Home
LSI Ultra320 User's Manual
Contents
1. 68 Pin VHDCI SCSI Device Cables 2 5 Version 2 1 Copyright 2002 2003 by LSI Logic Corporation All rights reserved 2 3 Connecting SCSI Devices This section explains how to connect internal and external SCSI devices to the Ultra320 SCSI host adapters 2 3 1 Connecting Internal SCSI Devices 2 6 This section provides step by step instructions for connecting internal SCSI devices The figures show the LSI22320 host adapter which has two internal connectors and two external connectors Other Ultra320 SCSI host adapter models have different numbers of connectors Refer to Section 2 2 1 Internal SCSI Cables page 2 4 for examples of internal cables If you only need to connect external devices skip to Section 2 3 3 Connecting External SCSI Devices page 2 9 Otherwise follow these steps Step 1 Plug the 68 pin connector on the end of the SCSI ribbon cable into the internal connector on the host adapter Figure 2 6 shows how to do this Figure 2 6 Connecting Internal SCSI Cable to Host Adapter Detailed Host Adapter Installation Version 2 1 Copyright 2002 2003 by LSI Logic Corporation All rights reserved Step 2 Plug the 68 pin connector on the other end of the internal SCSI ribbon cable into the SCSI connector on the internal SCSI device Figure 2 7 shows how to do this Figure 2 7 Connecting Multiple Internal SCSI Devices Step 3 If you have another internal SCSI device connect t
2. Vii Appendix A Glossary of Terms viii 3 2 3 3 3 1 2 LSI21320 Dual Channel Host Adapters Ola LS122320 Dual Channel Host Adapters Host Adapter Characteristics Technical Specifications Sa Electrical Characteristics 3 3 2 Thermal and Atmospheric Characteristics 3 3 3 Safety Characteristics Customer Feedback Contents Version 2 1 Copyright 2002 2003 by LSI Logic Corporation All rights reserved 3 4 3 6 3 8 3 8 3 9 3 9 3 10 Figures 21 2 2 2 3 2 4 2 5 2 6 2 7 2 8 2 9 2 10 3 1 3 2 3 3 3 4 Version 2 1 Hardware Connections for the Host Adapter Inserting the Host Adapter SCSI Cable 68 pin High Density with Terminator SCSI Cable 68 pin High Density without Terminator SCSI Cable 68 pin VHDCI Connecting Internal SCSI Cable to Host Adapter Connecting Multiple Internal SCSI Devices SCSI LED Connector Connecting One External SCSI Device Connecting Multiple External SCSI Devices LS120320 LSI20320 R and LSI21320L Host Adapters LSI20320H Host Adapter LS121320 or LS121320 R Drawing LS122320 and LSI22320 R Drawing Copyright 2002 2003 by LSI Logic Corporation All rights reserved 2 2 2 3 2 4 2 4 2 5 2 6 er 2 8 2 9 2 10 3 3 3 5 3 7 Version 2 1 Copyright 2002 2003 by LSI Logic Corporation All rights reserved Tables ql 2 1 2 2 3 1 3 2 3 3 Version 2 1 Ultra320 SCSI Controllers and Host Adapters SCSI ID Record for Dual Channel Adapter Host A
3. two external 68 pin very high density cable interconnect VHDCI connectors two internal 68 pin high density connectors e LVD SE termination e LSI Logic Integrated Mirroring IM technology for boot volume and operating system protection IM is for the LSI22320 R only e Fusion MPT architecture Ultra320 SCSI to PCI X Host Adapters 3 5 Version 2 1 Copyright 2002 2003 by LSI Logic Corporation All rights reserved Details of the LSI22320 and LSI22320 R host adapters are e J1 PCI and PCI X 64 bit universal type board edge connector e J2 and J3 68 pin very high density cable interconnect right angle external connectors e J4 and J6 68 pin high density right angle internal connectors e J5 4 pin low density unshrouded right angle LED connector e Subsystem Vendor ID 0x1000 e Subsystem ID 0x1010 During system initialization the system loads the ID numbers into the Subsystem Vendor ID and Subsystem ID registers of the embedded SCSI controller Figure 3 4 illustrates the LSI22320 or LSI22320 R host adapter Figure 3 4 LSI22320 and LSI22320 R Drawing Channe Itra8320 SCSI LVD SE Channe ra320 SCSI LVD SE 3 J3 28 Channel B e Ultra320 SCSI LVD SE s J2 se Channel A 3 Ultra320 SCSI LVD SE LSI53C1030 J1 PCI and PCI X UOMO ooon ononon 3 6 Ultra320 SCSI Host Adapter Characteristics Version 2 1 Copyright 2002 2003 by LSI Logic Corporation All rights reserved 3 2 Host Adapte
4. by LSI Logic Corporation All rights reserved Table 3 3 Host Adapter Maximum Power Requirements PCI PCI X 5 0 V PCI PCI X 3 3 V PCI PRSNT1 PRSNT2 Power Over the Operating Range LS120320 1 5A 2 0A 15 W 0 C to 55 C LS120320 R LS120320 L LS120320 H LS121320 0 C to 55 C LS121320 R LS122320 0 C to 55 C LS122320 R 3 3 2 Thermal and Atmospheric Characteristics The thermal and atmospheric characteristics for all Ultra320 SCSI host adapters are e temperature range 0 C to 55 C dry bulb e relative humidity range 5 to 90 noncondensing e maximum dew point temperature 32 C e airflow must be sufficient to keep the LSI53C1020 and LSI53C 1030 heat sink temperature below 80 C The following parameters define the storage and transit environment for the Ultra320 SCSI host adapters e temperature range 40 C to 105 C dry bulb e relative humidity range 5 to 90 noncondensing 3 3 3 Safety Characteristics 3 8 All Ultra320 SCSI host adapters meet or exceed the requirements of UL flammability rating 94 VO Each bare board is also marked with the supplier s name or trademark type and UL flammability rating Because these boards are installed in a PCI bus slot all voltages are below the SELV 42 4 V limit Ultra320 SCSI Host Adapter Characteristics Version 2 1 Copyright 2002 2003 by LSI Logic Corporation All rights reserve
