Home

KitchenAid KSBN220 User's Manual

image

Contents

1. Installation Instructions and Use and Care Guide Outdoor Built In Side Burner Model KSBN220 Quick Reference Table of Contents Pages 2 3 Before you start 4 Product dimensions 4 Cutout dimensions IMPORTANT 5 Gas supply requirements Read and save these instructions 6 Installation steps 6 Checking adjusting burners IMPORTANT Installer Leave Installation Instructions with the consumer 7 8 Use and Care Information Homeowner Keep Installation Instructions for future reference 9 Warranty Save Installation Instructions for local electrical inspector s use 10 11 Requesting Assistance or Service Write the model and serial numbers in space provided below before installing or using outdoor Side Burner The numbers are stamped on the identification label located on bottom flange of the control panel they are also located on the model serial number plate located on the side panel a a KitchenAid Hi fodar FOR THE WAY IT S MADE Serial Part No 8190046 Before you start Your safety and the safety of others are very important We have provided many important safety messages in this manual and on your appliance Always read and obey all safety messages This is the safety alert rN symbol This symbol alerts you to potential hazards that can kill or hurt you and others All safety messages will follow
2. see Gas Supply Requirements e Using an L P propane gas cylinder Slowly open the cylinder valve do not snap open NOTE When using an L P gas cylinder the flow limiting device may activate and your side burner may not light If your side burner does light the flames will be low and will not heat properly Turn cylinder valve and all control knobs off and wait 30 seconds After shutting off the cylinder very slowly open cylinder valve and wait 5 seconds before lighting Lighting the side burner IMPORTANT Light only one burner at a time 1 Do not lean over burners Push in and turn to LITE the control knob for the burner you wish to use igniter button front rear burner burner 2 Push in the burner ignitor button You will hear the snapping sound of the spark Keep the burner ignitor button pushed in until burner lights Make sure burner is lit Repeat for the other burner as needed IMPORTANT If burner does not light immediately turn the burner knob to OFF and wait 5 minutes before relighting Manually lighting the burners 1 Strike a match to light it 2 Carefully guide the lit match to the burner you wish to light 3 Push in and turn the burner knob to LITE for the burner closest to the lit match The burner will light immediately 4 Repeat steps 1 through 3 for each burner IMPORTANT If burner does not light immediately turn the burner knob
3. service Boutons mati re plastique et rebord de l appareil autour des boutons IMPORTANT Ne pas utiliser de laine d acier produit de nettoyage abrasif ou produit de nettoyage de four Ne pas faire tremper les boutons e Laver avec un d tergent doux et de l eau ti de avec un chiffon doux Rincer et faire s cher El ments graphiques du panneau de commande IMPORTANT Ne pas utiliser de laine d acier produit de nettoyage abrasif ou produit de nettoyage de four Ne pas pulv riser le produit de nettoyage directement sur le panneau Nettoyer d licatement autour des tiquettes des brdleurs le lavage peut effacer les l ments imprim s e Laver avec un d tergent doux et de l eau ti de avec un chiffon doux Rincer et faire s cher Garantie Brdleur lat ral gaz KitchenAid Garantie DUR E DE LA GARANTIE GARANTIE TOTALE D UNE ANN E compter de la date d achat Garantie limit e de cinq ans De la seconde la cinqui me ann e ann e inclusivement compter de la date d achat pi ces seulement KitchenAid PAIERA POUR Pi ces sp cifi es par l usine et main d ceuvre d intervention pour limination des vices de mat riau OU de fabrication Le travail doit tre ex cut par une entreprise de service apr s vente agr e par KitchenAid Pendant cing ans a compter de la date d achat lorsque le brdleur lat ral est utilis conform ment aux instructions fourni
4. Enfoncer faire tourner le bouton de commande du br leur choisi jusqu la position du d bit thermique minimum LITE foe 2 Appuyer sur le bouton d alumage du br leur On doit percevoir le bruit de d clic du module d tincelage Maintenir le bouton d allumage du br leur enfonc jusqu ce que le br leur soit allum V rifier la pr sence des flammes sur le br leur R p ter pour chacun des autres br leurs selon le besoin IMPORTANT Si un br leur ne eut s allumer en 5 secondes fermer le robinet de ce br leur et attnedre 5 minutes avant une autre tentative bouton d allumage br leur br leur avant arri re Allumage manuel des br leurs 1 Frotter l allumette pour l allumer 2 Guider soigneusement l allumette allum e au br leur que vous souhaitez allumer 3 Enfoncer le bouton du br leur le plus proche de l allumette et le tourner LITE Le br leur s allumera imm diatement 4 R p ter les tapes 1 a 3 inclusivement pour chaque br leur principal IMPORTANT Si le br leur ne s allume pas imm diatement tourner le bouton du br leur OFF et attendre 5 minutes avant de le rallumer Si certains br leurs ne s allument pas apr s une tentative d allumage manuel contacter le Centre d assistance KitchenAid Voir la section Demande d assistance ou de service Remplacement de la pile de l allumeur Si un allumeur ne produ
5. Veuillez indiquer dans votre correspondance un num ro de t l phone o l on peut vous joindre dans la journ e 11 Article n 8190046 2003 KitchenAid Marque d pos e Marque de commerce de KitchenAid U S A KitchenAid Canada porteur de licence au Canada KitchenAid HOME APPLIANCES Pr par par KitchenAid Benton Harbor Michigan 49022 Imprim aux E U
6. Year from accordance with instructions attached or furnished with product KitchenAid will pay for Date of Purchase parts only Factory Specified Parts to correct defects in materials or workmanship KitchenAid also warrants that the structural integrity of the gas side burner is free from defects in materials or workmanship under normal recommended use for a period of five years from the date of purchase Limited Lifetime Warranty KitchenAid warrants that the stainless steel body housings will be free from defects On all Stainless Steel components in material and workmanship when subjected to normal domestic use and service for the lifetime of the appliance This warranty excludes damage to the finish such as scratches or discoloration which may occur during regular use The above warranty is limited to the replacement costs of the above component parts KitchenAid WILL NOT PAY FOR Installation of your gas side burner or damage caused by improper installation or failure to comply with local code requirements Shipping pickup and delivery removal or re installation as your gas side burner is designed to be repaired in the home Service calls to 1 Correct the installation of your KitchenAid gas side burner 2 Instruct you how to use your KitchenAid gas side burner 3 Replace house fuses or correct house wiring 4 Perform normal maintenance including periodic replacement of seals fittings etc Conversion kit or
7. bouteille de propane Voir la section Instructions d installation 13 Lorsque le gril pour ext rieur n est pas utilis fermer le robinet de la bouteille de gaz 14 Le remisage du br leur lat ral pour ext rieur n est permis que si la bouteille de gaz a t d connect e et s par e du br leur lat ral pour ext rieur 15 Une bouteille de gaz doit tre remis e l ext rieur hors d atteinte des enfants on ne doit jamais remiser une bouteille de gaz dans un b timent ou garage ou dans un local ferm 16 On doit utiliser le d tendeur et le tuyau de raccordement fournis avec le br leur lat ral pour ext rieur Le d tendeur et le tuyau de raccordement sp cifi s pour le mod le achet sont identifi s la section Instructions d installation 17 La configuration du syst me d alimentation par une bouteille de gaz doit permettre l extraction ad quate du produit gazeux 18 La bouteille de gaz doit inclure un chapeau de protection du robinet AVERTISSEMENT Si les instructions de ce manuel ne sont pas scrupuleusement respect es il pourrait se produire un incendie ou une explosion susceptibles de provoquer des dommages mat riels ou corporels voire un d c s Si les directives suivantes ne sont pas scrupuleusement observ es il peut se produire un incendie qui susciterait des dommages corporels graves ou mortels e Ne pas remiser une bouteille de gaz sous le br leur lat ral
