1. MD Coffer 2 x 4 Recessed or Surface MDCGWSVA2SB4SB Page 1 of 4 Features e Four integral lighting functions indirect ambient direct reading examination and optional night light e Precise light control for glare free patient environment e Installs as a one piece unit e Recessed or surface mounted to ceiling which eliminates damage to fixture from hospital equipment attached to bed e 6 7 8 deep e All lamps are shielded e All twin tube T5 lamps are accessible for relamping without tools e All ballasts accessible thru louver compartment e Optional low voltage electronic sequential switch mounted in fixture for ambient and reading light controlled with pillow speaker optional by others e Optional night light e Meets NYC Code requirements Chicago Plenum requirements available Multi Function Patient Lighting Indirect Ambient Light with Perforated Mesh Shield Mounting Methods ea surface Ceiling 9 6 max mounting height from wall Accoustical tile Fa Exposed T grid ceiling ata y others Secure fixture Acoustical tile 4 places Wall angle by others or T bar by others from wall ceiling height 6 07 9 6 max Dimensions Tepe we espe i 175 AUO Y Y Y T Y WH U 1 Reading light with low iridescence anodized semi specular aluminum reflector 2 Perforated mesh lamp shield with white acrylic overlay 3 Ambient light with flat white reflector f
2. e For Grid lay in Floating Extruded Thickness 2 Lamps Multi function Or Surface Aluminum Door Overlay Total Patient Light Mounted Frame standard Ballast Type Ballast Type with Perforated VI 125 Thick Ambient Reading Examination Mesh Shield Pattern 12 lt 20THD lt 10THD lt 20THD lt 10THD Acrylic Lens 1 2 Lamp Elec TT5 SB IB 1 3 Lamp Elec TT5 X3 13 40 Watt 2 2 Lamp Elec 115 SB IB 1 2 Lamp Elec TT5 PR 2 2 Lamp Elec TTS PR 40 Watt 40 Watt LOL Dimming TT5 PB z me 3 Instant Start Standard Se Pron San NOTE NOTE For TT5 UNV you must use IB Ballast For TTS UNV you must use IB Ballast Code Code Options Accessories Access Plates Top wiring access plate is shipped with fixture as standard When access plates are required in advance for wiring convenience specify separately Catalog Number ACP Drywall Kit Order Catalog Number FK92X4 Request Folio OA30 10 Rev A Electronic Sequential Switch Low Voltage Switch factory mounted in fix ture for ambient and reading light convenience controlled by pillow switch by others Suffix SW Individual Switching Low Voltage Switches mounted to patient s bed for use with manufacturer s control system such as Hill Rom Side Com Suffix DP 9 7 Watt Night Light Suffix PL Lamp not included Fusing Internal fast blow fusing Suffix GLR Internal slow blow fusing Suffix GMF Radio Interference Filter To order one RIF per fixture Suf
3. fix R To order one RIF per ballast Suffix B Germ Shield Order Catalog Number MD4CLGS24 Electrical Wiring Options Consult factory Specifications Materials Chassis parts are die formed 20 gauge steel Louver examination light aluminum post painted white acrylic Reading light low iridescence anodized 95 reflective semi specular reflector Ambient light flat white acrylic contoured steel reflector and perforated steel mesh shield with white acrylic overlay Finish Cavity examination reading ambient lights flat white acrylic interior minimum reflectance 86 Phosphate undercoating Chassis exterior post painted white baked polyester powder Louver examination light W flat white baked enamel 36 cell louver with a virgin acrylic overlay to enclose all lamps VA 095 nominal thickness prismatic virgin acrylic overlay VI 125 nominal thickness pattern 12 acrylic lens Electrical Thermally protected class P ballast C B M approved non PCB If K O is within 3 of ballast use wire suitable for at least 90 Specifications continued Labels B E W UL and ULc Listed This product may have a mercury containing lamp Manage in accord with Disposal Laws See www lamprecycle org Job Information Lightolier a Genlyte company Technical Information 978 657 7600 e Fax 978 658 0595 631 Airport Road Fall River MA 02720 e 508 679 8131 Fax 508 674 4710 We reserve the right to chan
4. ge details of design materials and finish 2007 a Genlyte company HPWIOLEFSOVT www lightolier com Section 8 Folio R40 21 Rev A a