5. e Fusion MPT architecture Details of the LSI20320 LSI20320 R and LSI20320L host adapters are e J5 PCI and PCI X 64 bit universal type board edge connector e J1 68 pin very high density cable interconnect shielded right angle external connector e J3 68 pin high density right angle internal connector e HDR2 4 pin low density un shrouded right angle LED connector e Subsystem Vendor ID 0x1000 e Subsystem ID 0x1060 During system initialization the system loads the ID numbers into the Subsystem Vendor ID and Subsystem ID registers of the embedded SCSI controller Ultra320 SCSI Host Adapter Characteristics Version 2 1 Copyright 2002 2003 by LSI Logic Corporation All rights reserved Figure 3 1 illustrates the LSI20320 LSI20320 R or LSI20320L host adapter The LSI20320L adapter uses a PCI low profile bracket Figure 3 2 illustrates the LSI20320H host adapter Figure 3 1 LSI20320 LSI20320 R and LSI21320L Host Adapters o HDR2 Connector for Channel A o0o000000000000000 oooo0o0000000000000 oo0o00000000000000 nonooooo0o0o0000000000 J3 Channel A Internal SCSI Connector LSI53C1020 00000000000000000 90000000000000000 oo000000000000000 00000000000000000 Ji Channel A J5 PCI and PCI X 64 Bit Edge Connector External VHDCI IY OO On O MOA O Figure 3 2 LSI20320H Host Adapter 20000000000000000 ooo000000000000000 Dooo0o000000000000 J6 for Channel A O J4 Channel A Ultra320
6. the last external SCSI device as shown in Figure 2 10 See Section 2 4 Terminating the SCSI Bus page 2 11 for more information about SCSI bus termination Detailed Host Adapter Installation Version 2 1 Copyright 2002 2003 by LSI Logic Corporation All rights reserved 2 4 Terminating the SCSI Bus The SCSI bus contains all the devices that you connect with SCSI cables When you connect the first and last physical SCSI devices on the ends of the SCSI bus you must have termination active You must remove or disable termination on all other SCSI devices on the same bus If you connected only internal SCSI devices on a bus the host adapter automatically terminates itself If you connected only external SCSI devices on a bus the host adapter also terminates automatically Automatic termination occurs because the host adapter connection is at the end of the SCSI bus If you connect both internal and external SCSI devices on a bus the host adapter automatically disables its termination This occurs because the host adapter is in the middle of the SCSI bus 2 4 1 LSI20320 Host Adapter Termination The LS1I20320 LSI20320H LSI20320L and LSI20320 R host adapters provide active termination with an automatic means of enabling and disabling the termination When you connect SCSI devices to both the internal and external connectors host adapter termination is automatically disabled 2 4 2 LSI21320 Host Adapter Termination The LSI21
7. 02 2003 by LSI Logic Corporation All rights reserved 2 3 3 Connecting External SCSI Devices This section provides step by step instructions for connecting external SCSI devices Refer to Section 2 2 2 External SCSI Cable page 2 5 for examples of external cables Step 1 Plug the 68 pin VHDCI connector on one end of a shielded external high density cable into the host adapter s external SCSI connector This connector is exposed on the back panel of your computer Step 2 Plug the 68 pin VHDCI connector on the other end of the shielded external SCSI cable into the SCSI connector on the first external SCSI device Figure 2 9 shows how to connect a single external SCSI device If you have the correct cable it will match the external connector Figure 2 9 Connecting One External SCSI Device Connecting SCSI Devices 2 9 Version 2 1 Copyright 2002 2003 by LSI Logic Corporation All rights reserved 2 10 Step 3 Connect any additional SCSI devices to one another with shielded external SCSI cables You need a separate SCSI cable for each additional device Figure 2 10 shows how to connect multiple external SCSI devices Figure 2 10 Connecting Multiple External SCSI Devices Enable termination on the device at the end of the bus Disable termination on all devices not at the end of the bus a Host Adapter Automatically Terminated Step 4 Be sure that termination is enabled on
8. 2 SCSI Ultra160 SCSI Ultra320 SCSI VHDCI The domain validation method developed and used by LSI Logic SureLINK provides three levels of integrity checking Basic level 1 Enhanced level 2 and Margined level 3 A standard for SCSI data transfers It allows a transfer rate of up to 20 Mbytes s over an 8 bit SCSI bus and up to 40 Mbytes s over a 16 bit SCSI bus A standard for SCSI data transfers It allows a transfer rate of up to 40 Mbytes s over an 8 bit SCSI bus and up to 80 Mbytes s over a 16 bit SCSI bus A standard for SCSI data transfers It allows a transfer rate of up to 160 Mbytes s over a 16 bit SCSI bus A standard for SCSI data transfers It allows a transfer rate of up to 320 Mbytes s over a 16 bit SCSI bus Very High Density Cable Interconnect VHDCI cables are used to connect external SCSI devices to the host adapter Glossary of Terms A 3 Version 2 1 Copyright 2002 2003 by LSI Logic Corporation All rights reserved A 4 Glossary of Terms Version 2 1 Copyright 2002 2003 by LSI Logic Corporation All rights reserved Customer Feedback We would appreciate your feedback on this document Please copy the following page add your comments and fax it to us at the number shown If appropriate please also fax copies of any marked up pages from this document Important Please include your name phone number fax number and company address so that we may contact you directly for clarific
