Home

Multiquip GB12BS User's Manual

image

Contents

1. 21 23 Setup GB12BS 24 25 Operation GB12BS 26 Maintenance 27 31 Wiring Diagram 32 Troubleshooting 33 Explanation Of Code In Remarks Column 34 Suggested Spare Parts 35 Component Drawings Nameplate And Decals GB12BW 36 37 Nameplate And Decals GB12BS 38 39 Nameplate And Decals GB12BP 40 41 Mast Tripod Assy 42 43 Fan Blower Lamp Assy 44 45 Balloon Lamp Guard Assy 46 47 Offset Pole Assy GB12BS 48 49 Terms And Conditions Of Sale Parts 50 NOTICE Specifications and part numbers are subject to change without notice gb12bw bs bp LIgHTINg sYsTeM operaTIoN aNd parTs MaNuaL rev 0 06 24 13 page 5 Parts orDerinG ProCeDures www multiquip com ordering parts has never been easier Choose from three easy options we aCCepT aLL MaJor CredIT Cards When ordering parts please supply dealer account Number dealer Name and address shipping address if different t
2. Lighting system is equipped with a ground pin on the power plug For your protection ALWAYS complete the grounding path Never insert the AC power plug into a 2 prong receptacle to operate lighting system When applying power to the lighting system ALWAYS connect the AC power plug to a 3 prong receptacle that is grounded The possibility exists of electrical shock electrocution and even death if the lighting system is not grounded Never operate lighting system or handle any electrical equipment while standing in water while barefoot while hands are wet or in the rain A dangerous electrical shock could occur causing severe bodily harm or even death ALWAYS make sure the area above the lighting system is open and clear of overhead power lines and other obstructions Contact with overhead power lines or other obstructions could result in equipment damage electrical shock electrocution and even death power Cord Cable safety daNger Never let power cords or cables lay in water Never use damaged or worn cables or cords Inspect for cuts in the insulation Never grab or touch a live power cord or cable with wet hands The possibility exists of electrical shock electrocution or death Make sure power cables are securely connected Incorrect connections may cause electrical shock and damage to the lighting system NOTICE ALWAYS make certain that proper power or extension cord
3. 10 1 7 3 COVER CARRYING CASE 9 GB12BS GB12BW GB12BP 12 13 15 16 1 14 gb12bw bs bp LIgHTINg sYsTeM operaTIoN aNd parTs MaNuaL rev 0 06 24 13 page 17 ComPonents Figure 7 shows the location of the components for the GloBug lighting system The function of each component is described below 1 aC power Cable Connect this cable to a 120 VAC 60 Hz power source 2 balloon This balloon is made of heat resistant polyester with a diameter of 33 inches 850 mm 3 balloon Cover Carrying Case When zipped this protective cover acts like a carrying case The complete lamp assembly is enclosed within the cover carrying case Allow a sufficient amount of time for the lamp to cool down before covering balloon The possibility exists of the balloon getting burned 4 Mast Two stage air assist mast Maximum mast height is 10 ft 3 meters without optional extension pole With optional extension pole height increases to 13 ft 4 meters When raising the mast always be on the lookout for overhead obstructions 5 T Handle bolt Lock Always tighten this lock to hold the lamp balloon securely in place before raising mast 6 Tripod release Latch Use this latch to deploy and lock tripod legs For ease of use the latch mechanism is attached to a velcro strap 7 Tripod Unbuckle velcro strap securing tripod legs 3 push down on any tripod leg until all tr
4. 8 6 19 23 24 25 17 7 1 10 2 10 3 7 6 4 5 8 9 gb12bw bs bp LIgHTINg sYsTeM operaTIoN aNd parTs MaNuaL rev 0 06 24 13 page 47 No parT No parT NaMe QTY reMarKs 1 E000125500 LAMP MP400 1 2 E000038200 RUBBER 1 3 A300273200 SOCKET ASSY 1 4 0023304015 SCREW AND WASHER M4x15 2 5 A300160602 PLATE LAMP 1 6 A400195200 STOPPER 4 7 0024304004 SCREW M4x4 8 8 0023405012 SCREW M5x12 4 9 A300174000 LAMP HOLDER 1 10 A300171902 MAIN POLE 4 12 2214500230 SEAL FLAT 1 13 A300160301 SHEET TOP 1 14 A100048003 BALLOON COVER 1 15 0014710025 BUTTON SCREW M10x25 4 16 A300162400 SEAL PACKING 1 17 A300165100 PLATE TOP 2 19 0023304012 SCREW AND WASHER M4x12 4 23 A400199500 PACKING LAMP 4 24 0043104000 WASHER M4 4 25 0033104000 NUT M4 4 36 A100015901 BALLOON CLOTH 1 39 0043210000 SPRING WASHER M10 8 41 0043110000 WASHER M10 4 42 A100061300 LAMP GUARD 1 46 A300067700 BLANK MESSAGE STRIP 1 balloon lamP GuarD assy page 48 gb12bw bs bp LIgHTINg sYsTeM operaTIoN aNd parTs MaNuaL rev 0 06 24 13 offset Pole assy Gb12bs 2 6 5 4 3 1 7 gb12bw bs bp LIgHTINg sYsTeM operaTIoN aNd parTs MaNuaL rev 0 06 24 13 page 49 No parT No parT NaMe QTY reMarKs 1 A200056702 OFFSET POLE 1 2 A300166600 POLE 1 3 E000077100 KNOB 1 4 E000093401 CLAMP 2
5. assembly Kit All items on the parts list with the same unique symbol will be included when this item is purchased Indicated by INCLUDES ITEMS W unique symbol Serial Number Break Used to list an effective serial number range where a particular part is used Indicated by S N XXXXX AND BELOW S N XXXX AND ABOVE S N XXXX TO S N XXX Specific model Number Use Indicates that the part is used only with the specific model number or model number variant listed It can also be used to show a part is NOT used on a specific model or model number variant Indicated by XXXXX ONLY NOT USED ON XXXX make Obtain locally Indicates that the part can be purchased at any hardware shop or made out of available items Examples include battery cables shims and certain washers and nuts Not Sold Separately Indicates that an item cannot be purchased as a separate item and is either part of an assembly kit that can be purchased or is not available for sale through Multiquip gb12bw bs bp LIgHTINg sYsTeM operaTIoN aNd parTs MaNuaL rev 0 06 24 13 page 35 suGGesteD sPare Parts gLobug LIgHTINg sYsTeM 1 To 3 uNITs Qty p N description 2 E000125500 LAMP 2 A300275800 ELE BALLAST ASSY 2 A100015901 BALLOON CLOTH page 36 gb12bw bs bp LIgHTINg sYsTeM operaTIoN aNd parTs MaNuaL rev 0 06 24
