Home

LG PCS150R User's Manual

image

Contents

1. 19 20 Power Sources This product should be operated only from the type of power source indicated on the marking label If you are not sure of the type of power supply to your INSTALLATION consult your product dealer or local power company Overloading Do not overload wall power outlets and extension cords as this can result in a risk of fire or electric shock Disconnect Device The AC mains plug is used as the discon nect device The disconnect device must remain readily operable Object and Liquid Entry Never push objects of any kind into this prod uct through openings as they may touch dan gerous voltage points or short out parts that could result in a fire or electric shock Never spill liquid of any kind on the product Do not use liquid cleaners or aerosol cleaners Outdoor Use Warning To prevent fire or shock hazards do not expose this product to rain or moisture Wet Location Do not use this product near water or mois ture or in an area such as a basement that might become flooded The apparatus shall not be exposed to dripping or splashing and no objects filled with liquids such as vases shall be placed on the apparatus Test Equipment In some cases LG has supplied or recom mended the use of test equipment and devic es for the setup and testing of the equipment The operation and maintenance of test equip ment is described in their associated instruc tion manuals Please refer to these
2. LG PCS150R Pro Centric Server Installation amp Setup Guide Warranty Copyright 2011 LG Electronics U S A Inc P N 206 4157 Rev A For Customer Support Service please call 1 888 865 3026 The latest product information and documentation is available online at www LGsolutions com products 5 WARNING RISK OF ELECTRIC SHOCK DO NOT OPEN WARNING TO REDUCE THE RISK OF ELECTRIC SHOCK DO NOT REMOVE COVER OR BACK NO USER SERVICEABLE PARTS INSIDE REFER TO QUALIFIED SERVICE PERSONNEL the user to the presence of uninsulated dangerous voltage within the produc s enclosure The lightning flash with arrowhead symbol within an equilateral triangle is intended to alert that may be of sufficient magnitude to constitute a risk of electric shock to persons of important operating and maintenance servicing instructions in the literature accompanying The exclamation point within an equilateral triangle is intended to alert the user to the presence the appliance WARNING TO PREVENT FIRE OR SHOCK HAZARDS DO NOT EXPOSE THIS PRODUCT TO RAIN OR MOISTURE Apparatus shall not be exposed to dripping or splashing and no objects filled with liquids such as vases shall be placed on the apparatus L appareil ne doit pas tre expos des gouttements d eau ou des claboussures et de plus qu aucun objet rempli de liquide tel que des vases ne doit tre plac sur l appareil REGULATORY INFORMATION This equip
3. Otherwise the system will confirm the configuration updates and prompt you to reset the PCS150R New configuration has been saved Please restart the system 12 Reset the PCS150R see Reset the PCS150R on page 22 Set the Time Zone 1 2 18 Log in to the PCS150R as described on page 13 Atthe Command gt prompt type tz and press Enter The system displays the current time zone information for the PCS150R and prompts you to specify whether or not you wish to change the time zone Current time zone is America New York Change the time zone y n Either Type n and press Enter to return to the Main Menu Command gt prompt without changing the current time zone e Type y and press Enter to change the time zone Then continue with step 4 Continued on next page 206 4157 PCS150R Configuration Options Cont Continued from previous page 4 The system displays the following prompt for a location followed by a list of options Please identify a location so that time zone rules can be set correctly Please select a continent or ocean Atthe prompt type the number that corresponds to the appropriate option for your location and then press Enter 5 The system displays the following prompt for a country followed by a list of options Please select a country At the prompt type the number that corresponds to the appropriate option for your country and then press Enter
4. showing your update Note Assign video and elementary PIDS as necessary according to the system s network distribution requirements Continued on next page 206 4157 15 PCS150R Configuration Options Cont Continued from previous page e Elementary PID There are four Elementary PIDs Type 4 5 6 or 7 depending on which Elementary PID you wish to change and press Enter Atthe Enter new value for Elementary PID prompt type the new Elementary PID and press Enter The system will redisplay the video configuration showing your update Note Assign video and elementary PIDS as necessary according to the system s network distribution requirements 4 Atthe Select parameter to change or press Enter to accept prompt select another parameter to change if desired and follow the prompts or press Enter to accept the displayed configuration parameters and return to the Command gt prompt Configure the TCP IP Settings 1 Log in to the PCS150R as described on page 13 2 Atthe Command gt prompt type setip and press Enter 16 The system displays an overview of the current TCP IP network configuration followed by a Network Configuration Menu for example Current Network Configuration Interface eth0 Host name pcs150r Using DHCP YES Interface ethl Host name pcs150r Using DHCP YES DNS servers Primary DNS 68 94 156 1 Secondary DNS 68 94 157 1 eth0 Configure eth0 eth1 C
