Home
Kramer Electronics fc-42 User's Manual
Contents
1. Global parameters are changed the front panel as a result of execution of any other command NOTE 2 If it is necessary merely to save adjusted parameters in initial setup number no setup number change then the value of byte3 must be equal to the value of byte2 initial setup number NOTE 3 The reply to the Identify Machine command shows the machine name 1st byte Ox7d 2nd byte 0x80 0x00 0 dec 8rd byte 0x80 0x29 41 dec for the unit FC 42 4th byte 0x98 NOTE 4 The reply to the Identity Firmware command shows the firmware version as 1st byte Ox7d 2nd byte 0x80 the version number prior to decimal point 8rd byte 0x80 the version number following the decimal point 4th byte 0x98 For example for version 3 5 the reply would be 0x7d 0x83 0x85 0x98 FC 42 Communication Protocol LIMITED WARRANTY The warranty obligations of Kramer Electronics for this product are limited to the terms set forth below Whatis Covered This limited warranty covers defects in materials and workmanship in this product What is Not Covered This limited warranty does not cover any damage deterioration or malfunction resulting from any alteration modification improper or unreasonable use or maintenance misuse abuse accident neglect exposure to excess moisture fire improper packing and shipping such claims must be presented to the carrier lightning power surges or other acts of natur
2. 6 Using the FC 42 Component To HD SDI Converter This section describes how to Lock unlock the front panel button see Section 6 1 e Operate the FC 42 see Section 6 2 6 1 Locking the Front Panel To prevent changing the settings accidentally or tampering with the unit via the front panel buttons lock your converter Unlocking releases the protection mechanism Even though the front panel is locked you can still operate via RS 232 To lock the converter Press the LOCK button for more than three seconds until the LOCK button is illuminated The front panel is locked Pressing a button has no effect other than causing the LOCK button to flash Warning that you need to unlock to regain control via the front panel To unlock the converter e Press the illuminated LOCK button for more than three seconds until the LOCK button is no longer illuminated The front panel unlocks 6 2 Operating the FC 42 HD SDI to Component Converter The converter can save and load up to 16 setups via the converter menu To use the menu press the e MENU button to start or exit the menu e ENTER button to enter a submenu load a setup accept changes and reset to the default settings e f and amp buttons to scroll through the menu and sub menus AD 2 42 Using the FC 42 Component To HD SDI Converter e h and to increase or decrease numerical values or select from several definitions of a setup The converter automatically
3. Obtain a Remedy under this Limited Warranty To obtain a remedy under this limited warranty you must contact either the authorized Kramer Electronics reseller from whom you purchased this product or the Kramer Electronics office nearest you For a list of authorized Kramer Electronics resellers and or Kramer Electronics authorized service providers please visit our web site at www kramerelectronics com or contact the Kramer Electronics office nearest you In order to pursue any remedy under this limited warranty you must possess an original dated receipt as proof of purchase from an authorized Kramer Electronics reseller If this product is returned under this limited warranty a return authorization number obtained from Kramer Electronics will be required You may also be directed to an authorized reseller or a person authorized by Kramer Electronics to repair the product Ifitis decided that this product should be returned directly to Kramer Electronics this product should be properly packed preferably in theoriginal carton for shipping Cartons not bearing a return authorization number will be refused Limitation on Liability THE MAXIMUM LIABILITY OF KRAMER ELECTRONICS UNDER THIS LIMITED WARRANTY SHALL NOT EXCEED THE ACTUAL PURCHASE PRICE PAID FOR THE PRODUCT TO THE MAXIMUM EXTENT PERMITTED BY LAW KRAMER ELECTRONICS IS NOT RESPONSIBLE FOR DIRECT SPECIAL INCIDENTAL OR CONSEQUENTIAL DAMAGES RESULTING FROM ANY BREACH OF WARRANTY OR CONDITION
