Home

Lumex Syatems AQ2000 User's Manual

image

Contents

1. Contact your Graham Field dealer or visit Graham Field s Parts website www grahamfield com Info Specifications are subject to change without notice 14 AQ1000 INS LAB RevD13 WARRANTY GF Health Products Inc warrants the Lumex AQ1000 AQ2000 Alternating Pressure Pad and Pump System for defects in workmanship and materials for the terms listed below Pump one year Pad 90 days If a product is deemed to be under warranty GF Health Products Inc shall provide at its option 1 replacement of any defective part or product or 2 a credit of the original selling price made to GF Health Products Inc s initial customer The warranty does not include any labor charges incurred in replacement part s installation or any associated freight or shipping charges to GF Health Products Inc The warranties contained herein contain all the representations and warranties with respect to the subject matter of this document and supersede all prior negotiations agreements and understandings with respect thereto The recipient of this document hereby acknowledges and represents that it has not relied on any representation assertion guarantee warranty collateral contract or other assurance except those set out in this document AQ1000 INS LAB RevD13 15 GF Health Products Inc 2935 Northeast Parkway Atlanta Georgia 30360 tel 770 368 4700 fax 770 368 2386 GRAHAM FIELD www grahamfield com 2008 GF Health Pr
2. connectors before continuing A NOTICE Ensure that the air tubes are not kinked or tucked under the bubble pad or mattress Z WARNING Locate all cords so that they will not be stepped on tripped over or otherwise subjected to damage or stress WARNING Do not use a household extension cord if the electrical cord does not reach the power outlet Use of an improper extension cord could result in fire and electric shock If an extension cord must be used use a three conductor cord with ground properly wired in good electrical condition and keep it as short as possible WARNING This device which MUST be grounded is equipped with a cord that has a grounding wire with a grounding plug The plug must be plugged into an outlet that is properly installed and grounded A WARNING Ensure that the local power voltage is appropriate for the pump unit 7 Plug the power cord into a properly grounded electrical outlet 10 AQ1000 INS LAB RevD13 OPERATION 1 Turn the ON OFF switch to the ON position The pump will begin to deliver air into the bubble pad 2 Replace all sheets blankets and pillows on the bed Info if the pressure level seems low check for any leakage in the air tubes or bubble pad Replace any damaged tubes If necessary contact your Graham Field authorized distributor for repair or replacement AQ2000 ONLY PRESSURE ADJUSTMENT Adjust the pressure control dial for comfort Info For maximum effectivene
3. injury WARNING Do not leave this product unattended when plugged in Z WARNING Always use close supervision when this product is used by on or near children or those who require close supervision WARNING Use this product only as intended and described in this manual Do not use attachments or accessories not recommended by GF Health Products Inc 4 AQ1000 INS LAB RevD13 Z WARNING Never operate this product if a it has a damaged cord or plug b it is not working properly c it has been dropped or damaged d it has been dropped into water Return the product to your Graham Field authorized distributor Z WARNING Keep the cord away from heated surfaces Z WARNING Never block the air openings of this product or place it on a soft surface such as a bed or couch where the openings may be blocked Keep the air opening free of lint hair and other similar particles Z WARNING Never drop or insert any object into any opening or hose Z WARNING Connect this product only to a properly grounded power outlet Z WARNING Maximum patient weight capacity for this product is 275 Ib 125 kg EVENLY DISTRIBUTED Z WARNING Notice for California Customers California Proposition 65 WARNING This product contains a chemical known to the State of California to cause cancer and reproductive or developmental harm NOTICE A NOTICE The pump can be used only with the accompanying bubble pad Do not use it for any other
