Home
Kenmore gal.12-Year Installation Guide
Contents
1. P 21 SERVICE AND Fe B duiig M 22 Vent System INSPECHON testcase EEREREN 22 SIUE MoD CU Ol ERE m m 22 BINNS NS ro arro EE T 22 mois RHET P 23 Anode Rod INSPECCION soxsetesemenscuvPeuedEbn enia iiie e iiaia E ii E E UEM UM a egiii eraning 23 Temperature Pressure Relief Valve Operation ccccccccecccsececeeeeceeeecseeceseeeeseueeceeeseaeessaeessaeessaeeeseeeeseeeessaeeeseeeess 23 Bie T v 24 CS T osc vende uu u E M 24 rz uU ok CONS NR RR 25 TROUBEESEOOTINOXIUIDE erraren udi dut du onu REC ctas a Fic cnRetG A ener eee n ERU DRE SU reer ee EUN PUDE 25 Operational CCU ONS RE cm 26 Operational Conditions Continued aa octet sate cares TTE 27 TROUBLESHOOTING GUIDE CONTINUED eeeeeseennm nne 28 PART ORDER CI T 29 oe SISSY SI LISS SILI SI SS SI SISA SSSI SI SISA SI SISA SI SISA SI SISA SI SI SISA SA SI SI SI SIGS 2 NA 68 12 YEAR LIMITED WARRANTY ON WATER HEATER CS Q ONA a ve 69 For twelve years from the date of purchase if this water heater is installed and operated in a single family home in accordance with the 1 w
2. VENT GAS ODORS Downdraft Poor combustion 28 PARTS ORDER LIST KENMORE 12 YEAR GAS WATER HEATER MODEL NO S 153 331762 74 U S Gal 280 Liters BURNER ASSEMBLY MODEL NUMBER 153 331762 ANODE ROD 9001829 2 BURNER HEAD 9006200 2i BURNER ORIFICE 9003732 21 pS 4 6 O a 1 5 KEY NO PART DESCRIPTION 4 BURNER TUBE 9006199 DIP TUBE WITH INLET NIPPLE 9006214 7 9003737 9003738 9000058 9001584 9003736 9003735 186079 002 15 NPPLE HOTOUTLED 9003743 9004101 9006201 9003741 9003410 NOT SHOWN PILOT TUBE IS AN INTEGRAL PART OF THE PILOT ASSEMBLY 14 E 0 9003739 LM 1 1 1 1 1 1 1 Now that you have purchased your gas water heater should a need MODEL NUMBER ever exist for repair parts or service simply contact any Sears Service Center or call 1 800 4 MY HOME 1 800 469 4663 Be sure to SERIAL NUMBER provide all pertinent facts when you call or visit e TYPE GAS NATURAL OR PROPANE L P WHEN ORDERING REPAIR PARTS ALWAYS GIVE THE PART DESCRIPTION FOLLOWING INFORMATION THIS IS A REPAIR PARTS LIST NOT A PACKING LIST 29 30 31 Get it fixed at your home or ours Your Home For troubleshooting product manuals and expert advice amp managemylife www managemylife com For repair in your home of all major brand appliances lawn and garden equipment or heating and cooling systems no matter who made it no matte
3. This odor is derived from hydrogen sulfide gas dissolved in the water The smell is the result of four factors which must all be present for the odor to develop aconcentration of sulfate in the supply water e little or no dissolved oxygen in the water 26 a sulfate reducing bacteria within the water heater This harmless bacteria is non toxic to humans e an excess of active hydrogen in the tank This is caused by the corrosion protective action of the anode Smelly water may be eliminated or reduced in some water heater models by replacing the anode s with one of less active material and then chlorinating the water heater tank and all hot water lines Contact Sears Service for further information concerning an Anode Replacement and this Chlorination Treatment If the smelly water persists after the anode replacement and chlorination treatment we can only suggest that chlorination or aeration of the water supply be considered to eliminate the water problem Do not remove the anode leaving the tank unprotected By doing so all warranty on the water heater tank is voided AIR In Hot Water Faucets A WARNING e Flammable hydrogen gases may be present Keep all ignition sources away from faucet when turning on hot water HYDROGEN GAS Hydrogen gas can be produced in a hot water system that has not been used for a long period of time generally two weeks or more Hydrogen gas is extremely f
4. Water heated to a temperature which will satisfy space heating clothes washing dish washing cleaning and other sanitizing needs can scald and permanently injure you upon contact Some people are more likely to be permanently injured by hot water than others These include the elderly children the infirm or physically mentally handicapped If anyone using hot water in your home fits into one of these groups or if there is a local code or state law requiring a certain temperature water at the hot water tap then you must take special precautions In addition to using the lowest possible temperature setting that satisfies your hot water needs a means such as a mixing valve should be used at the hot water taps used by these people or at the water heater Mixing valves are available at plumbing supply or hardware stores see Figure 15 below Valves for reducing point of use temperature by mixing cold and hot water are also available Follow manufacturer s instructions for installation of the valves Before changing the factory setting on the thermostat read the Temperature Regulation section in this manual Sa A COLD WATER OUTLET Dun E E TEMPERED LHe WATER OUTLET 4 TO COLD WATER S INLET ON MIXING HOTWATER VATER HEATER VALVE OUTLET ON WATER HEATER FIGURE 15 A WARNING Do not connect to non potable water system Water supply systems may because of such events as high line pressure frequent cut offs or the
5. INLET AIR DUCT FIGURE 14 Louvers and Grilles In calculating free area consideration should be given to the blocking effect of louvers grilles or screens protecting openings Screens used should not be smaller than 1 4 inch 6 4 mm mesh If the free area through a design of louver or grille is known it should be used in calculating the size opening required to provide the free area specified If the design and free area is not known it may be assumed that wood louvers will be 20 25 percent free area and metal louvers and grilles will have 60 75 percent free area Louvers and grilles should be fixed in the open position or interlocked with the equipment so that they are opened automatically during equipment operation Special Conditions Created by Mechanical Exhausting or Fireplaces operation of exhaust fans ventilation systems clothes dryers or fireplaces may create conditions requiring special attention to avoid unsatisfactory operation of installed gas utilization equipment WATER PIPING Water temperature over 125 F 52 C can cause severe burns instantly resulting in severe injury or death Children elderly and the physically or mentally disabled are at highest risk for scald injury Feel water before bathing or showering Temperature limiting valves are available Read instruction manual for safe temperature setting A DANGER HOTTER WATER CAN SCALD Water heaters are intended to produce hot water
6. See Figure 9 and Figure 10 The confined space should be provided with two permanent openings communicating directly with an additional room s of sufficient volume so that the combined volume of all spaces meets the criteria for an unconfined space The total input of all gas utilization equipment installed in the combined space should be considered in making this determination Each opening should have a minimum free area of one square inch per 1 000 Btu per hour 22 cm kW of the total input rating of all gas utilization equipment in the confined space but not less than 100 square inches 645 cm One opening should commence within 12 inches 30 cm of the top and one commencing within 12 inches 30 cm of the bottom of the enclosures CHIMNEY OR GAS VENT OPENINGS FIGURE 10 B ALL AIR FROM OUTDOORS See Figures 9 11 12 and 13 The confined space should be provided with two permanent openings one commencing within 12 inches 30 cm of the top and one commencing within 12 inches 30 cm from the bottom of the enclosure The openings should communicate directly or by ducts with the outdoors or spaces crawl or attic that freely communicate with the outdoors CHIMNEY OR GAS VENT VENTILATION LOUVERS EACH END OF ATTIC Md OUTLET AIR jj WATER HEATER Mell FURNACE INLET AIR DUCT ALT INLET AIR VENTILATION LOUVERS FIGURE 11 e When directly communicating with the outdoors each op
7. WATER AND GAS CONNECTIONS CONNECTIONS BR 3 4 19 mm WIRE BRUSH OTE ub m lt ROLL OF LEAD FREE SOLDER GARDEN HOSE 6 FOOT TAPE PIPE WRENCH 1 2 13 mm WIRE BRUSH SOFT SOLDER FLUX TYPICAL INSTALLATION GET TO KNOW YOUR WATER HEATER GAS MODELS A Vent Pipe Ground Joint Union Q Temperature Pressure Relief Valve B Draft Hood J Sediment Trap R Rating Plate C Anode K Inner Door S Flue Baffle s D Tempered Hot Water Outlet L Outer door T Gas Control Valve Thermostat E Outlet M Untempered Hot Water Outlet optional U Drain Valve F Water Connections N Inlet Water Shut off Valve V Pilot and Main Burner G Gas Supply O Cold Water Inlet W Flue H Manual Gas Shut off Valve P Inlet Dip Tube X Metal Drain Pan ia A COLD WATER INLET INSTALL IN ACCORDANCE L 2 WITH LOCAL CODES y SEDIMENT TRAP AS i REQUIRED BY LOCAL TO VENT TERMINATION E CODES ON ROOF Nic oe ie A TO COLD WATER Wind INLET ON MIXING HOT WATER WATER HEATER VACUUM RELIEF VALVE OUTLET ON WATER HEATER O PREFERRED METHOD INSTALL PER T THERMOSTAT LOCAL CODES GAS CONTROL KNOB INSTALL THERMAL EXPANSION TANK OR DEVICE IF WATER HEATER IS IN A CLOSED WATER SYSTEM WATER TEMPERATURE ADJUSTING DIAL OFF a PILOT ON POSITION POSITION POSITION TOP VIEW V PILOT amp MAIN BURNER THERMOCOUPLE Pus BURNER TUBE MAIN BURNER ALL PIPING MATERIALS TO BE SUPPLIED BY CUSTOMERS CLOSED WATER SYSTEMS ARE TH
8. discharges periodically this may be due to thermal expansion You may have a check valve installed in the water line or a water meter with a check valve Consult the Sears Service Center for further information Do not plug the temperature pressure relief valve DRAINING e Hotwater discharge burn hazard A DANGER Keep clear of relief valve discharge unit Temperature limiting valves are available e Read instruction manual for safe temperature setting It is recommended that the tank be drained and flushed every 6 months to remove sediment which may build up during operation The water heater should be drained if being shut down during freezing temperatures To drain the tank perform the following steps 1 Turn off the gas to the water heater at the manual gas shut off valve 2 Openanearby hot water faucet until the water is no longer hot 3 Close the cold water inlet valve 4 Connect a hose to the drain valve and terminate it to an adequate drain or external to the building 24 5 Open the water heater drain valve and allow all of the water to drain from the tank Flush the tank with water as needed to remove sediment 6 Close the drain valve refill the tank and restart the heater as directed in this manual If the water heater is going to be shut down for an extended period the drain valve should be left open IMPORTANT Condensation may occur when refilling the tank and should not be confus
