1. NENNLEISTUNG LAMPEN LAMPS POWER PUISSANCE LAMPES POTENCIA NOM DAS LAMPADAS POTENZA LAMPADINE VERMOGEN LAMP LAMPOR POTENTIAL F PTX Tec Cod Technical Code Network Code V Network Frecuency Hz Dis LISTED ELECTRIC FAN XXXX Lights gra Power Motor Volume 22UL3241S 120 60 2x20 340 850 m h KUPPERSBUSCH reserves the right to make changes and corrections to its products as it deems necessary without altering their basic characteristics Accesories supplied 150 125 mm reduction Anti recoil valve 6 Lock screws 8 x 45 Grounding Instructions This appliance must be grounded In the event of an electrical short circuit grounding reduces the risk of electric shock by providing an escape wire for the electric current This appliance is plugged into an outlet that is properly installed and grounded WARNING Improper grounding can result in a risk of electric shock Consult a qualified electrician if the grounding instructions are not completely understood or if doubt exists as to whether the appliance is properly grounded Do not use an extension cord If the power supply cord is too short have a qualified electrician install an outlet near the appliance Manual ND ISLA UL ing gxd 6 05 2003 11 5 Installation On installing the kitchen hood make sure that the Safety Instructions set out on page 2 are complied with e WARNING TO REDUCE THE RISK OF FIRE
2. e g while they are being cleaned in the dishwasher _ e We recommend the use of gloves and to be Bescrl plonoutbelap parts extremely careful when cleaning the kitchen kala A Electronic programmer control box with e Your kitchen hood is designed for domestic buttons to control speed light and use and only for extraction and purification power in use indicators of gases produced during food preparation i It will be your responsibility if it is used for B Metal filters other purposes which may be dangerous C Lamp with two lights 20 W G 4 The manufacturer cannot accept responsi D E Vertically adjustable tubecovers bility for damage caused by improper use of the apparatus F Decorative part No incluided e For repairs please contact the nearest KUPPERSBUSCH Technical Assistance Service and always use genuine spare parts Repairs or modifications effected by unqualified personnel can cause malfunctions or may damage the apparatus putting your safety in danger 3 ENG Manual ND ISLA UL ing gxd ENG 6 05 2003 11 5 Instructions for use You may control the kitchen hood s workings by operating the controls as shown in the diagram 20min 10min 5min Light Minimum speed Medium speed Maximum speed Timer To improve draught we recommend to turn the extractor fan on a few minutes before cooking so that the flow of air is continuous and stable when fumes are extracted Similarly keep the ext
3. ELECTRIC SHOCK OR INJURY TO PERSONS OBSERVE THE FOLLOWING a Installation work and electrical wiring must be done by qualified person s in accordance with all applicable codes and standards including fire rated construction b Sufficient air is needed for proper combustion and exhausting of gases through the flue chimney of fuel burning equipment to prevent back drafting Follow the heating equipment manufacturer s guideline and safety standards such as those published by the National Fire Protection Association NFPA and the American Society for Heating Refrigeration and Air Conditioning Engineers ASHRAE and the local code authorities c When cutting or drilling into wall or ceiling do not damage electrical wiring and other hidden utilities d Ducted fans must always be vented to the outdoors e WARNING TO REDUCE THE RISK OF FIRE USE ONLY METAL DUCTWORK e WARNING To Reduce The Risk Of Fire Or Electric Shock Do Not Use This Fan With Any Solid State Speed Control Device To obtain optimum performance the external conduct must not be more than FOUR METRES LONG have more than two 90 angles and its diameter must be at least 2120 P gina 7 Installation with output vent Fig 1 Pag 8 1 Using the support 0 trace and drill the points for fitting the lock screws S 98 x 45 onto the ceiling 2 Screw the support 0 into the ceiling with the lock screw S 28 x 45 3 Mount the to
