Home

Linak MEDLINE MJB User's Manual

image

Contents

1. Safety instructions A Safe use of the system is possible only when the operating instructions are read completely and the instructions contained are strictly observed Failure to comply with instructions marked with the NOTE symbol may result in serious damage to the system or one of its components Persons who do not have the necessary experience or knowledge of the product products must not use the product products Besides persons with reduced physical or mental abilities must not use the product products unless they are under surveillance or they have been thoroughly instructed in the use of the apparatus by a person who is responsible for the safety of these persons Moreover children must be under surveillance to ensure that they do not play with the product pal It is important for everyone who is to connect install or use the systems to E have the necessary information and access to this User Manual ia If there is visible damage to the product it must not be installed pal The appliance is not intended for use by young children or infirm persons without supervision A Young children should be supervised to ensure that they do not play with the appliance Residual risk A N sore of the products contains software based components LINAK has made various possible efforts to assure that the software is free of errors and that the software has been developed according to the rules of IEC 60601 1 4 software in Medical
2. 1 Relay 1 CB power mode Alarm level Relay state Mains unplugged CB is in power down or the OpenBus is not Alarm running Clock data is missing On mains or battery at wake up Bed Alarm V Relay 2 CB power mode Mains unplugged or CB is in power down On mains or battery at wake up When the mains is unplugged or CB is in power down will the relay shift to NC state and generate alarm Alarm generated by nurse call or bed alarms Example of closed loop 31 party site MJB In this state no Alarm Example of Open Loop 3 party site MJB In this state no Alarm 12 Precautions A Always use locking mechanism and O ring Sockets not used must be fitted with blind plugs to ensure IP Degree When using the modular plug with open end is it up to the customer to maintain the IP degree If the MJB Gateway is used as open loop there is a risk of not sending an alarm when no mains are connected The MJB Gateway will only send an alarm if mains is missing when using a Closed Loop see functionality description When the Gateway is used on a system with battery SP Power mode Gateway the gateway functionality will follow the power On mains Function ok down mode of the control box see table Sten Power down No function Wake Up Function ok The MJB Gateway is not to be used as safety it is only to be used as a guided system It is important to test the s
3. 504 02 see description on the next pages Relay1 NC normally closed Pin 2 Pin 1 NO normally open Pin 2 Pin 3 Relay2 NC normally closed Pin 5 Pin 4 NO normally open Pin 5 Pin 6 Relay 1 is NO when connected to the mains and NC when no mains this means the relay is active when connected to the mains closed loop The Closed Loop principal is to ensure that an alarm is sent if power is missing on the bed When the mains is disconnected power is missing the relay will go from NO to NC which will automatically result in an alarm status indicator on the OpenBus Relay 1 can be activated via the patient control Key1 Key4 or the attendant control Key2 Key3 When a key is activated the relay will switch state from NO to NC for 2 seconds After 2 seconds the relay will automatically change state from NC to NO The status of the relay is indicated on the OpenBus and can be used for switching on an LED Relay 2 is as default NC with or without mains Open Loop Relay 2 can be activated via the patient control Key 1 or the attendant control Key 2 Key 3 When the relay is activated it will switch from NC to NO for 2 seconds After 2 seconds the relay will automatically change state from NO to NC The status of the relay is indicated on the OpenBus and can be used for switching on an LED 10 By using the variant 504 02 relay 2 will be controlled by the MJB variant 505 506 with switch i