9. have required clearances between vent piping and combustible material will result in a fire hazard Be sure vent pipe is properly connected to prevent escape of dangerous flue gases which could cause deadly asphyxiation A WARNING Flue gases may escape if vent pipe is not connected Do not store corrosive chemicals in vicinity of water heater Chemical corrosion of flue and vent system can cause serious injury or death Contact a qualified installer or service agency Chemical vapor corrosion of the flue and vent system may occur if air for combustion contains certain chemical vapors Spray can propellants cleaning solvents refrigerator and air conditioner refrigerants swimming pool chemicals calcium and sodium chloride waxes bleach and process chemicals are typical compounds which are potentially corrosive GAS PIPING A WARNING Do not use water heater with any gas other than the gas shown on the rating plate Excessive pressure to gas control valve can cause serious injury or death e Turn off gas installation lines during e Contact qualified installer or service agency Make sure the gas supplied is the same type listed on the model rating plate The inlet gas pressure must not exceed 14 inch water column 3 5kPa for natural gas The minimum inlet gas pressure listed on the rating plate is for the purpose of input adjustment If the gas control valve is subjected to pressures exceeding 1 2 p
10. if you do not follow the safety message and how to avoid the risk of injury The California Safe Drinking Water and Toxic Enforcement Act requires the Governor of California to publish a list of substances known to the State of California to cause cancer birth defects or other reproductive harm and requires businesses to warn of potential exposure to such substances WARNING This product contains a chemical known to the State of California to cause cancer birth defects or other reproductive harm This appliance can cause low level exposure to some of the substances included in the act This product is certified to comply with a maximum weighted average of 0 25 lead content as required in some areas IMPORTANT DEFINITIONS e Qualified Technician A qualified technician must have ability equivalent to a licensed tradesman in the fields of plumbing air supply venting and gas supply including a thorough understanding of the requirements of the National Fuel Gas Code as it relates to the installation of gas fired water heaters The qualified technician must also be familiar with the design features and use of flammable vapor ignition resistant water heaters and have a thorough understanding of this instruction manual e Service Agency A service agency also must have ability equivalent to a licensed tradesman in the fields of plumbing air supply venting and gas supply including a thorough understanding of the requirements of the National Fue
11. in a bathtub or shower NOTE A water temperature range of 120 F 140 F 49 C 60 C is recommended by most residential dishwasher manufacturers 21 The thermostat of this water heater has been factory set at its lowest position PILOT LIGHTING It is adjustable and must be reset to the desired temperature setting to reduce the risk of scald injury The mark A indicative of approximately 120 F 49 C is preferred starting point Some states have a requirement for a lower setting Turn the water temperature dial clockwise CN to decrease the temperature or counterclockwise to increase the temperature Should overheating occur or the gas supply fail to shut off turn off the manual gas control valve to the appliance GAS CONTROL KNOB THERMOSTAT DIAL FIGURE 22 TIME FOR PERMANENT BURNS 2ND amp 3RD CE BURNS DEGREE MOST SEVERE BURNS TEMP 0 149 65 154 66 U S GOVERNMENT MEMORANDUM C P S C PETER L ARMSTRONG SEPT 15 1978 TIME FOR 1ST WATER DEGREE BURN TEMPERATURE F C 110 43 116 47 116 47 122 50 131 55 140 60 FIGURE 23 SERVICE AND ADJUSTMENT VENT SYSTEM INSPECTION At least once a year a visual inspection should be made of the venting system You should look for Obstructions which could cause improper venting The combustion and ventilation air flow must not be obstructed e Damage or deterioration which could cause im
12. leak amp Ne IAS e WARRANTY SERVICE KS mS C To obtain warranty service call 1 800 4 MY HOME 1 800 469 4663 Q PN uf A S0 This warranty applies only while this product is in use in the United States 6S This warranty gives you specific legal rights and you may also have other rights which vary from state to state GS oe Cw d e 66 SEARS BRANDS MANAGEMENT CORPORATION Hoffman Estates IL 60179 69 AS The price of your water heater does not include a free checkup service call On water heater installations arranged by Sears Sears warrants the installation A charge will be made on service calls due to poor or incomplete installation These include a Adjusting thermostat b Condensation c Leaks in pipes or fittings Master Protection Agreements Congratulations on making a smart purchase Your new Kenmore e 250 Food Loss Protection annually for any food spoilage product is designed and manufactured for years of dependable that is the result of mechanical failure of any covered operation But like all products it may require preventive refrigerator or freezer maintenance or repair from time to time That s when having a Master Protection Agreement can save you money and aggravation etal TENGUTS EMANE TERANO youncovarec prodtcliakes longer than promised The Master Protection Agreement also helps extend the life of your E i new product Here s what the Agreement includes 10 discount off the
13. not place chemical vapor emitting products near water heater uiid Pa mM n 268 Rm n re ee ate a a0 JE HE 9 o 4 eof ae ta A Fe a B o a GSE T ogaa T ew dapati of a SUV a AF ot gt 4 a Li ih Hug Ke E mn p T4 LU OR P Toa m ay E bi i a M A n ee BENE t bi amp on b Ua at ACE a Ya 1 a Breathing carbon monoxide can cause brain damage or death Always read and understand instruction manual A gas water heater cannot operate properly without the correct amount of air for combustion see Figure 9 Do not install in a confined area such as a closet unless you provide air as shown in the Combustion Air and Ventilation for Appliances Located in Confined Spaces section Never obstruct the flow of ventilation air If you have any doubts or questions at all call your gas supplier Failure to provide the proper amount of combustion air can result in a fire or explosion and cause death serious bodily injury or property damage 11 12 MAX 30 cm VENTILATION AIR OPENING 3 MIN 76 2 mm RECTANGULAR AIR DUCT AIR DUCT 12 MAX 30 cm FRONT VIEW OF DOOR FIGURE 9 If this water heater will be used in beauty shops barber shops cleaning establishments or self service laundries with dry cleaning equipment it is imperative that the water heater or water heaters be installed so that combustion and ventilation air be taken from ou
14. or frying noise Excessive condensation can cause pilot outage due to water running down the flue tube onto the main burner and putting out the pilot Because of the suddenness and amount of water condensation water may be diagnosed as a tank leak After the water in the tank warms up about 1 2 hours the condition should disappear Do not assume the water heater is leaking until there has been enough time for the water in the tank to warm up An undersized water heater will cause more condensation The water heater must be sized properly to meet the family s demands for hot water including dishwashers washing machines and shower heads Excessive condensation may be noticed during the winter and early spring months when incoming water temperatures are at their lowest Good venting is essential for a gas fired water heater to operate properly as well as to carry away products of combustion and water vapor Smoke Odor It is not uncommon to experience a small amount of smoke and odor during the initial start up This is due to burning off of oil from metal parts and will disappear in a short while OPERATIONAL CONDITIONS Smelly Odor In each water heater there is installed at least one anode rod see parts section for corrosion protection of the tank Certain water conditions will cause a reaction between this rod and the water The most common complaint associated with the anode rod is one of a rotten egg smell
15. unacceptable condition and must be corrected It is recommended that any devices installed which could create a closed system have a by pass and or the system have an expansion tank or device to relieve the pressure built by thermal expansion Thermal expansion tanks are available from Sears stores and through the Sears Service Centers Contact the local plumbing inspector water supplier and or the Sears Service Center for assistance in controlling these situations see Figure 26 and Figure 26 A WATER HEATER 3 COLD WATER PRESSURE INLET FITTING REDUCING VALVE WITH BY PASS vu StS INLET COLD WATER SHUT OFF 2 PRESSURE GAUGE RECOMMENDED INSTALLATION VERTICAL MOUNTING FIGURE 26 25 WATER HEATER COLD WATER INLET FITTING FLOOR CEILING JOIST ETC STRAPPING 3 PRESSURE REDUCING VALVE WITH 1 BY PASS EXPANSION ca TANK 2 P PRESSURE GAUGE INLET COLD WATER SHUT OFF ALTERNATE RECOMMENDED INSTALLATION HORIZONTAL MOUNTING FIGURE 26A Thermal Expansion Tank Specifications Tank Dimensions Capacity in Inches ip ans Venere Pipe Fitting On Tank Model Number eng NOTE Expansion tanks are pre charged with a 40 psi air charge If the inlet water pressure is higher than 40 psi the expansion tank s air pressure must be adjusted to match that pressure but must not be higher than 80 psi Strange Sounds Possible noises due to expansion and contractio
16. 80 MODEL NUMBER 153 331762 MATERIALS AND BASIC TOOLS NEEDED MATERIALS NEEDED To simplify the installation Sears has available the installation parts shown below You may or may not need all of these materials depending on your type of installation METAL DRAIN PANS AVAILABLE IN 20 508 mm DIAMETER FOR WATER HEATERS HAVING A DIAMETER 18 457 mm OR LESS 24 610mm DIAMETER FOR WATER HEATERS HAVING A DIAMETER 22 559 mm OR LESS AND AVAILABLE IN 28 711 mm DIAMETER FOR WATER HEATERS HAVING A DIAMETER 26 660 mm OR LESS EXPANSION TANKS FOR THERMAL EXPANSION CONDITIONS AVAILABLE IN 2 GALLONS 7 6 LITERS AND 5 GALLONS 18 9 LITERS CAPACITY THROUGH LOCAL SEARS STORE OR SERVICE CENTER BASIC TOOLS Additional Tools Needed You may or may not need all these tools depending on your When Sweat Soldering type of installation These tools can be purchased at your local Tubing Cutters or Hacksaw Sears Store Propane Torch e Soft Solder e Solder Flux Emery Cloth e Wire Brushes Pipe Wrenches 2 14 356 mm e Screwdriver e Tin Snips e 6 1 82 m Tape or Folding Ruler Garden Hose e Drill Pipe Dope or Teflon Tape PROPANE 3 C gt TUBING CUTTER TORCH SLOT HEAD SCREWDRIVER hj TIN SNIPS PHILLIPS SCREWDRIVER Pts aris Vin C HACKSAW EMERY CLOTH ROLL OF TEFLON PIPE DOPE TAPE USE ONLY ON SQUEEZE TUBE WATER HEATER USE FOR