5. 1994 1995 Tatu Ylonen Espoo Finland Copyright 1998 CORE SDI S A Buenos Aires Argentina Copyright 1995 1996 by David Mazieres Copyright 1980 1983 1987 1988 1990 1992 1993 1995 The Regents of the University of California Copyright 1999 2000 2001 2002 2003 2004 Markus Friedl Copyright 1995 1996 1998 1999 Theo de Raadt Copyright 1999 2000 2001 2002 Niels Provos Copyright 1999 Dug Song Copyright 1999 Aaron Campbell Copyright 1999 2000 2001 2002 2003 2004 2005 Damien Miller Copyright 2001 Kevin Steves Copyright 2002 Daniel Kouril Copyright 2003 Wesley Griffin Copyright 2001 Per Allansson Copyright 2002 2003 Nils Nordman Copyright 2001 2003 Simon Wilkinson Copyright 2000 2001 2003 Ben Lindstrom Copyright 2002 2005 Tim Rice Copyright 2000 Andre Lucas Copyright 2002 Chris Adams Copyright 2000 2001 Corinna Vinschen Copyright 2002 Cray Inc Wendy Palm Copyright 2000 Denis Parker Copyright 2001 Gert Doering Copyright 2001 2003 Jakob Schlyter Copyright 1996 Jason Downs 206 4157 Copyright 2002 Juha Yrj l Copyright 2000 Michael Stone Copyright 2002 Networks Associates Technology Inc Copyright 1997 1998 2000 2002 2004 Todd C Miller Copyright 2003 2004 2005 Darren Tucker Copyright 1988 2002 Sun Microsystems Inc Copyright 2005 The SCO Group Copyright 2004 The OpenBSD Project Copyright 2005 Anil Madha
6. manuals for explicit instructions regarding the safe use and handling of the equipment Continued on next page IMPORTANT SAFETY INSTRUCTIONS Continued from previous page 21 22 23 Damage Requiring Service Unplug this product from the wall power out let and refer servicing to qualified service personnel under the following conditions a If the power supply cord or plug is damaged b If liquid has been spilled or objects have fallen into the product c If the product has been exposed to rain or water d If the product does not operate normally by following the operating instructions Adjust only those controls that are covered by the operating instructions as an improper adjustment of other controls may result in damage and will often require extensive work by a qualified technician to restore the product to its normal operation e If the product has been dropped or the cabinet has been damaged f If the product exhibits a distinct change in performance Caution Refer all servicing to qualified service personnel Servicing Caution These servicing instruc tions are for use by qualified ser vice personnel only To reduce the risk of electrical shock do not perform any servicing other than that described in the operating instructions unless you are qualified to do so Replacement Parts When replacement parts are required be sure the service technician uses replacement parts specifi
7. provide the model number serial number and date of purchase or date of original installation For Customer Support Service please call 1 888 865 3026 www LGsolutions com Pro Centric is a trademark of LG Electronics U S A Inc All other trademarks or registered trademarks are the property of their respective owners 206 4157 Copyright 2011 LG Electronics U S A Inc Revision A
8. 6 The system displays the following prompt for a region followed by a list of options Please select one of the following time zone regions At the prompt type the number that corresponds to the appropriate option for your region and then press Enter After you specify the time zone region the system displays an overview of your location selections and prompts for confirmation for example The following information has been given United States Central Time Therefore TZ America Chicago will be used Local time is now Tue May 24 16 23 10 CST 2011 Universal Time is now Tue May 24 22 23 10 UTC 2011 Is the above information OK 1 Yes 2 No 7 Either Type 1 and press Enter if the information in the display is correct The system will confirm the setting and then prompt you to reset the PCS150R Time zone has been set Please reset the board Continue with step 8 Type 2 and press Enter to return to the initial location prompt and reset the time zone repeat this procedure from step 4 8 Reset the PCS150R see Reset the PCS150R on page 22 206 4157 19 PCS150R Configuration Options Cont Change the Login Password 1 Log in to the PCS150R as described on page 13 2 Atthe Command gt prompt type pwd and press Enter The system prompts for the current password Changing password for admin Old password 3 Type the current password and press Enter The system will t
9. 7 IMPORTANT SAFETY INSTRUCTIONS Continued from previous page B Reduced Air Flow Installation of the equipment in a rack should be such that the amount of air flow required for safe operation of the equipment is not compromised To ventilate the system nor mally and avoid overheating leave at least 1 inch 2 5 cm on each side including top and bottom of the PCS150R Do NOT stack other equipment on the top of the PCS150R Circuit Overloading Consideration should be given to the con nection of the equipment to the supply circuit and the effect that overloading of the circuits might have on overcurrent protection and supply wiring Reliable Earthing Maintain reliable earthing of rack mounted equipment Particular attention should be given to supply connections other than direct connections to the branch circuit e g use of power strips 206 4157 E Mains Outlet Earthing The apparatus with Class construction must be connected to a mains socket outlet with a protective earthing connection PCS150R Installation on a Flat Surface To install the PCS150R on a level surface table top shelf etc Install the equipment in an environment com patible with the maximum operating ambient temperature Tma specified by the manufac turer see Specifications information in this document Place spacers or rubber feet not provided on the bottom of the PCS150R Carefully place the PCS150R on the level surf
