KitchenAid W10267109C User's Manual
Contents
1. Replace the metal grease filters See Range Hood Care section Push the range hood screen back in 13 HOOD USE The range hood is designed to remove smoke cooking vapors and odors from the cooktop area For best results start the range hood before cooking and allow it to operate several minutes after the cooking is complete to clear all smoke and odors from the kitchen Fan Control ND Operating the Fan 1 Slide the range hood screen forward NOTE When the screen is opened the fan will operate at the fan switch setting that it was at when the screen was closed The fan will shut off when the screen is about 2 5 1 cm from the closed position 2 To turn fan On move the fan switch from 0 Off to the desired fan speed 1 Low 2 Medium 3 High NOTE The speed may be increased decreased or turned off at anytime during the range hood operation 14 3 To turn the fan Off move the fan switch to 0 Off or close the Screen NOTE The fan will shut off when the screen is about 2 b 1 cm from the closed position When the screen is opened the fan will operate at the last setting Light Control Operating the Light Open the range hood screen 2 Toturn light On move the switch from 0 Off to 1 On NOTE If the light switch is left in the 1 On position the light will be on each time the screen is opened It can also be
2. 30 76 2 cm model 3518 91 1 cm 36 91 4 cm model Cabinet Dimensions m Vent system must terminate to the outside except for non pubem vented recirculating installations m Do not terminate the vent system in an attic or other enclosed area 30 76 2 cm or _ 36 91 4 cm min cabinet opening width Do not use a 4 10 2 cm laundry type wall caps Use a metal vent only A rigid metal vent is recommended Plastic or metal foil vent is not recommended m The length of vent system and number of elbows should be kept to a minimum to provide efficient performance 24 61 cm min 30 76 2 cm suggested max bottom of cabinet to cooking surface a Aust 15 38 1 cm E For the most efficient and quiet operation 13 83cm m Use no more than three 90 elbows cabinet depth m Make sure there is a minimum of 24 61 0 cm of straight min clearance vent between the elbows if more than 1 elbow is used Do not install 2 elbows together upper cabinet Y to countertop u T ae gt ps ae m The vent system must have a damper If the roof or wall cap a has a damper do not use the damper supplied with the range hood m Use clamps to seal all joints in the vent system 36 91 4 cm m Use caulking to seal exterior wall or roof opening around the base cabinet cap height m The size of the vent
3. rieure Vis de bride de montage B Tournevis lame plate REMARQUE Pour certaines configurations d installation sans d charge l int rieur recyclage il peut tre plus facile de fixer le circuit d vacuation la hotte avant de soulever la hotte jusqu son emplacement final Serrer le point de connexion avec des brides 28 AVERTISSEMENT Risque du poids excessif Utiliser deux ou plus de personnes pour d placer et installer la hotte de la cuisini re Le non respect de cette instruction peut causer une blessure au dos ou d autre blessure l aide d au moins deux personnes soulever la hotte et la placer son emplacement final Le c blage et le bo tier de connexion doivent se trouver au dessus de la hotte Les brides de montage doivent chevaucher le fond du placard ou les tringles d appui en bois Centrer la hotte E A Bride de montage B Tringle d appui en bois facultative Fond du placard D Tringle d appui en bois facultative pour placard encastr E Hotte coulissante 5 V rifier que le panneau avant est parall le la facade du placard lorsque le filtre est enfonc Faire coulisser le filtre vers avant Serrer les vis de la bride de montage pour fixer la hotte au placard A Vis de bride de montage B Tournevis lame plate Aligner le panneau avant de la hotte avec le placard Faire glisser le filtre vers l avant Identifier
4. 2 cm Wall 90 elbow 6 ft 1 8 m gt X 3 ft 0 93 m Vent Piece 6 15 2 cm 45 elbow 2 5 ft 0 8 m 9 90 elbow 5 0 ft 1 5m 6 Maximum Length 35 ft 10 7 m 1 90 elbow 5 1 5 1 wall cap 0ft 0m 9 ft 2 8 m straight 9ft 2 8 m System length 14 ft 4 3 m Non Vented recirculating Installations Through the Soffit Cabinet If it is not possible to vent cooking fumes and vapors to the outside the range hood can be used in the non vented recirculating version using charcoal filters Recirculation Kit Part Number 4396565 is available from the dealer or an authorized parts distributor Damper installation is not required A A Doe B 7 d B aa I 1 C 4 D F E E A Ceiling D 6 15 2 cm vent B Vent cover E Range hood C Soffit F Cabinet Observe all governing codes and ordinances Ensure that the electrical installation is adequate and in conformance with National Electrical Code ANSI NFPA 70 latest edition or CSA Standards C22 1 94 Canadian Electrical Code Part 1 and C22 2 No 0 M91 latest edition and all local codes and ordinances lf codes permit and a separate ground wire is used it is recommended that a qualified electrician determine that the ground path is adequate copy of the above c
5. 7 Connecter ensemble les conducteurs blancs A l aide de connecteurs de fils homologation UL A Conducteurs blancs D Conducteurs noirs B Vis verte de liaison la terre E Connecteurs de fils C Conducteur de liaison la terre Risque d incendie Relier le ventilateur la terre Utiliser du fil en cuivre Brancher le fil reli la terre la vis verte reli e la terre dans la boite de la borne Le non respect de ces instructions peut causer un d c s un incendie ou un choc lectrique 8 Connecter le conducteur de liaison la terre vert ou nu du c ble d alimentation du domicile la vis verte de liaison la terre situ e dans le boitier de connexion de la hotte Serrer la vis verte de liaison la terre Utiliser un calfeutrant pour assurer l tanch it au point de travers e du c blage 9 Serrer la vis du serre c ble 10 Installer le couvercle du boitier de connexion REMARQUE Ne pas mettre le syst me sous tension avant d avoir compl tement termin l installation 6 Installations avec d charge l ext rieur R installer les filtres m talliques Voir la section Entretien de la hotte Connecter le circuit d vacuation sur l ouverture de d charge de la hotte Serrer le point de connexion avec des brides Reconnecter la source de courant lectrique Contr ler le fonctionnement du ventilateur de la hotte et de la lampe Remettre l l ment coulissant de
6. Park Quincy MA 02269 CSA International 8501 East Pleasant Valley Road Cleveland OH 44131 5575 m L appareil doit tre aliment par un circuit de 120 V CA seulement 60 Hz 15 prot g par fusible m Si le domicile est quip d un c blage en aluminium suivre les instructions suivantes 1 Connecter une section de c ble en cuivre massif aux conducteurs en queue de cochon 2 Connecter le c blage en aluminium la section ajout e de c blage en cuivre en utilisant des connecteurs et ou des outils sp cialement con us et homologu s UL pour fixer le cuivre l aluminium Appliquer la proc dure recommand e par le fabricant des connecteurs La connexion aluminium cuivre doit tre conforme aux codes locaux et aux pratiques de c blage accept es par l industrie m Le calibre des conducteurs et les connexions doivent tre compatibles avec la demande de courant de l appareil sp cifi e sur la plaque signal tique La plaque signal tique de l appareil est situ e derri re le filtre sur la paroi arri re de la hotte m Le calibre des conducteurs doit satisfaire les exigences de la plus r cente dition de la norme National Electrical Code ANSI NFPA 70 ou de la norme CSA C22 1 94 Code canadien de l lectricit partie 1 et C22 2 n 0 M91 derni re dition et de tous les codes et r glements en vigueur INSTRUCTIONS D INSTALLATION m est recommand que l installation du circuit d vacuation Soi
7. S APPLIQUER DANS VOTRE CAS CETTE GARANTIE VOUS CONF RE DES DROITS JURIDIQUES SP CIFIQUES ET VOUS POUVEZ GALEMENT JOUIR D AUTRES DROITS QUI PEUVENT VARIER D UNE JURIDICTION UNE AUTRE Si vous r sidez l ext rieur du Canada et des 50 tats des tats Unis contactez votre marchand KitchenAid autoris pour d terminer si une autre garantie s applique Si vous avez besoin de service voir d abord la section D pannage du Guide d utilisation et d entretien Apr s avoir v rifi la section D pannage de l aide suppl mentaire peut tre trouv e en v rifiant la section Assistance ou service ou en appelant KitchenAid Aux E U composer le 1 800 422 1230 Au Canada composer le 1 800 807 6777 4 09 Conservez ce manuel et votre recu de vente ensemble pour pte ue Nom du marchand r f rence ult rieure Pour le service sous garantie vous devez pr senter un document prouvant la date d achat ou Adresse d installation Inscrivez les renseignements suivants au sujet de votre gros Num ro de t l phone _ appareil m nager pour mieux vous aider obtenir assistance ou service en cas de besoin Vous devrez connaitre le num ro de mod le et le num ro de s rie au complet Vous trouverez ces renseignements sur la plaque signal tique situ e sur le produit Num ro de mod le Num ro de s rie Date d achat 35 W10267109C T 2011 All rights reserved Registered Trademark TM Trademark
