Home

Monte Carlo Fan Company 5ALR56 User's Manual

image

Contents

1. Refrigeration and Air Conditioning Engineers ASHRAE and the local code authorities Before servicing or cleaning unit Switch power off at Service panel and lock service disconnecting means to prevent power from being switched on accidentally When the service disconnecting means cannot be locked securely fasten a prominent warning device such as a tag to the service panel TOOLS REQUIRED PhillipsScrewdriver Wire Cutters Ladder PliersStep Warning Risk of fire electric shock or personal T Before you begin installing the fan Switch power off at Service panel and lock service dis connecting means to prevent power from being switched on accidentally When the service dis connecting means cannot be locked securely fasten a prominent warning device such asa tag to the service panel ng the Mounting Remove the 4 screws attachi neck the mounting plate Retain the 4 screws for re assembly injury The fan in this box may be either directly sup ported from a structural framing member of a build ing and or may be mounted to an outlet box marked acceptable for fan support of of 31 8 kg 7Olbs or less Most outlet boxes commonly used for the sup port of lumminaires may not be acceptable for fan Support and may need to be replaced Consult a qualified electrician if in doubt BUILDING STRUCTURE METHOD Mounting Pa Plate N P Wood Screws i Outlet box l Secure mounting plate directly to a joist from the b
2. Owner s Mehri Ceiling Fan Installation Instructions Total fan weight with light kit included o For 5ALR56 Series Fans READ AND SAVE THESE INSTRUCTIONS MONTE CARLO Mu Quality Ceiling fans LISTED oe 10 To reduce the risk of fire or electric shock do not use this fan with any solid state fan speed control device or variable speed control 12 13 14 15 Installation SAFETY TIPS WARNING TO REDUCE THE RISK OF FIRE ELECTRIC SHOCK OR INJURY TO PERSONS OBSERVE THE FOLLOWING READ AND SAVE THESE INSTRUCTIONS Installation work and electrical wiring must be done by qualified person s in accordance with applicable codes and standards ANSI NFPA 70 1999 including fire rated construction Use this unit only in the manner intended by the manufacurer If you have any questions contact the manufacturer After making the wire connections the wires should be spread apart with the grounded conductor and the equipment grounding con ductor on one side of the outlet box and ungrounded conductor on the other side of the outlet box Before you begin installing the fan Switch power off at Service panel and lock service disconnecting means to prevent power from being switched on accidentally When the service disconnecting means cannot be locked securely fasten a prominent warning device such as a tag to the service panel Be cautious read all instructions and safety information before installing your new fan R
3. ce Center 740 S W Loop 820 Suite 110 Fort Worth Texas 76115 1 800 519 4092
4. e mistaken for defects If you experience any faults please check this Trouble Shooting Chart If a problem cannot be remedied or you are experiencing difficulty in installation please call our Customer Service Center at the number printed on your parts list insert sheet Warning Before servicing or cleaning unit Switch power off at Service panel and lock service dis connecting means to prevent power from being switched on accidentally When the service dis connecting means cannot be locked securely fasten a prominent warning device such as a tag to the service panel 1 If fan does not start 1 Check main and branch circuit fuses or circuit breakers 2 If fan sounds noisy 3 If fan wobbles 4 If light does not work 2 Check line wire connections to fan and switch wire connections in switch housing 3 Check to make sure the dip switches from the transmitter and receiver are set on the same frequency CAUTION Make sure main power is turned off 1 Check to make sure all screws in motor housing are snug not over tightened 2 Check to make sure the screws which attach the fan blade holder to the motor are tight CAUTION Make sure main power is turned off before entering switch housing 3 Allow break in period of 24 hours Most noises associated with a new fan will disappear after this period 1 Make sure that the ridge of the canopy engages the notch in the downrod ball 2 Check that all blades are screwed firmly i
5. et engages the slot on the Downrod Ball This must be done to prevent the fan body from rotating when the blades are in motion rem the Mounting bracket Make sure that the dip switches on the Transmitter and the Receiver are set to the same position See Fig 31 for remote operation F Make wire connections to power source using wire nuts provided Make sure that no filiments are outside of the wirenut After making the wire connections the wires should be spread apart with the grounded conductor and the equipment grounding conductor on one side of the outlet box and ungrounded conductor on the other side of the outlet box Lift Glass and lower cage to the fan body Align the 4 screws on the cage with 4 key hole slots in fan body See Inset for keyhole shape Rotate the glass and cage counter clockwise to lock into place ounting only he Pa m Bi Sh e e a n a Safety Cable wae For Canadian installation in both flush and downrod mode the safety cable must be installed into the house structure beams using the 3 lag screws pro vided Make sure that when the safety cable is fully extended the leadwires are longer than the cable and no stress is placed on the leadwires Make wiring connections as indicated above White from fan to white from remote marked N Orange from fan to Orange from remote marked Light up Blue from fan to blue from remote marked down light Black from fan to Red from remote marked L White