4. Parameter Number Parameter Number gen Parameter Number 720p 59 Input Standard B 1080sf 30 D 1080sf 25 E 1080sf 24 F 1080sf 23 Local Parameter Data gt 5 A E EE EA N co o 9 S Lt S wv ms msiol2iso sje D wl A ajojo Mode Input Standard QoS u Forced 0 Bi Level Tri Level Test Signal Badc o _ Yoan fo eme 1 stop Gan Ton 865 s8 1 step Coo feres _ 1 stop BY 06 665 8 1 step 0D 665 69 _ 1 stop Sharpness 0 0 150 10 step SYNC Type Communication Protocol The following table defines the global parameter data Global Parameter HE Description 0 Off Default Panel Lock o earan Machine Address b Setup Number 0 Black Screen Default Free Run Mode ee Blue 1 BlueScreen ______ Global Parameter Data Se 2 aren 1080 60 4 IXRE 1080 50 6 TN 7 00 naar Hed one 8 ison o o AUTO Mode Only 9 T A B SS BD ME 1080s1 29 D LARES E F Not Identified 11 11 Not Identified _______ Identified Presence of Input Signal Signal is Present Read Only No Input 1 Signal NOTE 1 These commands are sent by the unit also when Local
5. Warning Disconnect the power and unplug the unit from the wall before installing Recycling Kramer Products The Waste Electrical and Electronic Equipment WEEE Directive 2002 96 EC aims to reduce the amount of WEEE sent for disposal to landfill or incineration by requiring it to be collected and recycled To comply with the WEEE Directive Kramer Electronics has made arrangements with the European Advanced Recycling Network EARN and will cover any costs of treatment recycling and recovery of waste Kramer Electronics branded equipment on arrival at the EARN facility For details of Kramer s recycling arrangements in your particular country go to our recycling pages at http www kramerelectronics com support recycling 3 Overview The Kramer FC 42 is a high performance converter for high definition HD component video Y PB PR It converts the component video input Y PB PR to HD SDI on two BNC output connectors The signal is also converted to an RGB HV signal on a 15 pin HD computer graphics video connector In addition the FC 42 features HDTV compatibility Multi standard operation SDI SMPTE 259M and SMPTE 344M amp HD SDI SMPTE 292M HD resolutions of 720p and 1080 up to 60 2 4 1080p up to 30Hz Bi level and tri level sync input No resolution conversion ProcAmp control with memory for 16 setups A test pattern generator with eight patterns Control using the front panel with LCD display and RS 23
6. converts the input signal according to the setup loaded from the menu The setup is defined via the menu To operate the converter press the MENU button to enter the menu and load the desired setup from 1 to 16 The following table defines the menu items Menu Item Submenu Select Notes 1 LOAD SETUP From 1 to 16 Refers to the setup 2 SAVE SETTING AS From 1 to 16 number from 1 to 16 SET STANDARD AUTO FORCED SET STANDARD 720p 59 720p 50 1080i 60 10801 59 10801 50 1080p 30 1080p 29 1080p 25 1080p 24 1080p 23 1080sf 30 1080sf 29 1080sf 25 1080sf 24 1080sf 23 SET SYNC TYPE From 6ir1069 From 0 155 O 5 C p d 7 GRID SET Free run mode BLACK SCREEN BLUE SCREEN SET Address of First Second machine SET IMAGE TUNING 1 FACTORY RESET Sets all the image enter submenu tuning parameters to zero 2 Using the FC 42 Component To HD S 7 Technical Specifications INPUT 1 RGB HV on a 15 pin HD connector OUTPUT LEVEL RESOLUTION Up to 1080p S N RATIO 49dB unweighted CONTROLS Front panel buttons MENU ENTER menu arrows LOCK rear panel RS 232 POWER CONSUMPTION STORAGE TEMPERATURE 40 to 70 C 40 to 158 F DIMENSIONS WEIGHT ACCESSORIES Power cord null modem adapter Specifications are subject