4. Manual ND ISLA UL ing gxd 6 05 2003 set P gina 1 INSTRUCTIONS FOR USE AND INSTALLATION INSTRUCTIONS JAN TKD 1157 1 GE UL K ppersbusch ALLERFEINSTE K CHENTECHNIK Manual ND ISLA UL ing gxd ENG 6 05 2003 11 5 Dear client Congratulations on your choice We are sure that this modern functional and practical apparatus made with top quality materials will fully satisfy your needs Please read every section of this INSTRUCTIONS MANUAL before using your kitchen hood for the first time to be able to get maximum performance from the apparatus and to avoid breakdowns which may be caused by incorrect use as well as to allow any minor problems to be solved Store this manual as it will provide useful information about your kitchen hood at all times and will also help other people to use it Important Safety Instructions READ AND INSTRUCTIONS e Take care when using cleaning agents or detergents SAVE THESE e Suitable for use in household cooking area e CAUTION To reduce risk of fire and to properly exhaust air be sure to duct air outside Do not vent exhaut air into spaces within walls or ceiling or into attics crawl spaces or garages e CAUTION For General Ventilating Use Only Do Not Use To Exhaust Hazardous Or Explosibe Materials And Vapors e WARNING TO REDUCE THE RISK OF FIRE ELECTRIC SHOCK OR INJURY TO PERSONS OBSERVE THE FOLLOWING a Use this unit only in the manner in
5. isher and you already know how to operate it 2 The fire is small and contained in the area where it started 3 The fire department is being called 4 You can fight the fire with your back to an open exit Please be aware of current local regulations with reference to domestic electrical fittings and gas eduction Verify that the tension and frequency of the network match those indicated on the label located inside the kitchen hood h Manual ND ISLA UL ing gxd 6 05 2003 11 5 P amp gina 3 Index e Once the kitchen hood has been installed ensure that the feed cable to the network is Page not in contact with any live metal edges e Avoid connecting the apparatus to Deseription ot the apparatus 3 conductors used exits for fumes produced Instructions for use 4 by a non electric energy source E g i boilers chimneys etc Programming timer 4 e If the extractor fan is going to be used Cleaning and maintenance 4 simultaneously with equipment powered by a non electric energy source E g gas Problem solving 5 cookers the room must have sufficient Sizes and specifications 5 ventilation e The lower part of the kitchen hood must be Accessories supplied 6 fitted at least 60 cm 23 6 in over electric Grounding instructions 6 hobs and 65 cm 25 6 in over gas or mixed hobs Installation 7 e Avoid cooking under the kitchen hood ifthe Active charcoal filters 8 metal filters are not fitted
6. ith a clamp not supplied 11 Mount the bottom group to the top fixed to the ceiling with the screws A10 M4 x 12 P gina 9 to the desired height 12 Mount the part A5 with the screws A4 M4 x 12 in the rectangle parts of the top inner body A6 13 Lift the upper tubecover A8 up to the desired height and fix it to the top group with the screws G M4 x 12 flat head 14 Adjust finally the decorative glass part U fixing it to the body of the kitchen hood using the screws V M4 provided with the glass 15 Put the filters into the lateral draught section of the motor making the holes in the filters match up A11 with the pivots A12 of the motor carcass ENG
7. p inner body A6 in the support O with the screws Q M6 x 16 4 Softly attach the decorative handle W to the decorative glass part U with the screws X M5 and the washers Y provided with the glass 5 Adjust the decorative glass part U fixing it to the body of the kitchen hood using the screws V M4 provided with the glass 6 Fit the part A if the inner tube not supplied is 2150 or A B if it is 9120 7 Attach the inner tube with a clamp not supplied to A or B as the case may be 8 Introduce the upper tubecover A8 into the lower tubecover A9 9 Adjust the group lower tubecover A9 and upper tubecover A8 to the bottom inner body A7 and to the decorative glass wing U 10 Mount the bottom group to the top fixing it to the ceiling with the screws A10 M4 x 12 to the desired height 11 Fit the top part of the inner tube not supplied to the output vent 12 Lift the upper tubecover A8 up to the desired height and fix it to the top group with the screws G M4 x 12 flat head 13 Adjust finally the decorative glass part U fixing it to the body of the kitchen hood using the screws V M4 provided with the glass h ENG Manual ND ISLA UL ing qxd ENG 6 05 2003 11 5 P gina 8 Installation witouth output vent with active charcoal filters Optional When exterior gas extraction to the outside is not possible then the kitchen hood may be
8. ractor fan on for a few minutes after cooking to completely extract fumes and odours Programming timer 1 By pressing for more than 2 seconds any speed the kitchen hood will stay switched on for 10 minutes at the selected speed To program a duration other than 10 minutes a With the kitchen hood switched off press timer b Select the required programming time by pressing the chosen button see drawing c Press timer again to record the new program d Press the chosen speed for more than 2 seconds the pilot light will start flashing P gina 4 Cleaning and maintenance When cleaning and doing maintenance make sure the safety instructions set out on page 2 are complied with Cleaning the body of the kitchen hood e f your kitchen hood is made from stainless steel use this material s specially designed cleaners following the instructions mentioned in the product supplier s instructions e Never use metallic scourers nor abrasive or corrosive products e Dry the kitchen hood using a cloth that does not produce fluff Cleaning the meial filters To remove the filters from their fittings press lightly on the locks and then pull them off The metal filters can be cleaned by soaking them in hot water with neutral detergent until the fat dissolves and then rinsing them under the tap or using products specially designed for fats They can also be washed in a dishwasher In this case it i