4. kawan keya eV E ER haw Ak KAWA 15 GF Health Products Inc is not responsible for typographical errors All illustrations specifications packaging and warranties contained in this document are based on the latest product information available at the time of printing The most current product information including the most current revision of this manual can be found online at www grahamfield com Graham Field and Lumex are registered trademarks of GF Health Products Inc 2 AQ1000 INS LAB RevD13 INTRODUCTION Use this manual for setup and operation of the Lumex AQ1000 AQ2000 Alternating Pressure Pad and Pump System Read all instructions before using the pad and pump system Save this manual for future reference INTENDED USE OF THIS DEVICE The intended use of the Alternating Pressure Pad and Pump System in either a homecare or long term care setting is the treatment of pressure ulcers while optimizing user comfort and pain management as prescribed by a physician Contraindication A WARNING DO NOT use this product in the presence of flammable anesthesia There is a possible fire hazard when this product is used with certain oxygen delivery equipment Use nasal cannula face mask or 1 2 length oxygen tent to deliver oxygen in the presence of this product DO NOT use a full length oxygen tent that extends past the top surface of the mattress with this product IMPORTANT SAFETY PRECAUTIONS The safety statements pres
5. purpose AQ1000 INS LAB RevD13 5 EQUIPMENT SYMBOLS ZN Attention Consult accompanying documents this manual BF symbol Indicates that this product is in accordance with the degree of protection against electric shock for type BF equipment Grounding terminal Class ll for UL only Disposal of Electrical amp Electronic Equipment WEEE Do not treat this product as household waste For more detailed information with regard to returning and recycling this product please consult your local city office household waste disposal service or Graham Field authorized distributor The system has been tested and successfully approved with the following standards e EN 60601 1 EN 60601 1 2 EN 55011 Class B EN 61000 3 2 EN 61000 3 3 IEC 801 2 IEC 801 3 IEC 801 4 IEC 801 5 6 AQ1000 INS LAB RevD13 PRODUCT DESCRIPTION BUBBLE PAD AND PUMP SYSTEM air tubes lt gt air tube connectors wire hangers l fuses a 7 220V only pump AQ2000 shown AQ1000 INS LAB RevD13 7 FRONT PANEL AQ1000 ON OFF TAT air tube connectors AQ1000 pump front panel AQ2000 ON OFF switch Tav J pressure control dial AQ2000 pump front panel Front panel pressure control dial AQ2000 only The pressure control dial controls the air pressure output To increase pressure turn the dial clockwise To decrease pressure turn the dial counter clockwis
