Kidde KN-COSM-IBA User's Manual

image

Contents

1. 2014 5 29 4 35 2 Kidde 5 United Technologies User Guide for Model KN COSM IBA Combination Smoke and Carbon Monoxide Alarm e 120V AC e 2 AA Battery Backup e 2 LED Display e Peak Level Memory e Test Hush button e Voice Message System Kidde cf TWIST as Ma PUSHTO TES SIGNALING LISTED For questions concerning your Smoke and Carbon Monoxide Alarm please call our Product Support Line at 1 800 880 6788 For your convenience write down the following information If you call our Product Support Line these are the first questions you will be asked Alarm Model Number located on back of the alarm Date of Manufacture located on back of the alarm Date of Purchase Where Purchased READ AND SAVE THIS USER GUIDE P N 2544 7201 01 EN 2014 5 29 4 35 PM Table of Contents Introduction Page 1 Product View Pages 2 3 Features oouo o heed apache ade dek we Pages 4 7 Installation Instructions Step 1 Installation Instructions A Recommended Installation Locations Pages 8 10 Where Not to Install Page 10 Step 2 Wiring Instructions Page 11 12 Step 3 Mounting Instructions Page 13 14 Step 4 Testing the Alarm Page 14 Operating Instructions Intercon
2. reads as follows gt Smoke Detection Where L required by applicable laws FIRE EXTINGUISHERS codes or standards for the specified occupancy approved smoke ararms single and multiple station CARBON MONOMDE smoke alarms shall be installed ALARMS as follows 1 In all sleeping rooms Exception Smoke alarms shall not be required in sleeping rooms in existing one and two family dwelling units 2 Outside of each separate sleeping area in immediate vicinity of the sleeping rooms 3 On each level of the dwelling unit including basements Exception In existing one and two family dwelling units approved smoke alarms powered by batteries are permitted Smoke Detection Are More Smoke Alarms Desirable The required number of smoke alarms might not provide reliable early warning protection for those areas separated by a door from the areas protected by the required smoke alarms For this reason it is recommended that the householder consider the use of additional smoke alarms for those areas for increased protection The additional areas include the basement bedrooms dining room furnace room utility room and hallways not protected by the required smoke alarms The installation of smoke alarms in kitchens attics finished or unfinished or garages is not normally recommended as these locations occasionally experience conditions that can result in improper operation
3. California State Fire Marshall Early warning fire detection is best achieved by the installation of fire detection equipment in all rooms and areas of the household as follows A smoke alarm installed in each separate sleeping area in the vicinity but outside the bedrooms heat or smoke detectors in the living rooms dining rooms bedrooms kitchens hallways attics furnace rooms closets utility and storage rooms basements and attached garages 27 4 2014 5 29 4 35 PM Industry Safety Standards Consumer Product Safety Commission The Consumer Product Safety Commission CPSC recommends the use of at least one CO Alarm per household located near the sleeping area NRC lonization type smoke alarms use a very small amount of a radioactive element in the sensing chamber to enable detection of visible and invisible combustion products The radioactive element is safely contained in the chamber and requires no adjustments or maintenance This smoke alarm meets or exceeds all government standards It is manufactured and distributed under license from the U S Nuclear Regulatory Commission FCC COMPLIANCE STATEMENT This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate rad
4. are positioned A the small ends of the keyholes before tightening the screws rom the connector pins and plug 2 he back ofthe alam figure FIGURES 4 making sure that the locks on 9 connector snap into place Then push the excess wire back into the electrical box through the hole in the center of the mounting bracket Connect Install the alarm on the mounting bracket and rotate the alarm in the direction of the ON arrow on the cover until the alarm ratchets into place this ratcheting function allows for aesthetic alignment Note The alarm will mount to the bracket in 4 positions every 90 degrees 13 4 2014 5 29 4 35 PM Installation Instructions 7 Turn on the AC power The green AC Power On Indicator should be lit when the alarm is operating from AC power 8 Two labels are included with your alarm They have important information on what to do in case of an alarm Add the phone number of your emergency service provider Fire Department or 911 in the space provided Place one label next to the alarm after it is mounted and one label near a fresh air source such as a door or window 9 Remove the red cardboard from the battery compartment install batteries close battery door Step 4 Testing the Alarm A CAUTION Due to the loudness 85 decibels of the alarm always stand an arms length away from the unit when testing After installation TES
5. dryers water heaters portable fuel burning space heaters fireplaces wood burning stoves and certain swimming pool heaters Blocked chimneys or flues back drafting and changes in air pressure corroded or disconnected vent pipes and a loose or cracked furnace exchanger can also cause CO Vehicles and other combustion engines running in an attached garage and using a charcoal gas grill or hibachi in an enclosed area are all possible sources of CO The following conditions can result in transient CO situations Excessive spillage or reverse venting of fuel burning appliances caused by outdoor ambient conditions such as Wind direction and or velocity including high gusts of wind heavy air in the vent pipes cold humid air with extended periods between cycles negative pressure differential resulting from the use of exhaust fans simultaneous operation of several fuel burning appliances competing for limited internal air vent pipe connections vibrating loose from clothes dryers furnaces or water heaters obstructions in or unconventional vent pipe designs which can amplify the above situations extended operation of unvented fuel burning devices range oven fireplace etc temperature inversions which can trap exhaust gasses near the ground car idling in an open or closed attached garage or near a home 24 4 2014 5 29 4 35 PM Carbon Monoxide Safety Information CO Safety Tips Every year have the heatin