8. burner 1 2 side burner gas pipe Ie ij 16 y flexible gas ___ connector e If local codes permit use a flexible stainless steel tubing gas connector design certified and marked outdoor by AGA or CSA International to connect the side burner to the rigid gas supply line 5 8 diameter line is recommended Using a wrench to tighten connect the gas supply to the side burner Use pipe joint compound on all non flared male threads Do not kink or damage the flexible connector when moving the side burner e Pipe joint compounds suitable for use with L P gas must be used Do not use Teflon tape valve open oe valve closed 3 m Open shutoff valve in the gas supply line The valve is open when the handle is parallel to the gas pipe 4 m Test all connections by brushing on an approved non corrosive leak detection solution Bubbles will show a leak Correct any leak found 5 m Carefully lift off cover and grate and set aside Remove packing from around burners Reinstall grate 6 m Carefully move Side Burner completely into enclosure T m Go to Checking and adjusting the burners Checking and adjusting the burners The burners are tested and factory set for most efficient operation However variations in gas supply and other conditions may make minor adjustments to low flame setting necessary Adjustments must be done by a qualified service technician Checking and adjusting the burner
9. clearance dimensions that are shown must be used Given dimensions provide required clearances The installation of this Side Burner must conform with the current standards CSA Z21 58a 1998 or with local codes The side burner drops into the enclosure opening and is supported by its side flanges No bottom support is needed Copies of the standards listed may be obtained from CSA International 8501 East Pleasant Valley Rd Cleveland Ohio 44131 5575 Tools and parts 26 66 0 cm 25 1 2 64 8 cm 1 2 male NPT lt lt 21 3 8 54 3 cm gt 3 1 2 8 9 cm 12 30 5 cm minimum to grill or any accessor 1 8 PR RAE he Bae Le gas line location at rear of side burner 35 1 2 27 0 cm 90 2 cm counter or support surfaces must be level Tools needed Parts needed Parts supplied level e gas line shutoff valve e convertible regulator set for 4 W C natural e small flat blade screwdriver e 1 2 male pipe thread nipple for connection gas flat blade screwdriver to pressure regulator e Phillips screwdriver e L P gas resistant pipe joint compound e tape measure or ruler AGA or CSA design certified outdoor e slip joint pliers flexible stainless steel appliance connector pipe wrench 4 5 ft 1 2 1 5 m or rigid gas supply line as needed e non corrosive leak detection solution Location requirements Select a location that provides minimum exposure
10. flames requires removing the grate valve stem Low flame adjustment If flame goes out on the LO setting the low flame setting must be adjusted Light the burner and turn control knob to its lowest setting and remove knob Hold the valve stem with pliers and insert a thin flat blade screwdriver into the shaft Watch the flame and slowly turn screwdriver counterclockwise Adjust flame to the minimum stable flame Replace control knob Reassemble grate Copies of the standards listed may be obtained from CSA International 8501 East Pleasant Valley Rd Cleveland Ohio 44131 5575 for local codes contact your local building inspector Teflon is a registered trademark of E I Du Pont de Nemours and Company Use and Care of your Side Burner Using your Side Burner WARNING A ies Burn Hazard Do not let the burner flame extend beyond the edge of the pan Doing so can result in burns A WARNING Food Poisoning Hazard Do not let food sit for more than one hour before or after cooking Doing so can result in food poisoning or sickness 1 Remove side burner cover Do not light burners with the cover on 2 Make sure control knobs are turned to OFF 3 Turn the gas supply on Natural gas or L P gas from a local supply e Using gas supply source other than L P gas cylinder Turn the shutoff valve to open position from the front of gas supply line L P gas cylinder if converted
11. flammes sur le br leur n cessitent la d pose de la grille tige du robinet R glage de la puissance de chauffage minimale Si les flammes d un br leur s teignent alors qu il est r gl pour la puissance de chauffage minimale on doit effectuer un r glage Allumer le br leur et tourner le bouton de commande la position correspondant la puissance de chauffage minimale et ter le bouton Immobiliser la tige du robinet avec une pince et ins rer un tournevis lame plate mince dans la tige creuse Observer les flammes faire tourner lentement le tournevis dans le sens inverse des aiguilles d une montre Trouver la position qui permet le maintien des plus petites flammes stables R installer le bouton de commande R installer la grille On peut se procurer un exemplaire des normes mentionn es l adresse suivante CSA International 8501 East Pleasant Valley Rd Cleveland Ohio 44131 5575 au sujet des codes locaux contacter l inspecteur local des b timents Teflon est une marque de commerce d pos e de E I Du Pont de Nemours and Company Utilisation et entretien 29 ble te du br leur lat ral Utilisation du br leur lat ral AVERTISSEMENT RAT rr Ted Risque de br lure Ne pas laisser la flamme du br leur d passer le bord de la po le Le non respect de cette instruction peut causer des br lures AVERTISSEMENT Risque d empoisonnement alime
12. of the installer to comply with the minimum installation clearances specified on the model serial rating plate The model serial rating plate can be found on the side panel Copies of the standards listed may be obtained from National Fire Protection Association One Batterymarch Park Quincy Massachusetts 02269 CSA International 8501 East Pleasant Valley Rd Cleveland Ohio 44131 5575 The California Safe Drinking Water and Toxic Enforcement Act requires the Governor of California to publish a list of substances known to the State of California to cause cancer birth defects or other reproductive harm and requires businesses to warn of potential exposure to such substances WARNING This product contains a chemical known to the State of California to cause cancer birth defects or other reproductive harm This appliance can cause low level exposure to some of the substances listed including benzene crystalline silica carbon monoxide toluene and soot In the State of Massachusetts the following installation instructions apply e Installations and repairs must be performed by a qualified or licensed contractor plumber or gasfitter qualified or licensed by the State of Massachusetts e If using a ball valve it shall be a T handle type e A flexible gas connector when used must not exceed 3 feet Product E Dimensions 13 1 4 33 7 cm Enclosure Cutout Dimensions Enclosure and
