Home
National Instruments PMA-1115 User's Manual
Contents
1. 01 United Kingdom 240 VAC eee 763064 01 Swiss 220 VAG stv ctanneath nesceied 763065 01 Australian 240 VAC 763066 01 Universal Euro 240 VAC 763067 01 Specifications AC DC Adapter TIPU aos oes n Packet wale igi 100 to 240 VAC 47 to 63 Hz 1 8 A maximum Outputiecs athe dilate AEE 12 VDC 5A LCD Wnputssstateiaccte facia ena 12 VDC 5A Type Mis Rhian kiana TFT LCD touch screen Auto power SWitch oo eect enees LCD goes into standby when no signal is present Power switchi eenen renek Left side of product STDBY Diagonal SiZe visiesidsatssastiniaisitasaien 15 in 38 11 cm Maximum resolution ccssceeeeseees 1024 x 768 National Instruments Corporation 7 NI PMA 1115 User Guide and Specifications Display ated iscieictenaieddsleiananiie Contrast ratio ccccceeeeesesesessceeeeeeeseeevees Brightness aisr Frame rate sooner aiii Control systeemien CONDECHVIY niesie inira Keyboard and Mouse Keyboard innein e Mechanical Environmental Welsh onion Aa R AE e LCD monitor folding angle i Maximum altitude Pollution Degree aei For indoor use only NI PMA 1115 User Guide and Specifications 8 11 97 x 8 98 in 30 41 x 22 81 cm 500 1 300 NTS 60 Hz typical 75 Hz maximum 16 2 M colors 160 up and down 160 right and left On screen display VGA or DVI I 105 key English language Touchpad USB 14 75 x 2 31 x 11 in 37 47 x 5 87 x 27
2. 1115 User Guide and Specifications Important Information Warranty The PMA 1115 is warranted against defects in materials and workmanship for a period of one year from the date of shipment as evidenced by receipts or other documentation National Instruments will at its option repair or replace equipment that proves to be defective during the warranty period This warranty includes parts and labor The media on which you receive National Instruments software are warranted not to fail to execute programming instructions due to defects in materials and workmanship for a period of 90 days from date of shipment as evidenced by receipts or other documentation National Instruments will at its option repair or replace software media that do not execute programming instructions if National Instruments receives notice of such defects during the warranty period National Instruments does not warrant that the operation of the software shall be uninterrupted or error free A Return Material Authorization RMA number must be obtained from the factory and clearly marked on the outside of the package before any equipment will be accepted for warranty work National Instruments will pay the shipping costs of returning to the owner parts which are covered by warranty National Instruments believes that the information in this document is accurate The document has been carefully reviewed for technical accuracy In the event that technical or typographica
3. 94 cm without mounting plate 5 0 kg 11 1b Up to 80 2 000 m 800 mbar at 25 C ambient 2 ni com Operating Environment Ambient temperature range 0 to 50 C Tested in accordance with TEC 60068 2 1 and TEC 60068 2 2 Meets MIL PRF 28800F Class 3 low temperature limit Relative humidity range 10 to 90 noncondensing Refer to Figure 8 for the correlation between temperature and humidity Tested in accordance with TEC 60068 2 56 Storage Environment Ambient temperature range 20 to 60 C Tested in accordance with TEC 60068 2 1 and IEC 60068 2 2 Relative humidity range 10 to 90 noncondensing Refer to Figure 8 for the correlation between temperature and humidity Tested in accordance with TEC 60068 2 56 National Instruments Corporation 9 NI PMA 1115 User Guide and Specifications Twb 39 C 100 90 _ 80 BS 3 60 a T 60 C g 40 H 39 Storage Storage Range Operation Range Range 20 10 20 0 10 20 30 40 50 60 Temperature C Figure 8 Temperature Humidity Relationship Shock and Vibration Operational SHOCK eee eeeeeeeeeees 10 g peak half sine 11 ms pulse Tested in accordance with TEC 60068 2 27 Random Vibration Operating wo cisseesiserestevevatescesagssscnsevesatess 5 to 500 Hz 0 31 gins Nomnoperating 0 0 eeeeeeeeeeseeeeeees 5 to 500 Hz 2 46 Sims Tested in accordance with TEC 60068 2 64 Nonoper
