1. Finished Ceiling Finished Ceiling lrimless Aperture Frame l nee X Sheet Rock Spackle Figure 8 631 Airport Road Fall River MA 02720 e 508 679 8131 e Fax 508 674 4710 We reserve the right to change details of design materials and finish www lightolier com 2008 Philips Group B0908 Lightolier is a Philips group brand PHILIPS LIGHTOLIEI Calculite IS PB Page 6 of 11 Instruction Sheet for Assembly and Installation of ProSpec Linear Series B INSTALL APERTURE FRAME Step 1 Aperture Frame Installation for All PB Fixtures A MR16 AR70 and AR111 a Insert Plug Connectors from sockets into receptacles on inside wall of housing b Connectors are polarized and therefore may only be inserted in one direction c Make sure connectors snap firmly into space Fig 9 11 Receptacle Connector EKT MountingScrew Receptacle Connector SSocket S A Plug Connector MR16 Figure 9 Figure 10 Receptacle Connector Housing Plug Connector or Lamp Connectors A Ce er Lamp By Others Cy Media Cartridge AR111 Figure 11 631 Airport Road Fall River MA 02720 508 679 8131 e Fax 508 674 4710 We reserve the right to change details of design materials and finish www lightolier com 2008 Philips Group B0908 Lightolier is a Philips group brand PHILIPS LIGHTOLIEI Calculite IS PB Page 7 of 11 Instruction Sheet for Assembly
2. Step 4 Reinsert Reflector Spring Tabs into Spring Slots on track head and same way it was removed in step 2 T4 T6 Spring Slot Closed Lens Spring Reflector Spring Spring Slot Spring Tab Spring Tab Figure 16 Lens Holding Tab Figure 17 Luminaires Compatible Reflectors Description Cat No Description Prospec Linear 1L MHT4RS T4 Spot Prospec Linear 2L MHT4RNF T4 Narrow Flood Prospec Linear 3L MHT4RF T4 Flood Prospec Linear 4L Prospec Linear 1L MHT6RS T6 Spot Prospec Linear 2L MHT6RNF T6 Narrow Flood Prospec Linear 3L MHT6RF T6 Flood PB4T6 Prospec Linear 4L 631 Airport Road Fall River MA 02720 508 679 8131 Fax 508 674 4710 We reserve the right to change details of design materials and finish www lightolier com 2008 Philips Group B0908 Lightolier is a Philips group brand PHILIPS LIGHTOLIEI Calculite IS PB Page 9 of 11 Instruction Sheet for Assembly and Installation of ProSpec Linear Series B INSTALL LAMP AND ACCESSORIES Note Only PAR30 short neck will fit PAR30 incandescent series Step 1 Remove Media Cartridge with counter clockwise motion Step 2 Install Lamp A T4and T5 Lamp Installation a Install T4 and T6 into socket Fig 19 amp 20 b Reinsert Lens by placing it behind Closed Lens Spring then position it into opening Slide Lens Spring into closed position Fig 21 c Add up to a maximum of two accessories to Media Cartridge
3. member 1 2 1 27cm to overhead D Luminaire center to side building member 3 91 44cm to side of building member 631 Airport Road Fall River MA 02720 e 508 679 8131 e Fax 508 674 4710 We reserve the right to change details of design materials and finish www lightolier com 2008 Philips Group B0908 Lightolier is a Philips group brand PHILIPS LIGHTOLIEI Calculite IS PB Page 4 of 11 Instruction Sheet for Assembly and Installation of ProSpec Linear Series B FRAME IN AND WIRE Step 1 Install Housing using Adjustable Mounting Brackets A Fixture must be secured to structural ceiling members If no ceiling access available fixtures must be installed before ceiling material With Mounting Bar Lightolier Cat No 1951 use rectangular slots Fig 1 With 1 2 1 27cm EMT by others Fig 2 _ With 3 4 1 91cm or 1 1 2 3 81cm Channel by others Fig 3 For Suspended T Bar Ceilings use Lightolier Cat No 1956 to secure 1951 Mounting Bars to ceiling runners Fig 4 F To install with hanging wires by others consult installation from hanging wire manufacturer Adjustable Mounting Bracket m Oo W ae Mounting Bar 1 2 1 27cm Order Separately 1951 EMT By Others 3 4 1 91cm or Screw Screw Screw 1 1 2 3 81cm Channel By Others Figure 1 Figure 2 Figure 3 Anchor Cli Mounting Bar Order e 1956 Order Separately 1951 A a Figure 4 Step 2 Conn
4. 7 78cm PB2P38 H38 35 56cm 17 78cm PB3P38 H38 53 34cm 17 78cm PB4P38 H38 71 12cm 17 78cm 15 56cm 15 56cm 33 02cm 15 56cm 49 53cm 15 56cm 66 04cm 15 56cm 15 56cm 15 56cm 33 02cm 15 56cm 49 53cm 15 56cm 66 04cm 15 56cm 15 56cm 15 56cm 33 02cm 15 56cm PB31470 1 2 49 53cm 15 56cm PB41470 66 04cm 15 56cm PB11639 1 8 18 10cm 18 10cm PB21639 38 10cm 18 10cm PB31639 1 2 57 15cm 18 10cm PB41639 76 20cm 18 10cm PB11670 7 1 8 18 10cm 18 10cm PB21670 15 38 10cm 18 10cm PB31670 22 1 2 57 15cm 18 10cm PB41670 30 76 20cm 18 10cm CAUTION Turn power off before lamping fixture Wait until fixture is cool before touching 631 Airport Road Fall River MA 02720 e 508 679 8131 Fax 508 674 4710 We reserve the right to change details of design materials and finish www lightolier com 2008 Philips Group B0908 Lightolier is a Philips group brand PHILIPS J MJ G2 G2 G2 G2 NINININI 07 07 07 91 91 07 01 N LIGHTOLIEI Calculite IS PB Page 11 of 11 Instruction Sheet for Assembly and Installation of ProSpec Linear Series B ADJUSTING AND LOCKING OF AIMING ANGLE Insert 7 64 allen key into c
