Home
Lightolier CD7-4 User's Manual
Contents
1. 631 Airport Road Fall River MA 02720 e 508 679 8131 e Fax 508 674 4710 We reserve the right to change details of design materials and finish www lightolier com 2008 Philips Group C1008 Lightolier is a Philips group brand PHILIPS
2. Road Fall River MA 02720 e 508 679 8131 e Fax 508 674 4710 We reserve the right to change details of design materials and finish www lightolier com 2008 Philips Group C1008 PHILIPS LIGHTOLIER Lighting Systems CD7 4 Page 2 of 2 Lowprofile Direct Lens 1 Light T8 Per 4 Foot Section Performance and Quick Calculator CANDLEPOWER CURVE CANDLEPOWER COEFFICIENTS OF UTILIZATION 180 175 165 155 145 135 ZONE 0 22 45 67 90 x DEG EFFECTIVE CEILING CAVITY REFLECTANCE 180 0 0 0 0 0 175 0 0 0 0 0 80 70 50 165 0 0 0 0 0 WALL REFLECTANCE 155 0 0 0 0 0 50 30 10 50 30 10 50 30 10 145 0 0 0 0 0 0 64 64 64 63 63 63 60 60 60 13 O 0 0 O Q o 1 58 56 55 57 55 54 55 53 52 a a a 2 53 51 48 52 50 48 50 48 47 105 0 0 0 0 0 amp 3 49 46 43 48 45 43 47 44 42 95 0 0 0 0 0 4 45 41 38 44 41 38143 40 38 90 0 0 0 0 0 a 5 4 37 34 40 37 34 39 36 34 85 7 20 16 17 12 6 38 34 31 37 34 31 36 33 31 75 46 56 33 52 42 S 7 35 31 28 34 31 28 34 30 28 65 6 99 73 84 53 Z 8 32 28 25 32 28 25 31 28 25 55 169 204 184 166 116 9 29 25 23 29 25 23 28 25 23 a A T a ane a 3 aal a 10 26 22 19 25 22 19 25 22 19 9 REPORT NO LRL 282 5E 25 674 682 691 698 697 207e FLOOR CAVITY REFLECTANCE LAMP 1 32W T8 15 743 744 750 755 750 LUMENS 2900 af 5 752 750 733 72 782 pas a TOTS TASE iS ite ZONAL LUMEN SUMMARY ZONE LUMENS LAMP LUMINAIRE Fixture Lengths amp Mounting Locations 0 30 1564 53 9 10
3. 0 0 90 180 0 0 0 0 0 45 1 2 1 15 57cm gt 6 15 24cm gt e 37 93 98cm 0 180 1564 53 9 100 0 LLLLLLLLLLLLLLLS SPACING RATIOS PARALLEL 1 2 PERPENDICULAR 1 7 ROOM SURFACE REFLECTANCES 80 CEILING 50 WALLS 20 FLOOR _ lt 49 124 46cm gt lt 49 124 46cm gt 120 3200 LUMENS PER LAMP 4 Foot Cable and Stem Wall RCR 1 Rm Width 10xMtg Ht above work plane 100 RCR 5 Rm Width 2xMtg Ht above work plane RCR 10 Rm Width Mtg Ht above work plane 94 1 2 240 03cm _ gt INITIAL FOOTCANDLES 10 20 30 40 50 60 70 80 90 i AREA PER FIXTURE IN SQUARE FEET 8 248 926cm gt 3 a 5 6 7 8 9 f i i i f 8 Foot Cable and Stem CENTER TO CENTER DISTANCE OF FIXTURES IN FEET ABOVE DATA FOR 1LT 40 W 49 UNITS FOR 2LT 49 UNITS FC X 17 Sample Run 94 1 2 240 03cm gt 49 124 46cm _94 1 2 240 03cm T 8 Foot Fixture 4 Foot Fixture 8 Foot Fixture 20 5 622 30cm Mounting Details A A 24 24 4 1 2 60 96cm 60 96cm 15 43cm k lt 12 30 48em gt yy yy a 3 1 4 8 26cm 3 1 4 8 26cm 2 3 5 8 9 21cm 9 22 86cm gt 9 22 86m gt 9 22 860 F reals Stem Cable Surface Wall Job information tee
4. LIGHTOLIER Page 1 of 2 Lighting Systems CD7 4 Lowprofile Direct Lens 1 Light T8 Per 4 Foot Section 9 22 86cm A 1 2 3 1 4 8 26cm 3 E 5 12 70m Half Scale Ordering Information Style Type Mounting Length Total Lamps Color Ballast amp Voltage cD7 2 WH 2 Direct Lens 1 Surface 4 4 foot 1 1 Lamp T8 White E81 T8 Electronic 120V 2 Cable 8 8 foot per fixture E82 T8 Electronic 277V 3 Stem fixture HD1 T8 Electronic PowerSpec 4 Wall 2 2 Lamp T8 HDF Dimming 120V per fixture HD2 T8 Electronic PowerSpec 8 fixture HDF Dimming 277V Complete ordering instructions below Features 1 Housing Extruded aluminum Die cast end cap mechanically attached with no exposed fasteners Concealed access holes in end plate for through wiring 2 Lamping One T8 32 watt fluorescent lamp as specfied Provided by others 3 Reflector Accurate parabolic shaped die formed semi specular anodized aluminum reflector with 36 shielding crosswise 4 Lens Extruded 100 of acrylic clear debossed prismatic lens Electrical Specify 120 volt or 277 volt 3 conductor 18 gauge wire Color coded quick connectors allow ease of connection for joiner modules For special circuiting consult factory Rapid start HPF class P thermally protected PowerSpec HDF dimming ballast is available Factory installed ballast disconnect allows the ballast o be disconnected f
5. rom and reconnected to incoming power under load with out urning the entire circuit off Mountings Cable Suspension not shown 1 1 2 3 81cm and 4 1 2 11 43cm diameter lat canopy finished enamel white 1 16 0 16cm diameter stainless steel aircraft cable adjustable up to 36 91 44cm adjustable cable gripper Stem Mounting not shown 4 1 2 11 43cm diameter flat canopy 1 2 1 27cm diameter rigid mounted stem White finish Can be cut to length on job Self aligning swivel provides adjustability up to 42 of slopes Surface amp Wall Mounting not shown consult factory for availability Finish Powder coated baked white enamel Custom colors available consult factory Lightolier is a Philips group brand M71 T8 Electronic Dimming Ballast 120V M72 T8 Electronic Dimming Ballast 277V For all fixtures represented in this family please refer to the brochure and or additional specification sheets Options and Accessories Emergency batteries available Ordering Instructions Individual Fixtures 1 Order number of FIXTURES fixture comes complete with end caps mounting hardware and power feeds Continuous Rows 1 Determine run length 2 Order the appropriate number of FIXTURES for the complete run Fixtures can be bolted together and through wired to complete long runs Labels UL cUL and B E W Job Information Job Name Cat No Lamp s Notes 631 Airport
Download Pdf Manuals
Related Search
Related Contents
Desktop Cooler & Filter Water Dispenser USER'S MANUAL GE 106820 User's Manual Funkrauchwarnmelder Radio Smoke Detector User Manual Intelligence IR high speed dome camera FlexScan terrain sec et plan. - Campingcar T OPERATING INSTRUCTIONS DTC5U3I5U3-N/2031303 Manuel d`utilisation du vélo Copyright © All rights reserved.
Failed to retrieve file