Home
Miele DA 8-2 User's Manual
Contents
1. Installation instructions Do not install the DA 8 2 directly next to a gas hob This extractor is designed for installa tion between Combiset appliances It should always be installed between two appliances such as the grill and deep fryer m Prepare the countertop cut out as il lustrated Dimension B will vary depending on how many combisets are in stalled The following chart gives dimension B for a variety of 2 zone ie KM 88 2 and 4 zone ie KM 93 2 combinations 14 Depth Width in Dimen mm sion B in mm 2 zone Combiset 1 combise 490 265 2 combisets 490 558 3 combisets 490 851 4 combisets 490 1144 5 combisets 490 1437 4 zone Combiset 1 combisets 490 560 2 combisets 490 1143 3 combisets 490 1728 Combination One 2 zone one 4 zone 490 851 Two 2 zone one 4 zone 490 1143 Three 2 zone one 4 zone 490 1437 One 2 zone two 4 zone 490 1436 Two 2 zone two 4 zone 490 1729 Extractor e g DA 8 2 For installation between two appliances Dimension B increases by 90 mm For installation at the end of a combination Dimension B increases by 98 mm Depth Width in Dimen inches sion B in inches 2 zone Combiset 1 combise 19 5 16 10 7 16 2 combisets 19 5 16 22 3 combisets 19 5 16 33 1 2 4 combisets 19 5 16 45 1 16 5 combisets 19 5 16 56 9 16 4 zone Combiset 1 combisets 19 5 16 22 1 16
2. fire hazard Do not use a steam cleaner to clean the extractor The steam could penetrate to electrical components and cause a short circuit For the installer and electrician Ensure that the electrical connec tion in the house and the details on the data plate correspond Do not install the extractor beside appliances burning solid fuel All ducting pipework and fittings must be of non flammable material The appliance must not be con nected to a chimney or vent flue Neither should it be connected to duct ing which ventilates rooms with fire places If exhaust air is to be vented into a chimney or ventilation duct no longer serving other purposes seek professional advice Ensure there is sufficient ventilation in the room when the extractor is in operation When using the extractor at the same time as other heating appliances which depend on the air in the room e g gas oil or coal fired heaters con tinuous flow or other water heater gas cooktop or gas oven make certain that ventillation is adequate as the ex tractor will remove air from the room which these heaters need for combus tion In order to ensure safe operation and to prevent the exhaust gases of the heating appliances from being drawn into the room when the extractor and heater are in operation simultaneously an underpressure of 0 06 psi 4pa is the maximum permissible in the room Ventilation can be maintained by air in lets in
3. 2 combisets 19 5 16 45 3 combisets 19 5 16 68 1 16 Combination One 2 zone one 4 zone 19 5 16 33 1 2 Two 2 zone one 4 zone 19 5 16 45 Three 2 zone one 4 zone 19 5 16 56 9 16 One 2 zone two 4 zone 19 5 16 56 1 2 Two 2 zone two 4 zone 19 5 16 68 1 16 Extractor e g DA 8 2 For installation between two appliances Dimension B increases by 3 9 16 For installation at the end of a combination Dimension B increases by 3 7 8 Installation instructions m Remove the ventilation grill and grease filter m Unscrew the frame 2 screws at the front and remove m Install the extractor into the cut out from below the countertop so that the protruding front edge rests on the countertop m Raise the rear of the unit and place the extractor mounting bracket on the countertop m Lower the extractor onto the bracket and align the unit in the cut out Replace the frame and screw it into the countertop along with the rear mounting bracket m Secure the front of the unit by tighte ning the clamp from underneath the countertop m Replace the two frame mounting screws m Install the control panel and control knob m Connect the vent duct to the extrac tor and connect the appliance to the power supply When installing more than one com biset a stainless steel spacer bar must be placed between units It is supplied with its own installation instructions 15 Exhaust connectio
4. An opening of at least 135 mm 5 5 16 diameter must be cut in the kitchen cabinet in order to allow the exhaust ducting to pass through 330 130 Mount the fan so that the impeller cannot be inadvertently reached by hand m The exhaust ducting should be at tached to the exhaust connection using the supplied hose clamp Exhaust connections Calculation of exhaust ducting A pipe diameter of 5 should ensure trouble free extraction up to a total pipe length of 5 4 meters 17 1 2 ft Determine the total pipe length as fol lows m Measure the total length of ducting needed m Add the length of additional ducting to this figure according to the num ber and type of bends see table below Note If the exhaust ducting will run through rooms ceiling space etc where there may be variations in temperature the problem of sweating or condensation will have to be addressed The exhaust ducting may need to be in sulated Example Wall vent 1 1 4m 43 Flexible 90 bend 2 0 3m 12 Flexible pipe 3 1 0m 39 Flexible 45 bend 4 0 2m 8 Total pipe length 2 6m 81 2 With a total pipe length of 8 2 ft 102 the exhaust is within the effec tive range Air flow rates Setting 1 240 m h 145 CFM Setting 2 465 m h 275 CFM Type of bend Angle Radius of Radius of Effective Effective of bend bend bend pipe length pipe l
