1. 12h is an AM PM mode and 24h is military time Press the SET button 2 times TIME will flash in the upper left corner Press the INDOOR button to set the hours and press the OUTDOOR button to set the minutes 5 Press the SET button to activate the clock Note There is only a PM display which appears under TIME If there is no display here it is AM Make sure you set the time accordingly I UNITS OF TEMERA TURE MEASURE A SELECTING UNITS OF MEASUREMENT 1 Press and hold the SET button for 1 second 2 Press the SET button again F will appear in the TIME LCD 3 Press the IVDOOR button to shift between F and C 4 Press the SET button twice to activate settings IV FEATURES A INDOOR MINIMUM AND MAXIMUM TEMPERATURES 1 Press and hold the INDOOR button for 1 second MIN appears in the INDOOR LCD and the recorded minimum temperature is displayed Press and hold the INDOOR button for 1 second MAX appears in the INDOOR LCD and the recorded maximum temperature is displayed Note When first setting up the minimum and maximum temperatures may be the same as the current temperatures 3 To return to the current temperature press and hold the INDOOR button for 1 second B OUTDOOR MINIMUM AND MAXIMUM TEMPERATURES 1 Press and hold the OUTDOOR button for 1 second MIN appears in the OUTDOOR LCD The OUTDOOR MIN and T
2. 14 F to 140 F 10 C to 60 C Measuring Temperatures Temperature Station Indoor 20 2 F to 156 2 F with 0 2 F resolution 29 0 C to 69 0 C with 0 1 C resolution Temperature Station Outdoor 21 8 F to 156 2 F with 0 2 F resolution 29 9 C to 69 0 C with 0 1 C resolution 29 Remote Control Sender 21 8 F to 156 2 F with 0 2 F resolution 29 9 C to 69 0 C with 0 1 C resolution Accuracy Indoor 2 F 1 C Outdoor H 2 F 4 1 C Transmitting range of the Remote Control Sender Maximum 80 feet 25m Temperature check Indoor Temperature Station Indoor Every 10 seconds Indoor Temperature Station Outdoor Three minutes times in 10 Remote Control Sender LCD Once every minute Batteries Alkaline recommended Remote Control Sender 2 x AAA 1 5V Indoor Temperature 2 x AA 1 5V Station 30 Battery life expectancy for both units Approximately 1 year Dimensions L x W x H Indoor Station Temperature 3 51 x 1 19 x 4 88 in excluding table stand 90 x 30 5 x 125 mm Remote Control Sender 2 18 x 0 94 x 3 12 in 56 x 24 x 80 mm 31 WARRANTY INFORMATION La Crosse Technology Ltd provides a 1 year limited warranty on this product against manufacturing defects in materials and workmans
3. MOUNTING WITH ADHESIVE TAPE a b With a nonabrasive solution clean and dry the back of the mounting bracket and the mounting surface to ensure a secure hold The mounting surface should be smooth and flat Remove the protective strip from one side of the tape Adhere the tape to the designated area on the back of the mounting bracket 15 c Remove the protective strip from the other side of the tape Position the Remote Control Sender in the desired location ensuring that the Indoor Temperature Station can receive the signal B THE INDOOR TEMPERATURE STATION Note Before mounting the Indoor Temperature Station make sure that it is able to receive signals from the Remote Control Sender The Indoor Temperature Station can also be mounted in two ways e with the table stand or e on the wall with the use of a wall hanging screw not included 16 1 USING THE TABLE STAND a The Indoor Temperature Station comes with the table stand already mounted If you wish to use the table stand all that is required is to place the Indoor Temperature Station in an appropriate location 2 WALL MOUNTING a Remove the table stand To do this pull down on the stand from the rear and rotate forward b Fix a screw not included into the desired wall leaving approximately 3 16 of an inch 5mm extended from the wall c Place the Indoor Temperature Station onto the screw using the hanging hole on t
4. Technology Ltd authorized service center La Crosse Technology Ltd will pay ground return shipping charges to the owner of the product to a USA address only Your La Crosse Technology Ltd warranty covers all defects in material and workmanship with the following specified exceptions 1 damage caused by accident unreasonable use or neglect including the lack of reasonable and necessary maintenance 2 damage occurring during shipment claims must be presented to the carrier 3 damage to or deterioration of any accessory or decorative surface 4 damage resulting from failure to follow instructions contained in your owner s manual 5 damage resulting from the performance of repairs or alterations by someone other than an authorized La Crosse Technology Ltd authorized service center 6 units used for other than home use 7 applications and uses that this product was not intended or 8 the products inability to receive a signal due to any source of interference This warranty covers only actual defects within the product itself and does not cover the cost of installation or removal from a fixed installation normal set up or adjustments claims based on misrepresentation by 33 the seller or performance variations resulting from installation related circumstances LA CROSSE TECHNOLOGY LTD WILL NOT ASSUME LIABILITY FOR INCIDENTAL CONSEQUENTIAL PUNITIVE OR OTHER SIMILAR DAMAGES ASSOCIATED WITH THE OPERATION OR MAL
