Home

METRObility Optical Systems 3508-11 User's Manual

image

Contents

1. Power _____ Fpx Lancast 8 Port CenturySwitch 11 Troubleshooting Cabling Problems Improper cabling is the primary cause of most network problems particularly for 100Base TX and 100Base FX networks Use only the specified twisted pair or fiber optic cables to avoid most cabling problems e Flat telephone extension cables or Category 3 wires are not the same as Category 5 twisted pair cables and will not function on Fast Ethernet networks There is a wiring problem if the Link Act LED does not illuminate when the RJ 45 plug from a workstation is inserted into the port jack Correct the break in the cable or replace the cable before proceeding If a workstation workstation A does not function while workstations con nected to other ports on the CenturySwitch operate normally remove an RJ 45 plug from a functioning port with a functioning workstation workstation B and insert it into the suspect port If workstation B still works the prob lem may be in workstation A or in the wiring However if workstation B does not work the CenturySwitch may have a defective port Even if you suspect a defective port continue testing Improperly wired workstations may appear functional especially if they are located near the switch Some times a port connected to an improperly wired workstation functions mar ginally while another port does not work at all e Once you have established that the CenturySwitch is
2. 1 16 User Guide Product Safety EMC and Compliance Statements This equipment complies with the following requirements e UL e CSA TUV EN60950 safety FCC Part 15 Class A EN55022 Class A emissions EN50082 1 immunity e IEEE 802 3 e IEEE 802 3u IEEE 802 3x IEC 825 1 Classification e Class 1 Laser Product This product shall be handled stored and disposed of in accordance with all gov erning and applicable safety and environmental regulatory agency requirements The following FCC and Industry Canada compliance information is applicable to North American customers only USA FCC Radio Frequency Interference Statement This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communication Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense Caution Changes or modifications to this equipment not expressly approved by the party responsible for compliance could void the user s authority to operate the equ
3. tel 603 880 1833 fax 603 594 2887 www metrobility com 5660 350001 001 D 8 01
4. 8 0E F provides a multimode MT RJ connector These modules support a maximum segment length of 2km 10 100 Ethernet Switch 12345678 Link Act 00000000 100Mbps 00000000 Power 000000000 ll px 100BASE FX 10 100 Ethernet Switch 12345678 Link Act 00000000 100Mbps 00000000 Power 000000000 ll px 7 When making fiber optic connections with two cables be sure that the transmit TX connector on the CenturySwitch connects to the receive RX connector of the device Conversely be sure that the transmit TX connector of the device connects to the receive RX connector on the CenturySwitch Once power is applied to the unit use the Link Act LED for Port 8 to verify correct segment connectivity The LED illuminates if an active device is connected to the other end of the cable s 8 Installation Guide Apply Power The CenturySwitch is equipped with an internal 100 240V 50 60Hz 25W power supply When making power connections connect the power cord to the input jack located on the back of the switch before making the AC connection to the outlet AC Power Socket IMPORTANT f the CenturySwitch loses power wait at least 10 seconds before applying power again The CenturySwitch is shipped with a standard North American 3 pin power cord which is UL USA CSA or CUL Canada listed or ap proved For installation in regions outside of North America replace the powe
5. Lancast 8 Port CenturySwitch Installation amp User Guide Model 3508 11 Lancast CenturySwitch 8 Port CenturySwitch 3508 11 8 port switch with 10 100 TX module Fiber Optic Modules 3508 03 F ____ 100Base FX multimode SC 3508 04 F ____ 100Base FX singlemode SC 15km 3508 05 F ____ 100Base FX multimode ST 3508 07 F ____ 100Base FX singlemode SC 40km 3508 0E F ____ 100Base FX multimode MT RJ This publication is protected by the copyright laws of the United States and other countries with all rights reserved No part of this publication may be reproduced stored in a retrieval system translated transcribed or transmitted in any form or by any means manual electric electronic electromagnetic mechanical chemical optical or otherwise without prior explicit written permission of METRObility Optical Systems Inc 2000 01 METRObility Optical Systems Inc All rights reserved Printed in USA 8 Port CenturySwitch Installation amp User Guide Froduc OWuW iis E a 4 Installation Gilde iaia 5 STEP 1 Unpack the Lancast CenturySwitch 52 aka a Dak sa kak a 5 STEP2 Choosea Locations tania 5 STEP 3 Connect tothe Network sasa 6 STEP 4 Install the Fiber Module Optional eze Si SLEP S APPI FOW pin k ra NENA W da g n An k ee NON dib h MARA 9 User Gilde uil 11 LED OPE go x l QAWE letale 11 Tioubleshooim alain 12 Topology Solutio