7. rack avoid hazards by taking care that 1 It is located within the recommended environmental conditions as the operating ambient temperature of a closed or multi unit rack assembly may exceed the room ambient temperature 2 Once rack mounted enough air will still flow around the machine 3 The machine is placed straight in the correct horizontal position 4 You do not overload the circuit s When connecting the machine to the supply circuit overloading the circuits might have a detrimental effect on overcurrent protection and supply wiring Refer to the appropriate nameplate ratings for information For example for fuse replacement see the value printed on the product label 5 The machine is earthed grounded in a reliable way and is connected only to an electricity socket with grounding Pay particular attention to situations where electricity is supplied indirectly when the power cord is not plugged directly into the socket in the wall for example when using an extension cable or a power strip and that you use only the power cord that is supplied with the machine FC 42 Installing in a Rack To rack mount a machine 1 Attach both ear brackets to the machine To do so remove the screws from each side of the machine 3 on each side and replace those screws through the ear brackets 2 Place the ears of the machine against the rack rails and insert the proper screws not provided throug
8. to repair or facilitate the repair of any defective parts within a reasonable period of time free of any charge for the necessary parts and labor to complete the repair and restore this product to its proper operating condition Kramer Electronics will also pay the shipping costs necessary to return this product once the repair is complete 2 Replace this product with a direct replacement or with a similar product deemed by Kramer Electronics to perform substantially the same function as the original product 3 Issue a refund of the original purchase price less depreciation to be determined based on the age of the product at the time remedy is sought under this limited warranty What Kramer Electronics will not do Under This Limited Warranty If this product is returned to Kramer Electronics or the authorized dealer from which it was purchased or any other party authorized to repair Kramer Electronics products this product must be insured during shipment with the insurance and shipping charges prepaid by you If this product is returned uninsured you assume all risks of loss or damage during shipment Kramer Electronics will not be responsible for any costs related to the removal or re installation of this product from or into any installation Kramer Electronics will not be responsible for any costs related to any setting up this product any adjustment of user controls or any programming required for a specific installation of this product How to
9. 2 A worldwide power supply 100 240V AC Standard 19 rack mount size of 1U with included rack ears 3 1 Defining the FC 42 Component to HD SDI Converter This section defines the FC 42 4 2 9 SETUP MENU Component HD SDI Converter Figure 1 FC 42 Component to HD SDI Converter Front Panel Feature Function Illuminated switch for turning the unit ON or OFF Press to open the menu see Section 6 2 4 ENTER Button Press to load and save a set up and to accept changes 5 __ Button Press to decrease numerical values or select from several definitions 5 __ Button ____________ Presstomoveupthemenulistvalues __ _____ __ Button Presstomove down the menu list ______ 9 LOCK Button Press and hold for about seconds to lock unlock the tront panel buttons Zt 24 o Feature Function Y BNC Connector INPUTS PB BNC Connector Connects to a component video source OUTPUTS Power Connector with Fuse AC connector enabling power supply to the unit 4 Installing in Rack This section provides instructions for rack mounting the unit Before installing in a rack be sure that the environment is within the recommended range 0 to 40 C 32 to 104 F 40 to 70 C 40 to 158 F 10 to 90 RHL non condensing OPERATING TEMPERATURE STORAGE TEMPERATURE HUMIDITY CAUTION When installing on a 19
