezel 3 Take out the 3 5 inch Hard Disk Drive tray with the Hard Disk Drives installed referring to steps 3 to 9 in Chapter 2 1 11 1 Installation 4 Remove the Hard Disk Drive while referring to step 10 in Chapter 2 1 11 1 Installation 5 Assemble the server Express5800 GT110d S User s Guide 93 Chapter 2 Preparations 1 Installing Internal Optional Devices 1 12 2 5 inch Hard Disk Drive The standard number of SAS SATA Hard Disk Drives or solid state drives SSDs you can install in a 2 5 inch Hard Disk Drive is three and the maximum is five Combining SATA SAS Hard Disk Drives and SSDs e Hard Disk Drives SATA SAS and SSDs cannot be combined on BTO servers e A RAID Controller option must be prepared to use SAS Hard Disk Drives together with SSDs e You cannot mix them within the same RAID group Disk Array e You cannot use a combination of Hard Disk Drives
7. Also observe the following notes on using and connecting an interface cable Do not use any damaged cable connector Do not step on the cable Do not place any object on the cable Do not use the server with loose cable connections Do not use any damaged cable Express5800 GT110d S User s Guide 17 Precautions for Use Be Sure to Read Cleaning and working with internal devices A WARNING Do not disassemble repair or alter the server Never attempt to disassemble repair or alter the server on any occasion except as described in this document Failure to follow this warning may cause not only malfunction of the server but also an electric shock or fire Do not look into the optical disk drive A laser beam used in the optical disk is harmful to the eyes Do not look into or insert a mirror into the drive while the drive is powered on If a laser beam which is invisible enters your eyes you may lose your eyesight Do not attempt to remove lithium NiMH or Li ion batteries The server contains the lithium NiMH or Li ion battery some optional devices have a lithium NiMH or Li ion battery installed Do not remove the battery Placing a battery close to a fire or in the water may cause an explosion When the server does not operate appropriately due to the dead battery contact the store you purchased the product or your maintenance service company Do not attempt to disassemble the server to replace or recharg
8. Card performance PCI EXPRESS 2 0 x8 N8103 129 RAID Controller 256 MB RAID 0 1 Connects with internal drives Card performance PCI EXPRESS 2 0 x8 Can mount internal battery N8103 121 N8103 130 RAID Controller 256 MB RAID 0 1 5 6 Card performance PCI EXPRESS 2 0 x8 N8104 134 1000BASE T connection board 2 ch For adding LAN Card performance PCI EXPRESS x4 Teaming AFT SFT ALB and bonding with N8104 134 and on board LAN is supported Up to 2 teams per system Up to 2 ports per team O Can be installed Cannot be installed Model name Remarks name 1 Lane Indicates the transfer performance transfer bandwidth e g 1 lane 2 5 Gbps unidirectional 4 lanes 10 Gbps unidirectional Socket Indicates the connector size A card up to the number of sockets can be connected lt e g gt x4socket x1card x4card can be installed x8 card cannot be installed 2 The N8117 01A expansion RS 232C connector kit contains two types of cables This server uses the RS 232C cable B e The depth of mountable boards is up to 167 6 mm MD2 e For details of functions of each card refer to the technical guide e The card performance described in the parentheses after the Product name indicates the maximum operation performance of the card e Even if you use PCI cards of a higher performance than the PCI slot the operation of the device will be that of the PCI slot About the standard network
9. electricity when installing or removing any optional devices e Wear a wrist strap an arm belt or anti static glove Wear a wrist strap on your wrist If no wrist strap is available touch an unpainted metal part of the cabinet before touching a component to discharge static electricity from your body Also discharge static electricity by periodically touching a metal surface while working on the components e Select a suitable work space Work with the server on the anti static or concrete floor When you work with the server on a carpet where static electricity is likely to be generated be sure to take anti static measures beforehand e Use a work table Place the server on an anti static mat to work with e Clothing Do not wear wool or synthetic clothes Wear anti static shoes Take off any jewels a ring bracelet or wrist watch before working with the server e Handling of components Keep any component in an anti static bag until you actually install it to the server Hold any component by its edge to avoid touching any terminals or parts To store or carry any component place it in an anti static bag Express5800 GT110d S User s Guide 45 Chapter 2 Preparations 1 Installing Internal Optional Devices 1 3 Overview of Installation and Removal 46 Install remove components by using the following procedure 1 2 3 4 5 6 7 8 9 If the server is ON tu
10. modify or repair the power cord Uncoil the power cord before use Do not use a damaged power cord replace the Do not secure the power cord with staples or damaged power cord with a power cord of the same standard For information on replacing the power cord contact the store where you purchased the product or a maintenance service company equivalents Do not use the attached power cord for any other devices or usage The power cord that comes with your server is designed aiming to connect with this server and to use with the server and its safety has been tested Do not use the attached power cord for any other purpose Doing so may cause a fire or an electric shock Express5800 GT110d S User s Guide Precautions for Use Be Sure to Read Installation relocation storage and connection Do not attempt to lift the server by holding the front bezel or air duct Securely hold the server by the base to move or lift Do not attempt to lift it by holding the front bezel or air duct Doing so may cause the front bezel or air duct to come off which may cause not only breakage of the server but also cause the server to fall on to persons resulting in personal injury Do not install the server in any place other than specified Do not install the server in the following places or any place other than specified in this User s Guide Failure to follow this instruction may cause a fire e A dusty place e A humid place such as near
11. 0 mm width x 396 5 mm depth x 386 5 mm height air duct stabilizer protrusions included 100 200 VAC 10 50 60 Hz 3Hz zw Temperature 10 to 40 C Humidity 20 to 80 and no condensation conditions When in storage Temperature 10 to 55 C Humidity 20 to 80 and no condensation Supported OSs Windows Server 2008 R2 Standard Windows Server 2008 R2 Enterprise Windows Server 2008 R2 Foundation Windows Server 2008 Standard Windows Server 2008 Enterprise Windows Server 2003 R2 Standard x64 Edition Windows Server 2003 R2 Standard Edition Windows Server 2003 Standard Edition Red Hat Enterprise Linux 5 Server x86 Red Hat Enterprise Linux ES 4 x86 Red Hat Enterprise Linux 5 Server EM64T Red Hat Enterprise Linux ES 4 EM64T Included parts 104 keyboard two button mouse with scroll wheel air duct rubber feet EXPRESSBUILDER DVD Getting Started screws for device Power code 1 For Linux OS onboard RAID feature is not supported 2 Can be optionally expanded to two ports 3 Service Pack or later 140 Express5800 GT110d S User s Guide Chapter 4 Appendix 1 Specifications 1 2 Water cooling System Specifications on shipment ay Clock cache Standard maximum Chipset Memory Auxiliary Hard Disk Drive storage standard Hard Disk Drive maximum Solid state drive Optical disk drive standard Expansion bay prem 3 5 inch disk bay Expansion slot PCI External inte
12. 1 to 5 in Chapter 2 1 3 Overview of Installation and Removal for preparations Hold the server with both hands and slowly and gently lay it so that the left side faces upward Rotate both levers of the target DIMM slot outward the way into the slot When the DIMM is inserted into the slot the lever automatically closes Hold the DIMM vertically and push it all D N Key slot Key Important Note Firmly close the lever Continue to install or remove internal optional devices mount and connect the server and turn it on Confirm that no error messages are displayed in POST screen If any error messages are displayed refer to Chapter 3 1 POST Error Message in Maintenance Guide Run the SETUP Utility go to the Advanced menu and check the display in Memory Configuration Confirm that the added DIMM has been recognized in the BIOS Confirm that the applicable DIMM Group Status is set to Normal Refer to Chapter 2 1 Details of System BIOS in Maintenance Guide Set the paging file size to the recommended value Total memory size x 1 5 or more If using a Windows OS refer to Chapter 1 7 1 Specifying Memory Dump Settings Debug Information in Installation Guide Windows For other OS consult the manual provided with the operation system or contact the store where you purchased it or your maintenance service company Express5800 GT110d S User s Guide Chapter 2 Preparations 1 Installing Inter
13. 192 168 0 3 Host Name HostName Domain Name DomainNamel lt OK gt lt Cancel gt lt Load Default Value gt 6 Connect the LAN cable to the management LAN connector in order to connect to the network It will be available for use if you access EXPRESSSCOPE Engine 3 via Web browser from PC for management according to the setting Express5800 GT110d S User s Guide 135 Chapter 3 Setup 4 EXPRESSBUILDER 4 EXPRESSBUILDER EXPRESSBUILDER helps you to install Windows or maintain the server A I Features of EXPRESSBUILDER EXPRESSBUILDER provides the following features Features Descriptions Setup Installs Windows on your server Easily completes the process from RAID configuration to installation of applications To use this feature select Os installation in the menu after boot Windows reinstallation Storage of software Stores various bundled software such as NEC ESMPRO Agent Maintenance Diagnoses your server system To use this feature select Tool menu in the menu after boot Storage of documents Stores various documents including User s Guide Installation Guide and Maintenance Guide Documents and some software components are not stored in N8115 05 Internal Flash Memory option 4 2 Starting EXPRESSBUILDER If you want to install Windows start EXPRESSBUILDER by using any of the following EXPRESSBUILDER DVD Set the DVD on the drive and either turn on
14. 2 Accessories Verify the condition of your server s accessories 3 Standard Features Check and maintain the server system by using the functions explained in this section 4 Names and Functions of Parts This section describes the name of each part contained in this server 24 Express5800 GT110d S User s Guide Chapter 1 General Description 1 Introduction EB Introduction Thank you for purchasing this NEC Express5800 Series product This high performance server is powered by the latest Intel processor The type of processor installed depends on the model e Intel Xeon processor e Intel Pentium processor e Intel Core i3 processor NEC s latest technology and architectures realize high power and high speed operation that cannot be matched by existing servers The server is designed with consideration of not only reliability but also expandability which enables you to use it as a network server Read this document before using the server thoroughly to fully understand handling of the NEC Express server and appreciate its functions to the maximum extent Express5800 GT110d S User s Guide 25 Chapter 1 General Description 2 Accessories 2 Accessories The carton box contains various accessories which are required for setup or maintenance Make sure you have them all for future use e SATA cable x 2 e Keyboard x 1 e Mouse x 1 e Air duct x 1 e Rubber foot x 4 e Security key x a e Screw
15. 4 1 Power supply unit 7 Motherboard 2 Water cooling unit for cooling CPU 8 Radiator cooling fan front 3 DIMM slots 9 Radiator cooling fan rear 4 3 5 inch Hard Disk Drive 10 Radiator 5 Optical disk drive 11 PCI slots 6 3 5 inch device bay 12 Rear fan Express5800 GT110d S User s Guide 35 Chapter 1 General Description 4 Names and Functions of Parts 2 5 inch Hard Disk Drive model air cooled type 11 10 12 9 1 Power supply unit 7 Optical disk drive 2 CPU cooling fan 8 3 5 inch device bay 3 DIMM slot 9 Motherboard 4 SAS backplane 10 PCI slot 5 2 5 inch Hard Disk Drive 11 Rear fan 6 HDD fan 12 Bottom fan 36 Express5800 GT110d S User s Guide Chapter 1 General Description 4 Names and Functions of Parts 2 5 inch Hard Disk Drive model water cooled type 14 12 11 10 9 1 Power supply unit 8 3 5 inch device bay 2 CPU cool
16. 503 x 1 e Screw 505 x 2 EXPRESSBUILDER e Getting Started e Power cord x 1 1 Only for 3 5 inch disk models The number of the cable depends on the Hard Disk Drive configuration 2 Only for 2 5 inch disk models 3 If an internal backup device is pre installed this is already attached 4 Documents are stored in EXPRESSBUILDER Adobe Reader is required to read the documents so make sure you have it installed in your PC Make sure you have all accessories and inspect them If an accessory is missing or damaged contact your sales representative 26 Express5800 GT110d S User s Guide Chapter 1 General Description 3 Standard Features JJ Standard Features The server has the following standard features High performance e Intel Xeon Pentium Core 3 processor e High speed memory access DDR3 1333 supported e High speed disk access SATA2 3 Gbps SAS 6 Gbps supported e High speed 1000BASE T 100BASE TX 10BASE T 2 ports interface 1 Gbps 100 Mbps 10 Mbps supported Sr ES Pentium G620 embedded models operate at 1066 MHz SY SS SS High reliability e Memory monitoring feature error correction error detection ES e Memory degeneracy feature logical isolation of a failed device SS e Bus parity error detection e Temperature detection e Error detection e Internal fan monitoring feature e Internal voltage monitoring feature e RAID System Disk Array also availabl
17. Doing so may cause an electric shock Keep water or foreign matter away from the server Do not let any liquid such as water or foreign materials including pins or paper clips enter the server Failure to follow this warning may cause an electric shock a fire or failure of the server When such things accidentally enter the server immediately turn off the power and disconnect the power plug from the outlet Do not disassemble the server and contact the store where you purchased the product or your maintenance service company 14 Express5800 GT110d S User s Guide Precautions for Use Be Sure to Read Power supply and power cord use A WARNING Do not hold the power plug with a wet hand Do not disconnect connect the plug while your hands are wet Failure to follow this warning may cause an electric shock Do not connect the ground wire to a gas pipe Never connect the ground wire to a gas pipe Failure to follow this warning may cause a gas explosion 44 CAUTION Plug in to a proper power source Use a grounded outlet and observe the specified voltage Use of an improper power source may cause a fire or a power leak Do not install the server where you need an extension cord Use of a cord that does not meet the power specifications of the server may heat up the cord and cause a fire If you want to use an AC cord set with a ground wire of class Ol be sure to connect the ground wire before inserting the power plug
18. GT110d S User s Guide 127 Chapter 3 Setup 1 Turning on the Server 1 1 2 POST Error Messages When POST detects an error it displays an error message on the screen or beeps for some errors For descriptions of error messages causes and countermeasures refer to Maintenance Guide Important 128 Express5800 GT110d S User s Guide Chapter 3 Setup 2 System BIOS Setup 2 System BIOS Setup This section describes how to configure Basic Input Output System BIOS Before you install the server and add or remove optional devices make sure you have read and understood this section to configure properly 2 1 Overview SETUP is a utility to do basic hardware settings This utility is pre installed in the Internal Flash Memory in the server as standard and can be run without requiring a media for boot In most of cases the SETUP was configured for optimal performance before the server was shipped to you Therefore in most of cases you should not need to use the SETUP utility Use only when the case applies to any of cases described in Chapter 3 2 4 Cases that Require Configuration 2 2 Starting SETUP Utility Run POST following Chapter 3 1 1 1 POST sequence After a while the following message will be displayed on the lower left of the screen Press F2 SETUP F3 Internal Flash Memory F4 ROM Utility F12 Network If you press the F2 key at this time SETUP runs and displays the Main
19. HDD cage Slot 5 Fifth Hard Disk Drive Slot 4 Fourth Hard Disk Drive When 5 Hard Disk Drives are installed To install five Hard Disk Drives a RAID Controller is required You cannot connect them to the on board SATA controller Express5800 GT110d S User s Guide 109 Chapter 2 Preparations 1 Installing Internal Optional Devices 2 Connecting 3 5 inch devices You can mount SCSI devices SAS devices and USB devices for internal connections to 3 5 inch devices a If mounting an SCSI device Use SCSI cable K410 181 00 with an SCSI controller to connect the SCSI device Set an SCSI ID that is not already set as the ID for another SCSI device Because a connector for terminating SCSI connections is installed in SCSI cable K410 181 00 specify the termination settings of the 3 5 inch device to Disabled Motherboard Optical disk drive SCSI controller Terminal i SCSI device CEIM SCSI cable K410 181 00 mmmmm SATA cable for use with the optical disk drive b If mounting an internal USB device Use the dedicated internal USB cable K410 255 00 Power supply unit Motherboard Optical disk drive Internal USB connector SCSI device c m9 USB cable K410 255 00 mmmmm SATA cable for use with the optical disk drive 110 Express5800 GT110d S User s Guide Chapter 2 Preparations 1 Installing Internal Optional Devices c If using the front USB con
