Lightolier EC1-2 User's Manual
Contents
1. 6 through wires D Dual Switch T Tandem Switch E Emergency 4 8 243 84cm Continuous Row Mounted ECS Systems 1 Determine run length 2 2 lamp See Chart on See Chart on P Parabolic 4 open top Page 3 Page 3 Louver 8 5 2 lamp slotted top reflector Ordering Instructions End Cap ECS Systems 9 1 Order Master 4 121 92cm or 8 243 84cm ECS Module 2 Order Power Feed End Set 3 4 5 6 ECS Sensor Sample Runs Eo 4 Run 4 121 92cm Master Module with Single Sensor End Set gt 8 Run 8 243 84cm Master Module and standard Energos End Set A oo n 8 Run 8 243 84cm Master Module and Dual Sensor End Set Ca en ee gt 12 Run 8 243 84cm Master Module 4 121 92cm Slave Module Dual sensor End Set and Intermediate Cable Assembly a a ae ee i 16 Run 8 243 84cm Master Module 8 243 84cm Slave Module standard Energos End Set and Intermediate Cable Assembly a Se a 16 Run 8 243 84cm Master Module 8 243 84cm Slave Module Single sensor End Set and Intermediate Cable Assembly 16 Run 8 243 84cm Master Module 8 243 84cm Slave Module Single sensor End Set and Intermediate Cable Assembly Notes 1 See page 1 of Specification Sheet or consult Application Guide for the definition of Serial Row Linking SRL 2 Consult the matching EG specification sheet for Luminaire related specifications i e Housing materials shielding mounting d
2. Program Program Program Program Program Program Program Program Program Program Program Program Program Program Program Program Program Program Program Program Program 631 Airport Road Fall River MA 02720 e 508 679 8131 Fax 508 674 4710 We reserve the right to change details of design materials and finish www lightolier com 2008 Philips Group C0808 PHILIPS
3. a smaller area of detection See chart and diagram for additional information Coverage Diameter 16 0 14 5 12 10 Sensor Height AFF A D EEIEIEE SSS SSS SSS SOS Besos esas ec ee slate tehatetghatete lt 7 QO Q LQ QQQ 9 UDO DALY YY YY YY YY YG GG OOOO OOO MUM MMMM MMMM MM MUMMY MMM VV MMMM Me MMMM MMMM MMMM MMMM MMM MMMM MMMM MMMM MMMM MMMM MMMM ERROR RRR ION Energos Occupancy Sensor Coverage Zone Chart Task Diameter 8 0 243 84cm 7 3 214 12cm 6 5 184 15cm 5 7 154 18cm Broadcast Diameter 16 0 487 68cm 14 5 427 99cm 12 10 391 16cm 11 3 336 04cm Height of Sensor 10 0 304 80cm 9 0 274 32cm 8 0 243 84cm 7 0 213 36cm Job Information Job Name Cat No 631 Airport Road Fall River MA 02720 e 508 679 8131 Fax 508 674 4710 We reserve the right to change details of design materials and finish www lightolier com 2008 Philips Group C0808 PHILIPS LIGHTOLIER Page 2 of 3 Control Ordering Information Ballast Series a Family Lamping amp Distribution Lamp Shielding Lighting Systems EC1 2 Energos Control System 2 Light T8 per 4 121 92cm Nominal Louver Finish Length Voltage Options Blank 121 92cm 6 120 Vac Master 7 277 Vac Master 8 120 Vac Slave 9 277 Vac Slave A Aluminum W White 4 4 through wires 5 5 through wires 6