10. Component Converter 7 Technical Specifications 8 Communication Protocol Figures Figure 1 FC 42 Component to HD SDI Converter Front Panel Figure 2 FC 42 Component to HD SDI Converter Rear Panel Figure 3 Connecting the FC 42 Component to HD SDI Converter Figure 4 Crossed Cable RS 232 Connection Figure 5 Straight Cable RS 232 Connection with a Null Modem Adapter N ARA OONN ak ak zd c Introduction Welcome to Kramer Electronics Since 1981 Kramer Electronics has been providing a world of unique creative and affordable solutions to the vast range of problems that confront video audio presentation and broadcasting professionals on a daily basis In recent years we have redesigned and upgraded most of our line making the best even better Our 1 000 plus different models now appear in 11 groups that are clearly defined by function GROUP 1 Distribution Amplifiers GROUP 2 Switchers and Routers GROUP 3 Control Systems GROUP 4 Format Standards Converters GROUP 5 Range Extenders and Repeaters GROUP 6 Specialty AV Products GROUP 7 Scan Converters and Scalers GROUP 8 Cables and Connectors GROUP 9 Room Connectivity GROUP 10 Accessories and Rack Adapters and GROUP 11 Sierra Products Congratulations on purchasing your Kramer FC 42 Component to HD SDI Converter which is ideal for the following typical applications e Broadcast and production video studi
11. Component to HD SDI Converter FC 42 Connecting the 42 5 1 Connecting to the FC 42 via RS 232 You can connect to the unit via a crossed RS 232 connection using for example a PC A crossed cable or null modem is required as shown in method A and B respectively If a shielded cable is used connect the shield to pin 5 Method A Figure 4 Connect the RS 232 9 pin D sub port on the unit via a crossed cable only pin 2 to pin 3 pin 3 to pin 2 and pin 5 to pin 5 need be connected to the RS 232 9 pin D sub port on the PC Note There is no need to connect any other pins Figure 4 Crossed Cable RS 232 Connection Hardware flow control is not required for this unit In the rare case where a controller requires hardware flow control short pin 1 to 7 and 8 and pin 4 to 6 on the controller side Method B Figure 5 Connect the RS 232 9 pin D sub port on the unit a straight flat cable to the null modem adapter and connect the null modem adapter to the RS 232 9 pin D sub port on the PC The straight cable usually contains all nine wires for a full connection of the D sub connector Because the null modem adapter which already includes the flow control jumpering described in Method A above only requires pins 2 3 and 5 to be connected you are free to decide whether to connect only these 3 pins or all 9 pins Figure 5 Straight Cable RS 232 Connection with a Null Modem Adapter FC 42 Connecting the FC 42
12. KRAMER ELECTRONICS LTD USER MANUAL MODEL FCc 42 Component to HD SDI Converter P N 2900 000384 Rev 3 This guide helps you install and use your product the first For more detailed information go to http www kramerelectronics com support product_downloads asp to download the latest manual or scan the QR code on the left Step 1 Check what s in the box FC 42 Component to HD SDI Converter 1 Set of rack ears 1 Power cord 4 Rubber feet 1 Quick Start sheet Step 2 Install the FC 42 Mount the FC 42 in a rack using the included rack ears or attach the rubber feet and place on a table Step 3 Connect the inputs and outputs Non Linear HD SDI Editor Display Computer Controller Projector Step 4 Connect the power Connect the power cord to the FC 42 and plug it into the mains electricity Step 5 Operate the FC 42 Operate the machine through the front panel buttons and or the RS 232 controller MENU ENTER 4 LIS LI EZ L LI sq LOCK Contents 1 Introduction 2 Getting Started 2 1 Achieving the Best Performance 2 2 Safety Instructions 2 3 Recycling Kramer Products 3 Overview 3 1 Defining the FC 42 Component to HD SDI Converter 4 Installing in a Rack 5 Connecting the FC 42 5 1 Connecting to the FC 42 via RS 232 6 Using the FC 42 Component To HD SDI Converter 6 1 Locking the Front Panel 6 2 Operating the FC 42 HD SDI to