20. RAID Controller 256 MB RAID 0 1 5 6 Hisl battery petes terr ep Sin Card performance PCI EXPRESS 2 0 x8 Successor can be Installec N8104 134 1000BASE T connection board 2 ch For adding LAN Card performance PCI EXPRESS x4 Teaming AFT SFT ALB and bonding with N8104 134 and on board LAN is supported Up to 2 teams per system Up to 2 ports per O Can be installed Cannot be installed Model name Remarks name 1 Lane Indicates the transfer performance transfer bandwidth e g 1 lane 2 5 Gbps unidirectional 4 lanes 10 Gbps unidirectional Socket Indicates the connector size A card up to the number of sockets can be connected lt e g gt x4socket x1card x4card can be installed x8 card cannot be installed 2 The N8117 01A expansion RS 232C connector kit contains two types of cables This server uses the RS 232C cable B e The depth of mountable boards is up to 167 6 mm MD2 e For details of functions of each card refer to the technical guide e The card performance described in the parentheses after the Product name indicates the maximum operation performance of the card e Even if you use PCI cards of a higher performance than the PCI slot the operation of the device will be that of the PCI slot About the standard network You can use functional equivalents of AFT SFT ALB teaming with the standard network and the following LAN cards N8104 134 Express5800 GT110d S Us
21. Xeon Intel Pentium Intel Xeon processor G620 processor E3 1220 processor G620 processor E3 1220 Clock cache 2 60 GHz 3 MB 3 10 GHz 8 MB 2 60 GHz 3 MB 3 10 GHz 8 MB Standard Not pre installed 1 maximum Chipset Intel C204 Chipset Standard Not pre installed 52 68 8 68x4 DDR3 1333 SDRAM DIMM unbuffered x 1 Memory module ECC DDR3 1333 SD RAM DIMM with dual channel memory support Graphics Integrated in BMC more than 32 MB Auxiliary Hard Disk Drive Not pre installed storage standard Hard Disk Drive 3 5 inch SATA 4 TB 2 TB x 2 2 5 inch SATA 5 TB 1 TB x 5 maximum 2 5 inch SAS 3 TB 600 GB x 5 Solid state drive 2 5 inch SATA 500 GB 100 GB x 5 option Optical disk drive SATA RAID 0 1 standard option SATA RAID 0 1 standard RAID5 option SAS RAID 0 1 5 option Hard Disk Drive Standard DVD ROM drive standard Option DVD SuperMULTI drive replaces the DVD ROM drive Expansion bay Disk bay 3 5 inch Hard Disk Drive x 2 2 5 inch Hard Disk Drive x 5 option 3 5 inch disk bay 1 slot Expansion slot PCI PCI EXPRESS 1 slot x8 x8 socket PCI EXPRESS 2 slot x4 x8 socket 32 bit 33 MHzx1 slot External Front 2 ports rear 4 ports internal 2 ports version 2 0 compatible 2 ports 100Base T 100Base TS 10Base T RJ 45 Management LAN port RJ 45 External dimensions 93 0 mm width x 386 5 mm depth x 363 0 mm height not including air duct stabilizer protrusions 190
22. and connect the cable straight into the connector Orientation of the connector Orient the markings of the connector and cable to fit each other and then connect them Marking Important Express5800 GT110d S User s Guide 61 Chapter 2 Preparations 1 Installing Internal Optional Devices Installing the battery in the server This section describes how to install this product in the server Note that the installation position and procedure differ for 2 5 inch Hard Disk Drive models and 3 5 inch Hard Disk Drive models Preparation for installation Installing the connector board Installing the battery pack Installing the battery pack in the 2 5 inch Hard Disk Drive model in the 3 5 inch Hard Disk Drive model Connecting to RAID Controller Getting ready to install the battery 1 Refer to Chapter 2 1 3 Overview of Installation and Removal for preparations 2 While referring to Chapter 2 1 4 Removing the Side Cover and 1 5 Removing the Front Bezel remove the side cover and front bezel 3 Ifa RAID Controller is installed remove the center bar to disconnect the internal SAS cable and remove the RAID Controller For details refer to Chapter 2 1 10 PCI Cara Installing the connector board This section describes how to install the connector board to RAID Controller N8103 129 130 1 Securely connect the connector board to the connector of the RAID Controller and screw it with the attached screw small at th
23. display the NEC logo during POST Install RAID Controller board Change the boot order of devices Use remote power on function from modem Use remote power on function from RTC alarm Control from HW console terminal Set a password When the server is supplied with power from UPS always turn on the power If it is turned off by using POWER switch leave it OFF even when UPS supplies power Keep the power OFF even when UPS supplies power Boot gt Quite Boot gt Disabled By pressing the lt Esc gt key prevent the display of the logo Advanced gt PCI Configuration gt PCI n is PCI slot number of the Slot n Option ROM gt Enabled RAID Controller Boot gt Boot Option Priorities gt Change the boot priority Advanced gt Advanced Chipset Configuration gt Wake On Ring gt Enabled Advanced gt Advanced Chipset Configuration gt Wake On RTC Alarm gt Enabled Advanced gt Serial Port Configuration Change respective setting Security gt Administrator Password There are two types of gt Enter a password password Administrator and Set a password for Administrator first User and then User Settings for User password is limited compared to for Administrator Server gt AC LINK gt Power On Server gt AC LINK gt Last State Server gt AC LINK Remains off Express5800 GT110d S User s Guide Chapter 3 Setup 2 System BIOS Setup Password If you have set a pa
24. e EXPRESSBUILDER setup utility e SETUP BIOS SETUP utility Maintenance features e Off line maintenance utility e Memory dump feature using the DUMP switch e Feature to back up and restore BIOS BMC settings using the EXPRESSSCOPE profile key 28 Express5800 GT110d S User s Guide Chapter 1 General Description 3 Standard Features 3 1 Management Features The hardware components of the server provide operation control reliability features as shown below Additionally NEC ESMPRO Agent which is provided in EXPRESSBUILDER enables you to collectively manage the state of your systems You can also monitor the server states from a PC to manage the network where NEC ESMPRO Manager provided in EXPRESSBUILDER is installed The features available on this server are as shown in the table below Hardware pex Shows physical hardware information Memory bank 2 Shows physical memory information Device info Shows information specific to the server EA Shows physical CPU information System Shows logical CPU information and monitors the load factor Shows logical memory information and monitors the status I O device Shows information on l O devices serial ports keyboard mouse and System environment Temperature Monitors the temperature inside of the chassis Fan Monitors the fans Voltage Monitors the voltage inside of the chassis Power supply Monitors the power supply unit Door Monitors chassis intrusion open
25. in water cooled models e LED cables attached to the K410 180 00 are not used If connecting a SATA Hard Disk Drive or solid state drive to an onboard SATA controller To connect a SATA Hard Disk Drive or solid state drive hereinafter referred to as Hard Disk Drive to the SATA controller the dedicated cable K410 241 00 is required Connect cables as instructed in the image below Match the number on the SATA connector of the cable with the SATA connector number on the motherboard Also connect the cable to the SGPIO connector on the motherboard Install Hard Disk Drives from Slot 0 in ascending order Express5800 GT110d S User s Guide Chapter 2 Preparations 1 Installing Internal Optional Devices When 3 Hard Disk Drives are installed for onboard connection ooo ooo 2222272955 SARETE aan MEHEEHIP h h Slot 2 Third Hard Disk Drive Slot 1 Second Hard Disk Drive Slot 0 First Hard Disk Drive Motherboard RAID Controller Optical disk drive N8103 128 129 130 134 Extra battery N8103 121 141 2 5 inch expansion HDD cage EE internal SATA cable K410 180 00 mmm Battery cable attached to the expansion battery p SATA cable for use with the optical disk drive 00000000 0000 00000000 0000 f 00000000 0000 00000000 0000 f cxx MB SASBP signal cable attached to the 2 5 inch expansion HDD cage mmm SATA cable attached to the 2 5 inch expansion
26. menu upon completion of POST You can also press the F2 key while the NEC logo appears to display the Main menu Express5800 GT110d S User s Guide 129 Chapter 3 Setup 2 System BIOS Setup 2 3 Description on On Screen Items and Key Usage This section shows display examples and how to control the key Use the keyboard to work with the SETUP utility Indicates the currently displayed menu Indicates the menu has submenus Help gt system Management Setting items Parameters highlighted when selected Items that cannot be specified are dimmed O Cursor keys lt P gt lt gt Select an item displayed on the screen If characters of an item are highlighted that means the item is currently selected O Cursor keys lt lt gt lt gt gt Select menus including Main Advanced Security Server Boot and Save amp Exit O lt gt key lt gt key Change the value parameter of the selected item You cannot use this key when a menu which has gt on the left is selected O Enter key Press this key to confirm the selected parameter O Esc key Pressing this key takes you to the previous screen If you keep pressing the key the following window is displayed If you select Yes the SETUP closes without saving the changed parameters Quit without saving Yes No L F1 key Press this key to display help information If you need help using the SETUP press this ke
27. recognized in different order from that described above depending on OS or RAID System BIOS utility Check the slot location of PCI device by PCI bus number device number and function number shown in the table below PCI device Bus number Device number Function number Onboard NIC1 4 00 DE TENE E AAA AAA ET PERS ver aoa ir ps ERA Set Disabled for the optional ROM of a LAN device not to be booted by using the BIOS Setup utility If an additional bootable PCI card such as a RAID Controller SCSI controller or LAN card is installed the boot priority may change After the installation set the boot priority in the Boot menu of the BIOS Setup utility If a bootable device such as a PCI card or USB device is added the boot order may change In the BIOS Setup utility select Hard Drive BBS Priorities from the Boot menu and then specify a higher priority for the boot device Boot gt Hard Drive BBS Priorities gt Check the display If the boot device is an HDD under an optional RAID Controller the display is Bus xx Dev 00 PCI RAID Adapter Note that the value for xx changes depending on the PCI slot where a RAID board is installed Express5800 GT110d S User s Guide 79 Chapter 2 Preparations 1 Installing Internal Optional Devices 1 10 2 List of option devices and installation slots 3 5 inch Hard Disk Drive model air cooling system PCI EXPRESS 2 0 PCI PCI 1 PCI 2 PCI 3 PCI 4 32 bit PCI slot perform
28. step 5 7 Install the bracket with DVDSuperMULTI drive installed to the server 8 Connect the SATA cable you disconnected in step 4 to the server This completes the installation procedures 1 13 2 Removal You can remove the optical disk drive by reversing the installation procedure 100 Express5800 GT110d S User s Guide Chapter 2 Preparations 1 Installing Internal Optional Devices 1 14 Backup devices This server contains slots for the installation of backup devices such as optical disk drives and magnetic tape drives As a standard there is one expansion slot Tips Controller board options and internal cables might be required depending on the devices installed For more information refer to Chapter 2 1 15 Connecting cables Optical disk drive 3 5 inch device bay MI Express5800 GT110d S User s Guide 101 Chapter 2 Preparations 1 Installing Internal Optional Devices 1 14 1 Installation Install a backup device by using the following procedure The procedure will be described focusing on installing the SCSI file device option 1 Specify the settings of the device The settings for the device to be installed to the device bay is as follows Device Ll Settings SCSI device Termination resistor OFF Because the internal SCSI cable K410 181 00 available as an option is attached to the termina
29. that have differing rotation speeds for SAS Hard Disk Drives e Mount SATA SAS Hard Disk Drives in order from slot 0 and mount the SSDs to the remaining slots e You can use a combination of an SAS Hard Disk Drive in the standard cage and an SATA Hard Disk Drive in the expansion cage Important Hard Disk Drive slot O first Hard Disk Drive slot 0 first Hard Disk Drive slot 1 second Hard Disk Drive slot 1 second Hard Disk Drive slot 2 third Hard Disk Drive slot 2 third Hard Disk Drive slot 4 fourth Hard Disk Drive slot 5 fifth When 3 Hard Disk Drives are installed When 5 Hard Disk Drives are installed Important 94 Express5800 GT110d S User s Guide Chapter 2 Preparations 1 Installing Internal Optional Devices 1 12 1 Installing an expansion 2 5 inch HDD cage For 2 5 inch Hard Disk Drive models you can install an additional two Hard Disk Drives by using a 2 5 inch HDD cage Tips An expansion 2 5 inch HDD cage is only supported by air cooled models Install the 2 5 inch HDD cage for additional drives by using the following procedure 1 Refer to Chapter 2 1 3 Overview of Installation and Removal for preparations 2 Remove the side cover and front bezel while referring to Chapter 2 1 4 Removing the Side Cover and 1 5 Removing the Front Bezel 3 Pull the blank panel toward you while pressing the tab on the right 4 Remove
30. the Internal Flash Memory and fix it with the screw provided with this product 1 6 2 Removal To remove the Internal Flash Memory reverse the installation procedure Express5800 GT110d S User s Guide 49 Chapter 2 Preparations 1 Installing Internal Optional Devices 1 7 DIMM Install a DIMM Dual In line Memory Module to a DIMM slot on the motherboard in the server The motherboard provides four slots to install DIMMs Up to 32 GB 8 GB x 4 of memory can be installed Important Tips As about 750 MB of memory is used for PCI resources the available memory size may be less than the mounted memory size DIMM2 DIMM4 DIMM1 DIMM3 Rear Front Motherboard This server supports Dual Channel memory mode If you run the server in Dual Channel mode the data transfer speed of the memory doubles 50 Express5800 GT110d S User s Guide Chapter 2 Preparations 1 Installing Internal Optional Devices 1 7 1 Maximum supported memory size The maximum available memory size on the server depends on the architecture x86 architecture and OS specs A list of maximum memory sizes The maximum memory size The maximum memory size supported on each OS supported on the server Windows Server 2003 R2 Standard Edition 4 GB If using HW DEP function Windows Server 2008 Standard x86 Edition Default fa
31. the blank cover and fix it with the attached screw large Refer to the image below for the installation position 76 Express5800 GT110d S User s Guide Chapter 2 Preparations 1 Installing Internal Optional Devices 4 While pushing the blank cover to the right fix it with one screw If the cable is too long arrange it neatly such as by coiling once within the chassis This concludes the installation of the battery module in a 3 5 inch Hard Disk Drive model 1 94 Removal For removing the extra battery for the RAID Controller reverse the installation procedure Express5800 GT110d S User s Guide 77 Chapter 2 Preparations 1 Installing Internal Optional Devices 1 10 PCI Card This server provides four slots where PCI cards can be installed Important Tips PCIZ3 and PCIZ4 are not supported by water cooled models Motherboard 78 Express5800 GT110d S User s Guide Chapter 2 Preparations 1 Installing Internal Optional Devices 1 10 1 Notes Read the following notes when installing or removing a PCI card Do nat touch the terminals of cards and the leads of electronic components with your bare hand Fingerprints and dust left on them cause the server to malfunction due to a connection failure or damage to the leads The search order for PCI bus slot on boot is as follows Slot3 gt Slot1 gt Slot2 gt Slot4 The PCI devices of the same type including onboard PCI device may be
32. the connector size A card up to the number of sockets can be connected e g x4socket x1card x4card can be installed x8 card cannot be installed 2 The N8117 01A expansion RS 232C connector kit contains two types of cables This server uses the RS 232C cable B e The depth of mountable boards is up to 167 6 mm MD2 e For details of functions of each card refer to the technical guide e The card performance described in the parentheses after the Product name indicates the maximum operation performance of the card e Even if you use PCI cards of a higher performance than the PCI slot the operation of the device will be that of the PCI slot About the standard network You can use functional equivalents of AFT SFT ALB teaming with the standard network and the following LAN cards N8104 134 82 Express5800 GT110d S User s Guide Chapter 2 Preparations 1 Installing Internal Optional Devices 2 5 inch Hard Disk Drive model water cooling system PCI EXPRESS 2 0 PCI 1 PCI 2 Product Sese size Low Profile PCI card type socket socket Available card size card size Up to167 6 mm MD2 N8103 107 SCSI controlle Connects to internal and external devices Card performance PCI EXPRESS x1 N8103 128 RAID Controller 128 MB RAID 0 1 5 6 Connects with internal drives Card performance PCI EXPRESS 2 0 x8 Can mount internal battery N8103 141 450 N8103 134 RAID Controller 512 MB RAID 0 1 5 6 mm cable
