Home
N-Tron 105FX-POE User's Manual
Contents
1. NT This product complies with Part 15 of the FCC A Rules Operation is subject to the following conditions 1 This device may not cause harmful interference 2 This device must accept any interference received including interference that may cause undesired operation NOTE This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications Operation of this device in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense INDUSTRY CANADA This Class A digital apparatus meets all requirements of the Canadian Interference Causing Equipment Regulations Operation is subject to the following two conditions 1 this device digital apparatus meets all requirements of the Canadian Interference Causing Equipment Regulations Operation is subject to the following two conditions 1 this device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation Cet appareillage num rique de la cl
2. 40 C to 85 C 40 C to 85 C 10 to 90 Non Condensing 0 to 10 000 ft gt Cat 3 Cable gt Cat 5 Cable Multimode 50 62 5 125u m Fiber Singlemode 7 10 125um Fiber Fiber Length 2km 15km 40km S0km TX Power Min Max 9dBm 14dBm 15dBm 7dBm 5dBn 0dBm 5dBn 0dBm RX Sensitivity Max 32dBm 34dBm 34dBm 34dBm Wavelength 1310 1310 1310 1550 Multimode Singlemode Connectors 10 100BaseTX RJ45 UTP Port 100BaseFX SC or ST Duplex Port Recommended Minimum Wiring Clearance Front 2 5 08 cm Top 1 2 54 Rev 041008 N TRON Limited Warranty N TRON Corp warrants to the end user that this hardware product will be free from defects in workmanship and materials under normal use and service for the applicable warranty period from the date of purchase from N TRON or its authorized reseller If a product does not operate as warranted during the applicable warranty period N TRON shall at its option and expense repair the defective product or part deliver to customer an equivalent product or part to replace the defective item or refund to customer the purchase price paid for the defective product products that are replaced will become the property of N TRON Replacement products may be new or reconditioned Any replaced or repaired product or part has a ninety 90 day warranty or the remainder of the initial warranty period whicheve
3. 041008 8 FRONT PANEL From Top to Bottom Power LED POE POE Status LED SPD Speed LED 105TX POE only LNK ACT Link Activity LED RJ45 Ports Auto sensing 10 100BaseT Connection LED MODE OF OPERATION LED Color Description 4 Green Valid Power 46 54 VDC is applied Red Invalid Power lt 46 VDC is applied or Power Bus Fault detected OFF No Power is applied to the device Dua Green Valid Power 46 54 VDC is applied Red Invalid Power lt 46 VDC is applied or Power Bus Fault detected OFF No Power is applied to the device POE Green POE is being applied on the respective port Blinking POE PD detected with improper power classification OFF No POE PD detected on the port LNK Green Link with no or little activity ACT Blinking Link with activity OFF No link established SPD Green 100 Base 100 OFF 10 Base LNK Green Link established on the fiber uplink port 105FX POE OFF No link established on fiber uplink port 105FX POE ACT Blinking Activity present OFF No activity Note Redundant power inputs will not balance the power load Only load from one power supply is used at a time Rev 041008 APPLYING POWER Top View CHASSIS GROUND V Negative GND Return V Positive 46 54VDC Negative GND Return V Positive 46 54VDC DETAIL Unscrew amp Remove the DC Voltage Inp
4. 3 Website www n tron com Email N TRON_Support n tron com Rev 041008 GENERAL SAFETY WARNINGS WARNING Do not operate the equipment in the presence of flammable gasses or fumes Operating electrical equipment in such an environment constitutes a definite safety hazard WARNING If the equipment is used in the manner not specified by N TRON Corp the protection provided by the equipment may be impaired WARNING Do not perform any services on the unit unless qualified to do so Do not substitute unauthorized parts or make unauthorized modifications to the unit WARNING Do not operate the unit with the end plates removed as this could create a shock or fire hazard WARNING Do not operate the equipment in a manner not specified by this manual ENVIRONMENTAL SAFETY WARNINGS WARNING Disconnect the power and allow to cool 5 minutes before touching ELECTRICAL SAFETY WARNINGS WARNING Disconnect the power cable before removing the end plates WARNING Do not operate the unit with the end plates removed WARNING Do not work on equipment or cables during periods of lightning activity WARNING Do not perform any services on the unit unless qualified to do so WARNING Observe proper DC Voltage polarity when installing power input cables Reversing voltage polarity can cause permanent damage to the unit and void the warranty Rev 041008 HAZARDOUS LOCATIO STALLATION REQUIRE 1 This equipment is suitable
