National Instruments CFP-20XX User's Manual
Contents
1. access to Read Only or Deny Access cFP 20xx Quick Start Guide 12 ni com Enteran IP address for the Time Server on the Servers tab of the System Configuration dialog box NewerkSetings system Sees shown in the figure at right Enter IP Addresses for Servers The time server is a networked computer that runs Time Sever MENEMA the National Instruments Time Service installed by FieldPoint Explorer Enter the IP address of the PC you are using When you finish configuring the controller the time has been set and Time Server is not a required parameter The cFP 20xx has an internal battery backed clock that provides consistent timestamps in the absence of a time server J Click OK in the System Configuration dialog box Click Yes when prompted to reboot the cFP 20xx When the cFP 20xx reboots it should appear in Remote System Explorer with the updated IP address and comment as shown in the following figure If it does not appear select View Refresh or refer to the user manual Y Remote System Explorer OI x File View Tools Help salaja eee e e IP Address Status Model Comment JA FFFFFFFF 130 164 44 35 Running cFP 2020 Process 1 K Highlight the serial number and click Select When the new host name or IP address appears in the Comm Resource Configuration dialog box of FieldPoint Explorer you can configure your devices and channels National Instruments Corporation 13 cFP 20xx Quic
2. 2 Phillips screwdriver and the 8 32 x 5 16 in countersink screws shipped with the clip s CAUTION Do not use screws longer than 5 16 in to fasten the DIN rail clip to the backplane B Insert one edge of the DIN rail into the deeper opening of the DIN rail clip C Press down firmly on the backplane to compress the spring until the clip locks in place on the DIN rail D Connect the PE ground terminal on the cFP BP x to safety ground UN CAUTION Disconnect power before removing the backplane from the DIN rail cFP 20xx Quick Start Guide 2 ni com Mounting the Backplane on a Panel A Fasten the panel mount plates to the back of the CFP BP x using a number 2 Phillips screwdriver and the 8 32 x 5 16 in countersink screws shipped with the kit CAUTION Do not use screws longer than 5 16 in to fasten the panel mount plates to the backplane lt B Bolt or screw the panel mount accessory to a panel C Connect the PE ground terminal on the cFP BP x to safety ground CAUTION Disconnect power before removing the backplane from the panel i 260 mm 10 25 in National Instruments Corporation 3 cFP 20xx Quick Start Guide Mounting the Backplane in a Standard 19 in Rack A Fasten the rack mount bracket to the back of the cFP BP x using the captive screws on the bracket B
3. Bolt the rack mount accessory to a standard 19 in rack C Connect the PE ground terminal on the cFP BP x to safety ground CAUTION Disconnect power before removing the backplane from the panel cFP 20xx Quick Start Guide 4 ni com 2 Install the cFP 20xx Controller on the Backplane A Make sure that no power is connected to the controller or the backplane B Make sure that the cFP 20xx controller is right side up with the NI logo at the top and align the captive screws on the controller with the holes on the backplane C Seat the card edge at the back of the controller in the card edge connector on the backplane D Press the controller firmly to seat it on the backplane E Using a number 2 Phillips screwdriver with a shank of at least 64 mm 2 5 in length tighten the captive screws to 1 1 N m 10 Ib in of torque National Instruments Corporation 5 cFP 20xx Quick Start Guide 3 Install 1 0 Modules on the Backplane A Align the captive screws on the 1 0 module with the holes on the backplane B Press firmly to seat the 1 0 module on the backplane C Using a number 2 Phillips screwdriver with a shank of at least 64 mm 2 5 in length tighten the captive screws to 1 1 N m 10 Ib in of torque D Repeat this procedure to install additional 1 0 modules on the backplane cFP 20xx Quick Start Guide 6 ni com Install Connector Blocks on the Backplane In order to co
4. The hierarchy includes all of the modules connected to the cFP 20xx The default name of each device found includes the name of the FieldPoint module followed by a space the sign and the address of the module for example cFP 2000 90 For each module found one 1 0 Item is created for each channel on the module and if all the channels are of the same type one 1 0 Item is created to represent all the channels on that module collectively cFP 20xx Quick Start Guide 14 ni com Device Configuration C To configure the hardware settings of a particular 1 0 module right click the device name and select Edit this device The Device Configuration dialog box appears as shown in the figure above For output modules you can choose settings for Watchdog Configuration Refer to the user manual for information about the network watchdog feature National Instruments Corporation cFP 20xx Quick Start Guide D Click Channel Configuration to access the Channel Configuration dialog box shown in the figure at right NOTE Configuration options vary by module The options listed here may not be available for some modules Make your selections in this dialog box as follows I Select the type of channel to show then select the channel s that you want to change To select more than one channel clear the One channel at a time checkbox Set the range and output values of the selected channel s Set