6. ed above 10 32 screw size is recommended Lancast 8 Port CenturySwitch 5 Connect to the Network The Lancast CenturySwitch is compatible with both 10Base T and 100Base TX devices Network connections are made by simply plugging the cables into the RJ 45 port connectors on the front panel as shown in the figure below Each port supports a maximum segment length of 100 meters over Category 5 UTP cables for 100Base TX segments and Category 3 4 or 5 UTP cables for 10 Base T segments Once power is applied to the unit use the individual Link Act LEDs to verify correct segment connectivity 2345678 1 Link Act 00000000 100Mbps 00000000 Power 000000000 _ Fox 7 Fixed Ports The CenturySwitch provides seven fixed RJ 45 ports with connectors for devices wired crossover The ports are labeled 1x through 7x These dual speed ports are 10 100Mbps auto sensing and will automatically detect and operate at the speed of the connected device Module Port Port 8 provides two RJ 45 connectors which support a device wired either crossover MDI X or parallel MDI ID IMPORTANT Do not connect devices to both the MDI X and MDI II connectors at the same time This can damage the unit and void its warranty 6 Installation Guide Install the Fiber Module Optional Proceed to Step 5 if you are not using a fiber module The standard 10 100 TX module installed in the CenturySwitch may be replaced by a 100Base FX module R
7. efer to the listing inside the front cover for all available options Set the Backpressure Jumper Prior to installing the fiber module you must set the flow control backpressure jumper labeled JP2 on the printed circuit board See the diagram below for its location e Connect jumper pins 1 and 2 to enable backpressure e Connect jumper pins 2 and 3 to disable backpressure default Jumper JP2 Set the Duplex Mode Switch Each fiber module can be configured for half duplex HDX or full duplex FDX operation by means of the slide switch located on the front panel This switch should be set before applying power The default setting on the modules is FDX full duplex Install the Module To install your FX module first remove the TX interface by turning the two thumb screws counterclockwise and withdrawing the card Replace it with the new module Tighten both screws firmly to attach the fiber module to the CenturySwitch Lancast 8 Port CenturySwitch 7 Connect to the Network The 3508 04 F and 3508 07 F modules provide a pair of singlemode SC connectors The 3508 04 F supports a maximum segment length of 15km and the 3508 07 F supports a maximum segment length of 40km Za 10 100 Ethernet Switch 12345678 Link Act 00000000 1x 2x 3x 4x 5x 6x 7x SER LL LL Power U Fox The 3508 03 F and 3508 05 F modules provide a pair of multimode SC and ST connectors respectively The 350
8. gnosed by using the LEDs as described below Power LED is OFF when CenturySwitch is connected to the AC source e Defective fuse e Incorrect AC voltage e Defective switch Link Act LED is OFF at a port e Faulty node or wiring connection when RJ 45 plug is inserted a clicking sound should be heard No link signal is received from the remote device CenturySwitch does not work If the switch does not function or is experiencing interference 1 e your site is located near a radio station transmitter etc try using shielded twisted pair STP cables instead of UTP cables Self diagnostic test The CenturySwitch performs a self diagnostic test at power on LED indicators go to their normal status if no problem occurred To reset or restart the CenturySwitch unplug it from the AC source and wait 10 seconds before applying power again CAUTION Circuit devices are sensitive to static electricity which can damage their delicate electronics Dry weather conditions or walking across a carpeted floor may cause you to acquire a static electric charge To protect your device always e Touch the metal chassis of your computer to ground the static electrical charge before you pick up the device Pick up the device by holding it on the left and right edges only Lancast 8 Port CenturySwitch 13 Topology Solutions 14 User Guide CenturySwitch apo mg te CenturySwitch a8 CenturySwitch ose BETI EH mg u Intelligen