4. C T8 28 2725 D T8 30 2850 E T8 30 2850 F T8 30 2850 G T8 J2 3000 H T8 32 3000 T8 32 3000 J T8 J2 3100 K T8 32 3100 L T8 32 3150 Lamp IES Output System System System Color lumens Input Efficacy Lamp Life Kelvin Watts lum watt Hours 3000 2199 20 0 96 74 24000 3500 2199 20 0 96 74 24000 4100 2199 20 0 96 74 24000 3000 2299 21 5 94 12 24000 3500 2299 21 5 94 12 24000 4100 2299 21 5 94 12 24000 3000 2420 23 0 92 61 24000 3500 2420 23 0 92 61 24000 4100 2420 23 0 92 61 24000 3000 2501 23 0 95 70 30000 3500 2501 23 0 95 70 30000 4100 2541 23 0 97 24 30000 3000 2725 255 94 04 24000 3500 2125 25 5 94 04 24000 4100 2725 25 5 94 04 24000 3000 2850 215 91 20 24000 3500 2850 215 91 20 24000 4100 2850 27 5 91 20 24000 3000 3000 29 0 91 03 24000 3500 3000 29 0 91 03 24000 4100 3000 29 0 91 03 24000 3000 3100 29 0 94 07 24000 3500 3100 29 0 94 07 24000 4100 3150 29 0 95 59 24000 3000 2850 143 34 8 83 80 NA 3500 2850 143 34 8 83 80 NA 4100 2850 143 34 8 83 80 NA 22000 i S Average Rated Life Hrs A Lighting Systems EC1 2 Energos Control System 2 Light T8 per 4 121 92cm Nominal Louver Lamp Ordering Information Job Information 4 5 Hours Per Start Lamp Life Table using program start and instant start ballasts Rated Output 6 T Color K 3000 3500 4100 3000 3500 4100 3000 3500 4100 3000 3500 4100 Start Type Program Program Program Program Program Program
5. DIM 1 0 0 5 25 C Rating Ballast Factor Start Type THD Program lt 10 Program lt 10 Program lt 10 Ballast Lamp Rated E 0 THD Wattage Output lt 10 28 2725 lt 10 28 2725 lt 10 28 2725 lt 10 30 2850 lt 10 30 2850 lt 10 30 2850 lt 10 32 3000 lt 10 32 3000 lt 10 32 3000 lt 10 a2 3100 lt 10 32 3100 lt 10 32 3150 lt 10 28 2725 lt 10 28 2725 lt 10 28 2725 lt 10 30 2850 lt 10 30 2850 lt 10 30 2850 lt 10 32 3000 lt 10 32 3000 lt 10 32 3000 lt 10 32 3100 lt 10 32 3100 lt 10 32 3150 lt 10 32 2850 lt 10 32 2850 lt 10 32 2850 All data is per 1 lamp on a two lamp system at 277 VAC Data is based on Osram Sylvania specifications When ordering no lamps provided by Lightolier use lamp code Z Do not alter lumen values or ballast factor light losses when completing calculations using Energos IES files Files have already been adjusted The lumen value for the lamp within a Lighting Design program will be the IES Ouput value shown on this table The lamp life table demonstrates the effects of shortened cycle times with both program start and instant start ballasts The graph shows that instant ballasts are susceptible to shortened lamp life if short cycle periods of less than 3 hours are used For cycle periods of greater than 3 hours program start ballast are not required Lightolier is a Philips group brand Design Lamp Type Wattage ciinietis A T8 28 2725 B T8 28 2725
6. LIGHTOLIER Page 1 of 3 Lighting Systems EC1 2 Energos Control System 2 Light T8 per 4 121 92cm Nominal Louver S Feature Specifications Energos Control System For standard Energos fixtures consult appropriate EG spec sheets Feature Specifications Electrical Dedicated low voltage 24 VDC circuit controls the Energos Control Systems The line voltage circuits control all the standard ballast functions including A B switch ing Dimming and Emergency Battery Pack operations ai 2 Mid mounted 8 243 84cm sensor Mounting 1 End Cap Sensor Mounting ECS occupancy sensors are available in two variations e Mounted in the end cap e The middle of an 8 243 84cm module The ECS system control center is the Power Pack The Power Pack contained in each Master Module interrupts the circuits when parameters dictate The Power Pack can control up to 600 watts 120 VAC and 1300 watts 277 VAC A maximum of 10 sensors can be used on a single Power Pack There is no limitation to the number of Power Packs that can be daisy chained to a single ECS circuit Emergency battery packs can be used in conjunction with ECS for emergency egress lighting since all listed packs operate for a minimum of 90 minutes EM Packs can be used as momentary lighting for emergency circuit for power transitions and smaller packs are recommended for this purpose Dimming ballasts can be used in conjunction w