6. know the phone numbers of the nearest ambulance doctor and fi re department This information will be invaluable in the case of an emergency page 8 gb12bw bs bp LIgHTINg sYsTeM operaTIoN aNd parTs MaNuaL rev 0 06 24 13 safety information LIgHTINg sYsTeM saFeTY warNINg Never disconnect any emergency or safety devices These devices are intended for operator safety Disconnection of these devices can cause severe injury bodily harm or even death Disconnection of any of these devices will void all warranties CauTIoN Never attempt service on a running machine NOTICE To prevent the lighting system from overturning Never use in winds that exceed 22 mph 10 m s The lighting system should only be used in temperatures between 23 to 104 F 5 to 40 C Failure to comply with these operating parameters could cause the lamp to malfunction and shorten the ballast life ALWAYS keep the lighting system in proper running condition Fix damage to lighting system and replace any broken parts immediately ALWAYS store equipment properly when it is not being used Equipment should be stored in a clean dry location out of the reach of children and unauthorized personnel LaMp saFeTY warNINg Never attempt to replace lamp with the power on Always unplug the power cord from the generator or power source when changing the lamp ALWAYS allow a suffi cient amount of
7. n s e o d p m a L d etc e n n o c sid g ulp sI yltc e rro c ni g ulP ffo d e h cti w s re w o p p m al sI h cti w s n o n ru T e s o ol p m al sI te k c o s otni yle ru c e s p m al w e rc S e s o ol ro d etc e n n o c sid rotc e n n o c re w o p sI rotc e n n o c d etc e n n o c sid tc e n n o C re hto s e c n ailp p a cirtc ele re hto y n a e r A re w o p otni d e g g ulp re w ot th gil n a ht e cru o s s e c n ailp p a re hto lla g ulp n U elbita p m o c ni p m alfo le d o m sI p m al Q M e niu n e g e s U nia g a th gil ot h g u o n e lo o c to n p m al sI d e riu q e r si s etu ni m 0 3 ot 0 2 fo la vretnI nia g a p m al n o g nin rut e rofe b n w o d lo o c ot p m alrof tia W a rof sth gil yln o p m a L e m it tro h s n a ht e ro m h gih o ot e ruta re p m et tn eib m a sI C 0 4 F 4 0 1 re p o rp si e re ht e re h w p m al e v o M n oitalitn e v to n s e o d n o olla B etalfni ylre p o rp g nikro w to n re w olb roto m n af sI re w olb roto m n af ria p e r ro k c e h C e vitc efe d e p ole v n
8. 0 06 24 13 page 9 safety information baLLooN saFeTY warNINg To prevent serious burns Never touch or unzip the balloon envelope when the lamp is on CauTIoN ALWAYS keep the balloon away from sharp objects and excessive amounts of heat NOTICE To prevent balloon deformation Never use lighting system in strong winds do NoT place the balloon inside its protective cover until the lamp has had a suffi cient amount of time to cool down This will prevent the balloon s nylon cover from being burned touching the lamp surface ALWAYS place the balloon inside its protective cover after each use This will prolong the life of the balloon material keeping it protected from harsh environmental elements Replace balloon immediately if damaged A damaged balloon will not infl ate properly and may become more damaged by touching the hot lamp surface do NoT use excessive force when zipping and unzipping the balloon Be gentle with the zipper mechanism If the zipper is broken the balloon will become unusable MasT saFeTY CauTIoN When raising or lowering the mast keep hands and fi ngers clear of the various mast sections this will prevent hands and fi ngers from getting pinched Never attach anything to the mast ALWAYS lower the mast when not in use or if high winds or electrical storms are expected in the area PINCH POINT MAST eLeCTrICaL saFeTY daNger
9. 13 namePlate anD DeCals Gb12bW 1 15 2 3 14 5 4 12 10 7 8 6 9 11 16 MODEL SERIAL NO 13 gb12bw bs bp LIgHTINg sYsTeM operaTIoN aNd parTs MaNuaL rev 0 06 24 13 page 37 namePlate anD DeCals Gb12bW No parT No parT NaMe QTY reMarKs 1 A400324800 DECAL GLOBUG INFORMATION ELECTRIC SHOCK 1 2 A400166701 DECAL LATCH RIGHT 1 3 A400324100 DECAL LATCH LEFT 1 4 A400194100 DECAL DANGER WORKSTAND DEPLOYMENT ENGLISH 1 5 A400324300 DECAL DANGER WORKSTAND DEPLOYMENT FRENCH 1 6 A400326300 DECAL CAUTION LAMP TYPE 1 7 A400290900 DECAL CAUTION LAMP INFORMATION ENGLISH 1 8 A400324200 DECAL CAUTION LAMP INFORMATION FRENCH 1 9 A400084300 DECAL GROUND 2 10 A400323900 DECAL LIGHT CONTROL SWITCH 1 11 A400325000 DECAL CAUTION AC ONLY 1 12 A400325100 DECAL ELECTRIC SHOCK HIGH VOLTAGE BURN HAZ 1 13 A400206000 DECAL DIMMER SWITCH 1 14 A400193300 DECAL GLOBUG LIGHTING SYSTEM 1 15 A400290801 DECAL GB12BW 003 1 16 NAMEPLATE 1 CONTACT MQ PARTS page 38 gb12bw bs bp LIgHTINg sYsTeM operaTIoN aNd parTs MaNuaL rev 0 06 24 13 namePlate anD DeCals Gb12bs 2 1 2A back of item 2 10 7 11 4 5 3 6 9 8 MODEL SERIAL NO gb12bw bs bp LIgHTINg sYsTeM operaTIoN aNd parTs MaNuaL rev 0
10. 20 minutes to cool before changing Figure 35 Hot Lamp Surface 2 If lamp assembly is attached to mast loosen upper T handle bolt lock that secures the lamp to the mast and remove 3 Unzip the zipper at the bottom of the balloon do NoT use excessive force when unzipping the balloon 4 Place lamp balloon assembly on a suitable work bench that is free of dirt and sharp objects that could damage the balloon 5 Roll the balloon envelope Figure 36 upwards to expose the lamp Figure 36 Rolling up Balloon Envelope NOTICE do NoT use excessive force when zipping or unzipping the balloon The possibility exists of the zipper tearing which would make the balloon unusable ZIPPER BALLOON ENVELOPE 6 Release the lamp guard locking tabs Figure 37 Figure 37 Releasing Lamp Guard Locking Tabs 7 Remove lamp guard Figure 38 Figure 38 Lamp Guard Removal 8 Press tabs on the lamp holder and lift up holder to release lamp Remove lamp Figure 39 from lamp socket by turning lamp in a counterclockwise direction Figure 39 Removing Lamp LOCK TAB LAMP GUARD LOCK TAB LAMP GUARD LAMP HOLDER LAMP SOCKET page 28 gb12bw bs bp LIgHTINg sYsTeM operaTIoN aNd parTs MaNuaL rev 0 06 24 13 maintenanCe 9 Install replacement lamp Figure 40 into lamp socket and turn lamp in a clockwise direction until tight Press tabs on the lamp holder and slowly bring down the holder to secur
11. 47 Figure 47 Locking Air Plate LOCK TAB page 30 gb12bw bs bp LIgHTINg sYsTeM operaTIoN aNd parTs MaNuaL rev 0 06 24 13 maintenanCe B4 L3 B3 L2 L1 E2 T4 T2 E1 B2 B2 T1 P2 P3 P4 P1 B1 B2 E1 GB12BW B2 E2 E1 B1 B2 GB12BP B1 E2 Figure 48 Maintenance Check Points gb12bw bs bp LIgHTINg sYsTeM operaTIoN aNd parTs MaNuaL rev 0 06 24 13 page 31 maintenanCe For a prolonged life cycle an extended quality follow the recommended GloBug lighting system service guidelines as referenced in Figure 48 and Table 6 Table 5 periodic Check and Maintenance Figure part Check Item solution Lamp L1 Lamp Base Lamp base loose Screw in securely v L2 Pipe Frame Frame pipe skewed Replace v L3 Lamp Defective lamp Replace n Balloon B1 Balloon Envelope Defective or dirty Replace v B2 Zipper Broken Replace v B3 Fan Motor Blower Not working properly Repair or replace v B4 T Handle bolt Balloon Broken Replace v Electric E1 Power Cable Defective or worn cable Replace v E2 Plug Damaged Replace v Tripod T1 Tripod Damaged or not working properly Replace n T2 Mast Damaged or not working properly Replace v T3 Latch Damaged Replace v T4 T Handle bolt Mast Damaged Replace v Pole P1 Clamp Broken Replace v P2 Offset pole Offset pole bent or damaged Repl