13. ou proximit e Ne jamais remplir une bouteille de gaz plus de 80 Important Ce br leur lat ral est fabriqu pour une utilisation l ext rieur seulement Pour les br leurs lat raux utilis s une altitude sup rieure 2000 pieds on doit remplacer le gicleur d admission de gaz Voir la section Alimentation en gaz Sp cifications C est l installateur qu incombe la responsabilit du respect des distances de s paration minimales sp cifi es sur la plaque signal tique On trouve la plaque signal tique sur le panneau lat ral On peut se procurer un exemplaire des normes mentionn es aux adresses suivantes National Fire Protection Association One Batterymarch Park Quincy Massachusetts 02269 CSA International 8501 East Pleasant Valley Rd Cleveland Ohio 44131 5575 La loi californienne Safe Drinking Water and Toxic Enforcement Act oblige le Gouverneur de la Californie a publier une liste des substances qui a la connaissance de l Etat de la Californie causent le cancer des d fauts cong nitaux ou sont autrement nuisibles la reproduction et elle oblige aussi les entreprises mettre en garde contre l exposition potentielle de telles substances AVERTISSEMENT Ce produit contient un produit chimique qui la connaissance de l Etat de la Californie cause le cancer des d fauts cong nitaux ou est autrement nuisible la reproduction Cet appareil peut causer une
14. ou utiliser de l essence ou un autre produit liquide ou gazeux inflammable a proximit de cet appareil ou de tout autre appareil m nager e Une bouteille de propane qui n est pas connect e pour l utilisation ne doit pas tre remis e proximit de cet appareil ou de tout autre appareil m nager INSTRUCTIONS DE S CURIT IMPORTANTES Ne pas installer les br leurs lat raux dans un v hicule r cr atif une remorque un bateau ou autre quipement mobile Veiller toujours respecter les distances de s paration minimales entre l appareil et les mati res combustibles voir la section Emplacement d installation L appareil de cuisson gaz pour ext rieur ne doit pas tre install au dessous d une construction en mat riaux combustibles Cet appareil de cuisson gaz pour ext rieur ne doit tre utilis qu l ext rieur et ne doit pas tre utilis dans un b timent un garage ou tout autre espace ferm Veiller ne pas approcher le cordon d alimentation lectrique et les canalisations de combustible des surfaces chaudes Veiller ne jamais avoir de mati re combustible essence ou autre produit inflammable liquide ou gazeux proximit de l appareil de cuisson gaz pour ext rieur 7 Ne pas entraver la circulation d air de combustion et de ventilation Veiller ce que les ouvertures de ventilation du logement de la bouteille de gaz ne soien
15. service call for the conversion of your gas side burner from natural gas to LP propane or from LP propane to natural gas Repairs when your gas side burner is used in other than normal single family household use Damage to your gas side burner caused by negligence accident misuse fire flood acts of God or use of products including cleaning products not approved by KitchenAid or KitchenAid Canada Repairs to parts or system resulting from unauthorized modifications to your gas side burner In Canada travel or transportation expenses for customers who reside in remote areas Replacement parts or repair labor costs for units operated outside the United States and Canada Any labor costs during limited warranty period Deterioration due to normal wear and tear of your gas side burner Notice Regarding All KitchenAid gas side burner installations Access must be provided to the side burner s gas source Install and operate each gas side burner according to instructions provided with product KitchenAid and KitchenAid Canada Shall Not be Liable for Incidental or Consequential Damages Any implied warranty or merchantability or fitness for a particular purpose is limited in duration to the duration of this warranty Some states do not allow the exclusion or limitation of incidental or consequential damages or allow limitations on how long an implied warranty lasts so these exclusions or limitations may not apply to you This war
16. sur le module d installation laisser suffisamment d espace l arri re pour pouvoir raccorder l appareil la source de gaz A AVERTISSEMENT Risque d explosion Utiliser une canalisation de gaz neuve agr ment AGA ou CSA pour l ext rieur Bien serrer toutes les connexions de la canalisation de gaz Si le br leur gaz est aliment au propane demander une personne qualifi e de v rifier que la pression du gaz ne d passe pas 28 cm 11 po colonne d eau Exemples de personnes qualifi es chauffagiste professionnel personnel autoris d un fournisseur de gaz et technicien d entretien agr Le non respect de ces instructions peut causer un d c s une explosion ou un incendie 2 m R aliser toutes les connexions du circuit de gaz Il faut utiliser diff rents raccords pour la connexion du gril a la canalisation de gaz existante 6 arri re du br leur canalisation de gaz du lat ral br leur lat ral de 1 2 po raccord de ___ gaz flexible Si les codes locaux le permettent utiliser un tuyau en acier inoxydable flexible homologu par l AGA ou CSA International pour raccorder le br leur lat ral la canalisation de gaz rigide Une canalisation de 5 8 po de diam tre est recommand e Connecter l alimentation de gaz au br leur lat ral et serrer les raccords avec une cl Utiliser un compos d tanch it des jointures sur tous les filetages m
17. the safety alert symbol and either the word DANGER or WARNING These words mean ADANGER You can be killed or seriously injured if you don t immediately follow instructions WARNING You can be killed or seriously injured if you don t follow instructions All safety messages will tell you what the potential hazard is tell you how to reduce the chance of injury and tell you what can happen if the instructions are not followed FOR YOUR SAFETY IF YOU SMELL GAS e Shut off gas to the appliance e Extinguish any open flame e Open lid e If odor continues immediately call your gas supplier or your fire department FOR YOUR SAFETY e Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliances e An LP cylinder not connected for use shall not be stored in the vicinity of this or any other appliance IMPORTANT SAFETY INSTRUCTIONS Do not install outdoor cooking appliance in or on a recreational vehicle portable trailer boat or in any other moving installation Always maintain minimum clearances from combustible construction see Location requirements section 3 The outdoor cooking gas appliance shall not be located under overhead combustible construction 4 This outdoor cooking gas appliance shall be used only outdoors and shall not be used in a building garage or any other enclosed area Keep any ele
18. P gas cylinder not larger than 20 pounds must be purchased separately NATURAL GAS Set pressure 4 inches 10 2 cm W C Supply pressure 7 14 inches 17 8 cm to 35 5 cm W C maximum L P GAS Operating pressure 11 inches 28 cm W C Supply pressure 11 to 14 inches 28 to 35 5 cm W C Side Burner Installation WARNING Excessive Weight Hazard Use two or more people to move and install side burner Failure to do so can result in back or other injury Natural Gas This installation must conform with local codes and ordinances In the absence of local codes installations must conform with either the National Fuel Gas Code ANSI 2223 1 or CAN CGA B149 1 Natural Gas and Propane installation code 1 m Place side burner into outdoor enclosure but leave enough room in back to connect to gas supply A WARNING Explosion Hazard Use a new AGA or CSA approved outdoor gas supply line Securely tighten all gas connections If connected to LP have a qualified person make sure gas pressure does not exceed 11 28 cm water column Examples of a qualified person inclued licensed heating personnel authorized gas company personnel and authorized service personnel Failure to do so can result in death explosion or fire 2 m Make gas connections A combination of pipe fittings must be used to connect the side burner to the existing gas line 6 rear of side