10. D 4096 default 3 Video PID 4097 default 4 Elementary PIDI 4098 default 5 Elementary PID2 4099 default 6 Elementary PID3 4100 default 7 Elementary PID4 4101 default Select parameter to change or press Enter to accept 3 To return to the Command gt prompt without making any changes you can simply press Enter Otherwise select the appropriate option depending on the parameter you wish to change e Program Number Type 1 and press Enter to change the video program number Atthe Enter new value for Program number 47 prompt type a new program number and press Enter The system will redisplay the video configuration showing your update Note The video channel major number is the RF data channel assigned for Pro Centric operation Installer Menu item 119 DATA CHANNEL and the video channel minor program number is as configured in this step default program number 47 Refer to Commercial Mode Setup documentation for the TV in question for further information PMT ID Type 2 and press Enter to change the PMT Program Map Table PID packet ID Atthe Enter new value for PMT PID 4096 prompt type the new PMT ID and press Enter The system will redisplay the video configuration showing your update Video PID Type 3 and press Enter to change the video PID Atthe Enter new value for Video PID 4097 prompt type the new video PID and press Enter The system will redisplay the video configuration
11. Enter The System Information display identifies important information about the PCS150R including the unit serial number hardware ID firmware version software versions MAC addresses and IP addresses for example SN Hardware ID OS version OS release Eth0 MAC EthO IP Eth1 MAC Ethl IP VPN IP RF config RF channel Local time PCS150R Pro Centric Server v4 5 001 12410005 L 1 0 1 Linux 2 6 38 zenith 204 Mon May 2 17 21 54 CDT 2011 00 0C 63 3B 00 55 192 168 10 77 00 0C 63 3B 00 65 n a 10 7021 Mode 3 QAM B RF 6 MHz 5 36 MSps ASI 38 81 Mbps 69 Wed May 18 16 08 12 CDT 2011 It is recommended that you record this information for future reference If you find it necessary to call customer service or engineering support please have this information available This field only appears if RF output is configured for QAM B modulation If RF output is configured for DVB C modulation the display will identify the RF frequency in KHz 14 206 4157 PCS150R Configuration Options Cont Configure Video Parameters This option enables you to view current settings and or configure new settings as required 1 Log in to the PCS150R as described on page 13 2 Atthe Command gt prompt type video and press Enter The system displays the current video parameters and prompts for a selection for example Current video configuration 1 Program number 47 default 2 PMT PI
12. FOR ANY CLAIM DAMAGES OR OTHER LIABILITY WHETH ER IN AN ACTION OF CONTRACT TORT OR OTHER WISE ARISING FROM OUT OF OR IN CONNECTION WITH THE SOFTWARE OR THE USE OR OTHER DEALINGS IN THE SOFTWARE EVEN IF LICENSOR HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES LICENSEE ASSUMES THE COST OF ALL NECESSARY SERVICING REPAIR OR CORRECTION 25 LG PCS150R Pro Centric Server Warranty Broadcast Products Welcome to the LG family We believe that you will be pleased with your new PCS150R Pro Centric Server Please read this warranty carefully it is a LIMITED WARRANTY as defined under Federal Law This warranty gives you specific legal rights and you may also have other rights that vary from state to state within the U S A LG s RESPONSIBILITY Warranty Term One year parts and labor from date of purchase or delivery date Parts New or remanufactured replacements for factory defective parts may be used Such replacement parts are warranted for the remaining portion of the original warranty period Warranty Service Warranty service is provided at LG Customer pays for shipping charges to LG LG pays for return shipping charges to return PCS150R Pro Centric Server to customer Call 1 888 865 3026 for further information Not Covered This warranty covers manufacturing defects and does not cover installation adjustment of customer controls installation or repair of antenna systems cable converters or cable company supplied equipmen
