Napoleon Fireplaces GT8P User's Manual

image

Contents

1. FIGURE 2b LU MAXIMUM VERITICAL FIGURE 2c W415 0619 B 03 03 08 TYPICAL VENT INSTALLATIONS VERTICAL TERMINATION max FIGURE Pw Lue wap wa Vertical run when not venting horizontally 24 19 1 2 FT See graph to determine the required vertical rise VT for the required horizontal rise Hr REQUIRED VERTICAL RISE IN FEET V7 19 1 2 FT MAX 4 HORIZONTAL VENT RUN PLUS OFFSET IN FEET Hr d L MINIMUM 2 uf VERITICAL HORIZONTAL 4 VERTICAL IN MIN FIGURE 3a FIGURE 3b FIGURE 3c W415 0619 03 03 08 FIGURE 4 INSTALLATIONS CANADIAN U S A 12 INCHES 12 INCHES 12 INCHES 18 INCHES 12 INCHES 0 INCHES 0 INCHES 2 INCHES FEET 3FEET 12 INCHES 6FEET 7 FEETt 12 INCHESTT 16 INCHES 2 FEETt MINIMUM AIR TERNMINAL LOCATION CLEARANCES 12 INCHES 9 INCHES 12 INCHES 18 INCHES 12 INCHES 0 INCHES 0 INCHES 2 INCHES FEET 3FEET 9 INCHES FEETt 7 FEET
2. CAULKING WEATHER SEALANT FIREPLACE VENT CONNECTION 1 Install the 3 flexible vent pipe to the fireplace Secure with 3 22 screws and flat washers Seal the joint and screw holes using Mill CBA Pac sealant W573 0007 not supplied gt 2 Install the 5 flexible vent pipe to the fireplace Attach and seal the joints using the high temperature sealant W573 0002 not supplied FIGURE 15 MOBILE HOME INSTALLATION This appliance is certified to be installed as an OEM Original Equipment Manufacturer installation in a manufactured home or mobile home and must be installed in accordance with the manufacturer s instructions and the Manufactured Home Construction and Safety Standard Title 24 CFR Part 3280 in the United States or the Mobile Home Standard CAN CSA Z240 MH Series in Canada This appliance is only for use with the type s of gas indicated on the rating plate A conversion kit is supplied with the mobile home appliance This Mobile Manufactured Home Listed appliance comes factory equipped with a means to secure the unit The fireplace is equipped with two 1 4 diameter holes located in the front left and right corners of the base For mobile home installations the fireplace must be fastened in place Use 10 hex head screws inserted through the holes in the base to secure Always turn off the pilot and the fuel supply at the source prior to moving the mobile home After moving the mobile home and prior t
3. with respect to the NAPOLEON gas fireplace and any other warranties expressed or implied with respect to this product its components or accessories are excluded NAPOLEONC neither assumes nor authorizes any third party to assume on its behalf any other liabilities with respect to the sale of this product NAPOLEON will not be responsible for over firing downdrafts spillage caused by environmental conditions such as rooftops buildings nearby trees hills mountains inadequate vents or ventilation excessive venting configu rations insufficient makeup air or negative air pressures which may or may not be caused by mechanical systems such as exhaust fans furnaces clothes dryers etc Any damages to fireplace combustion chamber heat exchanger brass trim or other component due to water weather damage long periods of dampness condensation damaging chemicals or cleaners will not be the responsibility of NAPOLEON The bill of sale or copy will be required together with a serial number and a model number when making any warranty claims from your authorized dealer The warranty registration card must be returned within fourteen days to register the warranty NAPOLEON reserves the right to have its representative inspect any product or part thereof prior to honouring any warranty claim ALL SPECIFICATIONS AND DESIGNS ARE SUBJECT TO CHANGE WITHOUT PRIOR NOTICE DUE TO ON GOING PRODUCT IMPROVEMENTS NAPOLEON IS AREGISTERED TRADEM
4. 12 INCHES 16 INCHES 2 FEETt Clearance above grade veranda porch deck or balcony Clearance to windows or doors that open Clearance to permanently closed windows Vertical clearance to ventilated soffit located above the terminal within a horizontal distance of 2 feet from the centerline of the terminal Clearance to unventilated soffit Clearance to an outside corner wall Clearance to an inside non combustible corner wall or protruding non combustible obstructions chimney etc Clearance to an inside combustible corner wall or protruding com bustible obstructions vent chase etc Clearance to each side of the centerline extended above the meter regulator assembly to a maximum vertical distance of 15ft Clearance to a service regulator vent outlet Clearance to a non mechanical air supply inlet to the building or a combustion air inlet to any other appliance Clearance to a mechanical air supply inlet Clearance above a paved sidewalk or paved driveway located on public property unless fitted with a heat shield kit GD 301 Clearance under a veranda porch deck or balcony Clearance above the roof Clearance from an adjacent wall including neighbouring buildings Recommended to prevent condensation on windows and thermal breakage It is recommended to use a heat shield and to maximize the distance to vinyl clad soffits This is a recommended distance For additional requireme
5. PRESSURE 3 Pressure can be adjusted by removing cap B using a flat screwdriver and adjusting the nylon plug with the same screw driver Turning the plug in clockwise will increase the pressure NATURAL GAS Se CERAMIC HIGH VOLTAGE 777 IGNITION CABLE a FIGURE 34 VENTURI ADJUSTMENT Closing the air shutter will cause a more yellow flame but can lead to carboning Opening the air shutter will cause a more blue flame but can cause flame lifting from the burner ports The flame may not appear yellow immediately allow 15 to 30 minutes for the final flame color to be established NOTE It is important that PAE a eo M att ers the venturi sits down tight on the orifice The burner 5 16 DIA x2 is adjustable up down to 3 16 DIA x1 ensure this FIGURE 35 VENTURI BURNER AIR SHUTTER OPENING ORIFICE FLAME CHARACTERISTICS It is important to periodically perform a visual check of the burner flame Compare them to the illustration provided FIGURE 36 W415 0619 B 03 03 08 N 0 REPLACEMEN Contact your dealer for questions concerning prices and availability of replacement parts Normally all parts can be ordered through your Napoleon dealer or distributor When ordering replacement parts always give the following information MODEL amp SERIAL NUMBER OF FIREPLACE INSTALLATIO