5. Miele Operating instructions for the DA 8 2 Extractor M Nr 03 997 810 Description of the appliance Description of the appliance The DA 8 Extractor draws cooking va Data plate pors in through the grease filter and exhausts ERA tothe onisi Because the data plate is no longer visible once the appliance has been in Ventilation grill stalled a 2nd data plate is supplied It Grease filter should be placed into the space pro vided on page 11 of these instructions 3 5 120 mm diameter exhaust connection Extraction warning label Do not install the DA 8 2 directly Control knob next to a gas hob Control panel Help protect our environment Disposal of packaging The transport and protective packing is mostly manufactured from the following re usable materials Corrugated paper cardboard mostly from recycled materials Polyethylene foil PE partly from secondary raw materials Rather than throwing these materials away please take them to the nearest recycling center for specific waste Disposal of your old machine Old machines contain materials which can be recycled Please contact your local recycling center or scrap mer chant about potential recycling pro grams before disposing of the ap pliance Read the notes on page 8 before dis posing of the appliance Contents Description of the appliance 2 Help pr
6. ctor meets all statutory safety requirements The electrical safety of this ap covered by a saucepan or pot pliance can only be guaranteed Heat given off by the flames could when continuity is complete between otherwise damage the extractor the appliance and an effective grounding system It is imperative that this basic safety requirement is met If there is any doubt have the electrical system of the house checked by a qualified electrician The manufacturer cannot be held re sponsible for damage caused by the lack or inadequacy of an effective grounding system Installation and repairs should only be performed by qualified and trained personnel Repairs by unquali fied personnel could be dangerous Do not connect the appliance to the main electrical supply using an extension cord Extension cords do not guarantee the required safety of the ap pliance Warning and safety instructions Never leave the unit unattended when cooking with oil or fat Very hot oil can ignite and damage the ex tractor Try to prevent drops of soup sauce etc or residues from the grease filter from finding their way into the interior of the appliance Should this occur however cleaning should only be performed by the Miele Service Department since the fan cas ing will have to be taken completely apart Do not use the extractor without the grease filter in place Clean the grease filter regularly An over greasy filter is a
7. ength in mm in inches in meters in inches Flexible pipe 45 120 4 3 4 0 2 8 90 120 4 3 4 0 3 12 1 0 39 Wall vent 18 19 Miele Appliances Inc National Headquarters 22D Worlds Fair Drive Somerset NJ 08873 Phone 732 560 0899 or 800 843 7231 Fax 732 560 9649 Internet htto Awww miele USA com Southeast Regional Headquarters 6400 Congress Avenue Suite 1700 Boca Raton FL 33487 Phone 561 995 8030 Fax 561 995 8083 West Coast Regional Headquarters 680 Eighth Street Suite 168 Sobel Building San Francisco CA 94103 Phone 415 241 6820 Fax 415 241 6822 REGIONAL SERVICE 800 245 8215 Southern California Showroom 189 North Robertson Blvd Beverly Hills CA 90211 Phone 310 855 9470 Fax 310 358 0238 Mid West Regional Headquarters 3100 West Dundee Road Suite 901 Northbrook IL 60062 Phone 847 714 9433 Fax 847 714 9434 Alteration rights reserved 22 001 Miele Miele Limited Canadian Head Office 55G East Beaver Creek Road Richmond Hill Ontario L4B 1E5 Phone 905 707 1171 Fax 905 707 0177 Toll Free 1 800 565 6435 Internet www miele ca E Mail info miele ca general enquiries E Mail service miele ca technical service BC Regional Sales Office 3731 North Fraser Way Unit 200 Burnaby British Columbia V5J 5J2 Phone 604 434 1300 Fax 604 434 1309 CDN USA 4698
8. given on the back page When contacting the Service Depart ment please quote the Model and Ser ial No of the appliance Electrical connection Electrical connection CDN The extractor is supplied with a 1 10 m power supply cable ready for connec tion to a 120 VAC 60 Hz supply The rated load is 110 W Fuse rating is 10 A Caution Make sure the power supply is OFF during installation Important The wires of the power cord are co lored as follows Green ground Black live White neutral WARNING THIS APPLIANCE MUST BE GROUNDED 12 Electrical connection USA The extractor is supplied with a 4 ft cord ready for connection to a 120 VAC 60 Hz power supply Connec tion should be made in an appropriate junction box The rated load is 110 W Fuse rating is 10 A Important The wires of the power cord are color coded as follows Green Yellow ground Blue neutral Brown live As the colors of the wires in the power supply cord of this appliance may not correspond with the colors of the wires in your junction box proceed as follows The green and yellow wire must be con nected to the ground wire The blue wire must be connected to the neutral wire The brown wire must be connected to the hot wire WARNING THIS APPLIANCE MUST BE GROUNDED Appliance dimensions 8 14 3 16 ET 360 e 2 S 33 3 8 0 3 16 1 ee 19 5 1 a 78