17. E EE EEE EE emm T sey eree E i E E EE E E E E A E E EEEE T TYPICAL INSTALLA HON ceinaren AREE EEO NA E EAA a EEA pU ICM 8 INS TALBEATICN REQUIREMENTS 2 etosaimntudu nx enn i EE E EEEE AE tani HU Un IMG US 9 Removing the Old Water CALC us cies sattersiexsdsuiwmdeudistiarasddcaliasanad saves duuila mama S 29d da Sud Gen au eUuc duis nas a iniu dsc camsaieidadenbtanbens 9 Facts to Consider About the LOCAtION ccccccccesccccececcececcenecceneeseeecenceseueecsaeessaeessaeecsaeeesaueesaeeessaeeesueeesaeeesaueesaas 10 Ms lat n BIOS eno oio rie dioaiu eise mat darte aiotuo eU ne salsa LIN dU Sonti n iiai M a SiEUe eps amot e ovs ENEE E MUI NUT Cu EE USD 11 Closed System Thermal EXpanSloMireticcodctsusoaiantiesseacntiendoceanenadinvenatidicindauditdaedend Maud eub u eura Dd iu satanas Egal sai a 12 Combustion Air and Ventilation for Appliances Located in Unconfined Spaces seseeeeeeeene 12 Combustion Air and Ventilation for Appliances Located in Confined Spaces ccccccceecececeteseceeceeeeceeeeeneeaeeeees 12 VAT PIDIO REI 14 Temperature Pressure Relief Valve ccccccccccccssecceesceceececeeeeceaeecsaeecsaeecseeeesaeeesaeeeseeeeseaeeseaeeseaeeeseasesensessasesseeesseeeas 15 lu nemee m r A S 17 C adea e E mmt 18 Sediment Traps RRRPDRRCDRRERTRRRC 19 Erzageziuldrie cu
18. IONAL 3 MIN 76 2 mm FIGURE 21 GAS PIPING WITH ALL BLACK IRON PIPE TO GAS CONTROL 1 2 FOR YOUR SAFETY READ BEFORE LIGHTING WARNING f you do not follow these instructions exactly a fire or explosion may result causing property damage personal injury or loss of life FLAMMABLE BEFORE LIGHTING ENTIRE SYSTEM MUST BE FILLED WITH WATER AND AIR PURGED FROM ALL FAUCETS This appliance has a pilot which is lit by a piezo electric spark gas ignition system When lighting the pilot follow these instructions exactly BEFORE LIGHTING smell all around the appliance area for gas Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any electric switch do not use any phone in your building Immediately call your gas supplier from a neighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department C Use only your hand to push down or turn the gas control knob Never use tools If the knob will not push down or turn by hand don t try to repair it call a qualified service technician Force or attempted repair may result in a fire or explosion Do not use this appliance if any part has been under water Immediately contact a qualified installer or service agency to replace a flooded water heater Do not attempt to repair the un
19. OSE WITH BACK FLOW PREVENTION DEVICES INSTALLED IN THE INLET WATER SERVICE LINE nt ASSN FIGURE 1 8 Turn OFF the water supply to INSTALLATION REQUIREMENTS REMOVING THE OLD WATER HEATER FIGURE 2 Turn OFF the gas supply to the water heater If the main gas line Shut off valve serving all gas appliances is used also shut OFF the gas at each appliance Leave all gas appliances shut OFF until the water heater installation is completed see Figures 2 and 3 the water heater at the water shut off valve or water meter Some installations require that the water be turned off to the entire house see Figures 2 and 4 FIGURE 4 Check again to make sure the gas supply is OFF to the water heater Then disconnect the gas supply connection from the gas control valve ADANGER Burn hazard Hot water discharge Keep hands clear of drain valve discharge Attach a hose to the water heater drain valve and put the other end in a floor drain or outdoors Open the water heater drain valve Open a nearby hot water faucet which will relieve pressure in the water heater and speed draining The water passing out of the drain valve may be extremely hot To avoid being scalded make sure all connections are tight and that the water flow is directed away from any person see Figures 2 and 5 FIGURE 5 5 Disconnect the vent pipe from the draft hood where it c
20. OUSEKEEPING Vacuum around base of water heater for dust dirt and lint on a regular basis INSTALLED IN SUITABLE AREA To insure sufficient ventilation and combustion air supply proper clearances from the water heater must be maintained See Facts to Consider About the Location section Combustible materials such as clothing cleaning materials or flammable liquids etc must not be placed against or adjacent to the water heater because they could catch on fire A DANGER e Do not obstruct combustion air openings at the bottom of the water heater Do not use or store flammable vapor products such as gasoline solvents or adhesives in the same room or area near water heater or other appliance e Can cause serious death injury or ANODE ROD INSPECTION CAUTION Avoid water heater damage e Inspection and replacement of anode rod required The anode rod is used to protect the tank from corrosion Most hot water tanks are equipped with an anode rod The submerged rod deteriorates to protect the tank Instead of corroding the tank water ions attack and eat away the anode rod This does not affect the water s taste or color The rod must be maintained to keep the tank in operating condition Exposed Pitted Exposed Support Anode Support Wire Rod Wire FIGURE 25 Anode deterioration depends on water conductivity not necessar ily water condition A corroded or pitted anode rod indicates high wa
21. T WILL NOT LIGHT Thermocouple malfunction Replace pilot assembly and or thermocouple BURNER WILL NOT Thermocouple malfunction Replace pilot assembly and or thermocouple STAY LIT Defective Gas Control Replace Gas Control Dirty pilot burner Clean pilot assembly Thermocouple malfunction Replace pilot assembly and or thermocouple PILOT OUTAGE Thermocouple tip is not in contact with pilot flame Insert thermocouple correctly Defective Gas Control Replace Gas Control Heater not lit or thermostat not on Refer to LIGHTING INSTRUCTIONS Thermostat set too low Refer to TEMPERATURE REGULATION Heater undersized Reduce hot water use NOT ENOUGH HOT WATER Low gas pressure Contact your gas supplier Incoming water is unusually cold Allow more time for heater to re heat Leaking hot water pipes or fixtures Have plumber check and repair leaks High temperature limit switch activated Contact Sears Service to determine cause WATER TOO HOT Thermostat set too high Refer to TEMPERATURE REGULATION ATER HEATER SOUNDS Condensation dripping on burner Refer to CONDENSATION SIZZLING OR Sediment or calcium in bottom of heater tank Clean sediment from tank Refer to DRAINING RUMBLING instructions in Maintenance section of manual Improper combustion No adjustment available Contact Sears Service SOOTING l to determine cause Lack of supply air Improperly installed vent piping Contact Sears Service to determine cause
22. Use amp Care Guide Model No GAS FIRED SP UL Low Lead Content LISTED 153 331762 7A Gallon 280 Liter Kenmore Gas Water Heater For potable water heating only Not suitable for space heating Not for use in mobile homes INSTALLER Affix these instructions to or near the water heater WARNING If the information in these instructions is not followed exactly a fire or explosion may result causing property damage personal injury or death OWNER Retain these instructions for future reference FOR YOUR SAFETY An odorant is added to the gas used by this water heater Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance ADVERTENCIA WHAT TO DOIF YOU SMELL GAS Si no puede leer o entender el ingl s y necesita el manual de instrucciones en espa ol puede solicitarlo al 1 800 821 2017 NO TRATE DE INSTALAR U OPERAR ESTE CALENTADOR DE AGUA e Donottry to light any appliance SI NO ENTIENDE LAS INSTRUCCIONES No hacer caso de esta advertencia podr a originar lesiones graves o mortales e Do not touch any electrical switch do notuse any phone in your building P N 186079 002 0512 e Immediately call your gas supplier Sears Brands Management Corporation Hoffman Estates IL 60179 U S A ww w kenmore com www sears com from a neighbor s phone Follow the gas supplier s instructions e f you cannot reach your g
23. anual and safety messages before installing operating or servicing this water heater Failure to follow instructions and safety messages could result in death or serious injury Instruction Manual must remain with water heater Read this manual first Then before checking the water heater make sure the gas supply has been turned OFF and never turn the gas ON before the tank is completely full of water 27 TROUBLESHOOTING GUIDE CONTINUED These guidelines should be used by a qualified service agent Call Sears Service at 1 800 4 MY HOME 1 800 469 4663 for assistance Problem Solution Improperly sealed hot or cold supply connection Tighten threaded connections relief valve drain valve or thermostat threads Leakage from other appliances or water lines Inspect other appliances near water heater Condensation of flue products Refer to CONDENSATION Thermal expansion in closed water system Install thermal expansion tank DO NOT plug T amp P valve LEAKING T amp P VALVE Improperly seated valve Check relief valve for proper operation DO NOT plug T amp P valve High sulfate or mineral content in water supply Drain and flush heater thoroughly then refill SMELLY ODORS Bacteria in water supply Chlorinate or aerate water supply WATER LEAKS Gas control knob not positioned correctly Refer to LIGHTING INSTRUCTIONS Main gas supply off Turn on main gas shutoff valve PILO
24. as supplier call the fire department Installation and service must be performed by a qualified installer service agency or the gas supplier SAFE INSTALLATION USE AND SERVICE Your safety and the safety of others is extremely important in the installation use and servicing of this water heater Many safety related messages and instructions have been provided in this manual and on your own water heater to warn you and others of a potential injury hazard Read and obey all safety messages and instructions throughout this manual It is very important that the meaning of each safety message is understood by you and others who install use or service this water heater This is the safety alert symbol It is used to alert you to potential personal injury hazards Obey all safety messages that follow this symbol to avoid possible injury or death DANGER indicates an imminently hazardous situation which if not avoided will result A DANGER in injury or death WARNING indicates a potentially hazardous situation which if not avoided could result A WARNING in injury or death CAUTION indicates a potentially hazardous situation which if not avoided could result A CAUTION in minor or moderate injury CAUTION CAUTION used without the safety alert symbol indicates a potentially hazardous situation which if not avoided could result in property damage All safety messages will generally tell you about the type of hazard what can happen
