Home

Linear wt00z-1 User's Manual

image

Contents

1. first RESET UNIT with your controller to remove it from the network Although adding it to a group includes it in the network removing it from a group does not remove it from the network If removed from a group it functions as a repeater only RESET UNIT removes it completely from the network OPERATION Before you can control Z Wave devices you must associate the devices you want to control from the WTO0Z 1 Turning Z Wave devices On or Off 1 Tap the top of the paddle to turn On Z Wave devices 2 Tap the bottom of the paddle to turn Off Z Wave devices The LED on the WT00Z 1 will indicate the status of the devices you are controlling The LED on the WT00Z 1 will flicker when it is transmitting commands to any of the four groups This can be changed See LED Transmission Indication Dimming and Brightening 1 Press and hold the top of the paddle to brighten Z Wave enabled dimmers 2 Press and hold the bottom of the paddle to dim Z Wave enabled dimmers Associating Z Wave devices to control from the WT00Z 1 Refer to your controllers instructions to find out how to associate Z Wave devices You can associate another Z Wave device into any or all of the 4 available groups in the WT00Z 1 The four groups are described below Group 1 Nodes in this group are turned ON by tapping the top of the paddle or OFF by tapping the bottom of the paddle Nodes associated into this group are dimmed by pressing and holdin
2. Byte e Valid Values 0 or 1 default 0 Enable Shade Control Group 3 The WTO00Z 1 can control shade control devices via its group 3 if this configuration parameter is set to 1 e Parameter 15 e Length 1 Byte e Valid Values 0 or 1 default 0 LED Transmission Indication The WTO0Z 1 will flicker its LED when it is transmitting to any of its 4 groups This flickering can be set to not flicker at all set to 0 to flicker the entire time it is transmitting set to 1 or to flicker for only 1 second when it begins transmitting set to 2 By default the WTO0Z 1 is set to flicker for only 1 second e Parameter 19 e Length 1 Byte e Valid Values 0 1 2 default 2 Poll Minutes The WTOOZ 1 will poll the first node in Group 1 in order to keep itself synchronized with the group if this configuration parameter is set to 1 How often it will poll is configured using this parameter e Parameter 20 e Length 1 Byte e Valid Values 1 through 255 default 2 Poll First Node in Group 1 The WTOOZ 1 will poll the first node in Group 1 in order to keep itself synchronized with the group if this configuration parameter is set to 1 e Parameter 21 e Length 1 Byte e Valid Values 0 1 default 0 Each Configuration Parameter can be set to its default setting by setting the default bit in the Configuration Set command See your controller s instructions on how to do this and if it supports it All Configuration commands will be reset to their def
3. act Linear Technical Services at 1 800 421 1587 for an RPA and other important details IMPORTANT Linear radio controls provide a reliable communications link and fill an important need in portable wireless signaling However there are some limitations which must be observed e For U S installations only The radios are required to comply with FCC Rules and Regulations as Part 15 devices As such they have limited transmitter power and therefore limited range A receiver cannot respond to more than one transmitted signal at a time and may be blocked by radio signals that occur on or near their operating frequencies regardless of code settings e Changes or modifications to the device may void FCC compliance Infrequently used radio links should be tested regularly to protect against undetected interference or fault A general knowledge of radio and its vagaries should be gained prior to acting as a wholesale distributor or dealer and these facts should be communicated to the ultimate users P1774 X3
4. ault state when the WTOOZ 1 is reset thus removing it from the Z Wave network SPECIFICATIONS Power 120 VAC 60 Hz Signal Frequency 908 42 MHz Range Up to 100 feet line of sight between the Controller and or the closest EGC Receiver Module INTEROPERABILITY WITH Z WAVE DEVICES A Z Wave network can integrate devices of various classes and these devices can be made by different manufacturers The WT00Z 1 can be incorporated into existing Z Wave networks The top or bottom of the WTOOZ 1 switch paddle can be used to carry out inclusion adding to the network by adding to a group association operate simultaneously with other nodes exclusion remove from a group or reset remove from the network Controllers can be replicated in order to provide operation from other locations REGULATORY INFORMATION The WTOOZ 1 is certified to comply with applicable FCC and IC rules and regulations governing RF and EMI emissions This device complies with part 15 of the FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 This device must accept any interference received including interference that may cause undesired operation FCC NOTICE Note This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interfer
5. ence in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician to help Changes or modifications not expressly approved by the party responsible for compliance could void the user s authority to operate the equipment IC NOTICE This Class B digital apparatus complies with Canadian ICES 003 Cet appareil num rique de la classe B est conforme a la norme NMB 003 du Canada Le pr sent appareil est conforme aux CNR d Industrie Canada applicables aux appareils radio exempts de licence Lexploitation est autoris e aux deux conditions suivantes 1 l appareil ne doit pas produire de brouillage et 2 l utilisateur de l appareil doit accepter tout brouillage radio lectrique subi m me si le bro