9. n Please read the Warning and Safety Instructions to avoid the danger of toxic fumes The DA 8 extractor should be in stalled in accordance with local and national building regulations The exhaust connection should be made into a vent shaft or chimney that is not in use using non flammable ex haust ducting to the outside by using a wall vent kit These kits are available from the Miele Parts Department Installation should only be per formed out by a suitably qualified and trained person 16 The exhaust ducting should be as short and straight as possible The use of angled pipes should be avoided as this will reduce the air flow of the extractor Only use ducting made of non flammable material The exhaust ducting may be angled either to the left right or downwards If the ducting is run beneath the cabinets it requires a toe kick height of at least 5 15 16 If the ducting is run horizontally en sure that there is a gradient of at least 1 8 per foot so that condensa tion will not run into the appliance Vent connection variations 260 140 a In connection examples B and C neither the KM 88 nor the KM 89 can be installed to the left of the DA 8 since it will not be possible to place a container beneath the oil drain valve 190 210 0 1 4 5 1 2 Exhaust connections m
10. otect our environment 4 Warning and safety instructions 6 Operation ALES ASP ee ere te eT Ak a eT ne nn See 9 Cleaning and care 10 After Sales Service 11 Electrical connection 12 Appliance dimensions 13 Installation instructions 14 Exhaust CoOnnection 2 eh a a ts LOM RA OR Et ee 16 Exhaust connections 17 Warning and safety instructions Before servicing disconnect the power supply by removing the fuse or tripping the circuit breaker Grasp the plug not the cord when unplugg ing from the wall Before installation and before using the appliance for the first time read these operating instructions care fully to avoid the risk of accidents and damage to the appliance Do not use an open flame beside The appliance is intended for do the extractor When turned on the mestic use only extractor could draw flames into the fil ter Grease particles trapped in the fil DE parlor smal ehidien play wits ter will then present a fire hazard the extractor or its controls When the extractor is installed beside a gas cooktop ensure that the burners being used are always This extra
11. uble free oper ation of the extractor fan An over greasy filter is a fire hazard m To remove the grease filter the venti lation grill 1 must be removed m Carefully withdraw the grease filter 2 10 Make sure that no particles from the grease filter fall into the interior of the appliance If this does happen the Service Department will have to be called to clean the appliance as the fan casing will need to be dis mantled Loosen both screws on the grease fil ter and remove the drip tray Clean the grease filter the ventilation grill and the drip tray By hand in a solution of hot water and detergent using a nylon brush or In a dishwasher the grease filter the ventilation grill and the drip tray should be placed in the bottom bas ket Ensure that the spray arm is not obstructed When clean and dry replace the drip tray on the grease filter and re install it in the appliance m Replace the ventilation grill Control panel Control knob The control panel and control knob should be cleaned in a solution of hot water and detergent and dried using a soft cloth Do not use abrasive cleaning agents as these will scratch the sur face material In the event of problems you cannot correct yourself please contact m Your Miele Dealer or m The Miele Service Department Space for enclosed data plate After Sales Service The address of the nearest Service De partment is
12. windows doors and outside walls or by other means such as en suring that the extractor can only be turned on when the heating appliance is off and vice versa Keep these operating instructions in a safe place for future reference and pass them on to future owners if ap plicable Warning and safety instructions Disposal of an old appliance Before disposing of an old ap pliance cut the cable off the ap pliance as close to the housing as possible The plug and cord should be disposed of and not used elsewhere in the house electric shock hazard Text highlighted in boxes is of par ticular importance and should be read in conjunction with the warning and safety instructions Operation Turn the extractor on before starting to m Select a power setting strong Cook enough to clear the air m Turn the control knob clockwise Setting 1 for normal operation Setting 2 for removing heavy cooking odors After cooking m Turn the control knob counter clock wise to 0 Cleaning and care Before cleaning the extractor dis connect it from the main electrical supply pull out the plug or trip the circuit breaker Grease filter A re usable metal grease filter is used to remove solid particles oil dust etc from kitchen vapors preventing soiling of the extractor fan The grease filter can be cleaned ina dishwasher or by hand The grease filter should be cleaned regularly to ensure tro