1. Getting Started Safety Precautions Follow the instructions for your safety to use the NEC Express5800 server WARNING LABELS The warning labels are attached to components with possible danger or their vicinity in your server to inform the user that a hazardous situation may arise when operating the server Do not intentionally remove or damage any of the labels If you find any labels totally partially removed or illegible due to damage contact your service representative SAFETY NOTES Read the following instructions carefully to ensure proper and safe use of the server Refer to Chapter 1 of your User s Guide for detail AX Warning Failure to heed this sign could result in serious injury or death e Do not use the server for services where critical high availabil ity may directly affect human lives e Do not use the server if any smoke odor or noise is present e Keep needles or metal objects away from the server e Do not use the server in any unapproved place e Always install the server on a rack conforming to the relevant standard e Do not hold the power plug with a wet hand e Do not connect the ground wire to a gas pipe e Disconnect the power cord s before installing or removing the server e Do not disassemble repair or alter the server e Do not remove the lithium battery e Disconnect all the power plug before accessing inside the server or connecting the peripherals Caution Failure to h
2. can damage disk drives boards and other parts This system can withstand normal levels of environmental ESD while you are installing hard disk drives However we recommend that you do all procedures in this in struction only at an ESD workstation or provide some ESD protection by wearing an antistatic wrist strap attached to chassis ground any unpainted metal surface on your system when handling parts See the back side to continue the setting up 85 6 1272 4141 161 00 Connecting the Peripherals Connect the peripherals with the serverRefer to Chapter 3 of your User s Guide for detail Serial interface Front panel Serial interface device LAN devices LAN device SB device Server manage ment port 5 Connect the power plug to the wall outlet after completing all connecii 1 Any USB keyboard and mouse are not supported 2 For console of a management PC only 3 Use the provided branch cable 4 Connect the power cord s to a circuit breaker of 15 A or less Turning on the Server Press the POWER switch on the front of the server to power up the server If your server does not include Network Operating System NOS software use the DOS diskettes to boot up the prompts indicating your system is operational WO 0O LORO O ooo o00c o O POWER Switch POWER LED Configuring the Server Configure the server with the BIOS Setup Utility and RAID Configurat
3. eed this sign could result in personal injury or damage to properties e Keep water or foreign matter away from the server e Plug into a proper power source e Do not connect the power cord to an outlet that has an illegal number of connections e Insert the power plug into the outlet as far as it goes e Use the authorized power cord only e Do not use the attached power cord for any other devices or usage e Never attempt to lift the server only by yourself e Do not install the server in any place other than specified e Do not install the server on a rack with leaving covers removed e Do not pinch your finger with rails or other components e Do not apply any load on the server pulled out from the rack e Do not connect any interface cable when the power cord of the server is plugged into a power source e Do not use any unauthorized interface cable e Avoid installation in extreme temperature conditions e Make sure of complete board installation e Do not touch any electrical components inside the server during the hot swap replacement e Do not pull out or remove the server from the rack unnecessarily e Do not touch the fan blades when moving e Avoid contact with the server during thunderstorms e Keep animals away from the server e Do not place any object on top of the server e Do not remove the cooling fans Checking the Accessory Box The accessory box contains Server Front bezel Security key Branc
4. ess to the front panel switches the front panel USB and serial port the hot swap drive bays and the hot swap power supplies Refer to Chapter 2 of User s Guide for detail instruction A A Unlocked Locked Position Position Your server installation is now complete FCC STATEMENT This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio fre quency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense CE STATEMENT Warning This is a Class A product In domestic environment this product may cause radio interference in which case the user may be required to take adequate measures EN55022 BSMI STATEMENT eens ae PAW A ei gt ERER EP RF gt FRE SS Rie gt ESSA FE gt FS eRe RRM RASH BONE o NEC Express5800 Web Site http www nec co jp express nec Gee Cae hi a z z NEC Express5800 Web Site as raci du ess Dri br July Home Products Pr vers Lib
5. h cable PS 2 Power cord Power relay cable IDE cable Screws of internal backup device 4 pcs NEC EXPRESSBUILDER DVD containing the setup utility and system documentation DianaScope Additional Server License 1 License of DianaScope E Getting Started Chinese version E Getting Started English version this guide Save the packing material and carton box in case you ever need to repack and move the server to another location Your System Documentation To read and print the User s Guide insert NEC EXPRESSBUILDER DVD into the CD R DVD ROM drive ona system running Microsofts Windowse Windows 95 or later Windows NT 4 0 or later Use Adobe Reader to readsand print the documents If you do not have it install it from Adobe s internet site Click here to view or print User s Guide and other documents WE NEC EXPRESSBUILDER EXPRESSBUILDER NEC hh Read documents 9 Follow these steps to become familiar with your server documentation and to complete your installation successfully Installing the Server Follow the Chapter 3 in your User s Guide to install your server WARNING Anchor the Rack Cabinet The rack cabinet must be an chored to an unmovable support or a front stabilizer to pre vent it from falling over when one or more units are extended in front of it on slide assemblies The anchors must be able to withstand a force of up to 113 kg 250 Ibs You must also consider the we
