1. 5 Wavelength TCF 142 S 1310 nm TCF 142 M 850 nm TX Output TCF 142 S gt 5 dBm TCF 142 M gt 5 dBm RX Sensitivity TCF 142 S 25 dBm TCF 142 M 20 dBm Point to Point Transmission Half or Full duplex Multi drop Transmission Half duplex fiber ring Environmental Operating Temperature 0 to 60 C 32 to 142 F 5 to 95 RH Extended Operating Temperature for T models 40 to 75 C 40 to 167 F Storage Temperature 20 to 85 C 4 to 185 F 5 to 95 RH Power Input Power Voltage 12 to 48 VDC Power Line Protection 1 KV Burst EFT EN61000 4 4 1 KV Surge EN61000 4 5 Reverse Power Protection Protects against V V reversal Over Current Protection Protects against 2 signals shorted together 1 1A Power Consumption 100 mA at 12 VDC Mechanical Dimensions W x D x H 67 x 100 x 22 mm 90 x 100 x 22 mm including ears Material Aluminum 1 mm Gross Weight 140g Regulatory Approvals CE Class B FCC Part 15 sub Class B TUV EN 60950 UL UL 60950 EMI EN55022 1998 Class B EMS EN61000 4 2 ESD Criteria A Level 2 EN61000 4 3 RS Criteria A Level 2 EN61000 4 4 EFT Criteria A Level 2 EN61000 4 5 Surge Criteria A Level 3 EN61000 4 6 CS Criteria A Level 2 Free fall IEC 60068 2 32 WARNING 1 This unit is not meant to be sold to consumers It will only be shi
2. under any baudrate from 300 bps to 921 6 Kbps The TCF 142 simply converts the signal back and forth between serial RS 232 RS 422 or RS 485 and fiber and since the TCF 142 does not need to interpret the signal it does not need to know the baudrate of the transmitting device For this reason TCF 142 does not have any DIP switches or jumpers for setting the baudrate 2 Features e Ring or Point to Point transmission e Extend RS 232 422 485 transmission distance gt up to 40 km with single mode TCF 142 S gt up to 5 km with multi mode TCF 142 M Compact size Decrease signal interference Protect against electronic degradation and chemical corrosion Supports a baudrate up to 921 6 Kbps Extended operating temperature from 40 to 75 C for T models 3 Package Checklist Before installing the TCF 142 verify that the package contains the following items e TCF 142 S or TCF 142 M Fiber Converter e Quick Installation Guide e 7 contact terminal block connector e 3 contact terminal block connector Notify your sales representative if any of the above items is missing or damaged J 4 Dimensions and Appearance TCF 142 fiber converters are easy to set up and use The serial terminal block of one of the converters connects to your computer the serial terminal block of the other converter connects to your serial device and the two converters are connected by fiber cable s NOTE Electrostatic Discharge Warn
3. MOXN TCF 142 M T TCF 142 S T RS 232 422 485 to Fiber Converter Quick Installation Guide Eighth Edition July 2006 1 Overview Introduction The TCF 142 series Ver 3 1 or later converters are equipped with a multiple interface circuit that can handle RS 232 or RS 422 485 serial interfaces and multi mode or single mode fiber The TCF 142 converters extend serial transmission distance up to 5 km TCF 142 M with multi mode fiber or up to 40 km TCF 142 S with single mode fiber The TCF 142 must be configured to transmit a particular serial interface e g RS 232 and RS 485 signals cannot be transmitted at the same time Why convert serial to Fiber Fiber communication not only extends the communication distance but also provides many advantageous features IMMUNITY FROM ELECTRICAL INTERFERENCE Fiber is not affected by electromagnetic interference or radio frequency interference It provides a clean communication path and is immune to cross talk INSULATION Optical fiber is an insulator the glass fiber eliminates the need for using electric currents as the communication medium SECURITY Fiber cannot be tapped by conventional electric means and is very difficult to tap into optically Furthermore radio and satellite communication signals can be captured easily for decoding RELIABILITY amp MAINTENANCE Fiber is immune to adverse temperature and moisture conditions does not corrode or lose its signal and is not affected by short
