Home

Lightolier Baselyte-BSL17 User's Manual

image

Contents

1. HOLASI E r Lightolier a Genlyte Company www lightolier com 631 Airport Road Fall River MA 02720 508 679 8131 Fax 508 674 4710 We reserve the right to change details of design materials and finish 2005 Genlyte Group LLC 0205 Rev 1 l Lighting Systems Baselyte BSL17 Page 8 of 8 4 Light T5 HO Semi Indirect Wiring Options 2 Circuit A B Switching alternate 4 sections 2 Circuit A B Switching alternate 4 sections oO Type B 2cct 4 1 z 2 3E Q F oO Type A 2cct w 1cct thru wire 4 1 Ea ae rd k a 4 Q m i ae F 0O Type S 2cct w 2cct thru wire i o a a ae o n Fixture wired for two circuit Lamps wired for A B switching in alternate 4 sections 2 Circuit A B Switching alternate 4 sections with Emergency Circuit Night Light EC NL L Type C 2cct w EC NL 4 Q kja 2 Ba X EC NLNN F 4 Q E O E TCT F 4 Q ae 2 F DS 4 1 4 O F S TTS F One 4 section in a two circuit fixture A B switching to be wired on a separate thru circuit Leads for both normal circuit and EC NL circuit wired to fixture ends All lamps in EC NL section to be wired together 2 Circuit A B Switching alternate 4 sections with Emergency Battery Pack EM L Type D Chloride standard 1 0 rla rla 0 5 CTP700 4 1 a O aii i 1 F C Type O Bodi
2. 5112P23 BSLM5112N BSLM5102N BSLM5104N BSLM5108N 2 Power Mount Non Power Mount P Supension Length 1 Power Mount 2 g 8 12 BSLM3102P13 BSLM3104P13 BSLM3108P13 BSLM3112P13 BSLM3102P14 BSLM3104P14 BSLM3108P14 BSLM3112P14 BSLM3102P17 BSLM3104P17 BSLM3108P17 BSLM3112P17 BSLM3102P23 BSLM3104P23 BSLM3108P23 BSLM3112P23 BSLM3102N BSLM3104N BSLM3108N BSLM3112N Job Information iT is Lightolier a Genlyte Company www lightolier com 631 Airport Road Fall River MA 02720 508 679 8131 Fax 508 674 4710 We reserve the right to change details of design materials and finish 2005 Genlyte Group LLC 0205 Rev 1 WIOLFSOM l Lighting Systems Baselyte BSL17 Page 5 of 8 4 Light T5 HO Semi Indirect O Mount Type Non Accessible Ceilings concrete gypsum etc 1 Power Mount 2 Power Mount Non Power Mount p Supension Length 1 Power Mount 2 g 8 12 3 Conductor BSLM1102P13 BSLM1104P13 BSLM1108P13 BSLM1112P13 ari 4 Conductor BSLM1102P14 BSLM1104P14 BSLM1108P14 BSLM1112P14 e Meets UBC OSHPD and DSA seismic requirements e Canopy Diameter of 5 1 4 x 3 4 power 7 Conductor BSLM1102P17 BSLIM1104P17 BSLM1108P17 BSLM1112P17 e Cable 7x7 stranded aircraft cable 3Power Niou t e Mountable on 0 15 sloped ce
3. BSLM6302P17 BSLM6304P17 BSLM6308P17 BSLM6312P17 Non Power Mount BSLM6302N BSLM6304N BSLIMG308N BSLM6312N Job Information xT Lightolier a Genlyte Company www lightolier com 631 Airport Road Fall River MA 02720 508 679 8131 Fax 508 674 4710 We reserve the right to change details of design materials and finish 2005 Genlyte Group LLC 0205 Rev 1 4 Light T5 HO Semi Indirect WTOLRFSOM l Lighting Systems Baselyte BSL17 Page 4 of 8 Mount Type T Bar Fixed Position 1 4 20 Threaded Rod N Bo 1 Power Mount 3 Conductor 4 Conductor Meets UBC OSHPD and DSA seismic requirements Canopy Diameter of 5 1 4 x 3 4 power Cable 7x7 stranded aircraft cable Tile cut out hole Diameter of 2 1 2 power or 3 4 non power J Box Integral J Box supplied 1 4 20 all thread rod supplied by others Fully vertically adjustable at fixture 2 Power Mount 3 Conductor Non Power Mount Mount Type T Bar Variable Position SOO Lor O E i ED O 5 4 T 1 Power Mount e Meets UBC OSHPD and DSA seismic requirements e Canopy Diameter of 3 x 7 32 e Cable 7x7 stranded aircraft cable e Tile cut out hole Diameter of 2 1 4 e Aligned by T bar
