Home

LOREX Technology Dlink DI-624 User's Manual

image

Contents

1. e Set the Private Port to 80 e Set the Public Port to 80 e Set the Schedule to Always and select the Apply button This will create a data path that the Lorex Player will use to access the video stream and will allow you to view the video images If you also want to access the Lorex Monitor using a web browser no changes are required Note to advanced users Web servers are favourite targets of hackers and so using port 80 in this last step may make your Lorex Monitor a little less secure Therefore we recommend returning to this step once you are satisfied with the functionality and changing the settings to use a high port number e g 9002 You will also have to change the Lorex Player and Lorex Monitor settings for this Consult the respective manuals for details Step 2 Register for the Dynamic Domain Name Service DDNS Unless you specifically obtain a static external IP address your broadband Internet address which is assigned by your service provider is subject to change on a regular basis Dynamic DNS is a service from Lorex technology Inc included with your monitor whereby the Lorex Monitor registers the IP address of the router with the external DNS system In order to be able to locate your home network you must sign up to use the Dynamic DNS system Note You need only have one device registering the IP Address of the network If you already have DDNS 2006 Lorex technology Inc p 5 support by a differe
2. 2006 Lorex technology Inc Lorex Monitor Remote Access Setup Guide Dlink DI 624 Date 25 May 2005 Step 1 Before you Start This section will help you in setting up and configuring your Lorex Monitor s and PC s to be able to view the video images from remote locations on the Internet We assume that you already have the monitor hooked up and working and that you can view video from within your Local Area Network LAN If not please consult the Quick Start guide or the Lorex Manual before you continue with remote access setup This document will help you do the following e Configure your router to enable access from outside the LAN Register for the Dynamic Domain Name Service DDNS from Lorex technology Inc Configure the Lorex Monitor to operate with DDNS Set up a password to secure your monitor Configure the Lorex Player to reach the monitor using the DDNS fier BACADBAND INTERNET fj r we 10100 BaseT 10400 Basel NETWORK NETWORK Step1 Configure your router to enable access from the Internet To view video images remotely across the Internet involves setting up your broadband router The example shown here uses the DLink 624 Wireless Broadband Router For routers other than the example shown please consult your router manual and or your router manufacturer s website for technical support Step 1A Log into your Router s Administration Server Use a web browser on a computer that is connected to the LAN side
3. Lorex technology Inc Step 3B Set up a password to secure your module The connection that you currently have is suitable for use on a private Local Area Network If you are concerned that others can get access to your Lorex Monitor you must enable password protection as follows In the left hand panel click on the User option The following screen will appear NETWORK SURVEILLANCE User Management http 192 168 1 12 Back to monitor window System User authorization required Yes ONo Set User Motion Detect Add a user or change password Network Username steven Audio Password eeeee DDns Confirm eecee Set Change Monitor Window Delete user Username steven v Current users list 1 steven 2 admin Enter in a user name and password to create a new user and click on Set change Also click on the admin name under the Current users list Then enter in a new secure password for the administrator and click on the Set change button Make sure you know what the passwords are and be VERY careful not to enter them incorrectly You will need these to access the module from now on Note that these are different passwords from the one used in step 2 to register with DDNS Under User authorization required click on Yes and then Set 2006 Lorex technology Inc Enter a name that indicates that this is for Internet access and define the cameras exactly as before Camera L
4. will appear as shown below 2006 Lorex technology Inc p 7 IP Server Microsoft Internet Explorer File Edit view Favorites Tools Help Back P x a A P Search A Favorites E2 R X N w 7 rel 33 Address http 192 168 45 39 Ctllindex htm Cus Audio v Go Google v BBPSearchwWeb ge E 64blocked E Options NETWORK SURVEILLANCE ve Monn LOREX 2005 1 15 19 16 13 http 192 168 45 39 Change Password View Control high v Quality 320 240 Resolution Indoor amp 6o v Frequency Advanced v lt a ee View Log i Vite tal Configuration z 4 EY ANNY 7 a toa a at Da j i TA Fa J 7 A Ad how Display Mode Activex O Java Delete a camera Watching http 192 166 45 39 Va z LOREX SEE WHAT YOU VE BEEN MISSING Internet Step 3A Set up the DDNS client Click on the Configuration link to bring up the configuration pane and then click on the DDNS link The following screen will appear NETWORK SURVEILLANCE Dynamic DNS http 4192 150 1 12 Back to monitor window System Before configuring DONS you need to visit ddns strategicvistanet User and register a domain name Motion Detect otion Deter Enable Disable rari Password DomainName O08d690021 a3 strategi l State Mot Update honitor Window Dons The Dynamic DNS settings must be entered as d