9. 320 R host adapter provides active termination with an automatic means of enabling and disabling the termination When you connect SCSI devices to the internal and external connectors on Channel A termination for Channel A is automatically disabled Channel B has only one SCSI connector Channel B termination is always enabled 2 4 3 LSI22320 Host Adapter Termination The LS1I22320 R host adapter provides active termination with an automatic means of enabling and disabling the termination When you connect SCSI devices to both the internal and external connectors on a given channel termination for that channel is automatically disabled Terminating the SCSI Bus 2 11 Version 2 1 Copyright 2002 2003 by LSI Logic Corporation All rights reserved 2 5 Setting SCSI IDs SCSI IDs identify each SCSI device on the SCSI bus Each SCSI ID on a given bus must be unique The IDs are 0 through 15 for a 16 bit bus The preset host adapter ID setting is 7 which gives the highest priority to the host adapter If you plan to boot your computer from a SCSI hard disk drive you must assign SCSI ID 0 to the drive Normally you do not change the host adapter SCSI ID setting from its default value Typically you set the SCSI ID of the SCSI device with jumpers or with a switch on the device You must not duplicate SCSI IDs on a SCSI bus LSI Logic recommends that you record the SCSI IDs of all SCSI devices Table 2 1 provides a place to keep this re
10. D 0x1000 Subsystem ID 0x1040 During system initialization the system loads the ID numbers into the Subsystem Vendor ID and Subsystem ID registers of the embedded SCSI controller Figure 3 3 illustrates the LSI21320 or LSI2120 R host adapter board 3 4 Ultra320 SCSI Host Adapter Characteristics Version 2 1 Copyright 2002 2003 by LSI Logic Corporation All rights reserved Figure 3 3 O J2 o 0808 OnO 080 DO olo 020 ogo 020 olo olo olo 020 o 0 Ouo 080 DO olo 020 ogo 020 o 0 O O 080 oxo ozo ozo 020 DO olo 020 2926 o n alo LSI21320 or LSI21320 R Drawing 000000000 Ut ooo00 0000000000000 oo 0000 o90000000000000000 o00000000000000000 oooo0oo0000000000000 900000000000000000 J6 for noco0c0000000000000 goo0o00000000000000 J4 Channel A Ultra320 SCSI LVD SE Ultra320 SCSI LVD SE Channel A Ultra320 SCSI LVD SE Channels J3 A and B Channel B LSI53C1030 J1 PCI and PCI X i OOOO O CCAM 3 1 3 LSI22320 Dual Channel Host Adapters The LSI Logic LS122320 and LSI22320 R are dual channel Ultra320 SCSI to PCI X host adapters that provide two Ultra320 SCSI channels The SCSI Channel A interface is made through connectors J2 and J6 The SCSI Channel B interface is made through connectors J3 and J4 See Figure 3 4 for details Features of the LSI22320 and LSI22320 R host adapters are e two independent Ultra320 SCSI channels e four SCSI connectors
11. MPT Message Passing Technology architecture consists of several main elements Fusion MPT firmware the Fibre Channel and SCSI hardware and the operating system level drivers that support these architectures Fusion MPT architecture offers a single binary operating system driver that supports both Fibre Channel and SCSI devices Ultra320 SCSI to PCI X Host Adapters User s Guide A 1 Version 2 1 Copyright 2002 2003 by LSI Logic Corporation All rights reserved Host Host Adapter Internal SCSI Device PCI and PCI X Peripheral Device SCSI Bus SCSI Device SCSI ID Single Ended SCSI A 2 The computer system in which a SCSI host adapter is installed It uses the SCSI host adapter to transfer information to and from devices attached to the SCSI bus A circuit board or integrated circuit that provides a device connection to the host A SCSI device installed inside the computer cabinet These devices are connected to one another with an unshielded ribbon cable Peripheral Component Interconnect A high performance local bus specification that allows connection of devices directly to computer memory The PCI Local Bus allows transparent upgrades from a 32 bit data path at 33 MHz to a 64 bit data path at 33 MHz from a 32 bit data path at 66 MHz to a 64 bit data path at 66 MHz and from a 32 bit data path at 133 MHz to a 64 bit data path at 133 MHz 1064 Mbytes s peak A piece of hardware such as a disk drive pri
12. SCSI LVD SE J2 Channel A Ultra320 SCSI LVD SE LSI53C1020 o 0808 ozo O50 ozo ogo 050 050 ozo 05 ozo 059 020 ozo ozo ogo 0o50 ozo ozo ogo O70 ozo ozo ogo 0o50 05 050 050 lobe ogo ozo 0990 oo J1 PCI and PCI X TOC an nan ANN NO AoAOOo lo Ultra320 SCSI to PCI X Host Adapters 3 3 Version 2 1 Copyright 2002 2003 by LSI Logic Corporation All rights reserved 3 1 2 LSI21320 Dual Channel Host Adapters The LSI Logic LSI21320 and LSI21320 R are dual channel Ultra320 SCSI to PCI X host adapters that provide two Ultra320 SCSI channels The SCSI Channel A interface is made through connectors J2 and J4 The SCSI Channel B interface is made through connector J3 See Figure 3 3 for details Features of the LSI21320 host adapters are two independent Ultra320 SCSI channels three SCSI connectors one external 68 pin high density connector two internal 68 pin high density connectors LVD SE termination LSI Logic Integrated Mirroring IM technology for boot volume and operating system protection IM is for the LSI21320 R only Fusion MPT architecture Details of the LSI21320 and LSI21320 R host adapters are J1 PCI and PCI X 64 bit universal type board edge connector J2 68 pin high density cable right angle external connector J3 and J4 68 pin high density right angle internal connectors J6 4 pin low density unshrouded right angle LED connector Subsystem Vendor I
13. SI Standard 6 6 x 3 25 inches 167 6 x 82 6 mm LS121320 R Dual Channel Ultra320 SCSI Standard 6 6 x 3 25 inches 167 6 x 82 6 mm LS122320 Dual Channel Ultra320 SCSI Standard 6 6 x 4 0 inches 167 6 x 106 7 mm LS122320 R Dual Channel Ultra320 SCSI Standard 6 6 x 4 0 inches 167 6 x 106 7 mm Ultra320 SCSI to PCI X Host Adapters User s Guide 3 1 Version 2 1 Copyright 2002 2003 by LSI Logic Corporation All rights reserved 3 1 1 LSI20320 Single Channel Host Adapters 3 2 The LS120320 LSI20320 R LSI20320L and LSI20320H are single channel Ultra320 SCSI to PCI X host adapters that provide one Ultra320 SCSI channel The SCSI Channel A interface for the LSI20320 LSI20320 R and LSI20320L is made through connectors J1 and J3 See Figure 3 1 for details The SCSI Channel A interface for the LSI20320H is made through connectors J2 and J4 See Figure 3 2 for details Features of the LSI20320 series of host adapters are e single Ultra320 SCSI channel e two SCSI connectors one external 68 pin very high density cable interconnect VHDCI connection for LSI20320 LSI20320 R and LSI20320L one external 68 pin high density connector for LSI20320H one internal 68 pin high density connector for all boards e PCI low profile bracket LSI20320L only e LVD SE termination e LSI Logic Integrated Mirroring IM technology for boot volume and operating system protection IM is for the LSI20320 R only