12. 5 0013112040 BOLT M12x40 1 6 0033112000 NUT M12 1 7 A000028100 POLE MOUNT KIT 1 INCLUDES ITEMS W CONTACT MQ UNIT SALES offset Pole assy Gb12bs page 50 gb12bw bs bp LIgHTINg sYsTeM operaTIoN aNd parTs MaNuaL rev 0 06 24 13 terms anD ConDitions of sale Parts paYMeNT TerMs Terms of payment for parts are net 30 days FreIgHT poLICY All parts orders will be shipped collect or prepaid with the charges added to the invoice All shipments are F O B point of origin Multiquip s responsibility ceases when a signed manifest has been obtained from the carrier and any claim for shortage or damage must be settled between the consignee and the carrier MINIMuM order The minimum charge for orders from Multiquip is 15 00 net Customers will be asked for instructions regarding handling of orders not meeting this requirement reTurNed goods poLICY Return shipments will be accepted and credit will be allowed subject to the following provisions 1 A Returned Material Authorization must be approved by Multiquip prior to shipment 2 To obtain a Return Material Authorization a list must be provided to Multiquip Parts Sales that defi nes item numbers quantities and descriptions of the items to be returned a The parts numbers and descriptions must match the current parts price list b The list must be typed or computer
13. 560 mm C 7 5 in 190 mm H 23 6 in 600 mm D 49 5 in 1 258 mm I 79 2 111 in 1910 2820 mm E 51 2 in 1 300 mm J 90 4 126 2 in 2295 3205 mm Figure 1 Dimensions GB12BW A B C D E F G H I J page 12 gb12bw bs bp LIgHTINg sYsTeM operaTIoN aNd parTs MaNuaL rev 0 06 24 13 Dimensions Gb12bs Figure 2 Dimensions GB12BS D A H I J G B E F BALLOON ASSEMBLY STRAIGHT POLE OFFSET POLE C Table 3 dimensions reference Letter dimension in mm reference Letter dimension in mm A 43 7 1110 F 16 7 425 B 33 4 850 G 39 3 1000 C 21 535 H 8 7 220 D 74 6 1895 I 7 8 200 E 26 8 683 J 23 6 600 gb12bw bs bp LIgHTINg sYsTeM operaTIoN aNd parTs MaNuaL rev 0 06 24 13 page 13 Dimensions Gb12bP Figure 3 Dimensions GB12BP B A Table 4 dimensions reference Letter dimension in mm A 23 6 in 600 mm B 33 0 in 850 mm page 14 gb12bw bs bp LIgHTINg sYsTeM operaTIoN aNd parTs MaNuaL rev 0 06 24 13 footCanDle Plot Figure 4 Floodlight Candle Plot BAL 85 Drum Shaped 300 Degree Coverage Scale Grid 50 ft 15 25 meters Values listed as footcandles 5 2 5 10 1 gb12bw bs bp LIgHTINg sYsTeM operaTIoN aNd parTs MaNuaL rev 0 06 24 13 page 15 General information The Multiquip GloBug GB12W GB12BS and GB12BP
14. To Change Effective January 1st 2006 NOTICE All orders are treated as Standard Orders and will ship the same day if received prior to 3PM PST page 6 gb12bw bs bp LIgHTINg sYsTeM operaTIoN aNd parTs MaNuaL rev 0 06 24 13 safety information Do not operate or service the equipment before reading the entire manual Safety precautions should be followed at all times when operating this equipment Failure to read and understand the safety messages and operating instructions could result in injury to yourself and others saFeTY Messages The four safety messages shown below will inform you about potential hazards that could injure you or others The safety messages specifi cally address the level of exposure to the operator and are preceded by one of four words daNger warNINg CauTIoN or NoTICe saFeTY sYMboLs daNger Indicates a hazardous situation which if not avoided WiLL result in deaTH or serIous INJurY warNINg Indicates a hazardous situation which if not avoided CouLd result in deaTH or serIous INJurY CauTIoN Indicates a hazardous situation which if not avoided CouLd result in MINor or ModeraTe INJurY NOTICE Addresses practices not related to personal injury Potential hazards associated with the operation of this equipment will be referenced with hazard symbols which may appear throughout this manual in conjunction with safety messages gb12bw bs bp LIgHTINg sYsTeM oper
15. e n o olla b sI e p ole v n e n o olla b e c alp e r ro ria p e R G N IT O O H S E L B U O R T T S A M 8 E L B A T M O T P M Y S M E L B O R P E L B I S S O P N O IT U L O S e b to n n a c ts a M d e sia r d e k c olre v e L k c o L ts a M sI re v e L k c o L ts a M e s a ele R e b to n n a c ts a m e h T d e re w ol d e k c olre v e L k c o L ts a M sI re v e L k c o L ts a M e s a ele R page 34 gb12bw bs bp LIgHTINg sYsTeM operaTIoN aNd parTs MaNuaL rev 0 06 24 13 exPlanation of CoDe in remarks Column The following section explains the different symbols and remarks used in the Parts section of this manual Use the help numbers found on the back page of the manual if there are any questions Sample partS liSt NO part NO part Name QtY remarKS 1 12345 BOLT 1 INCLUDES ITEMS W 2 WASHER 1 4 IN NOT SOLD SEPARATELY 2 12347 WASHER 3 8 IN 1 MQ 45T ONLY 3 12348 HOSE A R MAKE LOCALLY 4 12349 BEARING 1 S N 2345B AND ABOVE NO Column Unique Symbols All items with same unique symbol or gt in the number column belong to the same assembly or kit which is indicated by a note in the Remarks column Duplicate
16. has been selected for the job See Cable Selection Chart in this manual page 10 gb12bw bs bp LIgHTINg sYsTeM operaTIoN aNd parTs MaNuaL rev 0 06 24 13 sPeCifiCations Table 1 specifications globug Lighting system Model GB12BW BS BP Input Voltage 90 130 170 240 VAC Ballast Electronic Ballast 50Hz 60Hz Frequency 50 Hz 60 Hz Single Phase Max Current 3 8 Amps Lamp Lamp Type 400 Watt Metal Halide Lumens 34 200 Light Coverage 360 90 ft 27 4 meters Surface Temperature Longitudinal 476 6 F 247 C Max Surface Temperature Transversal 417 2 F 214 C Max Fan Motor Balloon Fan Motor 24 VDC Max Current 1 2 A Pressure 0 324 kPA 0 047 psi balloon Diameter 33 in 850 mm Material Polyester Heat Resisting Temperature 320 356 F 160 180 C Melting Temperature 500 F 260 C Internal Temperature of Balloon 126 F 52 C Average Water Resistance 1 500 mm H20 Mast gb12bw Number of Stages 2 Maximum Height Standard Extension Pole 10 feet 3 meters 13 feet 4 meters gb12bw bs bp LIgHTINg sYsTeM operaTIoN aNd parTs MaNuaL rev 0 06 24 13 page 11 Dimensions Gb12bW Table 2 dimensions reference Letter dimension in mm reference Letter dimension in mm A Upper Position 44 7 in 1 135 mm Lower Position 52 4 in 1 330 mm F 33 5 in 850 mm B Upper Position 52 2 in 1 325 mm Lower Position 62 0 in 1 575 mm G 22 in