13. OR UNDER ANY OTHER LEGAL THEORY Some countries districts or states do not allow the exclusion or limitation of relief special incidental consequential or indirect damages or the limitation of liability to specified amounts so the above limitations or exclusions may not apply to you Exclusive Remedy TO THE MAXIMUM EXTENT PERMITTED BY LAW THIS LIMITED WARRANTY AND THE REMEDIES SET FORTH ABOVE ARE EXCLUSIVE AND IN LIEU OF ALL OTHER WARRANTIES REMEDIES AND CONDITIONS WHETHER ORAL OR WRITTEN EXPRESS OR IMPLIED TO THE MAXIMUM EXTENT PERMITTED BY LAW KRAMER ELECTRONICS SPECIFICALLY DISCLAIMS ANY AND ALL IMPLIED WARRANTIES INCLUDING WITHOUT LIMITATION WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE IF KRAMER ELECTRONICS CANNOT LAWFULLY DISCLAIM OR EXCLUDE IMPLIED WARRANTIES UNDER APPLICABLE LAW THEN ALL IMPLIED WARRANTIES COVERING THIS PRODUCT INCLUDING WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE SHALL APPLY TO THIS PRODUCT AS PROVIDED UNDER APPICABLE LAW IF ANY PRODUCT TO WHICH THIS LIMITED WARRANTY APPLIES IS A CONSUMER PRODUCT UNDER THE MAGNUSON MOSS WARRANTY ACT 15 U S C A 82301 ET SEQ OR OTHER APPICABLE LAW THE FOREGOING DISCLAIMER OF IMPLIED WARRANTIES SHALL NOT APPLY TO YOU AND ALL IMPLIED WARRANTIES ON THIS PRODUCT INCLUDING WARRANTIES OF MERCHANTABILITY AND FITNESS FOR THE PARTICULAR PURPOSE SHALL APPLY AS PROVIDED UNDER APPLICABLE LAW Other Conditions This limited warranty
14. e This limited warranty does not cover any damage deterioration or malfunction resulting from the installation or removal of this product from any installation any unauthorized tampering with this product any repairs attempted by anyone unauthorized by Kramer Electronics to make such repairs or any other cause which does not relate directly to a defect in materials and or workmanship of this product This limited warranty does not cover cartons equipment enclosures cables or accessories used in conjunction with this product Without limiting any other exclusion herein Kramer Electronics does not warrant that the product covered hereby including without limitation the technology and or integrated circuit s included in the product will not become obsolete or that such items are or will remain compatible with any other product or technology with which the product may be used How Long Does this Coverage Last Seven years as of this printing please check our Web site for the most current and accurate warranty information Whois Covered Only the original purchaser of this product is covered under this limited warranty This limited warranty is not transferable to subsequent purchasers or owners of this product What Kramer Electronics will do Kramer Electronics will at its sole option provide one of the following three remedies to whatever extent it shall deem necessary to satisfy a proper claim under this limited warranty 1 Elect
15. gives you specific legal rights and you may have other rights which vary from country to country or state to state This limited warranty is void if i the label bearing the serial number of this product has been removed or defaced ii the product is not distributed by Kramer Electronics or iii this product is not purchased from an authorized Kramer Electronics reseller If you are unsure whether a reseller is an authorized Kramer Electronics reseller please visit our Web site at www kramerelectronics com or contact a Kramer Electronics office from the list at the end of this document Your rights under this limited warranty are not diminished if you do not complete and return the product registration form or complete and submit the online product registration form Kramer Electronics thanks you for purchasing a Kramer Electronics product We hope it will give you years of satisfaction For the latest information on our products and list of Kramer distributors visit our Web site where updates to this user manual may be found We welcome your questions comments and feedback Web site www kramerelectronics com KRAMER E mail info kramerel com SAFETY WARNING Disconnect the unit from the power e Supply before opening and servicing 4