8. et sur votre appareil m nager Assurez vous de toujours lire tous les messages de s curit et de vous y conformer Voici le symbole d alerte de s curit Ce symbole d alerte de s curit vous signale les dangers potentiels de d c s et de blessures graves vous et d autres Tous les messages de s curit suivront le symbole d alerte de s curit et le mot DANGER ou AVERTISSEMENT Ces mots signifient Risque possible de d c s ou de blessure grave si vous ne A DANG ER suivez pas imm diatement les instructions Risque possible de d c s ou de blessure grave si vous A AVERTISSEM ENT ne suivez pas les instructions Tous les messages de s curit vous diront quel est le danger potentiel et vous disent comment r duire le risque de blessure et ce qui peut se produire en cas de non respect des instructions 19 20 IMPORTANTES INSTRUCTIONS DE S CURIT AVERTISSEMENT POUR R DUIRE LE RISQUE D INCENDIE CHOC LECTRIQUE OU DOMMAGES CORPORELS RESPECTER LES INSTRUCTIONS SUIVANTES m Utiliser cet appareil uniquement dans les applications envisag es par le fabricant Pour toute question contacter le fabricant m Avant d entreprendre un travail d entretien ou de nettoyage interrompre l alimentation de la hotte au niveau du tableau de disjoncteurs et verrouiller le tableau de disjoncteurs pour emp cher tout r tablissement accidentel de l alimentation du circuit Lorsqu il n est pas possible de verrou
9. la hotte de cuisini re en place Installation sans d charge l ext rieur recyclage Connecter le circuit d vacuation sur l ouverture de d charge de la hotte Serrer le point de connexion avec des brides Installer les filtres charbon Voir la section Entretien de la hotte R installer les filtres graisse m talliques Voir la section Entretien de la hotte Reconnecter la source de courant lectrique Contr ler le fonctionnement du ventilateur de la hotte et de la lampe Remettre l l ment coulissant de la hotte de cuisini re en place Pour commander des ensembles de rechange voir la section Assistance ou service Une bande en vinyle gris est incluse avec la hotte de cuisini re pour couvrir la partie inf rieure visible du placard 1 Installation de l ensemble de la garniture en vinyle gris facultative Mesurer la distance entre l arri re de la hotte et le mur mesure A es Distance entre l arri re de la hotte et le mur 29 2 Mesurer marquer et d couper la garniture en vinyle gris pour qu elle s ajuste la profondeur du placard d termin e gr ce la mesure A Distance entre l arri re de la hotte et le mur 3 Plier les deux extr mit s de la garniture en vinyle gris de 90 au niveau de l entaille A Entaille 4 Fixer la garniture en vinyle gris au bas de la hotte l aid
10. pan size Always use cookware appropriate for the size of the surface element WARNING TO REDUCE THE RISK OF INJURY TO PERSONS IN THE EVENT OF A RANGE TOP GREASE FIRE OBSERVE THE FOLLOWING m SMOTHER FLAMES with a close fitting lid cookie sheet or metal tray then turn off the burner BE CAREFUL TO PREVENT BURNS If the flames do not go out immediately EVACUATE AND CALL THE FIRE DEPARTMENT NEVER PICK UP A FLAMING PAN you may be burned DO NOT USE WATER including wet dishcloths or towels a violent steam explosion will result Use an extinguisher ONLY if You know you have a class ABC extinguisher and you already know how to operate it The fire is small and contained in the area where it started The fire department is being called You can fight the fire with your back to an exit Based on Kitchen Fire Safety Tips published by NFPA READ AND SAVE THESE INSTRUCTIONS INSTALLATION REOUIREMENTS Gather the required tools and parts before starting installation Read and follow the instructions provided with any tools listed here Tools needed Level m Drill m 1 drill bit m 8 mm nut driver or ratchet m Pencil m Pliers m Wire stripper or utility knife m Tape measure or ruler m Caulking gun and weatherproof caulking compound m Philips screwdriver m Flat blade screwdriver m Saber or keyhole saw m Vent clamps m Metal snips Parts needed m Home power supply cabl
11. should be uniform Cold weather installations An additional back draft damper should be installed to minimize backward cold air flow and a thermal break should be installed to minimize conduction of outside temperatures as part of the vent system The damper should be on the cold air side of the thermal break The break should be as close as possible to where the vent System enters the heated portion of the house Makeup air Local building codes may require the use of makeup air systems when using ventilation systems with greater than specified CFM of air movement The specified CFM varies from locale to locale Consult your HVAC professional for specific requirements in your area Venting Methods This range hood is factory set for venting through the roof or through the wall The vent system needed for installation is not included A6 15 2 cm round vent system is recommended Wall Venting Roof Venting A 6 15 2 cm vent through the roof B Roof cap A 6 15 2 cm vent through the wall B Wall cap Calculate Vent System Length The recommended vent system is 6 15 2 cm round vent with a maximum length of 35 ft 10 7 m For the best performance use no more than three 90 elbows To calculate the length of the system add the equivalent feet meters for each of the vent pieces used in the system Example vent system 6 15
12. used as a night light by opening the screen about 1 2 5 cm Move the light switch to the 0 Off position or close the range hood screen to turn the light Off IMPORTANT Clean the range hood and grease filters frequently according to the following instructions Replace grease filters before operating range hood Be sure light is cool before cleaning the range hood Exterior Surfaces Clean the range hood with a mild detergent and soft cloth To avoid damage to the exterior surface do not use abrasive cleansers or steel wool pads Metal Grease Filters The filters should be washed frequently Place filters in dishwasher or hot soapy water to clean Drain water through edge holes and let each filter dry thoroughly before replacing it To Remove Metal Grease Filters 1 Pull out on the range hood screen to expose the filters 2 Using 2 hands press in the tabs at each end of the metal filter and pull down to remove it 3 Repeat Step 2 for each filter To Replace Metal Grease Filters 1 Using 2 hands insert the metal filter into the filter openings 2 Push the metal filter up and press in both tabs on the ends of the filter When filter is seated release the tabs to lock in place 3 Repeat steps 1 and 2 for each filter Charcoal Filters For Non Vented recirculating Installations The charcoal filters are not washable nor reusable They should b
13. ventilateur et soulever le panneau pour l extraire h D gager le moteur du ventilateur et le faire pivoter de 90 de fa on ce que la sortie d vacuation soit orient e vers l arri re Faire pivoter ensuite le moteur du ventilateur de 180 sur son axe d vacuation de fa on ce que le c t plat du moteur du ventilateur soit orient vers le haut REMARQUE C est la seule fa on de proc der pour que le moteur soit correctement install dans l ouverture A Rotation 90 B Rotation 180 C C t plat du moteur du ventilateur i V rifier que le c blage est correctement install j Placer le c ble d alimentation et son illet au centre de l ouverture de sortie du panneau de montage et repositionner l illet dans son encoche de montage A Oeillet encoche de montage Placer le panneau de montage du ventilateur par dessus la sortie d vacuation et le monter sur le logement de la hotte avec les 12 vis de montage Serrer les vis 1 Tirer le moteur du ventilateur travers l ouverture du panneau de montage du ventilateur et serrer les 4 vis de montage du ventilateur Installation sans d charge l ext rieur recyclage travers le soffite placard Relever les mesures appropri es et tracer une ouverture circulaire d couper dans le soffite en employant la m thode d crite pour la d charge travers le mur Relever les mesures appropri es et tracer l axe central sur le soffit
14. venting method to use roof wall or non vented 3 Select a flat surface for assembling the range hood Place covering over that surface AWARNING Excessive Weight Hazard Use two or more people to move and install range hood Failure to do so can result in back or other injury 4 Using 2 or more people lift range hood onto covered surface Range Hood Cabinet Cutout 1 Determine and clearly mark a centerline on the underside of the cabinet A A Centerline 2 Measure and mark lines as shown for your size of range hood Use a saber saw or keyhole saw to cut an opening through the underside of the cabinet 13 3 5 cm ETES e Ae N gt lt 24 9 cm 30 76 2 cm hood 1258 32 0 cm 36 91 4 cm hood 15 39 7 cm The finished cutout size will be 30 76 2 cm range hood 91316 x 2574 24 9 cm x 64 1 cm 36 91 4 cm range hood 91 6 x 31 24 9 cm x 79 3 cm lf the cabinet bottom is recessed above a support frame wood filler strips need to be installed on the right and left sides of the cutout to provide sides of clearance for the sliding screen Wood filler strips should be flush with or recessed 6 to 1 4 1 6 mm to 3 2 mm from the bottom of the support frame zZ A A Wood filler strips 4 Complete cabinet preparation following the instructions for your type of in
15. 6 Costs associated with the removal from your home of your major appliance for repairs This major appliance is designed to be repaired in the home and only in home service is covered by this warranty 7T Repairs to parts or systems resulting from unauthorized modifications made to the appliance 8 Expenses for travel and transportation for product service if your major appliance is located in a remote area where service by an authorized KitchenAid servicer is not available 9 The removal and reinstallation of your major appliance if it is installed in an inaccessible location or is not installed in accordance with published installation instructions 10 Major appliances with original model serial numbers that have been removed altered or cannot be easily determined This warranty is void if the factory applied serial number has been altered or removed from your major appliance The cost of repair or replacement under these excluded circumstances shall be borne by the customer DISCLAIMER OF IMPLIED WARRANTIES LIMITATION OF REMEDIES CUSTOMER S SOLE AND EXCLUSIVE REMEDY UNDER THIS LIMITED WARRANTY SHALL BE PRODUCT REPAIR AS PROVIDED HEREIN IMPLIED WARRANTIES INCLUDING WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE ARE LIMITED TO ONE YEAR OR THE SHORTEST PERIOD ALLOWED BY LAW KITCHENAID SHALL NOT BE LIABLE FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES SOME STATES AND PROVINCES DO NOT ALLOW THE EXCLUSION OR LIMITATION OF INCI