4. Emergency Circuit Night Light EC NL C Type 3 1cct w EC NL 1 Q E Q r TC 1 o 4 1 EANNAN EC NLA F 1 Oo r 4 1 E ISIS EC NL SS F 1 1 aE Q E TCT One 4 section in a one circuit fixture to be wired on a separate thru circuit Leads for both normal circuit and EC NL circuit wired to fixture ends All lamps in EC NL section to be wired together 1 Circuit with Emergency Battery Pack EM pack is wired to one lamp Installer can connect trigger wire to EC hot lead if controlled together or wire separately if controlled independently Leads for normal circuit EC NL circuit and EM wired to fixture ends All lamps in EC NL section to be wired together Note Multi lamp battery packs are also available L Type 5 Chloride standard 4 JE 1 rla rT rE CTP700 4 Q pa Q 4 1 F L Type M Bodine standard 4 Q pja Q E T a ae F LP550 a o o o O Type E Chloride high performance All lamps wired on one circuit plus a battery pack is wired to one lamp A hot lead is connected E CTP1300 o the battery pack and would function as a trigger wire when connected to a constant hot by Type P Bodine high performance installer Leads for both normal circuit and battery pack are wired to fixture ends n Note Multi lamp battery packs are
5. Genlyte Group LLC 0205 Rev 1 l
6. Icct w 1cct Thru wire 9 2cct w 1cct hru wire Note Please consult wiring section of spec sheets for more wiring options Ordering Instructions Individual Fixtures Note Option D is standard Voltage options 1 and 2 are only available with EM Battery and Dimming wiring options 1 Determine the number of individual modules required 2 Order one end set per module 3 Order one non power mount per module 4 Order one power mount per module Continuous Rows 1 Determine run length Order one end set for each run Order one power mount per run oo wh Order the appropriate number and length of modules for complete run Order one non power mount for each module Order one joiner per module minus one e g 3 modules requires 2 joiners Note Some runs may require additional power mounts Please see the Run Configuration table on the next page for more details Job Information Job Name Cat No Lamp s Notes Lightolier a Genlyte Company www lightolier com 631 Airport Road Fall River MA 02720 e 508 679 8131 Fax 508 674 4710 We reserve the right to change details of design materials and finish 2005 Genlyte Group LLC 0205 Rev 1 WIOLFSOM l Lighting Systems Baselyte BSL17 Page 2 of 8 4 Light T5 HO Semi Indirect Per
7. Lighting Systems Baselyte BSL17 Page 1 of 8 4 Light T5 HO Semi Indirect Weight 3 0 Ib ft Ordering Information Family Distribution Lamp Type No of Lamps Housing Module Length Wiring Voltage Ballast Finish BSL 5 H i 04 LN 5 Semi Indirect H T5 HO 04 4 Light LN Perforated 04 4 Tect D Dual120V_ E Standard C Custom Color 08 8 2 2cct amp 277V lt 10 THD W Standard 12 12 3 1cct w EC NL 1 120V F Standard White 4 2cct w EC NL 2 277V lt 10 THD 5 Icct w EM Battery w fusing Specifications Features 1 Housing die formed 20ga cold rolled steel End Set die cast metal with baked powder coat finish Lamping four T5 HO lamps Configuration 4 8 and 12 module lengths or continuous rows Ballasts electronic 120V or 277V om wh Finish High quality white powder coat with textured matte finish Custom colors available Consult factory Mounting Aircraft cable gripper is tamper resistant and provides infinite vertical adjustment capability Aircraft cable crimp and cable gripper independently tested to meet stringent safety requirements Electrical All luminaires are factory pre wired to module ends with quick wire connectors Joints amp Intersections Self aligning joining system with hands free pre joining wire access Labels UL CSA standards 6 2cct w EM Battery 7 1cct w Dimming 8