9. ipment Canadian Radio Frequency Interference Statement This Class A digital apparatus meets all requirements of the Canadian Interfer ence Causing Equipment Regulations Cet appareil num rique de la classe A respecte toutes les exigences du R glement sur le mat riel brouilleur du Canada Lancast 8 Port CenturySwitch 17 Warranty and Servicing METRObility Optical Systems Inc warrants the Lancast CenturySwitch to be in good working order for a period of three years from the date of METRObility shipment Should the unit fail anytime during said three year period METRObility will at its option replace or repair the product This warranty is limited to defects in workmanship and materials and does not cover damage from accident disaster misuse abuse or unauthorized modifications Under no circumstances will METRObility be liable for any damages incurred by the use of this product including but not limited to lost profits lost savings and any incidental or consequential damages arising from the use of or inability to use this product If the product was purchased from an authorized METRObility dealer limited warranty service may be obtained by returning the product to the dealer Return the product in its original shipping container or equivalent pre insured and with proof of purchase 18 User Guide Lancast 8 Port CenturySwitch 19 gt METRObility optical systems 25 Manchester Street Merrimack NH 03054 USA
10. kmounting hardware 2 mounting brackets 4 screws Power cord Your order has been provided with the safest possible packaging Inspect it carefully If you discover any shipping damage notify the carrier and follow their instructions for damage and claims Save the original shipping carton if return or storage of the unit is necessary Choose a Location The CenturySwitch is intended for use in normal office environments and requires few restrictions on placement Select a location that is within 6 feet of an AC power source and less than 100 meters from servers workstations or other connected devices Do not connect the unit to a power strip Be sure the location allows for adequate ventilation with a clearance of at least 1 2 on the sides of the unit Be sure the location is as far away as possible from electrical noise generating equipment such as copiers electrostatic printers or other motorized devices The CenturySwitch is designed to be mounted in a standard 19 inch equipment rack Use the rackmounting hardware included with the unit to secure the mounting brackets to the unit Use the separate screws provided with the equipment rack to mount the unit in the rack Be sure that the mounting of the unit does not impose a hazardous condition due to uneven mechanical loading The CenturySwitch can also be installed on a tabletop For tabletop installation select a location with the power and ventilation requirements cit
11. ns sa ei Renee as 14 Technical Specificanons alli 15 Product Safety EMC and Compliance Statements 17 Waranty Qe Servi CW ooa eee a e n E kak we sdussie ai 18 Lancast and CenturySwitch are registered trademarks of METRObility Optical Systems Inc All other trademarks appearing in this manual are the property of their respective owners The information contained in this document is assumed to be correct and current The manufacturer is not responsible for errors or omissions and reserves the right to change specifications at any time without notice Thank you for choosing the Lancast CenturySwitch Designed to meet the needs of today s growing networks the Lancast 8 Port CenturySwitch is a compact low cost switch featuring a unique replaceable port module The standard unit provides eight auto negotiating 10 100 TX ports including one modular port with two connectors to support either a crossover or parallel connection The TX interface may be replaced by an optional 100Base FX module METRO bility offers FX modules with SC ST and MT RJ multimode connectors in addition to SC singlemode connectors which support network segments up to 15 or 40km For added versatility all FX modules include two user selectable controls to configure the port s duplex mode and to set the backpressure flow control By breaking up the collision domain and multiplying network performance the Lancast CenturySwitch delivers
12. r cord with a cord approved by the appropriate safety agencies Any cord used must have a CEE 22 standard V female connector on one end and meet IEC 320 030 specifications European power cords must be harmonized and designated with a HAR marking on the cord Jacket to comply with the CENELEC Harmonized Document HD 21 The CenturySwitch does not have a power switch After connecting the unit to the AC receptacle check that the PWR power LED is illumi nated A steady green light indicates the unit is receiving power Once power is applied to the unit use the individual Link Act LEDs on the front panel to verify correct segment connectivity Lancast 8 Port CenturySwitch 9 10 Installation Guide This section contains more detailed information regarding the operating features of the Lancast CenturySwitch LED Operation The functional descriptions of the LED indicators are listed below The port LEDs report the status of their corresponding ports labeled 1 through 8 LED Name Color Status Function System LED Power Unit is powered ON Per Port LEDs Connection with remote ON e device is good Link Act Green Blinking Blinking TX traffic is present No connection to remote device 100Mbps speed is active 100Mbps Green Ca 10Mbps speed is active oN Full duplex mode is active FDX Amber or Half duplex mode is active anca st CenturySwitch 12345678 Link Act 100Mbps