6. 5 flexible vent pipe HORIZONTAL AIR TERMINAL INSTALLATION 1 Stretch the 3 flexible vent pipe to the required length taking into account the additional length needed for the finished wall surface Apply a heavy bead of the high temperature sealant W573 0007 not supplied Slip the flexible vent pipe a minimum of 2 over the inner sleeve of the air terminal and secure with 3 8 screws NOTE If using pipe clamps to connect vent components 3 screws must also be used to ensure the connection cannot slip off HIGH TEMPERATURE SEALANT 2 Using the 5 flexible vent pipe slide over the outer combustion EXTERIOR air sleeve of the air terminal and secure with 3 8 screws Seal GD179 WALL using high temperature sealant W573 0002 not supplied EIGURE 10 3 Insert the flexible vent pipe through the firestop maintaining the required clearance to combustibles Secure the terminal to the 7 exterior wall lettering in an upright readable position make FLEXIBL 3 FLEXIBLE VENT PIPE AGF 5 COUPLER weather tight by sealing with caulking not supplied VENT UH 4 If additional flexible vent pipe is required couple them together SS d 5 FLEXIBLE as illustrated The vent system must be supported approximately aI VENT PIPE every 3 feet for both vertical and horizontal runs Use non FIGURE 18 COUPLER combustible strapping to maintain the minimum 1 clearance to HI
7. TRIM BRACKET 17 ACCENT GLASS INSTALLATION Carefully sprinkle the accent glass onto the glass support evenly Ensure no glass falls into the burner area If this happens insert a clean bag into your vacuum cleaner and BURNER vacuum out the accent glass Replacement accent glass can be purchased from Wolf Steel Ltd FIGURE 30 1 Turn off the electrical and gas supply to the fireplace 2 Remove the frame from the unit by removing the 2 black securing screws from the top and the 2 silver hex head securing screws from the bottom 3 Lay the frame down on its front being careful not to scratch the finish 4 Starting at the top of the frame take one light assembly and carefully snap it into place in the hole provided Repeat for each of the light assemblies The wires on the top 2 light assemblies will need to be fed in behind the heat shields Note When installing the light kit be careful not to scratch your fingers on any of the exposed screws in the frame 5 Using Figure 31 as a guide connect the light assemblies to the appropriate flags on the wire harness The wire harness is labeled TR top right BR bottom right TL Top left and BL bottom left 6 Secure the wires into the clips at both sides and the bottom of the frame Use the extra clips provided to retain any loose wires 7 Re attach frame onto unit 8 Remove the control panel by removing the 2 screws securing it along the top edge Leav
8. first year Repair work however requires the prior approval of an authorized company official Labour costs to the account of NAPOLEON ave based ona predetermined rate schedule and any repair work must be done through an authorized NAPOLEON dealer CONDITIONS AND LIMITATIONS NAPOLEON warrants its products against manufacturing defects to the original purchaser only i e the individual or legal entity registered customer whose name appears on the warranty registration card filed with NAPOLEON provided that the purchase was made through an authorized NAPOLEON dealer andis subject to the following conditions and limitations This factory warranty is nontransferable and may not be extended whatsoever by any of our representatives The gas fireplace must be installed by a licenced authorized service technician or contractor Installation must be done in accordance with the installation instructions included with the product and all local and national building and fire codes This limited warranty does not cover damages caused by misuse lack of maintenance accident alterations abuse or neglect and parts installed from other manufacturers will nullify this warranty This limited warranty further does not cover any scratches dents corrosion or discolouring caused by excessive heat abrasive and chemical cleaners nor chipping on porcelain enamel parts mechanical breakage of PHAZER logs and embers nor any venting co
9. instructions To Turn Off Gas and call your service technician or gas supplier TIU 557 Tar FIGURE 32 C9 EM MANUAL SHUT OFF SHOWN IN OFF POSITION TO TURN OFF GAS 1 Turn the fireplace switch to the OFF position 2 Turn off all electrical power to the fireplace if service is to be preformed 3 Turn manual shut off valve clockwise to off Do not force RATING PLATE RATING LABEL LOCATION The rating label is located under the control panel and is chained to the fireplace DO NOT REMOVE WERTE CERTIFIED UNDER CSA 2 22 2007 ANSI 21 50 2007 VENTED GAS FIREPLACE DIRECT VENT GAS FIREPLACE APPROVED FOR BEDROOM BATHROOM AND BED SITTING ROOM INSTALLATION ES cV 05 we 15901 ANSINEPA 501A MODEL GT8N NATURAL GAS 0 4500FT 0 1370m 6 000 BTU h CERTIFIED FOR CANADA AND USA ALTITUDE INPUT SUITABLE FOR MOBILE HOME INSTALLATION IF INSTALLED INACCORDANCE WITH THE CURRENT STANDARD CAN CSA Z240MH SERIES GAS EQUIPPED MOBILE HOMES IN CANADA OR IN THE UNITED STATES THE MANUFACTURED HOME CONSTRUCTION AND SAFETY STANDARD TITLE 24 DFR PART 3280 WHEN THIS US STANDARD IS NOT APPLICABLE USE THE STANDARD FOR FIRE SAFETY CRITERIA FOR MANUFACTURED HOME INSTALLATIONS SITES AND COMMUNITIES MODEL E GT8P PROPANE 0 4500FT 0 1370m 6 000 BTU h 56 ORIFICE 69 MANIFOLD PRESSURE 3 5 WAT
10. or the maximum vertical vent length can create difficulty in burner start up and or carboning Under extreme vent configurations allow several minutes 5 15 for the flame to stabilize after ignition Vent lengths that pass through unheated spaces attics garages crawl spaces should be insulated with the insulation wrapped in a protective sleeve to minimize condensation Provide a means for visually checking the vent connection to the fireplace after the fireplace is installed Use firestop spacer W500 0358 when penetrating interior walls and ceilings HORIZONTAL VENT SECTIONS A minimum clearance of 1 at the bottom sides and top of the vent pipe in all horizontal runs to combustibles is required Use firestop spacer W500 0358 supplied VERTICAL VENT SECTIONS A minimum of 1 all around the vent pipe on all vertical runs to combustibles is required Use firestop spacer W500 0358 not supplied W415 0619 B 03 03 08 TYPICAL VENT INSTALLATIONS HORIZONTAL TERMINATION Vertical run Immediately off the fireplace if 7 FT maximum horizontal run is required See graph to determine the required vertical rise Vr for the required horizontal rise Hr 10 9 REQUIRED VERTICAL RISE IN FEET V7 1 2 3 4 5 6 7 8 9 10 HORIZONTAL VENT RUN PLUS OFFSET IN FEET Hr MAXIMUM FIGURE 2a HORIZONTAL 4 MIN 24 MAX
