1. Rapid Entry Systems P N 10102664P1 Feb 2013 2013 Kidde All rights reserved Installation Instructions Introduction Your SupraSafe is the latest in Rapid Entry key control To fully utilize it s built in security features we recommend that reasonable care be given to the location and method of mounting The vault is coated with a tough baked polyurethane finish which is resistant to the harshest environmental abuse however it is always best to locate the vault in an area which is sheltered from excessive moisture and possible mechanical damage Important Contact your local fire department for specific mounting location and instructions Installation for Supra Max SupraSafe 1 SupraSafe 2HS 2HSR and Supra Safe 2HS TS Vault 1 Mount the vault so that the moisture drain hole is on the bottom 2 Use a level to plumb the vault square 3 Four 5 16 inch lag bolts have been provided for surface mounting the vault Important When installing the vault do not over tighten the four mounting bolts as this may distort the outside shell of the vault 4 To secure the vault to a masonry brick wall it is necessary to use the anchors provided with the 5 16 lag bolts mounting kit Drill a 1 2 hole approximately 1 3 4 deep into the masonry brick wall It is recommended to use a carbide masonry bit to prevent cracking or shattering Gently pound the anchor into the hole with a hammer so that it is flush with
2. are supplied for connection to tamper switch Tamper switch can be connected for either open or closed circuits Cast in Place Mounting Kit P N 454000 The Cast in Place Mounting kit is used only with the SupraSafe 2HSR and SupraSafe 2HSR TS vaults The kit contains a shell housing and mounting hardware to be cast in place in new masonry or concrete construction After construction is completed the vault mounts inside the recessed shell housing so that the small moisture drain hole is on the bottom Installation The mounting kit may be fastened to the inside wall of a concrete form or set in place during construction of a masonry wall Wiring conduit may be connected through one of several knockout holes in shell housing The orientation of the mounting kit requires that the rebar on the backplate be horizontal Mount the housing shell to the backplate so that the tamper switch adjustment screw is on the left side of the housing Important Care should be taken to insure that the front of the shell housing including the cover plate and screw heads is flush with finish wall Shell housing should be plumbed with a level Leave cover and screws in place until vault is ready to be mounted inside Four mounting studs are provided for securing the vault and chain lid assembly within the housing shell 1 Place vault in housing shell of mounting kit so that the vault s small moisture drain hole is on the bottom Align the tamper swit
3. ch of the vault with the tamper switch adjustment screw of the housing shell The tamper switch adjustment screw has a slotted head to adjust for proper switch operation 2 Install washers and nuts onto the two top mounting Tamper 2HSR TS 2HS TS only SupraSafe a 2HSR or 2HSR TS studs within the vault Do not over tighten mounting nuts as this may distort outside flange 3 Slip the chain mounting bracket attached to the chain lid assembly over the lower right hand stud prior to installing the bottom washers and nuts in the vault This will permanently attach the lid to the vault 4 Please contact your fire department to install the lid once the vault has been installed Figure 2 Cast in Place Mounting Kit and Side View of Installation lt pfpe_ i a aa Face plate Tamper switch adjusting screw Switch Vault Drain hole Adjusting Cast in Place screw tamper Mounting Kit switch
4. the wall Secure vault to the wall 5 Caulk between the vault and the wall for better waterproofing g Kidde A 6 Please contact your fire department to install the lid once the vault has been installed 7 We strongly recommend the wiring of the tamper switch be performed by a qualified alarm installer or licensed electrician The circuit shall conform to NEC class 2 or 3 or UL class 634 standards In no case shall the wiring supply more than 30 volts at 50 ma Consult local codes and ordinances prior to installations Figure 1 Side View of Mounted Vault SSS Sv LL SSS LLL VEN PA SES O HE a TSS EA CN F Drain hole hain mounting bracket Instructions for SupraSafe ZHSR and SupraSafe 2ZHSR TS Vaults The SupraSafe 2HSR and SupraSafe 2HSR TS vaults are designed to be recessed into a wall for attractive flush mounting These units can be adapted to fit a variety of hollow wall situations or can be installed in a sold concrete wall which has been cored to a six inch diameter For concrete or masonry walls in new construction we recommend the use of our Cast in Place Mounting Kit described below With the SupraSafe 2HSR TS removal of the tamper switch is not necessary during installation The alarm wiring to the tamper switch should be pulled tight so that any attempt to force the vault out of the wall will break the wire or pull terminals loose Push On type terminals
Download Pdf Manuals
Related Search
Related Contents
La culture en chantier Manual LedSBmanager2012e Volume 10 Issue 1 - Hogtown HomeGrown Hyperion 1300g Quick Start Guide in Spanish Copyright © All rights reserved.
Failed to retrieve file