4. Make sure that the voltage of the control box is correct before the system is connected to the mains e System connection The individual parts must be connected before the contro box is connected to the mains During operation e Ensure that the cables are not damaged e Unplug the mains cable on mobile equipment before it is moved Information on the MJB The MJB Modular Junction Box is designed for use together with OpenBus control boxes The MJB makes it possible to connect multiple handsets attendant controls or it makes it possible to use the MJB as a control unit for 3 party products as Out of Bed detection USB charger Under Bed Light etc products other than LINAK products i e products from 3 party suppliers or LINAK A S delivers only the OpenBus system and is not responsible for any the compliance of such products with the LINAK OpenBus system Repairs In order to avoid the risk of malfunction all repairs must only be carried out by authorised LINAK workshops or repairers as special tools must be used and special gaskets must be fitted Products under warranty must also be returned to authorised LINAK workshops Warning A If any of the LINAK products are opened there will be a risk of subsequent malfunction Disposal of LINAK s products LINAK s products may be disposed of possibly by dividing them into different waste groups for recycling or combustion We recommend that our product is disassembled
5. in during cleaning to prevent the ingress of water Precaution Its When cleaned water must never be sprayed upwards from underneath the MP bed because it may enter the cable outlet Environmental conditions Temperature 5 C to 40 C Relative humidity 20 to 90 30 C not condensing Atmospheric pressure 700 to 1060 hPa rage Temperature 10 C to 50 C Relative humidity 20 to 90 30 C not condensing Atmospheric pressure 700 to 1060 hPa Valid where nothing otherwise is stated under the specific products in a later section 16 Modular plug with wide slit To be used with LINAK products Can be connected to all ports in the MJB both ports with narrow and wide slit E E A m Modular plug with narrow slit To be used with 3 party products Can only be connected to ports in the MJB with narrow slit This is to prevent 3 party products to interfere with the OpenBus connections 17 Key to symbols The following symbols are used on the label on the LINAK products Type B equipment as per EN 60601 1 Lock function 2 Protection against contact foreign Release function IPXX matter first character and water second character as per EN60529 Charasindieator Class 2 equipment 4 For indoor use 8 Double insulated transformer dh Protective earth Safety switch enable button r 3 P o Alternating Current BERE Direct current Attention consult accompanying docum
6. linak us com SUBSIDIARIES AUSTRALIA LINAK Australia Pty Ltd Phone 61 3 8796 9777 Fax 61 3 8796 9778 E mail sales linak com au www linak com au AUSTRIA LINAK GmbH Austria Phone 43 0 2266 61 9 62 Fax 43 0 2266 63 2 99 E mail info linak de www linak at BELGIUM amp LUXEMBOURG LINAK Actuator Systems NV SA Phone 32 0 9 230 01 09 Fax 32 0 9 230 88 80 E mail info linak be www linak be BRAZIL LINAK DO BRASIL COM RCIO DE ATUADORES LTDA Phone 55 11 2832 7070 Fax 55 11 2832 7060 E mail info linak com br www linak com br CANADA LINAK Canada Inc Phone 1 502 253 5595 Fax 1 905 821 4281 E mail info linak ca www linak ca CZECH REPUBLIC LINAK C amp S S R O Phone 420581741814 Fax 4420581702452 E mail ponizil linak cz www linak cz DENMARK LINAK DANMARK A S Phone 45 86 80 36 11 Fax 45 86 82 90 51 E mail linak linak silkeborg dk www linak dk FINLAND LINAK OY Phone 358 10 841 8700 Fax 358 10 841 8729 E mail linak linak fi www linak fi FRANCE LINAK FRANCE E U R L Phone 33 0 2 4136 3434 Fax 33 0 2 4136 3500 E mail linak linak fr www linak fr GERMANY LINAK GmbH Phone 49 6043 9655 0 Fax 49 6043 9655 60 E mail info linak de www linak de INDIA LINAK A S Asian Representative Office Phone 91 120 4797013 E mail info linak in www linak in IRELAND LINAK UK Limited Phone 44 0 121 544 2211 Fax 44
