Home

Monte Carlo Fan Company 5CE52 User's Manual

image

Contents

1. down ball and remove pin Remove the ball Insert cotter pin in to cross pin to secure Thread wires through half ball put ball back over downrod and replace pin then tighten the two set screws Safety cable installation For Canadian installation and for USA fan and light kit combinations over 35 Ibs in both flush and downrod mode the safety cable must be installed into the house structure beams using the 3 lag screws provided Make sure that when the safety cable is fully extended the leadwires are longer than the cable and no stress is placed on the leadwires 2 Make wire connections to power source using wire nuts provided Make sure that no filiments are outside of the wirenut After making the wire connections the wires should be spread apart with the grounded conductor and the eguipment grounding conductor on one side of the outlet box and ungrounded conductor on the other side of the outlet box 2 Lift Canopy to ceiling aligning the key hole slots with the screws on the bottom of the Mounting bracket Rotate the canopy Counter Clockwise to lock in place Tighten the screws to secure the Canopy See inset for Keyhole shape House Fan Black mm Black LE zeue White EB __ White Green XXXF ae ie Green downrod XXXXXI Green Bracket For pullchain controls follow diagram above Make sure that all exposed wiring is secured inside wire nuts Note Wires from house may var
2. Total fan weight Owner s MERE For 5CE52 Series Fans READ AND SAVE THESE INSTRUCTIONS Quality Ceiling fans MONTE CARLO un Cc 2 O J un cC 2 ay To J un Cc o LL O Oo O NOU Installation SAFETY TIPS WARNING TO REDUCE THE RISK OF FIRE ELECTRIC SHOCK OR INJURY TO PERSONS OBSERVE THE FOLLOWING READ AND SAVE THESE INSTRUCTIONS Installation work and electrical wiring must be done by qualified person s in accordance with applicable codes and standards ANSI NFPA 70 1999 including fire rated construction Use this unit only in the manner intended by the manufacturer If you have any questions contact the manufacturer After making the wire connections the wires should be spread apart with the grounded conductor and the equipment grounding conductor on one side of the outlet box and ungrounded conductor on the other side of the outlet box Before you begin installing the fan Switch power off at Service panel and lock service disconnecting means to prevent power from being switched on accidentally When the service disconnecting means cannot be locked securely fasten a prominent warning device such as a tag to the service panel Be cautious read all instructions and safety information before installing your new fan Review the accompanying assembly diagrams When cutting or drilling into wall or ceiling do not damage electrical wiring and other hidden utilities Make s
3. and Air Conditioning Engineers ASHRAE and the local code authorities Before servicing or cleaning unit Switch power off at Service panel and lock service disconnecting means to prevent power from being switched on accidentally When the service disconnecting means cannot be locked securely fasten a prominent warning device such as a tag to the service panel Phillips Screwdriver Before you begin installing the fan Switch power off at Service panel and lock service disconnecting means to prevent power from being switched on accidentally When the service disconnecting means cannot be locked securely fasten a prominent warning device such as a tag to the service panel Remove the 4 screws attaching the Mounting neck the mounting plate Retain the 4 screws for re assembly TOOLS REOUIRED Wire Cutters Pliers OUTLET BOX METHOD injury The fan in this box may be either directly sup ported from a structural framing member of a build ing and or may be mounted to an outlet box marked acceptable for fan support of of 31 8 kg 70lbs or less Most outlet boxes commonly used for the sup port of lumminaires may not be acceptable for fan support and may need to be replaced Consult a qualified electrician if in doubt BUILDING STRUCTURE METHOD Screws Secure mounting plate directly to a joist from the buliding structure via the two knock out holes on the outlet box Use only the appropri ate wood scre
4. el by selecting a point on the ceiling above the tip of one of the blades Measure this distance from blade tip to ceilng Keeping measure within 1 8 rotate the fan until the next blade is positioned for measurement Repeat for each blade If all blade levels are not egual you can adjust blade levels by the following procedure To adjust a blade tip down insert a washer not supplied between the blade and blade holder at the screw closest to the motor To adjust a blade tip up insert washer not supplied between the blade and blade holder at the two screws farthest from the motor Reverse the position of the washer if blades mount from top of blade 6 If blade wobble is still noticeable interchanging two adjacent side by side blades can redistribute the weight and possibly result in smoother operation 1 Check wire from fan to make sure it is connected to hot wire from house 2 Check for loose or disconnected wires in fan switch housing 3 Check for loose or disconnected wires in light kit 4 Check for faulty light bulbs CAUTION Make sure main power is turned off before entering switch housing MONTE CARLO Customer Service Center 740 S W Loop 820 Suite 110 Fort Worth Texas 76115 1 800 519 4092