6. the alarm see page 17 Battery reminder flag that prohibits installation when batteries are not present 2014 5 29 4 35 PM Features General Information Smoke Alarm The smoke alarm monitors the air for products of combustion that are produced when something is burning or smoldering When smoke particles in the smoke sensor reach a specified concentration the alarm voice message warning system will sound and be accompanied by the flashing red LED light The smoke alarm takes precedence when both smoke and carbon monoxide are present A WARNING PLEASE READ CAREFULLY AND THOROUGHLY NFPA 72 states Life safety from fire in residential occupancies is based primarily on early notification to occupants of the need to escape followed by the appropriate egress actions by those occupants Fire warning systems for dwelling units are capable of protecting about half of the occupants in potentially fatal fires Victims are often intimate with the fire too old or young or physically or mentally impaired such that they cannot escape even when warned early enough that escape should be possible For these people other strategies such as protection in place or assisted escape or rescue are necessary Smoke alarms are devices that can provide early warning of possible fires at a reasonable cost however alarms have sensing limitations lonization sensing alarms may detect invisible fire particles associated with fast fla
7. warranty shall not apply to the alarm if it has been damaged modified abused or altered after the date of purchase or if it fails to operate due to improper maintenance or inadequate AC or DC power Any implied warranties arising out of this sale including but not limited to the implied warranties of description merchantability and fitness for a particular purpose are limited in duration to the above warranty period In no event shall the Manufacturer be liable for loss of use of this product or for any indirect special incidental or consequential damages or costs or expenses incurred by the consumer or any other user of this product whether due to a breach of contract negligence strict liability in tort or otherwise The Manufacturer shall have no liability for any personal injury property damage or any special incidental contingent or consequential damage of any kind resulting from gas leakage fire or explosion Since some states do not allow limitations of the duration of an implied warranty or do not allow the exclusion or limitation of incidental or consequential damages the above limitations or exclusions may not apply to you While this warranty gives you specific legal rights you may also have other rights which vary from state to state Also KIDDE makes no warranty express or implied written or oral including that of merchantability or fitness for any particular purpose with respect to the battery 29 4
8. 0 6788 or write us at Kidde Products 1016 Corporate Park Dr Mebane NC 27302 Our internet address is www kidde com 30 2014 5 29 4 35 PM QUESTIONS OR FOR MORE INFORMATION Call our Product Support Line at 1 800 880 6788 or contact us at our website at www kidde com g Kidde United Technologies Kidde 1016 Corporate Park Drive Mebane NC 27302 Custom Assembled in China with U S and Foreign Components 4
9. 112040 112060 112060 14618 i4618A 5 RF SM ACDC 120 P12040 2000 Pi2010 5 KN COSM IB Kidde Firex 14618 i4618A Heat alarm HD135F alarms KN COP IC Relay modules 5 120 CO120X Strobe Light SL177i SLED177i For more information about compatible interconnect units and their functionality in an interconnect system visit our web site at www kidde com Smoke HUSH Control Feature The HUSH feature has the capability of temporarily desensitizing the smoke alarm circuit for approximately 9 minutes This feature is to be used only when a known alarm condition such as smoke from cooking activates the alarm When the unit is in alarm You can put your Smoke CO Alarm in HUSH mode by pushing the test reset button If the smoke is not too dense the alarm will silence immediately the unit will verbally announce HUSH MODE ACTIVATED and the green LED will flash every 2 seconds for approximately 9 minutes This indicates that the smoke alarm is in a temporarily desensitized condition Your Smoke CO Alarm will automatically reset after approximately 9 minutes When the unit returns to normal operation after being in HUSH mode it will verbally announce HUSH MODE CANCELLED and sound the alarm if smoke is still present The HUSH feature can be used repeatedly until the air has been cleared of the condition causing the alarm While the u
10. MODE ACTIVATED when the unit is first put into HUSH Mode Only for smoke alarm Hush 4 2014 5 29 4 35 PM Features System announces HUSH MODE CANCELLED when unit resumes normal operation after Hush Mode has been cancelled Only if button is pushed System announces CAUTION CARBON CONOXIDE PREVIOUSLY DETECTED when the unit has detected CO concentrations of 100 ppm or higher System announces PUSH TEST BUTTON when the unit is powered up reminding user to activate the Test Button End of Life Hush At end of product life the button can be pushed to silence the end of life chiro for approximately 3 days at a time for a maximum of 30 days life extension One chirp every 30 seconds coupled with a green LED flash twice a second is an indication that the alarm is malfunctioning If this occurs call the Product Support Line at 1 800 880 6788 Test Reset button performs functions See page 14 HUSH Control Feature that silences the unit during nuisance alarm situations see page 15 Peak Level Memory Feature which alerts user when the unit has detected CO concentrations of 100 ppm or greater see page 16 Alarm Memory Feature that gives visual indication when an alarm has sensed a hazardous condition Green and red LED lights that indicate normal operation and alarm status see page 16 and 17 for details Tamper Resist Feature that deters children and others from removing
