Home

KTI Networks KCD-303P-A1 User's Manual

image

Contents

1. Industrial 3 Port Fast Ethernet POF Media Converter Switches KCD 303P A series KCD 303P B series Installation Guide DOC 081022 1 18 C 2008 KTI Networks Inc All rights reserved No part of this documentation may be reproduced in any form or by any means or used to make any directive work such as translation or transformation without permission from KTI Networks Inc KTI Networks Inc reserves the right to revise this documentation and to make changes in content from time to time without obligation on the part of KTI Networks Inc to provide notification of such revision or change For more information contact United States KTI Networks Inc P O BOX 631008 Houston Texas 77263 1008 Phone 713 2663891 Fax 713 2663893 E mail kti ktinet com URL _ http www ktinet com International Fax 886 2 26983873 E mail kti ktinet com tw URL _ http www ktinet com tw 2 18 The information contained in this document is subject to change without prior notice Copyright C All Rights Reserved TRADEMARKS Ethernet is a registered trademark of Xerox Corp OptoLock is a registered trademark of Firecomms Ltd FCC NOTICE This device complies with Class B Part 15 the FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 this device must accept any interference received including the interference that may cause CE NOTICE Marki
2. To mount the device on a wall one wall mounting hole is provided on the bottom of the device Hang the device on the wall reliably The following figure illustrates example of a device bottom face 10 18 2 4 Panel Mounting The switches support panel mounting in industrial enclosure A panel mounting bracket is required for the mounting Install the bracket onto the device as shown in the figure below cee Panel Ore mounting bracket Screw M3x0 5 4mm After bracket installation the final dimension is shown below KCD 303P A 64 0 KCD 303P B 11 18 2 5 Din Rail Mounting To mount the device on a Din rail the optional Din rail mounting bracket is required Install the bracket onto the device Panel mounting bracket Screw M3x0 5 4mm After bracket installation the device 1s ready to be mounted on a din rail as shown below Din rail 12 18 2 6 Applying Power with Power Adapter The device provides a DC power jack for receiving DC power input from an external AC DC power adapter DC Jack DC power input Two types of AC DC power adapters are available for choice One is with typical operating temperature rating and the other is with extended operating temperature rating for critical applications as follows Typical Rating 0 40 C operating temperature Extended Rating 10 60 C operating temperature One power adapter is packed in each product package Consult
3. Configuration Network cables Distance IEEE 802 3 10Base T IEEE 802 3u 100Base TX Shielded RJ 45 jacks Auto MDI MDI X detection Auto negotiation 10Mbps 100Mbps Full Half duplex Cat 5 UTP up to 100 meters OptoLock connector RCLED 650nm 100Mbps Full duplex 1 5mm or 2 2mm POF model dependent 50 meters typical The different numeric aperture of POF might result in different transmit distance Distance of 100 meters tested with 0 3NA Mitsubishi Rayon Eska Mega POF 7 18 Far End Fault Support Switch Functions MAC Addresses Table Forwarding amp filtering Switching technology Maximum packet length Flow control Broadcast Storm DC IN Power Input Interfaces Operating Voltages Power Consumption Mechanical Dimension base Housing Mounting Support Environmental Operating Temperature Storage Temperature Relative Humidity Electrical Approvals FCC CE Safety Enabled 1K entries Non blocking full wire speed Store and forward 1552 bytes max IEEE 802 3x pause frame base for full duplex operation Back pressure for half duplex operation Protection design DC IN Jack D 6 3mm D 2 0mm 4 75 12 6VDC 2W max 64 x 59 x 21 mm Enclosed metal with no fan Panel mounting Wall mounting Desktop mounting Main body 0 C 70 C 20 C 85 C 10 90 Part 15 rule Class B EMC CISPR22 Class B IEC60950 1 EN60950 8 18 2 Installation 2 1 Unpacking The pro