13. Front Panel Overviews PCS150R Rear View Fou X d B gt Disconnect Device penn A The AC mains plug is used ASI Out as the disconnect device The disconnect device must NETWORK remain readily operable Ethernet Ports USB Ports Power Supply Cord PCS150R Front View Ventilation Holes Air flow must not be obstructed STATUS LED To ventilate the system normally and avoid overheating leave at least 1 inch 2 5 cm on each side including top and bottom of the PCS150R Do NOT stack other equipment on the top of the PCS150R 8 206 4157 Rack Installation Typical PCS150R Rack Installation 1 Carefully slide the chassis into a standard 19 inch equipment rack 2 Use all four mounting screws to secure the chassis to the rack Rack mount Considerations A Elevated Operating Ambient If installed in a closed or multi unit rack assembly the operating ambient temperature of the rack environment may be greater than room ambient Therefore consideration should be given to installing the equipment in an environment compatible with the maximum ambient temperature Tma specified by the manufacturer see Specifications information in this document Reduced Air Flow Installation of the equipment in a rack should be such that the amount of air flow required for safe operation of the equipment is not compromised To ventilate the system nor mally and avoid overheating leave at least 1 inc
14. ace To ventilate the system normally and avoid overheating leave at least 1 inch 2 5 cm on each side including top and bottom of the PCS150R Do NOT stack other equipment on the top of the PCS150R Table of Contents Setup Checklist Table of Contents Safety Warnings 2 System Setup 10 12 Important Safety Instructions 3 5 PCS150R Configuration Options 13 22 Table of Contents Setup Checklist 6 Troubleshooting Specifications 23 PCS150R Product Description 7 Document Revision History Notes 24 Rear and Front Panel Overviews 8 Open Source Software Notice 25 Rack Installation 9 Warranty Back Cover Setup Checklist Check the items listed below before you begin the PCS150R installation and setup procedures ASI Output Optional __ If the system is using ASI ouput install the modulator and upconverter that will receive the ASI output signal from the PCS150R Refer to the manufacturer s documentation PCS150R Unpack the PCS150R Pro Centric server unit and all accessories Accessories provided Power Cord and Adapter Select the location for mounting the PCS150R Ensure that adequate ventilation is available Obtain the necessary attachment hardware to mount the PCS150R chassis in its targeted location Plan and install the necessary cabling and netw
15. e Reset the PCS150R on page 22 20 206 4157 PCS150R Configuration Options Cont Update PCS150R Application or OS Software via Serial Link Caution Do NOT initiate simultaneous menu sessions while a software update is in progress Doing so may interfere with the active process and may corrupt the system configuration and or cause the PCS150R to cease normal operation This option enables you to update the PCS150R application or OS software via a serial link to the PCS150R Refer to Update PCS150R Application or OS Software via Ethernet on the previous page for information on updating software via the Ethernet The appropriate update file must be provided by LG The system will not transfer an improper file 1 Log in to the PCS150R as described on page 13 2 Atthe Command gt prompt type updser and press Enter The system prompts for the file PCS150R Serial Update Tool v1 1 Copyright C 2010 Zenith Electronics LLC Send file using XMODEM 3 At the system prompt transfer the new application OS file using Xmodem protocol For example in HyperTerminal select Transfer and then Send File In the Send File window enter or select the appropriate filename in the Filename field and select Xmodem in the Protocol field The system will display progress messages as well as the result of the update process which may take several minutes 4 When the update is successfully completed the system may prompt
16. ed by the manufacturer or that have the same characteristics as the original parts Unauthorized substitutions may result in fire electric shock or other hazards 24 Safety Check Upon completion of any service or repairs to this product ask the service technician to perform safety checks to determine that the product is in proper operating condition PCS150R Rack Installation also see page 9 To install the PCS150R in a rack e Carefully slide the PCS150R into a standard 19 inch equipment rack When mounted in the rack make sure appro priate hardware is used ALL FOUR MOUNT ING SCREWS MUST BE USED This equipment is not designed to support other devices Do NOT stack other equipment on the top of the PCS150R Rear cabling must be dressed and supported so that the weight of the cabling is not a strain on the PCS150R connectors MOUNTING OF THE EQUIPMENT IN THE RACK SHOULD BE SUCH THAT A HAZARD OUS CONDITION IS NOT ACHIEVED DUE TO UNEVEN MECHANICAL LOADING Rack mount Considerations A Elevated Operating Ambient If installed in a closed or multi unit rack assembly the operating ambient tempera ture of the rack environment may be greater than room ambient Therefore consideration should be given to installing the equipment in an environment compatible with the maximum ambient temperature Tma specified by the manufacturer see Specifications information in this document Continued on next page 206 415