33. the server or restart the server by pressing Ctrl Alt Delete EXPRESSBUILDER is booted from DVD N8115 05 Internal Flash Memory option During POST press F3 If you start with this option make sure that the media was removed from the drive 136 Express5800 GT110d S User s Guide Chapter 3 Setup 5 Installing Software Components J Installing Software Components Continue to install software components such as OS Refer to the instructions below e Installation Guide Windows Express5800 GT110d S User s Guide 137 Chapter 3 Setup 6 Turning Off the Server 6 Turning Off the Server Turn off the server by using the following procedure If the power cord of the server is connected to a UPS refer to the documentation supplied with the UPS or the documentation for the application controlling the UPS 1 Shut down the OS 2 If the server does not automatically power off press the POWER switch at the front of the server Confirm that POWER LED is OFF 3 Turn off peripheral devices 138 Express5800 GT110d S User s Guide 1 Specifications 2 Interrupt Lines Express5800 GT110d S User s Guide 139 Chapter 4 Appendix 1 Specifications I Specifications T IT hir cooling System Express5800 GT110d S EXP281A Product name N8100 1739F N8100 1740F Specifications on shipment 3 5 inch Hard Disk Drive model 2 5 inch Hard Disk Drive model PU Type Intel Pentium Intel
34. 003 R2 Standard Edition Windows Server 2003 R2 Enterprise Edition Windows Server 2003 Standard Edition Windows Server 2003 Enterprise Edition Windows PE 1 Service Pack2 or later 2 Used as an installation platform only Y Supported Not supported 8 Express5800 GT110d S User s Guide Trademarks Trademarks ESMPRO and EXPRESSSCOPE are registered trademarks of NEC Corporation Microsoft Windows Windows Server Windows Vista and MS DOS are registered trademarks or trademarks of Microsoft Corporation in the United States and other countries Intel Pentium and Xeon are registered trademarks of Intel Corporation of the United States AT is a registered trademark of International Business Machines Corporation of the United States and other countries Adaptec its logo and SCSI Select are registered trademarks or trademarks of Adaptec Inc of the United States LSI and the LSI logo design are trademarks or registered trademarks of LSI Corporation Adobe the Adobe logo and Acrobat are trademarks of Adobe Systems Incorporated DLT and DLTtape are trademarks of Quantum Corporation of the United States PCI Express is a trademark of Peripheral Component Interconnect Special Interest Group Linux is a trademark or registered trademark of Linus Torvalds in Japan and other countries Red Hat amp and Red Hat Enterprise Linux are trademarks or registered trademarks of Red Hat Inc in the United Stat
35. 103 121 extra battery e For N8103 128 134 use N8103 141 extra battery Handling precautions Below are the precautions to be observed whenever using the backup battery Be sure to observe the following otherwise property such as data or other devices might be destroyed e Use the extra battery that supports the RAID Controller used e The extra battery is a very delicate electronic device Before installation touch the metal frame part of the server to discharge the static electricity from your body e Do not drop or bump the backup battery e For recycling and disposing the backup battery refer to the user s guide that comes with it Installing N8103 121 extra battery Install an extra battery in the server by using the following procedure Note Read through the users guide supplied with the RAID Controller before installation Fill out the date on the label Fill out the date on the label Fill out the installation date on the setup date label supplied with the extra battery and attach it to the battery case s SUC fecu a E e Write the date Example Y 2007 M 12 cei e os lt in danger of explosion and heat up Express5800 GT110d S User s Guide Chapter 2 Preparations 1 Installing Internal Optional Devices Important Connecting the battery control cable Referring to the image below connect the battery control cable into the battery pack Check the orientation of the connector
36. 2 Preparations 1 Installing Internal Optional Devices 1 10 6 Installing the N8117 01A expansion RS 232C connector kit Install a PCI card to connect to the PCI slot by using the following procedure For details refer to the instruction manual supplied with the connector kit Important The N8117 01A expansion RS 232C connector kit contains two types of cables This server uses the RS 232C cable B Tips N8117 01A extra RS 232C connector kit is only supported by air cooled models lt cannot be installed in water cooled models The component parts for N8117 01A are as follows RS 232C connector kit 856 125671 002 a lt gt RS 232C cable RS 232C cable A 804 063264 020 063264 020 PCI bracket 1 243 112122 001 Preinstalled to cable PCI bracket 2 243 112122 002 For full height PCI This product uses a combination of items 3 and 4 Follow the procedure below to install the kit 1 Referto Chapter 2 1 3 Overview of Installation and Removal for preparations Remove the side cover while referring to Chapter 2 1 4 Removing the Side Cover Assemble 3 RS 232C cable B and 4 PCI bracket 1 Aa V N Open the PCI slot retention while referring to Chapter 2 1 10 3 Installation Express5800 GT110d S User s Guide 87 Chapter 2 Preparations 1 Installing Internal Optional Devices 5 Remove the expansion slot cover aligned with the slot where you are going to install a card Important
37. 34 5 Removing the Front Bezel niter s tet ean ena LE Mu Som e EU UR Pav cd 4 6 Internal Flash Memory oooocccccccncocononoconononononononnncnnnnnn conc ee ee nn anne nn n nn nn nn nn nnne nn nn sisi enhn tennis isse sn sn nnns sins nnne 1 6 1 lclEu 1 6 2 REMOVAl eens CMM 1 7 1 Maximum supported memory size ssessseeeeeeeeene emnes 1 7 2 Installation Order ooo 1 7 3 lacune a 1 7 4 Removals oem ER HEIDE S 4 6 Use of Internal Hard Disk Drives in the RAID System sssesseeeee eee 1 8 1 Notes on setting up a RAID System sesssssssseeeeene emm nennen emnes 4 9 Extra Battery for RAID Controler i inr eiaa iaaa 1 9 1 Handling precautions ertt rd Pri EEERER 1 9 2 Installing N8103 121 extra battery ssssssseseeeemm eene 1 9 3 Installing N8103 141 extra battery essen emere 1 9 4 Mo MM Express5800 GT110d S User s Guide Contents Contents TAO PO Caducada testo nal pebenna et echatt E ghaceg ci E TE 78 140 1 NO GOS oie euo ee ae ene bte cies 79 1 10 2 List of option devices and installation slots sesse 80 140 3 Install bas 84 1 10 4 Configuration after InstalliNO se
38. Chapter 2 Preparations 1 Installing Internal Optional Devices 1 135 Connecting cables This section shows an example of internal device cable connection 1 15 1 Interface cables This section describes the connection of interface cables Tips The figure shown here primarily describes connections For more information about the connectors on the motherboard refer to Chapter 1 5 4 Motherboard 1 Connecting Hard Disk Drives This section describes how to connect additional Hard Disk Drives a For 3 5 inch Hard Disk Drive models When adding Hard Disk Drives connect the cables as in the following figure Install the Hard Disk Drives in order from the bottom Connect the first Hard Disk Drive to SATAO the second to SATA1 a Second Hard Disk Drive Motherboard Optical disk drive a First Hard Disk Drive ex SATA cable for even numbered ports WENN SATA cable for odd numbered ports Note To connect the SATA cable connect the right angle connector to the motherboard side and the straight connector to the Hard Disk Drive side You can use the controller on the motherboard to build a RAID System For more information on the RAID level you can build and then method for building RAID Systems see Chapter 2 4 RAID System Configuration in Maintenance Guide 104 Express5800 GT110d S User s Guide Chapter 2 Preparations 1 Installing Internal Optional Devices e Ifa RAID Con
39. D indicates the server status It lights green when the server is operating normally and lights or flashes amber when errors occur Front USB connectors These connectors are used to connect devices that support the USB interface Front bezel This cover protects the front part of the server 3 4 Names and Functions of Parts A ZEN y 9 10 11 UL AN Ml 8 Stabilizer To mount the server vertically install as shown in the image 9 Release tabs 3 at side of front bezel Tabs to unlock the front bezel Pull up to disengage the front bezel 10 Optical disk drive Reads data from or writes data to the disk The drive provides the following an eject button to eject the tray an LED that indicates Hard Disk Drive access and an eject hole for forcibly ejecting the tray 11 3 5 inch device bay The bay which can accommodate 3 5 inch device or extra HDD cage 12 Security key Locks the door of 2 5 inch Hard Disk Drive bays 13 2 5 inch Hard Disk Drive bay door Open this door to handle 2 5 inch Hard Disk Drives This door can be locked with the security key Express5800 GT110d S User s Guide Chapter 1 General Description 4 Names and Functions of Parts 4 2 Rear view 3 5 inch Hard Disk Drive model and 2 5 inch Hard Disk Drive model 5 4
40. Devices Removal of this document remove all Hard Disk Drives installed in the 2 5 inch HDD cage for additional drives 4 Referring to Chapter 2 1 12 1 Installing an expansion 2 5 inch HDD cage remove the HDD cage by reversing the installation procedure 5 If using the server with the HDD cage removed attach the blank panel you have put aside Express5800 GT110d S User s Guide 99 Chapter 2 Preparations 1 Installing Internal Optional Devices 1 1 3 Optical Disk Drive Procedures for replacing the standard optical disk drive with the optional internal DVD SuperMULTI drive are described below Important Do not install a drive other than those specified by NEC 1 13 1 Replacing drives Follow the procedure below to replace your drive with the optional internal DVD SuperMULTI drive 1 Referto Chapter 2 1 3 Overview of Installation and Removal for preparations 2 Remove the side cover and front bezel while referring to Chapter 2 1 4 Removing the Side Cover and 1 5 Removing the Front Bezel 3 While pressing the latch of the SATA cable disconnect the SATA cable from the optical disk drive 4 While pressing the stopper which is situated on the left when you look at from the rear remove the optical disk drive from the server 5 Remove the optical disk drive from the dedicated bracket 6 Install the DVDSuperMULTI drive to the bracket for optical disk drive from which you removed the optical disk drive in
41. Express5800 NEC mi Mui MMM U A NEC Express Server Express5800 Series Express5800 GT110d S GT110d S 2C i3 2120 EXP281A User s Guide Model Number N8100 1739F 1740F 1741F 1742F Chapter 1 General Description Chapter 2 Preparations Chapter 3 Setup Chapter 4 Appendix 10 020 01 101 02 August 2011 Second Edition NEC Corporation 2011 Documents Provided with This Product Documents Provided with This Product Documents for this product are provided as accompanying booklets and as electronic manuals z stored within the EXPRESSBUILDER DVD 2 Precautions for Use Describes points of caution to ensure the safe use of this server Read these cautions before using this server Getting Started Describes how to use this server from unpacking to operations Refer to this guide as you begin for an overview of this server EXPRESSBUILDER User s Guide Chapter 1 General Description Overviews names and functions of the server s parts Chapter 2 Preparations Installation of additional options connection of peripheral devices and ideal location for this server System BIOS configurations and summary of EXPRESSBUILDER Chapter 3 Setting Up Your Server Chapter 4 Appendix Installation Guide Windows Chapter 1 Installing Windows Specifications and other information Installation of Windows and drivers and important information
42. Notations in this document Official names of Windows Windows Server 2008 R2 Windows Server 2008 R2 Standard Windows Server 2008 R2 Enterprise Windows Server 2008 R2 Foundation Windows Server 2008 Windows Server 2008 Standard Windows Server 2008 Enterprise Windows Server 2003 R2 x64 Edition Windows Server 2003 R2 Standard x64 Edition Windows Server 2003 R2 Enterprise x64 Edition Windows Server 2003 R2 Windows Server 2003 R2 Standard Edition Windows Server 2003 R2 Enterprise Edition Windows Server 2003 Windows Server 2003 Standard Edition Windows Server 2003 Enterprise Edition Windows PE Windows Preinstallation Environment 4 Includes 64 bit and 32 bit Editions unless otherwise stated The following appears on EXPRESSBUILDER screen e Windows Server 2008 64 bit Edition Windows Server 2008 x64 e Windows Server 2008 32 bit Edition Windows Server 2008 x32 2 Unless otherwise stated Windows Server 2003 R2 and Windows Server 2003 are collectively referred to as Windows Server 2003 Supported Operating Systems differ depending on the model of this product For details see the following table Editions or Families of Windows GT110d S Windows Server 2008 R2 Standard Windows Server 2008 R2 Enterprise Windows Server 2008 R2 Foundation Windows Server 2008 Standard Windows Server 2008 Enterprise Windows Server 2003 R2 Standard x64 Edition Windows Server 2003 R2 Enterprise x64 Edition Windows Server 2
43. RO Manager 30 Express5800 GT110d S User s Guide Chapter 1 General Description 4 Names and Functions of Parts 4 Names and Functions of Parts Names and functions of parts are as follows A Y Front of the server 1 2 3 4 5 6 3 5 inch Hard Disk Drive model 1 2 3 4 Hu E 6 gt m 3 8 ai Air duct To take air to cool the server POWER switch The switch to turn the server on and off Press once to turn on the server The LED lights green when it is on Press it again to turn off the server Hold down the switch for 4 seconds or more to forcibly turn off the server Power LED green This LED lights green when the power is ON Disk access LED green amber This LED lights or flashes green when the internal Hard Disk Drive is being accessed Status LED green amber This LED indicates the server status It lights green when the server is operating normally Front USB connectors These connectors are used to connect devices that support the USB interface Front bezel removed Off Led 9 10 o 11 7 Front bezel This cover protects the front part of the server Remove this to handle 3 5 inch device and Hard Di
44. RTI Ite hp oie HARES CEG L CUS T FIVEAL TRE Disconnect all AC power cords from both system and external peripherals prior to installing removing options KY SAAB CAI HATRET M Do not drop any screws inside the system aru E FR FRU1773 VBR ORRORG J31 9 274 FESRU ELCBLITED A So BETAXOBRCEUET Refer to the User s Guide when option boards or peripherals are installed Incorrect installations may result in damage to the system and lead to accidents EROS ESO SBORME LOD HTHOLITFSU Firmly hold the bottom of the system when required to lift and carry the system Bm CS ILK AYAPHWET THICBA THORNE IICUTR SU AS some components may become very hot during system operation give A ample time to allow cooling as well as use precaution when handling internal components immediately after powering down BRED 2 CON ITY TRE LIVIANA Some internal components may still be operational on battery power REETSEAICBADILK KAY LOM RV RAS et HA FA Refer to instruction manuals for this system as well as options prior A to maintenance Express5800 GT110d S User s Guide Precautions for Use Be Sure to Read Handling precautions for proper operations Be sure to observe the following precautions for the proper functioning of the server Ignoring the precautions may cause server malfunction or failure e Do not use any cell phone or PHS and switch off them near the server Electric waves from such devices can cause server to m
45. T110d S User s Guide 117 Chapter 2 Preparations 2 Ideal Location and Connection After attaching the stabilizers set up the server as shown in the image b Installing the air duct Tabs on the air duct 4 tabs Orient and insert the 4 tabs into the holes of the server Important 118 Express5800 GT110d S User s Guide Chapter 2 Preparations 2 Ideal Location and Connection 2 For horizontal mounting To mount the server horizontally attach the provided rubber feet to the positions shown in the image Also attach the air duct on the right side of the server the server top if vertically mounted Attach the rubber feet on the right Insert the four tabs in the grooves side of the server as shown in the of the unit image Important 119 Express5800 GT110d S User s Guide Chapter 2 Preparations 2 Ideal Location and Connection 2 2 Connection 120 Connect peripheral devices to the server Connectors that allow a variety of peripheral devices to be connected are provided at the front and rear of the server Images on the following pages show the peripheral devices that can be connected in their standard state and their respective connector positions First connect the peripheral devices and then connect the power cord to the server After that connect the power plug to the outlet A WARNING Be sure to observe the following precautions to use the server safety Failure to observe the pr