5. ENT FIRE LIGHTNING POWER CUTS OR OUTAGES OTHER HAZARDS OR ACTS OF GOD LIMITATION OF LIABILITY TO THE FULL EXTENT ALLOWED BY LAW N TRON ALSO EXCLUDES FOR ITSELF AND ITS SUPPLIERS ANY LIABILITY WHETHER BASED IN CONTRACT OR TORT INCLUDING NEGLIGENCE FOR INCIDENTAL CONSEQUENTIAL INDIRECT SPECIAL OR PUNITIVE DAMAGES OF ANY KIND OR FOR LOSS OF REVENUE OR PROFITS LOSS OF BUSINESS LOSS OF INFORMATION OR DATA OR OTHER FINANCIAL LOSS ARISING OUT OF OR IN CONNECTION WITH THE SALE INSTALLATION MAINTENANCE USE PERFORMANCE FAILURE OR INTERRUPTION OF ITS PRODUCTS EVEN IF N TRON OR ITS AUTHORIZED RESELLER HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES AND LIMITS ITS LIABILITY TO REPAIR REPLACEMENT OR REFUND OF THE PURCHASE PRICE PAID AT N TRON S OPTION THIS DISCLAIMER OF LIABILITY FOR DAMAGES WILL NOT BE AFFECTED IF ANY REMEDY PROVIDED HEREIN SHALL FAIL OF ITS ESSENTIAL PURPOSE DISCLAIMER Some countries states or provinces do not allow the exclusion or limitation of implied warranties or the limitation of incidental or consequential damages for certain products supplied to consumers or the limitation of liability for personal injury so the above limitations and exclusions may be limited in their application to you When the implied warranties are not allowed to be excluded in their entirety they will be limited to the duration of the applicable written warranty This warranty gives you specific legal rights which may vary dependi
6. THE INDUSTRIAL NETWORK COMPANY 105TX POE amp 105FX POE Unmanaged Industrial Ethernet POE Switches User Manual amp Installation Guide Rev 041008 THE INDUSTRIAL NETWORK COMPANY Industrial Power over Ethernet Installation Guide 105TX POE 105FX XX POE 105 Where ST or SC and YY 15 40 80 Rev 041008 Copyright N TRON Corp 2008 820 S University Blvd Suite 4E Mobile AL USA 36609 All rights reserved Reproduction adaptation or translation without prior written permission from N TRON Corp is prohibited except as allowed under copyright laws Ethernet is a registered trademark of Xerox Corporation All other product names company names logos or other designations mentioned herein are trademarks of their respective owners The information contained in this document is subject to change without notice N TRON Corp makes no warranty of any kind with regard to this material including but not limited to the implied warranties of merchantability or fitness for a particular purpose In no event shall N TRON Corp be liable for any incidental special indirect or consequential damages whatsoever included but not limited to lost profits arising out of errors or omissions in this manual or the information contained herein Contact Information N TRON Corp 820 South University Blvd Suite 4E Mobile AL 36609 TEL 251 342 2164 FAX 251 342 635
7. ackup for all these devices The 105FX POE utilizes the IEEE compliant SC or ST duplex connectors for fiber optic communication All 10 100Base TX ports utilize the RJ45 shielded connectors Key Features Compact space saving package Full IEEE 802 3 amp 100Base FX Compliance IEEE 802 3af Compliant 105TX POE Five 10 100Base TX RJ 45 ports 4 PSE ports and 1 uplink port 105FX POE Four 10 100Base TX RJ 45 ports 4 PSE ports and 1 100BaseFX fiber uplink port Unmanaged operation Extended Environmental Specifications 40 C to 85 C Operating Temperature 40 C to 85 C Storage Temperature Operating Humidity 10 to 90 Non Condensing Support for Full Half Duplex Operation LED Link Activity Status Indication LED POE Status Indication Power Fault Status LEDs Auto negotiation Auto sensing Speed Duplex and Flow Control Up to 1 0 Gb s Maximum Throughput Industry Standard 35mm DIN Rail Mounted Enclosure Redundant power inputs 46 49 VDC Supports up to 15 4Watts per channel 13 Watts at the Powered Device PD Full wire speed communications Hardened metal DIN Rail Enclosure FECES Rev 041008 PACKAGE CONTENTS Please make sure the switch package contains the following items 1 105TX POE or 105FX E POE 2 Instruction Sheet Contact your carrier if any items are damaged UNPACKING Remove all the equipment from the packaging and store the packaging in a safe place File any damage claims with the carrier CLEANING C