6. g the bottom of the paddle until the desired dim level is reached or brightened by pressing and holding the top of the paddle until the desired level is reached The LED on the WT00Z 1 will indicate the status of this group ONLY NOTE Associating nodes into group 2 or 3 will cause a very slight delay before the command is transmitted to group 1 Group 2 Nodes in this group are turned ON by tapping the top of the paddle twice or OFF by tapping the bottom of the paddle twice Nodes associated into this group are dimmed by tapping the bottom of the paddle once and then pressing and holding the bottom of the paddle until the desired dim level is reached or brightened by tapping the top of the paddle once then pressing and holding the top of the paddle until the desire level is reached Group 3 Nodes in this group are turned ON by tapping the top of the paddle three times or OFF by tapping the bottom of the paddle three times Nodes associated into this group are dimmed by tapping the bottom of the paddle twice and then pressing and holding the bottom of the paddle until the desired dim level is reached or brightened by tapping the top of the paddle twice then pressing and holding the top of the paddle until the desired level is reached Group 4 Nodes in this group are turned ON or OFF or set to a specific dim level when the WT00Z 1 is controlled remotely You can place up to 5 nodes in each group If controlling dimmers for best results as
7. g to devices that are associated into Group 4 e Parameter No 2 e Length 1 Byte e Valid Values 0 or 1 default 0 Night Light The LED on the WT00Z 1 will by default turn ON when the status of the devices in Group 1 is ON To make the LED turn ON when the status of Group 1 is OFF set this parameter to a value of 1 e Parameter No 3 e Length 1 Byte e Valid Values 0 or 1 default 0 Invert Switch To change the top of the transmitter to OFF and the bottom of the transmitter to ON set parameter 4 to 1 To change back to original settings set this parameter to the value of 0 e Parameter No 4 e Length 1 Byte e Valid Values 0 or 1 default 0 Ignore Start Level When Receiving Dim Commands The WTO0Z 1 can send Dim commands to Z Wave enabled dimmers The Dim command has a start level embedded in it A dimmer receiving this command will start dimming from that start level However the command can be sent so that the dimmer ignores the start level and instead start dimming from its current level By default the WTOOZ 1 sends the command so that the dimmer will start dimming from its current dim level rather then the start level embedded in the command To change this simply set the configuration parameter to 0 e Parameter No 5 e Length 1 Byte e Valid Values 0 or 1 default 1 NOTE This only affects a level that is reported or possibly sent by the WTO00Z 1 since the WT00Z 1 does not control a load Adjusting Dim Rate F
8. near Building On Innovation WT00Z 1 Radio Frequency RF Controlled 120 VAC Wall Mounted Transmitter Series 300 NEUTRAL WHITE 120 VAC BLACK LINE TO MOUNT MORE THAN ONE WTOOZ 1IN A BOX SCORED TAB PUSH ON PUSH WILL BREAK FLUSH WITH EDGE amp HOLD TO BRIGHTEN OF PLASTIC ee PUSH AND HOLD TO DIM PUSH TOP OR C UL US BOTTOM OF PADDLE GREEN GROUND SWITCH ONCE TO LISTED SUPPLIED WITH DECORATIVE SWITCH PLATE INCLUDE IN NETWORK NOTE This module must be included in the Network only where it will be permanently installed The proper operation of this node in the mesh network is dependent on it knowing its location with respect to other nodes You cannot test bench configure this module WTOOZ 1 WALL MOUNTED TRANSMITTER Linear s family of Z Wave certified wireless lighting controls switches dimmers outlets and plug in modules brings a new level of intelligent wireless capability to commercial and residential environments The Z Wave wireless protocol is an international wireless standard for remote home automation security and other applications Embedded in each device the Z Wave smart chip enables two way RF communication among hundreds of Z Wave enabled devices allowing products and services from multiple manufacturers to work seamlessly Linear Z Wave products are easy to install and allow dealers to create an integrated wireless network with nearly limitless expa
9. nsion and interoperability with security and health monitoring systems energy management home entertainment appliances and more INSTALLATION DANGER SHOCK HAZARD Read and understand these instructions before installing This device is intended for installation in accordance with the National Electric code and local regulations in the United States or the Canadian Electrical Code and local regulations in Canada It is recommended that a qualified electrician perform this installation Retain instructions for future use With power off wire this WTO00Z 1 according to the diagram shown above If more than one WTOOZ 1 is to be installed in a wall box scored tabs on the side can be broken off by bending back and forth with pliers to accommodate proper fit Apply power when completed Refer to your Controller operating instructions on how to include this module in the RF network INCLUDING WT00Z 1 TO THE NETWORK STEP 1 Prepare the Controller to include a unit to the network by adding it to a group method of adding a node to the network Refer to controller instructions STEP 2 The WTO00Z 1 must be in its permanently installed location Tap either the top or bottom of the WT00Z 1 once STEP 3 You should see an indication on your Controller that the device was included in the network NOTE If you have trouble adding the WTO0Z 1 to a group it may be that the Home ID and Node ID were not cleared from it after testing You must