11. QUIREMENTS This smoke alarm should be installed on a ULL listed or recognized junction box All connections should be made by a qualified electrician and all wiring used shall be in accordance with articles 210 and 300 3 B of the U S National Electrical Code ANSI NFPA 70 NFPA 72 and or any other codes having jurisdiction in your area The multiple station interconnect wiring to the alarms must be run in the same raceway or cable as the AC power wiring In addition the resistance of the interconnect wiring shall be a maximum of 10 ohms The appropriate power source is 120 Volt AC Single Phase supplied from a non switchable circuit which is not protected by a ground fault interrupter Smoke alarms are not to be used with detector guards unless the combination alarm and detector guard have been evaluated and found suitable for that purpose A WARNING The alarm cannot be operated from power derived from a square wave modified square wave or modified sine wave inverter These types of inverters are sometimes used to supply power to the structure in off grid installations such as solar or wind derived power sources These power sources produce high peak voltages that will damage the alarm N WIRING INSTRUCTIONS FOR AC QUICK CONNECT HARNESS CAUTION TURN OFF THE MAIN POWER TO THE CIRCUIT BEFORE WIRING THE ALARM For alarms that are used as single station DO NOT CONNECT THE RED WIRE TO ANYTHING Leave the red wire insulati
12. T THE UNIT S ELECTRONICS by pressing and releasing the test reset button You will then hear the following sequence of beeps and verbal warnings Three long beeps Verbal warning FIRE Three long beeps Four quick beeps Verbal warning WARNING CARBON MONOXIDE Four quick beeps Single beep to reset Weekly testing is required If at anytime it does not perform as described verify power is connected correctly and that the battery doesn t need replacing Clean dust and other buildup off the unit If it still doesn t operate properly call the Product Support Line at 1 800 880 6788 Interconnect Feature Your Combination Smoke CO Alarm is interconnectable to other multiple station Kidde Nighthawk and Kidde Fyrnetics products When compatible smoke alarms and heat alarms interconnected to your Smoke CO Alarm they will only respond to a smoke related event 14 4 2014 5 29 4 35 PM Operating Instructions When mixing compatible models with battery backup with models without battery backup be advised that the models without battery backup will not respond during an AC power failure This unit is only approved to interconnect with other Kidde Nighthawk products It is NOT approved to interconnect with any other brand of detection product This alarm is interconnect compatible with the following alarms and accessories Smoke alarms 1235 1275 1276 1285 112020 i12020A 112040
13. ages kitchens furnace rooms or bathrooms INSTALL AT LEAST 5 FEET AWAY FROM ANY FUEL BURNING APPLIANCE Do not install within 3 ft 9m of the following The door to a kitchen or a bathroom that contains a tub or shower forced air supply ducts used for heating or cooling ceiling or whole house ventilating fans or other high air areas Avoid excessively dusty dirty or greasy areas Dust grease or household chemicals can contaminate the alarm s sensors causing it to not operate properly Place the alarm where drapes or other objects will not block the sensor Smoke and CO must be able to reach the sensors to accurately detect these conditions Do not install in peaks of vaulted ceilings A frame ceilings or gabled roofs Keep out of damp and humid areas Install at least one 1 foot away from fluorescent lights electronic noise may cause nuisance alarms Do not place in direct sunlight and keep out of insect infested areas Extreme temperatures will effect the sensitivity of the Smoke CO Alarm Do not install in areas where the temperature is colder than 40 degrees Fahrenheit 4 4 Celsius or hotter than 100 degrees Fahrenheit 37 8 Celsius such as garages and unfinished attics Do not install in areas where the relative humidity RH is above 85 Place away from doors and windows that open to the outside 10 4 2014 5 29 4 35 Installation Instructions Step 2 Wiring Instructions WIRING RE
14. ct Wiring Diagram WIRES ON ALARM HARNESS CONNECTED TO Black Hot Side of AC Line White Neutral Side of AC Line Red Interconnect Lines Red Wires of Other Units in the Multiple Station Set up 12 4 2014 5 29 4 35 PM Installation Instructions Step 3 Mounting Instructions A CAUTION YOUR SMOKE CO ALARM IS SEALED AND THE COVER IS NOT REMOVABLE 1 Remove the cardboard square A To help identify the date to replace the unit write the Replace by date 10 years from initial power up in permanent marker in the space provided on the side of the alarm See Alarm Replacement section for additional information Remove the mounting bracket from the back of the alarm by holding the mounting bracket and twisting the alarm in the direction indicated by the OFF arrow on the alarm cover After selecting the proper location for your Smoke CO Alarm as described on Pages 8 10 and wiring the AC QUICK CONNECT harness as described in the WIRING INSTRUCTIONS NOTE AC power should be turned off at this stage attach the mounting bracket to the electrical box To ensure aesthetic alignment of the alarm with the hallway or wall the line on the mounting bracket must be parallel with the hallway when ceiling mounted or horizontal when wall mounted Pull the AC QUICK CONNECTOR through the center hole in he mounting bracket and secure he bracket making sure that the mounting screws