14. SI bus connections secure e Is the SCSI bus terminated correctly e Have the SCSI IDs been set and recorded for each device Replace the cabinet cover on your computer Plug in all power cords and turn on power to all devices and your computer Wait for your computer to start up The host adapter installation is complete Quick Host Adapter Installation 1 3 Version 2 1 Copyright 2002 2003 by LSI Logic Corporation All rights reserved 1 3 Quick Windows Driver Installation To load the SYMMPI SYS miniport driver during a new Windows NT Windows 2000 Windows XP or Windows NET system installation you can boot directly from the Microsoft installation CD ROM The Windows drivers are not interchangeable however the instructions are very similar To install a new Windows operating system and its appropriate device driver follow these steps Step 1 Step 2 Step 3 Have the Microsoft Windows driver diskette available to insert into drive A when prompted Boot the computer from the Microsoft Windows CD ROM Press F6 when the words Setup is inspecting your computer s hardware configuration appear or when Windows prompts you for nonsupported drivers Important You must press F6 for the new driver to be recognized Oth erwise the system does not recognize the devices con trolled by the driver during the Windows setup Step 4 Follow the instructions until a screen displaying the words Setup could
15. USER S GUIDE Ultra320 SCSI to PCI X Host Adapters July 2003 Version 2 1 LSIDKee DB15 000192 01 Fe CE Electromagnetic Compatibility Notices This device complies with Part 15 of the FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 This device must accept any interference received including interference that may cause undesired operation This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and the receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an exper
16. ation or additional information Thank you for your help in improving the quality of our documents Version 2 1 Copyright 2002 2003 by LSI Logic Corporation All rights reserved Reader s Comments Fax your comments to LSI Logic Corporation Technical Publications M S AF 198 Fax 408 433 4333 Please tell us how you rate this document Ultra320 SCSI to PCI X Host Adapters User s Guide Place a check mark in the appropriate blank for each category Excellent Good Average Fair Poor Completeness of information Clarity of information Ease of finding information Technical content Usefulness of examples and illustrations Overall manual What could we do to improve this document If you found errors in this document please specify the error and page number If appropriate please fax a marked up copy of the page s Please complete the information below so that we may contact you directly for clarification or additional information Name Date Telephone Fax Title Department Mail Stop Company Name Street City State Zip Version 2 1 Copyright 2002 2003 by LSI Logic Corporation All rights reserved You can find a current list of our U S distributors international distributors and sales offices and design resource centers on our web site at http www lsilogic com contacts index html
17. cord Table 2 1 SCSI ID Record for Dual Channel Adapter SCSI ID SCSI Device Channel A SCSI Device Channel B Ultra320 SCSI to PCI X host Ultra320 SCSI to PCI X host adapter adapter 2 12 Detailed Host Adapter Installation Version 2 1 Copyright 2002 2003 by LSI Logic Corporation All rights reserved 2 6 Completing the Installation Before replacing the cover on your computer complete the checklist as shown in Table 2 2 Table 2 2 Host Adapter Installation Check List Verify Installation Procedures Done Host adapter connection in PCI X bus slot is secure level Internal SCSI bus connections are secure pin 1 continuity External SCSI bus connections are secure Proper SCSI bus termination established Unique SCSI IDs set and recorded for each device After you verify all items on the checklist follow these steps Step 1 Replace the cabinet cover on your computer Step 2 Plug in all power cords and turn on power to all devices and your computer Step 3 Wait for your computer to boot up Note To change default configurations of the Ultra320 SCSI host adapters refer to the Fusion MPT Device Management System User s Guide Completing the Installation 2 13 Version 2 1 Copyright 2002 2003 by LSI Logic Corporation All rights reserved 2 14 Detailed Host Adapter Installation Version 2 1 Copyright 2002 2003 by LSI Logic Corpo