25. ater heater follow the draining instructions in this manual and replace the Temperature Pressure Relief Valve with a properly rated sized new one Note The purpose of a Temperature Pressure Relief Valve is to prevent excessive temperatures and pressures in the storage tank The T amp P valve is not intended for the constant relief of thermal expansion A properly sized thermal expansion tank must be installed on all closed systems to control thermal expansion see Closed Water Systems and Thermal Expansion on page 23 If you do not understand these instructions or have any questions regarding the Temperature Pressure Relief Valve call the toll free number listed on the back cover of this manual for technical assistance Filling the Water Heater CAUTION Avoid water heater damage Fill tank with water before operating Never use this water heater unless it is completely full of water To prevent damage to the tank the tank must be filled with water Water must flow from the hot water faucet before turning ON gas to the water heater To fill the water heater with water Close the water heater drain valve by turning the handle to the right clockwise The drain valve is on the lower front of the water heater Open the cold water supply valve to the water heater NOTE The cold water supply valve must be left open when the water heater is in use To insure complete filling of the tank allow air to exit by open
26. ater on and safety messages could result in carpeted floor Gest A Do not operate water heater if This manual must remain with water flood damaged heater VNB N e E Water temperature over 125 F A WARNING 52 C can cause severe burns JQ instantly resulting in severe injury LZ or death a Overheated water can cause Children the elderly and the S VAE ACREA AESI physically or mentally disabled N are at highest risk for scald injury LC SOS Properly sized temperature and pressure relief valve must Feel water before bathing or be installed in opening showering provided Temperature limiting valves are available Read this instruction manual for safe temperature setting A WA RN N G A WA RN N G Eden system in accordance with Fire or Explosion Hazard Do not operate water heater if flood damaged Avoid all ignition sources if you smell gas Do not expose water heater control to excessive gas if a standard model is installed above ihe 7 700 ft 2347m Use only gas shown on rating plate AVIPDA TROU Maintain required clearances to combustibles d juu Donot operate if soot buildup is present Keep ignition sources away from faucets after ii Qa Menges period of non use High altitude orifice must be installed Do not obstruct water heater air intake with insulating jacket Read instruction manual before ib Do not place chemical vapor emitting installing using or s
27. during any pressure testing of the gas supply piping system at test pressures equal to or less than 1 2 pound per square inch 3 5 kPa Connecting the gas piping to the gas control valve of the water heater can be accomplished by either of the two methods shown in Figures 20 and 21 SEDIMENT TRAPS A WARNING e Contaminates in gas lines can cause fire or explosion e Clean all before installation gas piping e Install sediment trap in accordance with NFPA54 Contaminants in the gas lines may cause improper operation of the gas control valve that may result in fire or explosion Before attaching the gas line be sure that all gas pipe is clean on the inside To trap any dirt or foreign material in the gas supply line a sediment trap must be incorporated in the piping The sediment trap must be readily accessible Install in accordance with the Gas Piping section Refer to the current edition of the National Fuel Gas Code ANSI Z223 1 NFPA 54 A sediment trap should be installed as close to the inlet of the water heater as practical at the time of water heater installation The sediment trap should be either a tee fitting with a capped nipple in the bottom outlet or other device recognized as an effective sediment trap If a tee fitting is used it should be installed in conformance with one of the methods of installation shown in Figures 20 and 21 GROUND JOINT UNION OPTIONAL GAS CONTROL GROUND JOINT UNION OPT
28. ed with a tank leak SERVICE Before calling for repair service read the Start Up Conditions and Operational Conditions found in the Troubleshooting Guide of this manual If a condition persists or you are uncertain about the operation of the water heater let the Sears Service Center check it out Contact Sears Service Center at 1 800 4 MY HOME 1 800 469 4663 TROUBLESHOOTING GUIDE START UP CONDITIONS Thermal Expansion CAUTION Avoid water heater damage Install thermal expansion tank or device if necessary Contact qualified installer or service agency Water supply system may because of such events as high line pressure frequent cut offs and the effects of water hammer have installed devices such as pressure reducing valves check valves back flow preventers etc to control these types of problems When these devices are not equipped with an internal by pass and no other measures are taken the devices cause the water system to be closed As water is heated it expands thermal expansion and closed systems do not allow for the expansion of heated water The water within the water heater tank expands as it is heated and increases the pressure of the water system If the relieving point of water heater s temperature pressure relief valve is reached the valve will relieve the excess pressure The temperature pressure relief valve is not intended for the constant relief of thermal expansion This is an
29. effects of water hammer among others have installed devices such as pressure reducing valves check valves back flow preventers etc to control these types of problems When these devices are not equipped with an internal by pass and no other measures are taken the devices cause the water system to be closed As water is heated it expands thermal expansion and closed systems do not allow for the expansion of heated water The water within the water heater tank expands as it is heated and increases the pressure of the water system If the relieving point of the water heater s temperature pressure relief valve is reached the valve will relieve the excess pressure The temperature pressure relief valve is not intended for the constant relief of thermal expansion This is an unacceptable condition and must be corrected It is recommended that any devices installed which could create a closed system have a by pass and or the system have an expansion tank to relieve the pressure built by thermal expansion in the water system Refer to the Thermal Expansion section under Troubleshooting Guide or contact local plumbing authority or local Sears Service Center on how to control this situation NOTE To protect against untimely corrosion of hot and cold water fittings it is strongly recommended that di electric unions or couplings be installed on this water heater when connected to copper pipe CAUTION Avoid water heater damage Insta
30. ening should have a minimum free area of 1 square inch per 4 000 Btu per hour 5 5 cm kW of total input rating of all equipment in the enclosure see Figure 12 s CHIMNEY OR GAS VENT VENTILATION LOUVERS mS EACH END OF ATTIC Jj INLET AIR DUCT ENDS 1 OR 30 cm ABOVE FLOOR FIGURE 12 When communicating with the outdoors through vertical ducts each opening should have a minimum free area of 1 square inch per 4 000 BTU per hour 5 5 cm kW of total input rating of all equipment in the enclosure see Figure 12 on page 11 When communicating with the outdoors through horizontal ducts each opening should have a minimum free area of 1 square inch per 2 000 BTU per hour 11 cm kW of total input rating of all equipment in the enclosure see Figure 14 Alternatively a single permanent opening may be used when communicating directly with the outdoors or with spaces that freely communicate with the outdoors The opening should have a minimum free area of 1 square inch per 3 000 BTU per hour 8 3 cm kW of total input rating of all equipment in enclosure See Figure 13 ALTERNATE OPENING LOCATION FIGURE 13 When ducts are used they should be of the same cross sectional area as the free area of the openings to which they connect The minimum short side dimension of rectangular air ducts should not be less than 3 inches 76 2 mm see Figure 14 jys CHIMNEY OR GAS VENT TIT l N LS ey
31. ervicing vias products near water heater water heater e Gas and carbon monoxide detectors are available Breathing carbon monoxide can cause brain damage or death Always read and understand instruction manual A DANGER CAUTION Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other Improper installation and use may result appliance in property damage Do not operate water heater if flood damaged Inspect and replace anode e Install in location with drainage Fill tank with water before operation Be alert for thermal expansion Refer to this manual for installation and service TABLE OF CONTENTS SAFE INSTALLATION USE AND SERVIGE tas stcksud s utin ka nada surpris Caelo aa d dados i cir 2 SAPEI PRECAUTIONS seriesas E 2 oy a cold dioe PONI T 3 TABLE OF CONTE NT eneo ee ene eee ee ert ene ne ene een eee ee ee eee eee ee 4 OU esL ID 5 CUSTOMER TISESPONSIBIETTIESS arrrsreirtemcu daturi isa aq eura hei Rebate GR EEDEN EA EEAO RENESSE EERIE URNE DEDE 6 PRODUCT SPEGIFIGATIOBS i nisuinerimitenszebaticettuurxaedeniptt madida td uates watetsdicas ante cicer mah elata dad Rd data 6 MATERIALS AND BASIC TOOLS NEEDEDL etritdate Ehntnaduievua atta sd eda razk kl rtrt eid a dg xr sias idus ache adimi T Matora Needed NETTE ET IEEE E
32. es Owners manual instructions and all local applicable plumbing codes Sears will NYA e c Oy wy Se 1 Supply free water heater parts for those that are defective in material or workmanship e Q 2 Supply a free water heater for one that develops a tank leak See notes below also Q AN AS Q For the second through twelfth year from the purchase date you must pay the labor cost for installation of parts or water heater Q o MM a e PX Forcommercial institutional industrial or residential use by two or more families the above limited warranty is only for two years During Co K the second year you must pay the labor cost for parts or water heater installation OOK 9 If governmental regulations prohibit Sears from furnishing a comparable model replacement water heater under this warranty Sears will Q K furnish a new water heater of comparable output as permitted by such governmental regulations however the Owner will be charged Q A for the additional cost associated with the changes made to comply with such governmental regulations e Replacements furnished under this warranty do not carry a new warranty and are only covered by the unexpired portion of the original e 9 warranty v e we Ko 1 YEAR EXCLUSIVE KENMORE LABOR WARRANTY Q e Gs K For the first year from the date of purchase Sears will free of charge supply and install new water heater parts for defective ones or a Ka new water heater for one that develops a