46. You can use functional equivalents of AFT SFT ALB teaming with the standard network and the following LAN cards N8104 134 Express5800 GT110d S User s Guide 83 Chapter 2 Preparations 1 Installing Internal Optional Devices 1 10 3 Installation Install a PCI card to connect to a PCI slot by using the following procedure 1 Before installation make sure the switch or jumper settings on the card are properly set according to the instruction manual supplied with the card if necessary 2 Referto Chapter 2 1 3 Overview of Installation and Removal for preparations 3 Remove the side cover while referring to Chapter 2 1 4 Removing the Side Cover 4 Open the PCI slot retention 5 Remove the expansion slot cover aligned with the slot where you are going to install a card Important 84 Express5800 GT110d S User s Guide Chapter 2 Preparations 1 Installing Internal Optional Devices 6 Orient the component side of the card toward the bottom of the server When the rear panel of the card is firmly engaged with the spring firmly press the card into the slot so that the component parts of the card securely connect to the slot The guide of the frame Important 7 Close the PCI slot retention When it locks you hear a clicking sound 8 Assemble the server 9 Turn on the server and confirm that no error messages are displayed in POST If an error message is displayed take notes on the message and ask you
47. a boiler e A place exposed to direct sunlight e An unstable place Do not use the server in an environment where corrosive gas is present Do not install the server in a place subject to corrosive gases including sodium chloride sulfur dioxide hydrogen sulfide nitrogen dioxide chlorine ammonia or ozone Do not install the server in an environment that contains dust chemicals that accelerate corrosion such as NaCl or sulfur or conductive materials Failure to follow this warning may cause the wiring on the printed wiring board to short circuit leading to fire If you have any questions contact the store where you purchased the product or a maintenance service company Do not connect or disconnect any interface cable with the power cord of the server plugged to a power source Be sure to power off the server and unplug the power cord from a power outlet before installing removing any optional internal device or connecting disconnecting any interface cable to from the server If the server is off powered but its power cord is plugged to a power source touching an internal device cable or connector may cause an electric shock or a fire resulted from a short circuit Use only the specified interface cable Use only interface cables provided by NEC and locate a proper device and connector before connecting a cable Using an authorized cable or connecting a cable to an improper destination may cause a short circuit resulting in a fire
48. alfunction e Install the server in an appropriate place For details about the installation location refer to Chapter 2 Preparations 2 Installation and Connection e Before connecting removing cables to from peripheral devices make sure that the server is off and unplug the power cord e Connect the provided power cord to a 100 VAC outlet If an optional cable is used you may connect to a 100 or 200 VAC power system e Make sure that the access LED on the server is off before turning off the power or ejecting an optical disk e Wait for at least 30 seconds before turning on the server after turning off the server If any Uninterruptible Power Supply unit is connected set it to wait for at least 30 seconds before turning on the server after power off e Turn off the server and unplug the power cord before moving it e Regularly clean the server to prevent various types of failure Refer to Chapter 1 Maintenance 2 Daily Maintenance in Maintenance Guide for details about cleaning e Momentary voltage drop may occur due to lightning strike To prevent this use of UPS is recommended e We do not guarantee that any copy protected CD that does not conform to standards will play on the CD player e Make sure that optional devices you are going to install are supported for use with the server Even if they are successfully installed or connected installation of unsupported devices can cause the server to malfunction or even fai
49. ance X4lane X4lane X16lane Product 33 MHz Model name Remarks X8 x8 X16 PCI card type socket socket socket Available card size Up to167 6 mm MD2 N8103 107 SCSI controller Maximum 2 Card performance PCI EXPRESS x1 Connects to internal and external devices Cannot mix with N8103 75 N8103 128 RAID Controller 128 MB RAID 0 1 5 6 Card performance PCI EXPRESS 2 0 x8 N8103 134 RAID Controller 512 MB RAID 0 1 5 6 Card performance PCI EXPRESS 2 0 x8 N8103 129 RAID Controller 256 MB RAID 0 1 Connects with internal drives Card performance PCI EXPRESS 2 0 x8 Can mount internal battery N8103 121 N8103 130 RAID Controller 256 MB RAID 0 1 5 6 Card performance PCI EXPRESS 2 0 x8 N8104 134 1000BASE T connection board 2 ch For adding LAN Card performance PCI EXPRESS x4 Teaming AFT SFT ALB and bonding with N8104 134 and on board LAN is supported Up to 2 teams per system Up to 2 ports per team N8117 01A Additional RS 232C connector kit 2 lol ol o l For additional serial RS 232C port O Can be installed Cannot be installed 1 Lane Indicates the transfer performance transfer bandwidth e g 1 lane 2 5 Gbps unidirectional 4 lanes 10 Gbps unidirectional Socket Indicates the connector size A card up to the number of sockets can be connected e g x4socket x1card x4card can be installed x8 card cannot be installed 2 The N8117 01A expansion RS 232C
50. at both the top and bottom of the side cover are securely inserted in the holes on the server frame Also make sure that the hooks at the front of the cover are engaged with the server frame when sliding the side cover forward to attach If they are not engaged with the frame the cover cannot be secured in place Hooks at the top of the server Insertion holes for the hooks The hooks at the front of the server a J a a a m DS ls Hooks at the bottom of the server Insertion holes for the hooks Rear view of side cover Plate for the Frame of the server chassis lock 114 Express5800 GT110d S User s Guide Chapter 2 Preparations 2 Ideal Location and Connection 2 Ideal Location and Connection This section describes how to position the server and connect cables 2 4 Ideal location for the server CAUTION Be sure to observe the following precautions to use of the server safely Failure to observe the precautions may cause burns injury and property damage For details refer to Safety precautions in Precautions for Use Do not attempt to lift the server by gripping the front bezel or air duct e Install and store only in the specified environment The environment suitable for the server is as follows Hold the server firmly and slowly and gently place it in the position in which it is to be insta
51. ations 1 Installing Internal Optional Devices 4 Engage the tabs of the bracket with the grille of the blank cover and fix it with the attached screw large Refer to the image below for the installation position Installation position Engage the tab with the part second from left at the bottom 74 Express5800 GT110d S User s Guide Chapter 2 Preparations 1 Installing Internal Optional Devices 5 Engage the tabs at the lower part of the blank cover with the chassis and fix it with the two screws If the cable is too long arrange it neatly such as by coiling it once within the chassis Pass through the remote cable equipped with the battery from inside to outside the unit This concludes the installation of the battery module in a 2 5 inch Hard Disk Drive model Express5800 GT110d S User s Guide 75 Chapter 2 Preparations 1 Installing Internal Optional Devices Installing a battery pack to 3 5 inch Hard Disk Drive models 1 Remove one screw from the blank cover and slide it to the side to release the blank cover 2 Pass the bracket containing the battery and which is connected to the remote cable through the opening from which the blank cover was removed Pass through the remote cable equipped with the battery from inside to outside the unit 3 Engage the tabs of the bracket with the grille of
52. close of the covers and doors on the chassis Software Shows service driver and OS information Shows BIOS information Monitors the values of an MIB item obtained by NEC ESMPRO Agent Monitors controllers and storage devices including Hard Disk Drives Shows the file system configuration and monitors the free space Monitors the following RAID Controllers BIOS Local polling Storage File system RAID System Disk Array e On board RAID Controller LSI Embedded MegaRAID e Optional RAID Controller N8103 128 129 130 134 Monitors OS stall using the Watch Dog Timer Performs alert processing after an OS STOP error occurs Others Network lo Shows network LAN information and monitors packets O Supported A Partially supported x Unsupported Not displayed on the NEC ESMPRO Manager screen Tips NEC ESMPRO Manager and NEC ESMPRO Agent are supplied with the server as standard For how to install and use each software component refer to the explanation of the component Express5800 GT110d S User s Guide 29 Chapter 1 General Description 3 Standard Features 3 2 Firmware and Software Version Management By using NEC ESMPRO Manager and ExpressUpdate Agent you can manage firmware or software on the server and update them by applying an update package This function automatically updates multiple modules without stopping the system just by specifying the application of an update package from NEC ESMP
53. connector kit contains two types of cables This server uses the RS 232C cable B e The depth of mountable boards is up to 167 6 mm MD2 e For details of functions of each card refer to the technical guide e The card performance described in the parentheses after the Product name indicates the maximum operation performance of the card e Even if you use PCI cards of a higher performance than the PCI slot the operation of the device will be that of the PCI slot About the standard network You can use functional equivalents of AFT SFT ALB teaming with the standard network and the following LAN cards N8104 134 80 Express5800 GT110d S User s Guide Chapter 2 Preparations 1 Installing Internal Optional Devices 3 5 inch Hard Disk Drive model water cooling system PCI EXPRESS 2 0 PCI 1 PCI 2 Product Sese size Low Profile PCI card type socket socket Available card size card size Up to167 6 mm MD2 N8103 107 SCSI controlle Connects to internal and external devices Card performance PCI EXPRESS x1 N8103 128 RAID Controller 128 MB RAID 0 1 5 6 Connects with internal drives Card performance PCI EXPRESS 2 0 x8 Can mount internal battery N8103 141 450 N8103 134 RAID Controller 512 MB RAID 0 1 5 6 mm cable Card performance PCI EXPRESS 2 0 x8 N8103 129 RAID Controller 256 MB RAID 0 1 Connects with internal drives made by LSI Card performance PCI EXPRESS 2 0 x8 Technology N8103 130
54. ctory settings About 3 3 GB If not using HW DEP function Note If you are not using the HW DEP function set the Execute Disable Bit XD Bit to Disable in the BIOS setup It is enabled by default Windows Server 2008 R2 Foundation Windows Server 2003 R2 Standard x64 Edition Windows Server 2008 Standard x64 Edition Windows Server 2008 R2 Standard Windows Server 2008 R2 Enterprise 1 7 2 Installation order Install DIMMs one by one in order of increasing memory size into slots in the order of DIMM 1 DIMM 2 DIMM 3 and DIMM 4 However if you want to run the server in Dual Channel mode observe the following when installing the DIMMs e Install them in pairs e The two memories installed together must be of the same specifications and memory size e Install the pairs as DIMM 1 and DIMM 2 or DIMM 3 and DIMMZA the installation order between the pairs does not matter Installation examples Dual Channel Example DIMM 1 DIMM 2 DIMM 3 DIMM 4 Memory mode Runs 2 GB DIMM 2 GB DIMM Not installed Not installed Standard 2 Runs 2 GB DIMM 2 GB DIMM 2 GB DIMM 2 GB DIMM Standard 3 Does not run 2 GB DIMM 2 GB DIMM 2 GB DIMM Not installed Standard 4 Does not run 2 GB DIMM 2 GB DIMM Not installed 2GB DIMM Standard Express5800 GT110d S User s Guide 51 Chapter 2 Preparations 1 Installing Internal Optional Devices 1 7 3 52 Installation Install a DIMM by using the following procedure Refer to steps
55. d Disk Drives Installed on 2 5 inch model as standard a When using on board RAID Controllers LSI Embedded MegaRAID By changing the jumper setting for RAID configuration on the motherboard the internal Hard Disk Drive can be recognized as a software controlled RAID System Hard Disk Drive Jumper settings on the motherboard and backplane Change the jumper pin settings as described below Jumper pins on motherboard SWRAID Enabled 2 3 Disabled 1 2 Default value Backplane for 2 5 inch Hard Disk Drive provided with 2 5 inch models J7 A E eccooocooocoooo occooocooo sen pri e vio PAG o On board SATA controller Express5800 GT110d S User s Guide 55 Chapter 2 Preparations b 56 1 Installing Internal Optional Devices After that configure the RAID System using LSI Software RAID Configuration Utility For details refer to Chapter 2 4 RAID System Configuration in Maintenance Guide If you use the EXPRESSBUILDER DVD supplied with the server for setup the RAID System is automatically configured Or you intend to install Windows OS OS also can be installed automatically and seamlessly Tips If an optional RAID Controller N8103 128 129 130 134 is used If using internal Hard Disk Drives in a RAID System with an optional RAID Controller N8103 128 129 130 134 installed in the server the followin
56. e Hard Disk Drive all the way into the HDD cage After the insertion close the lever to fix the Hard Disk Drive into place It is locked when you hear a clicking sound Important Note 3 Securely hold the tray and handle and attach it to the HDD cage so that it is straight Important 4 Close the 2 5 inch Hard Disk Drive bay and lock with the security key Express5800 GT110d S User s Guide 97 Chapter 2 Preparations 1 Installing Internal Optional Devices 1 12 5 Removal 1 12 4 98 You can remove the Hard Disk Drive by using the following procedure Important 1 Refer to Chapter 2 1 3 Overview of Installation and Removal for preparations 2 Unlock the security key and open the door of the 2 5 inch Hard Disk Drive bay 3 Remove the Hard Disk Drive while referring to steps 2 in Chapter 2 0 Installation 5 Close the 2 5 inch Hard Disk Drive bay and lock with the security key A Removing the 2 5 inch HDD cage for additional drives You can remove the 2 5 inch HDD cage for additional drives by using the following procedure 1 Referto Chapter 2 1 3 Overview of Installation and Removal for preparations 2 Remove the side cover and front bezel while referring to Chapter 2 1 4 Removing the Side Cover and 1 5 Removing the Front Bezel 3 Referring to Chapter 2 1 12 3 Express5800 GT110d S User s Guide Chapter 2 Preparations 1 Installing Internal Optional
57. e as an option e BIOS password feature Management utilities e NEC ESMPRO e ExpressUpdate e Remote controlling featuer EXPRESSSCOPE Engine 3 e RAID System management utility Universal RAID Utility e Hard Disk Drive monitoring Power saving and noiseless design e Power monitoring feature e Power control feature e High efficiency power supply supporting 80 PLUS Silver e Fan control appropriate to environment work load and configuration e Enhanced Intel SpeedStep Technology supported Expandability e Many lO option slots PCI Express 2 0 x 16 lanes 1 slot PCI Express 2 0 x 4 lanes 2 slots PCI 32 bits 33 MHz 1 slot For water cooled models 1 slot of PCI Express 2 0 4 lanes and PCI 32 bits 33 MHz slot cannot be used Large memory of up to 32 GB Backup device bay provided as standard USB2 0 interface Three LAN ports one for management LAN Ready to use e Hard Disk Drives can be installed with one touch setup which requires no cables hot swap supported Express5800 GT110d S User s Guide 27 Chapter 1 General Description 3 Standard Features Many built in features e El Torito Bootable CD ROM no emulation mode format supported e Software power off e Remote power on feature e AC Link feature e Remote console feature e Baseboard Management Controller BMC conforming to IPMI v2 0 Self diagnosis e Power On Self Test POST e Test and Diagnosis T amp D utility Easy setup
58. e installation procedure If you intend to use with the card removed be sure to attach the slot cover attached to the riser card The slot cover must be screwed into place 1 8 1 Notes on setting up a RAID System Note the following points when setting up a RAID System e The number of Hard Disk Drives required varies in each RAID level e Ifan on board RAID Controller or optional RAID Controller N8103 128 129 is used the RAID System cannot be built in RAID5 RAID6 The minimum number of Hard Disk Drives required to set up a RAID System RAID level On board RAID Controller or N8103 128 129 N8103 130 134 1 1 2 e Use SAS SATA Hard Disk Drives or SSDs that have the same capacity and rotational speed e As the size of Logical Drive cannot be specified in RAID 10 with the on board RAID Controller the Logical Drive size will be at least 4 TB if a Hard Disk Drive of 2 TB or more is used However the Logical Drive where the OS is to be installed may be up to 2 TB due to OS restrictions and therefore RAID 10 using a Hard Disk Drive of 2 TB or more cannot be supported if an on board RAID Controller is used When installing an OS in your RAID System you can easily complete the setup process including RAID configuration and OS installation by using EXPRESSBUILDER If you are installing the OS manually use the RAID System configuration utility The utility can be run during POST which starts immediately after the server is turned on For deta