16. DENTAL OR CONSEQUENTIAL DAMAGES OR LIMITATIONS ON THE DURATION OF IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS SO THESE EXCLUSIONS OR LIMITATIONS MAY NOT APPLY TO YOU THIS WARRANTY GIVES YOU SPECIFIC LEGAL RIGHTS AND YOU MAY ALSO HAVE OTHER RIGHTS WHICH VARY FROM STATE TO STATE OR PROVINCE TO PROVINCE If outside the 50 United States and Canada contact your authorized KitchenAid dealer to determine if another warranty applies If you need service first see the Troubleshooting section of the Use amp Care Guide After checking Troubleshooting you may find additional help by checking the Assistance or Service section or by calling KitchenAid In the U S A call 1 800 422 1230 In Canada call 1 800 807 6777 Keep this book and your sales slip together for future reference You must provide proof of purchase or installation date for in warranty service Write down the following information about your major appliance to better help you obtain assistance or service if you ever need it You will need to know your complete model number and serial number You can find this information on the model and serial number label located on the product 18 9 07 Dealer name Address Phone number Model number Serial number Purchase date S CURIT DE LA HOTTE D ASPIRATION Votre s curit et celle des autres est tr s importante Nous donnons de nombreux messages de s curit importants dans ce manuel
17. HOOD SAFETY Your safety and the safety of others are very important We have provided many important safety messages in this manual and on your appliance Always read and obey all safety messages This is the safety alert symbol This symbol alerts you to potential hazards that can kill or hurt you and others All safety messages will follow the safety alert symbol and either the word DANGER or WARNING These words mean You can be killed or seriously injured if you don t immediately ADANGER follow instructions You can be killed or seriously injured if you don t follow A WARN l N instructions safety messages will tell you what the potential hazard is tell you how to reduce the chance of injury and tell you what can happen if the instructions are not followed IMPORTANT SAFETY INSTRUCTIONS WARNING TO REDUCE THE RISK OF FIRE ELECTRIC SHOCK OR INJURY TO PERSONS OBSERVE THE FOLLOWING Use this unit only in the manner intended by the manufacturer lf you have questions contact the manufacturer Before servicing or cleaning the unit switch power off at service panel and lock the service disconnecting means to prevent power from being switched on accidentally When the service disconnecting means cannot be locked securely fasten a prominent warning device such as a tag to the service panel Installation work and electrical wiring must be done by qualified person s in accordance with all applicable code
18. KitchenAid 30 76 2 CM AND 36 91 4 CM SLIDE OUT VENT HOOD HOTTE D ASPIRATION AVEC MODULE DE COMMANDE EXTRACTIBLE DE 30 76 2 CM ET 36 91 4 CM Table of Contents Table des mati res 2 IMPORTANT READ AND SAVE THESE INSTRUCTIONS FOR RESIDENTIAL USE ONLY IMPORTANT LIRE ET CONSERVER CES INSTRUCTIONS POUR UTILISATION R SIDENTIELLE UNIQUEMENT W10267109C 5 5 3 INSTALLATION REQUIREMENTS 5 Tools andiParts s oua c t h ed eta 5 Location Requirements n ng nnne 5 Venting Requirermernfs c HH HH HH me 6 Electrical Requirements 8 INSTALLATION INSTRUCTIONS mms 8 Prepare LOCatiOD eco ede pepe naeh ero 8 Install Range Hood 11 Electrical Connection 12 Connect the Vent System 12 Optional Gray Vinyl Trim ss 13 Optional Front Trim Kits 13 RANGE HOOD USE eere 14 RANGE HOOD CARE innnrnernennnnnennnnennenennenennnee 15 15 R placing th B l deine 15 WIRING DIAGRAM ngang 16 ASSISTANCE OR SERVICE Sen 17 Mithe USA indita Ee ea eiie rem den ae 17 IN Ca
19. a droite dans le sens horaire pour fixer le filtre sur la grille 6 R installer les filtres graisse m talliques Voir la section Filtres graisse m talliques 32 Interrompre l alimentation de la hotte et laisser l ampoule refroidir Utiliser une ampoule fluorescente de type T8 de 15 watts et de 18 45 7 cm de long 1 D connecter la source de courant lectrique 2 Retirer les vis des attaches du couvercle chaque extr mit du couvercle d clairage Retirer les attaches de couvercle et les conserver avec les vis A A Attaches et vis de couvercle 3 Faire coulisser le couvercle d clairage compl tement vers la droite Abaisser l extr mit gauche du couvercle sous le rebord de soutien et le faire nouveau coulisser vers la gauche pour retirer le couvercle 4 Remplacer l ampoule 5 Remettre le couvercle en position en le faisant coulisser R installer les attaches et les vis de couvercle Serrer les vis SCH MAS DEC BLAGE 33 ASSISTANCE OU SERVICE Lors d un appel pour assistance ou service veuillez connaitre la date d achat le num ro de mod le et le num ro de s rie complets de l appareil Ces renseignements nous aideront mieux r pondre votre demande Si vous avez besoin de pi ces de rechange Si vous avez besoin de commander des pi ces de rechange nous vous recommandons d employer uniquement des pi ces sp cifi es par l usine Les pi
20. all e noire et en aluminium bross m Bande en vinyle gris pour le bas du placard garniture arri re et 3 vis de montage IMPORTANT Observer les dispositions de tous les codes et r glements en vigueur Confier l installation de la hotte un technicien qualifi C est l installateur qu incombe la responsabilit de respecter les distances de s paration exig es sp cifi es sur la plaque signal tique de l appareil La plaque signal tique de l appareil est situ e derri re le filtre de gauche sur la paroi arri re de la hotte Installer la hotte de cuisini re distance de toute zone expos e des courants d air comme fen tres portes et bouches de chauffage Respecter les dimensions indiqu es pour les ouvertures d couper dans les placards Ces dimensions tiennent compte des valeurs minimales des d gagements de s paration Avant d effectuer des d coupages consulter les instructions d installation du fabricant de la table de cuisson cuisini re On doit disposer d une prise de courant lectrique reli e la terre Voir la section Sp cifications lectriques La hotte a t configur e l usine pour une installation avec d charge l ext rieur travers le toit ou le mur Pour une installation sans d charge l ext rieur recyclage voir Installation sans d charge l ext rieur recyclage travers le soffite placard la section Pr paration de l emplacement L ensemble de
21. anel is parallel with the cabinet front 5 Pull house power supply cable through the strain relief into when the screen is pushed in Slide the screen forward the terminal box Tighten the mounting bracket screws so that the range hood 6 Use UL listed wire connectors and connect black wires D is secured to the cabinet together 7 Use UL listed wire connectors and connect white wires A together A Mounting bracket screw Flat blade screwdriver 5 Align the range hood front panel with the cabinet Slide the screen forward Locate the 2 screws on each side and turn them counterclockwise to loosen the screws Adjust the front of the vent vertically 9 5 mm up or down or horizontally 34 19 mm front to back until the front is flush with the A White wires D Black wires cabinet Tighten the screws If it is necessary to adjust the B Green ground screw E Wire connectors given dimensions lower and add or remove the filler strips or C Ground wire redrill mounting holes Fire Hazard A Phillips screwariver B Adjustment screws Electrically ground the blower Use copper wire Connect ground wire to green ground screw in terminal box Failure to do so can result in death fire or electrical shock AWARNING 8 Connect the green or bare ground wire from the home power supply to the green ground screw inside the range hood terminal box Tighten green ground screw Use caulking to sea
22. ce pour r parer ou remplacer les ampoules lectriques de l appareil les filtres air ou les filtres eau Les pi ces consomptibles ne sont pas couvertes par la garantie 3 Les r parations lorsque le gros appareil m nager est utilis des fins autres que l usage unifamilial normal ou lorsque les instructions d installation et ou les instructions de l op rateur ou de l utilisateur fournies ne sont pas respect es 4 Les dommages imputables accident modification usage impropre ou abusif incendie inondation actes de Dieu installation fautive ou installation non conforme aux codes d lectricit ou de plomberie ou l utilisation de pi ces consomptibles ou de produits nettoyants non approuv s par KitchenAid 5 Les d fauts apparents notamment les raflures les bosses fissures ou tout autre dommage au fini du gros appareil m nager moins que ces dommages soient dus des vices de mat riaux ou de fabrication et soient signal s KitchenAid dans les 30 jours suivant la date d achat 6 Les co ts associ s au transport du gros appareil m nager du domicile pour r paration Ce gros appareil m nager est concu pour tre r par domicile et seul le service domicile est couvert par la pr sente garantie 7 Les r parations aux pi ces ou syst mes r sultant d une modification non autoris e faite l appareil 8 Les frais de transport pour le service d un produit si votre gros appareil est situ dans une r