11. 0 0134 STORM COLLAR W415 0619 B 03 03 08 21 TROUBLE SHOOTING GUIDE SYMPTOM PROBLEM TEST SOLUTION Electrode sparks burner Hot and neutral wires are reversed Connect the hot wire to the black wire Connect the neutral wire to ignites electrode at control module the white wire continues to spark for complete 7 seconds Sensor flame not connecting Raise electrode sensor up into flame burner shuts down Main burner flame is a blue lazy transparent Blockage in vent flame Remove blockage In extremely cold conditions ice buildup may occur on the terminal and should be removed as required Flame length Unit is over fired or under fired Check pressure readings consistently too large Outlet pressure can be checked by removing cap A and replacing or too small Carboning it with a 1 8 barb fitting Next place pressure gauge tubing Occurs over the fitting Gauge should read 3 5 W C for natural gas or Y 10 0 W C for propane AFTER TAKING PRESSURE READINGS BE SURE TO REPLACE CAP TO RESEAL DO NOT OVER TORQUE Leak test with a soap and water solution Air shutter has become blocked Ensure air shutter opening is free of lint or other obstructions Open air shutter to increase the primary air Check the input rate check the manifold pressure and orifice size as Carbon is being specified by the rating plate values deposited on glass logs Check th
12. ARK OF WOLF STEEL LTD PATENTS U S 5 303 693 801 CAN 2 073 411 2 082 915 WOLF STEEL LTD W415 0619 B 03 03 08 GENERAL INSTRUCTIONS THIS GAS FIREPLACE SHOULD BE INSTALLED AND SERVICED BY A QUALIFIED INSTALLER to conform with local codes Installation practices vary from region to region and it is important to know the specifics that apply to your area for example in Massachusetts State The fireplace damper must be removed or welded in the open position prior to installation of a fireplace insert or gas log Acarbon monoxide detector is required in all rooms containing gas fired appliances The appliance off valve must be a T handle gas cock The flexible connector must not be longer than 36 inches The appliance is not approved for installation in a bedroom or bathroom unless the unit is a direct vent sealed combustion product WARNING This product must be installed by a licensed plumber or gas fitter when installed in the Commonwealth of Massachusetts In absence of local codes install to the current CAN CGA B149 Installation Code in Canada or to the National Fuel Gas Code ANSI Z223 1 and NFPA 54 in the United States Suitable for mobile home installation if installed in accordance with the current standard CAN CSA Z240MH Series for gas equipped mobile homes in Canada or ANSI Z223 1 and NFPA 54 in the United States The fireplace and its individual shutoff valve must be disconnected from NATIONAL the g
13. ER COLUMN MANIFOLD PRESSURE 10 WATER COLUMN MINIMUM SUPPLY PRESSURE 4 5 WATER COLUMN MINIMUM SUPPLY PRESSURE 11 WATER COLUMN MAXIMUM SUPPLY PRESSURE 7 0 WATER COLUMN MAXIMUM SUPPLY PRESSURE 13 WATER COLUMN WARNING NOT ADD ANY MATERIAL TO THE APPLIANCE WHICH WILL COME IN CONTACT WITH THE FLAMES OTHER THAN THAT SUPPLIED BY THE MANUFACTURER WITH THE APPLIANCE MINIMUM CLEARANCES TO COMBUSTIBLE MATERIALS TOP 6 RECESSED DEPTH T FLOOR 0 VENT 1 SIDES 0 BACK 11 2 TOP SIDES amp BACK AS PER ABOVE FOR FINISHING MATERIAL SEE OWNERS MANUAL VENTED GAS FIREPLACE NOT FOR USE WITH SOLID FUEL FOR USE WITH GLASS DOOR CERTIFIED WITH THIS UNIT ONLY THE APPLIANCE MUST BE VENTED USING THE APPROPRIATE NAPOLEON VENT KITS SEE OWNERS INSTALLATION MANUAL FOR VENTING SPECIFICS PROPER REINSTALLATION AND RESEALING IS NECESSARY AFTER SERVICING THE VENT AIR INTAKE SYSTEM THIS APPLIANCE IS ONLY FOR USE WITH THE TYPE OF GAS INDICATED ON THE RATING PLATE AND MY BE INSTALLED IN AN AFTERMARKET PERMANENTLY LOCATED MANUFACTURED HOME USA ONLY OR MOBILE HOME WHERE NOT PROHIBITED BY LOCAL CODES SEE OWNER S MANUAL FOR DETAILS THIS APPLIANCE IS NOT CONVERTIBLE FOR USE WITH OTHER GASES UNLESS A ELECTRICAL RATING 115v 0 82AMP 60HZ MINIMUM AND MAXIMUM HORIZONTAL VENT LENGTHS ARE 10 INCHES AND 10 FEET RESPECTIVELY O MINIMUM AND MAXIMUM VERTICAL VENT LENGTHS ARE 36 INCHES AND 10 FEET RESPECTIVELY W415 0619 B 03 03 08 C
14. ERTIFIED KIT IS USED MADE IN CANADA WOLF STEEL LTD BARRIE ON CANADA SERIAL NUMBER W385 0381 A 19 MAINTENANCE TURN OFF THE GAS AND ELECTRICAL POWER BEFORE SERVICING THE FIREPLACE CAUTION Label all wires prior to disconnection when servicing controls Wiring errors can cause improper and dangerous operation Verify proper operation after servicing This fireplace and its venting system should be inspected before use and at least annually by a qualified service person The fireplace area must be kept clear and free of combustible materials gasoline or other flammable vapours and liquids The flow of combustion and ventilation air must not be obstructed 1 Keep the control compartment burner and air shutter opening clean by vacuuming or brushing at least once a year 2 Check to see that the main burner ignites when the switch for the burner is turned on A 5 second light up period is satis factory If ignition takes longer consult your Napoleon dealer distributor 3 Check that the gasketing on the sides top and bottom of the door is not broken or missing Replace if necessary ADJUSTMENTS GAS PRESSURE ADJUSTMENT Outlet pressure can be adjusted if not measuring 3 5 W C NG or 10 0 W C LP 18 FIGURE 33 NPT BARB 1 Pressure can be checked by removing cap A using a 3 16 allen key and replacing it with a 1 8 NPT barb fitting 2 Place pressure gauge tube over the fitting
15. GH TEMPERATURE combustibles from the flexible vent pipe SEALANT VERTICAL AIR TERMINAL INSTALLATION 1 Fasten the roof support to the roof using the screws provided The roof support is optional In this case the DIBER venting is to be adequately supported using either an alternate method suitable to the authority having jurisdiction or the optional roof support Figure 12 FIGURE 13 2 Stretch the 3 flex vent pipe to the required length ini TERMINAL Slip the 3 flex vent pipe a minimum of 2 over the inner CONNECTOR pipe of the air terminal connector and secure with 3 8 4 screws Seal using a heavy bead of high temperature HIGH sealant W573 0007 not supplied Figure 13 ROOF SUPPORT SX TENPERAT RE NOTE If using pipe clamps to connect vent SEALANT components 3 screws must also be used to ensure the connection cannot slip off 3 FLEXIBLE 3 Repeat using the 5 flex vent pipe using a heavy bead of high temperature sealant VENT PIPE W573 0002 not supplied Figure 13 S FLEXIBLE W415 0619 B 03 03 08 12 4 Thread the air terminal connector vent pipe assembly down through the roof The air terminal must be located vertically and plumb Attach the air terminal connector to the roof support ensuring that the top of the air terminal is 16 above the highest point that it penetrates the roof Figure 12 DO NOT CLAMP THE FLEX VENT PIPE 5 Remove nails from the shingles abov