15. e will occur once every minute and will continue for at least seven days On battery power the LOW BATTERY voice occurs once every 15 minutes If the red LED light flashes along with a chirp every 30 seconds and is not followed by the voice message LOW BATTERY as described above and if the green LED flashes twice per second AC power only your unit has malfunctioned Call our toll free Product Support Line at 1 800 880 6788 for instructions how to return the unit BATTERY INSTALLATION AND REMOVAL To replace or install the batteries slide the battery door in the direction indicated on the cover of the alarm When installing new batteries into the carrier make sure that the polarity matches the markings printed on the inside of the battery compartment press the battery reminder finger down into the battery compartment and install the battery see Figure 6 Completely slide the battery door to the closed position A missing or improperly installed battery will prevent the battery door from closing and result in improper alarm operation Battery 2 finger 4 OPEN INSERT 21 E 2014 5 29 4 35 PM Battery Replacement Replace batteries with one of the following approved brands Duracell MN1500 1500 Energizer E91 Gold Peak 15 or Golden Power GLR6A These batteries be purchased at your local retailer WARNING Use only the batteries specified Use of different batteries ma
16. g system vents chimney and flue inspected and cleaned by a qualified technician Always install appliances according to manufacturer s instructions and adhere to local building codes Most appliances should be installed by professionals and inspected after installation Regularly examine vents and chimneys for improper connections visible rust or stains and check for cracks in furnace heat exchangers Verify the color of flame on pilot lights and burners is blue A yellow or orange flame is a sign that the fuel is not burning completely Teach all household members what the alarm sounds like and how to respond Symptoms of CO Poisoning Initial carbon monoxide poisoning symptoms are similar to the flu with no fever and can include dizziness severe headaches nausea vomiting and disorientation Everyone is susceptible but experts agree that unborn babies pregnant women senior citizens and people with heart or respiratory problems are especially vulnerable If symptoms of carbon monoxide poisoning are experienced seek medical attention immediately CO poisoning can be determined by a carboxyhemoglobin test The following symptoms are related to CARBON MONOXIDE POISONING and should be discussed with ALL members of the household 1 Mild Exposure Slight headache nausea vomiting fatigue often described as Flu like symptoms 2 Medium Exposure Severe throbbing headache drowsiness confusion fast heart rate 3 Extreme Exp
17. ile the alarm is in HUSH mode Tamper Resist Feature To make your smoke CO alarm tamper resistant a tamper resist feature has been provided Activate the tamper resist feature by breaking off the four posts in the square holes in the trim ring see figure 5A When the posts are broken off the tamper resist tab on the base is allowed to engage the mounting bracket Rotate the alarm onto the mounting bracket until you hear the tamper resist tab snap into place locking the alarm on the mounting bracket Using the tamper resist feature will help deter children and others from removing the alarm from bracket NOTE To remove the alarm when the tamper resist tab is 4 17 2014 5 29 4 35 PM Operating Instructions FIGURE 5A FIGURE 5B engaged press down on the tamper resist tab and rotate the alarm off of the bracket see figure 5B NEVER IGNORE THE SOUND OF THE ALARM Determining what type of alarm has sounded is easy with your Combination Smoke CO Alarm The voice message warning system will inform you of the type of situation occurring Refer to the Features section on pages 4 7 for a detailed description of each alarm pattern What To Do If The Alarm Sounds When the smoke alarm sounds Smoke alarms are designed to minimize false alarms Cigarette smoke will not normally set off the alarm unless the smoke is blown directly into the alarm Combustion particles from cooking may set off the alarm if
18. ill flash as described below under the following conditions During smoke or CO alarm with every beep During testing same as alarm Low battery single flash with chirp End of product life double flash every 30 seconds with chirp Unit error mode single flash with chirp every 30 seconds Unit error mode a Fault Code is flashed every 30 seconds can be observed and reported to customer service for troubleshooting 16 2014 5 29 4 35 PM Operating Instructions Green LED The green LED will flash as described below under the following conditions Standby Condition powered by AC and battery backup The LED will be constantly on Standby Condition powered by only battery backup The LED will flash every 60 seconds Alarm Memory Condition The LED will flash every second during alarm When the alarm condition goes away the originating alarm unit will flash the LED every 16 seconds until the test reset button is pressed thus resetting the alarm Peak Memory 10 second flash rate AC powered only Indicates CO greater than 100PPM was detected Press Test button to announce Peak message and clear Peak Memory Initiating Alarm condition 1 second flash rate indicates the unit initiated an alarm Trouble Fault Error mode 1 2 second flash rate AC powered only Helps owner locate the mysterious chirping unit HUSH MODE Condition The LED will flash every 2 seconds wh