4. your purchasing agency for the right part number which matching the operating rating you require Note Before you begin the installation check the AC voltage of your area The AC DC power adapter should have the AC voltage matching the commercial power voltage in your area 13 18 2 7 Applying Power via USB The USB port on the common computers provides an output of 5V 300mA equally 5V 2 5Watt for the connected USB devices With an USB DC power cable the USB power is applicable to the devices and serves as a handy power and eliminates the need for extra power adapters and occupation of limited AC power sockets One optional USB DC power cable is available for purchasing to supply power for the switch via USB connection To make the connection the steps are 1 Connect the USB A plug end of the cable to an USB High power port for power source 2 Connect power plug end of the cable to the device Notes 1 The cable must be connected to USB High power port for power source 2 The power source maybe shared by other USB powered devices Make sure it can deliver 500mA for the cable to the KTI network device 3 When connected to an USB hub the result is unpredictable since other devices connected to the hub are sharing the limited DC power When power is insufficient the network device would operate incorrectly 14 18 3 Making LAN Connections 3 1 Making Copper Port RJ 45 Connections The copp
5. catiON ccccooncccccconcnncocononocononononos 18 4 18 1 Introduction The industrial rated KCD 303P series supports three switched connections including copper and fiber for networks over POF Plastic Optical Fiber The copper ports support 10 100Mbps auto negotiation and auto MDI MDIX for Cat 5 plug and play The fiber ports support plug less connections of high bandwidth 100Mbps data rate over POF cables POF technology offers a complementary solution to UTP copper wire for industrial office and home networks because it is low cost weight little thin easy and safe to install and electronic noise immunity Depending on the types of the network ports and the supported POF cables several different models are defined as follows Copper Port RJ 45 Fiber Port POF POF Support KCD 303P A2 The switch also provide the following advantages Plug and Play No configuration is required in using the switches With the featured auto negotiation function the switches can detect and configure the connection speed and duplex automatically for the copper ports The switches also provide auto MDI MDI X function which can detect the connected cable and switch the transmission wire pair and receiving pair automatically This auto crossover function can simplify the type of network cables used POF Connectivity The switches support plug less POF connection Both model series offer an ideal solution for POF deployment i
6. duct package contains e The switch unit e One AC DC power adapter e One product CD ROM 2 2 Safety Cautions To reduce the risk of bodily injury electrical shock fire and damage to the product observe the following precautions Do not service any product except as explained in your system documentation Opening or removing covers may expose you to electrical shock Only a trained service technician should service components inside these compartments If any of the following conditions occur unplug the product from the electrical outlet and replace the part or contact your trained service provider The power cable extension cable or plug is damaged An object has fallen into the product The product has been exposed to water The product has been dropped or damaged The product does not operate correctly when you follow the operating instructions Do not push any objects into the openings of your system Doing so can cause fire or electric shock by shorting out interior components Operate the product only from the type of external power source indicated on the electrical ratings label If you are not sure of the type of power source required consult your service provider or local power company 9 18 2 3 Mounting on a Wall The device can be mounted on a desktop or shelf Make sure that there is proper heat dissipation from and adequate ventilation around the device Do not place heavy objects on the device
7. er ports support the following connection types and distances Network Cables IOBASE T 2 pair UTP Cat 3 4 5 EIA TIA 568B 100 ohm 1OOBASE TX 2 pair 4 pair UTP Cat 5 E A TIA 568B 100 ohm Link distance Up to 100 meters Auto MDI MDI X Function This function allows the port to auto detect the twisted pair signals and adapts itself to form a valid MDI to MDI X connection with the remote connected device automatically No matter a straight through cable or crossover cable connected the ports can sense the receiving pair automatically and configure self to match the rule for MDI to MDI X connection It simplifies the cable installation Auto negotiation Function The ports are featured with auto negotiation function and full capability to support connection to any Ethernet devices The port performs a negotiation process for the speed and duplex configuration with the connected device automatically when each time a link is being established If the connected device is also auto negotiation capable both devices will come out the best configuration after negotiation process If the connected device is incapable in auto negotiation the switch will sense the speed and use half duplex for the connection 15 18 3 2 Making POF Connections POF Cable Depending on the model specified two different sizes of POF cables are supported One is 1 5mm and the other is 2 2mm in diameter The following figure illustrates 2 2mm POF and Cat 5 as co