19. act the dealer from whom you purchased your appliance or call toll free 1 800 422 1230 2 If you need servicet Contact your nearest KitchenAid Canada Appli ance Service branch or authorized servicing outlet to service your appliance See list below Make sure the service company you contact is authorized to service your appliance during the warranty period TWhen asking for assistance or service please provide a detailed description of the problem your appliance s complete model and serial numbers and the purchase date This information will help us respond properly to your request KitchenAid Canada Appliance Service Consumer Services Direct service branches BRITISH COLUMBIA 1 800 665 6788 ALBERTA 1 800 661 6291 ONTARIO except 807 area code 1 800 267 3456 1 800 807 6777 Ottawa area Outside the Ottawa area MANITOBA SASKATCHEWAN and 807 area code in ONTARIO 1 800 665 1683 QUEBEC 1 800 361 3032 1 800 361 0950 1 800 463 1523 1 800 567 6966 Montreal except South Shore South Shore Montreal Quebec City Sherbrooke ATLANTIC PROVINCES For further assistance If you need further assistance you can write to KitchenAid Canada with any questions or concerns at Consumer Relations Department KitchenAid Canada 1901 Minnesota Court Mississauga Ontario L5N 3A7 1 800 565 1598 Please include a daytime phone number in your correspondence 11 P
20. art No 8190046 2003 KitchenAid Registered Trademark Trademark of KitchenAid U S A KitchenAid Canada licensee in Canada KitchenAid HOME APPLIANCES Prepared by KitchenAid Benton Harbor Michigan 49022 Printed in U S A Instructions d installation et Guide d utilisation et d entretien Br leur lat ral encastr pour ext rieur SS oo 3 Mod le KSBN220 Consultation rapide Table des mati res Pages 2 3 Avant de commencer IMPORTANT 4 Dimensions du produit Lire et conserver ces instructions 4 Dimensions pour l installation du produit 5 Alimentation en gaz Sp cifications IMPORTANT 6 tapes de l installation Installateur Remettre les instructions d installation au propri taire fe Contr le r glage des br leurs Propri taire Conserver les instructions d installation pour 7 g Utilisation et entretien consultation ult rieure Conserver les instructions d installation pour consultation par 9 Garantie l inspecteur local des installations lectriques 10 11 Demande d assistance ou de service Avant d installer ou d utiliser le br leur lat ral pour ext rieur inscrire ci dessous le num ro de mod le et le num ro de s rie On trouve ces num ros sur l tiquette d identification situ e sur le rebord inf rieur du tableau de commande Ceci est galement signal sur la plaque signal tique
21. ctrical supply cord and fuel supply hose away from any heated surfaces Keep outdoor cooking and appliance area clear and free from combustible materials gasoline and other flammable vapors and liquids Do not obstruct the flow of combustion and ventilation air Keep the ventilation openings of the cylinder enclosure free and clear from debris Inspect the gas cylinder supply hose before each use of the side burner If the hose shows excessive abrasion or wear or is cut it MUST be replaced before using the side burner Contact your dealer and use only replacement hoses specified for use with the side burner Visually check the burner flames They should be blue Slight yellow tipping is normal for L P gas 10 Check and clean burner venturi tube for insects and insect nest A clogged tube can lead to fire under the side burner 11 The L P gas supply cylinder to be used must be e constructed and marked in accordance with the Specification for L P Gas Cylinders of the U S Department of Transportation DOT or the National Standard of Canada CAN CSA B339 Cylinders Spheres and Tubes for Transportation of Dangerous Goods and Commission e provided with a listed overfilling prevention device e provided with a cylinder connection device compatible with the connection for outdoor side burner appliances Always check connections for leaks each time you connect and disconnect the L P gas supply cy
22. de gaz une pression gale ou inf rieure 1 2 Ib po 3 5 kPa on doit fermer le robinet d arr t individuel pour isoler le br leur lat ral de la canalisation d arriv e de gaz Br leurs lat raux encastr s Gaz naturel Les mod les de br leurs lat raux sont configur s pour l alimentation au gaz naturel Leur conception est homologu e par CSA International pour l alimentation au propane ou butane apr s conversion appropri e Le br leurs lat raux sont r gl s pour l utilisation au gaz naturel le d tendeur pour gaz naturel comporte un filetage femelle de 1 2 po robinet d arr t position d ouverture vers le _ br leur lat ral canalisation d arriv e de gaz La canalisation d arriv e de gaz doit tre dot e d un robinet d arr t homologu Ce robinet devrait tre au voisinage du br leur lat ral un endroit o on peut y acc der facilement pour les man uvres d ouverture et de fermeture Ne pas entraver l acc s au robinet d arr t Le robinet permet d ouvrir ou de fermer l alimentation en gaz de l appareil Conversion au gaz propane Conversion pour l alimentation au propane depuis une source locale de propane L op ration de conversion doit tre ex cut e par un technicien qualifi Un technicien qualifi pour le gaz naturel doit installer une canalisation de propane jusqu au point d installation du br leur lat ral en conformit avec les prescrip
23. e ou de service aux E U Composez le num ro sans frais 1 800 422 1230 Nos consultants sont pr ts vous aider CS Nos consultants vous renseigneront sur les sujets suivants Lors d un appel veuillez conna tre la date d achat et les num ros complets de mod le et de s rie de votre appareil Ces renseignements nous aideront mieux r pondre votre demande e Caract ristiques et sp cifications de notre gamme compl te d appareils lectrom nagers e Renseignements sur l installation e M thodes d utilisation et d entretien e Vente de pi ces de rechange et d accessoires e Assistance sp cialis e la client le langue espagnole malentendants malvoyants etc e Coordonn es des revendeurs compagnies de service et distributeurs locaux de pi ces de rechange Les techniciens de service d sign s par KitchenAid ont re u une formation qui leur permet d effectuer les travaux de r paration sous garantie et le service apr s garantie partout aux Etats Unis Vous pouvez galement consulter les Pages jaunes de l annuaire t l phonique pour identifier une compagnie de service agr e KitchenAid dans votre r gion Si vous avez besoin de pieces de rechange Si vous devez commander des pi ces de rechange nous vous recommandons d utiliser seulement les pi ces de rechange d origine Ces pi ces de rechange conviendront et fonctionneront bien parce qu elles sont fabriqu es selon les m mes sp cification
24. es avec le produit KitchenAid paiera le co t des pi ces sp cifi es par lusine pour l limination des vices de mat riaux et de fabrication KitchenAid garantit galement qu aucun vice de mat riau ou de fabrication n affecte l int grit structurale du br leur lat ral gaz utilis dans les conditions normales recommand es pendant une p rode de cinq ans compter de la date d achat Garantie limit e vie sur tous les composants en acier inoxydable KitchenAid garantit que le car nage d acier inoxydable du gril utilis dans les conditions normales d utilisation familiale est exempt de vice de mat riau ou de fabrication pendant toute la dur e de vie utile de l appareil Ceci ne couvre pas les d t riorations de la finition comme raflures ou changement de couleur qui peuvent survenir dans le cadre de l utilisation r guli re La garantie ci dessus ne couvre que le co t de remplacement des composants cit s ci dessous KitchenAid NE PAIERA PAS POUR Installation du br leur lat ral ou r paration de dommages imputables une installation incorrecte ou au non respect des exigences du code local Exp dition livraison d pose et r installation du br leur lat ral le br leur lat ral est con u pour tre r par sur place Intervention pour 1 Correction de l installation du br leur lat ral gaz KitchenAid 2 Instruction de l utilisateur pour l utilisation du br leur lat ral