19. indow until the emergency services responders have arrived the premises has been aired out and your alarm remains in its normal condition 4 After following steps 1 3 if your alarm reactivates within a 24 hour period repeat steps 1 3 and call a qualified appliance technician PHONE NUMBER to investigate for sources of CO from fuel burning equipment and appliances and inspect for proper operation of this equipment If problems are identified during this inspection have the equipment serviced immediately Note any combustion equipment not inspected by the technician and consult the manufacturer s instructions or contact the manufacturer s directly for more information about CO safety and this equipment Make sure that motor vehicles are not and have not been operating in an attached garage or adjacent to the residence Never restart the source of a CO problem until it has been fixed NEVER IGNORE THE ALARM 20 4 2014 5 29 4 35 PM Battery Replacement Alarm Removal IF TAMPER RESIST FEATURE HAS BEEN ACTIVATED REFER TO TAMPER RESIST FEATURE DESCRIPTION ON PAGE 17 FOR REMOVAL INSTRUCTIONS Remove the alarm from the mounting bracket by rotating the alarm in the direction of the OFF arrow on the cover Battery Replacement If any form of battery failure is detected the red LED light will flash and the unit will chirp one time followed by the warning message LOW BATTERY This cycl
20. instance a smoking in bed b leaving children unsupervised c cleaning with flammable liquids such as gasoline The CO sensor meets the alarm response time requirements of UL standard 2034 Standard alarm times are as follows At 70 PPM the unit must alarm within 60 240 minutes At 150 PPM the unit must alarm within 10 50 minutes At 400 PPM the unit must alarm within 4 15 minutes This carbon monoxide alarm is designed to detect carbon monoxide gas from ANY source of combustion It is NOT designed to detect any other gas Fire Departments most utility companies and HVAC contractors will perform CO inspections some may charge for this service It s advisable to inquire about any applicable fees prior to having the service performed Kidde Safety will not pay for or reimburse the owner or user of this product for any repair or dispatch calls related to the alarm sounding 19 4 2014 5 29 4 35 PM What Do If The Alarm Sounds When the carbon monoxide alarm sounds WARNING Actuation of your CO Alarm indicates the presence of Carbon Monoxide which kill If alarm signal sounds 1 Operate the test reset button 2 Call your emergency PHONE NUMBER services Fire Dept or 911 3 Immediately move to fresh air outdoors or by an open door window Do a head count to check that all persons are accounted for Do not reenter the premises nor move away from the open door w
21. io frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help 28 ks 2014 5 29 4 35 PM Warranty and Service Information Limited Warranty TEN YEAR LIMITED WARRANTY KIDDE warrants that the enclosed alarm but not the battery will be free from defects in material and workmanship or design under normal use and service for a period of ten years from the date of purchase The obligation of KIDDE under this warranty is limited to repairing or replacing the alarm or any part which we find to be defective in material workmanship or design free of charge upon sending the alarm with proof of date of purchase postage and return postage prepaid to Warranty Service Department KIDDE 1016 Corporate Park Dr Mebane NC 27302 This
22. itors the air for the presence of CO It will alarm when there are high levels of CO present and when there are low levels of CO present over a longer period of time see page 21 for alarm times When a CO condition matches either of these situations the alarm voice message warning system will sound and be accompanied by the flashing red LED light The carbon monoxide sensor uses an electrochemical technology ZN CAUTION This alarm will only indicate the presence of carbon monoxide gas at the sensor Carbon monoxide gas may be present in other areas Individuals with medical problems may consider using warning devices which provide audible and visual signals for carbon monoxide concentrations under 30 ppm 2014 5 29 4 35 PM Installation Instructions Step 1 Installation Guide IMPORTANT THIS ALARM MUST BE MOUNTED ON A CEILING OR WALL IT WAS NOT DESIGNED FOR USE AS A TABLETOP DEVICE INSTALL ONLY AS DETAILED A Recommended Installation Locations Kidde Safety recommends the installation of a Smoke CO Alarm in the following locations For maximum protection we suggest an alarm be installed on each level of a multilevel home including every bedroom hallways finished attics and basements Put alarms at both ends of bedroom hallway or large room if hallway or room is more than 30 ft 9 1m long If you have only one alarm ensure it is placed in the hallway outside of he main sleeping area or in the main bedro
23. ks 2014 5 29 4 35 PM Warranty and Service Information The above warranty may not be altered except in writing signed by both parties hereto Your Kidde Combination Smoke amp CO Alarm is not a substitute or property fire disability life or other insurance of any kind Appropriate insurance coverage is your responsibility Consult your insurance agent Removal of the front cover will void the warranty This alarm is not intended to alert hearing impaired individuals During the specified warranty period Kidde Products will repair or replace at its discretion any defective Kidde Combination Smoke amp CO Alarms that are returned in a postage paid package to the following address Kidde Products Attn Warranty Returns 1016 Corporate Park Dr Mebane NC 27302 USA Please include your name address and phone number along with a brief description of what is wrong with the unit For further assistance please call our toll free Product Support Line at 1 800 880 6788 Damage from neglect abuse or failure to adhere to any of the enclosed instructions will result in termination of the warranty and the unit will not be replaced or repaired This user guide and the products described herein are copyrighted with all rights reserved Under these copyright laws no part of this user guide may be copied for use without the written consent of Kidde If you require further information please contact out Product Support Line at 1 800 88
