Home

Kubota 7780 User's Manual

image

Contents

1. AG 508CA 8x50mL Conicaltube 30x117 16 500 36 530 15 200 30 990 8x15mL Conical tube 17x121 16 500 35 920 15 200 30 480 Adaptor Code No 055 1250 is necessary AG 6512C gt 12x50mL Conical tube 30x117 11 500 21 000 11 500 21 000 12x15mL Conicaltube 17x121 11 500 17 590 11 500 17 590 50 mL conical tube PP with cap of 36 mm diameter or less made by BIO BIK CORNING FALCON GREINER IWAKI NUNC and SARSTEAD can be accommodated 35 mL Oak ridge conical tube PC PPCO made by NALGE NUNC is acceptable AG 508CA can accommodate 15 mL conical tubes PP made by BIO BIK CORNING FISHER and GREINER AG 6512C can accommodate 15 mL conical tube PP made by any company Plate Rotor Shield cover is useful for prevention against contamination Useful for DNA extraction amp purification ethanol precipitation purification of PCR product in PCR plate elimination of Dye terminator Max Size of Plate Max Speed Max RCF mm rpm xg RS 751GS 37 12x microplate 86 W x128 D x90 H 5 000 4 390 4x deepwell plate O Tray Code No 055 6380 is necessary with shield cover RS 745GS 9 12x microplate 4 x deepwell plate PUNKI DONE 4 200 3 100 O Tray Code No 055 6380 is necessary Tray Code No 055 6380 Optional with shield cover i i Sh kun KAA Deu RSS 12x 96 well plate 4x deepwell plate 4x squarewell plate 2 deepwell plate 2x PCR plate filter plate RMP 89G 8x microplate 4x deepwell plate DR
2. deceleration characteristics Acceleration and deceleration curves can be varied in three Steps according to the type of sample and experimental conditions Acceleration and or deceleration commencement speed can be selected for the sample easy to stir Density gradient method is also possible Acceleration deceleration characteristics graph rpm Speed Rapid deceleration Slow deceleration Super slow deceleration Super slow acceleration Newel elage i Slow acceleration Rapid acceleration Time e For the super slow acceleration and the super slow deceleration a characteristic change over speed Na and Nb can be set from 0 to 22 000 rpm e Natural deceleration starts at the change over speed Nb PROGRAM key TIME key TIME knob TIME display NORMAL key OPEN key OPEN lamp FLASHING key STOP key ACCEL key PROGRAM selection key START key High RCF 36 530 xg 21 000 xg Fixed Angle Rotor Cap support structure enables high g force centrifugation without tube breakage excluding AG 6512C Patent pending High g force enables separation of sticky protein Speed down or special tube is not necessary to prevent tube from breakage l At keeping 4 C _ Tube size nens epacl Mer I ye Goes Mac ICE diam x length mm rpm xg rpm xg showing maximum speed and RCF when keeping the sample at 4 C At the ambient temperature 25 C
3. the outer tube As to RCF of the inside please contact your local dealer 2 Sealing cap and sealing adaptor for bio hazard proof are available Please contact your dealer for details 3 Please confirm the delivery schedule with your dealer 4 RS 410G can accommodate sealing cap Code No S17111 optional 5 S17019 tube rack cannot be accommodated with the sealing cap Code No S13130 12x15 mL conical bucket can accommodate sealing cap Code No S17111 optional 6 175 mL conical tube is made by Falcon Catalog No 352076 and requires a cushion Catalog No 352090 200 mL conical tube is made by Nalge Nunc Catalog No 376813 and requires a cushion Catalog No 377585 225 mL conical tube is made by Falcon Catalog No 352075 and requires a cushion Catalog No 352090 7 Please check the strength of plates before using the centrifuge The plate at the bottom may be damaged 8 As to RCF display please refer to Instruction and Service manual 9 INSEPACK II 5 7 mL of Sekisui VENOJECT II 5 7 mL of Terumo NEOTUBE 5 7 mL of Nipro and VACUTAINER 5 7 mL of Beckton Dickenson can be used Model 7780 Maximum Speed e 22 000rpm Maximum RCF e 52 490xg Maximum Capacity e 4 000mL Control system Micro processor control Brushless motor Speed RCF Time g sec Temperature Acceleration 8 Deceleration 20 channel memories abnormality detected display Lid open Imbalance Over speed Abnormally high temperature Rotor mounting abnormality Funct