4. Instruments Corporation 11 NI PMA 1115 User Guide and Specifications Environmental Management National Instruments is committed to designing and manufacturing products in an environmentally responsible manner NI recognizes that eliminating certain hazardous substances from our products is beneficial not only to the environment but also to NI customers For additional environmental information refer to the NMI and the Environment Web page at ni com environment This page contains the environmental regulations and directives with which NI complies as well as other environmental information not included in this document Waste Electrical and Electronic Equipment WEEE EU Customers At the end of their life cycle all products must be sent to a WEEE recycling center For more information about WEEE recycling centers and National Instruments WEEE initiatives visit ni com environment weee htm Dx EFRA mR A CHE RoHS OQO PARA National instruments 4 EE TAA EP ih H EEEE A eS gt ROHS XF National Instruments F E ROHS AAR XK ni com environment rohs_china For information about China ROHS compliance go to ni com environment rohs_china NI PMA 1115 User Guide and Specifications 12 ni com Where to Go for Support The National Instruments Web site is your complete resource for technical support At ni com support you have access to everything from troubleshooting and application develo
5. the PMA 1115 7 Open the keyboard and LCD as shown in Figure 6 Install the supplied 6 32 x 3 8 flat head screws in the lower corners of the PMA 1115 1 6 32 x 3 8 flat head screws Figure 6 Installing the Lower Mounting Screws National Instruments Corporation 5 NI PMA 1115 User Guide and Specifications 8 If desired use the provided interlocking fastener to attach the AC adapter to the unit One suggested location is shown in Figure 7 Cable ties are also provided to organize the power cabling Figure 7 Suggested Location for Attaching AC Adapter 3 Note Do not place the AC adapter over any vent holes on the chassis cover as this may cause chassis cooling issues System Configuration The On Screen Display OSD controls on the side of the PMA 1115 provide standby functionality as well as standard video adjustments for the LCD The touch screen can be configured and calibrated through the TouchKit software found on the provided driver CD 3 Note The video resolution of the PXI Controller must be set to 1024 x 768 or lower NI PMA 1115 User Guide and Specifications 6 ni com Ordering Information To order the NI PMA 1115 kit or power cords refer to the following kit numbers NI PMA 1115 Kit NI PMA 1115 Portable Monitor ACCeSSOLY 0 ee eeeeseeeeeeeeeees 780215 01 Additional Power Cords North American 240 VAC eee 763068 01 Japanese 100 VAC sesoses 763634
6. AINST SYSTEM FAILURES INCLUDING BUT NOT LIMITED TO BACK UP OR SHUT DOWN MECHANISMS BECAUSE EACH END USER SYSTEM IS CUSTOMIZED AND DIFFERS FROM NATIONAL INSTRUMENTS TESTING PLATFORMS AND BECAUSE A USER OR APPLICATION DESIGNER MAY USE NATIONAL INSTRUMENTS PRODUCTS IN COMBINATION WITH OTHER PRODUCTS IN A MANNER NOT EVALUATED OR CONTEMPLATED BY NATIONAL INSTRUMENTS THE USER OR APPLICATION DESIGNER IS ULTIMATELY RESPONSIBLE FOR VERIFYING AND VALIDATING THE SUITABILITY OF NATIONAL INSTRUMENTS PRODUCTS WHENEVER NATIONAL INSTRUMENTS PRODUCTS ARE INCORPORATED IN A SYSTEM OR APPLICATION INCLUDING WITHOUT LIMITATION THE APPROPRIATE DESIGN PROCESS AND SAFETY LEVEL OF SUCH SYSTEM OR APPLICATION NI PMA 1115 User Guide and Specifications 14 ni com National Instruments NI ni com and LabVIEW are trademarks of National Instruments Corporation Refer to the Terms of Use section on ni com 1legal for more information about National Instruments trademarks Other product and company names mentioned herein are trademarks or trade names of their respective companies For patents covering National Instruments products refer to the appropriate location Help Patents in your software the patents txt file on your media Ofni com patents 2008 National Instruments Corporation All rights reserved 372430B 01 Apr08
7. E USER GUIDE AND SPECIFICATIONS NI PMA 1115 Portable Monitor Accessory This document includes an overview and specifications for the NI PMA 1115 Portable Monitor Accessory Overview The National Instruments PMA 1115 is a monitor and keyboard accessory for use with NI 8 slot PXI chassis It includes the following features e 15in high brightness TFT LCD touch screen panel e 105 key English keyboard and touchpad e Hardware for mounting to NI 8 slot PXI chassis e Anti glare tempered glass for LCD protection e VGA and DVI connectivity to the LCD e USB connectivity to the touch screen keyboard and touchpad e Sheetmetal construction e Universal AC DC power supply with Y cable for single wall connection e RoHS compliance For complete PXI system configuration information refer to ni com pxiadvisor Shipping Components The NI PMA 1115 kit includes the following items e NIPMA 1115 e Adapter plate and mounting hardware e Y splitter power cable e 12 V DC AC power adapter 7 NATIONAL p INSTRUMENTS e Video cabling to connect PMA 1115 to PXI controller e Right angle to vertical USB cable e Driver CD e Cable ties to organize power cabling e Interlocking fastener to secure power adapter Mounting The NI PMA 1115 includes a complete mounting kit for attachment to any NI 8 Slot PXI chassis This kit contains an adapter plate with provisions to relocate the carrying handle as well as all required fas