23. ces sp cifi es par l usine conviendront et fonctionneront bien parce qu elles sont fabriqu es avec la m me pr cision utilis e dans la fabrication de chaque nouvel appareil Pour localiser des pi ces sp cifi es par l usine dans votre r gion nous appeler ou t l phoner au centre de service d sign le plus proche Veuillez appeler sans frais le Centre pour l eXp rience de la client le de KitchenAid Canada au 1 800 807 6777 Nos consultants vous renseigneront sur les sujets suivants m Caract ristiques et sp cifications sur toute notre gamme d appareils lectrom nagers Consignes d utilisation et d entretien Vente d accessoires et de pi ces de rechange R f rences aux marchands locaux aux distributeurs de pi ces de rechange et aux compagnies de service Les techniciens de service d sign s par KitchenAid Canada sont form s pour remplir la garantie des produits et fournir un service apr s la garantie partout au Canada 34 Pour plus d assistance Si vous avez besoin de plus d assistance vous pouvez soumettre par crit toute question ou pr occupation KitchenAid Canada l adresse suivante Centre pour l eXp rience de la client le KitchenAid Canada 200 6750 Century Ave Mississauga Ontario L5N 0B7 Veuillez inclure dans votre correspondance un num ro de t l phone o l on peut vous joindre dans la journ e Ensemble de recyclage pour installations sans d charge l ext rieur uniq
24. d incendie et vacuer ad quatement les gaz veiller acheminer l air aspir par un conduit jusqu l ext rieur ne pas d charger l air aspir dans un espace vide du b timent comme une cavit murale un plafond un grenier un vide sanitaire ou un garage AVERTISSEMENT POUR R DUIRE LE RISQUE D INCENDIE UTILISER UNIQUEMENT DES CONDUITS M TALLIQUES AVERTISSEMENT POUR MINIMISER LE RISQUE D UN FEU DE GRAISSE SUR LA CUISINI RE m Ne jamais laisser un l ment de surface fonctionner puissance de chauffage maximale sans surveillance Un renversement d bordement de mati re graisseuse pourrait provoquer une inflammation et la g n ration de fum e Utiliser une puissance de chauffage moyenne ou basse pour le chauffage d huile Veiller toujours faire fonctionner le ventilateur de la hotte lors de la cuisson avec une puissance de chauffage lev e ou lors de la cuisson d un mets flamber savoir cr pes Suzette cerise jubil e steak au poivre flamb Nettoyer fr quemment les ventilateurs d extraction Veiller ne pas laisser la graisse s accumuler sur les surfaces du ventilateur ou des filtres Utiliser toujours un ustensile de taille appropri e Utiliser toujours un ustensile adapt la taille de l l ment chauffant AVERTISSEMENT POUR R DUIRE LE RISQUE DE DOMMAGES CORPORELS APR S LE D CLENCHEMENT D UN FEU DE GRAISSE SUR LA CUISINI RE APPLIQUER LES RECOMMANDATIONS SUIVANTES m Plac
25. e m Two 12 7 mm UL listed or CSA approved strain reliefs For vented installations you will also needed m 1 wall or roof cap m Metal vent system For non vented recirculating installations you will also need m Recirculation Kit Part Number 4396565 See Assistance or Service section to order Optional parts needed m Wood filler strips for cabinets with recessed bottoms Length and thickness determined by recess dimensions See Prepare Location section m Two 1 x 1 x 5 25 4 x 25 4 x 127 mm wood pieces for cabinet floor See Prepare Location section m Four 1 31 8 mm wood screws Parts supplied Remove parts from packages Check that all parts are included 2 screws used for mounting the vent grate Damper Plastic cover used for customized front trim Hardware package Vent grate for non vented recirculating installations Front trim White installed Black and Brushed Aluminum Gray vinyl strip used for bottom of cabinet rear trim and 3 mounting screws IMPORTANT Observe all governing codes and ordinances Have a qualified technician install the range hood It is the installer s responsibility to comply with installation clearances specified on the model serial rating plate The model serial rating plate is located behind the left filter on the rear wall of the range hood Range hood location should be away from strong draft areas such as windows doors and strong heati
26. e au dessus de la zone de la hotte A Couvercle du conduit d vacuation Axe central Utiliser le couvercle d vent fourni avec la hotte ou un autre couvercle comme gabarit pour tracer l ouverture pour le conduit d vacuation Utiliser une scie sauteuse ou scie guichet pour d couper une ouverture circulaire pour le passage du circuit d vacuation L air aspir par la hotte peut tre d charg l int rieur travers le sommet du placard en 15 9 cm 1 Ouverture Pour une installation sans d charge l ext rieur recyclage l installation de filtres charbon est n cessaire Voir la section Entretien de la hotte pour des instructions sur l installation de filtres au charbon 4 10 5 On doit utiliser l ensemble de recyclage pi ce num ro 4396565 Installer le circuit d vacuation selon la m thode requise Utiliser un calfeutrant pour assurer l tanch it au point de travers e du mur ext rieur ou du toit Acheminer le c blage travers le mur ou le placard veiller respecter les prescriptions du Code de l lectricit et de tous les codes et r glements locaux Utiliser un calfeutrant pour assurer l tanch it au point de travers e du c blage 9 10 Mesurer l paisseur du plancher du placard en incluant les tringles d appui en bois si celles ci sont utilis es Si l paisseur est inf rieure 4 15 9 mm in
27. e changed every 6 months in normal use or more frequently in heavy use To order new charcoal filters see the Assistance or Service section The charcoal filters capture unpleasant cooking odors To Install Replace Charcoal Filters 1 Turn fan and lights off 2 Remove all 4 metal grease filters See Metal Grease Filters section 3 Set metal grease filters aside 4 Rotate to the left counterclockwise and pull away from the blower cover and discard filter pack Repeat for other filter A Filter 5 Place the charcoal filter against the blower cover and rotate to the right clockwise to attach to cover 6 Replace metal grease filters See Metal Grease Filters section Turn off the range hood and allow the bulb to cool Use an 18 45 7 cm long 15 watt type T8 fluorescent bulb 1 Disconnect power 2 Remove the screws from the cover clips at each end of the light cover Remove the cover clips and set them aside with the screws A A Cover clips and screws 3 Slide the light cover all the way to the right Lower the left end of the cover below the support flange and slide it back to the left to remove the cover 4 Replace the light bulb 5 Slide the cover back into position Reinstall the cover clips and screws Tighten the screws 15 WIRING DIAGRAM ASSISTANCEOR SERVICE When calling for assistance or service please know the purchase date and the complete model and se
28. e des trois vis fournies C D E A Placard B Mur C Garniture en vinyle gris D Vis 3 E Bas de la hotte Des garnitures avant blanche noire et en aluminium bross sont fournies avec la hotte pour pouvoir assortir le panneau avant la cuisini re ou la table de cuisson La garniture blanche est pr install e Suivre les instructions suivantes pour installer une garniture de couleur diff rente Installation de l ensemble de garniture avant 1 Extraire l l ment coulissant de la hotte de cuisini re pour pouvoir acc der aux vis 2 Enlever les filtres graisse m talliques Voir la section Entretien de la hotte 30 3 ter les 3 vis de montage situ es directement derri re le panneau avant A Trois vis de montage 4 Retirer la garniture existante et installer la nouvelle pi ce 5 Fixer la nouvelle garniture au panneau avant l aide des 3 vis de montage Serrer les vis 6 R installer les filtres graisse m talliques Voir la section Entretien de la hotte 7 Remettre l l ment coulissant de la hotte de cuisini re en place UTILISATION DELA HOTTE La hotte de cuisini re est congue pour extraire fum e vapeurs de cuisson et odeurs de la zone de la table de cuisson Pour des r sultats optimaux mettre la hotte en marche avant d entreprendre une cuisson et la laisser fonctionner pendant plusieurs min
29. e mur Le syst me de d charge requis pour l installation n est pas fourni L utilisation d un circuit d vacuation circulaire de 6 15 2 cm est recommand e D charge travers le toit me TE y D charge travers le mur A Conduit de 6 15 2 cm travers le toit B Bouche de d charge travers le toit A Conduit de 6 15 2 cm travers le mur B Bouche de d charge murale Calcul de la longueur effective du circuit d vacuation On recommande une longueur du circuit d vacuation de 6 15 2 cm avec un maximum de 35 pi 10 7 Pour une performance optimale ne pas utiliser plus de trois coudes 90 Pour calculer la longueur effective du circuit d vacuation n cessaire additionner les longueurs quivalentes en pieds m tres de tous les composants utilis s dans le circuit Composant 6 15 2 cm Coude 45 2 5 pi 0 8 m I Coude 90 5 pi 1 5 m Exemple de circuit de d charge 6 15 2 cm n Bouche de d charge murale Coude 90 lt 6 pi 1 8 m ow 80 gt E Longueur maximum 35 pi 10 7 1 coude 90 5pi 1 5 1 bouche de 0 pi 0 0 m d charge murale section droite de 9 pi 9 pi 2 8 m 2 8 m Longueur totale 14 pi 4 3 m Installations sans d charge l ext rieur recyclage travers le soffite placard S il n est pas possible d vacuer les
30. er sur le r cipient un couvercle bien ajust une t le biscuits ou un plateau m tallique POUR ETOUFFER LES FLAMMES puis teindre le br leur VEILLER A EVITER LES BRULURES Si les flammes ne s teignent pas imm diatement EVACUER LA PIECE ET APPELER LES POMPIERS NE JAMAIS PRENDRE EN MAIN UN R CIPIENT ENFLAMME vous risquez de vous br ler NE PAS UTILISER D EAU ni un torchon humide ceci pourrait provoquer une explosion de vapeur br lante Utiliser un extincteur SEULEMENT si Il s agit d un extincteur de classe ABC dont on connait le fonctionnement Il s agit d un petit feu encore limit l endroit o il s est d clar Les pompiers ont t contact s est possible de garder le dos orient vers une sortie pendant l op ration de lutte contre le feu Recommandations tir es des conseils de s curit en cas d incendie de cuisine publi s par la NFPA LIRE ET CONSERVER CES INSTRUCTIONS EXIGENCES D INSTALLATION Rassembler les outils et composants n cessaires avant d entreprendre l installation Lire et observer les instructions fournies avec chacun des outils num r s ci dessous Outils n cessaires Niveau Perceuse Foret de 11 4 Tourne crou ou cl cliquet de 8 0 mm Crayon Pince Pince d nuder ou couteau utilitaire M tre ruban ou r gle Pistolet calfeutrage et compos de calfeutrage r sistant aux intemp ries Tournevis Phillips Tour