6. LUMEX A01000 AQ2000 ALTERNATING PRESSURE BUBBLE PAD AND PUMP SYSTEM The latest version of this manual can be found online atwww grahamfield com AQ1000 INS LAB RevD13 CONTENTS INTRODUCTION nn nt kes kar a k na k kaka h k s ka ek k nc bna K k s ke Ru KAS b n RKRR GER 3 INTENDED USE OF THIS DEVICE in nrrnerresnnennnns 3 CONTRAINDICATION cccccscceseeeseeeeeseeeseeeeeesseeesseesseeeseeneneneeeeees 3 DANGER a s isi n ride ran n xa naka daya Ka xkna nak ku da kad kk a zad kude kada kk der Ha k da k K a xuna k dawa nek 4 WARNING oo 5 ixa xs sasi narana snknnnknnanana nnana na M na nan Sn AAa RE kana AESA SAIR A MA nA AR REKAR A 4 NOTICE s 4s sis a ank nena kini nenkkanannn kana kana kann nan AAR MARA AER A AA RA M R AE MA BE AA Bw K WR A WERA 5 EQUIPMENT SYMBOLS i kc iskasinnakakaakkacana anayasa kake dayka xakan nakaa 6 PRODUCT DESCRIPTION 4 lll lakkkaklkkkkkknkkakakanaka kaka ak KA WA KRAR AR 7 BUBBLE PAD AND PUMP SYSTEM rennes 7 PUMP 115 E 51x551 550an SE WEKE HAN SE Ka A Ra Weka WER D SE HESE WW EWE TASA i 7 FRONT PANEL 4 4 5 44x 444xa i izainana ckdna kak kana kak kana dti ER xa AR RA ARA Had R R R 8 AQ T isisi kilis s n ninalakisanas kik na kan k naA RAAARA AR AWIRA KERARA A ASEARA NANA IAA 8 AQZ20 0O i i i asi inanasyanan naya kana naya na ar Esana asana NSS NaRa
7. MAE MAR ERA AE again 8 INSTALLATION en krea ka KAR Kun kunek kurn k e bay k uk Kekan d ka e kaka kikan 9 UNPACKING k xsaiias iassiaskananaasnananananakaaanaaanananalak nansaakanakaaaka nak k 9 PUMP AND BUBBLE PAD INSTALLATION 9 OPERATION occ eves sir kedek a c ke cds vr k Ka dek ad ne eneke ev a ha ew ea O BUK KEK KRA AK 11 AQ2000 ONLY PRESSURE ADJUSTMENT ccessssseeessreeeseneseees 11 QUICK DISCONNEG Ui 1 5 542 2545a154 13405240 18201aan tienne ERE AR NEN ERA MIRA SERARAR 11 GPR F NC TIO N ii 14545511455443544552455544 et idee aaia cine ASA ee 11 MAINTENANCE 5 550 4i r w kan kun ka k kanan kk b ka dk kk R A kn e K KAKA RAKE NER RE REKAA 12 CLEANING onde berne ka k Sa n Wa k Saka da ku wak dl ah e wa e k Hw A9 KAD eu RAN 12 PUMP s sisiy kraak aa na nes u n alya d k dia E E ra a wane A a a 12 BUBBLE PAD s iks s s snensien nananananananan nnnaanna nanan ananananananananen 12 GENERAL MAINTENANCE 00 ccceceeeteeeeeseeeeeeeeseeeeseeeeeeseeeeneeeesenennes 12 FUSE REPLACEMENT 220V SYSTEM ONL 13 STORAGE 55h ccucesvicevsatie tenets KA Sah RN aaide i Xan DERA aeara WA RONA n RA RRA bak 13 SPECIFICATIONS i i sukan k n ina ka kanek kk kn ek k reka a kk k Ku a neke 2k RA ROK 14 WARRANTY Hi xirknneyak kan anaka kayan anan a kan keka k ku ah kw ka kwaaa k A
8. e 8 AQ1000 INS LAB RevD13 INSTALLATION UNPACKING 1 Before unpacking check for obvious damage to the carton or its contents If damage is evident please notify the carrier and your Graham Field authorized distributor 2 Remove all loose packing from the carton 3 Carefully remove all components from the carton 4 Inspect all components If damage is evident please notify the carrier and your Graham Field authorized distributor PUMP AND BUBBLE PAD INSTALLATION 1 Remove all sheets blankets and pillows from the bed 2 Place the bubble pad on the bed mattress with the tubing at the patient s feet lt n hanger foot end bubble pad La mattress Le pump AQ2000 shown installation 3 Fold open the wire hangers on the back of the pump as shown above 4 Use the hangers to hang the pump on the bed s foot end as shown above adjust the hangers to place the pump in the most upright position or place the pump on a flat surface easily accessible to the caregiver and or doctor A NOTICE Place the device in a position where the caregiver and or doctor can access it easily AQ1000 INS LAB RevD13 9 5 Connect one end of the air tubes to the bubble pad slide the ends of the air tubes over the connectors on the top of the foot end of the bubble pad 6 Connect the other end of the air tubes to the pump connectors ensure that the ends of the air tubes are firmly fitted over the bubble pad and pump