4. 114 0050 PSF 3115 0050 PC 3118 0050 PPCO 3119 0050 28 8x107 7 29 0x107 7 28 8x107 0 28 8x106 7 055 4510 250mL PPCO 3120 0250 61 8x127 7 AG 5004 11 000 20 160 Bottle PC 3122 0250 61 8x127 6 AG 5006 10 000 18 450 50mL 055 4290 Oak ridge type tube AG 1008A 15 500 34 110 O Adaptor is made of Polyathetale and the cap of acrylic FEP Teflon FEP PSF Polysulfone PC Polycarbonate PPCO Polypropylene copolymer 7mL 100mL Middle Volume Fixed Angle Rotor i At keeping 4 00 __ Tube size Max Speed Max RCF Max Speed Max RCF diam x length mm rpm xg rpm xg showing maximum speed and RCF when keeping the sample at 4 C At the ambient temperature 25 C AG 716 16x7mL 15 9 16 4x60 64 22 000 48 700 21 000 44 370 AG 1212 12x12mL 15 91 16 4x103 109 22 000 51 950 20 500 45 100 AG 1224 1 24x12mL 15 9 16 4x103 105 18 500 42 860 17 000 36 190 AG 506R 7 6x50mL 28 71 29x103 109 22 000 52 490 19 500 41 240 Tube adaptor is available for various capacities As for details please contact your dealer AG 508R 8x50mL 28 7 29x103 109 19 000 43 590 17 000 34 900 Tube adaptor is available for various capacities As for details please contact your dealer AG 1008A 8x100mL 38x114 15 500 35 190 14 000 28 710 Tube adaptor is available for various capacities As for details please contact your dealer RA 360G 24x15mL 16x126 3 500 2 270 3 500 2 270 Tube siz
5. 6 5 000 4 47008 S13130 28x10mL blood collecting tube 15mL 15 50 17x870 110 5 000 4 160 attached to rotor S17015 4x50mL 34x110 5 000 4 160 attached to rotor S17050 4x50mL 271 35 8x82 110 5 000 4 160 attached to rotor 055 5670 4x50mL Conical tube 29 5x117 5 000 4 160 attached to rotor S17049 4x100mL 44 45x110 5 000 4 160 attached to rotor S17100 4x200mL 56 5x104 5 000 4 160 attached to rotor RS 720G 80x2mL 9 50 11x360 42 3 500 2 29008 053 5820 055 4800 96x6mL RIA tube 100 12 3x65 95 3 500 2 1900 8 053 5820 055 4730 80x10mL 12 50 13 8x65 95 3 500 2 260 053 5820 055 4740 48x10mL blood collecting tube 15mL 150 17 2x81 110 3 500 2 330 053 5820 055 4750 68x5 7mL blood collecting tube o9 12 50 13 7x62 110 3 500 2 300 053 5840 055 0260 68x10mL blood collecting tube I5mL 150 17 2x52 110 3 500 2 300 053 5840 28x15mL Conical tube 17x121 3 500 2 300 053 5840 32x15mL Conical tube 17x121 3 500 2 330 053 5820 055 4780 8x50mL 270 36 4x85 110 3 500 2 330 053 5820 055 4760 16x50mL Conical tube 30x117 3 500 2 330 053 5820 055 6070 4x100mL 380 46 5x75 120 3 500 2 330 053 5820 055 4770 4x175mL Conical tube 0 68 61x118 3 500 2 330 053 5820 055 4850 4x200mL Conical tube co 6 8 61x130 3 500 2 330 053 5820 055 4850 4x225mL Conical tube n 6 8 61x137 3 500 2 330 053 5820 055 4850 4x250mL 60 61 8x100 130 3 500 2 38008 053 5820 055 4850 RS 1400GA 2 4x250 350mL 670 71x100 128 5 000 4 000 4 810 3 080 1 The RCF figure shows RCF of
6. AN 2 400 1 080 O Tray Code N0 055 6370 is available optional 250mL 1 000mL Large Volume Fixed Angle Rotor At keeping 4 Tube size Max Speed Max RCF Max Speed Max RCF diam x length mm rpm xg rpm xg showing maximum speed and RCF when keeping the sample at 4 C At the ambient temperature 25 C AG 2506 6x250mL 601 62 4x119 137 13 000 26 830 12 500 24 810 Tube adaptor is available for various capacities As for details please contact your dealer AG 5004 4x500mL 69 70 2x155 170 5 11 000 20 700 11 000 20 700 Tube adaptor is available for various capacities As for details please contact your dealer AG 5006 12 6x500mL 690 70 2x155 170 5 10 000 18 890 10 000 18 890 Tube adaptor is available for various capacities As for details please contact your dealer AG 1K4 52 4x1 000mL 95 5x198 5 9 000 15 760 9 000 15 760 Sealing adaptor for high speed fixed angle rotor Available for 10 ML and 50 mL Oak ridge type tubes and 250 mL bottles d Autoclavable 121 C D High Speed Rotor for 10mL Oak ridge type tube for 50mL Oak ridge type tube for 250mL bottle AG 506R AG 508R AG 10084 Code No 055 4280 Code No 055 4290 Code No 055 4510 AG 5004 AG 5006 1 Nominal Tube size Max Speed Max RCF FEP 3114 0010 16 0x81 5 10mL 16 0x82 0 AG 506R 22 000 49 240 PSF 3115 0010 055 4280 Oak ridge 16 1x81 7 AG 508R 19 000 41 170 ai PC 3118 0010 p PPCO 3119 0010 16 0x81 4 FEP 3