25. evis Phillips e m tre ruban ou r gle pince multiprise articulation mobile e cl tuyauterie LE 33 7 cm 13 1 4 po 30 5 cm oe po gt gril ou tout accessoire Pi ces n cessaires e robinet d arr t pour la canalisation de gaz raccord filet m le 1 2 po pour le raccordement au d tendeur e compos d tanch it des jointures r sistant au propane raccord flexible d acier inoxydable homologation AGA ou CSA 4 5 pi 1 2 1 5 m ou canalisation de gaz rigide selon le besoin e solution de d tection des fuites non corrosive s paration de 12 po 30 5 cm ou plus pour le 66 0 cm 26 po 64 8 cm 25 1 2 po raccord m le NPT 2 po 30 8 cm eS 57 2 cm 22 1 2 po passage pour la canalisation de gaz l arri re du br leur lat ral 90 2cm 35 172 po la surface de pose de l appareil doit tre horizontale Pi ces fournies e d tendeur convertible r gl pour une pression de 4 po col d eau pour le gaz naturel Emplacement d installation Choisir un emplacement qui minimise l exposition au vent et la circulation des personnes L emplacement ne devrait pas tre expos de forts courants d air Ne pas entraver l arriv e d air de ventilation ni d vacuation des gaz de combustion Alimentation en gaz Specifications Respecter les prescriptions des codes et r glements en vigueur Important Le br leur la
26. exposition de faible intensit certaines des substances num r es y compris le benz ne la silice cristalline le monoxyde de carbone le tolu ne et la suie Dans l tat du Massachusetts les instructions d installation suivantes s appliquent e Les installations et r parations doivent tre effectu es par un entrepreneur ou plombier qualifi ou agr ou par un monteur d installations au gaz qualifi ou agr par l tat du Massachusetts e Si on utilise un clapet bille il doit tre du type manche en forme de T e Un raccord flexible pour gaz lorsque utilis ne doit pas d passer 3 pieds Dimensions du produit Dimensions pour l installation du produit encastre On doit respecter toutes les dimensions indiqu es pour le module recevant l appareil et pour toutes les distances de s paration L installation de ce br leur lat ral doit satisfaire les prescriptions de la version en vigueur de la norme CSA 721 58a 1998 ou de tout code local applicable Le br leur lat ral s encastre dans l ouverture de l enceinte et est soutenu par ses rebords lat raux Aucun soutien n est n cessaire en bas On peut se procurer un exemplaire des normes mentionn es l adresse suivante CSA International 8501 East Pleasant Valley Rd Cleveland Ohio 44131 5575 Outillage et pieces Outils n cessaires e niveau e petit tournevis lame plate e tournevis lame plate e tourn
27. g Assistance or Service section to order e Use a mild liquid detergent or all purpose cleaner according to label instructions e Rinse with clean water and dry at once with soft lint free cloth to avoid spots and streaks e Use vinegar to remove hard water spots Rinse with water and dry thoroughly e Use a glass cleaner to remove fingerprints IMPORTANT Make sure gas supply is off and all control knobs are in the OFF position Make sure the Side Burner is cool Exterior The quality of this material resists most stains and pitting providing that the surface is kept clean and protected e Apply stainless steel polish to all non cooking areas before first use Re apply after each cleaning to prevent permanent damage to surface e Cleaning should always be followed by rinsing with clean warm water e Wipe the surface completely dry with a soft cloth e For tough spots or baked on grease use Whirlpool Degreaser Part No 31552 a commercial degreaser designed for stainless steel See Requesting Assistance or Service section to order Interior e Cleaning should always be followed by rinsing with clean warm water e Use a mild liquid detergent or all purpose cleaner following label instructions Rinse with clean water and dry completely with a soft lint free cloth e A heavy duty scrub sponge can be used with mild cleaning products Always rub in the direction of the grain e For s
28. gaz KitchenAid 3 Remplacement des fusibles ou modification du c blage lectrique de la r sidence 4 Travaux d entretien de routine ceci incluant le remplacement p riodique de joints raccords etc Ensemble des composants de conversion ou intervention de conversion du br leur lat ral pour changement de combustible gaz naturel propane R parations lorsque le br leur gaz est utilis autrement que dans le cadre du service normal d une r sidence unifamiliale Dommages imputables une n gligence un accident un emploi impropre un incendie une inondation une catastrophe un d sastre naturel ou l utilisation d un produit non approuv par KitchenAid ou KitchenAid Canada R parations sur des composants ou l ensemble imputables a une modification non autoris e du br leur lat ral gaz Au Canada frais de d placement lorsque le client r side en un lieu loign Pi ces de rechange et frais de r paration pour un appareil utilis hors des tats Unis ou du Canada Frais de main d uvre durant la p riode de garantie limit e D t riorations imputables l usure normale du br leur lat ral gaz Avis concernant l installation d un br leur lat ral gaz KitchenAid Un acc s la source de gaz doit tre disponible Installer et utiliser chaque br leur lat ral gaz conform ment aux instructions fournies avec le produit KitchenAid et KitchenAid Canada d clinent toute responsabilit a
29. id appliance help us better respond to your request e Use and maintenance procedures e Accessory and repair parts sales e Specialized customer assistance Spanish speaking hearing impaired limited vision etc e Referrals to local dealers service companies and repair parts distributors KitchenAid designated service technicians are trained to fulfill the product warranty and provide after warranty service anywhere in the United States To locate the designated KitchenAid service company in your area you can also look in your telephone directory Yellow Pages To locate factory authorized parts in your area call 1 800 422 1230 for your nearest authorized service center or KitchenAid Factory Service at 1 800 442 1111 For further assistance If you need further assistance you can write to KitchenAid with any questions or concerns at KitchenAid Brand Home Appliances Customer Interaction Center c o Correspondence Dept 2000 North M 63 Benton Harbor MI 49022 2692 Please include a daytime phone number in your correspondence 10 Requesting Assistance or Service Before calling for assistance or service please check the Use and Care of your Side Burner section It may save you the cost of a service call If you still need help follow the instructions below If you need assistance or service in Canada 1 If the problem is not due to one of the items listed in Check Operation t Cont
30. ind l biles e Utiliser le produit de polissage Stainless Steel Cleaner amp Polish article n 4396095 Pour la commande voir la section Demande d assistance ou de service e Utiliser un d tergent liquide doux ou un produit de nettoyage polyvalent en suivant les instructions fournies avec le produit e Rincer avec de l eau propre puis s cher imm diatement avec un linge doux non pelucheux pour viter de laisser des marques et des taches e Utiliser du vinaigre pour liminer les taches laiss es par de l eau dure Rincer avec de l eau et bien s cher e Utiliser un produit de nettoyage du verre pour liminer les traces de doigt IMPORTANT S assurer que l alimentation en gaz est ferm e et que tous les boutons de commande sont la position OFF arr t S assurer que le br leur lat ral est froid Ext rieur Ce mat riau de qualit peut r sister la plupart des produits susceptibles de former des taches ou des piq res de corrosion d autres mat riaux sous r serve que la surface soit maintenue propre et prot g e e Avant la premi re utilisation appliquer un produit de polissage de l acier inoxydable sur toutes les surfaces qui n interviennent pas pendant la cuisson Effectuer une autre application apr s chaque op ration de nettoyage pour viter que la surface subisse des dommages irr versibles Chaque nettoyage devrait tre suivi d un rin age avec de l eau ti de