18. d Active Termination BIOS Configuration Device Driver Domain Validation EEPROM External SCSI Device Fusion MPT Architecture Appendix A Glossary of Terms The electrical connection required at each end of the SCSI bus composed of active voltage regulation and a set of termination resistors Ultra SCSI Ultra2 SCSI Ultra160 SCSI and Ultra320 SCSI require active termination Basic Input Output System Software that provides basic read write capability Usually kept as firmware ROM based The system BIOS on the mainboard of a computer is used to boot and control the system The SCSI BIOS on the host adapter acts as an extension of the system BIOS Refers to the way a computer is set up the combined hardware components computer monitor keyboard and peripheral devices that make up a computer system or the software settings that allow the hardware components to communicate with each other A program that allows a microprocessor through the operating system to direct the operation of a peripheral device such as a disk drive A software procedure in which a host queries a device to determine its ability to communicate at the negotiated data rate Electronically Erasable Programmable Read Only Memory A memory chip typically used to store configuration information A SCSI device installed outside the computer cabinet These devices are connected together using specific types of shielded cables Fusion
19. dapter Installation Check List Ultra320 SCSI 64 bit 133 MHz PCI X Host Adapters Host Adapter Characteristics Maximum Power Requirements Copyright 2002 2003 by LSI Logic Corporation All rights reserved 1 1 a2 218 3 1 3 8 3 9 xi xii Version 2 1 Copyright 2002 2003 by LSI Logic Corporation All rights reserved Chapter 1 Quick Installation Procedures This chapter contains general information about Ultra320 SCSI controllers and host adapters It provides quick host adapter installation instructions and SCSI bus setup for experienced computer users It also provides quick installation instructions for Windows device drivers This chapter includes these topics e Section 1 1 General Description page 1 1 e Section 1 2 Quick Host Adapter Installation page 1 2 e Section 1 3 Quick Windows Driver Installation page 1 4 1 1 General Description LSI Logic provides high performance cost effective Ultra320 SCSI controllers and host adapters Table 1 1 shows the LSI Logic controllers and their associated host adapters that support Ultra320 SCSI For specific information about the Ultra320 SCSI controllers refer to the related publications section in the Preface Table 1 1 Ultra320 SCSI Controllers and Host Adapters Conirollers Host Adapiers LSI53C1020 LS120320 LSI20320H LSI20320L LSI20320 R LSI53C1030 LS121320 LS121320 R LS122320 LSI22320 R Installing any of these adapters in you
20. he internal SCSI ribbon cable to it Figure 2 7 shows how to do this You can connect other devices if the cable has more connectors The Ultra320 SCSI host adapters support up to 15 SCSI devices connected to each SCSI channel Step 4 Be sure that termination is enabled at the end of the cable that is farthest away from the SCSI host adapter See Section 2 4 Connecting SCSI Devices 2 7 Version 2 1 Copyright 2002 2003 by LSI Logic Corporation All rights reserved Terminating the SCSI Bus page 2 11 for more information about SCSI bus termination 2 3 2 Connecting the LED Cable 2 8 Most computer cabinets have a front panel LED When properly connected the front panel LED lights when there is activity on the SCSI bus Connect the LED cable to connector J5 on the host adapter as shown in Figure 2 8 Connector J5 is not keyed Figure 2 8 SCSI LED Connector LED Connector J5 Left two pins are for Channel A Right two pins are for Channel B The orientation of the LED cable does not matter as long as all four pins are connected If the LED does not light during SCSI bus activity from this host adapter you may have to rotate the LED cable connector 180 on J5 If your LED cable has only two wires place the connector on one end or the other of J5 If the LED does not light when there is SCSI activity move the connector to the other half of J5 Detailed Host Adapter Installation Version 2 1 Copyright 20
21. his document assumes that you have some familiarity with SCSI protocol and related support devices This document benefits people installing and using the various Ultra320 SCSI to PCI X host adapters This document has the following chapters and appendixes e Chapter 1 Quick Installation Procedures provides quick instructions for installing your Ultra320 SCSI host adapter and Windows device drivers e Chapter 2 Detailed Host Adapter Installation provides detailed instructions for installing your Ultra320 SCSI host adapter e Chapter 3 Ultra320 SCSI Host Adapter Characteristics illustrates the various LSI Logic Ultra320 SCSI host adapters and provides PCI and SCSI interface information e Appendix A Glossary of Terms provides definitions of terms used in this book Ultra320 SCSI to PCI X Host Adapters User s Guide v Version 2 1 Copyright 2002 2003 by LSI Logic Corporation All rights reserved Related Publications Revision Record Version 9 2001 LS1I53C1020 PCI to Ultra320 SCSI Controller Technical Manual LSI Logic Corporation Document number DB14 000176 04 LSI53C 1030 PCI to Dual Channel Ultra320 SCSI Multifunction Controller Technical Manual LSI Logic Corporation Document number DB14 000156 03 Fusion MPT Device Management User s Guide LSI Logic Corporation Document number DB15 000186 01 Remarks This release provides information about the LSI22320 R LS121320 and LS120320 Ultra320 SCSI to PCI H
22. ienced radio TV technician for help Shielded cables for SCSI connection external to the cabinet are used in the compliance testing of this Product LSI Logic is not responsible for any radio or television interference caused by unauthorized modification of this equipment or the substitution or attachment of connecting cables and equipment other than those specified by LSI Logic The correction of interferences caused by such unauthorized modification substitution or attachment will be the responsibility of the user The LSI Logic Ultra320 SCSI to PCI Host Adapters LSI20320 LSI20320H LSI20320L LSI20320 R LSI21320 LS121320 R LSI22320 LSI22320 R are tested to comply with FCC standards for home or office use This Class B digital apparatus meets all requirements of the Canadian Interference Causing Equipment Regulations Cet appareil num rique de la classe B respecte toutes les exigences du R glement sur le mat riel brouilleur du Canada CORB PRUBRESRRMSAEMM BMA VCCI ORE KED VTA BEM EE CT CORB REWRCHATSCL SAWCUTIETM CORBMNIVAPTLEY a YRIARICRLT GASNSe SBE SRC TCEMHVET RRRA TIEL MOREL TRAY This is a Class B product based on the standard of the Voluntary Control Council for Interference from Information Technology Equipment VCCI If this is used near a radio or television receiver in a domestic environment it may cause radio interference Install and use the equipment according to the instruction manual LSI Logic A
