Monte Carlo Fan Company 5RH52 User's Manual
Contents
1. check to be sure the screws securing the glassware are finger tight Check to be sure light bulb is tight in socket and not touching glass shade s If vibra tion persists from glass remove glass and install a 1 4 wide rubber band on glass neck to act as an insulator Replace glass and tighten screws against rubber band 5 Some fan motors are sensitive to signals from Solid State variable speed controls DO NOT USE a Solid State variable speed control 6 Allow break in period of 24 hours Most noises associated with a new fan will disappear after this period 1 Make sure that the ridge of the canopy engages the notch in the downrod ball See illustration in Step 6 of Downrod Mount installation 2 Check that all blades are screwed firmly into blade holders 3 Check that all blade holders are tightened securely to motor 4 Make sure that canopy and mounting bracket are tightened securely to ceiling junction box and junction box is mounted firmly to ceiling joist 5 Most fan wobble problems are caused when blade levels are unequal Check this level by selecting a point on the ceiling above the tip of one of the blades Measure this distance from blade tip to ceilng Keeping measure within 1 8 rotate the fan until the next blade is positioned for measure ment Repeat for each blade If all blade levels are not equal you can adjust blade levels by the fol lowing procedure To adjust a blade tip down insert a washer not supplied between t
2. Service panel and lock service dis connecting means to prevent power from being switched on accidentally When the service dis connecting means cannot be locked securely fasten a prominent warning device such as a tag to the service panel Loosen the 2 set screws till you can not feel them on inside of yoke TOOLS REQUIRED Wire Cutters Before installing this fan make sure the outlet box is properly installed to the house structure To reduce the risk of fire electric shock or personal injury mount to outlet box or supporting system acceptable for fan support Mounting must support at least 35 Ibs Place canopy on downrod as shown Pliers Step Ladder Use metal outlet box suitable for fan support must support 35 Ibs Before attaching fan to outlet box ensure the outlet box is securley fas tened by at least two points to a structural ceil ing member a loose box will cause the fan to wabble Use only the screws provided with the outlet box Thead leadwires and safety cable through downrod as shown Tighten the 2 set screws on the yoke once the downrod is in place Make sure the studs protruding from the bottom of the Mounting bracket are installed with threads all the way through the bracket Lift canopy and install knurled nuts as shown Tighten the knurled nuts securely The canopy should adjust for any irregu larity in the ceiling or Outlet box Align the hole in the Downrod with t
3. faults please check this Trouble Shooting Chart If a problem cannot be remedied or you are experiencing difficulty in installation please call our Customer Service Center at the number printed on your parts list insert sheet Warning Before servicing or cleaning unit Switch power off at Service panel and lock service disconnecting means to prevent power from being switched on accidentally When the service disconnecting means cannot 1 If fan does not start 2 If fan sounds noisy 3 If fan wobbles 4 If light does not work be locked securely fasten a prominent warning device such as a tag to the service panel 1 Check main and branch circuit fuses or circuit breakers 2 Check line wire connections to fan and switch wire connections in switch housing CAUTION Make sure main power is turned off 3 Make sure forward reverse switch is firmly in up or down position Fan will not operate when switch is in the middle 4 Make sure that shipping stabilizer tabs have been removed from motor 1 Check to make sure all screws in motor housing are snug not over tightened 2 Check to make sure the screws which attach the fan blade holder to the motor are tight 3 Check to make sure wire nut connectors in switch housing are not rattling against each other or against the interior wall of the switch housing CAUTION Make sure main power is turned off before entering switch housing 4 If using an optional Ceiling Fan Light Kit
4. OWNER S MANUAL Ceiling Fan Installation Instructions Total fan weight with light ee For 5RH52 Series Fans READ AND SAVE THESE INSTRUCTIONS MONTE CARLO Eo QUALITY CEILING FANS LISTED 10 11 12 is Installation SAFETY TIPS WARNING TO REDUCE THE RISK OF FIRE ELECTRIC SHOCK OR INJURY TO PERSONS OBSERVE THE FOLLOWING READ AND SAVE THESE INSTRUCTIONS Installation work and electrical wiring must be done by qualified person s in accordance with applicable codes ANSI NFPA 70 1999 including fire rated construction Use this unit only in the manner intended by the manufacturer If you have any questions contact the manufacturer After making the wire connections the wires should be spread apart with the grounded conductor and the equipment grounding con ductor on one side of the outlet box and ungrounded conductor on the other side of the outlet box Before you begin installing the fan Switch power off at Service panel and lock service disconnecting means to prevent power from being switched on accidentally When the service disconnecting means cannot be locked securely fasten a prominent warning device such as a tag to the service panel Be cautious read all instructions and safety information before installing your new fan Review the accompanying assembly diagrams When cutting or drilling into wall or ceiling do not damage electrical wiring and other hidden utilities Make sure the insta