7. MSD High Speed Refrigerated Centrifuge e KUBOTA Max 22 000 rpm 52 490 xg Max 4 Liters KUEOTA Foot switch optiona The lid opens automatically when the switch is pressed A newly designed gas spring produces smooth and quick opening while hands free opening makes the experiments easier AG 1K4 Fixed Angle Rotor 4 x 1Liter Light weight made of Aluminium 30 less than AG 5006 6x500mL in weight H High Capacity Rotor Aluminium Rotor of 4 x 1 Liter at 15 760 xg E Auto Interlock Lid Lid can be opened closed using one hand e To close lid Push slightly and the lid locks automatically by an electrical interlock system To open lid Press the lid open key and the lid opens automatically after releasing the interlock A foot Switch optional also enables hands free lid opening Mi Easy to use and convenient functions e Memory flashing function for easy spin down Patent pending Automatically memorizes the duration of spin down operation ranging from 1 to 90 seconds Merely pressing the key the next time starts the spin down procedure for the memorized duration e Twenty 20 operation condition memory settings are available with one touch saving access and operation possible e Equipped with a tachometer port to comply with GMP reguirements Actual rotor speed is easy to check e Acceleration and deceleration curve can be varied in three Steps according to the type of sample and exp
8. e Max Speed Max RCF Bucket ee Rak diam x length mm rpm xg Code No a AG 224 24x2mL 9 50 11 0x36 42 22 000 44 370 24x0 5mL 7 01 7 9x25 34 22 000 39 500 055 7590 24x0 4 ML 5 4 6 1x26 48 22 000 43 830 055 7580 24x0 2mL PCR 5 9 6 3x20 24 15 000 16 100 055 0500 RA 159G 3 72x2mL 9 50 11 0x36 42 13 500 24 25001 72x0 5mL 7 01 7 9x25 34 13 500 24 0400 1 055 7590 72x0 AmL 5 4 6 1x26 48 13 500 23 6400 1 055 7580 72x0 2mL PCR 5 9 6 3x20 24 13 500 20 5800 1 055 0500 RS 35G swinging bucket rotor 16x2mL 9 50 11 0x36 42 15 000 18 360 053 5130 4x0 5 mL 7 01 7 9x25 34 15 000 16 100 053 5130 20x0 5mL 7 01 7 9x25 34 15 000 16 100 053 5140 36x0 4mL 5 4 6 1x26 48 15 000 18 360 053 5150 16x0 2mL PCR 5 9 6 3x20 24 15 000 11 820 053 5130 055 0500 Swinging Bucket Rotor RS 200G gt 4x50mL 28 71 29x103 109 11 500 20 700 Tube adaptor is available for various capacities As for details please contact your dealer RS 410G 3 Sealing cap is available and is biohazard proof Autoclavable 121 C 48x2mL 10 7x42 5 000 4 160 attached to rotor S17008 48x5mL RIA tube 12 5x55 75 5 000 4 160 attached to rotor S17006 48x7mML 12 12 5x100 112 5 000 4 160 attached to rotor S17007 28x7mL blood collecting tube 12 50 13x750 106 5 000 4 160 attached to rotor S17027 12x15mL Conical tube 0 5 16 5x120 6 5 000 4 160 attached to rotor S17019 12x15mL Conical tube 0 5 16 5x120
9. erimental conditions e RCF xg set operation function and stepped centrifugal force function Integrator function that can attain optimization of centrifuging conditions G sec value integrated RCF value can be measured and the operation with this value set is possible The timer can be set up to 990 minutes or seconds During hold operation the elapsed time of operation is displayed e Pre cooling function enables the rotor to reach low temperatures before the experiments 64cm width 78cm depth 86cm Height E Safety pursued 7780 conforms to International safety standard IEC 61010 2 020 The various