17. the sender at his expense 9 Credit on returned parts will be issued at dealer net price at time of the original purchase less a 15 restocking charge 10 In cases where an item is accepted for which the original purchase document can not be determined the price will be based on the list price that was effective twelve months prior to the RMA date 11 Credit issued will be applied to future purchases only prICINg aNd rebaTes Prices are subject to change without prior notice Price changes are effective on a specifi c date and all orders received on or after that date will be billed at the revised price Rebates for price declines and added charges for price increases will not be made for stock on hand at the time of any price change Multiquip reserves the right to quote and sell direct to Government agencies and to Original Equipment Manufacturer accounts who use our products as integral parts of their own products speCIaL eXpedITINg servICe A 35 00 surcharge will be added to the invoice for special handling including bus shipments insured parcel post or in cases where Multiquip must personally deliver the parts to the carrier LIMITaTIoNs oF seLLer s LIabILITY Multiquip shall not be liable hereunder for damages in excess of the purchase price of the item with respect to which damages are claimed and in no event shall Multiquip be liable for loss of profi t or good will or for any other special consequ
18. time for the lamp to cool before changing The possibility exists of severe burns CauTIoN Never use force when installing the lamp Excessive force could cause the lamp to break causing bodily harm NOTICE Never leave any grease or oil residue on lamp surface when replacing or removing lamp This can create hot spots reducing the service life of the lamp ALWAYS make sure lamp surface is clean and dry ALWAYS replace with MQ recommended type lamp See parts section of this manual If applicable ALWAYS make sure the lamp guard is installed correctly Never deform the lamp guard Never unplug the lamp s AC power cable during operation ALWAYS have a trained technician to install and remove lamp or replace any damaged fi xture wiring TraNsporTINg saFeTY NOTICE When transporting the tripod lighting system if applicable always place in stow position and place tripod in its carrying case ALWAYS remove balloon lamp assembly from the mast when transporting lighting system This will prevent damage to the bulb due to vibration Never leave the balloon lamp exposed during transport Exposure to excess wind or rain could damage the balloon s nylon cover ALWAYS place balloon inside its protective cover during transport Be sure the cover is secured tightly around the balloon lamp assembly gb12bw bs bp LIgHTINg sYsTeM operaTIoN aNd parTs MaNuaL rev
19. 06 24 13 page 39 No parT No parT NaMe QTY reMarKs 1 A400193300 DECAL GLOBUG LIGHTING SYSTEM 1 2 A400323800 DECAL GLOBUG INFO ELECTRIC SHOCK FRENCH 1 2A A400204701 DECAL GLOBUG INFO ELECTRIC SHOCK ENGLISH 1 3 A400326300 DECAL LAMP TYPE 1 4 A400290900 DECAL CAUTION LAMP INFORMATION ENGLISH 1 5 A400324200 DECAL CAUTION LAMP INFORMATION FRENCH 1 6 A400084300 DECAL GROUND 2 7 A400323900 DECAL LIGHT CONTROL SWITCH 1 8 NAMEPLATE 1 CONTACT MQ PARTS DEPT 9 A400325000 DECAL CAUTION AC ONLY 1 10 A400325100 DECAL ELECTRIC SHOCK HIGH VOLTAGE BURN HAZ 1 11 A400206000 DECAL DIMMER SWITCH 1 namePlate anD DeCals Gb12bs page 40 gb12bw bs bp LIgHTINg sYsTeM operaTIoN aNd parTs MaNuaL rev 0 06 24 13 namePlate anD DeCals Gb12bP 12 10 9 2 3 1 4 11 16 MODEL SERIAL NO gb12bw bs bp LIgHTINg sYsTeM operaTIoN aNd parTs MaNuaL rev 0 06 24 13 page 41 namePlate anD DeCals Gb12bP No parT No parT NaMe QTY reMarKs 1 A400326300 DECAL LAMP TYPE 1 2 A400290900 DECAL CAUTION LAMP INFORMATION ENGLISH 1 3 A400324200 DECAL CAUTION LAMP INFORMATION FRENCH 1 4 A400084300 DECAL GROUND 2 5 A400323900 DECAL LIGHT CONTROL SWITCH 1 6 NAMEPLATE 1 CONTACT MQ PARTS D
20. AST UPPER T HANDLE PROTECTIVE COVER LOWER T HANDLE VELCRO TAB 3 Next fold the protective cover Figure 13 into itself and zip Figure 13 Folding Protective Cover 4 Attach the S type hook Figure 14 on the AC power cable onto the washer eylet located on the bottom plate of the light assembly Figure 14 Securing Power Cord ZIPPER PROTECTIVE COVER S TYPE HOOK WASHER EYELET BOTTOM PLATE page 20 gb12bw bs bp LIgHTINg sYsTeM operaTIoN aNd parTs MaNuaL rev 0 06 24 13 raIsINg THe MasT gb12bw 1 Before raising the mast make sure the upper T handle bolt lock Figure 15 is securely tightened This will prevent the balloon lamp assembly from falling off In addition make sure that the lamp power cable is connected to the mating end of the 15 ft 4 5 meters power source cable daNger ALWAYS make sure the area above the lighting system is open and clear of overhead power lines and other obstructions The mast extends in excess of 13 ft 4 meters when an optional extension is used Contact with overhead power lines or other obstructions could result in equipment damage serious Injury or death CauTIoN When raising mast ALWAYS be on the lookout for overhead obstructions such as high voltage power lines The possibility exists of electrocution even death if the lighting system comes in contact with high voltage power lines daNger When raising mast ALWAYS be o
21. EPT 7 A400325000 DECAL CAUTION AC ONLY 1 8 A400325100 DECAL ELECTRIC SHOCK HIGH VOLTAGE BURN HAZ 1 9 A400206000 DECAL DIMMER SWITCH 1 page 42 gb12bw bs bp LIgHTINg sYsTeM operaTIoN aNd parTs MaNuaL rev 0 06 24 13 mast triPoD assy 1 8 11 13 13 14 17 23 27 5 15 16 9 20 19 18 10 12 2 7 26 16 16 24 6 4 6 3 21 22 25 gb12bw bs bp LIgHTINg sYsTeM operaTIoN aNd parTs MaNuaL rev 0 06 24 13 page 43 mast triPoD assy No parT No parT NaMe QTY reMarKs 1 A300131500 TRIPOD COVER 1 2 A300106500 TRIPOD BAND 1 3 A300108700 SHACKLE CP 1 4 A300199600 BASE PIPE 2 1 5 A300199500 BASE PIPE 1 1 6 1641000330 RUBBER FOOT 3 7 2212780310 LEVER 1 8 A300200600 SECOND MAST ASSY 1 9 A300200300 FIRST MAST ASSY 1 10 A400187600 KNOB 1 11 A400229900 BOTTOM PLATE 1 12 0024705008 SET SCREW M5x8 2 13 A400200500 WASHER SECOND MAST 1 14 A400200700 RUBBER MAST 1 15 A400110200 WASHER MAST 1 16 0043108000 WASHER M8 3 17 0013108030 BOLT M8x30 1 18 A400112700 LEAF VALVE 1 19 0023104008 SCREW M4x8 1 20 0043104000 WASHER M4 1 21 0023105008 SCREW M5x8 1 22 0043105000 WASHER M5 1 23 A400199700 PLUG 1 24 A300171601 PIPE BASE 3 25 A300113103 STAY 3 26 A400205901 SPRING SHACKLE 1 27 0033206000 SELFLOCK NUT M8 1 page 44 gb12bw bs bp LIgHTINg sYsTe