17. h 2 5 cm on each side including top and bottom of the PCS150R Do NOT stack other equipment on the top of the PCS150R unit 206 4157 Circuit Overloading Consideration should be given to the con nection of the equipment to the supply circuit and the effect that overloading of the circuits might have on overcurrent protection and supply wiring Reliable Earthing Maintain reliable earthing of rack mounted equipment Particular attention should be given to supply connections other than direct connections to the branch circuit e g use of power strips Mains Outlet Earthing The apparatus with Class construction must be connected to a mains socket outlet with a protective earthing connection System Setup Refer to the following diagrams and complete the system installation as described on pages 11 and 12 Typical Setup Flow Charts for the PCS150R ASI Output RF RS 232 Port Distribution Connection System QAM Modulator RF Output PCS150R _ RF Out RS 232 Port Connection L____ Combiner Distribution RF System Cable 10 l 206 4157 System Setup Cont VPN Network Connections Overview Pro Centric VPN Server VPN Client PCS150R Internet VPN VPN Client Typical System Installation see also Typical Setup Flow Charts and VPN Network Connections Overview diagrams 1 If your syste
18. hen prompt you to type and retype the new password New password Retype password 4 Type and then retype the new password at the prompts Press Enter after each entry Once you complete the Password fields successfully the system displays confirmation Password for admin changed by admin Update PCS150R Application or OS Software via Ethernet Caution Do NOT initiate simultaneous menu sessions while a software update A is in progress Doing so may interfere with the active process and may corrupt the system configuration and or cause the PCS150R to cease normal operation This option enables you to update the PCS150R application or OS software via the Ethernet Refer to Update PCS150R Application or OS Software via Serial Link on the next page for information on updating software via a serial link The appropriate update file must be provided by LG The system will not download an improper file 1 Log in to the PCS150R as described on page 13 2 Atthe Command gt prompt type update and press Enter The system prompts for the update filename PCS150R Update Tool v1 2 Copyright C 2010 Zenith Electronics LLC Enter update filename 3 Type in the filename and press Enter The system will initiate the download and confirm progress for example Downloading file pcs150r app xxxx upd 4 When the update is successfully completed the system may prompt you to reset the PCS150R If necessary reset the server se
19. k any ventilation openings Install in accordance with the manufac turer s instructions Do not install near any heat sources such as radiators heat registers stoves or other apparatus including amplifiers that produce heat Do not defeat the safety purpose of the polarized or grounding type plug A polar ized plug has two blades with one wider than the other A grounding type plug has two blades and a third grounding prong The wide blade or the third prong are pro vided for your safety If the provided plug does not fit into your outlet consult an electrician for replacement of the obsolete outlet Protect the power cord from being walked on or pinched particularly at plugs convenience receptacles and the point where it exits from the apparatus Only use attachments accessories speci fied by the manufacturer Use only with the cart stand tripod bracket or table specified by the manu facturer or sold with the apparatus When a cart is used use caution when moving the cart apparatus combination in order to avoid injury from tip over Refer all servicing to qualified service personnel Servicing is required when the apparatus has been damaged in any way such as power supply cord or plug is damaged liquid has been spilled or objects have fallen into the apparatus the apparatus has been exposed to rain or moisture does not operate normally or has been dropped 206 4157 14 15 16 17 18
20. m is using ASI output make the following two connections otherwise go to step 2 e Connect a 75 ohm BNC to BNC coaxial cable between ASI OUT on the PCS150R and ASI IN on the modulator A Note The BNC cable must be less than 30 feet 9 2 meters in length e Connect an RF coaxial cable between IF OUT on the modulator and IF IN on the upcon verter Connect one end of a CAT5 RJ 45 Ethernet cable to the ETHERNET O port on the PCS150R rear panel and connect the other end of the cable to the institution s network 3 Connect the PCS150R power supply to the POWER connector on the PCS150R rear panel 4 Use the straight through serial cable and if necessary the USB adapter to connect a PC to the RS 232 port on the PCS150R rear panel This step will enable you to verify the network connection once power is applied in step 6 Using HyperTerminal or an equivalent terminal emulation program on the PC configure the serial port as follows Bits per second 115200 Data bits 8 Parity None Stop bits 1 Flow Control None Continued on next page 206 4157 11 System Setup Cont Continued from previous page 6 Plug the AC power cord into a powered AC line receptacle When power is applied the STATUS LED on the PCS150R front panel will light and you will see boot up messages on the PC When the boot up is complete a System Information display identifies important information about the PCS150R including the u