31. ervice company This limited warranty is valid only in the United States or Canada and applies only when the major appliance is used in the country in which it was purchased Outside the 50 United States and Canada this limited warranty does not apply Proof of original purchase date is required to obtain service under this limited warranty ITEMS EXCLUDED FROM WARRANTY This limited warranty does not cover 1 Service calls to correct the installation of your major appliance to instruct you on how to use your major appliance to replace or repair house fuses or to correct house wiring or plumbing 2 Service calls to repair or replace appliance light bulbs air filters or water filters Consumable parts are excluded from warranty coverage 3 Repairs when your major appliance is used for other than normal single family household use or when it is used in a manner that is contrary to published user or operator instructions and or installation instructions 4 Damage resulting from accident alteration misuse abuse fire flood acts of God improper installation installation not in accordance with electrical or plumbing codes or use of consumables or cleaning products not approved by KitchenAid 5 Cosmetic damage including scratches dents chips or other damage to the finish of your major appliance unless such damage results from defects in materials or workmanship and is reported to KitchenAid within 30 days from the date of purchase
32. fum es et vapeurs de cuisson l ext rieur on peut employer la version installation sans d charge l ext rieur recyclage de la hotte dot e d un filtre charbon actif L ensemble de recyclage pi ce num ro 4396565 est disponible chez votre marchand ou chez un distributeur de pi ces autoris L installation d un clapet anti reflux n est pas n cessaire A A ur 2 B 4 7 gt B E wh lt F D i i E E A Plafond B Couvercle du conduit d vacuation C Soffite D Conduit de 6 15 2 cm E Hotte de cuisini re F Placard 23 Observer les dispositions de tous les codes et r glements vigueur V rifier que l installation lectrique a t correctement effectu e et qu elle est conforme aux sp cifications de la plus r cente dition des normes National Electrical Code ANSI NFPA 70 ou de la norme CSA C22 1 94 Code canadien de l lectricit partie 1 et C22 2 N 0 M91 derni re dition et de tous les codes et r glements en vigueur locaux Si les codes le permettent et si on utilise un conducteur distinct de liaison la terre il est recommand qu un lectricien qualifi v rifie la qualit de la liaison la terre Pour obtenir un exemplaire de la norme des codes ci dessus contacter National Fire Protection Association One Batterymarch
33. gion loign e un service d entretien KitchenAid autoris n est pas disponible 9 La d pose et la r installation de votre gros appareil si celui ci est install dans un endroit inaccessible ou n est pas install conform ment aux instructions d installation fournies 10 Les gros appareils m nagers dont les num ros de s rie et de mod le originaux ont t enlev s modifi s ou qui ne peuvent pas tre facilement identifi s La pr sente garantie est nulle si le num ro de s rie d usine a t modifi ou enlev du gros appareil m nager Le co t d une r paration ou d un remplacement dans le cadre de ces circonstances exclues est la charge du client CLAUSE D EXON RATION DE RESPONSABILIT AU TITRE DES GARANTIES IMPLICITES LIMITATION DES RECOURS LE SEUL ET EXCLUSIF RECOURS DU CLIENT DANS LE CADRE DE LA PR SENTE GARANTIE LIMIT E CONSISTE EN LA R PARATION PR VUE CI DESSUS LES GARANTIES IMPLICITES Y COMPRIS LES GARANTIES APPLICABLES DE QUALIT MARCHANDE ET D APTITUDE UN USAGE PARTICULIER SONT LIMIT ES UN AN OU LA PLUS COURTE P RIODE AUTORIS E PAR LA LOI KITCHENAID N ASSUME AUCUNE RESPONSABILIT POUR LES DOMMAGES FORTUITS OU INDIRECTS CERTAINES JURIDICTIONS NE PERMETTENT PAS L EXCLUSION OU LA LIMITATION DES DOMMAGES FORTUITS OU INDIRECTS OU LES LIMITATIONS DE LA DUREE DES GARANTIES IMPLICITES DE QUALITE MARCHANDE OU D APTITUDE A UN USAGE PARTICULIER DE SORTE QUE CES EXCLUSIONS OU LIMITATIONS PEUVENT NE PAS
34. he REMARQUE Si l interrupteur d clairage est laiss la position 1 marche la lumi re s allumera chaque fois que l on ouvrira l l ment coulissant On peut aussi utiliser l clairage comme source d clairage nocturne en ouvrant l l ment coulissant d environ 1 2 5 cm 3 Placer l interrupteur d clairage la position O arr t ou fermer l l ment coulissant de la hotte pour teindre la lumi re ENTRETIEN DELA HOTTE IMPORTANT Nettoyer fr quemment la hotte et les filtres graisse en suivant les instructions suivantes R installer les filtres graisse avant de faire fonctionner la hotte Avant d entreprendre le nettoyage de la hotte attendre le refroidissement de la lampe Surfaces externes Nettoyer la hotte avec un d tergent doux et un chiffon doux Afin d viter d endommager la surface externe ne pas utiliser de nettoyants abrasifs ou de tampons en laine d acier Filtres graisse m talliques Les filtres doivent tre lav s fr quemment Laver les filtres au lave vaisselle ou avec une solution d eau savonneuse chaude Laisser l eau s couler travers les trous des bords de chaque filtre et s cher parfaitement chaque filtre avant de le r installer D pose des filtres graisse m talliques 1 Sortir l l ment coulissant de la hotte de cuisini re pour exposer les filtres 2 Avecles 2 mains appuyer sur les onglets chaque extr mit du filtre m tallique et tirer vers
35. iller le tableau de disjoncteurs placer sur le tableau de disjoncteurs une tiquette d avertissement pro minente interdisant le r tablissement de l alimentation m Tout travail d installation ou c blage lectrique doit tre r alis par une personne qualifi e dans le respect des prescriptions de tous les codes et normes applicables y compris les codes du b timent et de protection contre les incendies m Une source d air de d bit suffisant est n cessaire pour le fonctionnement correct de tout appareil gaz combustion et vacuation des gaz combustion par la chemin e pour qu il n y ait pas de reflux des gaz de combustion Respecter les directives du fabricant de l quipement de chauffage et les prescriptions des normes de s curit comme celles publi es par la National Fire Protection Association NFPA et l American Society for Heating Refrigeration and Air Conditioning Engineers ASHRAE et les prescriptions des autorit s r glementaires locales Lors d op rations de d coupage et de percage dans un mur ou un plafond veiller ne pas endommager les c blages lectriques ou canalisations qui peuvent s y trouver Les ventilateurs d vacuation doivent toujours d charger l air l ext rieur MISE EN GARDE Cet appareil est congu uniquement pour la ventilation g n rale Ne pas l utiliser pour l extraction de mati res ou vapeurs dangereuses ou explosives MISE EN GARDE Pour minimiser le risque
36. ion assurer l tanch it avec les brides de serrage m l aide d un produit de calfeutrage assurer l tanch it autour de la bouche de d charge l ext rieur travers le mur ou le toit m Lataille du conduit doit tre uniforme Installations r gions climat froid On doit installer un clapet anti reflux suppl mentaire l arri re pour minimiser le reflux d air froid et incorporer un l ment d isolation thermique pour minimiser la conduction de chaleur par l interm diaire du conduit d vacuation de l int rieur de la maison l ext rieur Le clapet anti reflux doit tre plac du c t air froid par rapport l l ment d isolation thermique L l ment d isolation thermique doit tre aussi proche que possible de l endroit o le circuit d vacuation s introduit dans la partie chauff e de la maison Air d appoint Les codes locaux du b timent peuvent exiger l emploi d un syst me de renouvellement de l air introduction d air d appoint lors de l utilisation d un syst me d aspiration de d bit sup rieur une valeur pieds cubes par minute sp cifi e Le d bit sp cifi en pieds cubes par minute varie d une juridiction l autre Consulter un professionnel des installations de CVCA au sujet des exigences sp cifiques applicables dans votre juridiction locale M thodes d vacuation Cette hotte a t configur e l usine pour la d charge travers le toit ou travers l
37. l around wire opening 9 Tighten strain relief screw 10 Install terminal box cover NOTE Do not turn on power until installation is complete Electrical Shock Hazard Disconnect power before servicing Replace all parts and panels before operating Failure to do so can result in death or electrical shock Vented Installations 1 Disconnect power 2 Remove terminal box cover 1 Replace the metal filters See Range Hood Care section 3 Remove knockout from top of the terminal box and install a 2 Connect the vent system to the range hood vent openin UL listed or CSA approved 1 2 strain relief Seal the ee with clamps 9 P 9 4 Determine the location and mount the terminal box to the 3 Reconnect power inside of the cabinet or wall using the 4 mounting holes in the of the terminal box The mounting screws not 4 Check the operation of the range hood fan and light supplied 5 Push the range hood screen back in 12 Non Vented recirculating Installations 1 Connect the vent system to the range hood vent opening Seal the connection with clamps 2 Install charcoal filters See Range Hood Care section 3 Replace metal grease filters See Range Hood Care section 4 Reconnect power 5 Check the operation of the range hood fan and light 6 Push the range hood screen back in To order replacement kits see the Assistance or Service section A gray vinyl trim strip i