7. of course but the expected service life in a specific application is very dependent on how the products are used Maintenance e The LINAK products must be cleaned at regular intervals to remove dust and dirt and inspected for mechanical damage wear and breaks e The LINAK MJB is a closed unit and requires no internal maintenance e PX6 is waterproof e Make sure that the plugs in the MJB are correctly fitted with O rings before washing e Electronics must be inspected at attachment points wires cabinet and plugs e Inspect the connections cables cabinet and plugs and check for correct functioning MJB GATEWAY variant 504 01 amp 504 02 The MJB is a simple gateway interface which can connect the bed to the infrastructure of the hospital or nursing homes The Gateway can be used in combination with an Out of Bed Sensor which makes it possible to indicate if the patient leaves the bed The Gateway can also be used as a service nurse call system Please note it is only to be used as a guided system not for emergency issues Port 5 Relay connetions Relay 1 EN Pin 1 NC EK Ports gt Pn2 _ e d Pin 3 J NO Relay 2 Pin4 INC LH Port OpenBus connetion Standard functionality The MJB Gateway consist of two relays which are connected through Port 5 on the MJB This can be made with the special cable 0964140 Modular plug Open end There are as standard 2 configurations 504 01 and
8. the Gateway MJB IP Protection degree All LINAK products can be cleaned as follow according to their IP protection which is stated on the product label The IP code specifies the degrees of protection provided by the enclosures Only the protection against ingress of water second characteristic numeral is specified ingress of solid foreign objects first characteristic numeral is not specified and therefore replaced by the letter X in the code must not be hosed down directly with a high pressure cleaner Max 209C The materials are resistant to the majority of cleaners and disinfectants used in the hospital and nursing home sector Cleaning with a steam cleaner for example is not permitted as it will not be possible to maintain a minimum distance of 300 mm from the electrical parts The following directions regarding cleaners and disinfectants must be complied with e hey must not be highly alkaline or acidic pH value 6 8 e They must not contain caustic agents e heir contents must not be able to change the structure of the surface or adhesion of the plastic e hey must not break down grease The following disinfectants detergents are recommended e Neodischer Dekonta dosage 1 396 made by CHEMISCHE FABRIK Dr WEIGERT e CCOTRADE RW dosage 0 596 made by CCOTRADE GmbH Warning The systems must not be sprayed directly with a high pressure cleaner Warning A Interconnecting cables must remain plugged
9. 0 121 544 2552 E mail sales linak co uk www linak co uk ITALY LINAK ITALIA S r l Phone 39 02 48 46 33 66 Fax 39 02 48 46 82 52 E mail info linak it www linak it JAPAN LINAK K K Phone 81 45 533 0802 Fax 81 45 533 0803 E mail linak linak jp www linak jp MALAYSIA LINAK A S Asian Representative Office Phone 60 4 210 6500 Fax 60 4 226 8901 E mail info linak asia com www linak asia com NETHERLANDS LINAK Actuator Systems B V Phone 31 76 5 42 44 40 Fax 31 76 5 42 61 10 E mail infoGlinak nl www linak nl NEW ZEALAND LINAK New Zealand Ltd Phone 64 9580 2071 Fax 64 9580 2072 E mail nzsales linak com au www linak co nz NORWAY LINAK Norge AS Phone 47 32 82 90 90 Fax 47 32 82 90 98 E mail info linak no www linak no POLAND LINAK Polska Phone 48 22 500 28 74 Fax 48 22 500 28 75 E mail dkreh linak dk www linak pl SPAIN LINAK Actuadores S L u Phone 34 93 588 27 77 Fax 34 93 588 27 85 E mail linakact linak es www linak es SWEDEN LINAK Scandinavia AB Phone 46 8 732 20 00 Fax 46 8 732 20 50 E mail infoGlinak se www linak se SWITZERLAND LINAK AG Phone 41 43 388 31 88 Fax 41 43 388 31 87 E mail info linak ch www linak ch TAIWAN LINAK A S Taiwan Representative Office Phone 886 2 250 80296 Fax 886 2 2508 3604 E mail info linak com tw www linak com tw TURKEY LINAK A S Turkey Representative Office P
10. Care and Health Comfort furniture Desk and Industry areas Yet LINAK cannot know all the conditions under which LINAK products will be installed used and operated as each individual application is unique The suitability and functionality of the LINAK product and its performance under varying conditions application vibration load humidity temperature frequency etc can only be verified by testing and shall ultimately be the responsibility of the LINAK customer using any LINAK product It is also the responsibility of the LINAK customer to make and supply a comprehensive user manual of the application LINAK shall be responsible solely that the LINAK products comply