21. ment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial envi ronment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user should be required to correct the interference at his own expense CAUTION Do not attempt to modify this product in any way without written authorization from LG Electronics U S A Inc Unauthorized modification could void the user s authority to operate this product COMPLIANCE The responsible party for this product s compliance is LG Electronics U S A Inc 2000 Millbrook Drive Lincolnshire IL 60069 USA Phone 1 847 941 8000 Marketed and Distributed in the United States by LG Electronics U S A Inc 2000 Millbrook Drive Lincolnshire IL 60069 2 Copyright 2011 LG Electronics U S A Inc 206 4157 EO ON Br TNT 10 11 12 13 IMPORTANT SAFETY INSTRUCTIONS Read these instructions Keep these instructions Heed all warnings Follow all instructions Do not use this apparatus near water Clean only with dry cloth Do not bloc
22. nd press Enter to end the current session 22 206 4157 Troubleshooting Specifications Troubleshooting If the PCS150R is not connecting to the network during system setup i e the EthO IP field in the System Information display see setup procedure on page 12 is blank 1 Check the ETHERNET O connector on the rear panel of the PCS150R Make sure the cable connection is tight and secure 2 Observe the green LED on the ETHERNET O port Once the PCS150R is connected to the network the LED will be lit continuously 3 Contact the network administrator to verify the network status Specifications Dimensions Height 1 692 inches 42 977 mm Width 19 0 inches 482 6 mm for EIA standard 19 inch rack mount Depth 8 5 inches 215 9 mm Weight 3 45 pounds 1 56 kgrms rack only weight Environmental Storage Conditions Temperature 20 to 70 Celsius 4 to 158 Fahrenheit Humidity 95 non condensing Environmental Operating Conditions Temperature Tma 0 to 40 Celsius 32 to 104 Fahrenheit Humidity 95 non condensing Electrical DC Input 12V DC 4 0 Amps Impedance at ASI Out jack 75 ohms Level at ASI Out jack 800 mv Ethernet 10 100 1000BaseT Note Design and specifications subject to change without prior notice 206 4157 23 Document Revision History Notes Document Revision History Date Description May 2011 Revision A New document Product documentation is available online at w
23. nit serial number hardware ID firmware version soft ware versions MAC addresses and IP addresses for example PCS150R Pro Centric Server v4 5 SN 001 12410005 Hardware ID 1 1 0 1 OS version Linux 2 6 38 zenitht OS release 204 Mon May 2 17 21 54 CDT 2011 EthO MAC 00 0C 63 3B 00 55 EthO IP 192 168 10 77 Eth1 MAC 00 0C 63 3B 00 65 Ethl IP n a VPN IP n a RF config Mode 3 QAM B RF 6 MHz 5 36 MSps ASI 38 81 Mbps RF channel 69 Local time Wed May 18 16 08 12 CDT 2011 7 Check the EthO IP field in the display By default the PCS150R uses DHCP thus the DHCP server assigns an IP address to the PCS150R once the PCS150R successfully connects to the network If the EthO IP field shows an IP address the PCS150R is up and running on the network If the EthO IP field is blank refer to Troubleshooting information on page 23 8 Make the appropriate connection to the RF distribution system ASI output Connect the RF output on the upconverter to the RF distribution center combiner and balance the RF signal so that the Pro Centric signal level at the TV s is between 0 to 7 dBmvV RF output Connect RF OUT on the PCS150R to the RF distribution center combiner and balance the RF signal so that the Pro Centric signal level at the TV s is between 0 to 7 dBmvV Caution For proper system performance the Pro Centric signal level at the TV input ANTENNA IN must be between 0 to 7 dBmV Note tha
24. onfigure ethl dns Configure dns exit Exit network configuration Choose item to modify gt Continued on next page 206 4157 PCS150R Configuration Options Cont Continued from previous page 3 Either e Continue with step 4 for information on modifying the configuration a PCS150R Ethernet port Go to step 9 for information on modifying the DNS configuration e To exit the Network Configuration Menu without modifying any settings type exit at the Network Configuration Menu gt prompt 4 Type eth0 or eth1 as applicable to modify the configuration of the desired Ethernet port Then press Enter 5 Atthe Host name pcs150r prompt either press Enter to accept the default value in square brackets or type a new host name and then press Enter 6 Atthe Using DHCP Y N Y prompt type y if the PCS150R uses DHCP or type n to specify the network IP addresses Then press Enter 7 Ifthe PCS150R is NOT using DHCP type the information requested at each of the following prompts Press Enter after each entry This host IP address Type the host IP address in the format xxx xxx xxx xxx Network mask Type the netmask in the format xxx xxx xxx xxx Gateway IP address Type the IP address of the default gateway in the format xxx xxx xxx xxX 8 Once you enter the gateway address the system will redisplay the Network Configuration Menu e To modify the configuration of the second Ethernet port re
25. ork Ethernet and AC power access for the PCS150R You will also need the following to connect a PC directly to the PCS150R for system setup verification purposes DB9 Male to DB9 Female RS 232 straight through serial cable Example Cables Unlimited PCM 2100 06 serial cable e Optional USB 2 0 to serial DB9 adapter Example Cables Unlimited USB 2920 adapter If there is no serial port on the PC use the adapter to connect the serial cable to the PC Carefully follow the installation procedure for the PCS150R see page 9 Complete the system setup for the PCS150R see pages 10 to 12 6 206 4157 PCS150R Product Description The PCS150R Pro Centric server is a stand alone remotely controlled processor and controller for the Pro Centric system This device can be used to capture data from an Internet source assemble the data as display pages and output the pages in DTV format over an ASI or RF interface With appropriate post processing the ASI or RF signal can then be used for either IP or RF distribution in a lodging site application Features Two output options ASI or RF RF output channel programmable Remote programming capability via Ethernet Unit does not require local monitor keyboard or mouse connection Small lightweight chassis 19 inch rack mountable 1U height profile to minimize rack space usage Note Design and specifications subject to change without prior notice 206 4157 7 Rear and