5. HCP If your router supports this feature you will want to set it up to ensure that the internal IP address never changes In the case of the Dlink 624 click the DHCP button and then click on the DHCP Server Enabled radio button From the DHCP client dropdown list select the entry that corresponds to the Lorex Monitor and click on the 2006 Lorex technology Inc p 3 clone button Click on the Static DHCP Enabled radio button Then click on the Apply button to save this configuration DI 624 nisl asian Wizard Wireless 4 Advanced Tools Status Hel The DI 624 can be setup as a DHOP Server to distribute IP addresses to the LAN network DHCP Server Enabled Disabled Starting IP Address 192 168 1 120 Ending IP Address 192 168 1 199 Lease Time Static DHCP is used to allow DHCP server to assign same IP to specific MAC address Enabled Disabled Name appliance IP 192 168 1 123 MAC Address foo fzo fe f6 feo e7 DHCP Client appliance 00 20 78 16 60 E7 x _Clone 0 00 Apply Cancel Help If your router does not support the Static DHCP feature then you will want to set the IP Address explicitly Choose a new address value that is not already assigned and is outside of the range of the DHCP server to avoid address conflict i e does not fall within the Starting and Ending IP Address Use the new address in the following setup If you do re assign the IP ad
6. computer Wait for the CD to autostart Select the Lorex IP Edit option from the screen If it does not autostart you can manually run the ipedit exe program found in the Lorex Utility directory on the CD This screen will display the IP address of the Lorex Monitor Click on the item in the left hand pane and the 2006 Lorex technology Inc details will be displayed to the right To change any of the highlighted parameters enter in the new values and click Submit For example to enable access port 9002 enter this in the HTTP Port2 field and click Submit LOREX IP EDIT Monitor lists Hane Gateway Te Hetmask HTTP Forti HTTP Port 3002 HAC 00 69 70 63 6D 22 You can change monitor name IP address and Gateway Address 1 Select the Monitor you want to make change 2 Change name Gateway IP address and Netmask on right edit box 3 Press Submit button or Enter 4 Press Update to rescean the installed monitor In order to use the Lorex technology Inc DDNS service you must have signed up with the Lorex technology Inc network in step 2 above You will have received an e mail providing you with the parameters to enter in this part of the setup The Lorex Monitor must be configured using a web browser Double click on the Monitor list item in the Lorex Utility screen above to bring up the web browser Alternatively enter the module s IP address in the browser address bar The Network Surveillance screen
7. dress remember to also set it in the Lorex Monitor using the Lorex Utility See the manual on how to do this Step 1C Create a data path from the Internet to the Lorex Monitor Most routers have a way of setting up forwarding rules to allow external Internet client applications to access devices on the LAN In the case of the DLink 624 router select the Advanced tab and you will see the following screen 2006 Lorex technology Inc D Link Building Networks for People AVI Sa cod High Speed 2 4GHz Wireless Router DI 624 le A Tools Status Hel Virtual Server is used to allow Internet users access to LAN services vu sever Enabled Disabled Name Virtual Server HTTP er me Protocol Type TCP z Filters Private Port 80 Public Port 80 time O1 i 00 AM to or i diii 00 AM iv DMZ day Sun to Sun v i Perlormance amp 3 Apply Cancel Help Name Private IP Protocol Schedule virtual Server FTP 0 0 0 0 TCP 21 21 always Eir Virtual Server HTTPS 0 0 0 0 TCP 443 443 always Eiri Virhial Gamar NANG nanan LINP ANA akuave dial Create a path for your streaming video by entering values as shown e Click the Enabled radio button e Enter the Name this is your choice e Enter the Private IP This must be the same IP address that appears in the LCD of the Lorex Monitor and or the static IP set in the previous step e Set the Protocol Type to TCP
8. escribed in the confirmation e mail When done click on the Submit button at the bottom of the page Note that IP Address updates do take a few minutes to propagate so allow about 15 minutes after setting up the Lorex Monitor s DDNS before expecting to use the system 2006 Lorex technology Inc Step 3B Set up a password to secure your module The connection that you currently have is suitable for use on a private Local Area Network If you are concerned that others can get access to your Lorex Monitor you must enable password protection as follows In the left hand panel click on the User option The following screen will appear NETWORK SURVEILLANCE User Management http 192 168 1 12 Back to monitor window System User authorization required Yes ONo Set User Motion Detect Add a user or change password Network Username steven Audio Password eeeee DDns Confirm eecee Set Change Monitor Window Delete user Username steven v Current users list 1 steven 2 admin Enter in a user name and password to create a new user and click on Set change Also click on the admin name under the Current users list Then enter in a new secure password for the administrator and click on the Set change button Make sure you know what the passwords are and be VERY careful not to enter them incorrectly You will need these to access the module from now on Note that these are different
