National Instruments PXI-7811R User's Manual

image

Contents

1. National Instruments Lab VIEW Module Documents 323792A 01 Apr04 2004 National Instruments Corp All rights reserved
2. piIo17 DGND 17 51 DIO16 DGND 16 50 pio1s DGND 15 49 DIO14 DGND 14 48 DIO13 panD 13 47 piot2 pend 12 46 pio11 pend 11 45 pio10 pend 10 44 biog panp 9 43 bios panD 8 42 pio7 DGND 7 41 bios DeND 6 40 bios DGND 5 39 DIO4 DGND 4 38 DIO3 pend 3 37 DIO2 DGND 2 36 DIO1 pend 1 35 pioo Figure 2 PXI 7811R I O Connector Pin Assignments UN Caution Connections that exceed any of the maximum ratings of input or output signals on the PXI 7811R can damage the PXI 7811R and the computer NI is not liable for any damage resulting from such signal connections Refer to the PXI 78 1R User Manual for the maximum input ratings for each signal For detailed information about connecting I O signals refer to the NI 7811R User Manual Cabling Options Accessing the signals on the I O connectors requires at least one cable and one signal accessory Table 1 summarizes the National Instruments cables available for use with the NI 7811R device National Instruments Corporation 7 Getting Started with the NI 7811R Table 1 Cabling Options Cable Description SH68 C68 S For connecting signals from the DIO connector to the NI SCB 68 terminal block NSC68 5050 For direct connection of the NI 7811R and SSR backplanes Routes signals to connectors that attach directly to SSR backplanes Documentation Resources Refer to the following documentation for information about the LabVI
3. EW FPGA Module R Series hardware and VIs necessary for your application e LabVIEW FPGA Module Release Notes describes the software installation and other known software issues e LabVIEW FPGA Module User Manual describes the LabVIEW FPGA Module software and techniques for building applications in LabVIEW with the LabVIEW FPGA Module e PXI 7811R User Manual describes the electrical and mechanical aspects of the PXI 7811R device and contains information concerning its operation and programming e LabVIEW Help describes the VIs and function reference information e CompactRIO R Series Expansion System Installation Instructions describes how to install the CompactRIO R Series Expansion chassis and CompactRIO I O modules Where to Go from Here CompactRIO LabVIEW MXI National Instruments NI ni com and NI VISA are trademarks of National Instruments Corporation Product and company names mentioned herein are trademarks or trade names of their respective companies For patents covering National Instruments products refer to the appropriate location Help Patents in your software the patents txt file on your CD orni com patents Refer to the LabVIEW FPGA Module Release Notes for information about getting started with LabVIEW FPGA VIs and host VIs This document also provides examples for verifying that your software and hardware are properly installed To access this document select Start Programs
4. Getting Started with the NI PXI 7811R This document explains how to set up the National Instruments PXI 7811R device Introduction The PXI 7811R is an R Series reconfigurable I O RIO device with 160 digital I O DIO lines Traditional digital I O devices have a fixed functionality provided by an application specific integrated circuit ASIC but the PXI 7811R has a field programmable gate array FPGA that allows you to define device functionality and timing You can use the LabVIEW FPGA Module to graphically design the PXI 7811R timing and functionality without having to learn a low level programming language or a hardware description language HDL traditionally used for FPGA design With the LabVIEW FPGA Module you create or download a custom virtual instrument VI to the FPGA You can reconfigure the PXI 7811R device with a new VI at any time You can use the LabVIEW Real Time Module to communicate and control the PXI 7811R device while performing additional tasks such as real time floating point processing and data logging Sy Note Ifyou are using LabVIEW but not the LabVIEW FPGA Module you can create VIs that run in LabVIEW to control existing FPGA VIs but you cannot create new FPGA VIs The PXI 7811R device has Flash memory that you can use to store VIs You can configure VIs to load to the FPGA and to run when the device powers up Qr NATIONAL p INSTRUMENTS Required Items This section provides lists of
5. W Real Time Module for ETS from the LabVIEW Real Time CD Install LabVIEW FPGA from the LabVIEW FPGA CD Install the NI RIO device drivers Refer to the nstalling NI RIO Device Drivers section for driver installation instructions 3 Getting Started with the NI 7811R Installing NI RIO Device Drivers Complete the following steps to install the NI RIO device drivers that are included with the PXI 7811R device If you are using LabVIEW complete the installation instructions in the Jnstalling LabVIEW the LabVIEW Real Time Module for ETS and the LabVIEW FPGA Module section before installing the NI RIO device drivers 1 Run setup exe from the NI RIO CD and follow the setup instructions 2 Follow the onscreen instructions until the Feature Tree window appears 3 Inthe Feature Tree window select the components to install You must install NI VISA NI RIO and NI Measurement amp Automation Explorer MAX 4 Follow the onscreen instructions to complete the driver installation 5 Reboot your computer Installing Hardware This section describes how to unpack and install the PXI 7811R device You can install the PXI 7811R in any available peripheral slot in the PXI or CompactPCI chassis Sy Note You must install the NI RIO device drivers before installing the PXI 7811R device Unpacking The PXI 7811R device ships in an antistatic package to prevent electrostatic discharge from damaging device components To prevent such