5. battery cover With the screw pull the battery cover off Observing the correct polarity install 2 AAA batteries The batteries will fit tightly make sure they do not spring free or start up problems may occur Check the LCD screen of the Remote Control Sender to see if there is a temperature reading If there is no reading check the polarity of the batteries or replace with new batteries Observing that the rubber weather seal is in place replace battery cover screw and mounting bracket B INDOOR TEMPERATURE STATION Note After the batteries are installed DO NOT press any buttons This may interfere with the signals causing temperatures to register incorrectly 1 Remove the battery cover on the backside To do this push up and pull out Battery Cover W Observing the correct polarity install 2 AA batteries Replace battery cover Wait 5 6 minutes or until both indoor and outdoor temperatures are shown on the Indoor Temperature Station The Indoor Temperature Station should now show in the TIME LCD and temperatures in the INDOOR and OUTDOOR LCD s TME ela TIME LCD INDOOR T INDOOR LCD gt T OUTDOOR LCD Yds Il TIME Control Buttons INDOOR OUTDOOR RESET 0000 A SETTING THE TIME l Press and hold the SET button for 1 second 12h will appear in the TIME LCD Use the INDOOR button to select either 12h time or 24h time
6. polarity The batteries may be weak replace with new batteries The Remote Control Sender may be out of its 80 foot 25m range bring the units closer together 24 _ appears in the OUTDOOR LCD of the Indoor Temperature Station continued Obstacles such as walls concrete metal window frames or large metal objects may be obstructing signal transmission from the Remote Control Sender Relocate the Remote Control Sender within range where there are no obstructions Other equipment in vicinity operating on 433MHz may interfere with signal turn off other equipment or relocate Indoor Temperature Station wait a few minutes for signal to be found Temperature exceeds range of the Remote Control Sender see specifications for range 25 No temperature in the LCD of the Remote Control Sender The batteries may be inserted wrong or weak check the polarity of batteries or replace with new batteries Remote Control Sender out of its 80 foot 25m range bring the units closer together If problem persists contact La Crosse Technology for replacement The LCD of the Indoor Temperature Station is blank Check for proper battery installation The batteries may be weak replace with new batteries 26 The LCD of the Indoor Contact La Crosse Technology for replace
7. FUNCTION OF THIS PRODUCT THIS PRODUCT IS NOT TO BE USED FOR MEDICAL PURPOSES OR FOR PUBLIC INFORMATION THIS PRODUCT IS NOT A TOY KEEP OUT OF CHILDREN S REACH This warranty gives you specific legal rights You may also have other rights specific to your State Some States do no allow the exclusion of consequential or incidental damages therefore the above exclusion of limitation may not apply to you For warranty work technical support or information contact La Crosse Technology 2809 Losey Blvd S La Crosse WI 54601 Phone 608 782 1610 Fax 608 796 1020 e mail 34 support lacrossetechnology com warranty work sales lacrossetechnology com information on other products web www lacrossetechnology com FCC DISCLAIMER This device complies with part 15 of the FCC rules Operation is subject to the following two conditions 1 this device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation Freq 433 92 MHz La Crosse Technology Made in China WS7016U 35
8. IME displays will flash The recorded minimum temperature is displayed in the OUTDOOR LCD and the time it was recorded is displayed in the TIME LCD After 15 seconds the OUTDOOR MIN and TIME will stop flashing However the minimum outdoor temperature will continue to be displayed Press and hold the OUTDOOR button for 1 second MAX appears in the OUTDOOR LCD The OUTDOOR MAX and TIME displays will flash The recorded maximum temperature is 10 displayed in the OUTDOOR LCD and the time it was recorded is displayed in the TIME LCD After 15 seconds the OUTDOOR MAX and TIME will stop flashing and the maximum outdoor temperature will continue to be displayed To return to current temperature press and hold the OUTDOOR button for 1 second V RESETTING THE MINIMUM AND MAXIMUM TEMPERA TURES A INDOOR 1 To reset both the minimum and maximum temperatures press and continue to hold the IVDOOR button while you press and hold the RESET button When the 11 temperatures are reset release the buttons To return to the current indoor temperature press and hold the INDOOR button two times holding for 1 second each B OUTDOOR 1 To reset both the minimum and maximum temperatures press and continue to hold the OUTDOOR button while you press and hold the RESET button When the temperatures are reset release the buttons To return to the current outdoor t