24. lly see figure 2 NOT IN THIS AREA ANYWHERE AREA FIGURE 2 Mobile Homes Modern mobile homes have been designed and built to be energy efficient Install Smoke CO alarms as recommended above refer to Recommended Installation Instructions and figure 1 In older mobile homes that are not well insulated extreme heat or cold can be transferred from the outside to the inside through poorly insulated walls and roof This may cause a thermal barrier which can prevent smoke from reaching an alarm mounted on the ceiling In such mobile homes install your Smoke CO Alarm on an inside wall with the top edge of the alarm at a minimum of 4 inches 10cm and a maximum of 12 inches 30 5cm below the ceiling see figure 2 If you are not sure about the insulation in your mobile home or if you notice that the outer walls and ceiling are either hot or cold install your alarm on an inside wall ONLY 4 2014 5 29 4 35 PM Installation Instructions THIS EQUIPMENT SHOULD BE INSTALLED IN ACCORDANCE WITH THE NATIONAL FIRE PROTECTION ASSOCIATION S STANDARD 72 National Fire Protection Association Batterymarch Park Quincy MA 02269 WARNING This product is intended for use in ordinary indoor locations of family living units It is not designed to measure compliance with Occupational Safety and Health Administration OSHA commercial or industrial standards B Where Not to Install Do not install in gar
25. located too close to the cooking area Large quantities of combustible particles are generated from spills or when broiling Using the fan on a range hood which vents to the outside non recirculating type will also help remove these combustible products from the kitchen 5 2014 5 29 4 35 PM What Do If The Alarm Sounds If the alarm sounds check for fires first If a fire is discovered follow these steps Become thoroughly familiar with these items and review with all family members Alert small children in the home Leave immediately using one of your planned escape routes see page 26 Every second counts don t stop to get dressed or pick up valuables Before opening inside doors look for smoke seeping in around he edges and feel with the back of your hand If the door is hot use your second exit If you feel it s safe open the door very slowly and be prepared to close immediately if smoke and heat rush in e If the escape route requires you go through smoke crawl ow under the smoke where the air is clearer Go to your predetermined meeting place When two people have arrived one should leave to call 911 from a neighbor s home and the other should stay to perform a head count Do not reenter under any circumstance until fire officials give the go ahead There are situations where a smoke alarm may not be effective to protect against fire as stated in the NFPA Standard 72 For
26. ming fires sooner than photoelectric alarms Photoelectric sensing alarms may detect visible fire particles associated with slow smoldering fires sooner than ionization alarms Home fires develop in different ways and are often unpredictable For maximum protection Kidde recommends that both lonization and Photoelectric alarms be installed A battery powered alarm must have a battery of the specified type in good condition and installed properly Smoke alarms must be tested regularly to make sure the batteries and the alarm circuits are in good operating condition Smoke alarms cannot provide an alarm if smoke does not reach the alarm Therefore smoke alarms may not sense fires starting in chimneys walls on roofs on the other side of a closed door or on a different floor 4 2014 5 29 4 35 PM Features General Information If the alarm is located outside the bedroom or a different floor it may not wake up a sound sleeper The use of alcohol or drugs may also impair one s ability to hear the smoke alarm For maximum protection a smoke alarm should be installed in each sleeping area on every level of a home Although smoke alarms can help save lives by providing an early warning of a fire they are not a substitute for an insurance policy Home owners and renters should have adequate insurance to protect their lives and property Carbon Monoxide CO Alarm The Carbon Monoxide CO alarm mon
27. nect Feature Page 15 HUSH Control Page 15 16 Reset Feature tn even Page 16 Peak Level Page 16 LED Indicator Page 17 Tamper Resist Feature Page 17 18 What to do if the Alarm Sounds SMOKE 18 19 Carbon Monoxide Pages 20 Alarm Removal Battery Replacement Pages 21 22 General Alarm Maintenance Pages 23 24 End of Product Life Notification Page 23 Carbon Monoxide Safety Information General CO Information Page 24 Possible Sources 2255 25 yes te Page 24 CO Satety Tips ede mand Page 25 Symptoms of CO Poisoning Page 25 26 Fire Safety Information Escape Plan 26 Fire 27 Industry Safety Standards National Fire Protection Association Page 27 28 California State Fire Marshall Page 28 Consumer Product Safety Commission Page 28 NRG are ange Page 28 Limited Warranty and Service Information Pages 29 30 Product Registration Page 30 2014 5 29 4 35 PM In