4. be powered down and set to Ring mode Next make sure all cables are connected properly and then power up all devices connected to the ring After powering up the TCF 142 units if the Rx LEDs of the converters glow continuously power down and then power up ONE of the TCF 142 units in the ring to return the network to normal operation NOTE e g RS 485 multi drop communication Ring Mode can only be sued for half duplex applications The DIP switch array called DIP 2 is located inside the TCF 142 DIP 2 has two DIP switches used to adjust the pull high low resisters NOTE SW1 and SW2 should be set both to ON or both to OFF 4 Fiber Tx Green Blinking when fiber is transmitting data Fiber Rx Orange Blinking when fiber is receiving data 8 Specifications Model Name TCF 142 S TCF 142 S T TCF 142 M TCF 142 M T Serial Communication Signals for RS 232 TxD RxD SGND Signals for RS 422 TxD TxD RxD RxD SGND Signals for 4 wire RS 485 TxD TxD RxD RxD SGND Signals for 2 wire RS 485 Data Data SGND Baudrate 300 bps to 921 6 Kbps Surge protection 15 KV ESD Fiber Communication Connector type ST Distance TCF 142 S Single mode fiber for 40 km TCF 142 M Multi mode fiber for 5 km Support Cable TCF 142 S 8 3 125 8 7 125 9 125 or 10 125 um TCF 142 M 50 125 62 5 125 or 100 140 um
5. circuits power surges or static electricity Reverse Power Protection The Reverse Power Protection feature provides extra protection against accidentally connecting the power cables to the wrong terminal The converter is designed to detect automatically which power wire is positive and which is negative and then adjust the power supply accordingly Ring Mode To allow one half duplex serial device to communicate with multiple half duplex devices connected to a fiber ring you should configure the TCF 142 for ring mode by setting DIP switch SW4 to the On position The Tx port of a particular TCF 142 unit connects to the neighboring converter s Rx port to form the ring Note that when one node transmits a signal the signal travels around the ring until it returns back to the transmitting unit which then blocks the signal Users should ensure that the total fiber ring length is less than 100 km when using TCF 142 series converters P N 1802001420600 DIP Switch Selectable Terminator The termination resistor for many products of this type is set by a jumper located inside the product s casing To disable or change the resistor s strength the user must open the casing to reset the jumper MOXA offers a better solution since TCF 142 s termination resistor is set with a DIP Switch located on the outside of the converter s casing No Configuration Required for Baudrate Settings The TCF 142 works
6. erial Device TCF 142 TCF 142 Device Connecting RS 232 Serial Devices DTR DTR ee losk RTS RTS a ses lens Pc Rx Tx 4 p GND GND Fe _ Rx 4 a 7 BY Rx iT GND GND SAE EL Tx Rx Copper S210 Fiber See Copper Serial TCF 142 TCF 142 6 Switch Settings Device There are 4 DIP switches on the top end of the TCF 142 SW1 and SW2 are used to set the serial interface SW3 is used to enable or disable the 120 Q termination resistor SW4 is used to enable Ring mode or enable Point to Point mode a Serial Connection SW1 SW2 RS 232 ON OFF RS 422 OFF OFF RS 485 4 wire OFF OFF RS 485 2 wire OFF ON ATTENTION For Fiber Ring Users i le aie 6 CY RoHS A cH MADE IN TAWAN O O xs N he 150K Pull High Low Resister DIP 2 SW1 DIP 2 SW2 150K default OFF OFF 1K ON ON NOTE When termination is enabled we recommend using the 1K ON ON setting 7 LED Description There are 3 LEDs on the front panel of the TCF 142 LED Color Function Built in 1200 sw3 Terminator Enable ON Disable OFF Sw4 Ring mode ON Point to Point OFF mode PWR Red Steady ON Power is ON To avoid problems when setting up a fiber ring each TCF 142 unit making up the ring must
7. ing To protect the product from damage due to electrostatic discharge we recommend wearing a grounding device when maintaining TCF 142 22 0 mm 0 87 in l 6 mm 0 24 in 4mm sn 0 16 in E 19 fe S a b E a e a i g a T T 12 5mm 0 49 in 7mm 0 28 in 67 mm 2 64 in 78 mm 3 07 in ET Ec Rees Ee S5 NS 67 mm 2 64 in 90 2 mm 3 55 in 5 Wiring Examples Connecting the Power Supply Before using the TCF 142 you must first connect the DC power supply to the power supply terminal block located on the bottom side of the TCF 142 The TCF 142 uses a DC power supply Connecting RS 422 or 4 wire RS 485 Serial Devices omo ooo Rxt T 92 9 GND GND Rx _ T E Rx T R Tx Txt Rt XQ Re Tx R N Tx Rx a E Rx GND GND a at T Rx Serial Copper ese Fiber esos Copper Serial Device TCF 142 TCF 142 Device a Connecting 2 wire RS 485 Serial Devices ooo emo Data D a Data D Rx T GND GND 8 gr GND J GND Tx Rx J D Data a D Data Serial Copper S28 i 8528 Copper S
8. pped to manufacturers or factories 2 The DC source should come from an external adapter or 12 to 48 VDC source not from DC mains by using a transfer device 3 This unit should be installed or set up by a qualified service person Copyright 2006 Moxa Technologies Co Ltd All rights reserved Reproduction without permission is prohibited MOXN Tel 886 2 8919 1230 Fax 886 2 8919 1231 www moxa com support moxa com 6