5. ed conductor on the other side of the outlet box Attach blade arms using screws and washers in hardware pack Tighten screws securely Check the motor for shipping stabi lizers and remove if present Attach blades using screws and washers e Tighten screws secure y Connect plug from fan to switch house plug Un screw hex nut and rubber washer from light fixture Save for later Install 3 x 40 watt Candelabra bulbs Ea a np Install by twisting clockwise add 1 screw removed step 20 to light kit plate Tighten the 3 screws securely _ Loosen 2 screws and remove 1 screw from motor plate Save removed screw for use later s 1a Un screw the decorative finial nut kit plate and remove 1 screw Save from light fixture Save for later removed screw for use later Connect white wire from fan to white wire from light fixture Then plug blue wire from fan to black wire from light fixture ld d Install by twisting clockwise add 1 screw removed step 23 to light fix ture Tighten the 3 screws securely Attach glass to light fixture Install rubber washer and hex nut to glass to secure in place Install decorative finial nut to glass to secure in place TROUBLE SHOOTING If you have difficulty operating your new ceiling fan it may be the result of incorrect assembly installation or wiring In some cases these installation errors may be mistaken for defects If you experience any
6. he blade and blade holder at the screw closest to the motor To adjust a blade tip up insert washer not supplied between the blade and blade holder at the two screws farthest from the motor Reverse the posi tion of the washer if blades mount from top of blade 6 If blade wobble is still noticeable interchanging two adjacent side by side blades can redistrib ute the weight and possibly result in smoother operation 1 Check blue wire from fan to make sure it is connected to hot wire from house 2 Check for loose or disconnected wires in fan switch housing 3 Check for loose or disconnected wires in light kit 4 Check for faulty light bulbs CAUTION Make sure main power is turned off before entering switch housing MONTE CARLO Customer Service Center 740 S W Loop 820 Suite 110 Fort Worth Texas 76115 1 800 519 4092
7. he hole in the Yoke Insert the Pin through the Yoke and Downrod until the point appears on the other side Hang assembled fan from the mounting bracket installed to ceiling in previous step Make sure the fan is hanging straight Rotate fan until the tab on the Mounting bracket engages the slot on the Downrod Ball This must be done to prevent the fan body from rotating when the blades are in motion Connect black and blue wire from fan to Black or Hot wire from house Connect White wire from Fan to White Neutral wire from house Connect Ground leads from mounting bracket and downrod to Ground lead from house Refer to Safety Tips section of manual Place decorative blade medallion on blade opposite blade arm Make sure the up side of blade arm is installed upper 3 lag lock screw washer Fan and light kit combinations over 35 Ibs in both flush and downrod mode the safety cable must be installed into the house struc ture beams using the 3 lag screws washers and lock washers provided Make sure that when the a cable is fully extended the lead wires are longer than the cable and no stress is placed on the lead wires Make wire connections to power source using wire nuts provided Make sure that no filiments are outside of the wirenut After making the wire connections the wires should be spread apart with the grounded con ductor and the equipment grounding conductor on one side of the outlet box and unground
8. llation site you choose allows the fan blades to rotate without any obstructions Allow a minimum clearance of 7 feet from the floor to the trailing edge of the blade To reduce the risk of fire electric shock or personal injury mount to outlet box or supporting system acceptable for fan support Mounting must support at least 35 Ibs Do not bend blade holders during installation to motor balancing or during cleaning Do not insert foreign object between rotating blades Attach the mounting bracket using only the hardware supplied with the outlet box To reduce the risk of fire or electric shock do not use this fan with any solid state fan speed control device or variable speed control The combustion airflow needed for safe operation of fuel burning equipment may be affected by this unit s operation Follow the heat ing equipment manufacturer s guideline safety standards such as those published by the National Fire Protection Association NFPA and the American Society for Heating Refrigeration and Air Conditioning Engineers ASHRAE and the local code authorities Before servicing or cleaning unit Switch power off at Service panel and lock service disconnecting means to prevent power from being switched on accidentally When the service disconnecting means cannot be locked securely fasten a prominent warning device such as a tag to the service panel Phillips Screwdriver Before you begin installing the fan Switch power off at