5. nnot be locked securely fasten a prominent warning device such as a tag 1 If fan does not start 2 If fan sounds noisy 3 If fan wobbles 4 If light does not work to the service panel 1 Check main and branch circuit fuses or circuit breakers 2 Check line wire connections to fan and switch wire connections in switch housing CAUTION Make sure main power is turned off 1 Check to make sure all screws in motor housing are snug not over tightened 2 Check to make sure the screws which attach the fan blade holder to the motor are tight 3 Check to make sure wire nut connectors in switch housing are not rattling against each other or against the interior wall of the switch housing CAUTION Make sure main power is turned off before entering switch housing 4 Some fan motors are sensitive to signals from Solid State variable speed controls DO NOT USE a Solid State variable speed control 5 Allow break in period of 24 hours Most noises associated with a new fan will disappear after this period 1 Make sure that the ridge of the canopy engages the notch in the downrod ball 2 Check that all blades are screwed firmly into blade holders 3 Check that all blade holders are tightened securely to motor 4 Make sure that canopy and mounting bracket are tightened securely to ceiling junction box and junction box is mounted firmly to ceiling joist 5 Most fan wobble problems are caused when blade levels are unegual Check this lev
6. ure the installation site you choose allows the fan blades to rotate without any obstructions Allow a minimum clearance of 7 feet from the floor to the trailing edge of the blade WARNING Risk of fire electric shock or personal injury The fan in this box may be either directly supported from a structural framing mem ber of a building and or may be mounted to an outlet box marked acceptable for fan support of 31 8 kg 70 Ibs or less Most outlet boxes commonly used for the support of luminaires may not be acceptable for fan support and may need to be replaced Consult a qualified electrician if in doubt Do not bend blade holders during installation to motor balancing or during cleaning Do not insert foreign object between rotating blades Attach the mounting bracket using only the hardware supplied with the outlet box To reduce the risk of fire or electric shock do not use this fan with any solid state fan speed control device or variable speed control If this unit is to be installed over a tub or shower it must be marked as appropriate for the application NEVER place a switch where it can be reached from a tub or shower The combustion airflow needed for safe operation of fuel burning equipment may be affected by this unit s operation Follow the heating equip ment manufacturer s guideline safety standards such as those published by the National Fire Protection Association NFPA and the American Society for Heating Refrigeration
7. ws and washers included with your fan Caution Wood screws must go through into the building joist Step Ladder Remove Safety bar from mounting bracket by loosing screws sliding bar to side and lifting it off the 2 screws Install the mounting Plate to approved fan brace and box combination use only the hard ware provided with the fan brace and box A Lift mounting neck to mounting Plate and align screws Thread leadwire and safety cable through downrod and half ball _ yd Tighten yoke set screws securely and evenly Hang assembled fan from the mounting bracket installed to ceiling in previous step Make sure the fan is hanging straight Rotate fan until the tab on the Mounting bracket engages the slot on the Downrod Ball This must be done to prevent the fan body from rotating when the blades are in motion Secure mounting neck to the mounting plate with four screws to become a complete mount ing bracket Loosen the 2 set screws in the yoke Insert downrod into yoke aligning large hole in the downrod with the large hole in the yoke Insert cross pin though yoke and downrod Thread wires and safety cable through upper body and install over downrod to fan body Next thread wires and safety cable through canopy and place over downrod Re install safety bar removed in step 3 by placing safety bar on screws sliding into place and tightening the 2 screws Loosen two set screws holding half ball slide
8. y in color and may not include ground wire After wiring is complete gently push wires into junction box with wire nuts pointing upward Refer to point 3 of safety tips Place blade arms onto the other side of the blade and aligning holes Insert screws with fabric washers through the holes and tighten securely After attaching blades install the switch hous ing with the three screws previously removed Light Switch jam Fan Switch wall _ Control For control of fan and optional light from wall location follow diagram above NOTE A profes sional electrician is recommended for this type of installation Check the motor for plastic shipping stabilizer tabs and remove them if they are present Attach blade assembly to motor by tighten screws securely Trouble Shooting If you have difficulty operating your new ceiling fan it may be the result of incorrect assembly installation or wiring In some cases these installation errors may be mistaken for defects If you experience any faults please check this Trouble Shooting Chart If a problem cannot be remedied or you are experiencing difficulty in installation please call our Customer Service Center at the number printed on your parts list insert sheet Warning Before servicing or cleaning unit Switch power off at Service panel and lock service dis connecting means to prevent power from being switched on accidentally When the service dis connecting means ca

Download Pdf Manuals

image

Related Search

Related Contents

Texte intégral PDF (2 Mo)  Sensilevel a galleggiante serie 4400 per montaggio  Operation and adjustment instructions  InLine 55649L dust cover  発光式微量酸素分析計  

Copyright © All rights reserved.
Failed to retrieve file