1. Milwaukee USER MANUAL PORTABLE uP BASED pH METER MODEL MW102 Smart pH Meter J Milwaukee 7 HOLD CAL CFM pH Temp Meter Smart gH Meter BR S ix WARRANTY This instrument is warranted from all defects in materials and manufacturing for a period of two years from the date of purchase The electrode is warranted for a period of six months If during this period the repair or replacement of parts is required where the damage is not due to negligence or erroneous operation by the user please return the parts to either distributor or our office and the repair will be effected free of change Note We reserve the right to modify the design construction and appearance of our products without advance notice Milwaukee OPERATION e The meter is supplied complete with a 9V battery Slide off the battery compartment cover on the back of the meter and install the battery into battery clip connector while observing polarity e Always remove the electrode protective cap before taking any measurement If the electrode has been left dry soak the tip bottom 2 5 cm in rinse solution M10000B for a few minutes to reactivate it e Connect the pH electrode and the temperature probe to the sockets on the meter s top The Milwaukee temperature probe fa ed can be used ri os inde
2. 4 01 MA9004 for measuring in the acid range pH lower than 7 or pH 10 01 MA9010 for measuring in the alkaline range pH higher than 7 Use two beakers for each reference solution One beaker for rinsing the electrode the other for calibration This way contamination between solutions during calibration is minimized B Procedure Offset calibration e Remove the electrode protective cap and rinse the tip with some pH 7 01 solution then immerse the electrode tip and the temperature probe into a pH 7 01 buffer solution e Press the CAL key to EAA enter the Calibration x Inn mode The display AU flashes pH 7 01 and the hourglass lights up e Wait till the hourglass symbol on the display turns off and the pH tag stops blinking then press su SAT H the CFM key to Un H I confirm the offset _ ITN calibration Note Pressing the CAL key again will change the buffer value allowing a single point calibration at pH 4 01 or pH 10 01 Slope calibration After completing the pH 7 01 calibration the next buffer pH 4 01 will flash on the display e Press CAL key to display pH 10 01 if desired e Rinse the pH electrode and the temperature probe in the rinse buffer beaker then immerse them into the second buffer beaker MA 9004 pH 4 01 T W e Wait till the hourglass symbol on the LCD turns off then press the CFM key to conf
3. irm the slope calibration Notes e To exit the calibration mode turn the meter off by pressing the ON OFF key e To perform a single point calibration offset at pH 7 01 press the ON OFF key when the second buffer is displayed After battery replacement the meter displays the Cir message and recalibration is needed Milwaukee BATTERY REPLACEMENT When the battery becomes weak a reliable measurement can not be guaranteed The meter will display Eb for a while and then turn off Prompt battery replacement is required Battery replacement must only take place in a non hazardous area using a 9V alkaline battery Turn the meter off slide the battery compartment cover located at the rear ml of the meter off and PEE replace the 9V battery Lsi with a new one 5j Make sure the Si battery contacts e are fully engaged in the connector seat the battery in its CE compartment and Sr S replace the cover OPTIONAL ACCESSORIES MA 9004 pH4 01 buffer solution 220 mL bottle MA 9007 pH7 01 buffer solution 220 mL bottle MA9010 pH10 01 buffer solution 220 mL bottle MA 9015 Electrode storage solution 220 mL bottle MA 9016 General cleaning solution 220 mL bottle M10000B Rinse solution 20 mL sachet 25 pcs MA911B 1 pH electrode with BNC connector and 1 m cable MA830R Temperature probe MA950 Portable meter wal
4. l mounting kit SPECIFICATIONS RANGE RESOLUTION ACCURACY 25 C TYPICAL EMC DEV TEMPERATURE COMPENSATION MW102 2 00 to 16 00 pH 5 to 70 C 0 01 pH 0 1 C 0 02 pH 0 5 C 0 02 pH 0 5 C Automatic 0 to 70 CALIBRATION Automatic at 1 or 2 points pH ELECTRODE TEMPERATURE PROBE MA911B 1 included MA830R included ENVIRONMENT 0 to 50 C RH 95 max BATTERY TYPE 1 x 9V alkaline included BATTERY LIFE approx 750 hours of use AUTO OFF DIMENSIONS WEIGHT after 8 minutes of non use 143 x 80 x 32 mm 220 g with battery ISTMW102 01 10
5. pendently to f E take temperature 7 MW 102 pH Temp Meter measurements or it can be used in conjunction with the pH electrode to utilize the meters ATC capability e Turn the instrument on by pressing the ON OFF key e Before taking any measurements make sure that the meter has already been calibrated Immerse the tip 2 5 cm of the pH electrode and the temperature probe into the sample and stir gently The pH measurement is ready when the hourglass symbol stops blinking e To display the mea sured temperature UJ press and hold the rao he C key When the key is released the display will return to the pH reading e The HOLD function is activated by pressing the HOLD key The UP measured value is frozen on the display and the HOLD tag lights up Release HOLD by pressing HOLD key again e After completing measurements ER switch the meter off and store OFF the electrode with a few drops of storage solution in the protective Lf cap e Error message on display e Blinking full scale value reading is over range e Eb battery low voltage indication e Ec wrong buffer solution e Clr the calibration data have been lost and recalibration is needed CALIBRATION PROCEDURE A Preparation Select two pH calibration buffers pH 7 01 and a second to bracket your measurement range 1 pH 7 01 MA9007 2 pH

Download Pdf Manuals

image

Related Search

Related Contents

  Touch & Crawl™ Friend - Fisher  Samsung SGH-S500 دليل المستخدم  TR3CF マネージャ Version1.10 取扱説明書  GSM REMOTE CAMERA User Manual  Peerless Industries PARAMOUNT PT660 User's Manual  Serv de X vidor Xerox r de x imp resió ón Fr reeFlow  Manual técnico y de instalación  Samsung SL-M4580FX Εγχειρίδιο χρήσης  Navilock NL-6004P  