8. R 65 Ibs maximum load Canopy Diameter of 3 3 4 x 7 32 Cable 7x7 stranded aircraft cable Supported by T bar and secured to structure J Box 4 square supplied by others Fully adjustable vertically at fixture Note Standard T bar mounts are currently not available for tegular tile ceilings however certain tegular tile T bar combinations may be supported by the use of the slot grid mount For more information please consult factory 1 Power Mount Non Power Mount D Supension Length 1 Power Mount 2 g 8 12 3 Conductor BSLM6102P13 BSLM6104P13 BSLM6108P13 BSLM6112P13 4 Conductor BSLM6102P14 BSLM6104P14 BSLM6108P14 BSLM6112P14 7 Conductor BSLM6102P17 BSLM6104P17 BSLM6108P17 BSLM6112P17 Non Power Mount BSLM6102N BSLM6104N BSLM6108N BSLM6112N 1 Power Mount Non Power Mount Supension Length 1 Power Mount 2 g 8 12 3 Conductor BSLM6202P13 BSLM6204P13 BSLM6208P13 BSLM6212P13 4 Conductor BSLM6202P14 BSLM6204P14 BSLM6208P14 BSLM6212P14 7 Conductor BSLM6202P17 BSLM6204P17 BSLM6208P17 BSLM6212P17 Non Power Mount BSLM6202N BSLM6204N BSLM6208N BSLM6212N 1 Power Mount Non Power Mount Supension Length 1 Power Mount 2 g 8 12 3 Conductor BSLM6302P13 BSLM6304P13 BSLM6308P13 BSLM6312P13 4 Conductor BSLM6302P14 BSLM6304P14 BSLM6308P14 BSLM6312P14 7 Conductor
9. also available A 1 Circuit with Emergency Circuit Night Light and Emergency Battery Pack Oo E Type J Chloride standard a CTP700 1 D t Q PE SSS EC NL F 4 1 a 1 F S STITT ANANN a Q t Q F 4 Q yji Q B SS tie F One 4 section in a one circuit fixture to be wired on a separate thru circuit in addition a battery A aa E ail Job Information iT Lightolier a Genlyte Company www lightolier com 631 Airport Road Fall River MA 02720 508 679 8131 Fax 508 674 4710 We reserve the right to change details of design materials and finish 2005 Genlyte Group LLC 0205 Rev 1 l Lighting Systems Baselyte BSL17 Page 7 of 8 4 Light T5 HO Semi Indirect Wiring Options 2 Circuit Center Outer Switching 2 Circuit Center Outer Switching oO Type 2 2cct oO Type 9 2cct w 1cct thru wire oO Type I 2cct w 2cct thru wire hh Seae oy oh i i Sead oo maram N I IN oy nA Fixture wired for two circuit Lamps wired for center outer switching 2 Circuit Center Outer Switching with Emergency Circuit Night Light EC NL L Type 4 2cct w EC NL 4 O pla 2 EN V EC NLN SE 4 Q t Q BEN X EC NL AN F 4 Q 4 1 E Ae TTS F 4 2 z 2 EE ANNANN JS F One 4 section in two circuit fixture center outer switching to be wired on a separate thru circuit Leads for both normal circuit and EC NL circuit wired to f
10. and secured to structure e J Box 4 square supplied by others e Fully vertically adjustable at fixture e Adjusts to both 1 and 1 1 2 high T bar systems 3 Conductor 4 Conductor 7 Conductor 2 Power Mount 3 Conductor Note Supports 15 16 9 16 and slot grid ceiling types Non Power Mount Mount Type Support or Open Joist Ceiling 1 Power Mount 3 Conductor 4 Conductor Meets UBC OSHPD and DSA seismic requirements Canopy Diameter of 5 1 4 x 3 4 power Cable 7x7 stranded aircraft cable Versatile mount fully adjustable to accomodate open sloped ceilings J Box 4 octogonal box supplied by others Fully vertically adjustable at fixture 7 Conductor 2 Power Mount 3 Conductor Non Power Mount 4 Light T5 HO Semi Indirect 2 Power Mount Non Power Mount p Supension Length z g 8 12 BSLM2108P13 BSLM2112P13 1 Power Mount BSLM2102P13 BSLM2104P13 BSLM2102P14 BSLM2104P14 BSLM2108P14 BSLM2112P14 BSLM2102P23 BSLM2104P23 BSLM2108P23 BSLM2112P23 BSLM2102N BSLM2104N BSLM2108N BSLM2112N 2 Power Mount Non Power Mount P Supension Length 1 Power Mount z g 8 12 BSLM5102P13 BSLM5104P13 BSLM5108P13 BSLM5112P13 BSLM5102P14 BSLM5104P14 BSLM5108P14 BSLM5112P14 BSLM5102P17 BSLM5104P17 BSLM5108P17 BSLM5112P17 BSLM5102P23 BSLM5104P23 BSLM5108P23 BSLM