28. ng cap in place to make certain that the red wire cannot contact any metal parts or the electrical box e When alarms are interconnected all interconnected units must be powered from a single circuit 11 4 2014 5 29 4 35 PM Installation Instructions e maximum of 24 Kidde Safety devices may be interconnected in a multiple station arrangement The interconnect system should not exceed the NFPA interconnect limit of 12 smoke alarms and or 18 alarms total smoke CO Smoke CO Combination heat etc This Smoke CO combination alarm must be counted as a smoke alarm when determining the number of units on an interconnect line With 18 alarms interconnected it is still possible to interconnect up to a total of 6 remote signaling devices and or relay modules see page 15 for details on interconnecting Kidde devices The maximum wire run distance between the first and last unit in an interconnected system is 1000 feet Figure 3 illustrates interconnection wiring Improper connection will result in damage to the alarm failure to operate or a shock hazard Make certain alarms are wired to a continuous non switched power line NOTE Use standard UL Listed household wire as required by local codes available at all electrical supply stores and most hardware stores FUSE OR CIRCUIT BREAKER BLACK RED CONNECTOR 5120 Optional Accessory FIGURE 3 Interconne
29. nit is in HUSH mode pushing the test reset button on the alarm will also end the HUSH period NOTE DENSE SMOKE WILL OVERRIDE THE HUSH CONTROL FEATURE AND SOUND A CONTINUOUS ALARM 15 4 2014 5 29 4 35 PM Operating Instructions CAUTION BEFORE USING THE ALARM HUSH FEATURE IDENTIFY THE SOURCE OF THE SMOKE AND BE CERTAIN A SAFE CONDITION EXISTS Reset Feature If the the Smoke CO Alarm is sounding a CO alarm pressing the test reset button will silence the alarm If the CO condition that caused the alert continues the alarm will reactivate within 200 seconds follow the action plan on page CO Peak Level Memory If the green LED is blinking once every 10 seconds the unit has detected a hazardous CO condition If the CO sensor has detected a CO level of 100 PPM or higher since last reset it will be recorded by the Peak Level Memory function To access the Peak Level Memory press the test reset button If a reading of 100 PPM or higher has been recorded the unit will announce Caution Carbon Monoxide Previously Detected If you ve been away from home this feature allows you to check if there was a CO reading of 100 or higher during your absence Pushing the test reset button resets the memory It s also reset when the power is removed Note the green LED blinking portion of CO Peak Level Memory is disabled when the unit is on battery power only LED Indicator Operation Red LED The red LED w
30. om Verify the alarm can be heard in all sleeping areas Locate an alarm in every room where someone sleeps with the door closed The closed door may prevent an alarm not located in that room from waking the sleeper Smoke heat and combustion products rise to the ceiling and spread horizontally ounting the alarm on the ceiling in the center of the room places it closest to all points in the room Ceiling mounting is preferred in ordinary residential construction When mounting an alarm on the ceiling ocate it at minimum bean of 4 10cm from the CEILING a side wall see figure If installing the alarm on the wall use an inside wall with the top edge of the alarm at a minimum of 4 10cm and a maximum of 12 30 5cm below ACCEPTABLE gt the ceiling see figure 1 FIGURE 1 2014 5 29 4 35 PM Installation Instructions Sloped Ceiling Installation The following information is from the National Fire Protection Association and is listed in Fire Code 72 Install Smoke Alarms on sloped peaked or cathedral ceilings at or within 3 ft 0 9m of the highest point measured horizontally NFPA 72 states Smoke alarms in rooms with ceiling slopes greater than 1 ft to 8 ft 3 m 2 4 m horizontally shall be located on the high side of the room NFPA 72 states A row of alarms shall be spaced and located within 3 ft 0 9 m of the peak of the ceiling measured horizonta
31. osure Unconsciousness convulsions cardiorespiratory failure death The above levels of exposure relate to healthy adults Levels differ for those at high risk Exposure to high levels of carbon monoxide can be fatal or cause permanent damage and disabilities Many cases of reported carbon monoxide poisoning indicate that while victims are aware they are not well they 4 25 2014 5 29 4 35 PM Carbon Monoxide Safety Information become so disoriented they are unable to save themselves by either exiting the building or calling for assistance Also young children and household pets may be the first effected Familiarization with the effects of each level is important Fire Safety Information Escape Plan Familiarize everyone with the sound of the smoke alarm and train them to leave the home when they hear it Practice a fire drill at least every six months including fire drills at night Ensure that small children hear the alarm and wake when it sounds They must wake up in order to execute the escape plan Practice allows all occupants to test your plan before an emergency You may not be able to reach your children It is important they know what to do Know two ways out of every room door amp window and identify a meeting place outside the home where everyone will gather once they have exited the residence When two people have reached the meeting place one should leave to call 911 while the second person s
32. rbon monoxide are present Powered by 120V AC 60 Hz 45mA max wire in connector and two AA battery backup Interconnectable to other Kidde Nighthawk brand smoke CO alarms see page 15 for details Alarm Voice message warning system that alerts you of the following conditions in the manner described below thus eliminating any confusion over which alarm is sounding FIRE The alarm voice pattern is three long alarm beeps followed by the verbal warning message FIRE This pattern is repeated until the smoke is eliminated The red LED light will flash while in alarm voice mode CARBON MONOXIDE The alarm voice pattern is four short alarm beeps followed by the verbal warning message WARNING CARBON MONOXIDE This continues until the unit is reset or the CO is eliminated While powered by battery only after four minutes the alarm voice pattern will sound once every minute The red Light Emitting Diode LED light will flash while in alarm voice mode LOW BATTERY When the batteries are low and need replacing the red LED light will flash and the unit will chirp one time followed by the warning message LOW BATTERY This cycle will occur once every minute and will continue for at least seven days Under battery power the LOW BATTERY voice only occurs once every 15 minutes Voice Message System that alerts user to the following conditions Only for smoke alarm Hush System announces HUSH