with the specifications set out by LINAK and it shall be the responsibility of the LINAK customer to ensure that the specific LINAK product can be used for the application in question 21 22 23 FACTORIES CHINA LINAK Shenzhen Actuator Systems Ltd Phone 86 755 8610 6656 Fax 86 755 8610 6990 E mail sales linak cn www linak cn DENMARK LINAK A S Group Headquarters Guderup Phone 45 73 15 15 15 Fax 45 74 45 80 48 Fax Sales 45 73 15 16 13 E mail info linak com www linak com SLOVAKIA LINAK Slovakia s r o Phone 421 517563 414 Fax 421 517563 410 E mail jp linak sk www linak com USA LINAK U S Inc North and South American Headquarters Phone 1 502 253 5595 Fax 1 502 253 5596 E mail info linak us com www
11. Fax 82 2 3453 1177 E mail unitekeng unitekeng co kr www unitekeng co kr UNITED ARAB EMIRATES Mechatronics Phone 971 4 267 4311 Fax 971 4 267 4312 E mail mechtron emirates net ae www mechatronics ae For contact details on other countries please visit www linak com or contact LINAK INTERNATIONAL Fax 45 74 45 90 10 E mail info linak com www linak com Terms of use The user is responsible for determining the suitability of LINAK products for specific application LINAK takes great care in providing accurate and up to date information on its products However due to continuous development in order to improve its products LINAK products are subject to frequent modifications and changes without prior notice Therefore LINAK cannot guarantee the correct and actual status of said information on its products While LINAK uses its best efforts to fulfil orders LINAK cannot for the same reasons as mentioned above guarantee the availability of any particular product Therefore LINAK reserves the right to discontinue the sale of any product displayed on its website or listed in its catalogues or other written material drawn up by LINAK All sales are subject to the Standard Terms of Sale and Delivery for LINAK For a copy hereof please contact LINAK LINAK LINAK A S reserve the right to make technical alterations Copyright 9 LINAK 2010 10 MA M9 02 348 WE IMPROVE YOUR LIFE
12. MEDLINE CARELINE IMPROVING EFFICIENCY IMPROVING EFFICIENCY MJB Gateway LINAK WE IMPROVE YOUR LIFE To learn more about LINAK please visit Contents A DU 4 Important IntornmoalOH tierra AA Rede tr dates ees 5 Safety instructions oo e RR EENE N UD E ED RR EREMO CNN VERE ERE T Y cR EAS 5 Residual isle in tt sz 6 Before installation reinstallation or troubleshooting ssssssssss mee 7 Betore start up en RE E LEER 7 During Operation EA rs MEI ale REES 7 IMTOrmation on the MB zu nen SI ER ee y Repais meer et md onsite n b IL Lt tc uM eM re 8 Misc on the MIB System o oreet adm emite UE te Ceu MM LE eth de arta 9 WV aL SIGS a AA eier ie 9 Maintenance utes cubes LUI Mt LM LIED uM LC ta 9 MJB GATEWAY Valant eo A ur eeu Er cce AERE IA LUE c O 10 O ie 10 Lc dM ajos PM CET 10 lisi IDE 11 Options Speciale article te ac csse e a ee En do Na 11 Sc IM ee ea les ss sn EP 11 PRECAUTIONS ss NT 13 IP Protection degree nn en se en else al lesen leiser Hottie 15 Environmental conditions dar ee einen det 16 Modular plug with wide and narrow slit em nennen 17 Keys to symbols esce ott t teu e e LU a es aa ee 18 Drawing appendix ii ae ee 20 Addresses a 24 Preface We are delighted that you have chosen a product from LINAK LINAK systems are high tech products based on many years of experience in the manufacture and development of actuators electric control boxes control
13. as much as possible at the disposal and that you try to recycle it As an example of main groups within sorting of waste we can mention the following Metal plastic cable scrap combustible material and collection for recoverable resources Some of these main groups can be sub divided into groups e g metal can be divided into iron stainless steel and aluminium and alloy steel Plastic can e g be divided into ABS PA PE and PP The MJB can be disassembled and sorted into the following recycling groups Plastic housing Plastic recycling or combustion MJB Cable Cable scrap or combustion PC board Electronics scrap By now all our casted plastic units are provided with an interior code for plastic types and fibre contents if any Misc on the MJB system Warranty and service life The LINAK warranty covers manufacturing defects in the products starting from the date of manufacture There is 18 months warranty for MEDLINE and CARELINE products The warranty is limited to the value of the LINAK product LINAK s guarantee is only valid so far as the products have been used and maintained correctly and has not been tampered with Furthermore the products must not be exposed to violent treatment In the event of this the warranty will be ineffective invalid LINAK s warranty is only valid if the system is unopened and has been used correctly All LINAK products are designed to have an optimum service life as a matter