31. it pas d tincelles on doit SSS remplacer la pile gt 1 Soulever en bas du logement des piles et extraire le porte piles soulever et extraire le porte piles 2 Remplacer la pile par une pile alcaline de 9 volts 3 R installer le porte piles dans le compartiment Nettoyage Conseils g n raux IMPORTANT Avant le nettoyage v rifier que chaque robinet de gaz est en position de fermeture et que tous les br leurs ont refroidi Appliquer les instructions qui accompagnent les produits de nettoyage Pour un nettoyage de routine laver avec eau et savon utiliser une ponge ou un linge doux Rincer avec de l eau propre puis s cher imm diatement avec un linge doux non pelucheux pour viter de laisser des marques et des taches Ne jamais utiliser de la laine d acier pour nettoyer le br leur lat ral ceci laisserait des raflures sur la surface Acier inoxydable IMPORTANT Ne pas utiliser de tampon de r curage savonneux produit de nettoyage abrasif cr me de polissage de table de cuisson laine d acier lavette abrasive ou d essuie tout en papier Ne pas utiliser un produit de nettoyage contenant du chlore qui pourrait endommager la finition Frotter dans la direction du grain pour viter d endommager la surface Apr s un renversement de produit alimentaire nettoyer d s que le br leur lat ral a refroidi Les produits alimentaires renvers s peuvent laisser des taches
32. la plus proche succursale ou le plus proche tablissement de service agr de KitchenAid Canada voir la liste ci dessous S assurer que la soci t de service contact e est agr e pour effectuer l entretien de votre appareil pendant la p riode de garantie Lorsque vous demandez de l assistance ou une intervention veuillez fournir une description d taill e du probl me les num ros complets de mod le et de s rie de l appareil et la date d achat Ces renseignements nous aideront mieux r pondre votre demande Service pour les appareils KitchenAid Canada Service la client le Succursales service en direct COLUMBIE BRITANNIQUE 1 800 665 6788 ALBERTA 1 800 661 6291 ONTARIO exception de l indicatif r gional 807 1 800 267 3456 1 800 807 6777 R gion d Ottawa En dehors de la r gion d Ottawa MANITOBA SASKATCHEWAN et indicatif r gional 807 en Ontario 1 800 665 1683 QUEBEC Quebec 1 800 361 3032 1 800 361 0950 1 800 463 1523 1 800 567 6966 Montr al l exception de la rive Sud Montr al Rive Sud Sherbrooke PROVINCES DE LATLANTIQUE Pour plus d assistance Si vous avez besoin de plus d assistance vous pouvez nous crire en soumettant toute question ou probl me a KitchenAid Canada a Service des relations avec la client le KitchenAid Canada 1901 Minnesota Court Mississauga Ontario L5N 3A7 1 800 565 1598
33. les non vas s Ne pas deformer ni endommager le raccord flexible lors du d placement du br leur lat ral e Il faut utiliser des compos s d tanch it des jointures r sistant au propane Ne pas utiliser de ruban de Teflon robinet ouvert Sy obinet ferm NN L 3 m Ouvrir le robinet d arr t de la canalisation de gaz Le robinet est ouvert lorsque la poign e est parall le la canalisation de gaz 4 m Effectuer un test de recherche des fuites sur chaque connexion l aide d une solution de d tection des fuites non corrosive La formation de bulles indique une fuite Rectifier chaque connexion manifestant une fuite 5 m Soulever prudemment le capot et la grille pour les conserver a part Enlever l emballage autour des br leurs R installer la grille 6 m Ins rer compl tement et avec pr caution le br leur lat ral dans l enceinte d installation m Passer la section Contr le et r glage des br leurs Contr le et r glage des br leurs Les br leurs ont t test s et r gl s l usine pour le fonctionnement au niveau d efficacit optimum Cependant des variations des caract ristiques de la source de gaz et d autres param tres peuvent n cessiter un r glage mineur de l admission d air au niveau des br leurs ou du d bit thermique minimum Tout r glage doit tre ex cut par un technicien qualifi Les op rations de contr le et de r glage des
34. linder See Installation Instructions section When the outdoor cooking gas appliance is not in use the gas must be turned off at the supply cylinder Storage of an outdoor gas side burner appliance indoors is permissible only if the cylinder is disconnected and removed from the outdoor gas side burner Cylinders must be stored outdoors and out of the reach of children and must not be stored in a building garage or any other enclosed area The pressure regulator and hose assembly supplied with the outdoor gas side burner must be used Replacement pressure regulator and hose assembly part number listed in the Installation Instructions section The cylinder supply system must be arranged for proper vapor withdrawal Gas cylinder must include a collar to protect the cylinder valve WARNING If the information in this manual is not followed exactly a fire or explosion may result causing property damage personal injury or death If the following information is not followed exactly a fire causing death or serious injury may occur e Do not store a spare LP gas cylinder under or near this side burner e Never fill the cylinder beyond 80 percent full IMPORTANT This side burner is manufactured for outdoor use only For side burners that are to be used at elevations above 2000 feet orifice conversion is required See Gas supply requirements section It is the responsibility
35. mall difficult to clean areas use Whirlpool Degreaser Part No 31552 a commercial degreaser designed for stainless steel See Requesting Assistance or Service section to order Burner caps and grate e Clean with a brass bristle brush e Wash grate using mild detergent warm water and degreaser e Rinse with clean water and dry with soft lint free cloth e Use Stainless Steel Cleaner amp Polish Part No 4396095 See Requesting Assistance or Service section to order Knobs plastic and flange area around knobs IMPORTANT Do not use steel wool abrasive cleaners or oven cleaner Do not soak knobs e Wash with mild detergent using a soft cloth and warm water Rinse and dry Control panel graphics IMPORTANT Do not use steel wool abrasive cleaners or oven cleaner Do not spray cleaner directly onto panel Clean around the burner labels gently scrubbing may remove printing e Wash with mild detergent using a soft cloth and warm water Rinse and dry EEE Warranty KitchenAid Gas Side Burner Warranty LENGTH OF WARRANTY KitchenAid WILL PAY FOR FULL ONE YEAR WARRANTY Factory Specified Parts and Repair Labor to correct defects in materials OR work From Date of Purchase manship Service must be provided by a Service Company designated by KitchenAid Limited Five Year Warranty For five years from the date of purchase when this gas side burner is used in Second through Fifth
36. ntaire Ne pas laisser des aliments en attente pendant plus d une heure avant ou apr s la cuisson Le non respect de ces instructions peut causer une intoxication alimentaire ou une maladie k Enlever le capot du br leur lat ral Ne pas allumer les br leurs avec le capot rabattu 2 V rifier que chaque bouton de commande est la position de fermeture 3 Ouvrir l arriv e de gaz Gaz naturel ou gaz propane d un fournisseur local e Utilisation d une source d alimentation de gaz autre qu une bouteille de gaz propane Tourner le robinet d arr t la position ouverte de la canalisation d alimentation de gaz Bouteille de propane s il y a conversion voir Alimentation en gaz Sp cifications e Utilisation d une bouteille de propane Ouvrir lentement pas brusquement le robinet de la bouteille de gaz NOTE En cas d activation du dispositif de limitation du d bit il peut tre impossible d allumer le gril S il demeure possible d allumer le gril la taille des flammes et le d bit thermique seront insuffisants Dans ce cas fermer le robinet de la bouteille de gaz et tous les robinets de commande des br leurs et attendre 30 secondes Apr s cela ouvrir tr s lentement le robinet de la bouteille de gaz et attendre 5 secondes avant d entreprendre l allumage IMPORTANT Allumer un seul br leur la fois 1 L utilisateur ne doit pas se pencher au dessus des br leurs