9. nt means you may not need to do this step Using a web browser go to register lorexcctv net and click on the create account link Account Information E mail Paseyord Password contirm First name Last name Region Mot listed Country United States of America p Timezone Eastern Standard Time EST By clicking on Create Mew Account you accept the Terms of Service Camera Information Product License l OoOo Product Codes sMAC Address Create New Account You will be asked to provide the following information Your e mail address A secret password Your name Your Region state or province Your country Your product license number This is the same number you entered when installing your Lorex Player The license number is made up of 6 to 8 character product code that can be found on the packaging 12 character MAC number that is displayed when running the Lorex Utility program see below Do not include the separating colons After you select Create New Account you will receive a username and password confimation by e mail which you will use in the following steps If you wish to change any of the parameters you may revisit the Registration page However you will be prompted for the existing secret password before you will be allowed access Step 3 Configure the Lorex Monitor for DDNS and Password access Insert the CD into CD reader of your Windows 2000 or Windows XP
10. ocation Camera Server Settings General Address User Cameras Camera Location Mame Internet Camera Server Name Lorex Monitor Camera Server Type Lorex Monitor IPF 5710 cancel care _ In the address field enter the URL as it is specified in the DDNS setup e mail Typically this will be in the format lt MAC gt lorexcctv net In the Port field enter 80 Note if you are setting up an alternate port number e g 9002 then enter that instead Camera Server Settings General Address User Camera Address EA RERE AE Fort fn The User Name and Password will be the same as entered in step 3B above After entering these click Next Camera Server Settings General Address User Cameras User Hame steven Password 4 2006 Lorex technology Inc Camera Server Settings General Address User Cameras En Name Format Size 1 On MJIPG Medium cancel Define the camera as before by clicking the New button and when done click the Finish button Start the video by double clicking on the camera icon and you will be able to view the video as before from anywhere in the world E Lorex Monitor B8 Lorex Monitor ss v Open Camera view al
11. of the router to access your broadband router Typically this will be at an IP Address such as 192 168 1 1 or maybe 192 168 0 1 Consult your router manual for exact details Enter the username and password for your particular router by default the DLink 624 uses admin as the username and the password is blank 2006 Lorex technology Inc Prompt i Enter username and password For DI 624 ak http f 192 168 1 1 User Mame admin Password laa Use Password Manager to remember this password Select a screen display that provides device and or network status In the case of the DLink 624 it will appear as follows Building Networks for People D Link Ali vat lu J a s Home Advanced Tools Firmware Version 1 24 Wed 23 Jul 2003 LAN MAC Address 00 80 C6 16 BB 6F IP Address 192 168 1 1 Subnet Mask 255 255 255 0 DHCP Server Enabled yo i A WAN Wireless MAC Address 00 60 C8 16 BB 70 Connection PPPoE Connected IP Address 65 95 153 236 Subnet Mask 255 255 255 255 Default Gateway 65 95 153 236 DNS 206 47 244 109 206 47 244 137 Wireless 602 11g MAC Address 00 80 C8 2B 63 70 High Speed 2 4GHz Assess Router SEG The status and external IP Address of the router are clearly shown in the WAN section Step1B Set up the Static IP address Some routers including the DLink 624 have the capability to fix the internal IP addresses that are distributed using D
12. passwords from the one used in step 2 to register with DDNS Under User authorization required click on Yes and then Set 2006 Lorex technology Inc Step 3C Setting up an alternate port NETWORK SURVEI System Settrng htip 192 166 1 12 Back to monitor window System Server Wersion Server name Server s time LIser Motion Detect Network Time zone Audio DayLight Dons C MTE Monitor Window Input new time Date Time Http port 1 Http port 2 Jul amp 2004 09 53 50 avC LAB 1 31 2005 20 35 10 Time Zone GMT 05 00 GMT 04 00 BO meaa S Copy PC s time S002 C Reboot immediately Restore factory default configuration RebootilP Server Firmware Update To set an additional port for accessing the Lorex Monitor click on the System link The following screen will appear Enter the alternate port into the Http port 2 field select the Reboot option and click on the Change button Step 4 Configure the Lorex Player The Lorex Player was previously configured for Local Area access by specifying the IP address directly This section will show you how to set this up so that it can access the video from the Internet as well Step 4A Update the Lorex Player for the new password Run the Lorex Player as before From the Servers Cameras panel select the Camera Server and right click on it with your mouse and choose Edit Camera Server 2006

Download Pdf Manuals

image

Related Search

Related Contents

Documenting Process Calibrator  Disfrute EDGE 1.1+ en su proyector 3D DLP sin emisores  User and methodological manual  P01-10(PDF:5048KB  Rexel 1355321  AXi-RGB3 INSTALLATION MANUAL  View File - Graham Field  Household Internet Use Survey: Microdata User Guide  Grèce Algérie, aller-retour  Style guide - Norwegian Cruise Line  

Copyright © All rights reserved.