10. or example There are 3 sets of parameters that can adjust the dimming rate of the WT00Z 1 1 One set to control how fast the dim rate is when the dimmer receives a Z Wave command excluding ALL ON or ALL OFF command 2 One set to control how fast the dim rate is when the dimmer is locally controlled 3 One set to control how fast the dim rate is when the dimmer receives an ALL ON or ALL OFF command These values can be changed instantly to allow various scenes and effects The first of these parameters is the dim step dim rate parameter It can be set to a value of 1 to 99 This value indicates how many levels the dimmer will change when the timer discussed below expires The second parameter is the timing how fast the dim rate parameter It can be set to a value of 1 to 255 This value indicates in 10 millisecond resolution how often the dim level will change For example if you set this parameter to 1 then every 10mS the dim level will change If you set it to 255 then every 2 55 seconds the dim level will change With the combination of the two parameters that can control the dim rate the dimmer can be adjusted to dim from maximum to minimum or minimum to maximum at various speeds between 10 millisecond and 252 45 seconds over 4 25 minutes e Parameter 7 12 e Length 1 Byte e Valid Values See next NOTE that this only affects a level that is reported or possibly sent by the WT00Z 1 since the WT00Z 1 does not con
11. sociate the dimmers into the group first CONFIGURATION The WT00Z 1 supports the Configuration command The WT00Z 1 simulates the operation of a dimmer Using configuration commands you can adjust the dimming parameters as though it were a dimmer The WT00Z 1 can be configured to operate slightly differently than how it works when you first install it Using the configuration command you can change operational characteristics Set Ignore Start Level Bit When Transmitting Dim Commands The WTO0Z 1 can send Dim commands to Z Wave enabled dimmers The Dim command has a start level embedded in it A dimmer receiving this command will start dimming from that start level However the command can be sent so that the dimmer ignores the start level and instead starts dimming from its current level By default the WTO0Z 1 sends the command so that the dimmer will start dimming from its current dim level rather than the start level embedded in the command To change this simply set the configuration parameter to 0 e Parameter No 1 e Length 1 Byte e Valid Values 0 or 1 default 1 NOTE Any ACT Z Wave enabled dimmers have the configuration option to ignore the start level no matter how you configure the WTO0Z 1 Suspend Group 4 You may wish to disable transmitting commands to Z Wave devices that are in Group 4 without un associating those devices from the group Setting parameter 2 to the value of 1 will stop the WTO0Z 1 from transmittin
12. trol a load On Off Command dim rate excluding ALL ON ALL OFF commands e Parameter 7 e Dim step Parameter default 3 e Valid Values 1 99 e Parameter 8 Dim timer Parameter default 10 e Valid Values 1 255 Local Control dim rate Parameter 9 Dim step Parameter default 3 Valid Values 1 99 Parameter 10 e Dim timer Parameter default 10 e Valid Values 1 255 ALL ON ALL OFF dim rate e Parameter 11 e Dim step Parameter default 3 e Valid Values 1 99 e Parameter 12 e Dim timer Parameter default 10 e Valid Values 1 255 Disable Group 4 During a Dim Command After the WT00Z 1 is commanded to stop dimming when dimming because of the DIM START command it will then command the Z Wave devices that are in Group 4 to its new level To prevent the WT00Z 1 from commanding the Z Wave devices in Group 4 during this particular occurrence set Parameter 13 to the value of 1 e Parameter 13 e Length 1 Byte e Valid Values 0 or 1 default 0 NOTE This only affects a level that is reported or possibly sent by the WT00Z 1 since the WT00Z 1 does not control a load Enable Shade Control Group 1 The WTO0Z 1 can control shade control devices via its group 1 if this configuration parameter is set to 1 e Parameter 16 e Length 1 Byte e Valid Values 0 or 1 default 0 Enable Shade Control Group 2 The WTO0Z 1 can control shade control devices via its group 2 if this configuration parameter is set to 1 e Parameter 14 e Length 1
13. uillage est susceptible d en compromettre le fonctionnement Cet appareil num rique de la classe B est conforme a la norme NMB 003 du Canada Operation is subject to the following two conditions 1 this device may not cause interference and 2 this device must accept any interference including interference that may cause undesired operation of the device Copyright 2013 Linear LLC 234730 AX2 WARRANTY This Linear product is warranted against defects in material and workmanship for twelve 12 months This warranty extends only to wholesale customers who buy direct from Linear or through Linear s normal distribution channels Linear does not warrant this product to consumers Consumers should inquire from their selling dealer as to the nature of the dealers warranty if any There are no obligations or liabilities on the part of Linear Corporation for consequential damages arising out of or in connection with use or performance of this product or other indirect damages with respect to loss of property revenue or profit or cost of removal installation or reinstallation All implied warranties including implied warranties for merchantability and implied warranties for fitness are valid only until Warranty Expiration Date as labeled on the product This Linear LLC Warranty is in lieu of all other warranties express or implied All products returned for warranty service require a Return Product Authorization Number RPA Cont