9. ented in this chapter refer to the basic safety information that should be observed by those using the Alternating Pressure Pad and Pump System There are additional safety statements in other chapters or sections which may be the same as or similar to the following or specific to the operations ZA DANGER Indicates an imminent hazard situation that if not avoided will result in death or serious injury ZA WARNING Indicates a potential hazard situation or unsafe practice that if not avoided could result in death or serious injury AQ1000 INS LAB RevD13 3 CAUTION Indicates a potential hazard or unsafe practice that if not avoided could result in minor or moderate personal injury A NOTICE Indicates a potential hazard or unsafe practice that if not avoided could result in product or property damage Info Provides application recommendations or other useful information to ensure that you get the most from your product DANGER To reduce the risk of electrocution Z DANGER Always unplug this product immediately after using Z DANGER Do not use this product while bathing ZA DANGER Do not place or store this product where it can fall or be pulled into a tub or sink ZA DANGER Do not place this product in or drop into water or other liquid ZA DANGER Do not reach for a product that has fallen into water Unplug it immediately WARNING To reduce the risk of burns electrocution fire or personal
10. oducts Inc
11. ss patient should sink into bubble pad to reduce pressure points Ensure that patient does not bottom out QUICK DISCONNECT Pull the power plug from the wall connector to disconnect the device quickly CPR FUNCTION If CPR must be performed on the patient while the bubble pad is in use to immediately deflate the bubble pad pull the air tubes off the bubble pad or pump connectors AQ1000 INS LAB RevD13 11 MAINTENANCE CLEANING Perform the following cleaning procedures before use and as necessary thereafter Pump Wipe the pump with a clean damp cloth and mild detergent and keep it away from dust Air dry A NOTICE Do not use phenolic products or corrosive or powdered cleansers to clean the pump A NOTICE Do not immerse or soak the pump Bubble pad Wipe the bubble pad with a clean damp cloth and mild detergent The bubble pad may also be cleaned using a 10 solution of sodium hypochlorite bleach diluted in water Air dry all parts thoroughly before use A NOTICE Do not use phenolic products to clean the bubble pad A NOTICE After cleaning air dry the bubble pad without direct exposure to sunlight GENERAL MAINTENANCE 1 Check main power cord for abrasion or excessive wear 2 Check bubble pad for signs of wear or damage Ensure air tubes are firmly secured to bubble pad and pump connectors 3 Check the air tubes for kinks or breaks For replacement please contact your Graham Field authorized dis
12. tributor 12 AQ1000 INS LAB RevD13 Fuse replacement 220V system onl tool needed small screwdriver 1 If you suspect a blown fuse disconnect the plug from the wall outlet immediately fuse D NR fuse location fuse cover 2 Use a small screwdriver to remove the cover of the fuse holder fuse locations are shown in picture above 3 Insert a new fuse of the correct rating T1A 250V 4 Replace the fuse holder cover Ensure that fuse holder cover is securely installed STORAGE 1 Fold the bubble pad loosely 2 Store bubble pad and pump in a dust free environment with no exposure to direct sunlight AQ1000 INS LAB RevD13 13 SPECIFICATIONS Model 01000 Standard _AQ2000 Deluxe Power Supply 220V T1A 250V Pressure 1 9 psi 13 10 kPa 1 0 2 0 psi 6 89 13 79 kPa 120V 4 5 LPM 120V 4 5 LPM 220V 5 0 LPM 220V 5 6 LPM Cycle Time 120V 5 min 220V 6 min Power Cord 10 ft 304 8 cm Length Pump Unit Size 8 5 x 4 25 x 3 62 in 9 75 x 5 12 x 3 88 in 21 59 x 10 80 x 9 19 cm 24 77 x 13 00 x 9 86 cm Pump Unit Weight 2 9 Ib 6 38 kg 3 5 Ib 7 7 kg Bubble pad Size 78 x 34x 2 5 in 76 x 34 x 2 5 in Inflated 198 12 x 86 36 x 6 35 cm 193 04 x 86 36 x 6 35 cm Weight Capacity 275 Ib 125 kg EVENLY DISTRIBUTED Bubble pad 14 GA anti bacterial flame retardant vinyl Material 2 each 5 ft 152 4 cm long clear PVC Replacement