5. LIGHTOLIEI Calculite IS PB Page 1 of 11 Instruction Sheet for Assembly and Installation of ProSpec Linear Series B READ AND UNDERSTAND THESE INSTRUCTIONS BEFORE PROCEEDING RETAIN THESE INSTRUCTIONS FOR MAINTENANCE REFERENCE This fixture is intended for installation in accordance with the National Electrical Code and local regulations To assure full compliance with local codes and regulations check with your local electrical inspector before installation To prevent electrical shock turn off electricity at electrical panel before proceeding DO NOT INSTALL THIS SYSTEM IN A WET LOCATION CONTRACTOR IS RESPONSIBLE FOR ADEQUATELY REINFORCING CEILING TO SUPPORT FIXTURE WEIGHT Adjustable Mounting Bracket Housing Flanged Trimless 631 Airport Road Fall River MA 02720 508 679 8131 e Fax 508 674 4710 We reserve the right to change details of design materials and finish www lightolier com 2008 Philips Group B0908 Lightolier is a Philips group brand PHILIPS LIGHTOLIEI Calculite IS PB Page 2 of 11 Instruction Sheet for Assembly and Installation of ProSpec Linear Series B Warning for All Fixtures Use only aperture frames and accessories provided by Lightolier Inc Use of other manufacturers aperture frames and accessories voids the Underwriters Laboratories Listing and could constitute a fir
6. and Installation of ProSpec Linear Series B INSTALL APERTURE FRAME CONT D B PAR30 PAR38 a Insert Lampholder into holes in Frame Yokes b Make sure socket springs engage slots in yoke Fig 12 C T4and T6 a Insert Plug Connectors from sockets into Receptacles on inside wall of housing b Connectors are polarized and therefore may only be inserted in one direction c Make sure connectors are snapped firmly into place Fig 13 Step 2 A Hook tortiontite Springs into slots of housing B Push Aperture Frame upward Fig 14 a Holder yee Slots Media Cartridge PAR30 PAR38 Figure 12 Figure 13 Tortiontite Springs Housing Slot Apperture Frame Figure 14 631 Airport Road Fall River MA 02720 508 679 8131 e Fax 508 674 4710 We reserve the right to change details of design materials and finish www lightolier com 2008 Philips Group B0908 Lightolier is a Philips group brand PHILIPS LIGHTOLIEI Calculite IS PB Page 8 of 11 Instruction Sheet for Assembly and Installation of ProSpec Linear Series B T4 AND T6 REFLECTORS INSTALLATION Note For any PB fixtures other than T4 and T6 skip to page 9 Install Lamp and Accessories Step 1 Support Lens and slide only the most convenient Lens Spring into open position Step 2 Depressing spring until Spring Tabs and removed from Spring Slots Fig 16 Step 3 Align Reflector Slot with the Lens Holding Tab and install Reflector Fig 17
7. ap screw and turn counter clockwise to unlock head and gimbel ring assembly Aim beam angle of lamp towards desired direction and turn cap screw clockwise to lock Head and gimbel ring assembly Widthwise Locking Insert allen key into opening of lever and gently move allen key in a counter clockwise arc to unlock lengthwise aiming direction Aim beam angle towards desired direction and gently move lever in clockwise direction to lock aiming angle Lengthwise Locking 631 Airport Road Fall River MA 02720 e 508 679 8131 Fax 508 674 4710 We reserve the right to change details of design materials and finish www lightolier com 2008 Philips Group B0908 Lightolier is a Philips group brand PHILIPS
8. by removing Retaining Ring inside Media Cartridge d Install Media Cartridge by aligning open slots of Media Cartridge to Holding Springs and turn Cartridge clockwise Closed Lens Spring ns l Holding Tab oe 5 Ii s Figure 18 Socket T Socket T4 Lamp T6 Lamp Figure 19 Figure 20 Holding Spring Figure 21 B Other PB Lamp Fixtures a Install lamp per fixture markings b Install one accessories into media cartridge and secure with spring c For MR16 use glass accessory d Install Media Cartridge onto Adjustable Ring 631 Airport Road Fall River MA 02720 e 508 679 8131 e Fax 508 674 4710 We reserve the right to change details of design materials and finish www lightolier com 2008 Philips Group B0908 Lightolier is a Philips group brand PHILIPS LIGHTOLIER Calculite IS PB Page 10 of 11 Instruction Sheet for Assembly and Installation of ProSpec Linear Series B Aperture Housing Opening Electrical Ratings Length Width Input Amps 12 70cm 12 70cm 25 40cm 12 70cm 38 10cm 12 70cm 50 80cm 12 70cm 12 70cm 12 70cm 25 40cm 12 70cm 38 10cm 12 70cm 50 80cm 12 70cm 17 78cm 17 78cm 35 56cm 17 78cm PB3A11 53 34cm 17 78cm PB4A11 71 12cm 17 78cm PB1P30 H30 15 24cm 15 24cm PB2P30 H30 30 48cm 15 24cm PB3P30 H30 45 72cm 15 24cm PB4P30 H30 60 96cm 15 24cm PB1P38 H38 17 78cm 1