8. an be supplied with optional plastic brackets if isolation is required Users may run a drain wire amp lug from the screw provided on the back face of the enclosure In the event the provided grounding screw has been lost care should be taken to limit the penetration of the outer skin by less than 1 4 Failure to do so may cause irreversible damage to the internal components of the switch Note Ensure the power supply is grounded properly before applying power to the grounded switch This may be verified by using a voltmeter to determine that DRAIN WIRE WITH LUGS there is no voltage difference between the power supply s negative output terminal SO KNOWN GROUNDING POINT and the chassis grounding point of the switch NONMETALLIC DIN RAIL MOUNT As an alternative grounding method both V legs of the power input connector are connected to chassis internally on the PCB Connecting a drain wire to earth ground from one of the V terminal plugs as A be DRAIN WIRE WITH LUG shown here will ground the switch and the chassis The power leads CONNECTING SWITCH CHASSIS ae f TO KNOWN GROUNDING POINT from the power source should be limited to 3 meters or less in length If the use of shielded cables is required it is generally recommended to only connect the shield at one end to prevent ground loops and interfere with low level signals i e thermocouples RTD etc CatSe cables manufactured to EIA 568A or 568B specifications are requir
9. asse A r pond toutes les exigences de l interf rence canadienne causant des r glements d quipement L op ration est sujette aux deux conditions suivantes 1 ce dispositif peut ne pas causer l interf rence nocive et 2 ce dispositif doit accepter n importe quelle interf rence regue y compris l interf rence qui peut causer l op ration peu d sir e Rev 041008 16 Regulatory Approvals Safety UL Listed per ANSI ISA 12 12 01 2000 US and Canada This apparatus is suitable for use in Class I Div 2 Groups B C D T4 EMI EN 61000 6 4 EN 55011 Class A FCC Title 47 Part 15 Subpart B Class A ICES 003 Class A EMS EN6 1000 6 2 IEC 61000 4 2 ESD IEC 1000 4 3 RS IEC 61000 4 4 EFT IEC 61000 4 5 Surge IEC 61000 4 6 Conducted Disturbances Warranty 3 years from the date of purchase Rev 041008 KEY SPECIFICATIONS Physical Height Width Depth Including Din Rail Clip Weight Electrical Input Voltage Input Current Inrush Current Input Ripple Input Wire Size Environmental Operating Temperature Storage Temperature Operating Humidity Operating Altitude Network Media 10 100BaseT 100BaseFX Fiber Transceiver Characteristics 3 50 8 89 cm 1 50 3 81 cm 4 22 10 72 cm 0 70 Ibs 0 32 kg 46 49 VDC 1 6 A 48 VDC under full load 65 mA 48 VDC no POE in use switch in full use 26 Amp 1 3 ms 48VDC Less than 100 mV 10 20 AWG
10. ed for use with N Tron Switches METALLIC NONMETALLIC SHIELDED PATCH CABLE Note Strain relief boots not shown for clarity purposes In the event all Cat5e patch cable distances are small i e All Ethernet devices are located the same local cabinet and or referenced to the same earth ground it is permissible to use fully shielded cables terminated to chassis ground at both ends in systems void of low level analog signals Rev 041008 RJ45 CONNECTOR CRIMP SPECIFICATIONS Please reference the illustration below for your Cat5 cable specifications 0 232 30 005 15 89 0 127 5 CABLE 0 237 40 005 6 0220 13 5 CABLE Rev 041008 TYPICAL APPLICATIONS Rev 041008 STAR TOPOLOGY e LAN Devices POE AP Ch X M CAT5e Cable e canne Cable with POE Fiber Optic Cable 405FX ST POE RING TOPOLOGY N TRON 7014 2 ERRER 3 Building A N Ring Manager Building B N Ring AutoMember Building C N Ring AutoMember Rev 041008 Fibor Optic Cable TL CAT5e Cable with POE tosTk PoE porem Seip nae POE weamera POE iP Phone CONNECTING THE UNIT For the 100BaseFX Fiber Optic p