33. es in humid weather or pipe connections may be leaking C The anode rod fitting may be leaking D Small amounts of water from temperature pressure relief valve may be due to thermal expansion or high water pressure in your area E The temperature pressure relief valve may be leaking at the tank fitting F Water from a drain valve may be due to the valve being slightly opened G The drain valve may be leaking at the tank fitting H Combustion products contain water vapor which can condense on the cooler surfaces of the tank Droplets form and drip onto the burner or run on the floor This is common at the time of start up after installation and when incoming water is cold l Water in the water heater bottom or on the floor may be from condensation loose connections or the relief valve DO NOT replace the water heater until a full inspection of all possible water sources is made and necessary corrective steps taken Leakage from other appliances water lines or ground seepage should also be checked To check where threaded portion enters tank insert cotton swab between jacket opening and fitting If cotton is wet follow Draining instructions in the Service and Adjustment section and then remove fitting Put pipe dope or teflon tape on the FIGURE 27 threads and replace Then follow Filling the Water Heater instructions in the nstallation Instructions section AWARNING Read and understand instruction m
34. fects of thermal expansion Thermal expansion tanks are available from Sears stores and through the Sears Service Centers Contact the local plumbing inspector water supplier and or the Sears Service Center for assistance in controlling these situations For additional information see the Troubleshooting Guide later thermal expansion COMBUSTION AIR AND VENTILATION FOR APPLIANCES LOCATED IN UNCONFINED SPACES UNCONFINED SPACE is space whose volume is not less than 50 cubic feet per 1 000 Btu per hour 4 8 m per kW of the aggregate input rating of all appliances installed in that space Rooms communicating directly with the space in which the appliances are installed through openings not furnished with doors are considered a part of the unconfined space In unconfined spaces in buildings infiltration may be adequate to provide air for combustion ventilation and dilution of flue gases However in buildings of tight construction for example weather stripping heavily insulated caulked vapor barrier etc additional air may need to be provided using the methods described in Combustion Air and Ventilation for Appliances Located in Confined Spaces COMBUSTION AIR AND VENTILATION FOR APPLIANCES LOCATED IN CONFINED SPACES CONFINED SPACE is a space whose volume is less than 50 cubic feet per 1 000 Btu per hour 4 8 m per kW of the aggregate input rating of all appliances installed in that space A ALL AIR FROM INSIDE BUILDINGS
35. g in severe injury or death Children the elderly and the physically or mentally disabled are at highest risk for scald injury Feel water before bathing or showering Temperature limiting valves are available Read this instruction manual for safe temperature setting HOTTER WATER CAN SCALD Water heaters are intended to produce hot water Water heated to a temperature which will satisfy space heating clothes washing dish washing and other sanitizing needs can scald and permanently injure you upon contact Some people are more likely to be permanently injured by hot water than others These include the elderly children the infirm or physically mentally handicapped f anyone using hot water in your home fits into one of these groups or if there is a local code or state law requiring a certain temperature water at the hot water tap then you must take special precautions In addition to using the lowest possible temperature setting that satisfies your hot water needs a means such as a mixing valve should be used at the hot water taps used by these people or at the water heater Mixing valves are available at plumbing supply or hardware stores Follow manufacturer s instructions for installation of the valves Before changing the factory setting on the thermostat see Figures 22 and 23 Never allow small children to use a hot water tap or to draw their own bath water Never leave a child or handicapped person unattended
36. ied draft hood brackets Place the vent pipe over the draft hood With the vent pipe in position drill a small hole through both the vent pipe and draft hood Secure them together with a sheet metal screw see Figure 18 DRAFT HOOD v VENT v S SCREW DRAFT HOOD See pes E DRAFT HOOD 4 VENT TO OUTDOORS OR CHIMNEY BRACKET 7 e v SCREW l FIGURE 18 Obstructed or deteriorated vent systems may present serious health risk or asphyxiation The vent pipe from the water heater must be no less than the diameter of the draft hood outlet on the water heater and must slope upward at least 1 4 inch per linear foot 21 mm per meter see Figure 19 TO CHIMNEY MIN 1 4 INCH RISE PER LINEAR FOOT 21 mm PER METER FIGURE 19 All vent gases must be completely vented to the outdoors of the structure dwelling Install only the draft hood provided with the new water heater and no other draft hood Vent pipes must be secured at each joint with sheet metal screws There must be a minimum of 6 inches 153 mm clearance between single wall vent pipe and any combustible material Fill and seal any clearance between single wall vent pipe and combustible material with mortar mix cement or other noncombustible substance For other than single wall follow vent pipe manufacturer s clearance specifications To insure a tight fit of the vent pipe in a brick chimney seal around the vent pipe with mortar mix cement Failure to
37. ing the nearest hot water faucet Allow water to run until a constant flow is obtained This will let air out of the water heater and the piping Check all water piping and connections for leaks Repair as needed VENTING A WARNING e Vent dampers must be certified in accordance with ANSI Z21 66 CSA 6 14 e Vent damper must permit proper drafting of water heater e Install properly sized venting e Do not install without venting outdoors Donotinstall without drafthood f common vented install in accordance with NFPA 54 Be alert for obstructed or deteriorated vent system to avoid serious injury or death Breathing carbon monoxide can cause brain damage or death Always read and understand instruction manual VENT DAMPERS Any vent damper whether it is operated thermally or otherwise must be removed if its use inhibits proper drafting of the water heater Thermally Operated Vent Dampers This gas fired water heater has a thermal efficiency at or above 80 which may produce a relatively low flue gas temperature Such temperatures may not be high enough to properly open thermally operated vent dampers This would cause spillage of the flue gases and may cause carbon monoxide poisoning Vent dampers must bear evidence of certification as complying with the current edition of the American National Standard ANSI Z21 66 CGA 6 14 cover electrically and mechanically actuated vent dampers Before installation of an
38. isting piping NOTE This water heater is super insulated to minimize heat loss from the tank Further reduction in heat loss can be accomplished by insulating the hot water lines from the water heater TEMPERATURE PRESSURE RELIEF VALVE A WARNING Temperature pressure relief valve must comply with ANSI A21 22 CSA 4 4 and ASME code Properly sized temperature relief valve must be installed in opening provided e Can result in overheating and excessive tank pressure e Can cause serious injury or death This heater is provided with a properly certified combination temperature pressure relief valve by the manufacturer The valve is certified by a nationally recognized testing laboratory that maintains periodic inspection of production of listed equipment of materials as meeting the requirements for Relief Valves for Hot Water Supply Systems ANSI 221 22 CSA 4 4 and the code requirements of ASME If replaced the valve must meet the requirements of local codes but not less than a combination temperature and pressure relief valve certified as indicated in the above paragraph The valve must be marked with a maximum set pressure not to exceed the marked hydrostatic working pressure of the water heater 150 psi 1 035kPa and a discharge capacity not less than the water heater input rate as shown on the model rating plate For safe operation of the water heater the relief valve must not be removed from it
39. it It must be replaced LIGHTING INSTRUCTIONS M THERMOCOUPLE BURNER FIGURE A FIGURE B FIGURE C gm IGNITOR GENERATOR THERMOSTAT MAIN BURNER QW OFF POSITION PILOT POSITION ON POSITION l GAS CONTROL TOP VIEW FIGURE D above on this label Set the thermostat to the lowest setting by turning thermostat dial fully clockwise X until it stops Push the gas control knob down slightly and turn ORA Read the safety information clockwise X to OFF see Figure A NOTE Knob cannot be turned from PILOT to OFF unless knob is pushed down slightly Do not force 4 B Remove the inner and outer burner doors located below and behind the gas control unit Wait five 5 minutes to clear out any gas If you then smell gas SIOP Follow B in the safety information bove on this label If you don t smell gas go to next step his unit is equipped with a push button pilot ignitor which is used to light the pilot Locate the ignitor on the gas control Turn gas control knob counterclockwise to PILOT see Figure B The pilot is located on the right side of the burner It can be located by looking through the burner opening in the jacket while pressing the piezo ignitor button several times Look for a spark at the pilot location see Figure D Once the pilot has been found push the gas knob all the way down Immediately press the pilot ignitor button rapidl
40. ith the Facts to Consider About the Location section in this manual For California installation this water heater must be braced anchored or strapped to avoid falling or moving during an earthquake See instructions for correct installation procedures Instructions may be obtained from California s Office of the State Architect 1102 Q Street Suite 5100 Sacramento CA 95811 Instructions can also be downloaded to your computer at www dsa dgs ca gov Pubs Massachusetts Code requires this water heater to be installed in accordance with Massachusetts 248 CMR 2 00 State Plumbing Code and 248 CMR 5 00 WARNING Use two or more people to move and install the water heater Failure to do so can result in injury including back injury IMPORTANT Do not remove any permanent instructions labels or the data label from either the outside of the water heater or on the inside of water heater panels e Remove exterior packaging and place installation components aside Inspect all parts for damage prior to installation and start up Completely read all instructions before attempting to assemble and install this product e After installation dispose of recycle all packaging materials PRODUCT SPECIFICATIONS MINIMUM VENT PIPE DIAMETER INCHES INCHES HEIGHT TO mm mm JACKET TOP 4 102 RECOVERY RATE GALS PER HOUR 90 F RISE TITTARE DIMENSIONS TANK IN INCHES mm CAPACITY IN GALS LTRS 74 2