5. requires external power connect a power supply to the V and C inputs on the connector block for that module If you want to power field 1 0 devices from a connector block supply power to the connector block and then connect the connector block V and C output terminals to the field device Powering Up the cFP 20xx Check the DIP switches on the controller making sure that the RESET IP switch is not enabled Plug in each power supply to the Compact FieldPoint system The cFP 20xx runs a power on self test POST that takes ON 12345678 several seconds You should DIP Switches Functions Jo E User configurable on cFP 2000 and cFP 2010 disabled on cFP 2020 25 8 oou User configurable Desoria any DISABLE VI T aa ELAR SAFE MODE Oe En RESET IP see the POWER and STATUS LEDs come on After about five seconds the STATUS LED begins flashing The cFP 20xx is ready to be configured and you can install the FieldPoint software If you have already assigned an IP address to the cFP 20xx the STATUS LED turns off and the A B C and D LEDs come on for about 15 seconds as LabVIEW RT starts up Once they turn off the 1 0 module READY LEDs come on and the cFP 20xx is ready for use The total boot time for a configured system is 30 45 seconds If the STATUS LED does not light up as described here refer to the cFP 20xx and cFP BP x User Manual National Instrum
6. the deadband for data communication over the network The deadband setting is a percentage of the full scale range Set attributes for selected channel s by selecting the attribute and entering the desired value Send commands to the selected channel s by choosing a command and value and clicking Send Repeat this procedure for each channel you want to configure Click OK or click Apply to save the changes and continue to configure channels When you click OK or Apply the changes are immediately sent to the device and saved in its nonvolatile memory cFP 20xx Quick Start Guide 16 ni com Channel Configuration cFP TC 120 6 Type 1 Analog input 0 02 to 0 08 Volts x itcridog Value J Enable fThermocoupletype mh m Fm National Instruments Corporation cFP 20xx Quick Start Guide Saving Hardware Configuration as Power Up State When you are satisfied with the hardware configuration of the FieldPoint system you can save this configuration as the new power up state for the system A Right click the cFP 20xx controller in the left pane of FieldPoint Explorer and select Edit this device B Clear the factory configuration checkbox C Specify the power up settings with either of the following options f you want only the range and attribute settings you configured to be saved as power up states click OK These settings are writt
7. CP IP f Subnet Mask 255 255 0 0 e P Address The unique computer readable STEUN address of a device on your network An IP address Oo M is typically represented as four numbers separated by periods for example 130 164 55 112 where the Cancel Apply numbers can be between 0 and 255 inclusive e Subnet Mask A code that helps the network device determine whether another device is on the same subnet or a different subnet The most common subnet mask is 255 255 255 0 Gateway The IP address of a device that acts as a gateway server which is a connection between two networks e DNS Address The IP address of a network device that stores host names and translates them into IP addresses parameters to 0 0 0 0 H Enter values on the System tab of the System Configuration dialog box Host Name Can describe the physical location of the system or the application where it is being Network Settings System Servers used Device Information e Comment Helps to identify the controller epus puer cpm P Serial No FFFFFFFF e Password protect Resets Determines whether MAC Address 0080209503 users are allowed to reset the Compact FieldPoint Device Status Running system remotely If this checkbox is selected a user ee ere Beer must provide the password in order to reset the F t Password protect Resets system remotely You must disable resets from FieldPoint Explorer separately by setting user
8. FieldPoint cFP 20xx Quick Start Guide What You Need to Get Set Up e 0 module s e cFP 20xx LabVIEW RT controller Mounting hardware DIN rail panel mount or rack mount accessory Connectivity accessories connector blocks cables a Mount the Compact FieldPoint Backplane You can mount the cFP BP x backplane on a 35 mm DIN rail on a panel or in a standard 19 in rack Before using any of these mounting methods record the serial number from the back of the backplane 11 30 V power supply Accessories Ethernet cable screwdriver PC running Windows FieldPoint software 3 0 2 or later LabVIEW RT CAUTION Keep in mind these requirements for space and cabling clearance Allow at least 51 mm 2 in all around the backplane for air circulation Allow 38 mm 1 5 in below the controller for cabling clearance Min 182 mm 7 18 in 106 mm 4 18 in Cooling Outline 50 8 mm 2 00 in National Instruments Corporation 4 slots 246 mm 9 68 in 8 slots 441 mm 17 4 in Min 165 mm 6 50 in Cooling Outline 50 8 mm 2 00 in Hm gs 1 4 slots 246 mm 9 68 in lots 44 1 mm 17 4 in oo Cabling Cooling Outline Clearance 51 76 mm 2 3 in All Around cFP 20xx Quick Start Guide Mounting the Backplane on a DIN Rail A Fasten the DIN rail clip s to the cFP BP x using a number