37. propre Pour le s chage essuyer compl tement la surface avec un linge doux Pour les taches tenaces ou de graisse carbonis e utiliser le d graissant Whirlpool article no 31552 il s agit d un d graissant commercial pour acier inoxydable Voir la section Demande d assistance et de service pour commander Int rieur e Chaque nettoyage devrait tre suivi d un rin age avec de l eau ti de propre Utiliser un d tergent liquide doux d tergent vaisselle ou un produit de nettoyage polyvalent en suivant les instructions fournies avec le produit Rincer avec de l eau propre et s cher avec un linge doux non pelucheux On peut utiliser une ponge r curer service rigoureux avec un produit de nettoyage doux Toujours frotter dans la direction du grain e Pour une zone de petite taille et difficile nettoyer utiliser le d graissant Whirlpool article no 31552 il s agit d un d graissant commercial pour acier inoxydable Voir la section Demande d assistance et de service pour commander Grille et chapeaux du br leur lat ral e Nettoyer avec une brosse soies de laiton e Laver la grille avec un d tergent doux de l eau ti de et un d graissant e Rincer l eau propre et essuyer avec un chiffon doux non pelucheux e Utiliser le produit de polissage Stainless Steel Cleaner amp Polish article n 4396095 Pour la commande voir la section Demande d assistance ou de
38. ranty gives you specific legal rights and you may also have other rights which vary from state to state or province to province Outside the 50 United States and Canada this warranty does not apply Contact your authorized KitchenAid dealer to determine if another warranty applies If you need customer or technical assistance first see the Using your Side Burner section of the book Additional help can be found by calling the KitchenAid Customer Interaction Center at 1 800 422 1230 from anywhere in the U S A and 1 800 807 6777 from anywhere in Canada Requesting Assistance or Service To avoid unnecessary service calls please check the Use and Care of your Side Burner section It may save you the cost of a service call If you still need help follow the instructions below If you need assistance or service in U S A Call toll free at 1 800 422 1230 our consultants are available to assist you When calling Please know the purchase date and the complete model and serial number of your appliance This information will Our consultants provide assistance with e Features and specifications on our full line of appliances e Installation information If you need replacement parts If you need to order replacement parts we recom mend that you only use factory authorized parts These parts will fit right and work right because they are made to the same exacting specifications used to build every new KitchenA
39. s pr cises appliqu es lors de la fabrication de chaque nouvel appareil m nager KitchenAid Pour localiser des pi ces de rechange d origine dans votre r gion composer le 1 800 422 1230 pour obtenir l adresse du plus proche centre de service agr ou contacter le d partement de service apr s vente de KitchenAid au 1 800 442 1111 Pour plus d assistance Si vous avez besoin de plus d assistance vous pouvez nous crire en soumettant toute question ou probl me KitchenAid Brand Home Appliances Customer Interaction Center c o Correspondence Dept 2000 North M 63 Benton Harbor MI 49022 2692 Veuillez indiquer dans votre correspondance un num ro de t l phone o l on peut vous joindre durant la journ e 10 Demande d assistance ou de service Avant de nous contacter pour de l assistance ou un service veuillez consulter la section Utilisation et entretien du br leur lat ral Ceci pourrait vous viter le co t d une intervention de d pannage Si une assistance demeure n cessaire proc der selon les instructions ci dessous Si vous avez besoin d assistance ou de service au Canada 1 Si le probleme n est pas attribuable l une des causes indiqu es dans D pannage Contr le du fonctionnement gt Communiquer avec le commer ant qui a vendu l appareil lectrom nager ou t l phoner sans frais au 1 800 422 1230 2 Si vous avez besoin de service Communiquer avec
40. situ e sur le panneau lat ral KitchenAid Num ro de mod le BIEN PENSE BIEN FABRIQUE Num ro de s rie Article n 8190046 Avant de commencer Votre s curit et celle des autres c est tr s important Nous donnons de nombreux messages de s curit importants dans ce manuel et sur votre appareil m nager Veillez toujours lire tous les messages de s curit et vous y conformer Voici le symbole d alerte de s curit Ce symbole d alerte de s curit vous signale un risque potentiel de d c s et de blessures graves pour vous et d autres personnes Tous les messages de s curit suivront le symbole d alerte de s curit et le mot DANGER ou AVERTISSEMENT Ces mots signifient ADANGER Risque possible de d c s ou de blessure grave si vous ne suivez pas imm diatement les instructions AVERTISSEMENT Risque possible de d c s ou de blessure grave si vous ne suivez pas les instructions Chaque message de s curit identifie le danger potentiel et indique comment r duire le risque de blessure et ce qui peut se produire en cas de non respect des instructions POUR VOTRE S CURIT SI UNE ODEUR DE GAZ EST PERCEPTIBLE e Fermer l arriv e de gaz de l appareil e teindre toute flamme nue e Ouvrir le capot e Si l odeur persiste contacter imm diatement le fournisseur de gaz ou les pompiers POUR VOTRE S CURIT e Ne pas remiser
41. t jamais obstru es 8 Inspecter le tuyau raccordant la bouteille de gaz au br leur lat ral avant chaque utilisation de l appareil En cas de coupure usure ou abrasion excessive on DOIT remplacer le tuyau de raccordement avant d utiliser le br leur lat ral Consulter le revendeur utiliser uniquement un tuyau de remplacement sp cifi pour l utilisation avec le br leur lat ral pour ext rieur 9 Inspecter visuellement les flammes sur les br leurs On doit observer des flammes bleues une petite zone jaun tre l extr mit des flammes est normale lors de l alimentation au propane 10 Inspecter les br leurs et le tube venturi pour y rechercher des accumulations d insectes ou nids d insectes Une obstruction du tube peut provoquer un feu sous le br leur lat ral 11 La bouteille de gaz utilis e doit e tre fabriqu e conform ment aux sp cifications applicables aux bouteilles de propane et tre marqu e comme telle sp cifications du minist re des Transports des E U ou de la norme canadienne CAN CSA B339 r cipients pour le transport de mati res dangereuses et Commission comporter un dispositif homologu emp chant un remplissage excessif comporter un dispositif de raccordement compatible avec le raccord d alimentation du br leur lat ral pour ext rieur 12 Inspecter toujours les connexions pour rechercher les fuites lors de chaque raccordement d connexion de la
42. t ral doit tre raccord une source de gaz sous pression r gul e e Les puissances thermiques indiqu es sur la plaque signal tique ont t d termin es pour une altitude de 2000 pieds 610 m une altitude sup rieure 2000 pieds 610 m la puissance thermique diminue raison de 4 pour chaque tranche de 1000 pieds 305 m au dessus du niveau de la mer Un remplacement du gicleur est n cessaire Contacter le centre d assistance la client le KitchenAid La plaque signal tique indique le type de gaz utiliser Si le gaz sp cifi ne correspond pas au type de gaz disponible consulter le fournisseur local de gaz Ne jamais entreprendre de convertir le br leur lat ral pour l alimentation avec un gaz autre que celui qui est sp cifi sur la plaque signal tique sans avoir consult le fournisseur de gaz local On devra utiliser l ensemble de conversion sp cifi Test de pressurisation de la canalisation Test plus de 1 2 Ib po2 3 5 kPa relative ou colonne d eau de 14 po 35 5 cm Lors de tout test de pressurisation de la canalisation de gaz une pression relative sup rieure 1 2 Ib po 3 5 kPa il faut que le br leur lat ral et son robinet d arr t individuel soient d connect s de la canalisation d arriv e de gaz Test une pression de 1 2 Ib po 2 3 5 kPa relative ou colonne d eau de 14 po 35 5 cm ou moins Lors de tout test de pressurisation de la canalisation