11. er mounts may be required for some runs with T5 HO controls all lamps or optional battery pack controls one or two lamps lamping options longer runs and runs with wiring options that are more complex Please consult factory for assistance System Components amp Accessories End Set Joiner e a SS o BSLESW suspended standard white BSLJS suspended joiner HIQOLAHSE II E r Lightolier a Genlyte Company www lightolier com 631 Airport Road Fall River MA 02720 508 679 8131 Fax 508 674 4710 We reserve the right to change details of design materials and finish 2005 Genlyte Group LLC 0205 Rev 1 l Lighting Systems Baselyte BSL17 Page 3 of 8 Mounting Options Mount Type T Bar 15 16 On Grid 65 Ibs maximum load Canopy Diameter of 3 3 4 x 7 32 Cable 7x7 stranded aircraft cable Supported by T bar and secured to structure J Box 4 square supplied by others Fully adjustable vertically at fixture Mount Type T Bar 9 16 On Grid o0 65 Ibs maximum load Canopy Diameter of 3 3 4 x 7 32 Cable 7x7 stranded aircraft cable Supported by T bar and secured to structure J Box 4 square supplied by others Fully adjustable vertically at fixture Mount Type T Bar 9 16 by 5 16 Slot Grid On Grid lal O D 5 f
12. formance Candlepower Curve Candlepower Summary Coefficients of Utilization My ZONE CANDLEPOWER EFFECTIVE CEILING CAVITY REFLECTANCE C A DEG 0 22 5 45 67 5 90 m 180 4535 4535 4535 4535 4535 amp 175 4511 4513 4528 4538 4542 165 4347 4377 4448 4493 4508 0 2 55 4041 4109 4228 4313 4351 l 8 45 3601 3708 3907 4090 4165 3 135 3046 3188 3531 3842 3957 4 125 2389 2602 3123 3461 3575 5 m a 115 1672 2004 2541 2699 2756 6 on 8 05 906 1310 1574 1575 1608 7 s 95 171 325 395 318 334 8 w s 90 6 1 37 55 64 9 a a 85 16 2 4 62 70 10 8 2 75 25 3 amp l 85 M4 65 33 53 84 107 116 55 50 75 102 127 136 45 76 94 118 137 145 Report No 9900158 35 105 114 134 148 155 Zonal Lumen Summary Lamps F54T5 5 129 134 148 156 160 ZONE LUMENS BARELAMP LUMINAIRE Lumens per Lamp 4650 15 145 147 153 161 163 0 90 576 3 1 35 Efficiency 87 6 5 155 154 155 156 155 90 180 15725 84 5 96 5 Up 96 5 Down 3 5 0 156 156 156 156 156 0 180 16301 87 6 100 0 Module Lengths amp Mounting Distances Run Configuration 4 7 P E Run 4 8 12 x Power Module Length Length Module Module Module omer EndSet Mount Moun Mounting Distance 4 run 1 1 1 p 8 run 1 1 1 lt 8 gt 12 run 1 1 1 Module Length Mounting Distance 16 nun A 1 1 2 20 run 1 1 1 1 2 12 24 run 2 1 1 2 lt gt Module Length Mounting Distance 28 run 2 1 2 1 3 32 run 1 2 2 1 3 Note Shaded area indicates locations of emergency sections emergency wiring Note Additional pow
