Home
Monte Carlo Fan Company 5OBR52 User's Manual
Contents
1. Make wire connections to power source using wire nuts provided Make sure that no filiments are outside of the wirenut After making the wire connections the wires should be spread apart with the grounded conductor and the equipment grounding conductor on one side of the outlet box and ungrounded conductor on the other side of the outlet box Align hole in downrod with hole in yoke and install cross pin Remote Receiver Dip switches Set dip switches on the Remote Transmitter and Remote Receiver to the same settings This must be done so the units will communcate properly If you have other fans you can set to control from one transmitter by setting both receivers the same as the transmitter If you have more than one fan with remote You can set the dip switches to different positiosns to have seperate control Mh oe reel remote receiver by sliding into opening in the Mounting bracket Make sure that the dip Switches on the Transmitter and the Receiver are set to the same position See Fig 37 for remote operation Lift Canopy to ceiling aligning the key hole slots with the screws on the bottom of the Mounting bracket Rotate the canopy Counter Clockwise to lock in place Tighten the screws to secure the Canopy See inset for Keyhole shape Raise fan with downto assembled to the ceiling bracket and hang fan assembly Be sure to rotate the downrod ball so that the notch in the bracket engages the slot in the ball Make wiri
2. is turned off before entering switch housing 4 Some fan motors are sensitive to signals from Solid State variable speed controls DO NOT USE a Solid State variable speed control 5 Allow break in period of 24 hours Most noises associated with a new fan will disappear after this period 1 Make sure that the ridge of the canopy engages the notch in the downrod ball 2 Check that all blades are screwed firmly into blade holders 3 Check that all blade holders are tightened securely to motor 4 Make sure that canopy and mounting bracket are tightened securely to ceiling junction box and junction box is mounted firmly to ceiling joist 5 Most fan wobble problems are caused when blade levels are unequal Check this level by selecting a point on the ceiling above the tip of one of the blades Measure this distance from blade tip to ceilng Keeping measure within 1 8 rotate the fan until the next blade is posi tioned for measurement Repeat for each blade If all blade levels are not equal you can adjust blade levels by the following procedure To adjust a blade tip down insert a washer not supplied between the blade and blade holder at the screw closest to the motor To adjust a blade tip up insert washer not supplied between the blade and blade holder at the two screws farthest from the motor Reverse the position of the washer if blades mount from top of blade 6 1f blade wobble is still noticeable interchanging two adjacent side by si
3. Owner s Manual Ceiling Fan Installation Instructions Total fan weigh with light o For 5OBR52 Series Fans READ AND SAVE THESE INSTRUCTIONS MONTE CARLO Dus Quality Ceiling fans LISTED Installation SAFETY TIPS WARNING TO REDUCE THE RISK OF FIRE ELECTRIC SHOCK OR INJURY TO PERSONS OBSERVE THE FOLLOWING READ AND SAVE THESE INSTRUCTIONS Installation work and electrical wiring must be done by qualified person s in accordance with applicable codes and standards ANSI NFPA 70 1996 including fire rated construction Use this unit only in the manner intended by the manufacurer If you have any questions contact the manufacturer After making the wire connections the wires should be spread apart with the grounded conductor and the equipment grounding conductor on one side of the outlet box and ungrounded conductor on the other side of the outlet box Before you begin installing the fan Switch power off at Service panel and lock service disconnecting means to prevent power from being switched on accidentally When the service disconnecting means cannot be locked securely fasten a prominent warning device such as a tag to the service panel Be cautious read all instructions and safety information before installing your new fan Review the accompanying assembly diagrams When cutting or drilling into wall or ceiling do not damage electrical wiring and other hidden utilities Make sure the installation site y
4. de blades can redistribute the weight and possibly result in smoother operation 1 Check wire from fan to make Sure it is connected to hot wire from house 2 Check for loose or disconnected wires in fan switch housing 3 Check for loose or disconnected wires in light kit 4 Check for faulty light bulbs CAUTION Make sure main power is turned off before entering switch housing WARNING Before attempting to replace the fuse make sure the main power is turned off to the fan Replace only with 3 amp fuse Fuse is on top of motor hous ing MONTE CARLO Customer Service Center 2900 W Seminary Dr Suite 200 Fort Worth Texas 76133 1 800 519 4092 9 21 04 REV 0O New made from 5AHR manual
5. loating brackets onto blades aligning holes in blade with the float ing bracket Loosen 2 screws and remove 1 screw to allow bottom fan plate to be installed If attaching light kit skip to step 28 Attach center cover plate by screw ing into center of fan Plug white wire from fan to white wire from light kit Then plug black wire from fan to black wire from light kit __ Place light kit over screws and twist J O light kit with key hole slots into Install the 100 watt halogen bulb Attach glass by locating dimples in Do not touch bulb surface as oily light kit with the groves in glass and residue from skin can cause the bulb twisting clockwise till tight place Replace screw removed and then tighten all 3 screws securely Attach cover of remote by placing Install wall control unit to outlet box EET PAE EA over buttons and snaping into place using machine screws provided into wall remote Duracell MN21 Eveready A23 GP 23A all 12V Fan speed Light dim control but mer for up tons and down lights Fan reverse button Fan on off To control fan speed select from High Medium press and hold D L button To turn off either up or down light press and quickly release either U L or D L button Press button marked Be to reverse the rotation direction of the fan ades with screws provided Trouble Shooting If you have difficulty operating your new ceiling fan i