26. peat steps 4 to 7 e To modify the DNS configuration continue with step 9 e If no additional network configuration is required go to step 10 9 To change the DNS configuration type dns and press Enter At each of the following prompts type the information requested Press Enter after each entry Configuring DNS Primary DNS IP address Type both the primary and secondary DNS Secondary DNS IP address IP addresses in the format xxx xxx xxx xxx Once you enter the secondary DNS IP address the system will redisplay the Network Configuration Menu You can select another option to modify see previous steps or you can exit as described below Continued on next page 206 4157 17 PCS150R Configuration Options Cont Continued from previous page 10 When you are finished with network configuration type exit at the Network Configuration 11 Menu gt prompt The system will display an overview of the new network configuration and then prompt for confirmation to save the changes for example New Network Configuration Interface eth0 Host name pes150r Using DHCP YES Interface ethl Host name pcs150r Using DHCP YES DNS servers Primary DNS 68 94 156 1 Secondary DNS 68 94 157 1 Do you want to save the new configuration Y N Type y or n and press Enter as appropriate If you opt NOT to save the new configuration the system will return immediately to the Main Menu Command gt prompt
27. t it also does not cover damage due to misuse abuse negligence acts of God or other causes beyond the control of LG Any alteration of the product after manufacture voids this warranty in its entirety THIS WARRANTY IS IN LIEU OF ANY OTHER WARRANTY EXPRESS OR IMPLIED INCLUDING WITHOUT LIMITATION ANY WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE AND LG SHALL NOT BE LIABLE FOR ANY CONSEQUENTIAL INDIRECT OR INCIDENTAL DAMAGES OF ANY KIND INCLUDING LOST REVENUES OR PROFITS IN CONNECTION WITH THIS PRODUCT SOME STATES DO NOT ALLOW LIMITATIONS ON HOW LONG AN IMPLIED WARRANTY LASTS OR THE EXCLUSION OR LIMITATION OF INCIDENTAL OR CONSEQUENTIAL DAMAGES SO THE ABOVE LIMITATIONS OR EXCLUSIONS MAY NOT APPLY TO YOU OWNER S RESPONSIBILITY Effective Warranty Date Warranty begins on the date of delivery of the PCS150R Pro Centric Server For your convenience keep the dealer s dated bill of sale or delivery ticket as evidence of the purchase date Installation Guide Read the Installation amp Setup Guide carefully so that you will understand the operation of the PCS150R Pro Centric Server and how to adjust the settings Warranty Service For warranty service information call 1 888 865 3026 Parts and service labor that are LG s responsibility see above will be provided without charge Other service is at the owner s expense If you have any problem in obtaining satisfactory warranty service call 1 888 865 3026 You must
28. t additional equipment may be required to adjust the signal level 9 Configure the ASI or RF output parameters in the Pro Centric Server Admin Client Refer to the Pro Centric Server Admin Client User Guide for further information Note By default the server output is enabled for QAM B modulation RF output 12 206 4157 PCS150R Configuration Options This section describes configuration options for the PCS150R Note Before you proceed with any additional server configuration the system should be installed and operating as described in the system setup procedure on pages 11 and 12 Also note that configuration updates will generally require that you reset the PCS150R Make sure to reset the unit when directed to do so Network and Communication Options There are two options for establishing communication with the PCS150R Direct connection to the PCS150R RS 232 port Connect a PC to the RS 232 port on the PSC150R rear panel using a DB9 Male to DB9 Female RS 232 straight through serial cable Example Cables Unlimited PCM 2100 06 serial cable and if necessary a USB 2 0 to serial DB9 adapter Example Cables Unlimited USB 2920 adapter Using HyperTerminal or an equivalent terminal emulation program on the PC configure the serial port as follows Bits per second 115200 Data bits 8 Parity None Stop bits 1 Flow Control None Network connection to the PCS150R Ethernet port Use an SSH client