11. for use in Class I Div 2 Groups A B C and D or unclassified or non hazardous locations only 2 WARNING Explosion Hazard Substitution of components may impair suitability for Class I Division 2 3 WARNING Explosion hazard do not disconnect while the circuit is live or unless the area is known to be non hazardous 4 WARNING Explosion Hazard Do not remove or replace the device unless power has been switched off or the area is known to be non hazardous 5 Use 60 75 rated Copper wire 0 22Nm 2 inch Ibs Tightening torque for field installed connectors 6 WARNING Install only in accordance with Local amp National Codes of Authorities Having Jurisdiction 7 Class 1 Div 2 installations require that all devices connected to this product must be UL listed for the area in which it is installed 8 WARNING Damage may occur to the RJ 45 port of the powered device PD if the switch is not powered down before disconnecting the Cat5 cable Rev 041008 5 Functional Overview The 105 and 105FX POE Power over Ethernet Unmanaged Industrial Ethernet Switches are designed to provide power over Ethernet for POE capable devices where running a power line is either not possible or not cost effective This feature allows an end user to power a POE camera wireless access point or any other POE capable device without the need for running separate wires for power This also allows the ability for a centralized battery b
12. le in all locations When an advance replacement is provided and customer fails to return the original product to N TRON within fifteen 15 days after shipment of the replacement N TRON will charge customer for the replacement product at list price WARRANTIES EXCLUSIVE IF AN N TRON PRODUCT DOES NOT OPERATE AS WARRANTED ABOVE CUSTOMER S SOLE REMEDY FOR BREACH OF THAT WARRANTY SHALL BE REPAIR REPLACEMENT OR REFUND OF THE PURCHASE PRICE PAID AT N TRON S OPTION TO THE FULL EXTENT ALLOWED BY LAW THE FOREGOING WARRANTIES AND REMEDIES ARE EXCLUSIVE AND ARE IN LIEU OF ALL OTHER WARRANTIES TERMS OR CONDITIONS EXPRESS OR IMPLIED EITHER IN FACT OR BY OPERATION OF LAW STATUTORY OR OTHERWISE INCLUDING WARRANTIES TERMS OR CONDITIONS OF MERCHANTABILITY FITNESS FOR A PARTICULAR PURPOSE SATISFACTORY QUALITY CORRESPONDENCE WITH DESCRIPTION AND NON INFRINGEMENT ALL OF WHICH ARE EXPRESSLY DISCLAIMED N TRON NEITHER ASSUMES NOR AUTHORIZES ANY OTHER PERSON TO ASSUME FOR IT ANY OTHER LIABILITY IN CONNECTION WITH THE SALE INSTALLATION MAINTENANCE OR USE OF ITS PRODUCTS N TRON SHALL NOT BE LIABLE UNDER THIS WARRANTY IF ITS TESTING AND EXAMINATION DISCLOSE THAT THE ALLEGED DEFECT OR MALFUNCTION IN THE PRODUCT DOES NOT EXIST OR WAS CAUSED BY CUSTOMER S OR ANY THIRD PERSON S MISUSE NEGLECT IMPROPER INSTALLATION OR TESTING UNAUTHORIZED ATTEMPTS TO OPEN REPAIR OR MODIFY THE PRODUCT OR ANY OTHER CAUSE BEYOND THE RANGE OF THE INTENDED USE OR BY ACCID
13. lean only with a damp cloth INSTALLATION Read the following warnings before beginning the installation WARNING Never install or work on electrical equipment or cabling during periods of lightning activity Never connect or disconnect power when hazardous gasses are present LASER SAFETY 105FXE 40 and 80 Only WARNING CLASS 1 LASER PRODUCT Do not stare into the laser Rev 041008 DIN Rail Mounting Install the unit in a standard DIN rail Recess the unit to allow at least 2 of horizontal clearance for CATSe cable bend radius To install the unit to 35mm industrial DIN rail To remove the unit from the 35mm industrial place the top edge of the included mounting DIN rail place a flat head screwdriver into the bracket on the back of the unit against the DIN release clip found at the bottom of the unit and rail at a 15 angle as shown Rotate the bottom of apply downward force on the clip until it the unit to the back away from you until it disengages from the bottom of the unit from the snaps into place DIN rail Rotate the bottom of the unit towards you and up at an approximate 15 upward angle to completely remove the unit Most N Tron products designed to be mounted on industry standard 35mm DIN rail However DIN rail mounting may not be suitable for all applications Our Rack Mount Assembly P N 900 RM may be used to mount the 10STX FX POE enclosures to standard 19 racks as an option Rev
14. ng on local law GOVERNING LAW This Limited Warranty shall be governed by the laws of the State of Alabama U S A Rev 041008