9. e hazard Caution Risk of Fire Use proper lamp wattages with corresponding ballast wattages Check ballast module wattage label to confirm wattage Caution Risk of Burn Allow time for luminaire to cool before attempting to relamp or position Caution Risk of Burn and Electrical Shock Turn off power to Ballast Module before servicing All PowerArc Modular Ballasts are equipped with a power switch Depressing Dot on Switch is the ON position See IS 83B Note 1 Low voltage fixtures may produce audible sound when used with dimmers which maybe objectionable in acoustically critical areas 2 For HID Fixtures HID lamps require a warm up period of 5 10 minutes to reach full output Additionally when these lamps are extinguished they must cool for 5 15 minutes before they will relight Outage can be caused by momentary power failure substantial voltage reduction or cycle changes Warning for MR16 Fixtures Only Lamp manufacturers require the glass lamp guard be in place before energizing lamp and that great care must be taken that lamp is fully cooled before relamping Avoid finger marks on inside of lamp for they may cause short lamp life and possible breakage Warning for T4 and T6 Fixtures Only Risk of Fire Do not install insulation within 3 7 62cm of fixture sides or wiring compartment nor above fixture in such a man ner so as to entrap heat Caution If used improperly these lamps can cause serious skin burn and
10. ect Supply Leads White fixture lead to neutral white supply black fixture lead to hot supply lead bare fixture wire to supply ground Use wire nuts for all connections local hardware items Step 3 Place all electrical connections in J Box attached to side of fixture Step 4 Attach J Box Cover onto J Box attached to side of fixture 631 Airport Road Fall River MA 02720 508 679 8131 e Fax 508 674 4710 We reserve the right to change details of design materials and finish www lightolier com 2008 Philips Group B0908 Lightolier is a Philips group brand PHILIPS LIGHTOLIEI Calculite IS PB Page 5 of 11 Instruction Sheet for Assembly and Installation of ProSpec Linear Series B ADJUST HOUSING Flanged Aperture Frame Adjust Housing at Mounting Brackets so that bottom edge is flush with finished ceiling as shown Fig 5 Trimless Aperture Frame A Adjust Housing so bottom edge is flush with or above Finished Ceiling Fig 6 B Insert Plaster Frame into Housing Aperture Opening and secure with 6 mounting screws while pushing Plaster Frame against ceiling Fig 7 C Screw Plaster Frame to ceiling and spackle to edge of plaster frame Fig 8 Housing Aperture Opening H Mounting Screw aniy iN ey Do a ee ee Seve hie joes oa es SAS deve Sep ro Dein Pe Bee TE eek s gt oy Se aero i Plaster Frame Figure 5 Figure 6 Figure 7
11. eye inflammation from shortwave ultra violet radiation Do not operate luminaire without protective lens in place Note Install lamps using protective paper and do not remove the protective paper until lamp is installed in socket If lamp is touched with bare hands clean lamp with denatured alcohol and wipe with lint free cloth 631 Airport Road Fall River MA 02720 508 679 8131 e Fax 508 674 4710 We reserve the right to change details of design materials and finish www lightolier com 2008 Philips Group B0908 Lightolier is a Philips group brand PHILIPS LIGHTOLIEI Calculite IS PB Page 3 of 11 Instruction Sheet for Assembly and Installation of ProSpec Linear Series B MARKED SPACING INSTRUCTIONS FOR T4 AND T6 Note For any PB fixtures other than 14 and T6 skip to page 4 Frame In and Wire All T4 and T6 luminaires are limited to their respective placement and location to each other and building members Follow these guidelines in order to determine the placement of luminaires For T4 A Install with minimum spacings between B Center to center of adjacent luminaires 5 152 40cm on center C Top of luminaire to overhead building member 1 2 1 27cm to overhead D Luminaire center to side building member 2 1 2 62 23cm to side of building member For T6 A Install with minimum spacings between B Center to center of adjacent luminaires 6 182 88cm on center C Top of luminaire to overhead building