8. etwork Four devices are cascaded by POF cables Fiber Cascading 4 2 Application For Home Network The following figure illustrates an application example in home network 4 3 Copper to POF Media Converter Application The following figure illustrates an application of copper Cat 5 to POF media conversion Cat 5 POF 18 18
9. mparison 2 2mm 4 6mm 5 5mm Typ 2 2mm POF Cat 5 Easy POF Installation The design of the device enables the POF to be cut and terminated to the exact required length on site allowing even the most novice user to quickly and easily terminate the bare POF fiber To terminate the POF cable into OptoLock connector the end of the cable is cut cleanly and the two strands are separated One strand is inserted into each of two holes in the termination housing which is then pressed closed to hold the POF in place press to lock Note When cutting the cable use sharp knife and make a quick cut POF Connector Identify TX and RX holes on OptoLock connector before making cable connection POF Connector OptoLock 16 18 The following figure illustrates a connection example between two POF ports located on two devices Fiber cable RA TA Fiber cahle TA RA Make sure the Rx to Tx connection rule is followed on the both ends of the cable 3 3 LED Indication LED Indicators LED Function State Interpretation POWER Power status ON The power is supplied to the device OFF The power is not supplied to the device Px Link Act Port Px link status ON Port link is established No traffic BLINK Port link is up and there is traffic OFF Port link 1s down 17 18 4 Applications 4 1 Application in Industrial Networks The following figure illustrates an application example in an industrial n
10. n home and industrial networks For the application need 1 5mm POF and 2 2mm POF are supported in different models Industrial Features For industrial environment the main devices are designed with the following enhanced features exceeding that of commercial Ethernet switches e High and wide operating temperature 5 18 e Screw panel mounting support for industrial enclosure oeooeeoeoeeoe _ Optional AC DC power adapters with extended operating temperature range Industrial rated Emission and Immunity performance 1 Features Supports 3 switching base network segments 2 x Copper 1 x POF and 1 x Copper 2 x POF Auto MDI MDI X crossover function on the UTP copper port Supports EEE 802 3x flow control for full duplex operation Supports Back pressure flow control for half duplex operation Wide operating temperature range for temperature critical environment Supports desktop mounting panel mounting and optional Din rail mounting Industrial rated Emission and Immunity performance 1 2 Product Panels The following figure illustrates the faces of the switches KCD 303P A DC IN Power Input LED Indicators Copper ports RJ 45 POF port 6 18 KCD 303P B DC IN Power Input LED Indicators Copper port RJ 45 POF ports 1 3 Specifications Copper Ports Compliance Connectors Pin assignments Configuration Transmission rate Duplex support Network cable POF Ports Connectors Optical
11. ng by the symbol indicates compliance of this equipment to the EMC directive of the European Community Such marking is indicative that this equipment meets or exceeds the following technical standards EMC Class B EN 5008 1 1 1992 EN55022 1994 A1 1995 A2 1997 Class B EN61000 3 2 2000 EN61000 3 3 1995 A 1 2001 EN 55024 1998 A1 2001 IEC 61000 4 2 1995 IEC 61000 4 3 1995 IEC 61000 4 4 1995 IEC 61000 4 5 1995 IEC 61000 4 6 1996 IEC 61000 4 8 1993 IEC 61000 4 11 1994 3 18 Table of Contents Wes MPATROGUICHON risser oxsansssesceuseeuaskaescucsestesoxsauss ana Ee aaaea 5 Wr Foa aa mes ena ep eat aa etna unt etamaan tenn ea teenie tua ieee ceunmn ete nase 6 152 Product Panc Saa 6 A sa a mee eneGts 7 AAPP 9 2 UNPACKING O 9 Bee SOIC LY CAUTO S eaa EE O E EET EE A 9 23 IMOUAUNO on a Walk isa a sad 10 24 Panek MOUA TO serene e 11 220 DIN Fall WIOUIMINNG dsd 12 2 6 Applying Power with Power Adapter cccccsscccsseecseeeeceeeeseeeeeseeeseeeeseeeensaees 13 27 SPOONING ROW CL Wa SB ea te cate eed el 14 os Making LAN CONNECTIONS venia 15 3 1 Making Copper Port RJ 45 Connections cccooooncccccconconccnnnccnnnnonennnonnncnnconancnnnos 15 3 2 Making POR ConnecighS cata lao ieee 16 39 ED A RAEE AEAEE 17 A PADDING AION ad 18 4 1 Application in Industrial Networks cccooocccconnccocnnconcnonococonanonnnconnncnonncnnnonos 18 4 2 Application For Home Network Cossa 18 4 3 Copper to POF Media Converter Appli