1.           FIELD CUTTING TRACK    e Remove and save the Dead End Cover     Cut the track using a metal cutting blade  preferably in a miter box to  obtain a square cut    e Remove ALL burrs and sharp edges from the cut surface of the track  being careful not to destroy the integrity of the track geometry  There  should be no burrs between the copper wire s  and the aluminum track  housing    e  f an electrical connector is being installed into the cut section  open  the GAP of all copper wires using a wedging tool  such as a flat blade  screwdriver   CAUTION  DO NOT OPEN THE GAP MORE  THAN 3 16  FROM THE EDGE OF THE TRACK EXTRUSION    e Insert the Dead End Cover into the end of the track run     Recessed ProSpec    Track        lt    Structural  Mini Coupler or Out    Impediment  In Line Connector Se 7A    Feed Track Te       VW Ds   i    Feed Track  or Power Extension  Connector    Feed Taek     Extension      Feed Track  Connector i  or Power Extension   Connector    Extension Plain Track      Connector Power      Extension TRS  Connector Feed Track  or Power Extension  Connector    Connector             Aaaa Track Housing  SS s    LY 2    Open copper conductor  gap after cutting    lie Open gap 3 16  max     from track edge  Typical  for all copper wires     Dead End             
2.  Do not install in wet media  concrete  plaster  etc      e This track system is intended for installation in accordance with the National  Electrical Code and Local or Federal Codes   Do not install this track in wet or damp locations   Do not install any part of this track system less than 5 feet above floor   Do not install any fixture assembly closer than 6 inches from any curtain  or similar  combustible material     To prevent electrical shock  turn off electricity at fuse box before installing the track  or adding to or changing the configuration of the track     Instructions for grounding per instruction sheet of the feed in kit used must be  followed  Failure to do so may result in a hazardous condition     Use  12 ga  AWG solid wire only  not stranded wire  for supply to track    Observe polarity  white supply lead  neutral  to contact marked    NEUT    on screw  terminal connectors    Do not exceed 4 feet between mounting points     Do not attempt to energize anything other than track lighting fixtures on the track   To reduce the risk of fire and electrical shock  do not attempt to connect power tools   extension cords  appliances and the like to the track     SAVE THESE INSTRUCTIONS    l i Cs l TOI j    R FALL RIVER  MASSACHUSETTS 02720    I i a     MONTREAL  QUEBEC  CANADA       INSTRUCTION SHEET NO     1  26600    A0397 Page 2 of 4    MOUNTING PROSPEC    TRACK    There are three methods of mounting the track to a surface  Fig A  B  amp  C    1  Direct mounting 
3.  Fig A     Mark centerline for track location    Add mounting holes to the track    n the center of the track drill the appropriate number of mounting  holes  The holes should be 3 16  in diameter  Recommended  two  holes per 4  track  three holes per 8  track  and four per 12    track   ever use one mounting hole per track length  Additional holes may  be added for more support  The holes should be evenly spaced along  he track length   CLEAN ALL METAL AND PLASTIC CHIPS FROM THE TRACK    Mount the track to the structure using  6 flat or round head screws   and plastic washers  Use a screw appropriate for the material  For  example  use a  6 flat head wood screw if you are mounting into a  wood beam  Plastic washers are included  screws are not included     2  Mounting Straps  Fig  B     e Mark centerline for track location    e Remove the Dead End from one end of the track and save    e Slide the mounting straps into the groove in the side of the track  An  equal number of straps should be on each side of the track  Always  use more then one strap per side    e Wrap the straps around the building structure or nail the straps to the  structure    e Push Dead End into the track at the end of the track run     3  Hanger Clips  sold separately Cat  26090 set of 4   Fig  C     e Slide or snap the hanger clips onto the track    e Assemble the screws and nuts onto the mounting clips    e Recommended  two clips per 4  track  three clips per 8  track  and four  per 12  track  Always 
4. READ AND UNDERSTAND THESE INSTRUCTIONS BEFORE INSTALLING TRACK INSTRUCTION SHEET NO   This fixture is intended for installation in accordance with the National Electrical Code and local or Federal code  specifications  To assure full compliance with codes and regulations  check with your local electrical inspector i a 26600  before installation  To prevent electric shock  turn off electricity at fuse box before proceeding       Save these instructions for maintenance reference A0397 Page 1 of 4  and refer to them when additions to or changes in the track configuration are made        Installation Instructions for ProSpec    Track Lighting    Recessed Feed Track and Plain Track Units              ProSpec    track lighting is designed to support and energize ProSpec    Lytespots   which can be  attached anywhere along the track  It is a four conductor system  continuously grounded through   out  to be supplied by two single 120V  20 amp  60Hz branch circuits  It is not intended for use with  a power cord or convenience receptacles  ProSpec    is listed by Underwriters Laboratories  Inc  It  may only be used with electrical fittings identified for use with ProSpec    track     IMPORTANT SAFETY INSTRUCTIONS    Read all Track  Connector  Feed in Kits  and Accessory Instruction Sheets before  installing any ProSpec    Track item  When installing or using this track system  basic  safety precautions should be followed     Read all instructions before installing the track system    e