43. tions du Code national du gaz NFPA 54 et des codes locaux Pour la conversion pour l alimentation au propane on doit utiliser l ensemble de conversion no 4396312 Suivre les instructions fournies avec l ensemble Conversion pour l alimentation au propane depuis une bouteille de propane Pour la conversion pour l alimentation au propane on doit utiliser l ensemble de conversion no 4396312 Suivre les instructions fournies avec l ensemble On doit acqu rir s par ment une bouteille de propane pas plus de 20 Ib GAZ NATUREL Pression de service 4 po 10 2 cm colonne d eau Pression d alimentation 7 14 po maximum 17 8 cm a 35 5 cm colonne d eau GAZ PROPANE Pression de service 11 po 28 cm colonne d eau Pression d alimentation 11 a 14 po 28 a 35 5 cm colonne d eau Installation du br leur lat ral AVERTISSEMENT Risque de poids excessif Deux personnes ou plus sont n cessaires pour d placer et installer le br leur lat ral Le non respect de cette instruction peut causer une blessure au dos ou une autre blessure Alimentation au gaz naturel Le circuit de gaz doit satisfaire les prescriptions des codes et r glements locaux En l absence de codes locaux les installations doivent satisfaire soit les prescriptions du Code national du gaz ANSI Z223 1 soit celles du code d installation de gaz naturel et propane CAN CGA B149 1 1 m Placer le br leur lat ral
44. to OFF and wait 5 minutes before relighting If any burners do not light after attempting to manually light them contact the KitchenAid Assistance Center see Requesting Assistance or Service section Replacing the Igniter battery If igniters stop sparking the battery should be Q replaced i Lift up at bottom of battery tray and slide battery tray out N Remove battery and replace with alkaline 9 volt battery 3 Slide battery tray back lift up and into compartment slide out tray Cleaning General Tips IMPORTANT Before cleaning make sure all controls are off and the burners are cool Always follow label instructions on cleaning products For routine cleaning wash with soap and water using a soft cloth or sponge Rinse with clean water and dry at once with a soft lint free cloth to avoid spots and streaks Never use steel wool to clean the side burner as it will scratch the surface Stainless Steel IMPORTANT Do not use soap filled scouring pads abrasive cleaners Cooktop Polishing Creme steel wool gritty wash cloths or paper towels Cleaners should not contain chlorine Damage may occur to the product finish Rub in direction of grain to avoid scratching or damaging the surface Food spills should be cleaned as soon as entire Side Burner is cool Spills may cause permanent discoloration e Use Stainless Steel Cleaner amp Polish Part 4396095 See Requestin
45. to wind and traffic paths The location should be away from strong draft areas Do not obstruct flow of combustion and ventilation air Gas supply requirements Observe all governing codes and ordinances Important Side burner must be connected to a regulated gas supply e Input ratings shown on the model serial rating plate are for elevations up to 2 000 feet 610 m For elevations above 2 000 feet 610 m ratings are reduced at a rate of 4 for each 1 000 feet 305 m above sea level Orifice conversion is required Contact KitchenAid Assistance Center Refer to the model serial rating plate for information on the type of gas that can be used If this information does not agree with the type of gas available check with your local gas supplier No attempt shall be made to convert the side burner from the gas specified on the model serial rating plate for use with a different gas type without consulting the serving gas supplier The conversion kits specified must be used Line pressure testing Testing above 1 2 psi 3 5 kPa or 14 inches 35 5 cm W C gauge The side burner and its individual shutoff valve must be disconnected from the gas supply piping system during any pressure testing of that system at test pressures greater than 1 2 psig 3 5 kPa Testing below 1 2 psi 3 5 kPa or 14 inches 35 5 cm W C gauge or lower The side burner must be isolated from the gas supply piping system by closing i
46. ts individual manual shutoff valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1 2 psig 3 5 kPa Built in Side Burners Natural Gas Side burner are equipped for use with Natural gas They are design certified by CSA International for L P propane or butane gases with appropriate conversion Side burners are set for natural gas use and have a pressure regulator with 1 2 female pipe threads shutoff valve open position gas supply line to side burner The supply line shall be equipped with an approved shutoff valve This valve should be located in the same area as the side burner and should be in a location that allows ease of opening and closing Do not block access to the shutoff valve The valve is for turning on or shutting off gas to the appliance L P Gas Conversion L P gas conversion from a local L P gas supply Conversion must be made by a qualified gas technician The qualified natural gas technician shall provide the L P gas supply to the selected side burner location in accordance with the National Fuel Gas Code NFPA 54 and local codes To convert to L P gas the L P Gas Conversion Kit No 4396312 must be used Follow Instructions included with kit L P gas conversion using a L P fuel tank To convert to L P gas the L P Gas Conversion Kit No 4396312 must be used Follow Instructions included with kit A L
47. u titre de dommages secondaires ou indirects Toute garantie implicite de qualit marchande ou d aptitude du produit pour une application particuli re est limit e dans le temps a la dur e de validit de cette garantie Certaines provinces ne permettent pas l exclusion ou la limitation des dommages secondaires ou indirects ou la limitation de la dur e de validit des garanties implicites par cons quent ces exclusions ou limitations peuvent ne pas vous tre applicables Cette garantie vous conf re des droits juridiques sp cifiques vous pouvez galement jouir d autres droits variables d une province une autre Hors des tats Unis et du Canada cette garantie ne s applique pas Contactez votre revendeur KitchenAid agr pour d terminer si une autre garantie s applique Pour tout besoin d assistance consulter d abord la section Utilisation du br leur lat ral dans cette brochure Pour obtenir une aide additionnelle contacter le centre d interaction avec la client le KitchenAid au 1 800 422 1230 aux E U ou au 1 800 807 6777 au Canada Demande d assistance ou de service Pour viter des interventions de d pannage non n cessaires veuillez consulter la section Utilisation et entretien du br leur lat ral Ceci pourrait vous viter le co t d une intervention de d pannage Si une assistance demeure n cessaire proc der selon les instructions ci dessous LA Si vous avez besoin d assistanc

Download Pdf Manuals

image

Related Search

Related Contents

COMMON RAIL SYSTEM (CRS) SERVICE MANUAL : Operation  Sony IPT-DS1 Notes    SCM: ADF Property Programs  Technical Manual and Replacement Parts List Freezer  Visual C++ 6.0 Tutorial  MANUALE USO E MANUTENZIONE  JVC KD-S731R User's Manual  manual do usuário dermovac chronos system  参考2(PDF:645KB)  

Copyright © All rights reserved.
Failed to retrieve file