Home
MINOLTA W121CA TSC2 Use and Maintenance Manual
Contents
1. XX 2 A WARNING E installation Always install the expansion panel s Do not place the power cord near a heater e No installation may cause fire and electric e It may cause fire and electric shock shock accident Do not use the power cord near flammable Do not disassemble or modify products gas or combustibles such as gasoline benzene thinner etc e It may cause explosion or fire It may cause failure and electric shock E Operation Plug in the power plug properly e Otherwise it will cause electric shock or fire due to heat generation or electric shock Do not modify power cord length e It will cause electric shock or fire due to heat generation Do not operate or stop the unit by inserting or pulling out the power plug e It will cause electric shock or fire due to heat generation FV Do not share the outlet with other appliances e It will cause electric shock or fire due to heat generation Do not damage or use an unspecified power cord e It will cause electric shock or fire sek YS Le ea KA AB Always plug into a grounded outlet e No grounding may cause electric shock See Installation Manual Unplug the unit if strange sounds odors or smoke come from it e Otherwise it may cause fire and electric shock accident Do not use the socket if it is loose or damaged e It may cause fire and electric
2. Window Type OWNER S MANUAL WINDOW TYPE ROOM AIR CONDITIONER 8 e Please read carefully and thoroughly this manual gt before operating this unit 5 Room Air Conditioner 1 Contact the authorized SVC man for repair or maintenance of this unit Contact the installer for installation of this unit e The appliance is not intended for use by young children or infirm persons without supervision e Young children should be supervised to ensure that they do not play with the appliance MODELS W091CA Tsco e MODELOS W092CA TsGo NOM hue D W121CA Tsc2 W122CA Tsco W182CA TSN2 W182CMH TSN1 W081CM Tsc2 W182CA TSN0 W182CM Tsno W242CM Tsno W242CA TSN0 W182CM TSN2 Antes de usar su aire acondionado lea este manual cuidadosamente y mant ngalo para futura referencia Aire Acondicionado Tipo de Ventana MANUAL DEL USUARIO Window Type Air Conditioner Owner s Manual TABLE OF CONTENTS J FOR YOUR RECORDS Write the model and serial numbers here Model Serial You can find them on a label on the side of each unit Dealer s Name recautions Date Purchased E Staple your receipt to this page in the event you need Instructions it to prove date of purchase or for warranty issues pP READ THIS MANUAL Inside you will find many helpful hints on how to use and maintain your air conditioner properly Just a little preventive care on your part can save you a great deal of time and money
3. AUTO RESTART In failure of electric power the unit runs as previous setting operation How to Insert the B 1 Remove the cover from the back of Do not use rechargeable batteries such batteries differ from the remote controller standard dry cells in shape dimensions and performance 2 Insert the two batteries e Remove the batteries from the remote controller if the air conditioner is not going to be used for an extended length of time 3 Re attach the cover Operating l Instructions Adjusting the Air Flow Direction Additional controls and important information Ventilation The ventilation lever must be in the CLOSE position in order to maintain the best cooling conditions When fresh air is necessary in the room set the ventilation lever to the OPEN position The damper is opened and room air is drawn out al CLOSE ma VENT sis OPEN Before using the ventilation feature position the lever as shown First pull down part to horizontal line with part Air Direction The direction of air can be controlled whenever you want to cool by adjusting the horizontal louver and the vertical VIE aa e HORIZONTAL AIR DIRECTION CONTROL To control horizontal direction of air flow press the air flow direction control button and the air flow will be swept horizontally by the automatic air swing system If you want to stop the air flow from moving press the button aga
4. drain pipe then connect a drain hose a to the pipe elbow as shown in Fig 2 DRAIN PIPE DRAIN ELBOW DRAIN HOSE Operating Instructions Adjusting the Air Flow Direction TURN THE AIR CONDITIONER OFF AND REMOVE THE PLUG FROM THE POWER OUTLET Outdoor Coils d The coils on the outdoor side of the air conditioner should be checked regularly If they are clogged with dirt or soot they may be professionally steam cleaned a service available through a dealer Care and Maintenance Care and Maintenance Air Filter Cleaning The air filter should be checked at least twice a month to see if cleaning is necessary Trapped particles in the filter will build up and block the airflow This reduces the cooling capacity and also causes an accumulation of frost on the cooling coils 1 Open the inlet grille upward by pulling out the bottom of the inlet grille a In another case you can open the inlet grille downward by pulling out the top of the inlet grille b 2 Remove the air filter from the front grille assembly by pulling the air filter up or down slightly 3 Wash the filter using lukewarm water below 40 C 104 F c 4 Gently shake the excess water from the filter completely Replace the filter Mark A of inlet grille means opening direction CAUTION DO NOT operate the air conditioner without a filter because dirt and lint will clog it and A reduce performance 1 Pull down front grille from the ca
