1. Ce 1 MU S 1 x MINI COLOR PAN TILT 1 x 60 DIN EXTENSION DOME CAMERA CABLE 1 x MOUNTING BRACKET 1 x DIN TO BNC RS 485 ADAPTOR CABLE 1 x POWER ADAPTOR FOR 1x HARDWARE MANUAL DIN TO BNC ADAPTOR CHECK YOUR PACKAGE TO CONFIRM THAT YOU HAVE RECEIVED THE COMPLETE SYSTEM INCLUDING ALL COMPONENTS SHOWN ABOVE Camera Connections DIN Cable Camera Connections DIN Cable NOTE Visit us on the web at http www lorexcctv com for a full list of compatible Observation Systems Before installation make sure that e You have the proper lift equipment or ladder to reach the installation location e Electrical power is not connected to the dome camera and surveillance monitor during installation DIN Installation NOTE The camera will only work on CHANNEL 1 when using the DIN Cable connection 1 Connect the 60 ft Din cable included with the dome camera to the wired lead of the dome camera NOTE Confirm that the arrows on the DIN Camera Cable and the DIN Extension cable are pointed together when connecting the cable If the pins in the DIN Connector are bent the Camera will NOT function 2 Attach the adaptor plate on the ceiling using the 3screws provided M3X20 screw The mounting bracket must be attached to a structural object such as a ceiling rafter which will support the weight of the camera 3 Twist the base of the dome camera on to the adaptor plate on the ceil
2. Instruction Manual English Version1 0 MODEL 567381 WWW lorexcctv com Copyright 2007 Lorex Technology Inc Thank you for purchasing this Indoor Mini Color Dome Camera with Pan Tilt control and 3x Digital Zoom Lorex is committed to providing our customers with a high quality reliable security product This camera features a 1 8 Color CCD and Digital Signal Processing DSP allowing for excellent picture quality under varying conditions This compact smoked acrylic dome blends with any d cor and provides discrete video surveillance The motorized controls have the ability to give you a viewing angle of 330 horizontal and 90 vertical This dome camera can connect to any Lorex Color Observation System or DVR with a 6 pin DIN or BNC RS 485 Connection supporting the PELCO D Protocol To learn more about the LCD 8 Channel DVR Combo and to learn about our complete range of accessory products please visit our website at http www lorexcctv com CAUTION RISK OF ELECTRIC SHOCK DO NOT OPEN CAUTION TO REDUCE THE RICK OF ELECTRIC SHOCK DO NOT REMOVE COVER OR BACK NO USER SERVICABLE PARTS INSIDE REFER SERVICING TO QUALIFIED SERVICE PERSONNEL The lightning flash with arrowhead symbol within an equilateral triangle is intended to alert the user to the presence of uninsulated dangerous voltage within the products enclosure that may be of sufficient magnitude to constitute a risk of electric s
3. RH Max 4 21 W x 4 35 H x 4 21 D 107mm W x 110 5mm H x 107mm D 2 5 lbs 1 1 kg Housings Black ABS Plastic Connections e 6pin DIN OR e BNC with RS 485 Adaptor and Power Adaptor Dimensions 4 2in 107mm 1 8in m m s i 92 5in D 62 5mm As our products are subject to continuous improvement LOREX Technology Inc and its subsidiaries reserve the right to modify product design specifications and prices without notice and without incurring any obligation E amp OE
4. he ceiling Do not hold the clear plastic bubble or swivel when you attach the dome to the adapter plate 4 Connect the other end of the 60 ft cable to the BNC RS 485 Adaptor Cable 5 Connect the leads from the Adaptor cable to the inputs on the back of the Observation System the Observation System must include a Pelco D Pan Tilt Zoom feature Connect to Power Adaptor Connect to BNC Input Connect to RS 485 Input 5 Turn on the Observation System or DVR Observation System DVR Connections Connect to RS 485 rede Connections EXC QC DR mud White positive _ 4 TO lt a Black negative Connect to BNC Input Note BNC Adaptors and or RCA Cable may be needed for some systems as shown above Observation System DVR Connections cont Observation System DVR Connections cont Connecting to RS 485 PTZ Connections White RS 485 2 Black RS 485 PTZ AS 232 Note Additional settings are required on the Observation System to control the PTZ Please refer to the Observation System Hardware Manual for menu details Connecting to BNC The BNC end of the cable may be connected directly to the back of the Observation System or DVR In some cases adaptors may be needed for connection BNC to RCA Adaptor RCA Cable BNC to RCA Adaptor Connectivity Diagram Camera DIN Extension DIN to BNC RS 485 Power Adaptor Cable Cable Obse
5. hock The exclamation point within an equilateral triangle is intended to alert the user to the presence of important operating and maintenance servicing instructions in the literature accompanying the appliance WARNING TO PREVENT FIRE OR SHOCK HAZARD DO NOT EXPOSE THIS UNIT TO RAIN OR MOISTURE CAUTION TO PREVENT ELECTRIC SHOCK MATCH WIDE BLADE OF THE PLUG TO THE WIDE SLOT AND FULLY INSERT Please visit us on the web for the most current Manuals Quick Start Guides and Firmware Additional Language Manuals are also available at http www lorexcctv com General Precautions General Precautions 1 All warnings and instructions of this manual should be followed 2 Remove the plug from the outlet before cleaning Do not use liquid aerosol detergents Use a water dampened cloth for cleaning 3 Do not use this unit in humid or wet places 4 Keep enough space around the unit for ventilation Slots and openings in the storage cabinet should not be blocked 5 During lightning storms or when the unit is not used for a long time disconnect the power supply antenna and cables to protect the unit from electrical surge FCC CLASS B NOTICE This equipment has been certified and found to comply with the limits regulated by FCC EMC and LVD Therefore it is designated to provide reasonable protection against interference and will not cause interference with other appliance usage However it is imperative that the user follo