13. t 100Mbps 7500 Chassis Enterprise Switch piani Lea Copper Fiber Optic Technical Specifications Data Rate 10Base T ports 100Base TX ports 100Base FX ports Switching Performance Buffer memory Packet filtering forwarding rate MAC addresses Network Connections Twisted Pair Interface Connector Supported link length Cable type 10Mbps segments 100Mbps segments Multimode Fiber Optic Interface Connector Supported link length Cable type Singlemode Fiber Optic Interface Connector Supported link length Cable type Power Requirements Auto sensing Environmental Operating temperature Storage temperature Operating humidity 10Mbps half duplex 20Mbps full duplex 100Mbps half duplex 200Mbps full duplex 100Mbps half duplex 200Mbps full duplex 512KB for 8 ports 148 800 packets sec 100Mbps 14 880 packets sec 1OMbps SK Shielded RJ 45 8 pin 100m Category 3 4 or 5 UTP Category 5 UTP SC ST or MT RJ up to 2km full duplex 50 125 62 5 125 or 100 140um F O SC up to 15km full duplex 3508 04 F up to 40km full duplex 3508 07 F 8 3 125 8 7 125 9 125 or 10 125um F O 100 240V AC 50 60 Hz 25W 0 C to 50 C 25 C to 60 C 5 to 90 non condensing Lancast 8 Port CenturySwitch 15 Physical Dimensions 13 W x 6 75 D x 1 75 H Weight 4 lb Regulatory Compliance IEEE 802 3u and 802 3x TUV Safety UL CSA EN60950 EMC FCC Part 15 Class A EN55022 Class A EN50082
14. the ideal solution for easing network congestion problems on existing shared hub networks Use the CenturySwitch to increase overall network transmission speed and to improve efficiency to accommodate high bandwidth applications such as imaging multimedia and CAD CAM The CenturySwitch includes an universal internal power supply and is perfect for stand alone or rackmount use in any office environment Key Features Designed for high performance versatility and cost effectiveness the CenturySwitch offers the following key features Eight 10 100Mbps auto negotiating RJ 45 ports including one MDI X MDI II modular port e Optional multimode or singlemode 100Base FX interface Full half duplex switch on all FX modules e Backpressure flow control for half duplex on optional FX interfaces IEEE 802 3x compliant for flow control on all TX ports Diagnostic LED indicators Store and forward switching 148 800 packets sec full wire rate on 100Mbps mode forwarding and filtering 14 880 packets sec full wire rate on 10Mbps mode forwarding and filtering Self learning capability for up to 8K MAC addresses e 512KB buffer memory e Internal universal power supply Mountable in a standard 19 inch equipment rack 4 Product Overview Follow the steps outlined in this section to install and start using your Lancast CenturySwitch Unpack the Lancast CenturySwitch Check that the following components have been included e 8 Port CenturySwitch 3508 11 Rac
15. working properly check all wiring between it and the malfunctioning workstation Be sure that the transmit TX and receive RX cables are not crossed The transmit cable from the worksta tion should connect to the receive connector of the switch and the transmit cable from the switch should connect to the receive connector of the workstation e Use a continuity checker to ensure that wires do not have any breaks By shorting together the two wires at the end of a pair you can use the continuity checker at the other end Also check that there are no shorts between wires Workstation Problems Most non cabling problems result from improper configuration of the network interface card NIC and its corresponding driver Observe the following points e Like other add on cards in the workstation or server the NIC must have a unique memory address I O address and interrupt The settings on a particular card must not conflict with the settings on any other card in the same station Refer to the user s manuals of your NIC computer and network operating system to determine the proper configuration 12 User Guide The mode half duplex or full duplex and speed 10Mbps or 100Mbps of the NIC setting must match the mode and speed setting of the corresponding port of the switch For NWay Auto Negotiation setting both link partners will adjust to the highest allowable speed and mode operation Other Problems Other specific problems may be dia

Download Pdf Manuals

image

Related Search

Related Contents

  Manual Proprietario - Vivance  Hoover Vacuum Cleaner User's Manual  USER GUIDE  取扱説明書 Windows 2000編  service manual 125-250 XMOTION  

Copyright © All rights reserved.
Failed to retrieve file