15. ort 105FX POE remove the dust cap s from the fiber optic connector and connect the fiber optic cables The TX port on the local unit should be connected to the RX port of the far end device and the RX port should be connected to the TX port of the far end device For 10Base T ports plug a Category 3 or greater twisted pair cable into the RJ45 connector For 100Base T ports plug a Category 5 or greater twisted pair cable into the RJ45 connector Connect the other end to the far end station Verify that the LNK LED s are ON once the connection has been completed To connect any other port to another Switch or Repeater use a standard Cat5 straight through or crossover cable Warning Creating a port to port connection on the same switch i e loop is an illegal operation and will create a broadcast storm which will crash the network TROUBLESHOOTING 1 Make sure the Power LED is ON 2 Make sure you are supplying sufficient current for the 105 or 105 and all powered devices plugged into it Note The inrush current and steady state current is dependent on the power requirements of the powered devices plugged into the POE switch 3 Verify that the POE light is on solid if a valid POE PD is connected to the port 4 Verify that Link LED s are ON for both ports 5 Verify cabling used between stations 6 Verify that cabling is Category 3 or greater for 10 Operation Rev 041008 15 FCC STATE
16. r is longer N TRON shall not be responsible for any custom software or firmware configuration information or memory data of customer contained in stored on or integrated with any products returned to N TRON pursuant to any warranty OBTAINING WARRANTY SERVICE Customer must contact N TRON within the applicable warranty period to obtain warranty service authorization Dated proof of purchase from N TRON or its authorized reseller may be required Products returned to N TRON must be pre authorized by N TRON with a Return Material Authorization RMA number marked on the outside of the package and sent prepaid and packaged appropriately for safe shipment Responsibility for loss or damage does not transfer to N TRON until the returned item is received by N TRON The repaired or replaced item will be shipped to the customer at N TRON s expense not later than thirty 30 days after N TRON receives the product N TRON shall not be responsible for any software firmware information or memory date of customer contained in stored on or integrated with any products returned to N TRON for repair whether under warranty or not ADVANCE REPLACEMENT OPTION Upon registration this product qualifies for advance replacement A replacement product will be shipped within three 3 days after verification by N TRON that the product is considered defective The shipment of advance replacement products is subject to local legal requirements and may not be availab
17. ut Plug from the top header Install the DC Power Cables into the Plug observing polarity on unit Plug the Voltage Input Plug back into the top header Tightening torque for the terminal block power plug is 0 22 Nm 0 162 Pound Foot Turn the power on the wire Note It is only safe to turn the power on the wires after the wires have been secured to the switch WARNING Inserting the input plug while the 48VDC is applied may cause arcing and damage the input connector permanently Note Either V or V2 can be connected to power for minimal operation For redundant power operation V and V5 plugs must be connected to separate DC Voltage sources Use wire sizes of 10 20 gauge The power cord should be limited to less than 10 meters in order to ensure optimum performance Recommended 48V DC Power Supplies similar to 100 240VAC N Tron NTPS 48 5 DC 48V 5A Rev 041008 10 N TRON GROUNDING TECHNIQUES FOR 105 AND 105 The grounding philosophy of any control system is an integral part of the design N Tron switches are designed to be grounded but the user has been given the flexibility to float the switch when required The best noise immunity and emissions i e CE are obtained when the N Tron switch chassis is connected to earth ground via a drain wire Some N Tron switches have metal din rail brackets that can ground the switch if the din rail is grounded In some cases N Tron switches with metal brackets c
Download Pdf Manuals
Related Search
Related Contents
EN - User`s manual () TÉLÉVISION & cINÉma MH 3 Beam Bedienungsanleitung Copyright © All rights reserved.
Failed to retrieve file