9. MENT not included 1 2 3 4 1 Philips screwdriver 1 Flat screwdriver 2 Fresh AA 1 5V batteries 2 Fresh AAA 1 5V batteries QUICK SETUP 1 2 4 5 Insert two AAA batteries into the Remote Control Sender Insert two AA batteries into the Indoor Temperature Station Wait 5 6 minutes or until the outdoor temperature is displayed in the OUTDOOR LCD Liquid Crystal Display of the Indoor Temperature Station Set the Time See complete instructions for details Mount units Note The Remote Control Sender transmits a signal every 3 minutes After the batteries have been installed the Indoor Temperature Station searches for these signals for a duration of 6 minutes If there is no temperature reading in the OUTDOOR LCD after 6 minutes make sure the units are within range of each other or repeat battery installation process DETAILED SETUP GUIDE I BATTERY INSTALLATION A REMOTE CONTROL SENDER Battery cover i Battery compartment 1 Remove the mounting bracket The bracket snaps on and off with minimal effort 2 Remove battery cover To do this remove the flathead screw located in the lower central position of the unit The rubber weather seal creates a tight seal for the battery cover and does not allow the 3 battery cover to fall away from the unit Place the screw partially back into the hole and angle it slightly so the threads grab the
10. WS 7016U Wireless 433 MHz Temperature Station Instruction Manual Ms LA CROSSE TECHNOLOGY TABLE OF CONTENTS Topic Page Inventory of Contents 1 Additional Equipment 1 Quick Setup 2 Detailed Setup Guide Battery Installation 3 6 Remote Control Sender 3 4 Indoor Temperature Station 5 6 Setting the Time 7 8 Selecting Units of Measurement 8 Features Indoor Minimum and Maximum 9 Temperatures Outdoor Minimum and 10 11 Maximum Temperatures Resetting the Indoor Minimum 11 12 and Maximum Temperatures Resetting the Outdoor Minimum 12 and Maximum Temperatures Reading the Temperature Trend 13 Mounting Remote Control Sender 13 16 Indoor Temperature Station 16 18 Using Multiple Remote Control Senders Setup of Multiple Units 18 21 Viewing Remote Control 21 22 Senders Features of the Multiple Remote 22 23 Control Senders Troubleshooting 24 28 Maintenance and Care Instructions 28 29 Specifications 29 31 Warranty Information 31 33 FCC DISCLAIMER 34 iii INVENTORY OF CONTENTS 1 The Indoor Temperature Station Figure 1 2 The Outdoor Remote Control Sensor TX3U and mounting bracket Figure 2 3 3 each 1 2 Philips screws 4 One strip of double sided adhesive tape 5 Instruction Manual and Warranty Card Figure 1 BAE M Figure 2 ADDITIONAL EQUIP
11. emperature press and hold the OUTDOOR button two times holding for 1 second each 12 VI READING THE TEMPERA TURE TREND A The temperature trend indicator is displayed in the OUTDOOR LCD 1 A Indicates that the temperature is rising 2 W Indicates that the temperature is dropping 3 The absence of an arrow indicates that the temperature is stable VIL MOUNTING A THE REMOTE CONTROL SENDER Note To achieve a true temperature reading avoid mounting where direct sunlight can reach the Remote Control Sender We recommend that you mount the Sender on a North facing wall The sending range is 80ft obstacles such as 13 walls concrete and large metal objects can reduce the range Place both units in their desired location before permanently mounting the Remote Control Sender There should be a change of temperature in the OUTDOOR LCD within 6 minutes The Remote Control Sender can be mounted in two ways e with the use of screws or e using the adhesive tape 1 MOUNTING WITH THE SCREWS a Remove the mounting bracket from the Remote Control Sender figure 2 b Place mounting bracket over desired location Through the three screw holes of the bracket mark the mounting surface with a pencil 14 c d Where marked drill holes into mounting surface using an appropriate size drill bit Screw mounting bracket onto the mounting surface Ensure that the screws are flush with the bracket