7. imensions and photometry Job Information Order a minimum of one master per run Please see Application Guide for master requirements on runs that exceed 16 487 68cm Order the required remaining Master and Slave modules to complete the run Order Power Feed End Set Order one CABLE ASSEMBLY per MODULE minus one per run Order additional Single Cable amp Cord Sets for every Master Module in run ECS End Sets AL AL Single Sensor End Set EC1SE36W Dual Sensor End Set EC1DE36 W AL dL Dual Sensor SRL Single Cable amp Power Cord EGCC36 Single Sensor SRL End Set EC1SR36W End Set EC1DR36 W Standard End SRL Standard Set EG1EC36W End Set EC1ER36W 631 Airport Road Fall River MA 02720 e 508 679 8131 Fax 508 674 4710 We reserve the right to change details of design materials and finish www lightolier com 2008 Philips Group C0808 Lightolier is a Philips group brand PHILIPS LIGHTOLIER Page 3 of 3 Design Lamp Type Ballast Ordering Information D T8 0 71 E T8 0 88 H Dim T8 1 00 05 Lamp and Ballast System Data Lamp Type Ballast pesign T8 or T5 Factor BF DA T8 0 71 DB T8 0 71 DC T8 0 71 DD T8 0 71 DE T8 0 71 DF T8 0 71 DG T8 0 71 DH T8 0 71 DI T8 0 71 DJ T8 0 71 DK T8 0 71 DL T8 0 71 EA T8 0 88 EB T8 0 88 EC T8 0 88 ED T8 0 88 EE T8 0 88 EF T8 0 88 EG T8 0 88 EH T8 0 88 EI T8 0 88 EJ T8 0 88 EK T8 0 88 EL T8 0 88 HG T8 DIM 1 0 0 5 HH T8 DIM T0705 HI T8
8. ith ECS However the control system will only perform ON or OFF operations and will not affect the level of dim ming set by the dimming ballasts Factory installed ballast disconnect allows the ballast to be disconnected from and reconnected to incoming power under load without turning the entire circuit off Serial Row Linking SRL provides multiple continuous row communication For every run that SRL is required order the appropriate SRL end set from page 2 of this Specification Sheet Consult Energos Application Guide for more detailed definitions and examples Mountings Cable suspension distances are on 48 121 92cm and 96 243 84cm centers and consist of a 4 1 2 11 43cm diameter canopy finished white enamel A 1 16 0 16cm diameter stainless steel aircraft cable accomplishes suspension and is adjustable from 12 30 48cm to 36 91 44cm Power feeds are 18 gauge silver braided cord with clear jacket Lightolier is a Philips group brand Occupancy Sensors e Time delay is factory pre set to 30 minutes e Time delay can be field adjusted from 30 minutes to a minimum of 30 seconds e Daylight hold off is factory pre set to 120 ft candles 1291 67m candles e Daylight hold off is field adjustable from 120 ft candles 1291 67m candles down to 10 ft candles 107 64m candles e Sensors are designed for a detection area sensitivity diameter of 16 487 68cm when suspended 10 304 80cm AFF Lowering the sensor produces
Download Pdf Manuals
Related Search
Related Contents
User Manual - B&H Photo Video Digital Cameras, Photography PT50 alarmplus user manual Stamina Products , Inc Fitness Equipment 55-1510 User's Manual Panasonic MC-UG509 Vacuum Cleaner User Manual SYBA SY-AUD23018 loudspeaker 取扱説明書 - ソニー製品情報 Dell Brocade 6505 Quick Start Manual BD Diesel Performance Automobile Accessories 1054745 User's Manual Copyright © All rights reserved.