8. ating test profile exceeds the requirements of MIL PRF 28800F Class 3 NI PMA 1115 User Guide and Specifications 10 ni com Safety and Compliance Safety This product is designed to meet the requirements of the following standards of safety for information technology equipment e TEC 60950 1 EN 60950 1 e UL 60950 1 CSA 60950 1 3 Note For UL and other safety certifications refer to the product label or visit ni com certification search by model number or product line and click the appropriate link in the Certification column Electromagnetic Compatibility This product is designed to meet the requirements of the following standards of EMC for electrical equipment for information technology equipment e EN 55024 CISPR 24 e EN 55022 CISPR 22 e CE C Tick ICES and FCC Part 15 Emissions Class A Sy Note For EMC compliance operate this device according to product documentation CE Compliance This product meets the essential requirements of applicable European Directives as amended for CE marking as follows e 2006 95 EC Low Voltage Directive safety e 2004 108 EC Electromagnetic Compatibility Directive EMC 3 Note Refer to the Declaration of Conformity DoC for this product for any additional regulatory compliance information To obtain the DoC for this product visit ni com certification search by model number or product line and click the appropriate link in the Certification column National
9. intenance instructions owner s modification of the product owner s abuse misuse or negligent acts and power failure or surges fire flood accident actions of third parties or other events outside reasonable control Copyright Under the copyright laws this publication may not be reproduced or transmitted in any form electronic or mechanical including photocopying recording storing in an information retrieval system or translating in whole or in part without the prior written consent of National Instruments Corporation National Instruments respects the intellectual property of others and we ask our users to do the same NI software is protected by copyright and other intellectual property laws Where NI software may be used to reproduce software or other materials belonging to others you may use NI software only to reproduce materials that you may reproduce in accordance with the terms of any applicable license or other legal restriction Trademarks National Instruments NI ni com and LabVIEW are trademarks of National Instruments Corporation Refer to the Terms of Use section on ni com legal for more information about National Instruments trademarks Other product and company names mentioned herein are trademarks or trade names of their respective companies Patents For patents covering National Instruments products refer to the appropriate location Help Patents in your software the patents txt file on your media o
10. l errors exist National Instruments reserves the right to make changes to subsequent editions of this document without prior notice to holders of this edition The reader should consult National Instruments if errors are suspected In no event shall National Instruments be liable for any damages arising out of or related to this document or the information contained in it EXCEPT AS SPECIFIED HEREIN NATIONAL INSTRUMENTS MAKES NO WARRANTIES EXPRESS OR IMPLIED AND SPECIFICALLY DISCLAIMS ANY WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE CUSTOMER S RIGHT TO RECOVER DAMAGES CAUSED BY FAULT OR NEGLIGENCE ON THE PART OF NATIONAL INSTRUMENTS SHALL BE LIMITED TO THE AMOUNT THERETOFORE PAID BY THE CUSTOMER NATIONAL INSTRUMENTS WILL NOT BE LIABLE FOR DAMAGES RESULTING FROM LOSS OF DATA PROFITS USE OF PRODUCTS OR INCIDENTAL OR CONSEQUENTIAL DAMAGES EVEN IF ADVISED OF THE POSSIBILITY THEREOF This limitation of the liability of National Instruments will apply regardless of the form of action whether in contract or tort including negligence Any action against National Instruments must be brought within one year after the cause of action accrues National Instruments shall not be liable for any delay in performance due to causes beyond its reasonable control The warranty provided herein does not cover damages defects malfunctions or service failures caused by owner s failure to follow the National Instruments installation operation or ma