5. over the life of your air conditioner You ll find many answers to common problems in the chart of troubleshooting tips If you review our chart of Troubleshooting Tips first you may not need to call for service at all PRECAUTION e Contact the authorized service technician for repair or maintenance of this unit Contact the installer for installation of this unit e The air conditioner is not intended for use by young children or invalids without supervision Young children should be supervised to ensure that they do not play with the air conditioner When the power cord is to be replaced replacement work shall be performed by authorized personnel only using only genuine replacement parts Installation work must be performed in accordance with the National Electric Code by qualified and authorized personnel only Safety s Precautions Precautions To prevent injury to the user or other people and property damage the following instructions must be followed E Incorrect operation due to ignoring instruction will cause harm or damage The seriousness is classified by the following indications S AWARNI NG This symbol indicates the possibility of death or serious injury AC AUTION This symbol indicates the possibility of injury or damage to properties oe Ne E Meanings of symbols used in this manual are as shown below OQ Be sure not to do Be sure to follow the instruction
6. securely and firmly Install the unit where the sunlight does not shine directly on FOAM the unit There should be no obstacle such as a COOLED fence or wall within 50cm from the back of the cabinet AIR because it will prevent heat radiation of the condenser Restriction of outside air will greatly reduce the cooling B efficiency of the air conditioner 4 Install the unit a little obliquely outward not to leak the condensed water into the room about 10 15 mm or 1 4 bubble with level CAUTION All side louvers of the cabinet must remain exposed to the outside of the structure AWNING FENCE N HEAT f RADIATION g 10 15 mm Over 50 cm 1 4 Bubb le 1 Remove the 2 shipping screws from the back of the 3 Slide the air conditioner from the case by gripping case the base pan handle and pulling forward while bracing the case 2 Remove the 2 screws on each side of the case 4 Before installing the Air Conditioner back into the Keep these for later use case remove the white styrofoam shipping block from the compressor Applicable for some models Shipping screws White styrofoam block Install the Air Conditic 1 Slide the air conditioner into the case 5 Attach the front grille to the case by inserting the Reinstall the 2 screws removed earlier on each tabs on the grille into the slots on the front of the side of the case case Push the grille in until it snaps
7. binet top 3 Open the inlet grille 2 Push front grille s tips toward the cabinet in order to 4 Tighten the screw through the front grille into the insert front grille s tabs into the cabinet plate of the evaporator T 5 Close inlet grille opl pe Hardware Installation Hardware Installation Learning parts name prior to installation will help you understanding the installation procedure Features T DITTTTI IIIS y 1 CABINET 4 AIR DISCHARGE 10 EVAPORATOR 2 HORIZONTAL AIR 5 FRONT GRILLE 11 CONDENSER DEFLECTOR 6 AIR INTAKE INLET GRILLE 12 COMPRESSOR VERTICAL LOUVER 7 AIR FILTER 13 BASE PAN 3 VERTICAL AIR DEFLECTOR 8 CONTROL BOARD 14 BRACE HORIZONTAL LOUVER 9 POWER CORD 15 REMOTE CONTROLLER Foam Hardware Installation Installation Steps Read completely then follow step by step e The appliance shall be installed in accordance with national wiring regulation If a power plug isn t to be used provide a circuit breaker between power source and the unit as following picture Main Power source Circuit Breaker Use a circuit breaker or time delay Select the Best Locatic To prevent vibration and noise make sure the unit is installed
8. caping Check for open furnace floor registers and cold air returns e Set the air conditioner s vent to the closed position E Cooling coils have iced up e See Air Conditioner Freezing Up below oi E Ice blocks the air flow and stops Set the mode control at MED fan or high cool Air conditioner the air conditioner from cooling the with the thermostat at 1 or 2 Left side freezing uj oe os Set the mode control at HIGH fan or high cool with the high temperature ESPANOL LG P No MFL57207001 Printed in China After reading this manual keep it in a place easily accessible to the user for future reference