41. l Gas Code as it relates to the installation of gas fired water heaters The service agency must also have a thorough understanding of this instruction manual and be able to perform repairs strictly in accordance with the service guidelines provided by the manufacturer e Gas Supplier The natural gas or propane utility or service who supplies gas for utilization by the gas burning appliances within this application The gas supplier typically has responsibility for the inspection and code approval of gas piping up to and including the natural gas meter or propane storage tank of a building Many gas suppliers also offer service and inspection of appliances within the building AWARNING FIRE AND EXPLOSION HAZARD Can result in serious injury or death Nha j Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance Storage of or use of gasoline or other flammable vapors or liquids in the Flammable Vapors vicinity of this or any other appliance can result in serious injury or death Read and follow water heater warnings and instructions Sears Brands Management Corporation SAFETY PRECAUTIONS AWARNING Read and understand this instruction manual and safety messages before installing operating or servicing this water heater Failure to follow these instructions A WARNING Fire Hazard For continued protection against risk of fire Do not install water he
42. lammable and explosive To prevent the possibility of injury under these conditions we recommend the hot water faucet located farthest away be opened for several minutes before any electrical appliances which are connected to the hot water system are used such as a dishwasher or washing machine If hydrogen gas is present there will probably be an unusual sound similar to air escaping through the pipe as the hot water faucet is opened There must be no smoking or open flame near the faucet at the time it is open High Temperature Shut Off System This water heater is equipped with an automatic gas shutoff system This system shuts off the gas supply to the water heater burner when high water temperatures are present It is non resettable If the high temperature shut off activates the gas control valve must be replaced If this were to occur turn OFF the entire gas supply to the water heater Contact the Sears Service Center OPERATIONAL CONDITIONS CONTINUED Never use this water heater unless it is completely filled with EV UI i L 1LLLLu water To prevent damage to the tank the tank must be filled l with water Water must flow from the hot water faucet before Leakage Checkpoints turning ON gas to the water heater see Figure 27 A Water at the draft hood is water vapor which has condensed out of the combustion products This is caused by a problem in the vent Contact the gas utility B Condensation may be seen on pip
43. ll thermal expansion tank if necessary Do not apply heat to cold water inlet Contact qualified installer or Sears Service Center Figure 16 shows the typical attachment of the water piping to the water heater The 74 gallon model water heater is equipped with 1 NPT water connections TYPICAL INSTALLATION SHUTOFF VALVE HOT WATER COLD WATER OUTLET INLET n 4 u zur FEMALE THREADED TO SWEAT COUPLING D BD INSTALLED INSTALLED THREADED 3 CX THREADED NIPPLE NIPPLE DRAFT HOOD TEMPERATURE PRESSURE RELIEF VALVE DISCHARGE PIPE Do not cap or plug FIGURE 16 NOTE If using copper tubing solder tubing to an adapter before attaching the adapter to the water connections Do not solder the water lines directly to the water connections on the tank It will harm the dip tube and damage the tank e Look at the top cover of the water heater The water outlet is marked HOT Put two or three turns of teflon tape around the exposed end of the NPT threaded nipple Connect the hot water pipe to the hot water outlet on the water heater Please note that adapters may be needed to match existing piping Look at the top of the water heater The cold water inlet is marked COLD Put two or three turns of teflon tape around the exposed end of the NPT threaded nipple Connect the cold water pipe to the cold water inlet of the water heater Please note that adapters may be needed to match ex
44. n of some metal parts during periods of heat up and cool down do not represent harmful or dangerous conditions Condensation causes sizzling and popping within the burner area during heating and cooling periods and should be considered normal See Condensation section Draft Hood Operation Check draft hood operation by performing a worst case depressurization of the building With all doors and windows closed and with all air handling equipment and exhaust fans Operating such as furnaces clothes dryers range hoods and bathroom fans a match flame should still be drawn into the draft hood of the water heater with its burner firing If the flame is not drawn toward the draft hood shut off water heater and make necessary air supply changes to correct Condensation Whenever the water heater is filled with cold water some condensate will form while the burner is on A water heater may appear to be leaking when in fact the water is condensation This usually happens when e Anew water heater is filled with cold water for the first time Burning gas produces water vapor in water heaters particularly high efficiency models where flue temperatures are lower e Large amounts of hot water are used in a short time and the refill water in the tank is very cold Moisture from the products of combustion condense on the cooler tank surfaces and form drops of water which may fall onto the burner or other hot surfaces to produce a sizzling
45. nual have been tested and approved for installation at elevations up to 7 700 feet 2 347 m above sea level For installation above 7 700 feet 2 347 m the water heater s Btu input should be reduced at the rate of 4 percent for each 1 000 feet 305 m above sea level which requires replacement of the burner orifice in accordance with the National Fuel Gas Code ANSI Z223 1 NFPA 54 Contact your local gas supplier for further information Failure to replace the standard orifice with the proper high altitude orifice when installed at elevations above 7 700 feet 2 347 m could result in improper and inefficient operation of the appliance producing carbon monoxide gas in excess of the safe limits This could result in serious injury or death Contact your local gas supplier for any specific changes that may be required in your area A WARNING Use joint compound or tape compatible with propane e Leak test before operating heater e Disconnect gas piping and shut off valve before pressure testing system The water heater and its gas connection must be leak tested before placing the water heater in operation The water heater and its individual shut off valve should be disconnected from the gas supply piping system during any pressure testing of that system at test pressures in excess of 1 2 pound per square inch 3 5 kPa It should be isolated from the gas supply piping system by closing its individual manual shut off valve
46. of time a flooded water heater will create dangerous conditions which can cause DEATH SERIOUS BODILY INJURY OR PROPERTY DAMAGE Contact a Sears Service Center to replace a flooded water heater Do not attempt to repair the unit It must be replaced At least once a year a visual inspection should be made of the main burner and pilot burner see Figure 24 You should check for sooting Soot is not normal and will impair proper combustion Soot build up indicates a problem that requires correction before further use Turn OFF gas to water heater and leave off until repairs are made because failure to correct the cause of the sooting can result in a fire causing death serious injury or property damage BURNER TUBE PILOT TUBING FIGURE 24 BURNER CLEANING In the event your burner needs cleaning following these instructions If inspection of the burner shows that cleaning is required turn the gas control knob clockwise CN to the OFF position depressing slightly NOTE The knob cannot be turned from PILOT to OFF unless knob is depressed slightly DO NOT FORCE Loose deposits on or around the burner can be removed by carefully using the hose of a vacuum cleaner inserted through the access door of the water heater If the burner needs to be removed for additional cleaning call the Sears Service Center to remove and clean the burner and correct the problem that required the burner to be cleaned H
47. on to the top of the water heater as this will interfere with safe operation of the draft hood Do not cover the outer door thermostat or temperature amp pressure relief valve Donotallow insulation to come within 2 50 8 mm of the floor to prevent blockage of combustion air flow to the burner Do not cover the instruction manual Keep it on the side of the water heater or nearby for future reference Doobtain new warning and instruction labels from Sears for placement on the blanket directly over the existing labels Do inspect the insulation blanket frequently to make certain it does not sag thereby obstructing combustion air flow CLOSED SYSTEM THERMAL EXPANSION As water is heated it expands thermal expansion In a closed system the volume of water will grow As the volume of water grows there will be a corresponding increase in water pressure due to thermal expansion Thermal expansion can cause premature tank failure leakage This type of failure is not covered under the limited warranty Thermal expansion can also cause intermittent temperature pressure relief valve operation water discharged from the valve due to excessive pressure build up The temperature pressure relief valve is not intended for the constant relief of thermal expansion This condition is not covered under the limited warranty A properly sized thermal expansion tank should be installed on all closed systems to control the harmful ef