16. INSTALLER LEAVE THIS MANUAL WITH THE APPLIANCE CONSUMER RETAIN THIS MANUAL FOR FUTURE REFERENCE a EE INSTALLATION AND quacryrnercaces OPERATION INSTRUCTIONS Award Winning Products CERTIFIED UNDER CANADIAN AND AMERICAN NATIONAL STANDARDS CSA 2 22 ANSI Z21 50 FOR VENTED GAS FIREPLACE TORCH GT8N NATURAL GAS GT8P PROPANE Certified for Canadian and United States using ANSI CSA Methods SAFETY INFORMATION If the information in these instructions are not followed exactly a fire or explosion may result causing property damage personal injury or loss of life Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance WHAT TO DO IF YOU SMELL GAS e Do not try to light any appliance e Do not touch any electrical switch do not use any phone in your building e Immediately call your gas supplier from a HPBA neighbour s phone Follow the gas supplier s musio instructions e f you cannot reach your gas supplier call the fire department Installation and service must be performed by a qualified installer service agency or the supplier Z GREN TERTE D m Lax Quality System Certified To 4 cV Noy 9001 2000 rocca APPLY SERIAL RTON 000000 MODEL NO Wolf Steel Ltd 24 Napoleon Rd Barrie ON LAM 4Y8 Canada 705 721 1212 fax 705 722 6031 UMBER
17. LABEL FROM CA Serial No www napoleonfireplaces com ask napoleon on ca 10 00 W415 0619 B 03 03 08 2 TABLE of CONTENTS PG 2 5 INTRODUCTION 15 17 FINISHING Warranty Door Removal General Instructions Glass Removal General Information Frame Front Installation Care of Glass and Plated Parts Accent Glass Installation Dimensions LK8 Light Installation Optional 5 10 VENTING 18 OPERATING INSTRUCTIONS Venting Lengths and Air Terminal Locations Vent Installations 1 9 MAINTE NANCE Typical Vent Installations Horizontal Termination Typical Vent Installations Vertical Termination 1 9 ADJUSTMENTS Minimum Air Terminal Location Clearances Gas Pressure Adjustment Venting Application Flow Chart Venturi Adjustment Flame Characteristics 10 15 INSTALLATION FRAMING Wall and Ceiling Protection 20 REPLACEM ENTS Vertical Installation Replacement Parts Using Flexible Vent Components Flexible Vent Kits Horizontal Air Terminal Installation Terminal Kits Vertical Air Terminal Installation Accessories Fireplace Vent Connection Mobile Home Installation Gas Installation Electrical Connection Stand off Assembly Nailing Tab Installation Framing Clearance to Combustibles This appliance may be installed as an OEM installation in a manufactured home USA only or mobile home and must be installed in accordance with the manufacturers instructions and the Manufactured Home Construction and Safety Standard Title 24 CFR Pa
18. N DATE OF FIREPLACE PART NUMBER DESCRIPTION OF PART FINISH ORWON gt REPLACEMENT PARTS PART NO DESCRIPTION 1 W225 0216 DOOR FRAME 2 W562 0008 DOOR GASKET 3 W010 1736 DOOR LATCH ASSEMBLY 4 W010 1743 GLASS c w GASKET 5 W300 0088 GLASS 6 W100 0104 BURNER W357 0006 GNITOR 8 W190 0026 CONTROL MODULE 9 W750 0183 10 W750 0184 11 W200 0234 12 W200 0233 13 W725 0052 13 W725 0053 14 1455 0085 14 1455 0086 WIRE HARNESS GNITION CABLE GNITOR COVER BURNER COVER NATURAL GAS VALVE 3 5 W C PROPANE GAS VALVE 10 0 W C NATURAL GAS ORIFICE PROPANE GAS ORIFICE 15 W500 0358 FIRESTOP SPACER 16 W475 0522 BACK PANEL 17 W300 0108 ACCENT GLASS BLACK 18 W385 0334 NAPOLEON LOGO 19 W290 0123 EXHAUST GASKET 20 W290 0125 BURNER GASKET 21 W562 0046 ROPE GASKET BACK PANEL 22 TFK TORCH FRAME PAINTED METAILIC BLACK FINISH 22 TFR TORCH FRAME RED FINISH 22 TFP TORCH FRAME PEWTER FINISH 22 TFW TORCH FRAME wHITE FINISH 22 TFB TORCH FRAME sTEEL BLUE FINISH FLEXIBLE VENT KITS GDT5 5 FT 23 1730 0031 24 WT30 0032 25 W615 0080 GDT10 10 FT 26 W730 0033 27 WT30 0034 25 W615 0080 3 FLEXIBLE VENT PIPE 5 rr 5 FLEXIBLE VENT PIPE 5 rr SPACERS 3 iNcLUDED 3 FLEXIBLE VENT PIPE 10 5 FLEXIBLE VENT PIPE 10 rr SPACERS 6 iNcLUbED TERMINAL KITS GD178 WALL TERMINAL KIT 28 WO010 1744 12 FLEXIBLE
19. OMBUSTIBLE NON COMBUSTIBLE rear and sides B c Vent pipe a4 BRICK Recessed depth 7 A E 12 MIN TO amp 6 COMBUSTIBLES AL MIN FA to ceiling or mantle TORCH B _Y FRAME E e NON COMBUSTIBLE pes FINISHING IS USED Y me SUCH AS BRICK AN cus STONE 1 Any protruding finishing material installed in this gt 1 1 2 MIN space ie baseboards must leave 2 of CONTROL DOOR unobstructed clearance to 4 OPEN POSITION o d allow for full rotation of the control door L S DM d FIGURE 23 L WITHOUT TORCH FRAME INSTALLED WITH TORCH FRAME INSTALLED DOOR REMOVAL Before the glass door can be removed the optional frame CLOSED OPEN front must be removed FIGURE 24 The glass door is secured to the top front edge of the firebox Pull the handles of the latches forward then lift the hooks out from the slots in the door frame to release the top of the door Then pivot forward until the top edge of the door clears the front of the fireplace Next gripping the sides of the door lift the door out from the retainer along the bottom of the door GLASS REMOVAL Having removed the door lay on a smooth flat surface face down There are 4 glass retainers that need to be bent away from the glass to release it from the frame Do not pry on GLASS the glass When replacing DO NOT SUBSTITUTE MATERIAL replace the gasket W562 0008 and the glass W300 0088 Set GA
20. SKET new glass into the frame and gently bend tabs into the gasket to secure NOTE Care must be taken when removing and disposing m of any broken glass or damaged components Be sure to GLASS vacuum up any broken glass from inside the fireplace before RETAINERS operation FIGURE 25 Lec W415 0619 B 03 03 08 16 FRAME FRONT INSTALLATION 1 Align the two holes in the upper portion of the hinge on the control door to those in the bottom trim bracket secure using two of the 8 x 1 2 hex head screws supplied Figure 26 2 Install the top trim bracket to the firebox using the three 9 14 x 1 2 hex head screws supplied in the TORCH manual baggie 3 Rest the top lip of the TORCH frame on the top trim bracket and the securing tabs at the bottom of the TORCH frame on the bottom trim bracket 4 Align the two slots in the top of the TORCH frame with the two holes in the FIGURE 26 top trim bracket and secure using the two 10 pan head screws supplied however TORCH do not fully tighten to leave room for adjustment Figure 27 5 Align the holes in the securing tabs at the bottom of the TORCH frame with the holes in the bottom trim bracket and secure using the two remaining 8 x 1 2 hex head screws however do not fully tighten to leave room for adjustment Figure 27 6 If required the bottom trim bracket can be ad
21. VENT ASSEMBLY 29 670 0010 3 5 FLEXIBLE HORIZONTAL TERMINAL GD179 TERMINAL ONLY 29 670 0010 3 5 FLEXIBLE HORIZONTAL TERMINAL ROOF TERMINAL KITS Failure to position the parts in accordance with these diagrams or failure to use only parts specified approved with this appliance may result in property damage or personal injury FOR WARRANTY REPLACEMENT PARTS A PHOTOCOPY OF THE ORIGINAL INVOICE WILL BE REQUIRED TO HONOUR THE CLAIM IDENTIFIES ITEMS WHICH ARE NOT ILLUSTRATED FOR FURTHER INFORMATION CONTACT YOUR NAPOLEON DEALER 35 W573 0002 HIGH TEMPERATURE SEALANT 35 W573 0007 HIGH TEMPERATURE SEALANT 36 W175 0204 3 COUPLER 37 W175 0166 5 COUPLER 38 W175 0270 CONVERSION KIT NG To LP 39 W175 0274 CONVERSION KIT LP To NG 40 W175 0271 COUPLER KIT 41 LK8 LIGHT KIT 42 AVS35KT VENT SLEEVE ASSEMBLY GDT113 30 W670 0011 AIR TERMINAL 31 1490 0076 3 5 INNER OUTER SLEEVE GDT110 1 12 7 12 PITCH 30 W670 0011 AIR TERMINAL 31 1490 0076 3 5 INNER OUTER SLEEVE 32 W010 1844 ROOF SUPPORT 33 W263 0099 ROOF FLASHING 34 1170 0134 STORM COLLAR GDT111 8 12 12 12 PITCH 30 W670 0011 AIR TERMINAL 31 W490 0076 3 5 INNER OUTER SLEEVE 32 W010 1844 ROOF SUPPORT 33 W263 0100 ROOF FLASHING 34 1170 0134 STORM COLLAR GDT112 FLAT ROOF 30 W670 0011 AIR TERMINAL 31 1490 0076 3 5 INNER OUTER SLEEVE 32 WO010 1844 ROOF SUPPORT 33 W263 0101 ROOF FLASHING 34 W17