12. he backside Gently pull the Station down to lock the screw into place VIN USING MULTIPLE REMOTE CONTROL SENDERS Your WS 7016U Indoor Temperature Station can receive signals from five different Remote Control Senders The TX3U features temperature data transmission and the TX3UP 18 offers the same plus a 10 probe to insert in a pool spa soil etc Assign a number to each Remote Control Sender i e 1 will be for outdoors 2 will be for the basement etc This will help you determine which temperature from which Sender you are reading on the Indoor Temperature Station Note When setting up multiple units it is important to insert batteries first into all the Remote Control Senders and in numeric sequence Second install batteries into the Indoor Temperature Station Transmission problems will arise if this is not done correctly and if the total time for set up exceeds 6 minutes 19 A SETUP OF MULTIPLE UNITS 1 It is necessary to remove the batteries from all existing units in operation 2 Remove the battery covers to all Remote Control Senders See section I A 2 3 Place all Remote Control Senders in sequential order REMOTE CONTROL SENDER REMOTE CONTROL REMOTE CONTROL SENDER SENDER 4 In sequential order install batteries Refer to instructions in I A 3 through I A 5 20 Install batteries into the Indoor Temperature Station Refer to instructions in I B Follow directions
13. hip This limited warranty begins on the original date of purchase is valid only on products purchased and used in North America and only to the original purchaser of this product To receive warranty service the purchaser must contact La Crosse Technology Ltd for problem determination and service procedures Warranty service can only be performed by aLa Crosse Technology Ltd authorized service center The original dated bill of sale must be presented upon request as proof of purchase to La Crosse Technology Ltd or La Crosse Technology Ltd s authorized service center La Crosse Technology Ltd will repair or replace this product at our option and at no charge as stipulated herein with new or reconditioned parts or products if found to be defective during the limited warranty period specified above All replaced parts and products become the property of La Crosse Technology Ltd and must be returned to La Crosse Technology Ltd Replacement parts and products assume the remaining original warranty or ninety 90 days whichever is longer La Crosse Technology Ltd will pay all expenses for labor and materials for all repairs 32 covered by this warranty If necessary repairs are not covered by this warranty or if a product is examined which is not in need or repair you will be charged for the repairs or examination The owner must pay any shipping charges incurred in getting your La Crosse Technology Ltd product to a La Crosse
14. in section ILA to set the time section III A to select Fahrenheit or Celsius and section VII A to mount B VIEWING MULTIPLE REMOTE CONTROL SENDERS ON THE INDOOR TEMPERATURE STATION 1 To view the temperature of a different Remote Control Sender press the RESET button In the OUTDOOR LCD a should shift and become a This indicates that you are now reading the temperature of the Remote Control Sender you designated as 2 21 Repeat step 1 to view the 3 4 and 5 depending on how many are set up temperatures sent by the Remote Control Senders Continue to press RESET until you return to the first Remote Control Sender C VIEWING THE FEATURES OF MULTIPLE REMOTE CONTROL SENDERS 1 Press the RESET button to select the Remote Control Sender you wish to view To view the OUTDOOR MINIMUM AND MAXIMUM TEMPERATURES follow directions in section IV B While in this mode press the RESET button to toggle through different Remote Control Senders and view 22 their minimum and maximum temperatures To reset the OUTDOOR MINIMUM AND MAXIMUM TEMPERATURES follow step 1 above and the directions in sections V A through V B This will reset the minimum and maximum for only the selected Remote Control Sender 23 TROUBLESHOOTING Problem Solution appears in the OUTDOOR LCD of the Indoor Temperature Station Batteries may be inserted wrong in Remote Control Sender correct the
15. ment Temperature Station is blank continued Temperature is Temperatures can vary incorrect depending on the location of the Remote Control Sender The thermometers are not 100 accurate the WS 7016U is accurate to 2 F If you are sure the temperature is wrong the unit reads 110 F when it is actually 70 F reset entire system by removing all batteries and following set up instructions If this does not solve the problem contact La Crosse Technology for replacement 27 Problem not Call La Crosse Technology to covered under order replacement part We the warranty ie will accept Visa MasterCard Dropped unit Discover or prepayments by into water check MAINTENANCE AND CARE INSTRUCTIONS e Extreme temperatures vibration and shock should be avoided to prevent damage to the units e Clean displays and units with a soft damp cloth Do not use solvents or scouring agents they may mark the displays and casings e Do not submerge in water e Do not subject the units to unnecessary heat or cold by placing them in the oven or freezer 28 e Opening the casings invalidates the warranty Do not try to repair the unit Contact La Crosse Technology repairs SPECIFICATIONS Transmitting Frequency 433MHz Recommended Operating Temperature Indoor Temperature Station 32 F to 122 F 0 C to 50 C Remote Control Sender