23. llowing illustrations show the LS122320 R Dual Channel Ultra320 SCSI host adapter However these illustrations apply to all host adapters For more information about all the Ultra320 SCSI host adapters see Chapter 3 Ultra320 SCSI Host Adapter Characteristics 2 1 1 Selecting a PCI Slot Step 1 Turn off and unplug your computer Warning Be sure to disconnect the computer s power before you remove the cover and install the Ultra320 SCSI host adapter Step 2 Open your computer cabinet by removing its cover Step 3 Be sure to touch a grounded metal surface to discharge static electricity before removing the host adapter from its package Ultra320 SCSI to PCI X Host Adapters User s Guide 2 1 Version 2 1 Copyright 2002 2003 by LSI Logic Corporation All rights reserved Caution You must touch a grounded metal surface before handling the host adapter because static charges on your body can damage electronic components Handle plug in boards by the edge do not touch board components or gold connec tor contacts LSI Logic recommends that you use a static ground strap Step 4 Remove your Ultra320 SCSI host adapter from its packaging and verify that it is not damaged Figure 2 1 shows the LSI22320 host adapter The LSI20320 and LS121320 Ultra8320 SCSI host adapters are different in design and size Refer to Chapter 3 Ultra320 SCSI Host Adapter Characteristics for more details Figure 2 1 Hardware Connections fo
24. not determine the type of one or more mass storage device appears Step 5 Choose S to Specify Additional Devices Step 6 Follow the prompts and insert the Windows driver diskette when prompted Step 7 Follow the Microsoft Windows installation procedure to complete the installation Microsoft provides documentation with their installation CD ROM Step 8 If you are installing Windows NT 4 0 also install the Service Packs 5 or higher after Windows NT 4 0 has been installed Note Refer to the Fusion MPT Device Management User s Guide for detailed configuration and installation instructions for all firmware and drivers 1 4 Quick Installation Procedures Version 2 1 Copyright 2002 2003 by LSI Logic Corporation All rights reserved Chapter 2 Detailed Host Adapter Installation This chapter provides detailed instructions on how to install the LSI Logic Ultra320 SCSI to PCI X host adapters and includes these topics e Section 2 1 Installing your Ultra320 SCSI Host Adapter page 2 1 e Section 2 2 SCSI Device Cables page 2 4 e Section 2 3 Connecting SCSI Devices page 2 6 e Section 2 4 Terminating the SCSI Bus page 2 11 e Section 2 5 Setting SCSI IDs page 2 12 e Section 2 6 Completing the Installation page 2 13 2 1 Installing your Ultra320 SCSI Host Adapter This section provides detailed instructions for installing your host adapter and connecting your SCSI devices to it The fo
25. nter or CD ROM used with a computer and under the computer s control SCSI peripheral devices are controlled through a SCSI host adapter A host adapter and one or more SCSI devices connected by cables in a linear configuration The host adapter may exist anywhere on the bus allowing connection of both internal and external SCSI devices A system may have more than one SCSI bus by using a multichannel host adapter or by using multiple host adapters Any device that conforms to the SCSI standard and is attached to the SCSI bus by a SCSI cable This includes SCSI host adapters SCSI disk drives SCSI CD ROMS drives and so on An identifier that addresses specific devices on the SCSI bus and determines device selection when multiple devices contend for ownership of the SCSI bus Wide SCSI buses support SCSI IDs 0 through 15 and narrow SCSI buses support SCSI IDs 0 through 7 A device gains ownership of the bus according to the priority of its SCSI ID The order of priority from highest to lowest is 7 6 5 4 3 2 1 0 15 14 13 12 11 10 9 The host adapter is usually set to the highest priority SCSI ID which is SCSI ID 7 A hardware specification for connecting SCSI devices It references each SCSI signal to a common ground In contrast differential SCSI uses a separate ground for each signal Glossary of Terms Version 2 1 Copyright 2002 2003 by LSI Logic Corporation All rights reserved SureLINK Ultra SCSI Ultra
26. ost Adapters 5 2002 Final version vi 7 2003 Corrected glossary entries for Ultra160 and Ultra320 Other minor editing also In Section 3 3 2 corrected storage temp range to 40 C to 105 C Preface Version 2 1 Copyright 2002 2003 by LSI Logic Corporation All rights reserved Contents Chapier 1 Quick Installation Procedures 11 1 2 1 3 Chapter 2 General Description Quick Host Adapter Installation Quick Windows Driver Installation Detailed Host Adapter Installation 2 1 2 2 2 3 2 4 2 5 2 6 Chapter 3 Installing your Ultra320 SCSI Host Adapter 2 1 1 Selecting a PCI Slot 2 1 2 Inserting the Host Adapter SCSI Device Cables 2 2 1 Internal SCSI Cables 2 2 2 External SCSI Cable Connecting SCSI Devices 2 351 Connecting Internal SCSI Devices 2 3 2 Connecting the LED Cable 23 3 Connecting External SCSI Devices Terminating the SCSI Bus 2 4 1 LSI20320 Host Adapter Termination 2 4 2 LSI21320 Host Adapter Termination 2 4 3 LSI22320 Host Adapter Termination Setting SCSI IDs Completing the Installation Ultra320 SCSI Host Adapter Characteristics 3 1 Ultra320 SCSI to PCI X Host Adapters lt P LS120320 Single Channel Host Adapters Ultra320 SCSI to PCI X Host Adapters User s Guide Version 2 1 Copyright 2002 2003 by LSI Logic Corporation All rights reserved 1 1 12 1 4 2l ol 2 3 2 4 25 2 6 2 6 2 8 2 9 211 2 11 21 2 11 2 12 2 13 3 1 3 2