38. lacard O 33 cm sup et plan de travail s D 15 38 1 cm i m min M nM CT m d du bas 36 01 4 T 22 10 25 4 cm 19e 4 0 cm 41 27 9 cm il 18 45 7 cm avec l ment coulissant d ploy m Le circuit d vacuation doit d charger l air l ext rieur except pour les installations sans d charge l ext rieur recyclage m pas terminer le circuit d vacuation dans un grenier ou dans un autre espace ferm m Ne pas utiliser une bouche de d charge murale de 4 10 2 cm normalement utilis e pour un quipement de buanderie m Utiliser un conduit m tallique uniquement Un conduit en m tal rigide est recommand Ne pas utiliser de conduit de plastique ou en feuille m tallique m Lalongueur du syst me d vacuation et le nombre de coudes doit tre r duit au minimum pour une performance efficace Pour un fonctionnement efficace et silencieux m Ne pas utiliser plus de trois coudes 90 m Veiller ce qu il y ait une section droite de conduit d un minimum de 24 61 0 cm entre les raccords coud s si on doit en utiliser plus d un Ne pas installer 2 coudes ensemble Le circuit d vacuation doit comporter un clapet anti reflux Si la bouche de d charge murale ou par le toit comporte un clapet anti reflux ne pas utiliser le clapet fourni avec la hotte de cuisini re m Auniveau de chaque jointure du circuit d vacuat
39. le bas pour le retirer 3 R p ter l tape 2 pour chaque filtre Is s R installation des filtres graisse m talliques 1 Avec les 2 mains ins rer le filtre m tallique dans les ouvertures du filtre 2 Soulever le filtre m tallique et appuyer sur les deux onglets situ s aux extr mit s du filtre Une fois le filtre en place rel cher les onglets pour enclencher le filtre 3 R p ter les tapes 1 et 2 pour chaque filtre 31 Filtres charbon Installation sans d charge l ext rieur recyclage Les filtres charbon ne sont pas lavables ni r utilisables Ils doivent tre remplac s tous les 6 mois en cas d utilisation normale ou plus fr quemment en cas d utilisation intense Pour commander de nouveaux filtres charbon voir la section Assistance ou service Les filtres charbon retiennent les compos s responsables des odeurs de cuisson Installation remplacement des filtres charbon 1 Eteindre le ventilateur et les lampes 2 ter les 4 filtres graisse m talliques Voir la section Filtres graisse m talliques 3 Mettre les filtres graisse m talliques de c t 4 Faire pivoter le filtre vers la gauche dans le sens antihoraire le d gager de la grille du ventilateur et jeter les vieux filtres R p ter pour l autre filtre S A Filtre 5 Placer le filtre charbon contre la grille du ventilateur faire pivoter vers l
40. les 2 vis de part et d autre les faire tourner dans le sens antihoraire et les desserrer Ajuster l avant de la hotte en position verticale de 36 9 5 mm vers le haut ou vers le bas ou horizontalement de 34 19 mm d avant en arri re jusqu ce que l avant soit en affleurement avec le placard Serrer les vis S il est n cessaire d ajuster les dimensions indiqu es modifier l paisseur des tringles d appui ou repercer des trous de montage A Tournevis Phillips B Vis de r glage AVERTISSEMENT D Risque de choc lectrique D connecter la source de courant lectrique avant l entretien Replacer pieces et panneaux avant de faire la remise en marche Le non respect de ces instructions peut causer un d c s ou un choc lectrique D connecter la source de courant lectrique ter le couvercle du boitier de connexion ter l opercule arrachable du couvercle du boitier de connexion et installer un serre c ble de 1 2 homologation UL ou CSA 4 D terminer l emplacement du bo tier de connexion et le fixer l int rieur du placard ou au mur en utilisant les 4 trous de montage situ s l arri re du bo tier de connexion Les vis de montage ne sont pas fournies 5 Tirer le c ble d alimentation du domicile travers le serre c ble jusque dans le bo tier de connexion 6 Connecter ensemble les conducteurs noirs D l aide de connecteurs de fils homologation UL
41. les d appui en bois le cas ch ant Marquer le p rim tre de l ouverture d couper voir l illustration Utiliser une scie sauteuse ou scie guichet pour d couper une ouverture circulaire pour le passage du conduit d vacuation A Mesure B Axe central C Ouverture d coup e circulaire de 6 15 9 cm 25 Modification de la hotte pour vacuation par l arri re facultative La hotte sort de l usine avec le raccord de sortie situ sur la partie sup rieure de la hotte La bouche de d charge de la hotte peut tre orient e pour une vacuation par l arri re de la hotte travers le raccord de sortie vacuation par l arri re Si l on souhaite une vacuation par l arri re de la hotte suivre la proc dure suivante 26 a Placer la hotte sur le dos b Retirer les filtres m talliques Voir la section Entretien de la hotte c Couper l attache m tallique du faisceau de c blage d Replacer la hotte en position verticale e Maintenir le moteur du ventilateur pour l emp cher de tomber lors du retrait des 4 vis fixant le ventilateur d vacuation la hotte Abaisser le moteur de ventilateur avec pr caution f Retirer le c ble d alimentation et son illet du panneau A Cordon d alimentation lectrique et ceillet B Panneau de montage du ventilateur g Retirer les 12 vis du panneau de montage du
42. nada eee Reais eines terit tend 17 ACCESSES ssi ine RE Li Ni 17 WARBRANTY iren eiiis 18 TABLE DES MATI RES S CURIT DE LA HOTTE D ASPIRATION 19 EXIGENCES D INSTALLATION lt lt lt 7 lt lt s ee 21 Outils et composants SH SH HH HH 21 Exigences d emplacement 21 Exigences concernant l vacuation 22 Sp cifications lectriques sess 24 INSTRUCTIONS 24 Pr paration de l emplacement 24 Installation de la hotte 28 Raccordement lectrique 28 Raccordement du circuit 29 Garniture en vinyle gris facultative 29 Ensembles de garniture avant facultatifs 30 UTILISATION DE LA HOT TEE lt 7 lt lt lt ss eer 30 ENTRETIEN DE LA 31 Nettoyage uen eEeereadetesed ente 31 Remplacement de l ampoule VV 32 SCHEMAS DE eerte 33 ASSISTANCE OU SERVICE 7S 34 AU CANAL ten tecti eere niic 34 ACCOSSOILOS 2 5 nn T nr ne ce 34 GARANTIE 35 RANGE
43. nevis lame plate Scie sauteuse ou scie guichet Brides de serrage pour conduit d vacuation Cisaille de ferblantier Pi ces n cessaires m d alimentation lectrique du domicile m Deux serre c ble approuv s de 1 2 12 7 mm homologation UL ou CSA Pour les installations avec d charge l ext rieur il faudra aussi m 1 bouche de d charge d charge travers le mur ou travers le toit m Circuit d vacuation m tallique Pour les installations sans d charge l ext rieur recyclage il faudra aussi m Ensemble de recyclage pi ce num ro 4396565 Voir Assistance ou service pour commander Pi ces facultatives ventuellement n cessaires m Tringles d appui en bois pour placards avec fond en retrait Longueur et paisseur selon les dimensions de l encastrement Voir la section Pr paration de l emplacement m Deux tringles de bois 1 x 1 x 5 25 4 x 25 4 x 127 0 mm pour le plancher du placard Voir la section Pr paration de l emplacement m Quatre vis bois 1 31 8 mm Pi ces fournies Retirer les pi ces des emballages V rifier que toutes les pi ces sont pr sentes 2 vis pour l installation de la grille d vacuation m Clapet m Feuille de protection en plastique pour garniture avant personnalis e Sachet de quincaillerie Grille d vacuation pour les installations sans d charge l ext rieur recyclage m Garniture avant blanche pr inst
44. ng vents Cabinet opening dimensions that are shown must be used Given dimensions provide minimum clearance Consult your cooktop range manufacturer installation instructions before making any cutouts Grounded electrical outlet is required See Electrical Requirements section The range hood is factory set for vented installations through the roof or wall For non vented recirculating installations see Non Vented recirculating Installation Through the Soffit Cabinet in the Prepare Location section Recirculation Kit Part Number 4396565 is available from your dealer or an authorized parts distributor All openings in ceiling and wall where range hood will be installed must be sealed For Mobile Home Installations The installation of this range hood must conform to the Manufactured Home Construction Safety Standards Title 24 CFR Part 328 formerly the Federal Standard for Mobile Home Construction and Safety title 24 HUD Part 280 or when such standard is not applicable the standard for Manufactured Home Installation 1982 Manufactured Home Sites Communities and Setups ANSI A225 1 NFPA 501A or latest edition or with local codes Product Dimensions 173 44 1 cm 30 76 2 cm model 239 59 4 cm 36 91 4 cm model 6 15 2 cm 1 6 em 10 25 4 cm 34 1 9 cm 19 6 4 0 cm 25 64 1 cm 30 76 2 cm model 1 79 4 cm 36 91 4 cm model 291 75 9 cm
45. ode standards can be obtained from National Fire Protection Association One Batterymarch Park Quincy MA 02269 CSA International 8501 East Pleasant Valley Road Cleveland OH 44131 5575 m 120 volt 60 Hz AC only 15 amp fused electrical circuit is required m If the house has aluminum wiring follow the procedure below 1 Connect a section of solid copper wire to the pigtail leads 2 Connect the aluminum wiring to the added section of copper wire using special connectors and or tools designed and UL listed for joining copper to aluminum Follow the electrical connector manufacturer s recommended procedure Aluminum copper connection must conform with local codes and industry accepted wiring practices m Wire sizes and connections must conform with the rating of the appliance as specified on the model serial rating plate The model serial plate is located behind the filter on the rear wall of the range hood m Wire sizes must conform to the requirements of the National Electrical Code ANSI NFPA 70 latest edition or CSA Standards C22 1 94 Canadian Electrical Code Part 1 and C22 2 No 0 M91 latest edition and all local codes and ordinances INSTALLATION INSTRUCTIONS m ltis recommended that the vent system be installed before the range hood is installed m Before making cutouts make sure there is proper clearance within the ceiling or wall for vent fittings Disconnect power Determine which