22. M operaTIoN aNd parTs MaNuaL rev 0 06 24 13 fan bloWer lamP assy 18 20 21 35 11 43 22 12 37 44 41 45 16 26 19 22 22 38 40 22 25 25 39 27 28 29 31 30 33 32 34 gb12bw bs bp LIgHTINg sYsTeM operaTIoN aNd parTs MaNuaL rev 0 06 24 13 page 45 fan bloWer lamP assy No parT No parT NaMe QTY reMarKs 11 A300275800 ELE BALLAST ASSY 1 12 2214500230 SEAL FLAT 1 16 A300162400 SEAL PACKING 1 18 A300264500 FAN MOTOR ASSY 1 19 0023304012 SCREW amp WASHER M4x12 4 20 0023204006 SCREW M4x6 3 21 A300164900 PLATE FAN 1 22 0024304008 SCREW M4x8 9 25 0033104000 NUT M4 5 26 A300145801 PLATE BOTTOM 1 27 A400030700 STOPPER FILTER 3 28 E000119300 WAVE WASHER M6 3 29 E000077500 SPACER 3 30 A200057603 FLANGE 1 31 E000114400 SPACER 4 32 A300181901 POWER CABLE 1 33 A300269500 SWITCH CP 1 34 A300180500 VESSEL 1 1 35 A300180600 VESSEL 2 1 37 A300148200 SHEET BOTTOM 1 38 0014710035 BUTTON SCREW M10x35 4 39 0043210000 SPRING WASHER M10 8 40 2204510110 WASHER 1 41 0043110000 WASHER M10 3 43 A400209801 KNOB KSM 50 M10x30 1 44 A300174401 FILTER 1 45 A300175300 PLATE AIR 1 page 46 gb12bw bs bp LIgHTINg sYsTeM operaTIoN aNd parTs MaNuaL rev 0 06 24 13 balloon lamP GuarD assy 36 46 15 39 41 17 42 16 14 13 12
23. OperatiOn and parts Manual THIS MANUAL MUST ACCOMPANY THE EQUIPMENT AT ALL TIMES To find the latest revision of this publication visit our website at www multiquip com GloBug series MOdels GB12BW SERIAL NO G2700001 AND ABOVE GB12Bs SERIAL NO G2800001 AND ABOVE GB12Bp SERIAL NO G2900001 AND ABOVE Revision 0 06 24 13 page 2 gb12bw bs bp LIgHTINg sYsTeM operaTIoN aNd parTs MaNuaL rev 0 06 24 13 notes gb12bw bs bp LIgHTINg sYsTeM operaTIoN aNd parTs MaNuaL rev 0 06 24 13 page 3 page 4 gb12bw bs bp LIgHTINg sYsTeM operaTIoN aNd parTs MaNuaL rev 0 06 24 13 table of Contents Gb12bW bs bP lighting system Table Of Contents 4 Parts Ordering Procedures 5 Safety Information 6 9 Specifications 10 Dimensions GB12BW 11 Dimensions GB12BS 12 Dimensions GB12BP 13 Footcandle Plot 14 General Information 15 Components 16 17 Setup GB12BW 18 20 Operation GB12BW
24. aTIoN aNd parTs MaNuaL rev 0 06 24 13 page 7 safety information geNeraL saFeTY CauTIoN Never operate this equipment without proper protective clothing shatterproof glasses respiratory protection hearing protection steel toed boots and other protective devices required by the job or city and state regulations Never operate this equipment when not feeling well due to fatigue illness or when under medication Never operate this equipment under the infl uence of drugs or alcohol ALWAYS check the equipment for loosened threads or bolts before starting do NoT use the equipment for any purpose other than its intended purposes or applications NOTICE This equipment should only be operated by trained and qualifi ed personnel 18 years of age and older Whenever necessary replace nameplate operation and safety decals when they become diffi cult read Manufacturer does not assume responsibility for any accident due to equipment modifi cations Unauthorized equipment modifi cation will void all warranties Never use accessories or attachments that are not recommended by Multiquip for this equipment Damage to the equipment and or injury to user may result ALWAYS know the location of the nearest fi re extinguisher ALWAYS know the location of the nearest fi rst aid kit ALWAYS know the location of the nearest phone or keep a phone on the job site Also
25. ace v P3 Knob Loose Tighten securely v P4 Straight pole Straight pole bent or damaged Replace v v Daily Check n Every 20 Hours page 32 gb12bw bs bp LIgHTINg sYsTeM operaTIoN aNd parTs MaNuaL rev 0 06 24 13 WirinG DiaGram Figure 49 Electrical Wiring Diagram GRN YEL Switch J1 S1 Dimming SW SW2 L1 M1 SW1 C1 GRN YEL BLACK BLACK BLACK RED RED RED BLACK BLACK WHITE WHITE WHITE WHITE WHITE Table 6 reference designations on electrical wiring diagram reference designator description part Number J1 Cable CP A300181901 C1 E Ballast A300275800 S1 Socket Assy A300273200 L1 Lamp 400 W E000125500 SW1 ON OFF Switch A300269500 SW2 Dimming Switch N A included with C1 gb12bw bs bp LIgHTINg sYsTeM operaTIoN aNd parTs MaNuaL rev 0 06 24 13 page 33 troubleshootinG Practically all breakdowns can be prevented by proper handling and maintenance inspections but in the event of a breakdown please take a remedial action following the diagnosis based on the Lamp Troubleshooting Table 7 and Mast Troubleshooting Table 8 information shown below If the problem cannot be remedied please leave the unit just as it is and consult or company s service department G N IT O O H S E L B U O R T P M A L 7 E L B A T M O T P M Y S M E L B O R P E L B I S S O P N O IT U L O S th gilto
26. are general purpose portable glare free lighting systems Typical applications for these types of lighting systems include construction sites emergency road crews and backyard parties baLLooN eNveLopes The GloBug lighting system can be configured with a variety of balloon envelopes canopy Please contact the MQ sales department for the balloon of your choice The GloBug GB12BW GB12BS and GB12BP are shipped from the factory with the drum type balloon Lighting Multiquip s GloBug lighting system is comprised of one Metal Halide 400 watt lamp This lamp has an output of 34 200 lumens Typical lighting coverage is in excess of 90 feet 27 meters in a 360 degree pattern power These GloBug lighting systems are powered by a light weight electronic ballast that is built inside the lamp housing The input power requirements for operating the lighting system is 120 VAC 60 Hz 4 5 amps seTup gb12bw The GB12BW lighting system can be setup quickly and easily Tripod legs can be deployed in one quick easy step and can be adjusted to two different heights The upper position will add an additional foot to the mast height If desired an optional 35 inch 900 mm extension pole can be added to the mast height Please contact the MQ sales department if you wish to add this feature to your system In addition the unit is equipped with an air assist mast lowering system This system allows the mast to be retracted slowly so that the mast will not