33. tays to account for additional family members Establish a rule that once you re out you never reenter under any circumstance Current studies have shown smoke alarms may not awaken all sleeping individuals and that it is the responsibility of individuals in the household that are capable of assisting others to provide assistance to those who may not be awakened by the alarm sound or to those who may be incapable of safely evacuating the area unassisted Fire Prevention Never smoke in bed or leave cooking food unattended Teach children never to play with matches or lighters Train everyone in the home to recognize the alarm pattern voice message warning and to leave the home using their escape plan when it s heard Know how to do Stop Drop and Roll if clothes catch on fire and how to crawl low under smoke Install and maintain fire extinguishers on every level of the home and in the kitchen basement and garage Know how to use a fire extinguisher prior to an emergency Second level and higher occupied rooms with windows should have an escape ladder 4 2014 5 29 4 35 PM Fire Safety Information Industry Safety Standards NFPA National Fire 19 Protection Association For your information the C 9 National Fire Protection 1 Association s Standard 72
34. troduction Thank you for purchasing the Kidde Combination Smoke and Carbon Monoxide Alarm model KN COSM IBA This alarm is suitable as a Single Station and or Multiple Station 24 devices alarm This alarm has a ten year limited warranty Please take a few minutes to thoroughly read this user guide and save for future reference Teach children how to respond to the alarms and that they should never play with the unit Your Kidde Smoke CO Alarm was designed to detect both smoke and carbon monoxide from any source of combustion in a residential environment It is not designed for use in a recreational vehicle RV or boat If you have any questions about the operation or installation of your alarm please call our toll free Product Support Line at 1 800 880 6788 The guide on Page 27 will help you determine the correct location of safety products that will help keep your home a safer place 2014 5 29 4 35 PM Product View RED AND GREEN LED Light Emitting Diode TEST RESET 52 T 3 C amp 5 PM I 2014 5 29 4 3 Product View TAMPER RESIST FEATURE AC CONNECTOR PINS 2014 5 29 4 35 PM Features Loud 85 decibel alarm Permanent independent smoke and carbon monoxide sensors Smoke alarm takes precedence when both smoke and ca
35. ur warranty Move the Smoke CO Alarm and place in another location prior to performing any of the following Staining or stripping wood floors or furniture Painting Wall papering Using adhesives Storing the unit in a plastic bag during any of the above projects will protect the sensors from damage Do not place near a diaper pail Z N WARNING Reinstall the Smoke CO Alarm as soon as possible to assure continuous protection When household cleaning supplies or similar contaminates are used the area must be well ventilated The following substances can effect the CO sensor and may cause false readings and damage to the sensor Methane propane iso butane iso propanol ethyl acetate hydrogen sulfide sulfide dioxides alcohol based products paints thinner solvents adhesives hair spray after shave perfume and some cleaning agents 23 1 2014 5 29 4 35 PM General Maintenance Carbon Monoxide Safety Information General CO Information Carbon monoxide CO is a colorless odorless and tasteless poison gas that can be fatal when inhaled CO inhibits the blood s capacity to carry oxygen Possible Sources CO can be produced when burning any fossil fuel gasoline propane natural gas oil and wood It can be produced by any fuel burning appliance that is malfunctioning improperly installed or not ventilated correctly Possible sources include furnaces gas ranges stoves gas clothes
36. y have a detrimental effect on the Smoke CO alarm A good safety measure is to replace the batteries twice a year at the same time A good safety measure is to replace the batteries twice a year at the same time you change your clocks for daylight saving time End of Life Notification Ten 10 years after unit is first powered this alarm will beep two times every 30 seconds to indicate it is time to replace the alarm REPLACE IMMEDIATELY IT WILL NOT DETECT CO IN THIS CONDITION End of Life Hush can be activated by pushing the test button to silence the End of Life chirp for approximately 3 days at a time for a maximum of 30 day life extension 22 2014 5 29 4 35 PM General Maintenance To keep your Smoke CO Alarm in good working order please follow these simple steps Verify the unit s alarm and LED lights operation by pushing the test reset button once a week Remove the unit from mounting bracket and vacuum the alarm cover and vents with a soft brush attachment once a month to remove dust and dirt REINSTALL IMMEDIATELY AFTER CLEANING AND THEN TEST USING THE TEST RESET BUTTON Never use detergents or other solvents to clean the unit Avoid spraying air fresheners hair spray or other aerosols near the Smoke CO Alarm Do not paint the unit Paint will seal the vents and interfere with the sensor s ability to detect smoke and CO Never attempt to disassemble the unit or clean inside This action will void yo