9. ay 32 27 73 00 Polan Sloven Switze CVI 2 795 8248 For telephone support outside the United States contact your ria 0662 45 79 90 0 Belgium 02 757 00 20 Brazil 55 11 3262 3599 91 Canada Montreal 514 288 5722 Canada Ottawa 613 233 5949 3091 Japan 03 5472 2970 Korea 02 3451 3400 Malaysia 603 9596711 22 3390 150 Portuga 210 311 210 Russia 095 238 7139 Singapore 65 6 226 5886 ia 3 425 4200 South Africa 11 805 8197 Spain 91 640 0085 Sweden 08 587 895 00 rland 056 200 51 51 Taiwan 02 2528 7227 United Kingdom 01635 523545 FieldPoint LabVIEW Lookout Measurement Studio and ni com are trademarks of National Instruments Corporation Produc and company names companies mentioned herein are trademarks or trade names of their respective For patents covering National Instruments products refer to the appropriate location Help Patents in your so 2001 2002 National Instruments Corporation All rights reserved tware the patents txt file on your CD or ni com patents 323334A 01
10. d twisted pair Ethernet cable If the host PC is already configured on a network you must configure the cFP 20xx on the same network If neither is connected to a network you can connect the two directly using a crossover cable In order to configure the cFP 20xx it must reside on the same subnet as the host PC If you want to use the cFP 20xx on a subnet other than the one the host PC is on first connect and configure it on the same subnet as the host PC then reassign a static IP address for the subnet where you want it to be and physically move it to the other subnet e Wire Power to the Compact FieldPoint System Each cFP 20xx on your network requires an 11 30 VDC power supply A Connect the positive lead of the primary power supply to one of the V1 terminals and the negative lead to one of the C terminals 11 30 VDC Backup Power Supply optional E Q 11 30 VDC Primary Power Supply B If you are using a backup power supply connect the positive lead to V2 and the negative lead to one of the C terminals The cFP 20xx uses the power supply with the higher voltage level V2 is isolated from the other V terminals cFP 20xx Quick Start Guide 8 ni com C Use a separate power supply for each module that needs external power UN CAUTION Cascading power defeats isolation between the cascaded modules D Refer to the operating instructions for the power requirements of each O module If a module
11. en to the nonvolatile memory of the controller f you want to save power up values for the range and attribute settings and also all the current output states of the output channels click Snapshot This stores the current ranges attributes and output values of the bank to the nonvolatile memory of the network module Click OK when you are finished CAUTION Using the Snapshot feature overwrites any power up values you have specified for individual channels in the Channel Configuration dialog box Refer to the user manual for more information about configuring and changing the power up values and configuring a network watchdog to guard against network failures cFP 20xx Quick Start Guide 18 ni com NATIONAL INSTRUMENTS Go to ni com support for the most current manuals examples and troubleshooting information For telephone support in the United States create your service request at ni com ask and follow the calling local b United Austra instructions or dial 5 ranch office States 512 683 0100 lia 03 9879 5166 Aus Canada Calgary 403 274 93 Canada Qu bec 514 694 8521 Canada Toronto 905 785 0085 China 86 21 6555 7838 Czech Republic 02 2423 5774 Denmark 45 76 26 00 Finland 09 725 725 11 France 01 48 14 24 24 Germany 089 741 31 30 Greece 01 42 96 427 Hong Kong 2645 3186 India 91 80 4190000 Israel 03 6393737 Italy 02 4 Mexico 001 800 010 0793 Netherlands 0348 433466 New Zealand 09 914 0488 Norw
12. ents Corporation 9 cFP 20xx Quick Start Guide Install Software on the Host PC A Install the software packages you plan to use such as LabVIEW LabVIEW RT Lookout Measurement Studio or LabWindows CVI before you install the FieldPoint software The FieldPoint software installation installs the LabVIEW VIs and examples Lookout driver class and LabWindows CVI instrument driver only if it finds the corresponding development software installed B Close all other applications C Insert the FieldPoint software CD into the CD ROM drive on your computer D Follow the onscreen instructions to complete the installation NOTE f the setup does not launch automatica enter setup where d is the letter of your 9 Configure the cFP 20xx in FieldPoint Explorer If you do not have version 3 0 2 or later of FieldPoint Exp ni com and install it on the PC ly select Start Run from Windows CD ROM drive and select OK orer download the current version from A Verify that the Compact FieldPoint system is powered on B From the Windows Start menu select Programs National Instruments FieldPoint FieldPoint Explorer to launch FieldPoint Explorer shown in the following figure untitled FieldPoint Explorer OF x File DNH I O View Options Help gt FieldPoint IAK operation was successful cFP 20xx Quick Start Guide 10 ni com C Click the sign next to IA Server with OPC in the left pane t