5. ns for Recessed ProSpec    Track INSTRUCTION SHEET NO     Power Feed to Track   S    26600    A0397 Page 3 of 4       DIRECT POWER FEED TO  FEED  TRACK    Use solid 12 ga  copper wire when feeding the track  The feed track accepts  two separate 120 V  60 Hz branch circuits  Each circuit must not exceed the Electrical  20 amp capacity of the track system  Connector    FEED FROM ABOVE TRACK  Fig E   Knock out  e Remove Bottom cover and save     e Remove Knockout in Top Plate   e Remove Top Plate from Track ae  e Secure electrical connector  by others  3 s size recommended  to Top i f ae 5 Fead Mank    Plate using the Nut provided  Position connector locking screws such  that the screws will be hidden behind the track width    e Attach Top Plate to track    e Pass wires through connector and secure the cable or conduit to the  connector  The track must not support the cable  Use separate support  for securing the cable to the building structure      e Secure the track to the ceiling  see mounting on previous page   Use 12 ga  solid copper wire for feed   e Form the wires in the Feed track to the connector terminals conectionsiineluding grduna     see FIG  F   Cut and strip each wire  Attach wires to the screw SO te  terminals  Wires must be tightly held in the screw terminals  Neutral pce Grau  wires must be attached to screw terminals marked  NEUT     Ground Neutral 2 Neutral 1  wire must be attached to the green ground screw   e Snap Bottom Cover into the track              Ne
6. use more then one clip per track length   Additional clips may be added for more support  The clips should be  evenly spaced along the track length    e Tighten the clip on the track by tightening the screw and nut  Pass  cable through hole in hanger clip  Level track and tie cable to support  the track                 STRAIGHT CONTINUOUS RUN OF TRACK    e Remove the Dead End from one end of the track that will be joined     e Slide the spline  1 2 its total length  into the side channels of the track  unit    e Install the spline screws into the spline and tighten    e Use an Invisible Coupler  26049WH  to join two tracks together  mechanically and electrically  Fig  D   Power cannot be fed into the  coupler  See the instructions provided with the coupler prior to   installation    e Use an In Line connector  26654WH  to feed power between two track  units  Additional splines are not required when using the In line  Connector  The connector comes with the splines attached  Fig  D     See instruction sheet provided with the In line connector prior to  installation    Tighten all spline screws    e Push Dead End into the track at the end of the track run                         Recessed ProSpec    Track Mounting Methods       FIG A             1 7 8  jee    Structural Mounting Material     6 Screw appropriate to Mounting Material    Plastic Washer                                        FIG  C    Hanger Cli  Nut 9      Screw   L                 Track Unit             Instructio
7. utral    Terminals  Power    Terminals       Two wires may be  attached to one  screw terminal           FEEDING ALONG THE TRACK LENGTH  Fig  G     A floating splice box may be used to feed the  Feed Track  from along the  tracks length  The floating splice box can be mounted anywhere on the track  up to 4  from the end of the track  The wires are passed along the top of the  track and into the feed end of the track  The floating splice box may  only be used when there is accessibility to the splice box after the  installation is complete    Floating Splice Box  Cat  no  26660  sold separately  See instructions  supplied with 26660 for complete installation details     Floating Splice Box    Feed Track Unit                INSTRUCTION SHEET NO     1  26600    A0397 Page 4 of 4    POWER CONTINUITY FROM  A STRAIGHT RUN OF TRACK    This can be accomplished by using Feed Tracks coupler together  by using  Feed Track with a power extension connector  or by using Plain Track with  multiple Power Extensions  The Power Extension Connector is sold  separately  CAT  NO  26646WH   See instructions with the power extension  for installation details     NOTE  THIS TRACK SYSTEM IS NOT POLARIZED  Connectors can be  installed into both sides of the Plain Track and in any orientation  There is  no key that will prevent insertion of the connectors  Connectors cannot be  attached to the feed side of the Feed Track  Electrical polarity is maintained  by proper wiring of the circuits   See Fig F  
    