9. danger of fire or e Water may enter the unit and electric shock degrade the insulation It may cause an electric shock Turn off the power and Do not put a pet or house Do not use this appliance for breaker firstly when plant where it will be special purposes such as cleansing the unit exposed to direct air flow cooling pets foods precision machinery or objects of art e Since the fan rotates at high e This could injure the pet or e Itis an air conditioner not a speed during operation it plant precision refrigeration system may cause injury Always insert the filter Use a soft cloth to clean Do Do not drink water drained securely not use wax thinner ora from air conditioner Do Clean it every two weeks strong detergent not direct airflow at room occupants only e Operation without filters will e The appearance of the air It contains containments and cause failure conditioner may deteriorate will make you sick This change color or develop could damage your health surface flaws Operating Instructions Location and Function of Controls Conros The controls will look like one of the following 5 4 t 6 ax sT 2 8 A g Low Cool Thermostat Operation BEFORE RESTARTING KO Thermostat Warr THREE MINUTES Operation Operation Auto Swing i 1 i i a a FA COOL OFF Low coo Funci n Vent o Ret
10. e efficiency e You may hear the thermostat click when the compressor cycles on and off Water will collect in the base pan during high humidity or on rainy days The water may overflow and drip from the outdoor side of the unit e The fan may run even when the compressor does not Abnormal Operation Possible Causes What om Do E The air conditioner is unplugged Make sure the air conditioner plug is pushed completely into the outlet E The fuse is blown circuit breaker is Check the house fuse circuit breaker box and Air conditioner tripped replace the fuse or reset the breaker does not start A N PoE OTE E E Power failure e If power failure occurs push power button to OFF When power is restored wait 3 minutes to restart the air conditioner to prevent tripping of the compressor overload E Airflow is restricted e Make sure there are no curtains blinds or furniture blocking the front of the air conditioner H The thermostat may not be set e Turn the knob to a higher setting The highest high enough setting provides maximum cooling E TEMP Control set too higher e Set the TEMP control to a lower number Air conditioner number is Ha coolast E The air filter is dirty e Clean the filter at least every 2 weeks snou See the operating instructions section E The room may have been hot e When the air conditioner is first turned on you need to allow time for the room to cool down E Cold air is es
11. e low fan speed operation HIGH COOL 3K Permits cooling with the high fan speed operation LOW HEAT y4 Permits heating with the low fan speed operation HIGH HEAT XE Permits heating with the high fan speed operation CAUTION When the air conditioner has been performed its cooling operation and is turned off or set to the fan position wait at least 3 minutes before resetting to the cooling operation again Operating _ Instructions Remote Control Operation The controls will look like one of the following REMOTE CONTROL Controls CAUTION The Remote Control unit will not function properly if strong light strikes the sensor window of the air conditioner or it there are obstacles between the Remote Control unit and the air conditioner 1 POWER BUTTON Operation starts when this button is pressed and stops when you press the button again 2 AUTO SWING Optional The vertical louver swings horizontally by the automatic system and stops when you press the button again 3 ROOM TEMPERATURE SETTING BUTTON Control the room temperature within a range of 16 C to 30 C 4 FAN SPEED SELECTOR Select the fan speed in three steps High F3 gt Low F1 gt Med F2 gt High F3 5 OPERATION MODE SELECTION BUTTON Select Cooling Fan or Dehumidification mode with this button 6 ON OFF TIMER BUTTON Set the time of starting and stopping operation The timer is set by 1 hour 7 SIGNAL RECEIVER
12. in at the desired position of the vane e VERTICAL AIR DIRECTION CONTROL The vertical air direction is adjusted by moving the horizontal louver e Auto Swing Models The horizontal air direction is automatically controlled by setting the AUTO SWING switch to the ON position How to Attach Drain Par i The air conditioner employs a proper drain method whereby the condensed water moisture removed from the air is drained to the outside In very humid weather and for reverse cycle models in the reverse mode excessive condensate water removed from the air may cause some water to collect To remove this excess water you can install the drain pan as detailed below CABINET 1 Take the drain pan which is located in the air discharge 2 Remove the hole rubber from the base pan for some models 3 Install the drain pan to the right corner of the cabinet with 4 or 2 screws 4 Connect the drain hose to the outlet located at the bottom of the drain pan You can purchase the drain hose or tubing locally to satisfy your particular needs Drain hose is not supplied How to Connect a Drain A drain hole is provided at the rear of the air conditioner unit Fig 1 Select a drain method according to the following DRAIN PIPE 1 Remove the hole rubber from the base pan for some models sea DRAIN HOSE 2 Connect a drain hose to the drain pipe as shown in Fig 1 Fig 2 3 Or connect a pipe elbow to the