alarm detector sensors secure operation When the alarm is detected the operation stops e Safety is increased by a rotor setup condition sensor that detects whether or not the rotor is properly set on the driver Shaft Patent pending Automatic rotor identification Patented Patent pending Rotor type is automatically identified E Sample temperature kept at 4 C At the ambient temperature of 25 C Please refer to the rotor E Design incorporates friendliness to the global environment and recycling A limited amount of plastic is used to reduce the load on the environment TEMP LIMIT lamp TEMP display TEMP knob SPEED knob SPEED display a i EA k display Pre cooling key DECEL key erm STEP key MEMORY Acceleration and
10. for distribution in the USA Canada Mexico and Australia as products shown are not for sale in these countries Copyright 2005 KUBOTA CORPORATION F4 Printed in Japan AS J
11. ion for detecting an occurrence of electrical abnormality in motor inverter lid interlock soeed sensor and temperature sensor Acceleration Deceleration e Three level selectors Rapid Slow and Super Slow Speed setting e From 300 to 22 000rpm 10rpm increments Speed indication Digital display From 0 to 22 500rpm 10rpm increments RCF setting e From 10 to 52 490xg 10xg increments RCF indication e Digital display From 0 to 54 900xg 10xg increments Integrator setting and indication e Digital display From 1 00 to 9 99x10 g sec Timer setting and indication e Digital display witn Hold and Memory Flashing from 1 sec to 100 sec in 1 sec increment from 100 sec to 990 sec in 10 sec increments from 1 min to 100 min in 1 min increment from 100 min to 990 min in 10 min increments Temperature setting and indication e Digital display 1 C increments Pre cooling Temperature setting range 20 C to 40 C Temperature indication 20 C to 43 C Refrigerant e R 404A Power requirements Single phase AC220V 10 230V 10 50 60Hz 30A Rated voltage and Rated current e 220 230V 50 60Hz 12A Power consumption and Heat output e 3500W 13MJ h Dimensions weight e 64 W x 78 D x 86 H cm 235kg Test standard e IEC 61010 2 020 Class 1 1 Those of projections are not included All specifications and external appearance subject to change without notice On Model 7780 only use KUBOTA made rotor adapter and tube rack Do not attempt use rotor
12. s adapters or tube racks made by other manufacturers The rotor mentioned in the catalogue is usable on other KUBOTA centrifuge models For details refer to the catalogues relevant to each model Follow instructions given in the relevant Instruction amp Service Manual for operating centrifuges For your safe use of the equipments be sure to read Parts may be adversely affected by heat humidity and specimens or the instruction manual carefully before you start its deteriorated by aging resulting in functional failures or may even lose their operation safety characteristic to cause accidents Safety Precautions The rotor or bucket has been found to be damaged or corroded To prevent occurrences of functional failures or accidents A burnt smell comes out of the equipment turn off the power switch pull out the power cable plug from You receive a minor electrification when you touch the the plug socket and be sure to contact your nearest Kubota equipment body by a naked hand Dealer or an office of Kubota Corporation when there is no Some other abnormality or failure has been found occurring Kubota Dealer in your neighbourhood Always discontinue use when phenomena listed DISCONTINUE at right appear USE KUBOTA CORPORATION http www centrifuge jp 29 9 Hongo 3 chome Bunkyo ku Tokyo 113 0033 Japan Tel 81 3 3815 1331 Fax 81 3 3814 2574 E mail f trade kubotacorp co jp Note This catalogue is not

Download Pdf Manuals

image

Related Search

Related Contents

NEC E325 Brochure  

Copyright © All rights reserved.
Failed to retrieve file