9. s advisable to stack them vertically to avoid food residue sticking to them Cleaning in a dishwasher with aggressive detergents or polish may damage the metallic surface blackening it although this will not affect its fat retention capacity Once clean leave them to dry off and then fit them onto the kitchen hood Changing lights Proceed as follows e Unscrew the decorative element of the halogen lamp e Change the broken burnt out Maximum lamp power is 20 W G 4 lamp e Screw back on the decorative element of the halogen lamp h Manual ND ISLA UL ing gxd 6 05 2003 11 5 P gina 5 Problem solving Proceed with the following checks before calling the Technical Service The kitchen hood feed cable is not connected to Connect feed cable to the network The extractor fan ceases to function the network There is no electrical current in the network Check that the network has electrical current Filters are saturated with fat Change or clean the active charcoal and or metal The extractor ceases to educt strongly filters as the case may be or vibrates Obstruction in the air exit conduct Eliminate the obstruction The lamps are burnt out Change the lamps The lamps do not light up The lamps are loose Tighten the lamps Sizes and specifications ENG Manual ND ISLA UL ing gxd 6 05 2003 11 5 ENG P gina 6 K ppersbusch Mod IKD 1157 1 GE UL F Npitttttetet POTENGIA NOM LAMPARAS
10. set to purify the air by recycling it through active charcoal filters The active charcoal filters have an active life of between three to six months depending on the individual conditions of use These filters cannot be washed nor regenerated They must be replaced once their useful life comes to an end SET type 1 Fig 2 Page 9 1 Using the support 0 trace and drill the points for fitting the lock screws S 28 x 45 onto the ceiling 2 Screw the support O into the ceiling with the tirafondos anclaje S 98 x 45 3 Mount the top inner body A6 in the support O with the screws Q M6 x 16 4 Softly attach the decorative handle W to the decorative glass part U with the screws X M5 and the washer Y provided with the glass 5 Adjust the decorative glass part U carrefully fixing it to the body of the kitchen hood using the screws V M4 provided with the glass h Manual ND ISLA UL ing gqxd 6 05 2003 11 5 6 Fit the part A if the inner tube not supplied is 150 or A B if it is 9120 7 Attach the inner tube with a clamp not supplied to A or B as the case may be 8 Introduce the upper tubecover A8 into the lower tubecover AQ 9 Adjust the group lower tubecover A9 and upper tubecover A8 to the botton inner body A7 and to the decorative glass wing U 10 Fit the circular entrance of the part A5 to the top part of the inner tube not supplied w
11. tended by the manufactured If you have questions contact the manufacturer b Before servicing or cleaning the unit switch the power off at service panel and lock the service disconnecting means to prevent power form being switched on accidentally When the service disconnecting means cannot be locked securely fasten a prominent warning device such as a tag to the service panel P gina 2 WARNING TO REDUCE THE RISK OF A RANGE TOP GREASE FIRE a Never leave surface units unattended at high settings Boilovers cause smoking and greasy spillovers that may ignite Heat oils slowly on low or medium settings b Always turn hood ON when cooking at high heat or when cooking flaming foods c Clean ventilating fans frequently Grease should not be allowed to accumulate on fan or filter d Use proper pan size Always use cookware appropiate for the size of the surface element WARNING TO REDUCE THE RISK OF INJURY TO PERSONS IN THE EVENT OF A RANGE TOP GREASE FIRE OBSERVE THE FOLLOWING a SMOTHER FLAMES with a close fitting lid cookie sheet or metal tray then turn off the burner BE CAREFUL TO PREVENT BURNS If the flames do not go out inmediately EVACUATE AND CALL THE FIRE DEPARTAMENT b NEVER PICK UP A FLAMING PAN You may be burned c DO NOT USE WATER including wet dishcloths or towels a violent steam explosion will result d Use an extinguisher ONLY if 1 You know you have a Class ABC extingu