14. ents 18 O APPROVAL V94265 APPROVAL NO 97122 ee I U V Bauart gepr ft PRODUCT SERVICE cmn ATTE nes creen TELE i CS95145V LGABI Uy Du 4 LISTED Demko approval Fimko approval Australian approval mark Australian approval mark Recognised Component Mark Canadian Recognised Component Mark Recognised Component Mark for Canada and the United States T Mark RW T v approval T v Produkt Service T VRheinland ETL C ETL LGA UL Listing Mark C UL Listing Mark C UL US Listing Mark UL Listing Mark File E97199 File E175209 File E191104 O p x Eod aha A A On i UL file number UL file number UL file number CSA PSE Mark Product with a thermofuse For indoor use House Safety isolating transformer Electronics scrap Equipment Kl 2 Double square Patient part of type B Mand Patient part of type BF Earth protection Equipment class1 Earth CE Mark C TICK 19 DRAWING APPENDIX MJB Modular Junction Box MJB oro he 7 0 QU o 20 LINAK APPLICATION POLICY The purpose of the application policy is to define areas of responsibilities in relation to applying a LINAK product defined as hardware software technical advice etc related to an existing or new customer application LINAK products as defined above are applicable for a wide range of applications within the
15. hone 90 312 4726338 59 Fax 90 312 4726635 E mail vozen linak com tr www linak com tr UNITED KINGDOM LINAK UK Limited Phone 44 0 121 544 2211 Fax 44 0 121 544 2552 E mail sales linak co uk www linak co uk DISTRIBUTORS ARGENTINA NOVOTEC ARGENTINA SRL Phone 54 11 4303 8900 89 Fax 54 11 4032 0184 E mail info novotecargentina com www novotecargentina com COLOMBIA MEM Ltda Phone 57 1 334 7666 Fax 57 1 282 1684 E mail servicioalcliente memltda com co www memltda com co INDONESIA PT HIMALAYA EVEREST JAYA Phone 6 221 544 8956 65 Fax 6 221 619 4658 1925 E mail hejplastic div centrin net id www hej co id IRAN Bod Inc Phone 98 2188998635 6 Fax 98 2188954481 E mail info bod ir www bod ir MEXICO ILSA S A de C V Phone 52 55 5388 3960 Fax 52 55 5388 3966 E mail linak ilsamexico com www ilsamexico com PERU PERCY MARTIN DEL AGUILA UBILLUS Phone 51 99 883 9879 RUSSIAN FEDERATION 000 FAM Phone 7 812 3319333 Fax 7 812 3271454 E mail purchase fam drive ru www fam drive ru SINGAPORE SERVO DYNAMICS PTE Ltd Phone 65 6844 0288 Fax 65 6844 0070 E mail servodynamics servo com sg www servo com sg SOUTH AFRICA Industrial Specialised Applications CC Phone 27 11 312 2292 or 27 11 2077600 Fax 27 11 315 6999 E mail garthtGisagroup co za www isaza co za SOUTH KOREA UNITEK ENG Phone 82 2 567 0888
16. nput Alarm 1 2 Switch input S2 OoBD alarm Alarm 2 Switch input S1 When using this combination is it important to have the MJB 505 506 connected to the system all the time If it is not connected the Gateway MJB will see it as an alarm and the relay will be activated The Gateway MJB is scanning the OpenBus system every minute for an alarm Features e Add on value for hospital amp care bed e Compact and functional design which allows easy mounting e 2 connections Port1 OpenBus M connection Port 5 Gateway e Colour Light grey RAL 7035 e Protection class IPX6 e Connection to OpenBus M control box via modular plug cable 6 wires e Modular plug to Open end see precautions Options special article e Customised SW It Is possible to define the OpenBus M signals to be used for activating the relays and or change the alarm indicator so that it fits to the customers system Please contact your Sales Engineer at LINAK A S for further information Usage e Compatible with all LINAK OpenBus Control Boxes light amp full Contact rating e Max continuous current IA e Maximum switching voltage 125V DC 125V AC e Maximum switching capacity 24W DO 62 5VA AC e Contact resistance lt 100 MQ Current consumption e V bus 8V 9 mA e V permanent 40V 14 mA e Approvals LINAK and UL International DEMKO A S are currently in the process of certifying the MJBXOX re UL60601 and EN60601