13. iling e Optional Chicago Plenum approved version available A4 3 Conductor BSLM1102P23 BSLM1104P23 BSLM1108P23 BSLM1112P23 e J Box 4 octogonal box supplied by others e Fully vertically adjustable at fixture Non Power Mount BSLM1102N BSLM1104N BSLM1108N BSLM1112N Cord Types 3 Conductor 4 Conductor LI 7 Conductor C U e Max 10 amps e Max 10 amps in a 1 circuit application e Max 10 amps in a 1 circuit application e Max 300V e Max 5 amps per circuit in a 2 circuit application Max 5 amps per circuit in a multi circuit e Max 300V application e Good for 2 circuit feeds or a 1 circuit feed with e Good for 3 circuit feeds or 2 circuit feeds with a a battery pack hot lead battery pack hot lead e 120V or 277V applications e 120V or 277V applications HIQOLAHSE II Job Information i s Lightolier a Genlyte Company www lightolier com 631 Airport Road Fall River MA 02720 508 679 8131 Fax 508 674 4710 We reserve the right to change details of design materials and finish 2005 Genlyte Group LLC 0205 Rev 1 l Lighting Systems Baselyte BSL17 Page 6 of 8 4 Light T5 HO Semi Indirect Wiring Options 1 Circuit 1 Circuit C type 1 tcct 1 F 4 m4 JE T F 4 ae Esa F oO Type 8 1cct w 1cct thru wire 1 o pla o rla o n O Type H 1cct w 2cct thru wire 4 1 1 E Oo i O Type 7 1cct w dimming All lamps wired on one circuit 1 Circuit with
14. ixture ends All lamps in EC NL section to be wired together 2 Circuit Center Outer Switching with Emergency Battery Pack EM L Type 6 Chloride standard 4 rla rla CTP700 4 Q pja Q rja 1 F C Type N Bodine standard 4 Q F Q BASS LP550 41 O a 2 E 2 F O Type F Chloride high performance Fixture wired for two circuits center outer switching plus a battery pack is wired to one lamp A CTP1300 hot lead is connected to the battery pack and would act as a trigger wire when connected to a E Type Q Bodine high performance constant hot by installer Leads for both normal circuit and battery pack are wired to fixture ends LP600 Note Multi lamp battery packs are also available 2 Circuit Center Outer with Emergency Circuit Night Light and Emergency Battery Pack L Type K Chloride standard 4 rla r2 m CTP700 4 Q 4 Q E TCT 4 Q pjd Q 4 2 E 2 r S SI One 4 section in a two circuit fixture center outer switching to be wired on a separate thru circuit in addition a battery pack is wired to one lamp Installer can connect trigger wire to EC hot lead if controlled together or wired separately if controlled independently Leads for normal circuit EC NL circuit and battery pack are wired to fixture ends All lamps in EC NL section to be wired together Note Multi lamp battery packs are also available
15. ne standard a Q ria 12 F aS S1 EM SG 4 Q ja 2 j4 Q F LP550 L Type G Chloride high performance Fixture wired for two circuits A B switching plus a battery pack is wired to one lamp A hot lead CTP1300 is connected to the battery pack and would act as a trigger wire when connected to a constant hot C Type R Bodine high performance by installer Leads for both normal circuit and battery pack are wired to fixture ends LP600 Note Multi lamp battery packs are also available 2 Circuit A B Switching alternate 4 sections with Emergency Circuit Night Light and Emergency Battery Pack L Type L Chloride standard 1 D pja 21 E Se RP CTP700 4 Q E 2 E SST SSS 4 Q E 2 F S a N 4 Q IE 2 IEN One 4 section in a two circuit fixture A B switching to be wired on a separate thru circuit in addition a battery pack is wired to one lamp Installer can connect trigger wire to EC hot lead if controlled together or wired separately if controlled independently Leads for normal circuit EC NL circuit and battery pack are wired to fixture ends All lamps in EC NL section to be wired together Note Multi lamp battery packs are also available WIOLRFSOM Job Information iT Lightolier a Genlyte Company www lightolier com 631 Airport Road Fall River MA 02720 508 679 8131 Fax 508 674 4710 We reserve the right to change details of design materials and finish 2005