Milwaukee MW500 User's Manual

image

Contents

1. SPECIFICATIONS AW Milwaukee MW500 RANGE 1000 mV RESOLUTION 1 mV ACCURACY 25 C 5 mV TYPICAL EMC DEVIATION 5 mV ORP ELECTRODE MA921B 1 included ENVIRONMENT 0 to 50 C 95 RH max BATTERY TYPE 9V alkaline included BATTERY LIFE approximately 300 hours of use DIMENSIONS 143 x 80 x 32 mm WEIGHT 220 g with battery meter only OPTIONAL ACCESSORIES M10000B Electrode rinse solution 20 mL sachet 25 pcs MA9015 Electrode storage solution 220 mL bottle MA9020 200 275 mV ORP solution 220 mL bottle MA921B 1 Platinum ORP electrode with 1 m cable WARRANTY This instrument is warranted from all defects in materials and manufacturing for a period of two years from the date of purchase The electrode is warranted for a period of six months If during this period the repair or replacement of parts is required where the damage is not due to negligence or erroneous operation by the user please return the parts to either dealer or our office and the repair will be effected free of charge Note We reserve the right to modify the design construction and appearance of our products without advance notice OLLO O0SMNLSI ANY Milwaukee USER MANUAL PORTABLE ORP METER MODEL MW500 Smart ORP Meter Pa M MW 500 ORP Meter range 1000 mV Smart ORP Meter OPERATION e The meter is supplied complete with a 9V battery Slide off the battery compartment cover located
2. battery replacement is required Battery replacement must only take place in a non hazardous area using an alkaline 9V battery Turn the meter off slide the battery compartment cover located at the rear of the meter off and replace the 9V battery with a new one Make sure the battery contacts are fully engaged in the connector seat the battery in its compartment and replace the cover oO MADE IN EUROPE ROMANIA Milwaukee Rocky Mount NC USA
3. on the back of the meter Install the battery into the battery clip connector while observing polarity e Always remove the electrode protective cap before taking any measurement If the electrode has been left dry soak the tip in storage solution for a few minutes to reactivate it e Connect the ORP electrode to the BNC socket on the top of the meter e Immerse the tip 2 5 cm of J l J the ORP electrode into the sample e Turn the instrument on by pressing the ON OFF key e Allow the reading to stabilize before taking measurements e After use switch the meter off and store the electrode with a few drops of storage solution in the protective cap e The meter is factory calibrated ORP electrodes are interchangeable and no NA mV calibration is needed when they are replaced MAINTENANCE M MW 500 ORP Meter range 1000 mV Smart ORP Meter e The surface of the ORP electrode must always be clean Use M10000B rinse solution for this purpose If needed clean the Platinum tip with very fine abrasive paper When not in use the tip reference junction of the electrode should always be kept moist and safe from any mechanical stress BATTERY REPLACEMENT When the battery becomes weak the meter will display 3 the low battery indicator The battery has about 50 hours of working time left A low battery will result in unreliable measurements Prompt

Download Pdf Manuals

image

Related Search

Related Contents

  Spersacarpine® 2%  Wiring  Synway TEJ Series User Manual  American Standard 047007-0070A Indoor Furnishings User Manual  Istruzioni d`Uso - Amazon Web Services  

Copyright © All rights reserved.
Failed to retrieve file