22. aner Thereafter clean as required DO NOT CLEAN GLASS NEVER ALLOW CHILDREN WHEN HOT Do not use abrasive cleaners to clean plated parts Buff lightly TO TOUCH GLASS with a clean dry cloth If the glass is not kept clean permanent discolouration and or blemishes may result DIMENSIONS FIGURES 1a c L ELECTRICAL N GAS LINE ACCESS ACCESS VENTING VENTING LENGTHS AND AIR TERMINAL LOCATIONS The vent connection to the fireplace can be viewed by removing the baffle from the top inside of the firebox Use only Wolf Steel venting components Minimum and maximum vent lengths for both horizontal and vertical installations and air terminal locations for either system are set out in this manual and must be adhered to Use only Wolf Steel Ltd flexible vent components with the Wolf Steel Ltd GD179 termination kit This fireplace uses a 3 exhaust and a 5 instake diameter coaxil vent system All outer pipe joints of these venting systems must be sealed using Red RTV and or Mill Pac high temperature sealant not supplied hereafter referred to as high temperature sealant W573 0002 Red RTV and the high temperature sealant W573 0007 Mill Pac For vent systems that provide seals on the inner exhaust flue only the outer air intake joints must be sealed using a red high temperature silicone RTV This same sealant may be used on both the inner
23. as supply piping system during any pressure testing of that system FIREPLACE We suggest thar ee at test pressures in excess of 1 2 psig 3 5 kPa The fireplace must hearth products be installed be isolated from the gas supply piping system by closing its individual serviced by profes manual shutoff valve during any pressure testing of the gas supply piping sionals who are certified in system at test pressures equal to or less than 1 2 psig 3 5 kPa the U S by the National When the fireplace is installed directly on carpeting vinyl tile or other Fireplace Institute NFI as combustible material other than wood flooring the fireplace shall be CERTIFIED NFI Gas Specialists installed on a metal or wood panel extending the full width and depth www nficertified org GENERAL INFORMATION FOR YOUR SATISFACTION THIS FIREPLACE HAS BEEN TEST FIRED TO ASSURE ITS OPERATION AND QUALITY RATES AND EFFICIENCIES NATURAL GAS PROPANE GAS Altitude 0 4 500 0 4 500 Maximum Input 6 000 6 000 Maximum Output 4 680 Efficiency 78 Minimum Inlet Gas Suppy Pressure 11 Water Column Maximum Inlet Gas Supply Pressure 13 Water Column Manifold Pressure Under Flow Conditions 10 Water Column When the fireplace is installed at elevations above 4 500ft and in the absence of specific recommendations from the local authority having jurisdiction the certified high altitude input rating shall be reduced at the rate of 4 for each additio
24. at the door gasketing is not broken or missing and that the or combustion chamber Flame is impinging on the surfaces combustion chamber seal is tight Check that both 3 and 5 vent liners are free of holes and well sealed at all joints Check that the minimum rise per foot has been adhered to for any horizontal venting Sulphur from fuel is being Clean the glass with a gas fireplace glass cleaner DO NOT CLEAN White grey film forms deposited on glass logs or GLASS WHEN HOT If deposits not cleaned off regularly the combustion chamber surfaces glass may become permanently marked Check door seal Exhaust fumes smelled in Fireplace is spilling Check pressure relief device room headaches Check for chimney blockage Ensure that the paint curing process is complete m Connect jumper wire across the wall switch terminals if main Switch is defective burner lights replace switch thermostat No gas to the main Burner orifice is blocked Remove stoppage in orifice burner switch is on Check that the manual valve is turned on Burner will not light No gas at the burner Replace the valve ignitor sparks Out of propane gas Fill the tank Ignitor SENSOR Check the power source ie fuse circuit breaker will S Check that the wire is connected to both the ignitor and the control not module spark Check that the spark is not jumping to ignitor cover Replac
25. e and to the sides of the chimney Place the flashing over the air terminal connector leaving a min 3 4 ofthe air terminal connector showing above the top ofthe flashing Slide the flashing underneath the sides and upper edge of the shingles Ensure that the air terminal connector is properly centred within the flashing giving a 3 4 margin all around Fasten to the roof Do not nail through the lower portion of the flashing Make weather tight by sealing FIGURE 14 with caulking Where possible cover the sides and top edges of the flashing with roofing material Figure 14 6 Aligning the seams of the terminal and air terminal connector place the terminal a AIR INLET over the air terminal connector making sure the vent pipe goes into the hole in the BASE terminal Secure with the three screws provided Figure 14 7 Apply a heavy bead of weatherproof caulking 2 above the flashing Note Maintain a minimum 2 space between the air inlet base and the storm collar Install the storm collar around the air terminal and slide down to the caulking Tighten to ensure that a weather tight seal between the air terminal and the collar is achieved Figure 14 8 If more vent pipe needs to be used to reach the fireplace couple them together as illustrated The vent system must be supported approximately every 3 feet for both vertical and horizontal runs Use noncombustible strapping to maintain the minimum 1 clearance to combustibles Figure 11
26. e the wire if the wire insulation is broken or frayed rt Replace the electrode if the ceramic insulator is cracked or broken VOLTAGE 77 y ONION Spark gap is incorrect Spark gap should be 0 125 1 8 approx from the electrode tip to the CABLE sensor tip Remote wall switch is in Wall switch is mounted upside i a ae Reverse OFF position burner down Remote walls teh Wiis Check for ground short repair ground or replace wire grounding No spark at ignitor W415 0619 B 03 03 08 22 SNH3ONOO TVI23dS 39NVIWHOH 3d ADIANAS 3INVN NVISINHOAL 32IAH3S uo Ajjenuue padiases aq 15 E700 3 e 3 SIUL AJO JSIH BDIAIOS 4 19215 aiy AINVN W415 0619 B 03 03 08