6. ing Do not hold the clear plastic bubble or swivel when you attach the dome to the adapter plate 4 Connect the other end of the 60 ft cable to the CH1 DIN Camera Input on the back of the Observation System the System must include a Pelco D Pan Tilt Zoom feature 5 Turn on the Observation System Camera DIN Extension Observation Cable System Ports CAM 1 CAM CAMS CAMS DIN Port Pins Video Input Audio Out NC Not Connected B 12V Power Audio Input Camera Audio AMP B 12V Power Ground ommoouo Camera Connections DIN to BNC RS 485 Adaptor Cable Camera Connections DIN to BNC RS 485 Adaptor Cable NOTE The camera will work on a BNC channel when using the Adaptor Cable Please refer to the Observation System User manual for details on available channels for PTZ functionality 1 Connect the 60 ft Din cable included with the dome camera to the wired lead of the dome camera NOTE Confirm that the arrows on the DIN Camera Cable and the DIN Extension cable are pointed together when connecting the cable If the pins in the DIN Cable are bent the Camera will NOT function 2 Attach the adaptor plate on the ceiling using the 3screws provided M3X20 screw The mounting bracket must be attached to a structural object such as a ceiling rafter which will support the weight of the camera 3 Twist the base of the dome camera on to the adaptor plate on t
7. m pm C a m e FF FF FF FF FF F F OF OF OF OF OF rr orr Corr orr orr orr orr orr ore orr OFF orr orr Qo Torr or a x H OFF F e F FF FF FF F RI oO Ti e OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF D TI TI Ti nim mimim Im T m pm m pm Ti oO Ti e Calculating the DIP Switch Addresses Each switch in the block has a specific associated value When the switch is turned ON the value is added to the total Switch 1 2 3 4 5 6 7 29 10 Address 1 2 4 8 16 32 64 128 NA NA off off off off l of e 10 Technical Specifications Technical Specifications image Sensor Effective Pixels 768K H x 494K V Scanning System Scanning Frequency 15 734 KHz H x 59 94Hz V Horizontal Resolution Shutter Speed S N Ratio i SEN Digital Zoom Ratio 3x Pan Tilt Speed Pan 50 sec Tilt 40 sec Tilt maximum 90 PTZ Protocol Baud Rate Supported _Minimum Illumination 1 0 lux F1 2 Video Output Power Requirement e From monitor via cable when using DIN only e From power adaptor when using the DIN to BNC RS 485 Adaptor cable Operating Temperature 14 F 122 F 10 C to 50 C Operating Humidity 90
8. rvation System DVR RS 485 BNC Port PTZ Port Changing the Camera Address Settings Changing the Camera Address Settings NOTE This is only applicable when using the BNC Adaptor cable CH1 is the only available channel if using the DIN Connection The DIP switches inside the camera can be changed to set a unique address for the Camera set to 1 by default The address range is between 1 255 e f using a single camera the address does not need to be changed Refer to the Hardware Manual for the Observation System for camera channel placement and configuration e If using multiple cameras each camera must be set to a unique address using the internal DIP switches The DIP switches shown below To access the DIP switches 1 Remove the Dome Cover 2 Use the chart below to set the desired address Set the dip switches ON is up OFF is down using a paperclip or other pointed tool o Default Configuration Switch 1 is ON and all other switches are off The address is 1 DIP Switch Address Chart PEE BE ME HE WE WE WECHE WE WEN Lor OFF ETT CE Ce oF 7 OFF 8 oF oF OFF _ o9 OFF Changing the Camera Adaress Settings DIP Switch Address Chart cont 14 OFF OFF OFF OFF OFF OFF OFF a T ore orr ore orr or OFF OFF OFF OFF oFF 22 OFF OFF orr Cor ore or ore orr 7 e e 2 2 T m rm p
9. ws this manuals guideline to avoid improper usage which may result in damage to the unit electrical shock and fire hazard injury In order to improve the feature functions and quality of this product the specifications are subject to change without notice from time to time http www lorexcctv com Table of Contents Table of Contents Camera HSCS 4 ceting Stared PNE TEE 5 Camera Connections DIN Cable is 6 DINS PO 6 Camera Connections DIN to BNC RS 485 Adaptor Cable 7 Observation System DVR Connections ccccccccseeeeceeeeceeeeeeeeeeseeeeseeesaneesaaes 7 Observation System DVR Connections 8 Connecuvity DATA et teeta a 8 Changing the Camera Address Settings 9 DIP Switch Address Char RAR tas Coo beue desea E utes Ua esa OY onu ert us DOG 9 Calculating the DIP Switch Addresses iii 10 Technical EE 11 DIMENSION O S 11 Camera Features High Resolution Color CCD camera 480 lines 1 0 lux Indoor Pan Tilt Dome System Supports PELCO D Protocol Auto Pan 330 Auto Tilt 90 3x Digital Zoom Light Weight Compact Size 6 pin DIN connection amp BNC RS 485 Adaptor omoked housing provides unobtrusive appearance Getting Started Getting Started The system comes with the following components

Download Pdf Manuals

image

Related Search

Related Contents

Page 1 _ .. Avant d`utiliser ce produit, vérifiez que vous respectez  JVC XV-SA72 DVD Player  Broan-NuTone Broan 689 60 CFM Economy Fan Kitchen Hood  Manuel d`utilisation - SMA Solar Technology AG  DOC TECHNIQUE ( 1661 Ko)  3 Nombre dérivé. Fonction dérivée  Quick Installation Manual    OPENMEETINGS 2.0 - User`s manual  Installation and operating instructions pumped electric shower  