27. assembly is used to prevent the lighting system from falling off which can cause injury or equipment damage STRAIGHT POLE OFFSET POLE KNOB BOLT warNINg Always securely tighten the knob on the offset or the bolt on the straight pole when assembly is used to prevent the lighting system from falling off which can cause injury or equipment damage gb12bw bs bp LIgHTINg sYsTeM operaTIoN aNd parTs MaNuaL rev 0 06 24 13 page 25 reMovINg THe proTeCTIve CoverINg gb12bs 1 Expose the balloon by pulling down on the velcro tab and unzipping the protective cover as shown in Figure 31 Figure 31 Removing Balloon AC Power Cord 2 Next fold the protective cover Figure 32 into itself and zip Figure 32 Folding Protective Cover VELCRO TAB PROTECTIVE COVER ZIPPER PROTECTIVE COVER setuP Gb12bs 3 Attach both S type hooks Figure 33 on the AC power cable into the cable support holes on the offset pole Figure 33 Attachment of S Hooks B OFFSET POLE S TYPE HOOK POWER CABLE page 26 gb12bw bs bp LIgHTINg sYsTeM operaTIoN aNd parTs MaNuaL rev 0 06 24 13 oPeration Gb12bs raIsINg THe MasT gb12bs 1 Before raising the mast make sure the T handle bolt lock is securely tightened This will prevent the balloon lamp assembly from falling off 2 Raise extension pole to desired height Watch out for any overhead obstructions 3 Tighten extension clamp bolt se
28. curely daNger ALWAYS make sure the area above the lighting system is open and clear of overhead power lines and other obstructions The mast extends in excess of 13 ft 4 meters when an optional extension is used Contact with overhead power lines or other obstructions could result in equipment damage serious Injury or death daNger When raising mast ALWAYS be on the lookout for overhead obstructions such as high voltage power lines The possibility exists of electrocution even death if the lighting system comes in contact with high voltage power lines appLYINg power gb12bs 1 If using a portable generator start the generator as referenced in the Start up Section of the supplied generator manual 2 Once the generator has started plug the AC power cord from the lamp into a GFCI receptacle on the generator 3 If using a power source Figure 34 other than a portable generator plug the AC power cord from the lamp into a 120 VAC 60 Hz receptacle that is protected by a at least a 15 amp circuit breaker Figure 34 120 VAC Receptacle EXTERNAL SINGLE PHASE 120 VAC POWER SOURCE POWER CABLE RECEPTACLE NOTICE Refer to previous sections on Applying Power GB12BW Dimming the Lamp and Shutdown for procedures in operating the lamp gb12bw bs bp LIgHTINg sYsTeM operaTIoN aNd parTs MaNuaL rev 0 06 24 13 page 27 maintenanCe repLaCINg THe LaMp 1 Allow lamp Figure 35 15
29. e lamp in place Figure 40 Installing Lamp repLaCINg baLLooN eNveLope 1 Unzip the zipper Figure 38 at the top and bottom of the balloon envelope cover Figure 41 Unzipping the Balloon Envelope 2 Slide the old or worn balloon envelope Figure 42 over the top of the lamp guard assembly Figure 42 Removing the Balloon Envelope LAMP SOCKET BALLOON ENVELOPE TOP ZIPPER BOTTOM ZIPPER BALLOON ENVELOPE LAMP GUARD 3 Slide the new balloon Figure 43 envelope over the top of the lamp guard assembly Figure 43 Installing New Balloon Envelope 4 Zip up the zipper Figure 44 at the top and bottom of the balloon envelope cover Figure 44 Zipping the Balloon Envelope BALLOON ENVELOPE LAMP GUARD BALLOON ENVELOPE TOP ZIPPER BOTTOM ZIPPER gb12bw bs bp LIgHTINg sYsTeM operaTIoN aNd parTs MaNuaL rev 0 06 24 13 page 29 FILTer repLaCeMeNT 1 Remove the balloon as described in the STORAGE section 2 Turn the balloon lamp assembly upsidedown to access the filter See Figure 45 Figure 45 Accessing Filter 3 Turn the three locking tabs outwards to release the air plate See Figure 45 4 Remove the air plate and filter See Figure 46 Figure 46 Filter Removal 5 Install a new filter and reinstall the air plate AIR PLATE LOCKING TAB AIR PLATE FILTER maintenanCe 6 Turn the three locking tabs inwards to lock the air plate in place See Figure
30. ential or incidental damages LIMITaTIoN oF warraNTIes No warranties express or implied are made in connection with the sale of parts or trade accessories nor as to any engine not manufactured by Multiquip Such warranties made in connection with the sale of new complete units are made exclusively by a statement of warranty packaged with such units and Multiquip neither assumes nor authorizes any person to assume for it any other obligation or liability whatever in connection with the sale of its products Apart from such written statement of warranty there are no warranties express implied or statutory which extend beyond the description of the products on the face hereof Effective February 22 2006 gb12bw bs bp LIgHTINg sYsTeM operaTIoN aNd parTs MaNuaL rev 0 06 24 13 page 51 notes OperatiOn and parts Manual Your Local Dealer is HERE S HOW TO GET HELP PLEASE HAVE THE MODEL AND SERIAL NUMBER ON HAND WHEN CALLING United StateS Multiquip Corporate Office MQ Parts Department 18910 Wilmington Ave Carson CA 90746 Contact mq multiquip com Tel 800 421 1244 Fax 310 537 3927 800 427 1244 310 537 3700 Fax 800 672 7877 Fax 310 637 3284 Service Department Warranty Department 800 421 1244 310 537 3700 Fax 310 537 4259 800 421 1244 310 537 3700 Fax 310 943 2249 Technical Assistance 800 478 1244 Fax 310 943 2238 mexico United Kingdom MQ Cipsa Multiquip UK Limi
31. fall rapidly when released This feature reduces the amount of vibration or shock to the lamp seTup gb12bs The GB12BS lighting system offset pole is designed to be attached to a external piece of a equipment such as a paver Figure 5 This system is equally easy to assemble Simply attach the supplied support clamps to an external pole or support and you are ready gB12BP When only a complete lamp assembly is required please order Model GB12BP This model number includes the lamp protective guard balloon protective covering and all other components that make up the lamp assembly Figure 5 GB12BS Attachment Paver TraNsporT The GB12BW lighting system can be transported Figure 6 quite easily in two carrying cases The first case tripod weighs 16 lbs 7 25 kg and the second case lamp assembly weighs 15 lbs 6 8 kg for a combined weight of about 31 lbs 14 kg For ease of service or transport the lamp assembly is equipped with a quick disconnect connector that allows the lamp fixture to be removed quickly This feature is extremely useful during transport of the lighting system It is always best to remove the lamp and pack it safely so it will not be damaged Figure 6 GB12BW Transporting TRIPOD CARRYING CASE LIGHT ASSEMBLY CARRYING CASE page 16 gb12bw bs bp LIgHTINg sYsTeM operaTIoN aNd parTs MaNuaL rev 0 06 24 13 ComPonents Figure 7 Major Components 11 2 4 5 6 8