27. e the wires connected to the ON OFF switch 9 Place the transformer into the bottom of the unit Plug the transformer into the receptacle 10 Lay the control panel flat along the bottom edge of the frame Attach one of the wire leads from the transformer to the lead on the wire harness labeled TRANS and the other to the ON OFF switch Attach the last lead on the wire harness labeled SWI to the ON OFF switch 11 Re secure the control panel 12 Turn on the gas supply and electrical power LK8 LIGHT INSTALLATION OPTIONAL FIGURE 31 W415 0619 B 03 03 08 18 OPERATING INSTRUCTIONS When lit for the first time the fireplace will emit a slight odour for a few hours This is a normal temporary condition caused by the curing of paints and lubricants used in the manufacturing process and will not occur again Simply open a window to sufficiently ventilate the room After extended periods of non operation such as following a vacation or a warm weather season the fireplace may emit a FOR YOUR SAFETY READ BEFORE LIGHTING A This fireplace is equipped with an ignition device which automatically lights the burner Do not try to light by hand B Before operating smell all around the fireplace area for gas and next to the floor because some gas is heavier than air and will settle on the floor C Do not use this fireplace if any part has been under water Im
28. ed Frame to local building codes To install the fireplace face flush with the finished surface position the framework to accommodate the thickness of the finished surface Use 4 flat head screws to secure the nailing tabs to the framing Cover the nailing tabs with your finishing material NOTE In order to avoid the possibility of exposed insulation or vapour barrier coming in contact with the fireplace body itis recommended that the walls of the fireplace enclosure be finished ie drywall sheetrock as you would finish any other outside wall of a home This will ensure that clearance to combustibles is maintained within the cavity 1 L 1 FIGURES 22a b amp c 44 11 INTERIOR BUILD OUT OUTSIDE 7 EXTERIOR CHASE E Eo 7 MIN SSe ne hea to INSIDE CHASE IX SIDE PROTBUSI N WALL FRAMING INSTALLATION FINISHING 4 OPENING DIMENSIONS OPENING DIMENSIONS NOTE Finished opening is smaller than the framed opening W415 0619 03 03 08 15 CLEARANCES TO COMBUSTIBLES Minimum clearance to combustible construction from fireplace and vent surfaces Fireplace framing 6 to top 0 to stand offs C
29. ertified with the unit are to be installed on the appliance W415 0619 B 03 03 08 NOTE Changes other than editorial are denoted by a line in the margin NAPOLEON products are manufactured under the strict Standard of the world recognized ZSO 9001 2000 Quality Assurance Certificate NAPOLEON products are designed with superior components and materials assembled by trained craftsmen who take great pride in their work The burner and valve assembly are leak and test fired at a quality test station The complete fireplace 1 again thoroughly inspected by a qualified technician before packaging to ensure that you the customer receives the quality product that you expect from NAPOLEON NAPOLEON GAS FIREPLACE PRESIDENT S LIFETIME LIMITED WARRANTY The following materials and workmanship in your new NAPOLEON gas fireplace are warranted against defects for as long as you oww the fireplace This covers combustion chamber heat exchanger stainless steel burner gold plated parts against tarnishing porcelainized enameled components and aluminum extrusion trims Electrical 110V and millivolt components and wearable parts such as blowers gas valves thermal switch switches wiring remote controls ignitor gasketing and pilot assembly are covered and NAPOLEON will provide replacement parts free of charge during the first year of the limited warranty Labour related to warranty repair is covered free of charge during the
30. exhaust and outer intake vent pipe joints of all other approved vent systems except for the exhaust vent pipe connection to the fireplace flue collar which must be sealed using the black high temperature sealant Mill Pac With flexible venting in conjunction with the GD178 wall terminal kit use either the 5 foot vent kit GDT5 or the 10 foot vent kitGDT10 These kits allow for extended horizontal venting of the fireplace When using approved Wolf Steel venting components use only the following termination kits WALL TERMINAL KIT GD178 or 1 12 TO 7 12 PITCH ROOF TERMINAL KIT GDT110 8 12 TO 12 12 ROOF TERMINAL KIT GDT111 FLAT ROOF TERMINAL KIT GDT112 Rigid and flexible venting systems must not be combined Wolf Steel and Simpson Dura Vent venting systems must not be combined Venting terminals shall not be recessed into a wall or siding For optimum flame appearance and fireplace performance keep the vent length and number of elbows to a minimum The air terminal must remain unobstructed at all times Examine the air terminal at least once a year to verify that it is unobstructed and undamaged Provide adequate ventilation and combustion air Provide adequate accessibility clearance for servicing and operating the fireplace Never obstruct the front opening of the fireplace W415 0619 B 03 03 08 6 VENT INSTALLATIONS For safe and proper operation of the fireplace follow the venting instruction exactly Deviation from the minimum
31. justed by loosening it s securing screws Figure 27 7 Once TORCH frame is perfectly square and the control door will close without rubbing against the sides of the TORCH frame tighten all screws 8 Open the control door 9 Insert the door stop chain into the receiving slot in the control door Figure 29 10 Insert the door stop chain into the receiving slot in the TORCH frame so that when fully open the control door has a clearance of 1 8 to the finished wall NOTE In most cases a count of 9 balls between receiving slots will give the desired clearance Figure 29 11 Close the control door The TORCH frame has been designed to accommodate finished material thicknesses of 500 750 If it is necessary to pull the TORCH frame out to the max 750 the magnetic catch will need to be adjusted Minor adjustment can be made by removing shims from behind the magnet Major adjustments can be made by moving the magnet to the outside of the panel Adjustment may be required to accommodate the door stop chain slack when the control door is closed The control door securing screws can be loosened to allow adjustment Before re tightening the screws ensure the control door is still recessed into the TORCH frame at a similar offset to the top trim piece FIGURE 29 eA TET AT RECEIVING SLOTS W415 0619 B 03 03 08 BRACKET FIGURE 28 FRAME BOTTOM