27. r Characteristics Table 3 2 shows the general characteristics for all Ultra320 SCSI PCI Host Adapters Table 3 2 Host Adapter Characteristics Serial LVD SE Ultra320 SCSI SCSI SCSI Si Signaling Data Transfers Features Termination 16 bit SE Up to 320 Mbytes s as well as Plug and Play TERMPWR with or LVD Fast Ultra Ultra2 and Scatter Gather autoresetting interfaces Ultra160 speeds Synchronous Activity LED circuit breaker offsets up to 62 For boot code and firmware gt For BIOS configuration storage Each Ultra320 SCSI adapter offers SureLINK Domain Validation technology to ensure data integrity by intelligently validating the compatibility of the SCSI domain These adapters also utilize Fusion MPT architecture that allows for thinner drivers and better performance 3 3 Technical Specifications The design and implementation of the Ultra320 SCSI host adapters minimize electromagnetic emissions susceptibility to radio frequency energy and the effects of electrostatic discharge The adapter carries the CE mark C Tick mark FCC Self Certification logo Canadian Compliance Statement Korean MIC Taiwan BSMI Japan VCCI and meets the requirements of CISPR Class B 3 3 1 Electrical Characteristics Table 3 3 lists the maximum power requirements for standard Ultra320 SCSI to PCI X host adapters including SCSI TERMPWR under normal operation Host Adapter Characteristics 3 7 Version 2 1 Copyright 2002 2003
28. r PCI or PCI X system allows you to connect up to 15 SCSI devices per channel over a SCSI bus You can use the Ultra320 SCSI host adapters in PCI X computer systems with a standard bracket type Ultra320 SCSI to PCI X Host Adapters User s Guide 1 1 Version 2 1 Copyright 2002 2003 by LSI Logic Corporation All rights reserved To achieve Ultra320 SCSI performance you must connect only Low Voltage Differential LVD devices to the host adapter If you connect single ended SE devices and LVD devices the entire bus will drop to the lower SE speed limiting bus performance to Ultra SCSI The Ultra320 SCSI host adapters support all major operating systems such as Windows NT 4 0 2000 NET and XP Linux NetWare UnixWare SCO OpenServer 5 X OS 2 and Solaris Other software support includes SureLINK Domain Validation on Windows systems Domain Validation ensures data integrity by intelligently testing the network before completing negotiation The Ultra320 SCSI host adapters utilize Fusion MPT architecture for all major operating systems which allows for thinner drivers and better performance To obtain a device driver that supports your operating system contact the LSI Logic technical support team at 719 533 7230 or visit our website at http www lsilogic com 1 2 Quick Host Adapter Installation 1 2 Use these quick installation steps if you have installed computer add in boards before and connected devices to them If
29. r the Host Adapter Channel A 68 Pin Internal High Density SCSI Interface Channel A amp B Channel B J6 Connector Busy LED 68 Pin Internal 3 Connector High Density J5 SCSI Interface J4 Connector Channel B 68 Pin External VHDCI SCSI J3 Connector Channel A 68 Pin External VHDCI SCSI J2 Connector J1 Connector PCI X Bus to Mainboard Step 5 Find an unused PCI X or PCI slot Note You can insert a 64 bit host adapter into a 32 bit slot if no 64 bit slots are available However if you do this the data transmission rate is limited to standard PCI speed 2 2 Detailed Host Adapter Installation Version 2 1 Copyright 2002 2003 by LSI Logic Corporation All rights reserved 2 1 2 Inserting the Host Adapter Perform the following steps to install your Ultra320 SCSI host adapter in the PC mainboard Step 1 Remove the blank bracket panel on the back of the computer that is aligned with the PCI X slot you have selected Save the bracket screw Step 2 Carefully insert the edge connector J1 of the host adapter into the PCI X slot as shown in Figure 2 2 Figure 2 2 Inserting the Host Adapter i Bracket Screw D lt u Slots Step 3 Make sure the edge connector is properly aligned before pressing the adapter into place The bracket around connectors J2 and J3 should fit into the empty space where the blank bracket panel was removed Installing your Ultra320 SCSI Host Adapter 2 3 Ver
30. ration All rights reserved 3 1 Ultra320 Chapter 3 Ultra320 SCSI Host Adapter Characteristics This chapter describes the LSI Logic Ultra320 SCSI to PCI X host adapters This chapter includes these topics e Section 3 1 Ultra320 SCSI to PCI X Host Adapters page 3 1 e Section 3 2 Host Adapter Characteristics page 3 7 e Section 3 3 Technical Specifications page 3 7 SCSI to PCI X Host Adapters PCI X is a high speed standard local bus for interfacing a number of I O components to the processor and memory subsystems in a high end PC The component height on the top and bottom of the Ultra320 SCSI host adapters follow the PC Local Bus Specification Revision 2 2 and PCI X Addendum to the PCI Local Bus Specification Revision 1 0a The Ultra320 SCSI host adapters are used in PCI X and PCI computer systems with PCI standard and PCI low profile bracket types Table 3 1 lists the LSI Logic Ultra320 SCSI host adapters Table 3 1 Ultra320 SCSI 64 bit 133 MHz PCI X Host Adapters Adapter Channel Bracket Board Dimensions LS120320 Single Channel Ultra320 SCSI Standard 6 6 x 2 53 inches 167 6 x 64 3 mm LS1I20320 R_ Single Channel Ultra320 SCSI Standard 6 6 x 2 53 inches 167 6 x 64 3 mm LS1I20320L Single Channel Ultra320 SCSI Low Profile 6 6 x 2 53 inches 167 6 x 64 3 mm LS120320H Single Channel Ultra320 SCSI Standard 6 6 x 3 25 inches 167 6 x 82 6 mm LS121320 Dual Channel Ultra320 SC