32. g handle counterclockwise Figure 20 Push down on mast until mast is fully inserted into mast housing Tighten T handle fully Figure 20 Lowering the Mast 2 Unzip the zipper on the protective cover Figure 20 and pull down cover over balloon lamp assembly Figure 21 Unzipping the Protective Cover 3 Unhook lamp AC power cable from washer eyelet Figure 14 Fully zip protective cover and fold velcro tab in place Figure 22 LOWER T HANDLE ZIPPER PROTECTIVE COVER oPeration Gb12bW Figure 22 Zipping the Protective Cover 4 Loosen upper T handle by turning counterclockwise and lift lamp assembly from mast 5 Store lamp assembly enclosed with its protective cover Figure 23 in a safe location where it will not be damaged Figure 23 Storing Lamp Assembly 6 To retract tripod legs Figure 24 and place in the stow position lift up on mast while pulling up on the velcro strap Continue pulling upward on the mast until the tripod legs are fully retracted and are in the stow position Figure 24 Retracting Tripod Legs VELCRO TAB AC POWER CABLE PROTECTIVE COVER PROTECTIVE COVER LATCH UPPER LOWER MAST gb12bw bs bp LIgHTINg sYsTeM operaTIoN aNd parTs MaNuaL rev 0 06 24 13 page 23 7 Once tripod legs are in the stow position place velcro strap Figure 25 around all three tripod legs Secure tripod legs by inserting the male and female connector ends of the stra
33. gHTINg sYsTeM operaTIoN aNd parTs MaNuaL rev 0 06 24 13 setuP Gb12bW TrIpod depLoYMeNT gb12bw 1 Place the tripod on a firm level surface so that it will not slide or turn over Make sure there is enough space around the unit for the tripod legs to be deployed 2 Remove tripod from its carrying case The tripod legs are secured by a black velcro strap Figure 8 Squeeze both tabs on each side of buckle to unlock strap and allow tripod legs Figure 9 to be deployed Figure 8 Velcro Strap Open SQUEEZE VELCRO STRAP BUCKLE TRIPOD LEGS Figure 9 Tripod Deployment 3 Next pull upward on the mast and let the tripod legs deploy Once the tripod legs have been fully deployed make sure the legs are locked by securing the latch The latch Figure 10 has two positions upper and lower Placing the latch in the upper position will provide 1 ft 305 mm more height Figure 10 Securing the Tripod DEPLOYMENT LATCH UPPER LOWER MAST gb12bw bs bp LIgHTINg sYsTeM operaTIoN aNd parTs MaNuaL rev 0 06 24 13 page 19 setuP Gb12bW baLLooN asseMbLY pLaCeMeNT gb12bw 1 Place balloon assembly Figure 11 onto mast and tighten Upper T handle Figure 11 Light Asembly Placement 2 Expose the balloon by pulling down on the velcro tab and unzip the protective cover as shown in Figure 12 Also remove the AC power cord at this time Figure 12 Removing Balloon AC Power Cord M
34. generated c The list must state the reason s for the return d The list must reference the sales order s or invoice s under which the items were originally purchased e The list must include the name and phone number of the person requesting the RMA 3 A copy of the Return Material Authorization must accompany the return shipment 4 Freight is at the sender s expense All parts must be returned freight prepaid to Multiquip s designated receiving point 5 Parts must be in new and resalable condition in the original Multiquip package if any and with Multiquip part numbers clearly marked 6 The following items are not returnable a Obsolete parts If an item is in the price book and shows as being replaced by another item it is obsolete b Any parts with a limited shelf life such as gaskets seals O rings and other rubber parts that were purchased more than six months prior to the return date c Any line item with an extended dealer net price of less than 5 00 d Special order items e Electrical components f Paint chemicals and lubricants g Decals and paper products h Items purchased in kits 7 The sender will be notifi ed of any material received that is not acceptable 8 Such material will be held for five working days from notifi cation pending instructions If a reply is not received within five days the material will be returned to
35. ghtly Figure 19 The LED will blink The lamp should dim to about 75 brightness Figure 19 Dimmer Switch 3 To turn back the lamp to its original brightness press the dimmer switch again The LED will turn off 4 Tor turn off the lamp while keeping the balloon inflated press and hold the dimmer switch for three seconds The LED will light red 5 Zip up the bottom of the balloon completely after use of the dimmer switch sHuTdowN 1 Turn off the power switch of the generator 2 Turn off the Power oN oFF switch The balloon should start to deflate and the lamp will turn off 3 Disconnect the AC power cable from the generator 0 1 DIMMER SWITCH NOTICE To turn on lamp again after it was turned off with the dimmer switch turn off the Power oN oFF switch Wait three to five minutes then turn the oN oFF switch back on The lamp will now light back to 100 brightness NOTICE If the power cable is accidentally unplugged from the power source wait three to five minutes before reconnecting the power This will allow time for the fan to reset and ensure balloon will inflate properly when power is reconnected CauTIoN Allow a sufficient amount of time 15 20 minutes for the lamp to cool down The possibility exists of the balloon getting burned touching the lamp page 22 gb12bw bs bp LIgHTINg sYsTeM operaTIoN aNd parTs MaNuaL rev 0 06 24 13 sTorage 1 Loosen the lower T handle by turnin
36. han billing address return Fax Number applicable Model Number Quantity part Number and description of each part specify preferred Method of shipment UPS Fed Ex DHL n Priority One Truck n Ground n Next Day n Second Third Day If you have an MQ Account to obtain a Username and Password E mail us at parts multiquip com To obtain an MQ Account contact your District Sales Manager for more information order via Internet dealers only Order parts on line using Multiquip s SmartEquip website n View Parts Diagrams n Order Parts n Print Specifi cation Information Note Discounts Are Subject To Change Goto www multiquip com and click on Order Parts to log in and save Use the internet and qualify for a 5 discount on Standard orders for all orders which include complete part numbers order via Fax dealers only All customers are welcome to order parts via Fax domestic us Customers dial 1 800 6 PARTS 7 800 672 7877 Fax your order in and qualify for a 2 discount on Standard orders for all orders which include complete part numbers order via phone domestic us dealers Call 1 800 427 1244 best deal International Customers should contact their local Multiquip Representatives for Parts Ordering information Non dealer Customers Contact your local Multiquip Dealer for parts or call 800 427 1244 for help in locating a dealer near you Note Discounts Are Subject