59. e rear of the RAID Controller 303 ala QM rorem we vq on e Mete o 62 Express5800 GT110d S User s Guide Chapter 2 Preparations 1 Installing Internal Optional Devices Installing a battery pack to 2 5 inch Hard Disk Drive models 1 Remove the file device or blank panel For the blank panel pull it toward you while pressing the tab on the right 2 Remove the two screws from the blank cover Express5800 GT110d S User s Guide 63 Chapter 2 Preparations 1 Installing Internal Optional Devices 3 Engage the tabs of the bracket with the grille of the blank cover and fix it with the attached screw large Refer to the image below for the installation position Installation position Engage the tab with the part second from left at the bottom 64 Express5800 GT110d S User s Guide Chapter 2 Preparations 1 Installing Internal Optional Devices 4 Engage the tabs at the lower part of the blank cover with the chassis and fix it with the two screws If the cable is too long arrange it neatly such as by coiling it once within the chassis Express5800 GT110d S User s Guide 65 Chapter 2 Preparations 1 Installing Internal Optional Devices Installing a battery pack to 3 5 inch Hard Disk Drive models 1 Remove one screw from the blank cover and slide it to the side to release the blank cover
60. e the battery by yourself 44 CAUTION High temperature Components including internal Hard Disk Drives in the server are extremely hot just after the server is turned off Allow the surface to cool before installing removing Secure cables or cards in place Be sure to secure the power cord interface cables and cards in place Incomplete installation causes a loose connection resulting in smoke or fire 18 Express5800 GT110d S User s Guide Precautions for Use Be Sure to Read During operation CAUTION Avoid contact with the server during thunderstorms Do not touch any part of the server including the cables when a thunderstorm is approaching Also do not connect or disconnect any devices There may be a risk of electric shock from lightning strike Keep animals away from the server Keep animals such as pets away from the server Pet hair or other waste enters the server which may cause a fire or electric shock Do not place any object on top of vertically mounted servers Any weight on the server may cause the server to fall resulting in personal injury or property damage Do not place any object that weighs 5 kg or more on top of horizontally mounted servers The maximum weight that can be placed on top of the server when it is horizontally mounted is 5 kg Do not place any object weighing 5 kg or more on top of the server Failure to observe this limit may deform the server which could cause a failure
61. ecautions may cause death or serious injury For details refer to Safety precautions in Precautions for Use e Do not hold the power plug with wet hands CAUTION Be sure to observe the following precautions to use of the server safely Failure to observe the precautions may cause burns injury and property damage For details refer to Safety precautions in Precautions for Use Use only the specified outlet to insert Do not connect the power cord to an outlet that has an illegal number of connections Insert the power plug into the outlet as far as it goes Use only the specified power cord Do not connect or disconnect the interface cable while the power cord is connected Use only the specified interface cable Express5800 GT110d S User s Guide Chapter 2 Preparations 2 Ideal Location and Connection 2 2 1 Interface cables First connect the interface cable and then the power cord Important Express5800 GT110d S User s Guide 121 Chapter 2 Preparations 2 Ideal Location and Connection Front view ZE EFO USB devices such as a FD drive lt Rear view gt A device with serial Finally connect the interface provided power cord to such as a modem an outlet lt gt a Display unit lsssssssall BEB8BB8B888 o IDBDBDBDDDDD o lt gt Hub Switching hub USB devices such as a terminal adapter 122 Exp
62. ector 1 Serial ATA connector 0 9 Serial ATA A connector 1 088 e EE caes E re 2 Refer to Chapter 2 1 3 Overview of Installation and Removal for preparations 3 Remove the side cover and front bezel while referring to Chapter 2 1 4 Removing the Side Cover and 1 5 Removing the Front Bezel 4 Disconnect the optical disk drive cable 5 While pressing the stopper on the left remove the optical disk drive Express5800 GT110d S User s Guide 91 Chapter 2 Preparations 1 Installing Internal Optional Devices 6 Ifthe 3 5 inch device is attached remove the cable and then remove the device For details refer to Chapter 2 1 14 Backup devices 7T Liftthe rear part of the sub frame to remove the sub frame 8 Remove the two screws and remove the 3 5 inch Hard Disk Drive tray If you intend to install two Hard Disk Drives repeat the following procedure for the second unit 9 Attach the Hard Disk Drive tray to the Hard Disk Drive with the provided four screws screw set 505 Important 10 Install the Hard Disk Drive in the server and connect the interface cable and power cable Then fix it with the designated two screws Note 11 Assemble the server
63. ed company An uncorrectable error in memory is detected A PCI system error occurred A PCI parity error occurred A PCI bus error occurred Memory dump is being requested Wait until the memory dump is completed e g when DUMP switch NMI is pressed Note t remains green if the dump is caused by software On amber A temperature alarm was detected Check the internal fan for dusts Also check if the fan unit is properly connected If the LED indication does not change when the fans are normal contact your maintenance service company A voltage alarm was detected Contact your maintenance service company A CPU temperature alarm was detected SMI timeout is detected 40 Express5800 GT110d S User s Guide Chapter 1 General Description 4 Names and Functions of Parts Status LED pater Explanation Flashing amber Failure of the power supply unit is detected Connect the power cord to supply power If the power supply unit is faulty contact your maintenance service company A fan alarm was detected Check if the internal fan cable is properly connected If the LED indication does not change when the fans are normal contact your maintenance service company A temperature warning was detected Check the internal fan for dusts Also check if the fan unit is properly connected If the LED indication does not change when the fans are normal contact your maintenance service company A voltage warning
64. eeeaeaeeeeeeeeeaaeaeceseeeseceaeaeaeeeeeeeesegeaeaeeeseseseeaeeeeeeegs 29 3 2 Firmware and Software Version Management ssssssssseeee enm eene errem 30 Express5800 GT110d S User s Guide 3 4 Names and Functions of Parls ici ii A rar tii AoE Ont OMG I II LS LU LLLI TES GE CC E E sazecsteehendaagaesess 43 O C 4 4 Motherboard e z E Status MCI GALTON sce cis tae ce uu 3 E ora he cece agence ee eect 332 a 4 5 3 Disk access LED il p e 4 5 4 Optical disk access LED crror rinrin tena rit Fano tenete t ia 45 5 DISK TED AP Net e poe ie he eesieuk EE LINK ACT LED mE E52 mas ciere tea etia ce a e Oe 45 7 SpeedLED BE Ere REM caccccccccecocsccsscccsussasasussacsccaccdacovsechesccgussasususdeceeceecdaseceechenstete Chapter 2 uirorum I Installing Internal Optional Devices necne testaminten ein usua tab Deui resa inner end Ti Safety Precautions sreske ER 1 2 Anti static Measures sssssssssseeeenennneeene nennen nennen nennen nennen nennen en renr nennen enne enne enne 4 3 Overview of Installation and Remowval sse eene eene nen nennen nene 4 4 Removing the Side Cover ices ss itii de ite hai ia ia adea e pae neue sa B Ogg eodera ua rupe
65. enne enm 116 B Connection 5 i e Ne Genes as 119 2 2 1 Interface cables aer 120 2 2 2 Power COMM vanced aie RH eec a S 122 Express5800 GT110d S User s Guide 5 Contents Chapter Setup na NR 123 I TUMIND ON the DONE ini 124 EL POST 125 1 1 1 POST Sequeri66 cuin eee e Iud tese Mesum tet dee a 125 1 1 2 POST Error Messages innere re ibi 127 2 System BIOS Setups E 128 PNAEMPBO SI EE 128 2 2 Starting SETUP Utllity di ias 128 2 3 Description on On Screen Items and Key Usage sss eee 129 2 4 Cases that Require Configuration nennen nennen nene enne 131 3 EXPRESSSCOPE ENGINE 3 tt eei Ent eoe PE Pe ee Ed RA TU que AEn eun dela Ee ed e INR E aR 133 SH MEO ISSN 133 3 2 EXPRESSSCOPE ENGINE 3 Network configuration see 133 4 EXPRESSBUILDER uet te et rr mu e E Ea aede 135 4 1 Features of EXPRESSBUILDER rne ipee Hee Ene e e ete e Eee o EE ee EE de ne uet 135 4 2 Starting EXPRESSBUILDER iie ieri ED co doen Ed ce ve tee deae Icd opine 135 J Installing Software Components sssssssssseenene eene een nee enhn enne nennen enn rennen nennen 136 6 Tutnirig Off the Server issnin e Le I UI eee tetigere send cud bene 137 Chapter 4 Appa dr 138 To SPSCiHICAUONS pia EE 139 LT AIECOOLNO System ica set 139 1 2 Watercooling System xenon vU 140 2 Interrupt Li
66. er Turn on the server by using the following procedure 1 Disconnect Flash FDD if applicable 2 Turn on the peripheral devices that connect to the display monitor and the server Note 3 Press the POWER switch at the front of the server The POWER LED is turned on green and after a while the NEC logo appears on the display While the NEC logo is being displayed the self diagnostic program POST runs and diagnoses the hardware For details refer to Chapter 3 1 1 POST Express5800 GT110d S User s Guide 125 Chapter 3 Setup 1 Turning on the Server 1 I POST POST Power On Self Test is a self diagnostic program stored in the server as standard POST automatically runs immediately after the server is turned on and checks the motherboard memory processor CPU keyboard and mouse POST also displays the start up messages of different utilities during the operation Usually you do not need to check the contents of POST However check messages displayed at POST in the following cases e When introducing a server e f you suspect a failure e When you hear beep many times during the time between Power ON and OS startup e When any error message is displayed 1 1 1 POST sequence Explains how POST runs in order Important 1 When the server is turned on POST runs POST starts memory check When the memory check is completed some messages appear As factory settings the NEC logo appea
67. er s Guide 81 Chapter 2 Preparations 1 Installing Internal Optional Devices 2 5 inch Hard Disk Drive model air cooling system PCI EXPRESS 2 0 PCI 1 PCI 2 PCIZ3 PCI 4 F 32 bit PCI slot performance X4lane X4lane X16lane Product 33 MHz Model name Remarks namg Slot size Low Profile X8 x8 X16 PCI card type 5V socket socket socket Available card size Up to 167 6 mm MD N8103 107 SCSI controller Card performance PCI EXPRESS x1 N8103 128 RAID Controller 128 MB RAID 0 1 5 6 Card performance PCI EXPRESS 2 0 x8 N8103 134 RAID Controller 512 MB RAID 0 1 5 6 Card performance PCI EXPRESS 2 0 x8 N8103 129 RAID Controller 256 MB RAID 0 1 Connects with internal drives made by LSI Card performance PCI EXPRESS 2 0 x8 Technology N8103 130 RAID Controller 256 MB RAID 0 1 5 6 Can mount internal battery N8103 121 Card performance PCI EXPRESS 2 0 x8 N8104 134 1000BASE T connection board 2 ch For adding LAN Card performance PCI EXPRESS x4 Teaming AFT SFT ALB and bonding with N8104 134 and on board LAN is supported Up to 2 teams per system Up to 2 ports per team N8117 01A Additional RS 232C connector kit 2 os las corr Hare For additional serial RS 232C port O Can be installed Cannot be installed 1 Lane Indicates the transfer performance transfer bandwidth e g 1 lane 2 5 Gbps unidirectional 4 lanes 10 Gbps unidirectional Socket Indicates
68. es and other countries All other product brand or trade names used in this publication are the trademarks or registered trademarks of their respective trademark owners Express5800 GT110d S User s Guide 9 Regulatory Notices Regulatory Notices FCC Statement This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense CE Statement This is a Class A product In domestic environment this product may cause radio interference in which case the user may be required to take adequate measures EN55022 BSMI Statement re EIS E PAE ERER Ap ER WR ARE SKATE gt fos v F HAS ARERR HA MMAR o 10 Express5800 GT110d S User s Guide Warnings and Additions to This Document Warnings and Additions to This Document 1 Unauthorized reproduction of the contents of this document in part or in its entirety is prohibited 2 The conten
69. for installation Installation of bundled software such as ESMPRO and Universal RAID Utility Chapter 2 Installing the Bundled Software Maintenance Guide Chapter 1 Maintenance Server maintenance and troubleshooting Chapter 2 Convenient Features Useful features and the detail of system BIOS settings RAID Configuration Utility and EXPRESSBUILDER Error messages and Windows Event Logs Chapter 3 Appendix Other documents Provides the detail of ESMPRO Universal RAID Utility and the other features 2 Express5800 GT110d S User s Guide Contents Contents Documents Provided with This ProdUCt oooooococcccccccocococccnccncconanononnnnncnnnnnn no nn cnnnnnnnnn nn nn rnnn nana deiei daidi nr n nnns ns nnne nnns 2 gna fme a A AA ad 3 Notations Used in This DocUMeNt cccccncococcccccccnnconononcconcnnnnnnnnncnn cnn acne nn narran enn enn nn cana aa nere nn nan r sinn aieiaiei sns eiat nnns 7 Notations used in the text idas inci 7 Optical disk dives uis dla ia 7 Hard Disk A O E 7 Removable AAPP OO 7 Abbreviations of Operating Systems oooonocccnnoccccnononcncnononcnnn nono nonn non n nr nano nennen ene rr rre rn enter nennen enne 8 Trademarks cursado cult ska s exa aed rc lo dei edo cas leas 9 Regulatory Notic sS coi cornisas 10 Warnings and Additions to This DOCUMENt oocococccccccccnconononocononananonononnnnnnnnnnnn nennen ethernet sr nn anne annn nn nr nr nnen nnne
70. g cable is required instead of using the interface cable supplied with the server For 3 5 inch Hard Disk Drives K410 253 00 internal SAS SATA cable For 2 5 inch Hard Disk Drives K410 180 00 internal SAS cable Jumper settings on the motherboard and backplane Change the jumper pin settings as described below Jumper pins on motherboard SWRAID Disabled 1 2 Default value Enabled 2 3 Backplane for 2 5 inch Hard Disk Drive provided with 2 5 inch models J7 ZEN Zur Pm went ABN of o blo e e oB 000000060060 3 o wr HEHEH 8666906 sokl sj ES BREH 7 ATK ap O C o LA OR oyo O Mu s ON L o 3 oo DOHHCUQOCLIECORT q S oLz wo cuo Pl 5 g p Js EA Ole mmmn b e A aT Ol q TE Q On board SATA controller N8103 128 129 and N8103 128 129 130 134 are to be connected for 3 5 inch Hard Disk Drive model and for 2 5 inch Hard Disk Drive model respectively Tips Note important Do not change the mode to hibernate when building a RAID System Express5800 GT110d S User s Guide Chapter 2 Preparations 1 Installing Internal Optional Devices c Installation For the instruction of installing the optional RAID Controller N8103 128 129 130 134 refer to Chapter 2 1 10 PCI Cara Important d Removal To remove the optional RAID Controller N8103 128 129 130 134 reverse th
71. has specialized knowledge of this server Use only the devices and cables specified by NEC You will be charged to repair damages malfunctions and failures caused by the use of any devices or cables not specified for use with this server even within the warranty period 4 4 Safety Precautions Be sure to observe the following precautions to install and remove optional devices properly and safely A WARNING Be sure to observe the following precautions to use the server safety Failure to observe the precautions may cause death or serious injury For details refer to Safety precautions in Precautions for Use e Do not disassemble repair or modify the server e Do not remove the lithium NiMH or Li ion battery e Do not handle the server while the power plug is inserted into the outlet 44 CAUTION Be sure to observe the following precautions to use of the server safely Failure to observe the precautions may cause burns injury and property damage For details refer to Safety precautions in Precautions for Use Do not attempt to lift the server by gripping the front bezel or air duct Make sure to complete installation Do not get your fingers caught High temperature 44 Express5800 GT110d S User s Guide Chapter 2 Preparations 1 Installing Internal Optional Devices 1 2 Anti static Measures The server contains electronic components sensitive to static electricity Avoid failures caused by static
72. ils on the procedure of configuring a Logical Drive refer to Chapter 2 4 RAID System Configuration in Maintenance Guide or the manual supplied with the optional RAID Controller N8103 128 129 130 134 Important Express5800 GT110d S User s Guide 57 Chapter 2 Preparations 58 1 Installing Internal Optional Devices e The display of slot numbers SLT for Hard Disk Drives in the OS system event log varies depending on the RAID Controller to be connected The tables below show the insert position of Hard Disk Drives and slot numbers SLT The information on these tables is important when checking logs or replacing a Hard Disk Drive Example Slot numbers SLT for HDD and SSD displayed in OS system event log xi 4i raidsrv 749 Va CTRL 1 10 0 LSI Corporation LSI Embedded MegaRAID LD 1 1D 0 4150 PD 1 2 34 STSI PD 1 10 4SLT 1 NA PD 2011 1 SLT 2 AY PD 3 IIV 2 SLT 3 ATA IPD s ID NSLT 1 fr PD 5 ID 5 SC7 6 1 ATA npe YAS A IDE VAM 23940 ANTRO SEGGIRTROD gei 3AE STSAUS1Y 2AE STEM RAE STSdv2dv ST3280820NS 8E Sio M HL DT STDVD ROM 0P04 ST3250820NS ST3250820NS EM PATh raidsry Dn2o0Bfht 2010 02 04 13 42 19 702 ARAOATAVY aL aR KINO 53795 N A ZJv i 5 R Nicolas 9 AAA DAQAMNZ ALSO Models with 3 5 inch Hard Disk Drives installed Slot numbers indicated Optional RAID Controllers On board RAID Control