29. to establish communication with the PCS150R The default network setting for the PCS150R is DHCP in which case the server assigns an IP address to the PCS150R If necessary consult the network administrator to obtain the IP address that has been assigned to the PCS150R Log In to the PCS150R If necessary consult the network administrator to obtain the admin user password before proceeding 1 Establish communication with the PCS150R using one of the communication options described above Once communication is established you should see a login prompt 2 Atthe pcs150r login prompt type admin and press Enter 3 Atthe Password prompt type the admin password and press Enter 4 Atthe Command gt prompt either e Press Enter to display the PCS150R Main Menu see example on following page Type the desired command and press Enter The following sections describe each of the configuration commands 206 4157 13 PCS150R Configuration Options Cont Example PCS150R Main Menu update updser vpn reset exit Command gt System information Configure video parameters Setup TCP IP Timezone setup Change password Note You can always press Enter atthe Command gt prompt Upate to display the Main Menu Update via serial link VPN setup Reset board End the session View System Information 1 Log in to the PCS150R as described on the previous page 2 Atthe Command gt prompt type info and press
30. vapeddy Copyright 1994 Phil Karn Copyright 1996 1998 2003 William Allen Simpson Copyright 2003 Peter Stuge Copyright 2005 Reyk Floeter Copyright 1991 Massachusetts Institute of Technology Copyright 2004 Ted Unangst and Todd Miller Copyright 1999 WIDE Project Copyright 1996 Internet Software Consortium Portions Copyright 1999 2001 Internet Software Consortium Portions Copyright 1993 Digital Entertainment Cor poration Portions Copyright 1995 International Business Machines Inc e OpenSSL 1 0 0 Copyright 1998 2008 The OpenSSL Project Copyright 1995 1998 Eric Young All rights reserved Permission is hereby granted free of charge to any per son obtaining a copy of this software and associated doc umentation files the Software to deal in the Software without restriction including without limitation the rights to use copy modify merge publish distribute sublicense and or sell copies of the Software and to permit persons to whom the Software is furnished to do so subject to the following conditions SUBJECT TO THE TERMS OF THE GPL VERSION 2 0 LGPL VERSION 2 1 LICENSE AGREEMENTS THE SOFTWARE IS PROVIDED AS IS WITHOUT WARRANTY OF ANY KIND EXPRESS OR IMPLIED INCLUDING BUT NOT LIMITED TO THE WARRANTIES OF MERCHANTABILITY FITNESS FOR A PARTICULAR PURPOSE AND NONINFRINGEMENT IN NO EVENT SHALL THE AUTHORS COPYRIGHT HOLDERS OR LG ELECTRONICS THE LICENSOR BE LIABLE
31. ww LGsolutions com products From the Products page select TVs Systems amp Solutions then Head End Systems then Pro Centric Server click Show to view the list of products then PCS150R Click the Literature amp Downloads tab at the bottom of the PCS150R page and select the required document s from the Downloads list Notes 24 206 4157 Open Source Software Notice The following GPL executables and LGPL libraries used in this product are subject to the GPL Version 2 0 LGPL Ver sion 2 1 License Agreements GPL EXECUTABLES Linux kernel 2 6 33 LTIB 10 1 1 bash 2 05b busybox 1 1 3 e2fsprogs 1 34 ethtool 3 gawk 3 1 3 Irzsz_0 12 21 Izo 2 03 mtd utils 1 2 0 net tools 1 60 ntpclient_2003_ 194 openvpn 2 1 1 pciutils 2 1 11 ppp 2 4 1 procps 3 1 11 screen 4 0 2 1 skell 1 13 time 1 7 LGPL LIBRARIES eglibc 2 8 libelf 0 8 5 termcap 2 0 8 LG Electronics offers to provide source code to you on CD ROM for a charge covering the cost of performing such distribution such as the cost of media shipping and handling upon e mail request to LG Electronics at open source lge com This offer is valid for a period of three 3 years from the date of the distribution of this product by LG Electronics You can obtain a copy of the GPL LGPL licenses from http www gnu org licenses old licenses gpl 2 0 html and http www gnu org licenses oldlicenses lgpl 2 1 html This product includes e OpenSSH 4 3p2 Copyright
32. you to reset the PCS150R If necessary reset the server see Reset the PCS150R on page 22 Update the VPN Setup This option enables you to update the VPN client via a serial link to the PCS150R The appropriate update file must be provided by LG The system will not transfer an improper file 1 Log in to the PCS150R as described on page 13 2 Atthe Command gt prompt type vpn and press Enter The system prompts for the file Send VPN client file using Xmodem 3 At the system prompt transfer the new VPN client file using Xmodem protocol For example in HyperTerminal select Transfer and then Send File In the Send File window enter or select the appropriate filename in the Filename field and select Xmodem in the Protocol field Continued on next page 206 4157 21 PCS150R Configuration Options Cont Continued from previous page The system will display progress messages as well as the result of the update process which may take several minutes 4 When the update is successfully completed the system may prompt you to reset the PCS150R If necessary reset the server see Reset the PCS150R below Reset the PCS150R 1 If not already logged in log in to the PCS150R as described on page 13 2 Atthe Command gt prompt type reset and press Enter The reset will be initiated immediately After reset the PCS150R resumes normal operation Logout At the Command gt prompt type exit a

Download Pdf Manuals

image

Related Search

Related Contents

EH-KA15/25 (2.89 MB/PDF)  Gateway KNX/DMX KXDMXI  Samsung C61RCCN Käyttöopas  FBA スキャン納品説明書  BCDI, mode d`emploi Sur le bureau de l`ordinateur, l`icône de BCDI  New Template French  2015 Toyota Tacoma eBrochure (Español)  Panasonic Arbitrator 360 Operating Instructions  Philips 8718291657019 energy-saving lamp  iZotope Trash 2 Help Documentation  