37. ipod legs are fully deployed To place tripod legs in the stow position pull upward on velcro strap while pushing down on tripod pole Pull all legs upward and secure with velcro strap 8 Lamp guard This guard cage protects the lamp from being hit by objects 9 Lamp 400 watt metal halide type lamp Replace only with MQ recommended type lamp Always allow a sufficient amount of time for the lamp to cool down before changing 10 Fan Motor blower This electric motor is responsible for inflating the balloon It will supply a pressure of 0 6 inch H20 0217 psi 0 149 kPA Please note that the balloon will begin to inflate as soon as power is applied to the lighting system 11 Tripod Carrying Case Use this case when transporting of the tripod is required ALWAYS store tripod in this carrying case when not in use 12 weight support Hook To add additional weight to the tripod and make the tripod more stable in windy conditions Place a sandbag or similar weight onto this hook 13 offset pole Supports lamp assembly when attached to the straight pole 14 Knob Secures the offset pole to the straight pole when tightened 15 straight pole Used in conjunction with the offset pole to support the lamp assembly 16 Clamps Used to attach the straight pole to an external support These clamps must be tightened securely to prevent the light assembly from falling off page 18 gb12bw bs bp LI
38. item Numbers Duplicate numbers indicate multiple part numbers which are in effect for the same general item such as different size saw blade guards in use or a part that has been updated on newer versions of the same machine part NO Column Numbers Used Part numbers can be indicated by a number a blank entry or TBD TBD To Be Determined is generally used to show a part that has not been assigned a formal part number at the time of publication A blank entry generally indicates that the item is not sold separately or is not sold by Multiquip Other entries will be clarified in the Remarks Column NOTICE The contents and part numbers listed in the parts section are subject to change without notice Multiquip does not guarantee the availability of the parts listed NOTICE When ordering a part that has more than one item number listed check the remarks column for help in determining the proper part to order QtY Column Numbers Used Item quantity can be indicated by a number a blank entry or A R A R As Required is generally used for hoses or other parts that are sold in bulk and cut to length A blank entry generally indicates that the item is not sold separately Other entries will be clarified in the Remarks Column remarKS Column Some of the most common notes found in the Remarks Column are listed below Other additional notes needed to describe the item can also be shown
39. n the lookout for overhead obstructions such as high voltage power lines The possibility exists of electrocution even death if the lighting system comes in contact with high voltage power lines setuP Gb12bW 2 To improve stability and to prevent tipping of the light unit place sand bags or similar type weight over the tripod legs or weight hook as shown in Figure 15 Figure 15 Sand Bags 3 Raise mast to desired height and tighten lower T handle Figure 15 securely SAND BAGS MAST RAISE LOWER T HANDLE UPPER T HANDLE WEIGHT HOOK gb12bw bs bp LIgHTINg sYsTeM operaTIoN aNd parTs MaNuaL rev 0 06 24 13 page 21 oPeration Gb12bW appLYINg power gb12bw 1 Before applying power make sure that the Power oN oFF switch Figure 16 is in the OFF position Figure 16 ON OFF Switch 2 Connect the AC power cable to the 120 VAC receptacle on the generator used See Figure 17 Figure 17 Connecting to Power Source 3 Start the generator as indicated in the generator manual 4 Turn on the Power oN oFF switch Figure 16 The balloon will start to inflate and the lamp will turn on dIMMINg THe LaMp 1 Slightly unzip the bottom of the balloon to gain access to the dimmer switch Figure 18 Figure 18 Unzipping Balloon 0 1 POWER ON OFF SWITCH 20A 120V 120 VAC RECEPTACLE POWER CABLE TYPICAL GENERATOR FRONT PANEL ZIPPER BALLOON 2 Press the dimmer switch li
40. p into each other Figure 25 Velcro Strap Closed 8 Place tripod Figure 26 inside protective carrying case Figure 26 Carrying Case VELCRO STRAP BUCKLE TRIPOD LEGS CLICK TRIPOD PROTECTIVE CARRYING CASE oPeration Gb12bW page 24 gb12bw bs bp LIgHTINg sYsTeM operaTIoN aNd parTs MaNuaL rev 0 06 24 13 setuP Gb12bs poLe seTup gb12bs 1 Attach one of the clamps that come with the GBS to the external support pole The clamps may be attached to vertical horizontal or angled pole See Figure 27 Figure 27 Clamp Attachment 2 Using a 19 mm wrench tighten the locknut securely See Figure 11 3 Attach the other clamp to the external support pole about 7 inches 140 mm lower than the previously installed clamp See Figure 28 If using horizontal external support poles a second pole is needed Figure 28 Distance Between Clamps LOCKNUT LOCKNUT VERTICAL EXTERNAL SUPPORT POLE ANGLED EXTERNAL SUPPORT POLE CLAMP CLAMP HORIZONTAL EXTERNAL SUPPORT POLE 7 0 INCHES 140 MM 4 Attach the straight pole to the clamps Tighten locknuts on both clamps See Figure 29 Figure 29 Straight Pole Attachment 5 Place the offset pole or an optional straight pole if desired on top of the straight pole Tighten knob or bolt securely See Figure 30 Figure 30 Offset Pole Attachment CLAMPS STRAIGHT POLE warNINg Always securely tighten the locknuts when
41. ted Head Office Carr Fed Mexico Puebla KM 126 5 Momoxpan Cholula Puebla 72760 Mexico Contact pmastretta cipsa com mx Tel 52 222 225 9900 Fax 52 222 285 0420 Unit 2 Northpoint Industrial Estate Globe Lane Dukinfield Cheshire SK16 4UJ Contact sales multiquip co uk Tel 0161 339 2223 Fax 0161 339 3226 Canada Multiquip 4110 Industriel Boul Laval Quebec Canada H7L 6V3 Contact jmartin multiquip com Tel 450 625 2244 Tel 877 963 4411 Fax 450 625 8664 COPYRIGHT 2013 MULTIQUIP INC Multiquip Inc the MQ logo are registered trademarks of Multiquip Inc and may not be used reproduced or altered without written permission All other trademarks are the property of their respective owners and used with permission This manual MUsT accompany the equipment at all times This manual is considered a permanent part of the equipment and should remain with the unit if resold The information and specifications included in this publication were in effect at the time of approval for printing Illustrations descriptions references and technical data contained in this manual are for guidance only and may not be considered as binding Multiquip Inc reserves the right to discontinue or change specifications design or the information published in this publication at any time without notice and without incurring any obligations