13. k Start Guide Finding and Configuring Devices and Channels After you have configured the cFP 20xx in FieldPoint Explorer follow these steps to configure Compact FieldPoint devices and channels A In the Comm Resource Configuration dialog box click Find Devices to search for all of the devices connected to the cFP 20xx If the Comm Resource Configuration dialog box is not already open right click the cFP 20xx in FieldPoint Explorer and select Edit this comm resource If FieldPoint Explorer finds no devices refer to the user manual B After FieldPoint Explorer finds the Compact FieldPoint modules click the sign next to FP Res in the left pane to expand the device hierarchy and display the modules found on the network Process 1 FieldPoint Explorer of x File DNH I O View Options Help D cs g 2 E 1A Server with OPC B FieldPoint deh cFP 2020 0 0 cFP 2020 1 IAK operation was successful Hf FPRes Ghcrp po 401 1 FP DO 401 1 IAK operation was successful cFP 2020 0 Gherp al t 10 2 2 FP AI 110 1 IAK operation was successful B cFP DO 401 1 Shcrp ao 200 3 3 FP AO 200 1 TAK operation was successful Ge cFP AI 110 2 GherP ao 2100 4 4 FP AO 210 1 TAK operation was successful pagans Es GhcrP R1D 122 5 5 FP RTD 122 1 IAK operation was successful cFP RTD 122 5 Serp Tc 120 6 6 FP TC 120 1 TAK operation was successful cFP TC 120 6 Shcrp DI 301 7 7 FP DI 301 1 IAK operation was successful B cFP DI 301 7
14. nnect 1 0 modules to input signals or to external loads you need to install a cFP CB x connector block or other connectivity accessory for each 1 0 module on the backplane Use the connector socket to the right of each 1 0 module socket A Wire field devices as described in the 1 0 module CAUTION Hazardous operating instructions voltage wiring should be performed by qualified personnel and in accordance with local electrical standards B Align the captive screws on the connector block with the holes on the backplane C Press firmly to seat the connector block on the backplane D Using a number 2 Phillips screwdriver with a shank of at least 64 mm 2 5 in length tighten the captive screws to 1 1 N m 10 Ib in of torque E Repeat this procedure to install additional connector blocks on the backplane National Instruments Corporation 7 cFP 20xx Quick Start Guide Connect the cFP 20xx to Your Network Connect the cFP 20xx controller to an Ethernet network using the RJ 45 Ethernet port on the controller Use a standard Category 5 Ethernet cable to connect the cFP 20xx to an Ethernet hub or use an Ethernet crossover cable to connect the controller directly to a computer CAUTION To prevent data loss and to maintain the integrity of your Ethernet installation do not use a cable longer than 100 m If you are using a 100 Mbps Ethernet National Instruments recommends using a Category 5 shielde
15. o expand the view Right click FieldPoint and select Add a comm resource to this server The Configuration dia Comm Resource og box appears D Set the Type to Ethernet as shown in the following fi gure Each Ethernet comm resource represents a single FieldPoint networl module on Comm Resource Configuration x Name r FP Res atc r Attributes om or IP Address Browse Com Timeout msec pn o Timeout msec 2000 National Instruments Corporation 11 JUST Cancel the network Find Devices E Click Browse to launch Remote System Explorer Remote System Explorer searches for any cFP 20xx or other National Instruments Ethernet devices on the subnet lolx S Remote System Explorer Fie View Tools Help me ae alel see Seit lPAdkes Status Model Comment JM FFFFFFFF 0000 Uneonfigured cFP 2020 F Double click the serial number of the cFP 20xx you want to configure Alternatively you can right click the controller and choose Configure Device cFP 20xx Quick Start Guide G Enter values on the Network Settings tab of the System Configuration dialog box shown in the Network Seting System Server A TCPAP Settings figure at right If your network does not have a Sumsvaml Tibe gateway server or DNS server you should set those 7 Gbtam IP Address fiom DHCP Server F Hal device if T
Download Pdf Manuals
Related Search
Related Contents
初刷 差し替え箇所 ダウンロード Tableau Interactif Walk-and Tu equipo Manual de instrucciones del OmniTouch 4135 IP - Alcatel Frigidaire MWF-10304 Use and Care Manual "user manual" Samsung K5 1GB Benutzerhandbuch NanoDrop Spectrofluorometer V 2.5B User's Manual AGITADOR VERTICAL NHS Copyright © All rights reserved.