6. eview the accompanying assembly diagrams When cutting or drilling into wall or ceiling do not damage electrical wiring and other hidden utilities Make sure the installation site you choose allows the fan blades to rotate without any obstructions Allow a minimum clearance of 7 feet from the floor to the trailing edge of the blade WARNING Risk of fire electric shock or personal injury The fan in this box may be either directly supported from a structural fram ing member of a building and or may be mounted to an outlet box marked acceptable for fan support of 31 8 kg 70 Ibs or less Most outlet boxes commonly used for the support of luminaires may not be acceptable for fan support and may need to be replaced Consult a qualified electrician if in doubt Do not bend blade holders during installation to motor balancing or during cleaning Do not insert foreign object between rotating blades Attach the mounting bracket using only the hardware supplied with the outlet box If this unit is to be installed over a tub or shower it must be marked as appropriate for the application NEVER place a switch where it can be reached from a tub or shower The combustion airflow needed for safe operation of fuel burning equipment may be affected by this unit s operation Follow the heat ing equipment manufacturer s guideline safety standards such as those published by the National Fire Protection Association NFPA and the American Society for Heating
7. from house to white from remote marked ACN Black from house to Black from remote marked AC L Connect all green ground wires to Ground wire from House Lift Canopy to ceiling aligning the key hole slots with the screws on the bottom of the Mounting bracket Rotate the canopy Counter Clockwise to lock in place Tighten the screws to secure the Canopy See inset for Keyhole shape Tighten the 4 screws to Secure the glass into place Install wall control unit to outlet box using machine screws provided Attach cover of remote by placing Remove cover by snaping off from over buttons and snaping into place top or bottom Install 12V battery into wall remote Duracell MN21 Eveready A23 GP 23A all 12V Fan speed control but Light dimmer tons for up and down lights Fan on off ee To control fan speed select from High Medium or low speed buttons To turn the fan off press the Fan on off button To dim upper lights Attach front cover to wall control press and hold U L botton To dim Lower lights with screws provided press and hold D L button To turn off either up or down light press and quickly release either U L or D L button Press button marked REV to reverse the rotation direction of the fan blades Trouble Shooting If you have difficulty operating your new ceiling fan it may be the result of incorrect assembly installation or wiring In some cases these installation errors may b
8. he other side Install the Keeper Pin Install tines of upper cage by inserting into the 4 slots on the hub Tighten using Phillips screwdriver Repeat 3 more times until all 4 tines are in place Tighten the 2 Set screws on the Yoke once the downrod is in place Install Canopy Cover Cage Assembly and Yoke cover onto the Downrod Next thread the fan leadwire from top of fan through the downrod r bs Slide the Yoke Cover and cage down on the fan body The Cage should engage 4 slots in the upper glass Tighten the Set Screw in on the top of the Cage This will prevent any rattling aoe are now ready to hang the fan Remote Receiver Dip switches Set dip switches on the Remote Transmitter and Remote Receiver to the same settings This must be done so the units will communcate properly If you have other fans you can set to control from one transmitter by setting both receivers the same as the transmitter If you have more than one fan with remote You can set the dip switches to different positiosns to have seperate control Re install safety bar removed in step 3 by placing safety bar on screws Sliding into place and tightening the 2 screws Loosen screws in on the glass cage this will allow the screws to fit into the Keyhole slots on the fan housing Your fan should look like this You installed to ceiling in previous step Make sure the fan is hanging straight Rotate fan until the tab on the Mounting brack
9. nto blade holders 3 Check that all blade holders are tightened securely to motor 4 Make sure that canopy and mounting bracket are tightened securely to ceiling junction box and junction box is mounted firmly to ceiling joist 5 Most fan wobble problems are caused when blade levels are unequal Check this level by selecting a point on the ceiling above the tip of one of the blades Measure the distance from blade to ceiling Keeping measure within 1 8 rotate the fan until the next blade is posi tioned for measurement Repeat for each blade If all blade levels are not equal you can adjust blade levels by the following procedure To adjust a blade tip down insert a washer not supplied between the blade and blade holder at the screw closest to the motor To adjust a blade tip up insert washer not supplied between the blade and blade holder at the two screws farthest from the motor Reverse the position of the washer if blades mount from top of blade 6 If blade wobble is still noticeable interchanging two adjacent side by side blades can redistribute the weight and possibly result in smoother operation 1 Check blue wire from fan to make sure it is connected to hot wire from house 2 Check for loose or disconnected wires in fan switch housing 3 Check for loose or disconnected wires in light kit 4 Check for faulty light bulbs CAUTION Make sure main power is turned off before entering switch housing MONITE CARLO Customer Servi
10. uliding structure via the two knock out holes on the outlet box Use only the appropri ate wood screws and washers included with your fan Caution Wood screws must go through into the building joist Remove Safety bar from mounting bracket by loosing screws sliding bar to side and lifting it off the 2 screws Install the mounting Plate to approved fan brace and box combination use only the hard ware provided with the fan brace and box Place Floating decorative holder onto blade The tabs should align with the holes in the blade Secure mounting neck to the mounting plate with four screws to become a complete mount ing bracket Lift mounting neck to mounting Plate and align screws 7 i maa i k 7 om roe F a a i 7 if oe a i it m Aa r j 4 d ae gt AF Da l 7 i h g we q B A a F 3 7 At EF 1 Cree M gt a te N iy 3 i Install 3 each Max 25 Watt cande labra base bulbs into the sockets on top of the fan as shown Install Blade blade holder assembly to fan motor using large motor screws Repeat this process 4 more times until all blades are installed to the fan Place the Main holder over the blade and install 3 screws and tighten securely Repeat this process again for each blade Insert downrod into yoke on top of the Fan Body Align the hole in the Downrod with the hole in the Yoke Insert the Pin through the Yoke and Downrod until the point appears on t