73. ing fan for cooling CPU 9 Motherboard 3 DIMM slot 10 Radiator cooling fan front 4 SAS backplane 11 Radiator cooling fan rear 5 2 5 inch Hard Disk Drive 12 Radiator 6 HDD fan 13 PCI slot 7 Optical disk drive 14 Rear fan Express5800 GT110d S User s Guide 37 Chapter 1 General Description 4 Names and Functions of Parts A A Motherboard 3 5 inch Hard Disk Drive model 2 5 inch Hard Disk Drive model aaa EEES Lun 20 Aj O qa e pol 17 16 13 15 11 10 9 14 7 22 23 1 DIMM slots the number after hyphen indicates DIMM 17 SPI Flash Mezzanine connector number EXPRESSSCOPE profile key SPI flash memory has 2 Power connector been installed where BIOS and BMC configuration data is 3 CPU socket stored Move it when replacing MB to keep using the data 4 CPU cooling fan connector 18 PCI card slots 18 1 PCI EXPRESS x4 x8 connector 18 2 PCI EXPRESS x4 x8 connector 18 3 PCI EXPRESS x16 5 RAID LED cable connector 6 Serial ATA connector the number after hyphen indicates connector number 18 4 PCI 32 bits 33 MHz 7 Lithium battery Not available for water cooled models 8 Buzzer 19 Lower DUMP switch NMI 9 CMOS configuration jumper switch Upper BMC RESET M RESET switch 10 RAID switch jumper 20 External connector 11 Password clear jumper 12 SGPIO connect
74. into the outlet Before disconnecting the ground wire be sure to disconnect the power plug from the output Do not connect many cords into a single outlet by using extension cords The electric current exceeding the rated flow overheats the outlet which may cause a fire Do not pull out a cable by gripping the cable part Pull a cable straight out by gripping the connector part Pulling a cable by gripping the cable part or applying extra pressure to the connector part may damage the cable part which may cause a fire or electric shock Insert the power plug into the outlet as far as it goes Heat generation resulting from a halfway inserted power plug imperfect contact may cause a fire Heat will also be generated if condensation is formed on dusty blades of the halfway inserted plug increasing the possibility of fire Express5800 GT110d S User s Guide 15 16 Precautions for Use Be Sure to Read 44 CAUTION Do not use any unauthorized interface cable Use only the interface cables provided with the server Electric current that exceeds the amount allowed could cause fire Also observe the following precautions to prevent electrical shock or fire caused by a damaged power cord Do not stretch the cord harness Do not pinch the power cord Do not bend the power cord Keep chemicals away from the power cord Do not twist the power cord Do not place any object on the power cord Do not step on the power cord Do not alter
75. ion 134 To enable EXPRESSSCOPE Engine 3 to be used via network network configuration is required The following procedure describes how to enable the use of the engine on web browsers 1 Run POST following Chapter 3 1 1 1 POST sequence Wait until the following message appears on the lower left of the screen Press F2 SETUP F3 Internal Flash Memory F4 ROM Utility lt F12 gt Network If you press the F4 key at this time ROM utility starts upon completion of POST You can also press the F4 key while the NEC logo is being displayed to open the Off line TOOL MENU screen The keyboard selection screen appears Select your keyboard type After that the Off line TOOL MENU screen appears On this screen specify the network settings for EXPRESSSCOPE Engine 3 Express5800 GT110d S User s Guide Chapter 3 Setup 3 EXPRESSSCOPE ENGINE 3 4 When the Off line TOOL MENU appears select BMC Configuration BMC Configuration Network and then Property Off line TOOL MENU Off line TOOL MENU Maintenance Utility 5 If Property is selected the following screen is displayed On this screen specify whether to use DHCP and if DHCP is not used configure IP Address Subnet Mask etuork Property omection Type Auto Negotiation BMC MAC Address 00 11 22 AA BB CC DHCP Disable IP Address Required 192 168 0 1 Subnet Mask Required 255 255 255 0 Default Gateway 192 168 0 2 DNS Server
76. isk Drives from Slot 0 in ascending order When 3 Hard Disk Drives are installed Slot 2 Third Hard Disk Drive Slot 1 Second Hard Disk Drive Slot 0 First Hard Disk Drive Motherboard Optical disk drive Extra battery N8103 121 141 RAID Controller N8103 128 129 130 134 mmmmmE internal SATA cable K410 180 00 mmmmmm Battery cable attached to the expansion battery EEEEEN SATA cable for use with the optical disk drive CIC MB SASBP signal cable Express5800 GT110d S User s Guide 107 Chapter 2 Preparations 1 Installing Internal Optional Devices 108 When 5 Hard Disk Drives are installed RAID Controller N8103 128 129 130 134 Soooo0 0000 500000 0000 o Slot 2 Third Hard Disk Drive Slot 1 Second Hard Disk Drive Slot 0 First Hard Disk Drive Motherboard Optical disk drive Extra battery N8103 121 141 2 5 inch expansion HDD cage mmmmmm Internal SATA cable K410 180 00 Hu Battery cable attached to the expansion battery EXE SATA cable for use with the optical disk drive 00000000 0000 00000000 0000 f 00000000 0000 00000000 0000 J cuam MB SASBP signal cable attached to the 2 5 inch expansion HDD cage EZ SATA cable attached to the 2 5 inch expansion HDD cage Slot 5 Fifth Hard Disk Drive Slot 4 Fourth Hard Disk Drive Tips e N8154 37 2 5 inch HDD cage for additional drives cannot be installed
77. lers N8103 128 129 130 134 SLT 1 SLT 1 SLT 2 SLT 2 Models with 2 5 inch Hard Disk Drives installed Slot numbers indicated Optional RAID Controllers On board RAID Controllers N8103 128 129 1 30 134 Insert position numbers displayed on the server Insert position numbers displayed on the server 1 Tips SLT 1 SLT 2 SLT 4 SLT 5 Slot number to install SLT 1 SLT 2 SLT 3 SLT 4 SLT 5 The insert position number displayed on the server starts from 0 SLT of on board optional RAID Controllers displayed starts from 1 Express5800 GT110d S User s Guide Chapter 2 Preparations 1 Installing Internal Optional Devices The insert position number displayed on the server Models with 3 5 inch Hard Disk Drives installed Models with 2 5 inch Hard Disk Drives installed standard HDD cage Models with 2 5 inch Hard Disk Drives installed when expansion 2 5 inch HDD cages are installed Express5800 GT110d S User s Guide 59 Chapter 2 Preparations 1 Installing Internal Optional Devices 1 9 Extra Battery for RAID Controller 60 If a RAID Controller N8103 128 129 130 134 is installed use the optional extra battery to avoid data loss caused by accidents including temporary blackout during a write back operation The model of the extra battery to be used depends on RAID Controller e For N8103 129 130 use N8
78. lled At least 150 mm clearance in front of behind the server Cables for the mouse or other devices are within easy reach The environment that satisfies the following conditions Operating Ambient temperature 10 C to 40 C Humidity 20 to 80 y Temperature gradient 10 C hour f On a flat and Air pressure 749 to 1040 hpa sturdy desk lt Storage gt Ambient temperature 5 C to 40 C Humidity 10 to 80 Temperature gradient 15 C hour Air pressure 749 to 1040 hpa 100 VAC bipolar grounded outlet A Dust free clean and organized room Express5800 GT110d S User s Guide 115 Chapter 2 Preparations 116 2 Ideal Location and Connection Do not install the server in an environment in which any of the following conditions apply Installing the server in any of the following conditions will cause the server to malfunction Place of drastic temperature change near a heater air conditioner or refrigerator Place where a carpet not subject to anti static process is laid Place where the power cord of the server must be connected to an AC outlet that shares the ground wire with another outlet where another device with large power consumption is connected Express5800 GT110d S User s Guide Place where intense vibration may be generated Place where some objects may be fallen Place near a device generating intense magnetic field such as TVs radios broadcast communication ante
79. lure e In the following cases check and adjust the system clock before operation After transportation After storage After the server is used following a period of disuse in which storage conditions did not conform to those that guarantee server operations temperature 10 C to 40 C humidity 20 to 80 Check the system clock approximately once per month Use of a time server NTP server is recommended if high accuracy timing is required by the system If you notice that the system clock runs significantly faster or slower over time even after adjustment contact the store where you purchased the product or your maintenance service company for repair e In order to get the server and internal devices to work properly we recommend you store the server at room temperature Observe the storage conditions Temperature 10 C to 55 C Humidity 20 to 80 to store the server No condensation of moisture Express5800 GT110d S User s Guide 21 Precautions for Use Be Sure to Read e If this server internal optional devices and media set for the backup devices tape cartridges are moved from a cold place to a warm place in a short time condensation will occur and cause malfunctions and failures when these are used in such state To protect important stored data and property make sure to wait for a sufficient period to use the server and components in the operating environment Reference Time effective at avoiding c
80. ly one Physical Device e Understand the characteristics of each RAID Controller such as available RAID levels or Hard Disk Drives and choose an appropriate RAID Controller Logical Drives except for RAIDO have a smaller usable capacity compared to the total capacity of the Hard Disk Drive in the Logical Drive while disk reliability increases To configure the system you can use either a software controlled on board RAID Controller LSI Embedded MegaRAID or a hardware controlled optional RAID Controller N8103 128 129 1 30 134 To use this RAID System jumper settings on motherboard and backplane are required For the location of the jumpers and setting refer to the following Jumper settings on the motherboard and backplane required to use the RAID Controller LSI Embedded MegaRAID or optional RAID Controllers N8103 128 129 130 134 are described in the images below EJ pba 321 321 Enabled Disabled SWRAID jumpers Motherboard 54 Express5800 GT110d S User s Guide Chapter 2 Preparations 1 Installing Internal Optional Devices wb Bh 1f 06669006909066990 8668666596 sol j 990 EIN gp BASRA coe See See E29 o RO ALAS eese eo O a E of Hm sas qma utn a op w SB Urt S B3 toam 9 amp LY gn e a E 8 2 On board SATA 3 controller Backplane for 2 5 inch Har
81. midity 20 to 80 and no condensation Temperature 10 to 55 C Humidity 20 to 80 and no condensation Supported OSs Included parts 1 For Linux OS onboard RAID feature is not supported 2 Can be optionally expanded to two ports 3 Service Pack2 or later Windows Server 2008 R2 Standard Windows Server 2008 R2 Enterprise Windows Server 2008 R2 Foundation Windows Server 2008 Standard Windows Server 2008 Enterprise Windows Server 2003 R2 Standard x64 Edition Windows Server 2003 R2 Standard Edition Windows Server 2003 Standard Edition Red Hat Enterprise Linux 5 Server x86 Red Hat Enterprise Linux ES 4 x86 Red Hat Enterprise Linux 5 Server EM64T Red Hat Enterprise Linux ES 4 EM64T 104 keyboard two button mouse with scroll wheel air duct rubber feet EXPRESSBUILDER DVD Getting Started screws for device Power code 141 Express5800 GT110d S User s Guide Chapter 4 Appendix 2 Interrupt Lines 2 Interrupt Lines Interrupt lines are assigned as factory settings as shown below Use this table as a reference when you add optional devices e Interrupt lines As factory settings interrupt lines are assigned as follows Lua Porpnorai Doves Convoton ma _Poripheral Device Convene BIS T gt fame gt a o esonacer coman 4 jewnemaen de o o BOR NEN KE a ON E o e o 142 Express5800 GT110d S User s Guide
82. nal Optional Devices 1 7 4 Removal Remove a DIMM in the following procedure Note 1 Refer to steps 1 to 5 in Chapter 2 1 3 Overview of Installation and Removal for preparations 2 Rotate both levers of the target DIMM slot outward The DIMM is unlocked 3 Remove the DIMM by pulling it out from the slot in a straight direction 4 Assemble the server 5 Turn on the server and confirm that no error messages are displayed on POST If any error message is displayed refer to Chapter 3 1 Post Error Message in Maintenance Guide 6 If you replaced a broken DIMM select Yes in Memory Configuration Memory Retest of the Advanced menu After that select Save Changes and Exit to reboot 7 Setthe paging file size to the recommended value Total memory size x 1 5 or more If using a Windows OS refer to Chapter 1 7 1 Specifying Memory Dump Settings Debug Information in Installation Guide Windows For other OS consult the manual provided with the operation system or contact the store where you purchased it or your maintenance service company Express5800 GT110d S User s Guide 53 Chapter 2 Preparations 1 Installing Internal Optional Devices 1 f Use of Internal Hard Disk Drives in the RAID System This section describes how to use the Hard Disk Drives installed in the HDD cage at the front of the server in the RAID System Important Note Tips e Logical Drives can be created even with on
83. nector when mounting the internal USB device Use internal USB cable K410 245 00 to connect the device Motherboard Internal USB connector USB device gt USB cable K410 245 00 Express5800 GT110d S User s Guide 111 Chapter 2 Preparations 1 Installing Internal Optional Devices 1 15 2 Power cables The illustration below shows an example of connecting the power cables Power cables other than those shown here are not used by the devices 1 For 3 5 inch Hard Disk Drive models P4 Optical disk drive P1 Motherboard Power cable P10 2 For 2 5 inch Hard Disk Drive models P3 a HDD TL lt Optical disk drive P11 lt Optional device P4 Motherboard Power cable 112 Express5800 GT110d S User s Guide Chapter 2 Preparations 1 Installing Internal Optional Devices 1 16 Attaching the Front Bezel You can attach the front bezel by reversing the removal procedure Insert the three tabs on the lower part of the front bezel into the holes on the front of the server and then push the upper part of the front bezel toward the server to lock with release tabs 113 Express5800 GT110d S User s Guide Chapter 2 Preparations 1 Installing Internal Optional Devices 1 17 Installing the Side Cover You can attach the side cover by reversing the removal procedure Make sure that hooks
84. nes ia itte a e Ee oe Eee eth 141 Express5800 GT110d S User s Guide Notations Used in This Document Notations Used in This Document Notations used in the text In addition to safety related symbols urging caution 3 other types of notations are used in this document These notations have the following meanings Indicates critical items that must be followed when handling the server or operating software If the procedures described are not followed server failure data loss and other serious malfunctions could occur Indicates items that must be confirmed when handling the server or operating software Indicates information that is helpful to keep in mind when using this server Optical disk drives This server is equipped with one of the following drives depending on the order at the time of purchase These drives are referred to as optical disk drives in this document e DVD ROM drive e DVD Super MULTI drive Hard Disk Drives Unless otherwise stated Hard Disk Drives HDD described in this document refer to the following e Hard disk drives HDD e Solid state drive SSD Removable media Unless otherwise stated removable media described in this document refer to the following e USB memory e Flash FDD N Express5800 GT110d S User s Guide Notations Used in This Document Abbreviations of Operating Systems Windows Operating Systems are referred to as follows
85. nlsi 11 Lats edio S a a a e a a 11 AA precautions for Use Be Sure to Read c ooccicoccccconoconocononcnnnononcnnnonnnnnnnn cnn rnnnn nn anno rn rr unnt nennen enne enne nnns 12 SA irure cir PERRA tette ed LL e E e tenista dre 12 Symbols used in this document and on warning labels essen 13 IARE n 14 General zeit er error nce pee E DII UELLE S 14 Power supply and power cord USC c ecceceeeeeeeeneeceeeeeeeeeeeaeceeeeeeeseeaeaeeeeeeeseeqaeaeeeeeeesecseceeeeeenees 15 Installation relocation storage and connection ssssssssessssssssseseeeneneeeenen enn 17 Cleaning and working with internal devices oooooococnonicococcccncccconononoconcnonnnanonncnnnnnnnnnnn nn cnn nennen 18 DUNG OMSK AU OM ta aseeseen eet ees Roe centes xd cau Paca tenti Pea e ee nA Sete rs Sese de pci ee enero 19 WarnitiG labGlS T E A tenschcascsasacekaa tencsaancs adh idadagqasatersdesandsscsceeastccdssauapieebecdegessitere 20 Handling precautions for proper OperatiOMS ooooooccccccnncccccoccncnccononononnnnncnnannnnnnnnnnnnnnnn non ncnn cnn anar nn nennen nnne 21 Chapter 1 General DescriptiOn eiecti a ld ea 24 P A oiala eilo n Mee Em 25 Bes i Soa E ui ria be A AA a ween 26 Bs Standard Features toL cos can e rena e cL docu caia dora a id edad 27 3 1 Management Features ccceccccccccececeecenecee cece eee