46. of KitchenAid U S A KitchenAid Canada licensee in Canada Printed in Italy Tous droits r serv s Marque d pos e TM Marque de commerce de KitchenAid U S A Emploi sous licence par KitchenAid Canada au Canada Imprim en Italie
47. otte de 36 91 4 cm 91 6 x 31 24 9 cm x 79 3 cm 3 S le fond du placard forme une cavit au dessus d un cadre de support on devra installer des tringles d appui en bois droite et gauche de l ouverture d coup e afin de laisser suffisamment d espace pour pouvoir man uvrer l l ment coulissant Les tringles d appui en bois doivent tre en affleurement ou en retrait de 6 1 4 1 6 mm 3 2 mm par rapport au fond du cadre de support A Tringles d appui en bois 4 Terminer la pr paration du placard conform ment aux instructions selon le type d installation D charge l ext rieur travers le toit Relever les mesures appropri es et tracer les lignes indiqu es sur l illustration Utiliser une scie sauteuse ou scie guichet pour d couper une ouverture circulaire pour le passage du conduit d vacuation 6 15 9 cm D charge l ext rieur travers le mur Assembler le circuit d vacuation qui sera utilis sur l ouverture de d charge Ne pas raccorder le circuit d vacuation la hotte tout de suite Mesurer la distance entre le sommet du logement du filtre et l axe central horizontal de l ouverture d vacuation A Enlever le conduit d vacuation A Mesure Reporter la dimension A sur la paroi arri re du placard Mesurer depuis la face inf rieure du placard ou la face inf rieure des tring
48. ower to the range hood Gently lower blower motor down f Remove the power supply cable and grommet from the panel A Power supply cord and grommet B Blower mounting panel g Remove the 12 screws from the blower mounting panel and lift off the panel h Pull out on the blower motor and rotate it 90 so that the exhaust outlet is pointing out the back Then rotate the blower motor around its exhaust axis 180 so the flat side of the blower motor is pointed up NOTE This is the only way the blower motor will fit properly in the opening Rotate 90 B Rotate 180 C Flat side of blower motor i Check that the wiring is properly positioned j Place the power supply cable and grommet through the center of the outlet hole opening in the mounting panel and reposition the grommet into its mounting notch A Grommet mounting notch k Place the blower mounting panel over the exhaust outlet and mount it onto the hood housing with the 12 mounting screws Tighten the screws 1 Pull the blower motor out through the opening in the blower mounting panel and fasten with the 4 blower mounting screws 10 Non Vented recirculating Installation Through the Soffit Cabinet Measure and mark a round vent opening in the soffit using the method shown for venting through the wall Measure and mark the centerline on the soffit above the range hood area A Vent cover B Centerline Use the ven
49. recyclage pi ce num ro 4396565 est disponible chez votre marchand ou chez un distributeur de pi ces autoris Assurer l tanch it au niveau de chaque ouverture d coup e dans le plafond ou le mur pour l installation de la hotte de cuisini re Installation dans une r sidence mobile L installation de cette hotte doit satisfaire aux exigences de la norme Manufactured Home Construction Safety Standards Titre 24 CFR partie 328 anciennement Federal Standard for Mobile Home Construction and Safety titre 24 HUD partie 280 lorsque cette norme n est pas applicable l installation doit satisfaire aux crit res de la plus r cente dition de la norme Manufactured Home Installation 1982 Manufactured Home Sites Communities and Setups ANSI A225 1 NFPA 501A ou des codes locaux 21 Dimensions du produit 173 44 1 cm mod le de 30 76 2 cm 23 59 4 cm mod le de 36 91 4 cm 6 15 2 cm 5 1 6 cm 34 1 9 cm 25 64 1 cm mod le de 30 76 2 cm 31 79 4 cm mod le de 36 91 4 cm 297 75 9 cm mod le de 30 76 2 cm 3574 91 1 cm mod le de 36 91 4 cm Dimensions du placard lt Largeur de l ouverture du placard 30 76 2 cm ou 36 91 4 cm min Distance sugg r e du bas du placard la surface de cuisson LL CET 76 2 cm max S S eal D gagament entre p
50. rial number of your appliance This information will help us to better respond to your request If you need replacement parts If you need to order replacement parts we recommend that you use only factory specified parts Factory specified parts will fit right and work right because they are made with the same precision used to build every new appliance To locate factory specified replacement parts in your area call us or your nearest designated service center Call the KitchenAid Customer eXperience Center toll free 1 800 422 1230 Our consultants provide assistance with Features and specifications on our full line of appliances Installation information Use and maintenance procedures Accessory and repair parts sales Specialized customer assistance Spanish speaking hearing impaired limited vision etc m Referrals to local dealers repair parts distributors and service companies KitchenAid designated service technicians are trained to fulfill the product warranty and provide after warranty service anywhere in the United States To locate the KitchenAid designated service company in your area you can also look in your telephone directory Yellow Pages For further assistance If you need further assistance you can write to KitchenAid with any questions or concerns at KitchenAid Brand Home Appliances Customer eXperience Center 553 Benson Road Benton Harbor MI 49022 2692 Please include a daytime phone n
51. s and standards including fire rated construction Sufficient air is needed for proper combustion and exhausting of gases through the flue chimney of fuel burning equipment to prevent backdrafting Follow the heating equipment manufacturer s guideline and safety standards such as those published by the National Fire Protection Association NFPA the American Society for Heating Refrigeration and Air Conditioning Engineers ASHRAE and the local code authorities When cutting or drilling into wall or ceiling do not damage electrical wiring and other utilities Ducted fans must always be vented outdoors CAUTION For general ventilating use only Do not use to exhaust hazardous or explosive materials and vapors CAUTION To reduce risk of fire and to properly exhaust air be sure to duct air outside do not vent exhaust air into spaces within walls or ceilings attics or into crawl spaces or garages WARNING TO REDUCE THE RISK OF FIRE USE ONLY METAL DUCTWORK WARNING TO REDUCE THE RISK OF A RANGE TOP GREASE FIRE m Never leave surface units unattended at high settings Boilovers cause smoking and greasy spillovers that may ignite Heat oils slowly on low or medium settings m Always turn hood ON when cooking at high heat or when flambeing food i e Crepes Suzette Cherries Jubilee Peppercorn Beef Flamb m Clean ventilating fans frequently Grease should not be allowed to accumulate on fan or filter m Use proper
52. s included with the range hood to cover the exposed underside of the cabinet Install Optional Gray Vinyl Trim Kit 1 Measure the distance from the back of the range hood to the wall measurement A A Distance from back of the range hood to the wall 2 Measure mark and cut the gray vinyl trim to fit the cabinet depth determined by measurement A pes l A Distance from back of the range hood to the wall 3 Fold both ends of the gray vinyl trim up 90 at the score l L 1 A A Score Attach the gray vinyl trim to the bottom of the range hood using the 3 screws provided J rx e B T C D E A Cabinet B Wall C Gray vinyl trim D Screws 3 E Bottom of range hood White black and brushed aluminum front trim for matching the front panel to your range or cooktop color are included with the range hood The white trim is installed See following instructions to install a different trim color Install Front Trim Kit Pull out on the range hood screen for access to the screws Remove metal grease filters See Range Hood Care section Remove the 3 mounting screws directly behind the front panel A Three mounting screws Remove existing trim piece and insert new trim piece Attach the new trim piece to the front panel using the 3 mounting screws Tighten the screws
53. stallation Venting Outside Through the Roof Measure and mark the lines as shown Use a saber saw or keyhole saw to cut a round opening for the vent en 15 9 cm Centerline Venting Outside Through the Wall Assemble the vent that you will use over the vent opening Do not attach the vent at this time Measure from the top of the screen housing to the horizontal centerline of the vent opening A Remove the vent A Measurement Transfer measurement to the cabinet back wall Measure from the underside of the cabinet or wood filler strips if used Mark the cutout as shown Use a saber saw or keyhole saw to cut a round opening for the vent A Measurement B Centerline C 6 15 9 cm round cutout Change Hood to Optional Rear Exhaust The hood comes from the factory with the exhaust collar on top of the hood The hood exhaust may be directed out the rear of the hood through the exhaust collar A Rear exhaust If you desire to have the hood exhaust out the rear follow the procedure below a Place the range hood on its back b Remove metal filters See Range Hood Care section Cut wire tie from wire bundle d Set the range hood back up to the upright position e Hold the blower motor to keep it from dropping while removing the 4 screws holding the exhaust bl