5. lat white interior 4 Examination light with 36 6x6 cell flat white baked enamel louver 5 Prismatic virgin acrylic overlay 6 Twin tube T5 lamps 6 7 Optional night light 7 9 watt PL 8 Ballast compartment accessible by opening louver and reflector Mounting holes 8 2 x 3 access plate with 2 7 8 dia K 0 s Examination Tabs for wire supports 4 places 2 x 3 access plate with 2 7 8 dia K 0 s Ambient Reading Job Name Cat No Lamp s Volts Ballast Lightolier a Genlyte company www lightolier com Technical Information 978 657 7600 Fax 978 658 0595 631 Airport Road Fall River MA 02720 e 508 679 8131 Fax 508 674 4710 We reserve the right to change details of design materials and finish 2007 a Genlyte company Section 8 Folio R40 21 Rev A HWIOLEFSOVT a MD Coffer 2 x 4 Recessed or Surface MDCGWSVA2SB4SB Page 2 of 4 Multi Function Patient Lighting Indirect Ambient Light with Perforated Mesh Shield Ambient Light Indirect illumination from twin tube T5 shielded by perforated mesh shield with white acrylic overlay No direct glare to patient No direct glare to patient s visitor No direct glare to adjacent patients 12 Wall FOOTCANDLES ON BED Reading Light Eliminates reflected glare from reading material over shoulder illumination No direct glare to patient or visitors Controls light directly onto patient s bed 6 12 I
6. llumination atthe reading task ranges Lighted 45 50 footcandles 12 Wall Bed FOOTCANDLES ON BED Examination Light Excellent color rendition Wired for independent switching 1 or 2 circuit Optional louver or lens frame Concealed hinging and latching 5 q 9 iz Wall Bed FOOTCANDLES ON BED Totals of ambient reading and examination lights Numbers in parenthesis are total footcandle level of ambient and reading lights only a MDs Coffer 2 x 4 Recessed or Surface MDCGWSVA2SB4SB Page 3 of 4 Multi Function Patient Lighting Indirect Ambient Light with Perforated Mesh Shield Night Light Optional Indirect 9 or 7 watt PL lamp shielded by perforated mesh gy with internal white acrylic overlay 3 No glare to any patient Wired for independent switching Wall FOOTCANDLES ON BED Options Pillow speaker by others PL9 or PL7 Night Light Suffix PL Lamps not included Sequential Switch Suffix SW MD Coffer s optional low voltage 1 3 volts sequential switch mounted in the fixture is listed in compliance with UL 544 for medical and dental equipment Two red wires coming from the fixture can be wired to a wall receptacle by others for use with that manufacturer s pillow speaker The pillow speaker is used to control the television call the nurse and control the lighting To control the lighting it should be specified to have a normally open contact switch Pressing this switch on
7. the pillow speaker the first time turns the ambient light on pressed a second time turns the reading light on and the ambient light off pressed a third time turns both the ambient and reading lights on pressed a fourth time turns both lights off Pressing the button again repeats the cycle Should the patient s bed be rolled away from the wall the pillow speaker will simply pull free from the wall receptacle avoiding any damage TAMPER RESISTANT GERM SHIELD Germ Shield Ideal for psychiatric wards and germ free environments Fits lay in grid ceiling systems with 15 16 maximum ceiling tee face The heavy duty welded extruded aluminum frame with clear 1 8 thick polycarbonate lens is fixture to ceiling system sealed with a heavy duty gasket Request Folio R40 15 REV A Tamper Resistant Germ Shield Ballast Compartment accessible by opening Louver and reflector Page 4 of 4 ORDERING INFORMATION Explanation of Catalog Number Example MDCGWSVA2SB4SB120SW MD Coffer 2 x 4 Recessed or Surface MDCGWSVA2SB4SB Multi Function Patient Lighting Indirect Ambient Light with Perforated Mesh Shield ii DI oa baa a L MD C Louver Lamp Lamp Voltage Options Indirect Type Lens Frame Overlay Lens Quantity Quantity 120 or 277 Add appropriate Direct Same Unit WS White Louver VA Virgin Acrylic Ambient 3 3Lamp Suffix to Catalog Recessed or May Be Used RF Regressed 095 Nominal Reading 4 4 Lamp No i e GLR Surfac