11. pment self help resources to email and phone assistance from NI Application Engineers National Instruments corporate headquarters is located at 11500 North Mopac Expressway Austin Texas 78759 3504 National Instruments also has offices located around the world to help address your support needs For telephone support in the United States create your service request at ni com support and follow the calling instructions or dial 512 795 8248 For telephone support outside the United States contact your local branch office Australia 1800 300 800 Austria 43 662 457990 0 Belgium 32 0 2 757 0020 Brazil 55 11 3262 3599 Canada 800 433 3488 China 86 21 5050 9800 Czech Republic 420 224 235 774 Denmark 45 45 76 26 00 Finland 358 0 9 725 72511 France 01 57 66 24 24 Germany 49 89 7413130 India 91 80 41190000 Israel 972 3 6393737 Italy 39 02 41309277 Japan 0120 527196 Korea 82 02 3451 3400 Lebanon 961 0 1 33 28 28 Malaysia 1800 887710 Mexico 01 800 010 0793 Netherlands 31 0 348 433 466 New Zealand 0800 553 322 Norway 47 0 66 90 76 60 Poland 48 22 3390150 Portugal 351 210 311 210 Russia 7 495 783 6851 Singapore 1800 226 5886 Slovenia 386 3 425 42 00 South Africa 27 0 11 805 8197 Spain 34 91 640 0085 Sweden 46 0 8 587 895 00 Switzerland 41 56 2005151 Taiwan 886 02 2377 2222 Thailand 662 278 6777 Turkey 90 212 279 3031 United Kingdom 44 0 1635 523545 National Instruments Corporation 13 NI PMA
12. r ni com patents WARNING REGARDING USE OF NATIONAL INSTRUMENTS PRODUCTS 1 NATIONAL INSTRUMENTS PRODUCTS ARE NOT DESIGNED WITH COMPONENTS AND TESTING FOR A LEVEL OF RELIABILITY SUITABLE FOR USE IN OR IN CONNECTION WITH SURGICAL IMPLANTS OR AS CRITICAL COMPONENTS IN ANY LIFE SUPPORT SYSTEMS WHOSE FAILURE TO PERFORM CAN REASONABLY BE EXPECTED TO CAUSE SIGNIFICANT INJURY TO A HUMAN 2 IN ANY APPLICATION INCLUDING THE ABOVE RELIABILITY OF OPERATION OF THE SOFTWARE PRODUCTS CAN BE IMPAIRED BY ADVERSE FACTORS INCLUDING BUT NOT LIMITED TO FLUCTUATIONS IN ELECTRICAL POWER SUPPLY COMPUTER HARDWARE MALFUNCTIONS COMPUTER OPERATING SYSTEM SOFTWARE FITNESS FITNESS OF COMPILERS AND DEVELOPMENT SOFTWARE USED TO DEVELOP AN APPLICATION INSTALLATION ERRORS SOFTWARE AND HARDWARE COMPATIBILITY PROBLEMS MALFUNCTIONS OR FAILURES OF ELECTRONIC MONITORING OR CONTROL DEVICES TRANSIENT FAILURES OF ELECTRONIC SYSTEMS HARDWARE AND OR SOFTWARE UNANTICIPATED USES OR MISUSES OR ERRORS ON THE PART OF THE USER OR APPLICATIONS DESIGNER ADVERSE FACTORS SUCH AS THESE ARE HEREAFTER COLLECTIVELY TERMED SYSTEM FAILURES ANY APPLICATION WHERE A SYSTEM FAILURE WOULD CREATE A RISK OF HARM TO PROPERTY OR PERSONS INCLUDING THE RISK OF BODILY INJURY AND DEATH SHOULD NOT BE RELIANT SOLELY UPON ONE FORM OF ELECTRONIC SYSTEM DUE TO THE RISK OF SYSTEM FAILURE TO AVOID DAMAGE INJURY OR DEATH THE USER OR APPLICATION DESIGNER MUST TAKE REASONABLY PRUDENT STEPS TO PROTECT AG
13. teners Complete the following instructions to install the NI PMA 1115 1 Place chassis on its left side as shown in Figure 1 Remove and discard the bottom feet and screws 1 Bottom feet Figure 1 PXI 8 Slot Chassis On Left Side 2 Using a small flat head screwdriver carefully remove the handle covers as shown in Figure 2 NI PMA 1115 User Guide and Specifications 2 ni com 1 Handle covers 2 Handle assembly Figure 2 Removing the Handle 3 Remove the handle from the chassis Retain the handle Discard the screws 4 Attach the adapter plate to the chassis using the supplied M4 x 8 pan head screws as shown in Figure 3 1 M4 x 8 pan head screws Figure 3 Installing the Adapter Plate National Instruments Corporation 3 NI PMA 1115 User Guide and Specifications 5 Reinstall the handle using the supplied 4 40 x 5 16 pan head screws as shown in Figure 4 Reinstall the handle covers by snapping them over the handle mounting plates 1 Handle covers 2 4 40 x 5 16 pan head screws Figure 4 Reinstalling the Handle and Handle Covers NI PMA 1115 User Guide and Specifications 4 ni com 6 Orient the chassis and PMA 1115 as shown in Figure 5 Install the remaining M4 x 8 pan head screws 1 M4 x 8 pan head screws Figure 5 Installing