6. damage when handling the device take the following precautions e Ground yourself using a grounding strap or by holding a grounded object such as your computer chassis e Touch the antistatic package to a metal part of the computer chassis before removing the devices from the package UN Caution Never touch the exposed pins of connectors Getting Started with the NI 7811R Remove the devices from the package and inspect the devices for loose components or any other sign of damage Notify NI if the devices appear damaged in any way Do not install damaged devices into the computer Store the PXI 7811R in the antistatic envelope when not in use 4 ni com Installation You can install the PXI 7811R in any available peripheral slot in the PXI or CompactPCI chassis Complete the following steps to install the PXI 7811R device 3 Note You must install the software before installing the hardware For software installation instructions refer to the Installing Software section 1 Power off and unplug the PXI or CompactPCI chassis 2 Make sure there are no lit LEDs on the chassis Wait for any lit LEDs to go out before continuing the installation Remove the filler panel for the peripheral slot 4 Ground yourself using a grounding strap or by touching a grounded object such as the PXI or CompactPCI chassis 5 Insert the PXI 7811R into the slot Use the injector ejector handle to fully inject the PXI 7811R into place 6 Sc
7. elop custom FPGA VIs for the PXI 7811R device NI RIO 1 1 or later included with the PXI 7811R PXI CompactPCI chassis and real time PXI controller One of the following host computers depending upon your application running Windows 2000 XP PC Laptop computer PXI CompactPCI embedded controller At least one cable and device for connecting signals to the PXI 7811R CAT 5 Ethernet crossover cable if the real time PXI system is not configured on a network To connect the PXI system to a network port use a standard CAT 5 10 100Base T Ethernet cable Installing Software The following instructions describe how to install the NI RIO device drivers and LabVIEW Installing LabVIEW the LabVIEW Real Time Module for ETS and the LabVIEW FPGA Module Use the following sequence when installing LabVIEW the LabVIEW Real Time Module for ETS and the LabVIEW FPGA Module For more detailed information about software requirements refer to the LabVIEW FPGA Release Notes If you are using NI RIO without LabVIEW skip these steps and complete the steps in the Jnstalling NI RIO Device Drivers section i Note You must install LabVIEW 7 0 or later and the LabVIEW modules you will be using with the NI 7811R before installing the NI RIO device drivers For LabVIEW installation instructions refer to the LabVIEW Release Notes National Instruments Corporation Install LabVIEW for Windows from the LabVIEW CD Install the LabVIE
8. rew the front panel of the PXI 7811R to the front panel mounting rails of the chassis 7 Visually verify the installation Make sure the PXI 7811R is not touching other devices or components and that the PXI 7811R is fully inserted into the slot 8 Plug in and power on the PXI or CompactPCI chassis Connecting Signals The PXI 7811R has four DIO connectors with 40 DIO lines per DIO connector Figure 1 shows the I O connector locations for the PXI 7811R The I O connectors are numbered starting at zero National Instruments Corporation 5 Getting Started with the NI 7811R NATIONAL E NSTRUMENTS NI PXI 7811R Reconfigurable I O 01A 0 YO1L9INNOD Old YOL9INNOD OIG T YOLDSNNOD OIG Z OLDANNOD gt Figure 1 PXI 7811R Connector Locations Getting Started with the NI 7811R 6 ni com Figure 2 shows the pin assignments for all I O connectors on the PXI 7811R DIO38 34 68 DIO389 pioss 33 67 D1037 pios4 32 66 pioss pios2 31 65 DIO33 pioso 30 64 DIO31 DIO28 29 63 DIO29 5v 28 62 DIO27 5v 27 61 DIO26 DGND 26 60 piozs DGND 25 59 DIO24 DGND 24 58 DIO23 panp 23 57 D1022 DGND 22 56 DIO21 panp 21 55 DIO20 DGND 20 54 DIO19 panp 19 53 DIO18 panpd 18 52
9. the items necessary for getting started using the PXI 7811R with Windows 2000 XP and the LabVIEW Real Time Module Documentation The NI PXI 7811R User Manual describes the electrical and mechanical aspects of the PXI 7811R device and contains information about device operation and programming This document is included on the NI RIO CD and is also available at ni com manuals LabVIEW Help is available in LabVIEW by selecting Help VI Function amp How To Help Windows 2000 XP Use the following items to set up and use the PXI 7811R with Windows 2000 XP Q PXI 7811R device Q The following software packages LabVIEW 7 1 or later LabVIEW FPGA Module 1 1 or later required to develop custom FPGA VIs for the PXI 7811R device NI RIO 1 1 or later included with the PXI 7811R Q PXI CompactPCI chassis and a PXI CompactPCI embedded controller running Windows 2000 XP or any computer running Windows 2000 XP and a MXI 3 link to a PXI CompactPCI chassis Q Atleast one cable and device for connecting signals to the PXI 7811R LabVIEW Real Time Module for ETS Use the following items to set up and use the PXI 7811R with the LabVIEW FPGA Module and the LabVIEW Real Time Module Q PXI 7811R device Q The following software packages LabVIEW 7 1 or later LabVIEW Real Time Module for ETS 7 1 or later Getting Started with the NI 7811R 2 ni com LabVIEW FPGA Module 1 1 or later required to dev