32. mediately call a qualified service technician to inspect the fireplace and replace any part of the control system and any gas control which has been under water slight odour for a few hours This is caused by dust particles in the heat exchanger burning off Open a window to sufficiently ventilate the room Purge all gas lines with the glass door of the fireplace open Assure that a continuous gas flow is at the burner before closing the door WHAT TO DO IF YOU SMELL GAS Turn off all gas to the fireplace Open windows Do not try to light any appliance Do not touch any electrical switch do not use any phone in your building Immediately call your gas supplier from a neighbor s phone Follow the gas supplier s instructions e If you cannot reach your gas supplier call the fire department LIGHTING INSTRUCTIONS 1 STOP Read the safety information located above 2 Turn off all electric power to the fireplace 3 This fireplace is equipped with an ignition device which automatically lights the burner Do not try to light by hand 4 Remove the glass door 5 Wait five 5 minutes to clear out any gas If you smell gas including near the floor STOP Follow B in the above safety information on this label If you don t smell gas go to the next step 6 Replace the glass door 7 Turn on all electric power to the fireplace 8 Turn the fireplace switch to the ON position 9 If fireplace will not operate follow
33. mponents used in the installation of the fireplace NAPOLEON warrants its stainless steel burners against defects in workmanship and material for life subject to the following conditions During the first 10 years N APOLEONSwill replace or repair the defective parts at our option free of charge From 10 years to life NAPOLEON will provide replacement burners at 50 of the current retail price In the first year only this warranty extends to the repair or replacement of warranted parts which are defective in material or workmanship provided that the product has been operated in accordance with the operation instructions and under normal conditions After the first year with respect to this President s Limited Lifetime Warranty NAPOLEON may at its discretion fully discharge all obligations with respect to this warranty by refunding to the original warranted purchaser the wholesale price of any warranted but defective part s After the first year NAPOLEON will not be responsible for installation labour or any other costs or expenses related to the reinstallation of a warranted part and such expenses are not covered by this warranty Notwithstanding any provisions contained in this President s Limited Lifetime Warranty NAPOLEON S responsibility under this warranty is defined as above and it shall not in any event extend to any incidental consequential or indirect damages This warranty defines the obligations and liability of NAPOLEON
34. nal 1 000ft This fireplace is approved for bathroom bedroom and bed sitting room installations and is suitable for mobile home installation The natural gas model can only be installed in a mobile home that is permanently positioned on its site and fueled with natural gas This fireplace may be installed in an aftermarket permanently located manufactured mobile home where not prohibited by local codes This fireplace is only for use with the type of gas indicated on the rating plate This fireplace is not convertible for use with other gases unless a certified kit is used Expansion contraction noises during heating up and cooling down cycles are normal and are to be expected Purge all gas lines with the glass door of the fireplace open Assure that a continuous gas flow is at the burner before closing the door Objects placed in front of the fireplace must be kept a minimum of 48 from the front face of the unit Use only Napoleon accessories designed for and listed with the model W415 0619 B 03 03 08 CARE OF GLASS AND PLATED PARTS The glass is 3 16 ceramic glass available from your H Napoleon Wolf Steel Ltd Do not substitute materials Use care when HOT GLASS WILL dealer Clean the glass after handling glass components do not stike CAUSE BURNS the first 10 hours of operation slam shut Do not operate with broken glass DO NOT TOUCH GLASS with a recommended gas UNTIL COOLED fireplace glass cle
35. nts check local codes Three feet above if within 10 feet horizontally A vent shall not terminate directly above a sidewalk or paved driveway that is located between two single family dwellings and serves both dwellings Permitted only if the veranda porch or deck is fully open on a minimum of two sides beneath the floor Recommenced to prevent recirculation of exhaust products For additional requirements check local codes W415 0619 B 03 03 08 INSTALLATION FRAMING WALL AND CEILING PROTECTION This application occurs when venting through an exterior FIGURE 5 wall Having determined the air terminal location cut and a frame a hole in an exterior wall with a minimum square opening of 8 wide x 8 high 1 Apply a bead of caulking all around and place the firestop spacer over the framework to restrict cold air from being drawn into the room or around the fireplace Ensure that the spacer maintains the required clearance to combustibles Secure the spacer in place using the 4 longer screws supplied Once the vent pipe is installed in its final position FIRESTOP apply high temperature sealant not supplied between the SPACER pipe and the firestop spacer r HIGH EMPERATURE A SEALANT OUTSIDE 7 VERTICAL INSTALLATION This application occurs when venting through a roof Installation kits for various roof pitches are available from your Napoleon dealer See Accessories to order the specific ki
36. o lighting the fireplace ensure that the logs are positioned correctly This appliance is certified to be installed in an aftermarket permanently located manufactured mobile home where not prohibited by local codes This fireplace is only for use with the type of gas indicated on the rating plate This fireplace is not convertible for use with other gases unless a certified kit is used Conversion Kits The mobile home appliance is field convertible between Natural Gas NG and Propane LP To convert from one gas to another consult your Napoleon dealer distributor W415 0619 B 03 03 08 13 GAS INSTALLATION Proceed once the vent installation is complete 77 00 FIGURE 16 Note All gas connections must be contained within the fireplace when zi xn complete We MD 1 The fireplace is designed to accept 1 2 gas supply line The fireplace is SHUT OFF VALVE FLEX CONNECTOR equipped with a 1 2 manual shut off valve 2 The access to the gas inlet is located on the bottom of the outer shell 3 The shut off must always be within the outer shell 4 When flexing any gas line support the gas valve so that the lines are not kinked 5 Check for gas leaks by brushing on a soap and water solution Do not use open flame FIGURE 17 LOCATION ELECTRICAL CONNECTION Do NOT use the fireplace if any part has been under wa