54. staller des tringles d appui en bois d une longueur minimale de 5 12 7 cm contre le plancher du placard La bride de montage peut tre r gl e entre 56 15 9 mm 278 54 mm pour la prise en compte des tringles d appui en bois A B A Moins de 34 15 9 mm B Tringles d appui en bois paisseur en fonction des exigences Les brides ressort sont install es l usine afin de convenir une paisseur allant de 13 2 3 0 cm 24 5 7 cm Si l paisseur du fond du placard est inf rieure 1 6 3 0 cm les brides ressort peuvent tre retir es et repositionn es plus bas du r glage sup rieur A vers le r glage inf rieur B en retirant les 4 vis Phillips A A B O B A A B O B A R glage sup rieur install l usine B R glage inf rieur Placer le clapet circulaire dans l ouverture d vacuation de la hotte et exercer une pression vers le bas Si la bouche de d charge travers le toit ou la bouche de d charge murale comporte un clapet ne pas fixer le clapet la hotte d vacuation A Clapet anti reflux B l ment coulissant de la hotte de cuisini re Placer la hotte en appui sur la face arri re sur une surface prot g e a Faire glisser l l ment coulissant de la hotte vers l avant b ter les filtres graisse m talliques Voir la section Entretien de la hotte 27 11 Visser les brides de montage la position sup
55. t cover included with the range hood or other vent cover as a template to outline an opening for the vent Use a saber saw or keyhole saw to cut a round opening for the vent System The range hood can be vented inside through the top of the cabinet Centerline For non vented recirculating installations charcoal filters are necessary See the Range Hood Care section for instructions on installing charcoal filters The Recirculation Kit Part Number 4396565 must be used Install the vent system according to the method needed Use caulking to seal the exterior wall or roof opening Run the wiring through the wall or cabinet according to the national Electrical Code and all local codes and ordinances Use caulking to seal around wire opening 7 Measure the thickness of the cabinet floor including the filler strips if used If the thickness is less than 34 15 9 mm install wood filler strips that are a minimum length of 5 12 7 cm onto the cabinet floor The mounting bracket adjusts from 9 15 9 mm to 278 54 0 mm for the wood filler strips A A Less than 9 15 9 mm B Wood fillers thickness as required 8 The spring loaded brackets are factory set to accommodate a thickness between 1 6 3 0 cm and 274 5 7 cm If your cabinet bottom is less than 13 2 3 0 cm thick the spring loaded brackets can be removed and repositioned down from the top setting A to the bottom se
56. t r alis e avant celle de la hotte m Avant de proc der aux d coupages v rifier que les distances de s paration pour les raccords dans les cavit s du plafond ou du mur sont ad quates 1 D connecter la source de courant lectrique D terminer la m thode d vacuation utiliser d charge travers le mur ou le toit ou recyclage 3 S lectionner une surface plane pour l assemblage de la hotte Placer le mat riau de protection sur cette surface AVERTISSEMENT Risque du poids excessif Utiliser deux ou plus de personnes pour d placer et installer la hotte de la cuisini re Le non respect de cette instruction peut causer une blessure au dos ou d autre blessure 4 l aide de deux personnes ou plus soulever la hotte et la poser sur la surface couverte 24 Ouverture d coup e du placard pour la hotte Rep rer et tracer clairement l axe central sur la face inf rieure du placard Axe central 2 Relever les mesures appropri es et tracer les lignes indiqu es sur l illustration selon la taille de la hotte Utiliser une scie sauteuse ou scie guichet pour d couper l ouverture travers le fond du placard 198 3 5 cm N X Tu cm m X m hotte de 30 76 2 cm 1258 32 0 cm hotte de 36 91 4 cm 15 39 7 cm Dimensions de l ouverture finie Hotte de 30 76 2 cm 91 6 x 2574 24 9 cm x 64 1 cm H
57. tting B by removing the 4 Phillips screws A A B B A A B O O B A Top setting factory installed B Bottom setting 9 Place the round damper into the vent opening of the range hood and press down If the roof cap or wall cap has a damper do not attach the damper to the range hood A Damper B Range hood screen 10 Place the range hood on its back side on a covered surface a Slide the range hood screen forward b Remove the metal grease filters See Range Hood Care section 11 Screw the mounting brackets up to the top position A Mounting bracket screw B Flat blade screwdriver NOTE For some non vented recirculating installations it may be easier to attach the vent system to the range hood before lifting the range hood into its final location Seal the connection with clamps AWARNING Excessive Weight Hazard Use two or more people to move and install range hood Failure to do so can result in back or other injury 1 Using 2 or more people lift the range hood into its final position The wiring and terminal box are to be on top of the range hood 2 Check that the mounting brackets overlap the cabinet bottom or wood filler strips 3 Center the range hood A Mounting bracket B Optional wood filler strip Cabinet bottom D Optional wood filler strip for recessed cabinet E Slide out range hood 11 4 Check that the front p
58. uement Commander la pi ce num ro 4396565 Filtres au charbon de rechange pour installations sans d charge l ext rieur uniquement Commander la pi ce num ro 4378623 GARANTIE DU SYSTEME DE VENTILATION KITCHENAID GARANTIE LIMIT E Pendant un an compter de la date d achat lorsque ce gros appareil m nager est utilis et entretenu conform ment aux instructions jointes ou fournies avec le produit la marque KitchenAid de Whirlpool Corporation ou Whirlpool Canada LP ci apr s d sign es KitchenAid paiera pour les pi ces sp cifi es par l usine et la main d uvre pour corriger les vices de mat riaux ou de fabrication Le service doit tre fourni par une compagnie de service d sign e par KitchenAid Cette garantie limit e est valide uniquement aux tats Unis ou au Canada et s applique exclusivement lorsque appareil est utilis dans le pays il a t achet A l ext rieur du Canada et des 50 tats des tats Unis cette garantie limit e ne s applique pas Une preuve de la date d achat original est exig e pour obtenir un service dans le cadre de la pr sente garantie limit e ARTICLES EXCLUS DE LA GARANTIE La pr sente garantie limit e ne couvre pas 1 Les visites de service pour rectifier l installation du gros appareil m nager montrer l utilisateur comment utiliser l appareil remplacer ou r parer des fusibles ou rectifier le c blage ou la plomberie du domicile 2 Les visites de servi
59. umber in your correspondence Call the KitchenAid Canada Customer eXperience Centre toll free 1 800 807 6777 Our consultants provide assistance with m Features and specifications on our full line of appliances m Use and maintenance procedures m Accessory and repair parts sales Referrals to local dealers repair parts distributors and service companies KitchenAid Canada designated service technicians are trained to fulfill the product warranty and provide after warranty service anywhere in Canada For further assistance If you need further assistance you can write to KitchenAid Canada with any questions or concerns at Customer eXperience Centre KitchenAid Canada 200 6750 Century Ave Mississauga Ontario L5N 0B7 Please include a daytime phone number in your correspondence Recirculation Kit for non vented installations only Order Part Number 4396565 Replacement Charcoal Filters for non vented installations only Order Part Number 4378623 17 KITCHENAID VENTILATION WARRANTY LIMITED WARRANTY For one year from the date of purchase when this major appliance is operated and maintained according to instructions attached to or furnished with the product KitchenAid brand of Whirlpool Corporation or Whirlpool Canada LP hereafter KitchenAid will pay for Factory Specified Parts and repair labor to correct defects in materials or workmanship Service must be provided by a KitchenAid designated s
60. utes apr s une cuisson afin d vacuer toute odeur de cuisson et fum e de la cuisine Commande du ventilateur Qa on Fonctionnement du ventilateur 1 Faire glisser l l ment coulissant de la hotte vers l avant REMARQUE Lorsque l l ment coulissant est ouvert le ventilateur fonctionne au r glage auquel le commutateur tait plac lorsque l l ment coulissant a t ferm Le ventilateur s arr te lorsque l l ment coulissant se trouve environ 2 5 1 cm de la position de fermeture 2 Pour mettre le ventilateur en route placer le commutateur du ventilateur 0 arr t la vitesse de ventilateur souhait e savoir 1 basse 2 moyenne ou 3 lev e REMARQUE tout moment durant le fonctionnement de la hotte on peut augmenter ou diminuer la vitesse du ventilateur de la hotte ou encore arr ter le ventilateur 3 Pour teindre le ventilateur placer le commutateur de ventilateur 0 arr t ou fermer l l ment coulissant REMARQUE Le ventilateur s teint lorsque l l ment coulissant se trouve environ 2 5 1 cm de sa position de fermeture Lorsque l l ment coulissant est ouvert le ventilateur fonctionne la vitesse correspondant au dernier r glage Commande d clairage Fonctionnement de l clairage 1 Ouvrir l l ment coulissant de la hotte 2 Pour allumer la lumi re d placer l interrupteur de 0 arr t 1 marc
Download Pdf Manuals
Related Search
Related Contents
Marais de la vallée des Baux et marais - Pôle ارشادات االستعامل قسطرة مبحلول مايئ لإلستعامل ملرة واحدة Double-DIN Kit Installation Manual Compatible with these 製 品 安 全 デ ー タ シ ー ト ( M S D S ) - O TR125 PollEx PCB_Eng OWNER`S MANUAL - Victor Technologies Magento Troubleshooting Inhaltsverzeichnis - RM-Business TMPO Copyright © All rights reserved.