6. ng connections as indicated above White from fan to white from remote marked N Orange from fan to Orange from remote marked Light up Blue from fan to blue from remote marked down light Black from fan to Red from remote marked L White from house to white from remote marked AC N Black from house to Black from remote marked AC L Connect all green ground wires to Ground wire from House Loosen 2 screws with key slots and remove the 1 screw without ket slot Save screw removed Take plate with glass and place over the 2 screws and twist to hold in place Replace screw removed Tighter all 3 screws securely Check the motor for plastic shipping sta bilizer tabs and remove if they are pres Attach blade arms to blades using ent The screws washers and motor pads the blade arm screws and washers are pre installed to the blade holders provided Attach blade assembly to motor and tighten screws securely Install lower cover plate over loos ened screws and twist lower cover plate with key hole slots into place Remove the 3 screws holding plates if not using light kit push wires up together if not using light kit to and tighen all 6 screws securely seperate lower cover plate from light plate n Et Loosen 2 screws with slots remove Loosen 2 screws and remove 1 screw one screw and place plate over holes and twist into place Replace the screw removed and tighten all screws securely on light kit cover Place f
7. ou choose allows the fan blades to rotate without any obstructions Allow a minimum clearance of 7 feet from the floor to the trailing edge of the blade To reduce the risk of fire electric shock or personal injury mount to outlet box or supporting system acceptable for fan support Mounting must support at least 35 Ibs 16kg Do not bend blade holders during installation to motor balancing or during cleaning Do not insert foreign object between rotating blades Attach the mounting bracket using only the hardware supplied with the outlet box To reduce the risk of fire or electric shock do not use this fan with any solid state fan speed control device or variable speed control If this unit is to be installed over a tub or shower it must be marked as appropriate for the application NEVER place a switch where it can be reached from a tub or shower The combustion airflow needed for safe operation of fuel burning equipment may be affected by this unit s operation Follow the heating equip ment manufacturer s guideline safety standards such as those published by the National Fire Protection Association NFPA and the American Society for Heating Refrigeration and Air Conditioning Engineers ASHRAE and the local code authorities Before servicing or cleaning unit Switch power off at Service panel and lock service disconnecting means to prevent power from being switched on accidentally When the service disconnecting means cannot be locked
8. securely fasten a prominent warning device such as a tag to the service panel Phillips Screwdriver Before you begin installing the fan Switch power off at Service panel and lock service dis connecting means to prevent power from being switched on accidentally When the service dis connecting means cannot be locked securely fasten a prominent warning device such as a tag to the service panel Install 4 x 25 watt candelabra base bulbs included Wire Cutters TOOLS REQUIRED Pliers Before installing this fan make sure the outlet box is properly installed to the house structure To reduce the risk of fire electric shock or per sonal injury mount to outlet box or supporting system acceptable for fan support Mounting must support at least 35 Ibs 16 kg Install downrod to canopy and then install yoke cover to downrod Thread wires and safety cable through downrod Step Ladder Install the Mountiing Bracket to the Outlet box Use only the screws provided with the outlet box Loosen 2 set screws and remove pin with keeper for downrod Tighten 2 downrod set screws and lock nuts Canadian mounting only For Canadian installation in both flush and downrod mode the safety cable must be installed into the house structure beams using the 3 lag screws provided Make sure that when the safety cable is fully extended the leadwires are longer than the cable and no stress is placed on the leadwires
9. t may be the result of incorrect assembly installation or wiring In some cases these installation errors may be mistaken for defects If you experience any faults please check this Trouble Shooting Chart If a problem cannot be remedied or you are experiencing difficulty in installation please call our Customer Service Center at the number printed on your parts list insert sheet Warning Before servicing or cleaning unit Switch power off at Service panel and lock service dis connecting means to prevent power from being switched on accidentally When the service dis connecting means cannot be locked securely fasten a prominent warning device such as a tag 1 If fan does not start 2 If fan sounds noisy 3 If fan wobbles 4 If light does not work peN PU 2 to the service panel 1 Check main and branch circuit fuses or circuit breakers 2 Check line wire connections to fan and switch wire connections in switch housing 3 Check to make sure the dip switches from the transmitter and receiver are set on the same frequency CAUTION Make sure main power is turned off 1 Check to make sure all screws in motor housing are snug not over tightened 2 Check to make sure the screws which attach the fan blade holder to the motor are tight 3 Check to make sure wire nut connectors in switch housing are not rattling against each other or against the interior wall of the switch housing CAUTION Make sure main power