48. onnects to the water heater In most installations the vent pipe can be lifted off after any screw or other attached devices are removed Dispose of the draft hood The new water heater has a draft hood which must be used for proper operation If you have copper piping to the water heater the two copper water pipes can be cut with a hacksaw approximately four inches away from where they connect to the water heater see Figure 6 This will avoid cutting off pipes too short Additional cuts can be made later if necessary Disconnect the temperature pressure relief valve drain line When the water heater is drained disconnect the hose from the drain valve Close the drain valve The water heater is now completely disconnected and ready to be removed FIGURE 6 If you have galvanized pipes to the water heater loosen the two galvanized pipes with a pipe wrench at the union in each line Also disconnect the piping remaining to the water heater see Figure 7 These pieces should be saved since they may be needed when reconnecting the new water heater Disconnect the temperature pressure relief valve drain line When the water heater is drained disconnect the hose from the drain valve Close the drain valve The water heater is now completely disconnected and ready to be removed Mineral buildup or sediment may have accumulated in the old water heater This causes the water heater to be much heavier than normal and this residue if spilled
49. ound per square inch 3 5kPa the damage to the gas control valve could result in a fire or explosion from leaking gas If the main gas line shut off serving all gas appliances is used also turn OFF the gas at each appliance Leave all gas appliances shut OFF until the water heater installation is complete A gas line of sufficient size must be run to the water heater Consult the current edition of National Fuel Gas Code ANSI Z223 1 NFPA 54 and your gas supplier concerning pipe size 18 There must be Areadily accessible manual shut off valve in the gas supply line serving the water heater and Asediment trap ahead of the gas control valve to help prevent dirt and foreign materials from entering gas control valve Aflexible gas connector or a ground joint union between the shut off valve and control valve to permit servicing of the unit Be sure to check all the gas piping for leaks before lighting the water heater Use a soapy water solution not a match or open flame Rinse off soapy solution and wipe dry The minimum inlet gas pressure shown on the rating plate is that which will permit firing at the rated input A WARNING Faa e High altitude orifice must be installed for operations above 7 700 ft 2 347 m e Contact a qualified installer or service agency Breathing carbon monoxide can cause brain damage or death Always read and understand instruction manual Water heaters covered in this ma
50. out could cause staining FIGURE 7 FACTS TO CONSIDER ABOUT THE LOCATION Carefully choose an indoor location for the new water heater because the placement is a very important consideration for the safety of the occupants in the building and for the most economical use of the water heater This water heater is not for use in manufactured mobile homes or outdoor installation Whether replacing an old water heater or putting the water heater in a new location the following critical points must be observed e Select a location indoors as close as practical to the gas vent or chimney to which the water heater vent is going to be connected and as centralized with the water piping system as possible e Selected location must provide adequate clearances for servicing and proper operation of the water heater CAUTION All water heaters eventually leak Donotinstall without adequate drainage Installation of the water heater must be accomplished in such a manner that if the tank or any connections should leak the flow will not cause damage to the structure For this reason it is not advisable to install the water heater in an attic or upper floor When such locations cannot be avoided a suitable metal drain pan should be installed under the water heater Metal drain pans are available at your local Sears or hardware store Such a metal drain pan must have a minimum length and width of at least 2 inches 51 mm greater tha
51. outlet pipe size of the valve or have any reducing couplings or other restrictions e Shall not be plugged or blocked e Shall not be exposed to freezing temperatures e Shall be of material listed for hot water distribution e Shall be installed so as to allow complete drainage of both the relief valve and the discharge pipe e Must terminate a maximum of six inches above a floor drain or external to the building In cold climates it is recommended that the discharge pipe be terminated at an adequate drain inside the building e Shall not have any valve or other obstruction between the relief valve and the drain Once the boiler is installed and filled with water and the system is pressurized manually test the operation of the pressure relief valve See the maintenance section of this manual for instructions A DANGER e Burn hazard Hot water discharge Keep clear of Temperature Pressure Relief Valve discharge outlet The Temperature Pressure Relief Valve must be manually operated at least twice a year Caution should be taken to ensure that 1 no one is in front of or around the outlet of the Temperature Pressure Relief Valve discharge line and 2 the water manually discharged will not cause any bodily injury or property damage because the water may be extremely hot If after manually operating the valve it fails to completely reset and continues to release water immediately close the cold water inlet to the w
52. proper venting or leakage of combustion products e Rusted flakes around top of water heater A WARNING Flue gases may escape if vent pipe Is not connected Be alert for obstructed sooted or deteriorated vent system to avoid serious injury or death e Do not store corrosive chemicals in vicinity of water heater Chemical corrosion of flue and vent system can cause serious injury or death Breathing carbon monoxide can cause brain damage or death Always read and understand instruction manual Be sure the vent piping is properly connected to prevent escape of dangerous flue gasses which could cause deadly asphyxiation Obstructions and deteriorated vent systems may present serious health risk or asphyxiation Chemical vapor corrosion of the flue and vent system may occur if air for combustion contains certain chemical vapors Spray can propellants cleaning solvents refrigerator and air conditioner refrigerants swimming pool chemicals calcium and sodium chloride waxes bleach and process chemicals are typical compounds which are potentially corrosive If when inspecting the vent system you find sooting or deterioration something is wrong Call the local gas supplier to correct the problem and clean or replace the flue and venting before resuming operation of the water heater 22 BURNER INSPECTION Flood damage to a water heater may not be readily visible or immediately detectable However over a period
53. r who sold it For the replacement parts accessories and owner s manuals that you need to do it yourself For Sears professional installation of home appliances and items like garage door openers and water heaters 1 800 4 MY HOME 1 800 469 4663 Call anytime day or night U S A and Canada WWW Sears com WWW Sears ca Our Home For repair of carry in items like vacuums lawn equipment and electronics call anytime for the location of your nearest Sears Parts amp Repair Service Center 1 800 488 1222 USA 1 800 469 4663 Canada WWW Sears com WWW Sears ca To purchase a protection agreement on a product serviced by Sears 1 800 827 6655 U S A 1 800 361 6665 Canada Para pedir servicio de reparacion a domicilio y para ordenar piezas 1 888 SU HOGAR 1 888 784 6427 sears Registered Trademark Trademark of KCD IP LLC in the United States or Sears Brands LLC in other countries Marca Registrada Marca de F brica de KCD IP LLC en Estados Unidos o Sears Brands LLC in otros pa ses MC Marque de commerce V Marque d pos e de Sears Brands LLC Au Canada pour service en francais 1 800 LE FOYER 1 800 533 6937 WWW Sears ca
54. regular price of any non covered repair service and related installed parts Parts and labor needed to help keep products operating properly under normal use not just defects Our coverage goes well beyond the product warranty No deductibles no functional failure excluded from coverage real protection Once you purchase the Agreement a simple phone call is all that it takes for you to schedule service You can call anytime day or night or schedule a service appointment online The Master Protection Agreement is a risk free purchase If you cancel for any reason during the product warranty period we will provide a full refund Or a prorated refund anytime after the product warranty period expires Purchase your Master Protection Unlimited service calls and nationwide service as often as Agreement today you want us whenever you want us e Expert service by a force of more than 10 000 authorized Sears service technicians which means someone you can trust will be working on your product Some limitations and exclusions apply For prices and e No lemon guarantee replacement of your covered product additional information in the U S A call 1 800 827 6655 if four or more product failures occur within twelve months Coverage in Canada varies on some items For full details x J e Product replacement if your covered product can t be fixed call Sears Canada at 1 800 361 6665 e Annual Preventive Maintenance Check a
55. rules the water heater will not operate properly It could cause DEATH SERIOUS BODILY INJURY AND OR PROPERTY DAMAGE This manual contains instructions for the installation operation and maintenance of the gas fired water heater It also contains warnings through out the manual that you must read and be aware of All warnings and all instructions are essential to the proper operation of the water heater and your safety Since we cannot put everything on the first few pages READ THE ENTIRE MANUAL BEFORE ATTEMPTING TO INSTALL OR OPERATE THE WATER HEATER The installation must conform with these instructions and the local code authority having jurisdiction In the absence of local codes installations should comply with the current edition of The National Fuel Gas Code ANSI Z223 1 NFPA 54 This publication is available from the Canadian Standards Association 8501 East Pleasant Valley Rd Cleveland Ohio 44131 or The National Fire Protection Association 1 Batterymarch Park Quincy MA 02269 e f after reading this manual you have any questions or do not understand any portion of the instructions call the Sears Service Center Carefully plan the place where you are going to put the water heater Correct combustion vent action and vent pipe installation are very important in preventing death from possible carbon monoxide poisoning and fires See figures 1 and 8 through 14 Examine the location to ensure the water heater complies w