31. sia Inc Taiwan Branch LSI Logic Corporation 10 F 156 Min Sheng E Rd Section 3 North American Headquarters Taipei Taiwan R O C Milpitas CA Tel 886 2 2718 7828 Tel 408 433 8000 FAX 886 2 2718 8869 ii Version 2 1 Copyright 2002 2003 by LSI Logic Corporation All rights reserved This document contains proprietary information of LSI Logic Corporation The information contained herein is not to be used by or disclosed to third parties without the express written permission of an officer of LSI Logic Corporation LSI Logic products are not intended for use in life support appliances devices or systems Use of any LSI Logic product in such applications without written consent of the appropriate LSI Logic officer is prohibited Document DB15 000192 01 Version 2 1 July 2003 This document describes the LSI Logic Corporation Ultra320 SCSI to PCI X Host Adapters and will remain the official reference source for all revisions releases of this product until rescinded by an update The PCI and PCI X interface is compatible with the PC Local Bus Specification Revision 2 2 and PCI X Addendum to the PCI Local Bus Specification Revision 1 0a The SCSI interface is compatible with the ANSI draft standard X3T10 11 1142 LSI Logic Corporation reserves the right to make changes to any products herein at any time without notice LSI Logic does not assume any responsibility or liability arising out of the application or use of any prod
32. sion 2 1 Copyright 2002 2003 by LSI Logic Corporation All rights reserved Step 4 Be sure to tighten the bracket screw into the bracket securely before you connect the internal and external SCSI devices 2 2 SCSI Device Cables 2 2 1 2 4 For reliable Ultra320 operation be sure to use an Ultra320 rated SCSI cable The Ultra320 SCSI cable also has built in low voltage differential and single ended termination This built in feature is included because most Ultra320 SCSI hard disk drives are not made with on board low voltage differential termination Internal SCSI Cables You can connect all internal SCSI devices to the host adapter with an unshielded twisted pair 68 pin ribbon cable Some 68 pin internal cables come with a low voltage differential and single ended terminator on one end which must be furthest from the host adapter Figure 2 3 and Figure 2 4 show internal cables with and without a terminator Figure 2 3 SCSI Cable 68 Pin High Density with Terminator Terminator Figure 2 4 SCSI Cable 68 Pin High Density without Terminator Detailed Host Adapter Installation Version 2 1 Copyright 2002 2003 by LSI Logic Corporation All rights reserved 2 2 2 External SCSI Cable You can connect all external SCSI devices to the host adapter with shielded cables You need one 68 pin very high density cable for each device Figure 2 5 shows an example of an external SCSI cable Figure 2 5 SCSI Cable
33. uct described herein except as expressly agreed to in writing by LSI Logic nor does the purchase or use of a product from LSI Logic convey a license under any patent rights copyrights trademark rights or any other of the intellectual property rights of LSI Logic or third parties Copyright 2002 2003 by LSI Logic Corporation All rights reserved TRADEMARK ACKNOWLEDGMENT LSI Logic the LSI Logic logo design Fusion MPT Integrated Mirroring and SureLINK are registered trademarks or trademarks of LSI Logic Corporation Windows and Windows NT are registered trademarks of Microsoft Corporation All other brand and product names may be trademarks of their respective companies KL To receive product literature visit us at http www I silogic com For a current list of our distributors sales offices and design resource centers view our web page located at http www I silogic com contacts index html iii Version 2 1 Copyright 2002 2003 by LSI Logic Corporation All rights reserved iv Version 2 1 Copyright 2002 2003 by LSI Logic Corporation All rights reserved Audience Organization Preface This document is the user s guide for all LSI Logic Ultra320 SCSI to PCI X Host Adapters It contains a functional description of the Ultra320 SCSI host adapters as well as physical and electrical specifications It also contains instructions for installing the host adapters and for connecting SCSI devices to them T
34. you prefer more detailed instructions and guidance refer to Section 2 1 Installing your Ultra320 SCSI Host Adapter page 2 1 To install an Ultra320 SCSI to PCI X host adapter follow these steps Step 1 Turn off and unplug the computer Warning Be sure to disconnect the computer s power before you remove the cover and install the Ultra320 SCSI host adapter Step 2 Open your computer cabinet by removing its cover Step 3 Be sure to touch a grounded metal surface to discharge static electricity before handling the host adapter Step 4 Remove the host adapter from its packaging and examine it for any damage Step 5 Locate an unused PCI X or PCI slot Step 6 Insert your Ultra320 SCSI host adapter into the selected slot Quick Installation Procedures Version 2 1 Copyright 2002 2003 by LSI Logic Corporation All rights reserved Step 7 Step 8 Step 9 Step 10 Step 11 Step 12 Step 13 Step 14 Connect the internal and external SCSI devices to connectors on one SCSI channel Install SCSI bus terminators at the ends of the SCSI bus The SCSI bus must be properly terminated Set the SCSI IDs for all devices and record them for future reference Make any configuration changes Before replacing the cover on your computer verify your installation e Is the host adapter connection in the PCI X or PCI bus slot secure e Are the internal SCSI bus connections secure e Are the external SC