86. nnas power transmission wires and electromagnetic cranes is placed pres w Places where corrosive gas is present environments where there is sulfur vapor in the atmosphere or places where chemicals are nearby or may be accidentally sprayed over sp x Places where the power cords or interface cables might be stepped on or tripped over Do not install where there is power supply noise nearby such as contact sparks when turning power on or off during power relays If you must install the server close to such equipment have your maintenance service company separate power cables or install noise filter Chapter 2 Preparations 2 Ideal Location and Connection 2 1 1 Preparation for installation 1 For vertical mounting For vertical use of the server the stabilizer attached to the bottom of the server must be removed to change the orientation as instructed below Also be sure to attach the air duct for cooling on the top of the server a Removing installing the stabilizer Removing the stabilizer Release the lock plate and slide it in the direction of the arrow to remove Lock plate Lock plate Installing the stabilizer Insert the tab of the stabilizer into the slot of the server as shown in the image below A A Tabs F 2 each e a Orient the stabilizers 2 each so that they will fit in the slot of the server Express5800 G
87. ondensation in winter 10 C or more differences between the room temperature and atmospheric temperature Disk devices Approximately 2 to 3 hours Tape media Approximately 1 day e For optional devices we recommend you use our NEC products Some memory or Hard Disk Drive manufactured by other companies are supported for use with this server however you will be charged to repair failure or damage caused by use of such products even within warranty period Tips Maintenance service We offer periodic diagnosis and maintenance services by staff with expert knowledge of the maintenance of this server We recommend that you make a periodic maintenance service contract with your maintenance service company to keep your server in good condition Express5800 GT110d S User s Guide Precautions for Use Be Sure to Read Tips for your health and safety Using a computer extensively may affect different parts of your body Here are tips you should follow while working on a computer to minimize strain on your body Keep proper posture The basic body position for using a computer is sitting straight with your hands on the keyboard parallel with the floor and your eyes directed slightly downward toward the monitor With the proper posture described above no unnecessary strain is applied on any part of your body in other words when your muscles are most relaxed Working on the computer with bad posture such as hunching over or being too cl
88. onnect the monitor The LED indicates the transfer speed of the LAN port used 6 DUMP switch for management Press this switch to obtain a memory dump Important Consult with the service technician of your maintenance service company to control DUMP switch If you control the switch while it is working fine the system will stop Tips N8117 01A additional RS 232C connector kit can be installed on air cooled models only Express5800 GT110d S User s Guide 33 Chapter 1 General Description 4 Names and Functions of Parts 4 3 Internal view 1 2 3 4 5 34 3 5 inch Hard Disk Drive model air cooled type Power supply unit CPU cooling fan DIMM slots 3 5 inch Hard Disk Drive Optical disk drive 6 6 5 8 9 10 Bottom fan 3 5 inch device bay Motherboard PCI slot Rear fan Express5800 GT110d S User s Guide Chapter 1 General Description 4 Names and Functions of Parts 3 5 inch Hard Disk Drive model water cooled type 12 5 6 7
89. or 21 Fan 2 connector for rear fan 22 Fan 3 connector for bottom fan radiator rear fan 13 Internal Flash Memory connector yA 23 Fan 4 connector for additional 2 5 inch HDD cage 14 USB connector for front 15 LED SW connector 16 COM B connector for N8117 01A fan radiator front fan 24 Fan 5 connector for 2 5 inch HDD cage 25 PM BUS connector 38 Express5800 GT110d S User s Guide Chapter 1 General Description 4 35 Status Indicators 4 Names and Functions of Parts This section explains the indication and meanings of the server LEDs 3 5 inch Hard Disk Drive model B i a Conon LH LLLI Power LED DISK access LED Status LED Optical disk access LED Front view 2 5 inch Hard Disk Drive model Disk LED ibe Power LED Disk access LED LL Status LED Optical disk LED Front view LINK ACT LED A E UH EUE Speed LED EE Rear view azaz EE oE LINK ACT LED gt eu Speed LED Wa EUR EUG Rear view Express5800 GT110d S User s Guide 39 Chapter 1 General Description 4 Names and Function
90. or a power leak Al Precautions for Use Be Sure to Read Use a grounded outlet with the specified voltage Use of an improper power source Symbols used in this document and on warning labels Attentions Indicates the presence of electric shock hazards Indicates the presence of a hot surface or component Touching this surface could result in bodily injury A Indicates there is a risk of explosion Indicates there is a risk of fire or fumes Prohibited Actions Do not disassemble repair or modify the server Otherwise an electric shock or fire may be caused Do not touch the component specified by this symbol Otherwise an electric shock or burn may be caused Do not place the server near the fire Otherwise a fire may be caused Mandatory Actions Unplug the power cord of the server Otherwise an electric shock or fire may be caused Make sure equipment is properly grounded Otherwise an electric shock or fire may be caused Express5800 GT110d S that can result in pinching or other bodily injury Indicates the presence of mechanical parts that can result in bodily injury Indicates the presence of mechanical parts Indicates the presence of laser beam that cause blindness Indicates a general notice or warning that cannot be specifically identified Do not touch the server with wet hand Otherwise an electric shock may be caused Do not use the server in the place where wate
91. ose to the monitor could cause fatigue or deteriorated eyesight Adjust the angle of your display Most display units are designed for adjustment of the horizontal and vertical angles This adjustment is important to prevent the screen from reflecting bright lights and to make the display contents easy to see Working without adjusting the display to a comfortable angle makes it difficult for you to maintain a proper posture and you will get tired easily Adjust the viewing angle before use Adjust the brightness and contrast of the display Display screens have functions to control brightness and contrast The most suitable brightness contrast depends on age individuals and environment so adjust it to suit your preferences A too bright or too dark display is bad for your eyes Adjust the angle of keyboard Some keyboards are ergonomically designed which allow the angle to be adjusted Adjusting the angle of the keyboard is effective to reduce tension on your shoulders arms and fingers Clean your equipment Keeping your equipment clean is important not only for the appearance but also for functional and safety reasons A dusty monitor makes it difficult to see the display contents so clean it regularly Take rest breaks When you feel tired take a break Light exercise is recommended Express5800 GT110d S User s Guide 23 This chapter introduces the features of this server and the name of each part 1 Introduction
92. portant Express5800 GT110d S User s Guide 47 Chapter 2 Preparations 1 Installing Internal Optional Devices 1 35 Removing the Front Bezel Remove the front bezel by using the following procedure 1 Refer to steps 1 to 3 in Chapter 2 1 3 Overview of Installation and Removal for preparations 2 Release the three release tabs on the front bezel in the direction of the arrow shown in the image and then pull the front bezel forward slightly until it comes off the frame 0 Important If you pull the front bezel forward too much you will break the lower hook Gently slide it to prevent damaging the equipment 3 Slide the front bezel upward to release the hooks that engaged with the three holes at the lower part of the server and take it off the server 48 Express5800 GT110d S User s Guide Chapter 2 Preparations 1 Installing Internal Optional Devices 1 6 Internal Flash Memory This section describes the procedure for installing the Internal Flash Memory 9 d Internal USB connector Z 1 6 1 Installation Install the Internal Flash Memory in the following procedure 1 Referto steps 1 to 5 in Chapter 2 1 3 Overview of Installation and Removal for preparations 2 Attach
93. r maintenance service company for maintenance 1 10 4 Configuration after installing Depending on the type of card installed you might need to use a utility the BIOS setup utility included with this server or a setup utility provided with the card following installation to modify server settings Follow the instructions in the manual provided with the card to specify the correct settings After turning the server power on the PCI bus numbers are scanned in ascending order If the option ROM installed in the card contains a BIOS utility the startup message banner is displayed in ascending order of the PCI bus numbers Express5800 GT110d S User s Guide 85 Chapter 2 Preparations 1 Installing Internal Optional Devices 1 10 5 Removal 86 Remove a PCI card connected to a PCI slot by using the following procedure 1 Refer to Chapter 2 1 3 Overview of Installation and Removal for preparations Remove the side cover while referring to Chapter 2 1 4 Removing the Side Cover Refer to installation step 4 to open the PCI slot retention Remove the card Attach the expansion slot cover and refer to installation step 7 to close the PCI slot retention Assemble the server N Oo oO o N Turn on the server and confirm that no error messages are displayed in POST If an error message is displayed take notes on the message and ask your maintenance service company for maintenance Express5800 GT110d S User s Guide Chapter
94. r or liquid may pour Otherwise an electric shock or fire may be caused Indicates a general prohibited action that cannot be specifically identified Indicates a mandatory action that cannot be specifically identified Make sure to follow the instruction User s Guide 13 Precautions for Use Be Sure to Read Safety notes This section provides notes on using the server safely Read this section carefully to ensure proper and safe use of the server For symbols refer to Safety precautions General A WARNING Do not use the server for services where human life may be at stake or high reliability is required This server is not intended for use in medical nuclear aerospace mass transit or other applications where human life may be at stake or high reliability is required nor is it intended for use in controlling such applications We disclaim liability for any personal injury and property damages caused by such use of this server Do not use the server if any smoke odor or noise is present If smoke odor or noise is present immediately turn off the server and disconnect the power plug from the outlet then contact the store where you purchased the product or your maintenance service company Using the server in such conditions may cause a fire Do not insert needles or metal objects Do not insert needles or metal objects into ventilation holes in the server or openings in the optical disk drive
95. ress5800 GT110d S User s Guide Chapter 2 Preparations 2 Ideal Location and Connection 2 2 2 Power cord Connect the provided power cord to the server Tips e To connect the power cord to a UPS connect it to the outlet provided at the rear of the UPS For details refer to the instruction manual supplied with the UPS e n order to link the power supply from the UPS with the power on off of this server the BIOS settings change might be required depending on the UPS to which the power cord of this server is connected In the BIOS Setup Utility select Server and then AC LINK to change the parameter to the appropriate value Express5800 GT110d S User s Guide 123 This chapter describes how to set up the server Turning on the Server POST Power On Self Test is explained in this section System BIOS Setup You can customize BIOS settings by following the instructions in this section EXPRESSSCOPE Engine 3 EXPRESSSCOPE Engine 3 provides useful features through the Baseboard Management Controller BMC EXPRESSBUILDER EXPRESSBUILDER helps you to install Windows and maintain the server Installing Software Components You can install Windows and bundled software by following the instructions in Installation Guide Windows Turning off the Server Turn off power when not using the server Express5800 GT110d S User s Guide Chapter 3 Setup 1 Turning on the Server Y Turning on the Serv
96. rface Display External dimensions Express5800 GT110d S 2C i3 2120 EXP281A N8100 1741F N8100 1742F 3 5 inch Hard Disk Drive model 2 5 inch Hard Disk Drive model Intel Core i3 processor i3 2120 3 30 GHz 3 MB No standard 1 Intel C204 Chipset Not pre installed 32 GB 8 GB x 4 DDR3 1333 SDRAM DIMM unbuffered x 1 ECC DDR3 1333 SD RAM DIMM with dual channel memory support Integrated in BMC more than 32 MB Not pre installed 3 5 inch SATA 4 TB 2 TB x 2 2 5 inch SATA 3 TB 1 TB x 3 2 5 inch SAS 2 7 TB 600 GB x 3 2 5 inch SATA 500 GB 100 GB x 5 option SATA RAID 0 4 standard option SATA RAID 0 1 standard RAID5 option SAS RAID 0 1 5 option Standard DVD ROM drive Option DVD SuperMULTI drive replaces the DVD ROM drive 3 5 inch Hard Disk Drive x 2 2 5 inch Hard Disk Drive x 3 1 slot PCI EXPRESS 1 slot x8 x16 PCI EXPRESS 2 slot x4 x8 socket Front 2 ports rear 4 ports internal 2 ports version 2 0 compatible 2 ports 100Base T 100Base TS 10Base T RJ 45 Management LAN port RJ 45 MINI D sub 15 pin 1 port 93 0 mm width x 386 5 mm depth x 363 0 mm height not including air duct stabilizer protrusions 190 0 mm width x 396 5 mm depth x 386 5 mm height air duct stabilizer protrusions included KAA Power supply 100 200 VAC 10 50 60 Hz 3Hz maw Environmental conditions When in storage 175 W Temperature 10 to 40 C Hu
97. rn it off Refer to Chapter 3 6 Turning Off the Server Disconnect the power cord from the outlet and the server Disconnect all cables connected to the connector at the rear Remove the side cover Refer to Chapter 2 1 4 Removing the Side Cover Remove the front bezel if applicable Refer to Chapter 2 1 5 Removing the Front Bezel Depending on the components to be installed or removed follow the procedure in order Refer to Chapter 2 1 6 Internal Flash Memory to 1 14 Backup devices Connect cables Refer to Chapter 2 1 15 Connecting cables Attach the front bezel Refer to Chapter 2 1 16 Attaching the Front Bezel Attach the side cover Refer to Chapter 2 1 17 Installing the Side Cover This is the end of the installation or removal procedures for internal optional devices Continue the setup with reference to Chapter 2 2 2 Connection Express5800 GT110d S User s Guide Chapter 2 Preparations 1 Installing Internal Optional Devices 1 4 Removing the Side Cover Remove the side cover by using the following procedure 1 Referto steps 1 to 3 in Chapter 2 1 3 Overview of Installation and Removal for preparations 2 Unlock the padlock attached to the chassis if applicable 3 Lay it so that the side cover faces upward Lay it down slowly and gently 4 Remove the side cover While pressing the two eject buttons slide the cover backward and lift it off Eject button Im
98. rom network Note 5 Ifa controller which has its dedicated BIOS such as a SCSI controller board is installed a message that prompts you to start the dedicated utility to set each board is displayed Example SCSI BIOS Setup utility Press Ctrl A for SCSISelect TM Utility The utility starts by pressing the Ctrl lt A gt keys Example If an optional RAID Controller is installed Press Ctrl H for Web BIOS The utility starts by pressing the Ctrl lt H gt keys Example If the jumper setting for an on board RAID Controller is enabled Press Ctrl M to Run LSI Software RAID Configuration Utility The utility starts by pressing the Ctrl lt M gt keys For details on the utility refer to the manual supplied with each optional board Depending on the configuration the message Press Any Key might appear to prompt a key entry This is a behavior of the BIOS of the optional board Continue to operate after checking the manual of the optional board 6 If you set a password at SETUP in the BIOS Setup utility the password entry screen appears upon successful completion of POST Up to three password entries will be accepted Three incorrect password entries disable the server to boot In such a case turn off the power and wait about ten seconds before turning on to boot the server Important Do not set a password before OS is installed 7 The OS starts when POST is completed Express5800
99. rs on the screen during POST NY LEC 2 If the Esc key is pressed the logo disappears and the details of POST are displayed Tips You can set it to show the details of POST to be displayed from BIOS menu without requiring the lt ESC gt key to be pressed From the System BIOS Setup set Quiet Boot to Disabled in the Boot menu 3 POST displays several types of message These messages let you know that the installed CPU or connected keyboard and mouse are detected Tips Depending on the installed PCI card configuration the memory capacity might be displayed less than actually installed physical memory This applies to the display of BIOS Setup utility or OS system information 126 Express5800 GT110d S User s Guide Chapter 3 Setup 1 Turning on the Server 4 After a while the following message is displayed on the screen Press F2 SETUP F3 Internal Flash Memory F4 ROM Utility F12 Network By pressing the designated function key following messages you can call the functions below upon completion of POST F2 key Run the SETUP For information on the SETUP refer to Chapter 3 2 System BIOS Setup F3 key Run EXPRESSBUILDER from Internal Flash Memory optional For information on EXPRESSBUILDER refer to Chapter 3 4 EXPRESSBUILDER F4 key Run the offline tool For information on the offline tool refer to Chapter 1 Maintenance 9 Offline Tools in Maintenance Guide F12 key Boot f