6. ight of any other device installed in the rack Avoid Injury It is required that two people are present when lifting and assembling the server into a rack cabinet When installing the rack door make sure that hinge pins at top and bottom of the door are completely inserted into the rack Failure to follow this instruction may cause the door to fall to be broken and or to result in personal injury Restricted Access Location The server is intended for installation in a restricted access location mounted above a non combustible material Before you begin the rack installation review the following guidelines Do Not mM Locate a rack in a narrow space that would inhibit devices from being pulled out from the rack completely Locate the rack on a floor that cannot bear the total weight of the rack and devices mounted in the rack mM Locate the rack in a place where stabilizers cannot be installed or where the rack can be installed only after proper earthquake resistant is constructed Mm Locate the rack on an uneven or slanting floor Mm Locate the rack in an area that has drastic temperature change near a heater air conditioner or refrigerator mM Locate the rack where intense vibration may be gener ated Installing Hard Disk Drives Your server does not contain any hard disk drives Follow these steps to install the hard disk drive If you have additional adapter boards and devices for your server instal
7. ion Utilities Refer to Chapter 4 of your User s Guide for detail BIOS Setup Utility The BIOS Setup Utility is used to change system configuration parameters The utility is resident in the system FLASH memory and does not require a diskette or an operating system present to run You access the BIOS Setup utility when you turn on or reboot your system To run the BIOS Setup Utility perform the following procedure 1 Power on or reboot the system Press lt F2 gt to enter SETUP displays NOTE It might be displayed with another message The massage depends on the configuration of your server Press lt F2 gt to enter SETUP lt F12 gt to Network 2 Press F2 The BIOS Setup Utility starts and the Main Menu is displayed RAID Configuration Utility Your mother board includes the RAID Redundant Array of Inexpensive Devices controller ROMB Changing the RAID level on servers that include a preloaded Network operating System NOS will require reloading the NOS Refer to Chapter 4 of your User s Guide for running the configuration utility Additional Adapter Board BIOS Utilities If you have additional adapter boards install them and configure the adapter boards Follow the procedures in Chapter 9 of your User s Guide and vendor documents that come with the option Running the NEC EXPRESSBUILDER DVD 1 Run the NEC EXPRESSBUILDER DVD to E Run the maintenance utilities E Install the Network Operating System NOS
8. l them before putting the server in the location you have selected Follow procedures in Chapter 9 of your User s Guide plus installation inserts and vendor docu ments that come with the option E To order a disk contact your sales representative or dealer NEC Express5800 120hRj 2 NEC 12 2007 Rev 00 Mm Locate the rack where corrosive gas is generated ex the area where the vapor of sulphur is generated chemicals are nearby or chemicals may be sprayed accidentally Mm Place the rack on a carpet not subject to the anti static process mM Locate the rack where some objects may fall on the rack mM Locate the rack near a device that is generating intense magnetic fields Such as a TV radio broadcast commu nication antenna power transmission wire and electro magnetic crane If unavoidable contact your service representative to request proper shielding Mm Locate the rack where the power cord of the server must be connected to an AC outlet that shares other devices with large power consumption Mm Locate the rack next to equipment that generates power noise e g contact spark at power on power off of commercial power supply through a relay If you must install the server close to such equipment request your service representative for separate power cabling or noise filter installation 1 Install the rack cabinet 2 Install the server E Electrostatic discharge ESD
9. rary Buying About NEC Fault tolerant Server ia Trademarks EXPRESSBUILDER is trademarks of NEC Corporation Microsoft and Windows are registered trade marks of Microsoft Corporation in the United States and other countries Adobe Adobe logo and Adobe Reader are trademarks of Adobe Systems Incorporated All other product brand or company names used in this publication are the trademarks or registered trademarks of their respective holders To allow for design and specification improvements the information in this document is subject to change at any time without notice Reproduction of this document or portions thereof without prior written approval of NEC is prohibited Recycled paper is used Copyright 2007 NEC Corporation
10. with Express Setup M Create driver diskettes BIOS update diskettes and so on To run the NEC EXPRESSBUILDER DVD insert the DVD ROM into the DVD ROM device reboot the system and follow the screen prompts Refer to Installing the Operating System with Express Setup in your User s Guide for detail NEC EXPRESSBUILDER Step r gt Welcome to the NEC EXPRESSBUILDER writes as EXPRESSBUILDER at the following EXPRESSBUILDER helps you to install the Operating system Check the radio button and click Next If you want to install an Operating System or to build a RAID sub system select Perform the Express setup If you want to stop the operation of EXPRESSBUILDER select Exit EXPRESSBUILDER Perform the Express setup Create the OEM Disk for Windows C Save or Load the configuration data of the RAID controller C Load the optional driver into the EXPRESSBUILDER Exit EXPRESSBUILDER Version 5 01 001 00 Installing Application Software I Insert the NEC EXPRESSBUILDER DVD into the CD DVD ROM drive ona system running Microsoft Windows Windows 95 or later Windows NT 4 0 or later The Master Control Menu appears automatically Use this menu to E Read the documents E Install the management software Refer to Chapter 6 of your User s Guide for detail Installing Front Bezel To help prevent unauthorized system entry m or use the system includes full lockable front bezel The bezel provides acc

Download Pdf Manuals

image

Related Search

Related Contents

JVC KT-DB1000 User's Manual  SOFFIATORE BILLY GOAT FORCE Manuale Utente Accessori  Homelite HHC35A User's Manual  Tricity Bendix SIE553 User's Manual  ProForm 831.293040 Treadmill User Manual  取扱説明書  Manual de instalação e utilização  Lowe HF-125 User Manual  Samsung 173P PLUS Εγχειρίδιο χρήσης  V7 REPLACEMENT BATTERY TOSHIBA L955 OEM#PA5076U-1BRS PA5076U-1BRS PA5076U1BRS 4CELL  