13. ing to the cooling operation again Thermostat sonal Weit Three Min Cooler Bef starti Thermostat O WY yk aK Warmer Cooler Thermostat Operation i Warmer Cooler ai Thermostat cee E AUTO SWING Optional ON A Air swing is operated while OPERATION knob is set to the COOL or HEAT position OFF Stops the operation of air swing E THERMOSTAT Turn the thermostat control to the desired setting The control position is a normal setting for average conditions You can change this setting if necessary in accordance with your temperature preference The thermostat automatically controls cooling or heating but the fan runs continuously whenever the air conditioner is in operation If the room is too warm turn the thermostat control clockwise If the room is too cool turn the thermostat control counterclockwise E HEATER 3 LAMP When the unit sets heating operation condition the green lamp is lighted When the frost settles on the heat exchanger of the outside defrosting is made automatically and the green lamp is turned off The unit may give a hiss and the fan motor stops for 1 to 10 minutes This should not be regarded as a problem After defrosting the heating operation begins again E OPERATION OFF Turns the air conditioner off LOW FAN x Permits the low fan speed operation without cooling heating LOW COOL sx Permits cooling with th
14. into place CAUTION The power cord must be A connected to an independent circuit The When you detach the front grille green wire must be grounded from the case push the grille to 2 Stuff the foam between the top of the unit and the your right side and pull it toward wall to prevent air and insects from getting into the you room 6 Lift the inlet grill and secure the front grille with a screw Lower the inlet grille into place 3 Before installing the front grille pull out the vent control lever located above the unit control knobs as shown ao 1 fyou want to pull out the filter upward open the inlet grille slightly Turn inside out the front grille Disassemble the inlet grille from the front grille with separating the hinged part by inserting a type screw driver tip Rotate the inlet grille 180 degrees and insert the hooks into the lower holes of front grille Then insert the filter 2 If you want to pull out the filter downward use the reversible inlet grille without change The grille is already assembled for that way Common Issues Common Problems and Solutions Troubleshooting Tips Save time and money Review the chart below first and you may not need to call for service Normal Operation e You may hear a pinging noise caused by water being picked up and thrown against the condenser on rainy days or when the humidity is high This design feature helps remove moisture and improv
15. rig WU s E OPERATION High Cool XK Med Cool 3 and Low Cool 3 provide cooling with different fan speeds Med Fan A or Low Fan G3 provides air circulation and filtering without cooling Off O turns the air conditioner off If you move the switch from a cool setting to off or to a fan setting wait at least 3 minutes before switching back to a cool setting Cooling Descriptions For Normal Cooling Select High Cool or Med Cool with the Operation knob at the midpoint of Thermostat knob For Maximum Cooling Select High Cool with the Operation knob at the highest number available on your Thermostat knob For Quieter amp Nighttime Cooling Select Low Cool with the Operation knob at the midpoint of Thermostat knob E THERMOSTAT The THERMOSTAT is used to maintain the room temperature The compressor will cycle on and off to keep the room at the same level of comfort When you turn the knob to a higher number the right side and the indoor air will become cooler The 5 or 6 position the middle position of arc is a normal setting for average conditions E AUTO SWING Optional Auto swing switch controls the horizontal air direction by air swing system not on all models ON A Auto swing is operated OFF Auto swing is not operated CAUTION When the air conditioner has been performed its cooling operation and is turned off or A set to the fan position wait at least 3 minutes before resett
16. shock Do not operate with wet hands or in damp environment e It will cause electric shock Do not allow water to run Leave the door closed while Do not operate the air into electric parts the air conditioner is conditioner if you smell gas running e It will cause failure of machine e It is not designed to coolthe It may cause explosion fire or electric shock entire house and burn ACAUTION E Installation Never touch the metal parts Do not block the inlet or Ensure that the outer case of the unit when removing outlet is not damaged by age or the filter wear e They are sharp and may e It may cause failure of If leaving appliance damaged cause injury appliance or accident there is concern of damage due to the falling of product E Operation Be cautious not to touch the Hold the plug by the head Turn off the main power sharp edges when when taking it out switch when not using it for installing a long time It may cause injury It may cause electric shock e Prevent accidental startup and damage and the possibility of injury iC M AH M eM a Do not place heavy object If water enters the product Do not clean the air on the power cord and take turn off the the power switch conditioner with water care so that the cord should of the main body of appliance not be pressed Contact service center after taking the power plug out from the socket e There is
Download Pdf Manuals
Related Search
Related Contents
分光放射照度計CL-500A Fargo DTC 1000 Samsung SL-M3820D User Manual 取扱説明書 - 三菱電機 here - Telecommunications Industry Association Copyright © All rights reserved.