16. h each of the four holes in the rack ears Note In some models the front panel may feature built in rack ears Detachable rack ears can be removed for desktop use Always mount the machine in the rack before you attach any cables or connect the machine to the power f you are using a Kramer rack adapter kit for a machine that is not 19 see the Rack Adapters user manual for installation instructions available from our Web site 5 Connecting the FC 42 Always switch off the power to each device before connecting it to your FC 42 After connecting your FC 42 connect its power and then switch on the power to each device To connect the FC 42 as illustrated in the example in Figure 3 do the following 1 Connect a component video source for example an HDTV Satellite receiver source to the Y PB PR INPUT BNC connectors 2 Connect the OUTPUTS Connect the SDI BNC connector to an HD SDI acceptor for example a non linear editor Connect the SDI BNC connector to an HD SDI acceptor for example an HD SDI display Connect the RGB HV 15 HD computer graphics video connector to an RGBHV acceptor for example a projector 3 Connect a PC or other controller if required see Section 5 1 4 Connect the power cord not shown in Figure 3 T FC 42 Connecting the FC 42 HDTV Satellite Receiver Source Non Linear Editor HD SDI Display Projector Figure 3 Connecting the FC 42
17. os e Postproduction and duplication studios e Non linear editing 2 1 Getting Started We recommend that you Unpack the equipment carefully and save the original box and packaging materials for possible future shipment Review the contents of this user manual Go to http www kramerelectronics com to check for up to date user manuals application programs and to check if firmware upgrades are available where appropriate Achieving the Best Performance To achieve the best performance Use only good quality connection cables we recommend Kramer high performance high resolution cables to avoid interference deterioration in signal quality due to poor matching and elevated noise levels often associated with low quality cables Do not secure the cables in tight bundles or roll the slack into tight coils Avoid interference from neighboring electrical appliances that may adversely influence signal quality Position your Kramer FC 42 away from moisture excessive sunlight and dust This equipment is to be used only inside a building It may only be connected to other equipment that is installed inside a building 2 2 2 3 12 Getting Started Safety Instructions Caution There are no operator serviceable parts inside the unit Warning Use only the power cord that is supplied with the unit Warning not open the unit High voltages can cause electrical shock Servicing by qualified personnel only
18. to change without notice at http Awww kramerelectronics com 12 Technical Specifications Communication Protocol The FC 42 is compatible with the protocol ver 1 2 described below For RS 232 a null modem connection between the FC 42 and controller is used The default data rate is 9600 baud with no parity 8 data bits and 1 stop bit All the values shown are hexadecimal Instruction Byte 1 Byte 2 Byte 3 Byte 4 Notes RESET 98 Machine Addr REPLY TO 40 98 Machine RESET Addr READ LOCAL 20 80 Parameter B8 Machine PARAMETER Number Addr REPLY TO READ 80 Parameter 80 Parameter B8 Machine LOCAL Number Data Addr PARAMETER WRITE LOCAL 21 80 Parameter 80 Parameter B8 Machine PARAMETER Number Data Addr REPLY TO 80 Parameter 80 Parameter B8 Machine 1 WRITE LOCAL Number Data Addr PARAMETER READ GLOBAL 20 80 Parameter 98 Machine PARAMETER Number Addr REPLY TO READ 80 Parameter 80 Parameter 98 Machine GLOBAL Number Data Addr PARAMETER WRITE GLOBAL 21 80 Parameter 80 Parameter 98 Machine PARAMETER Number Data Addr REPLY TO 61 80 Parameter 80 Parameter 98 Machine 1 WRITE GLOBAL Number Data Addr PARAMETER SAVE 23 80 Initial 80 Destination 98 Machine 2 Setup Setup Number Addr Number IDENTIFY 3D 81 98 Machine 3 MACHINE Addr IDENTIFY 3D 83 98 Machine 4 FIRMWARE Addr VERS FC 42 Communication Protocol The following table defines the local parameter data gen
Download Pdf Manuals
Related Search
Related Contents
T Type (Concrete) PV Mounting Structure Installation Greenmaster FX40HR User's Manual USER`S MANUAL D-3K ノ iiyama MD 052B1000 flat panel wall mount Targus Student Backpack Cowon Systems iAUDIO G3 User's Manual User Manual - stahl Copyright © All rights reserved.
Failed to retrieve file