37. rom filling up the 1 air space around the pipe mg m COLLAR LA VENT PIPE PMELR SHIELD W415 0619 B 03 03 08 11 USING FLEXIBLE VENT COMPONENTS FIGURE 9 USE ONLY WOLF STEEL LTD 3 5 FLEXIBLE VENT COMPONENTS For safe and proper operation of the fireplace follow the venting instructions exactly SPACERS All 3 flexible vent pipe and 5 flexible vent pipe joints may be sealed using high temperature sealant W573 0002 not supplied or the high temperature sealant W573 0007 Mill Pac not supplied However the high temperature sealant W573 0007 Mill Pac not supplied must be used on the joint connecting the 3 flexible vent pipe and the exhaust Do not allow the 3 flexible vent pipe to bunch flue collar up on horizontal or vertical runs and elbows Use only approved flexible vent Pine kits marked Keep it pulled tight A 1 air gap between the 3 and 5 flexible vent pipes all around is required for safe operation spacer is required at the start middle and end of each K elbow to ensure this gap is maintained Spacers are attached to the 3 flexible vent pipe at predetermined intervals to maintain a 1 air gap to the 5 flexible vent pipe These Wolf Steel Approved Venting as identified by the stamp only on the 5 flexible vent pipe spacers must not be removed Four inches 4 is the minimum bend radius allowed for the
38. rt 3280 in the United States or in the Mobile Home Standard CAN CSA Z240 MH Series in Canada This appliance is only for use with the type of gas indicated on the rating plate This appliance is not convertible for use with other gases unless a certified kit is used This appliance may be installed in an aftermarket permanently located manufactured home USA only or mobile home where not prohibited by local codes This appliance is only for use with the type of gas indicated on the rating plate This appliance is not convertible for use with other gases unless a certified kit is used Do not burn wood or other materials in this fireplace Adults and especially children should be alerted to the hazards of high surface temperatures and should stay away to avoid burns or clothing ignition Supervise young children when they are in the same room as the fireplace Clothing or other flammable material should not be placed on or near the fireplace Due to high temperatures the fireplace should be located out of traffic and away from furniture and draperies Ensure you have incorporated adequate safety measure to protect infants toddlers from touching hot surfaces Even after the fireplace is out the glass and or screen will remain hot for an extended period of time Check with your local hearth specialty dealer for safety screens and hearth guards to protect children from hot surfaces These screens and guards must be fastened to the floor An
39. t required FIGURE 6 1 Determine the air terminal location cut and frame a 8 square opening in the ceiling and the roof to provide the minimum clearance between the vent pipe and any combustible material Try to center the vent pipe location midway between two joists to prevent having to cut them Use a plumb bob to line up the center of the openings Do not fill this space with any type of material A vent pipe shield will prevent any materials such as insulation from filling up the 1 air space around the pipe Nail headers between the joist for extra support 2 Apply a bead of caulking not supplied to the framework or to the Wolf Steel vent pipe shield plate or FIRESTOP equivalent in the case of a finished ceiling and secure UNDERSIDE OF JOIST over the opening in the ceiling A firestop must be placed on the bottom of each framed opening in a roof or ceiling that the venting system passes through Apply a bead of caulking all around and place a firestop spacer over the vent shield to restrict cold air from being drawn into the room or around the fireplace Ensure that both spacer and shield maintain the required clearance to combustibles Once the vent pipe is installed in its final position apply sealant between the pipe and the firestop assembly 3 In the attic slide the vent pipe collar down to cover up the open end of the shield and tighten This will prevent any materials such as insulation f
40. ter Call a qualified service technician IMMEDIATELY to have the fireplace inspected for damage to the electrical circuit HARD WIRING CONNECTION IT IS NECESSARY TO HARD WIRE THIS FIREPLACE Permanently framing the fireplace with an enclosure requires the fireplace junction box to be hard wired This fireplace must be electrically connected and grounded in accordance with local codes In the absence of local codes use the current CSA C22 1 CANADIAN ELECTRICAL CODE in Canada or the ANSI NFPA 70 1996 NATIONAL ELECTRICAL CODE in the United States FIGURE 18 SWITCH JUNCTION BOX c w 2 receptacles W415 0619 B 03 03 08 14 NAILING TAB INSTALLATION Attach the 4 nailing tabs supplied to the sides of the outer shell as illustrated using the 8 self tapping screws included in the manual baggie FIGURE 20 The TORCH has been designed to be installed mid way up a wall When installing this unit close to the finished floor the unit must be raised a minimum of 2 unobstructed to allow for full rotation of the control door It is not necessary to install a hearth extension Although the unit fits between studs most jurisdictions will not allow a hole in the warm air envelope of a residential structure It is recommended to build either an interior or exterior chase with a minimum depth of 7 It is best to frame your fireplace after it is positioned and the vent system is install
41. y safety screen or guard removed for servicing must be replaced prior to operating the fireplace It is imperative that the control compartment and burner in the fireplace and venting system are kept clean The fireplace and its venting system should be inspected before use and at least annually by a qualified service person More frequent cleaning may be required due to excessive lint from carpeting bedding material etc The fireplace area must be kept clear and free from combustible materials gasoline and other flammable vapours and liquids Under no circumstances should this fireplace be modified This fireplace must not be connected to a chimney flue pipe serving a separate solid fuel burning appliance Do not use this fireplace if any part has been under water Immediately call a qualified service technician to inspect the fireplace and to replace any part of the control system and any gas control which has been under water Do not operate the fireplace with the glass door removed cracked or broken Replacement of the glass should be done by a licensed or qualified service person Do not strike or slam shut the fireplace glass door The glass door must be kept closed while the fireplace is operating to prevent exhaust fumes containing carbon monoxide from entering into the home Temperatures of the exhaust escaping through this opening can also cause the surrounding combustible materials to overheat and catch fire Only doors optional fronts c