100. s Guide describes hazardous parts of the server possible hazards and how to avoid them Server components with possible danger are indicated with a warning label placed on or around them or in some cases by printing the warnings on the server In User s Guide or on warning labels WARNING or CAUTION is used to indicate a degree of danger These terms are defined as follows A WARNING Indicates there is a risk of death or serious personal injury Y CA UTION Indicates there is a risk of burns other personal injury or property damage Precautions and notices against hazards are presented with one of the following three symbols The individual symbols are defined as follows Attention This symbol indicates the presence of a hazard if Example the instruction is ignored An image in the symbol illustrates the hazard type Electric shock risk Prohibited This symbol indicates prohibited actions An image Example Action in the symbol illustrates a particular prohibited D action OS Do not disassemble Mandatory This symbol indicates mandatory actions An image Example Action in the symbol illustrates a mandatory action to avoid a particular hazard Disconnect a plug 12 Express5800 GT110d S User s Guide A label example used in this User s Guide Description of a warning Term indicating a degree of danger A WARNING Symbol to draw attention Use only the specified outlet may cause a fire
101. s of Parts 4 5 1 Power LED The power LED lights green while the server is on 4 5 2 Status LED 4 While hardware is operating normally the status LED lights green The status LED is off or lights flashes amber if there is a problem with hardware The following table lists status LED patterns their explanation and solution Tips Refer to the system event log SEL by using ESMPRO or the offline maintenance utility to view the cause of failure If shutdown processing can be performed via the operating system when you want to restart the system after turning the power off restart the system by performing shutdown processing If shutdown processing cannot be performed restart the system by resetting the system forcibly turning the power off or disconnecting and then connecting the power cord on PEN TUUM ibis diui AA Flashing green The server is operating with the memory in degraded Identify the device in degraded state by using the BIOS state setup utility SETUP and replace it as soon as possible An uncorrectable memory error has often occurred The power is off Turn on the server POST is in progress Wait for a while The STATUS LED will turn green after POST completes A CPU error occurred Turn the power off and then turn it on If the POST Abnormal CPU temperature is detected Screen displays any error message take notes of the message and contact your maintenance service Watchdog timer expir
102. sk Drives 8 Stabilizer To mount the server vertically install as shown in the image 9 Release tabs 3 at side of front bezel Tabs to unlock the front bezel Pull up to disengage the front bezel 10 Optical disk drive Reads data from or writes data to the disk The drive provides the following an eject button to eject the tray an LED that indicates Hard Disk Drive access and an eject hole for forcibly ejecting the tray 11 3 5 inch device bay The bay which can accommodate 3 5 inch device Express5800 GT110d S User s Guide 31 Chapter 1 1 2 3 4 5 6 7 32 General Description 2 5 inch Hard Disk Drive model 2 jj EE 4 mmm Soil m 7 12 Air duct To take air to cool the server POWER switch The switch to turn the server on and off Press once to turn on the server The Power LED lights green when it is on Press it again to turn off the server Hold down the switch for 4 seconds or more to forcibly turn off the server Power LED green amber This LED lights green when the power is ON Disk access LED green amber This LED lights or flashes green when the internal Hard Disk Drive is being accessed It lights amber when the drive is broken and flashes amber and green alternately when the array disk is being rebuilt Status LED green amber This LE
103. ssword a message prompt you to enter password will be displayed from the next time Enter password You can attempt password entry up to 3 times If you entered a wrong password 3 times operation stops You cannot operate further Turn off the power Saving changes If you finish configuration select Save amp Exit and then Save Changes and Exit to save changes and exit If you wish to exit without saving the changed parameters select Save amp Exit and then Discard Changes and Exit Or if you wish to restore the setting to default values select Save amp Exit and then Load Setup Defaults The default value might be different from the factory setting Express5800 GT110d S User s Guide 133 Chapter 3 Setup 3 EXPRESSSCOPE ENGINE 3 J EXPRESSSCOPE ENGINE 3 3 1 Overview EXPRESSSCOPE Engine 3 provides a variety of features using BMC Baseboard Management Controller which is a system management LSI EXPRESSSCOPE Engine 3 monitors the power unit fans temperature and voltage of the server If you have the management LAN port connected to the network you can remotely perform the following over a web browser or SSH client Manage the server Remotely control the keyboard video and mouse KVM Remotely access a CD DVD floppy disk ISO image USB memory To enable this feature the optional license for remote management N8115 04 is required 3 2 EXPRESSSCOPE ENGINE 3 Network configurat
104. store where you purchased the product or your maintenance service company Express5800 GT110d S User s Guide 41 Chapter 1 General Description 4 Names and Functions of Parts 4 5 7 Speed LED 51 252 sM This LED indicates which network interface is used The two LAN connectors for data transmission support 1000BASE T 100BASE TX and 10BASE T and the LED indicates which network interface is being used e Amber Operating with 1000BASE T e Green Operating with 100BASE TX e OFF Operating with 10BASE T The LAN connector used for management supports 100BASE TX and the LED flashes green during the operation 42 Express5800 GT110d S User s Guide This chapter describes preparations for using this server 1 Installing Internal Optional Devices You can skip this section if you did not purchase any optional devices 2 Ideal Location and Connection You must place the server in an ideal location and connect some cables following this section Express5800 GT110d S User s Guide 43 Chapter 2 Preparations 1 Installing Internal Optional Devices I Installing Internal Optional Devices This chapter describes the instructions for installing supported optional devices and precautions If you did not purchase any optional device requiring installation you may skip this section Important We recommend that optional devices be installed by a maintenance service staff from your maintenance service company who
105. th three screws from the rear side 2 After connecting the connection board place and fix the RAID Controller in the PCI slot paying attention not to disconnect the cable Installing a RAID Controller Install the RAID Controller into the PCI slot of the server RAID Controller Express5800 GT110d S User s Guide 71 Chapter 2 Preparations 1 Installing Internal Optional Devices Connecting the battery control cable Referring to the image below connect the battery control cable into the battery pack Check the orientation of the connector and connect the cable straight into the connector Make sure the connector is oriented correctly by checking the following two points Facing up the battery plate Blue line on the left Important When installing or removing an extra battery pay special attention not to apply excessive pressure on the bracket tab Otherwise the part may break 72 Express5800 GT110d S User s Guide Chapter 2 Preparations 1 Installing Internal Optional Devices Installing a battery pack to 2 5 inch Hard Disk Drive models 1 Remove the file device or blank panel For the blank panel pull it toward you while pressing the tab on the right 2 Remove the two screws from the blank cover 3 Pass the bracket containing the battery and which is connected to the remote cable through the opening from which the blank cover was removed Express5800 GT110d S User s Guide 73 Chapter 2 Prepar
106. the two screws from the blank cover 5 Remove the two screws from the blank panel and detach the rails 6 Attach the rails you removed in step 5 to the HDD cage Use the screws you removed from the blank panel Important Keep the removed blank panel for future use Express5800 GT110d S User s Guide 95 Chapter 2 Preparations 1 Installing Internal Optional Devices 7 Push the HDD cage halfway in the server Do not push the cage in completely as the cable has to be connected to the device 8 Connect the fan cable of the HDD cage to the motherboard For details refer to Chapter 2 1 15 Connecting cables Eloisa SE Connector of the motherboard to be connected FAN 4 9 Push the HDD cage all the way into the server until it locks with a clicking sound 10 Use screws to fix the blank cover to the HDD cage attached in step 9 Use the screws you removed earlier 11 Connect cables For details refer to Chapter 2 1 15 Connecting Cables 96 Express5800 GT110d S User s Guide Chapter 2 Preparations 1 Installing Internal Optional Devices 1 12 2 Installation Follow the procedure below to install the 2 5 inch Hard Disk Drive 1 Unlock the security key and open the door of the Hard Disk Drive bay 2 Install the Hard Disk Drive in the HDD cage With the handle of the Hard Disk Drive tray fully open insert th
107. tor set the termination resistance of the device to OFF 2 Refer to Chapter 2 1 3 Overview of Installation and Removal for preparations 3 Remove the side cover and front bezel while referring to Chapter 2 1 4 Removing the Side Cover and 1 5 Removing the Front Bezel 4 While pressing the tab on the right pull the blank panel out 5 Remove the four screws from the blank panel and detach the rails 6 Attach the rails to the backup device Important 102 Express5800 GT110d S User s Guide Chapter 2 Preparations 1 Installing Internal Optional Devices 1 14 2 7 Donot push the backup device in completely as the cable has to be connected to the device 8 Connect the interface cable and power cable to the installed 3 5 inch device For more information refer to Chapter 2 1 15 Connecting cables 9 Push the device all the way until it locks with a clicking sound 10 Assemble the server 11 For SCSI devices use the BIOS utility of the SCSI controller and specify the transfer rate and other settings For more information refer to the manual provided with the SCSI controller 12 Install device drivers for installed devices as needed For more information refer to the manual provided with the device Removal You can remove the backup device by reversing the installation procedure If the devices are to remain removed attach the stored blank panel Express5800 GT110d S User s Guide 103
108. troller N8103 128 129 130 134 has been added Connecting to a RAID Controller N8103 128 129 130 134 requires a dedicated cable K410 253 00 for use with RAID Controllers Install the Hard Disk Drives in order from the bottom Motherboard RAID Controller N8103 128 129 130 134 Optical disk drive LED connector al 8 a SATAI emmmmm Internal SATA cable K410 253 00 SATAO aS SATA2 gt E SATAS HH Battery cable attached to the expansion battery SATA4 gt E SATA5 mmmmmE SATA cable for use with the optical disk drive Ww CI LED cable attached to the K410 253 00 Express5800 GT110d S User s Guide 105 Chapter 2 Preparations 1 Installing Internal Optional Devices Important To the motherboard side LED connector Sl m Mottherboard rt TMT o 106 Express5800 GT110d S User s Guide Chapter 2 Preparations 1 Installing Internal Optional Devices b For2 5 inch Hard Disk Drive models e If a RAID Controller N8103 128 129 130 134 has been added If SAS or SATA Hard Disk Drives are installed and used in a RAID System with a RAID Controller N8103 128 129 130 134 the dedicated cable K410 180 00 is required Install Hard D
109. ts of this document may change without prior notice 3 Do not make copies or alter the document content without permission from NEC Corporation 4 Every effort has been made to ensure the completeness of this document However if you have any concerns or discover errors or omissions please contact your retailer 5 Regardless of these 4 items NEC Corporation assumes no responsibility for effects resulting from operations 6 The sample values used in this document are not the actual values Keep this document nearby so that you may refer to it as necessary Latest editions This document was created based on the information available at the time of its creation The screen images messages and procedures may differ from the actual screens messages and procedures Substitute as appropriate when content has been modified The most recent version of User s Guide as well as other related documents is also available for download from the following website http www nec com Express5800 GT110d S User s Guide 11 Precautions for Use Be Sure to Read A Precautions for Use Be Sure to Read The following provides information required to use your server safely and properly For details of names in this section refer to Names and Functions of Parts in this document Safety precautions Follow the instructions in this document for the safe use of the NEC Express server This User
110. was detected Contact your maintenance service company An error was detected on either of the Hard Disk Drives An error is detected with Node Manager 4 5 3 Disk access LED lj The disk access LED lights or flashes green when an internal Hard Disk Drive or the optical disk drive is being accessed lf a 2 5 inch Hard Disk Drive model is used in RAID System by using an optional RAID Controller the LED lights amber and green alternately when the Hard Disk Drive failed and flashes when it is being rebuilt Tips For 3 5 inch Hard Disk Drive model the LED does not light flashes amber when Hard Disk Drive is broken or being rebuilt 4 5 4 Optical disk access LED The ACCESS LED lights flashes when the media set on the optical disk drive is being accessed 45 5 Disk LED For 2 5 inch Hard Disk Drive model each drive has its respective LED When the Hard Disk Drive is accessed the LED lights flashes green In RAID System when a Hard Disk Drive failed the LED lights amber and then flashes amber when it is being rebuilt 4 5 6 LINK ACT LED 41 2252 M This LED indicates the state of the standard network port If the server and HUB is supplied with power and connected properly the LED is on LINK If the network port is transmitting receiving data the LED flashes ACT If the LED does not turn on in LINK state check the cable or connection If the LED remains off the network LAN controller may be defective Contact the
111. xoocnonin aid idea 85 10 5 SN A ON 86 1 10 6 Installing the N8117 01A expansion RS 232C connector kit 87 LAT 3 54nch Hard Disk Drive cerir oninia a i A e a a Ee adah 90 NH A E E E E cenaeientde dt cvbece 91 1 11 2 Removal RE eMe in 93 1 12 2 5 inch Hard Disk Drive cit E ede eo necne te 94 1 12 1 Installing an expansion 2 5 inch HDD cage sessee eme 95 112 2 Jnstallation o t t ide e pte e dile pet te teo ette eni idet 97 1 12 3 ON 98 1 12 4 Removing the 2 5 inch HDD cage for additional drives eseees 98 1 13 Optical Disk Drive inei ate co e A core de ERIT Ee pe dede eed dot 99 13 1 Replacing AVES uui rrt beers tie peractae bu eu urb cu iib e irn Ee dba EE 99 1 13 2 Removal deu A idad 99 1 14 Backup devices etie eerie alicia 100 I4 lnstallati ni ur eee D tede eei LEA Eee ende UM AE bees OSEE HARE ENDS 101 L4 2 REMOVAL rti ote ia a ee De IOS eqni etre Delo de Dade dete 102 LES Connecting cables cede eere Te e t rre E Pr rb RUE ie n 103 1 15 1 Interface cables ug eicere E 103 1 15 2 Power cables iere tede ici ted a 111 4 16 Attaching the Front Bezel cooooconnnncicnonocccserccinen nseries 112 FAG Installing the Side Cover uc em deponi ae 113 Ideal Location and Connection 2 uere Re eee s 114 2 1 ldeallocation for the server cete dede dee ede Inner ble deed ete dn e det decade 114 2 1 1 Preparation for installation essseee
112. y Press the lt Esc gt key to go back to the original screen 130 Express5800 GT110d S User s Guide Chapter 3 Setup 2 System BIOS Setup O lt F2 gt key If you press this key the following window appears If you select Yes the previous parameter s are restored Load Previous Values Yes No O F3 key If you press this key the following window appears If you select Yes restore the parameters of the currently selected item to the default setting This might be different from the parameters configured before shipment Load Setup Defaults Yes No O F4 key If you press this key the following window appears If you select Yes the parameter you configured is saved and SETUP closes Save configuration and exit Yes No Express5800 GT110d S User s Guide 131 Chapter 3 Setup 2 System BIOS Setup 2 4 Cases that Require Configuration Only if a case applies to any of following cases use the SETUP utility to change a parameter which was configured as factory setting Other than cases described below do not change the settings A list of SETUP parameters and factory settings are described in Chapter 2 1 Details of System BIOS in Maintenance Guide UPS Powerlink 132 Change date and time Main gt System Date Configurable on OS Main gt System Time On Off NumLock on power ON Boot gt Bootup Numlock State On Off the function to

Download Pdf Manuals

image

Related Search

Related Contents

Operating Instructions Rheomat R 140  Gembird EG-PB12-01  Sitecom Internet Video Phone Set  Istruzioni per l`uso    ダウンロード  04402 MAXFIX ESP  MIC 10 シリーズ  La bibliographie sélective  

Copyright © All rights reserved.
Failed to retrieve file