17. pecified alarms is working in the correct way before sending the system to the end user Do not use 2 MJB variants with same device ID on the OpenBus M This will cause conflicts and the SDT is not able to identify the different products attached Before the final functional test in the production it is important that the system Is re powered This is to ensure that all items have been detected on the OpenBus M We recommend the end user to make a regular test procedure in order to prevent failures and hazardous situations on the system e g defective OOB sensor squeezed cables The MJB is not able to detect defective 3 party products LINAK only takes responsibility for LINAK products not 3 party products Please pay attention to the Patient Environment Clause 3 79 EN60601 1 3 edition Any volume in which contact can occur between a patient and parts of the medical equipment or between a patient and other persons touching parts of the equipment Justified practice here is 1 5 m This volume must be subject to the Risk Analysis It is important to inform the customer about this There can be a risk of conflict with other OpenBus accessories such as HB ACP etc It is therefore recommended to make a system bit overview 13 Cable ordering nos Modular plug open end 0964140 3000 Please note the slit is placed on the opposite side of the modular plug This is to ensure that the cable is only being used for
18. products That involves Risk Analysis which shows a small residual risk for unwanted unintended movement of actuators under specific conditions According to the above rules it must be informed and if necessary considered in the Risk analysis of the final application More details to residual risk can be provided by LINAK if necessary Warning The plastic parts in the system cannot tolerate cutting oil Warning LINAK s actuators and electronics are not constructed for use within the following fields e Planes and other aircrafts e Explosive environments e Nuclear power generation Warning If faults are observed the products must be replaced Warning Never spray directly on the products with a high pressure cleaner Warning Always insure that the patient is accessible in case of emergency Warning Cables must be secured safely so that persons cannot get trapped in it Warning Always use locking mechanism and O ring Warning Sockets not used must be fitted with blind plugs to ensure IP degree pal The LINAK products cannot tolerate the influence of strong solvents basic or g alkaline liquids Before installation re installation or troubleshooting e Stop the application e Switch off the power supply and pull out the mains plug e Relieve the application of any loads which may be released during the work Before start up e Make sure that the system has been installed as instructed in the User Manual e
19. s and chargers This User Manual will tell you how to install use and maintain your LINAK equipment We are sure that your LINAK system will give you many years of problem free operation Before our products leave the factory they undergo full function and quality testing Should you nevertheless experience problems with your systems you are always welcome to contact your local dealer LINAK subsidiaries and some distributors situated all over the world have authorised service centres which are always ready to help you LINAK provides a warranty on all its products This warranty however is subject to correct use in accordance with the specifications maintenance being done correctly and any repairs being carried out at a service centre which is authorised to repair LINAK products Changes in installation and use of LINAK systems can affect their operation and durability The products are not to be opened by unauthorised personnel The User Manual has been written on the basis of our present technical knowledge We are constantly working on updating the information and we therefore reserve the right to carry out technical modifications LINAK A S Important information Description of the various signs used in this manual Warning Failure to comply with these instructions may result in accidents involving serious personal injury pal Failing to follow these instructions can result in the product being damaged or ME destroyed