56. s away from faucets after extended period of non use Read instruction manual before installing using or servicing water heater INSTALLATIONS IN AREAS WHERE FLAMMABLE LIQUIDS VAPORS ARE LIKELY TO BE PRESENT OR STORED GARAGES STORAGE AND UTILITY AREAS ETC Flammable liquids such as gasoline solvents propane LP or butane etc and other substances such as adhesives etc emit flammable vapors which can be ignited by a gas water heater s pilot light or main burner The resulting flashback and fire can cause death or serious burns to anyone in the area as well as property damage If installation in such areas is your only option then the installation must be accomplished in a way that the pilot flame and main burner flame are elevated from the floor at least 18 inches While this may reduce the chances of flammable vapors from a floor spill being ignited gasoline and other flammable substances should never be stored or used in the same room or area containing a gas water heater or other open flame or spark producing appliance NOTE Flammable vapors may be drawn by air currents from other areas of the structure to the appliance A DANGER Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance Also the water heater must be located and or protected so it is not subject to physical damage by a moving vehicle A WARNING For continued protection against ri
57. s designated opening nor plugged The temperature pressure relief valve must be installed directly into the fitting of the water heater designed for the relief valve Position the valve downward and provide tubing so that any discharge will exit only within 6 inches 153 mm above a floor drain or external to the building see Figure 16 Be certain that no contact is made with any live electrical part The discharge opening must not be blocked or reduced in size under any circumstances Excessive length over 30 feet 9 14 m or use of more than four elbows can cause restriction and reduce the discharge capacity of the valve HOT WATER OUTLET COLD WATER a INLET JET np SHUTOFF VALVE TEMPERATURE PRESSURE RELIEF VALVE DISCHARGE PIPE DO NOT CAP OR PLUG rorem ET DRAIN VALVE R ri ze GAP MN FIGURE 17 FLOOR DRAIN No valve or other obstruction is to be placed between the relief valve and the tank Do not connect tubing directly to discharge drain unless a 6 inch air gap is provided To prevent bodily injury hazard to life or property damage the relief valve must be allowed to discharge water in quantities should circumstances demand If the discharge pipe is not connected to a drain or other suitable means the water flow may cause property damage CAUTION Pressure Relief Valve discharge pipe must terminate at adequate drain The Discharge Pipe e Shall not be smaller in size than the
58. sk of fire Do not install water heater on carpeted floor Do not operate water heater if flood damaged This water heater must not be installed directly on carpeting Carpeting must be protected by metal or wood panel beneath the appliance extending beyond the full width and depth of the water heater by at least 3 inches 76 2 mm in any direction or if the appliance is installed in an alcove or closet the entire floor must be covered by the panel Failure to heed this warning may result in a fire hazard A WARNING Read instruction manual before installing using or servicing water heater Improper use may result in fire or explosion Maintain required clearances to combustibles Minimum clearances between the water heater and combustible construction are O inch at the sides and rear 4 inches 102 mm at the front and 6 inches 153 mm from the vent pipe see Figure 8 Clearance from the top of the jacket is 12 inches 305 mm on most models Note that a lesser dimension may be allowed on some models refer to the label attached adjacent to the gas control valve on the water heater TOP VIEW OF CLOSET WITH DOOR REN TOP VIEW OF CLOSET WITHOUT DOOR D e a at EEA ur ra a nt ul at at a uta 104 mm 0 MIN FIGURE 8 A WARNING Install water heater in accordance with the instruction manual and NFPA54 To avoid injury combustion and ventilation air must be taken from outdoors Do
59. t the water heater dimensions and must be piped to an adequate drain The pan must not restrict combustion air flow Water heater life depends upon water quality water pressure and the environment in which the water heater is installed Water heaters are sometimes installed in locations where leakage may result in property damage even with the use of a metal drain pan piped to a drain However unanticipated damage can be reduced or prevented by a leak detector or water shut off device used in conjunction with a piped metal drain pan These devices are available from some plumbing supply wholesalers and retailers and detect and react to leakage in various ways e Sensors mounted in the metal drain pan that trigger an alarm or turn off the incoming water to the water heater when leakage is detected e Sensors mounted in the metal drain pan that turn off the water supply to the entire home when water is detected in the metal drain pan e Water supply shut off devices that activate based on the water pressure differential between the cold water and hot water pipes connected to the water heater Devices that will turn off the gas supply to a gas water heater while at the same time shutting off its water supply A WARNING Avoid all ignition sources if you smell gas Do not expose water heater control to excessive gas pressure Use only gas shown on rating plate Maintain required clearances to combustibles Keep ignition source
60. t your request no extra charge Sears Installation Service e Fast help by phone we call it Rapid Resolution phone For Sears professional installation of home appliances garage door support from a Sears representative on all products Think of openers water heaters and other major home items in the U S A us asa talking owner s manual or Canada call 1 800 4 MY HOME e Power surge protection against electrical damage due to power fluctuations CUSTOMER RESPONSIBILITIES Thank You for purchasing a Kenmore water heater Properly installed and maintained it should give you years of trouble free service If you should decide that you want the new water heater professionally installed by Sears call 1 800 4 MY HOME They will arrange for prompt quality installation by Sears authorized contractors Abbreviations Found In This Instruction Manual e UL Underwriter s Laboratories e CSA Canadian Standards Association e ANSI American National Standards Institute e NFPA National Fire Protection Association e ASME American Society of Mechanical Engineers e EPACT Energy Policy Act This gas fired water heater is design certified by UL Underwriter s Laboratories under American National Standard CSA Standard for Gas Water Heaters ANSI Z21 10 3 CSA 4 3 current edition Read the Safety Precautions section pages 2 3 of this manual first and then the entire manual carefully If you don t follow the safety
61. ter conductivity and should be checked and or replaced more often than an anode rod that appears to be intact Replacement of a depleted anode rod can extend the life of your water heater Inspection should be conducted by calling the Sears Service Center for an authorized contractor The anode rod should be inspected after a maximum of three years and annually thereaf ter until the condition of the anode rod dictates its replacement NOTE artificially softened water requires the anode rod to be inspected annually 23 TEMPERATURE PRESSURE RELIEF VALVE OPERATION The temperature pressure relief valve must be manually operated at least once a year ADANGER Burn hazard Hot water discharge Keep clear of relief valve discharge outlet When checking the temperature pressure relief valve operation make sure that 1 no one is in front of or around the outlet of the temperature pressure relief valve discharge line and 2 that the water discharge will not cause any property damage as the water may be extremely hot see Figure 25 TEMPERATURE PRESSURE RELIEF VALVE DISCHARGE PIPE FIGURE 25A If after manually operating the valve it fails to completely reset and continues to release water immediately close the cold water inlet to the water heater follow the draining instructions and replace the temperature pressure relief valve with a new one If the temperature pressure relief valve on the appliance weeps or
62. tside these areas Propellants of aerosol sprays and volatile compounds cleaners chlorine based chemicals refrigerants etc in addition to being highly flammable in many cases will also change to corrosive hydrochloric acid when exposed to the combustion products of the water heater The results can be hazardous and also cause product failure INSULATION BLANKETS Insulation blankets available to the general public for external use on gas water heaters are not necessary with Kenmore products The purpose of an insulation blanket is to reduce the standby heat loss encountered with storage tank heaters Your Kenmore water heater meets or exceeds the EPACT standards with respect to insulation and standby loss requirements making an insulation blanket unnecessary A WARNING Do not obstruct water heater air intake with insulating blanket Gas and carbon monoxide detectors are available Install water heater in accordance with the instruction manual Breathing carbon monoxide can cause brain damage or death Always read and understand instruction manual A WARNING Should you choose to apply an insulation blanket to this heater you should follow these instructions See Figure 1 for identification of components mentioned below Failure to follow these instructions can restrict the air flow required for proper combustion potentially resulting in fire asphyxiation serious personal injury or death e Do not apply insulati
63. y 4 to 5 times If the pilot will not light repeat step 3 through 9 Continue to hold the gas control knob down for about one 1 minute after the pilot is lit Release the gas control knob and it will pop back up Pilot should remain lit If it goes out repeat step 3 through 9 It may take several minutes for air to clear the lines before the pilot will light If knob does not pop up when released stop and immediately call your service technician or gas supplier If the pilot will not stay lit after several tries turn the gas control knob clockwise to OFF and call your service technician or gas supplier see Figure A 11 Replace the inner and outer burner doors 12 At arm s length away turn gas control knob counterclockwise to ON see Figure C 13 Set thermostat to desired setting DANGER Hot water increases the risk of A scald injury Consult the instruction manual before changing temperature TO TURN OFF GAS TO APPLIANCE 1 Set thermostat to the lowest setting 2 Push gas control knob down slightly and turn clockwise A to OFF Do not force see Figure A 20 TEMPERATURE REGULATION Due to the nature of the typical gas water heater the water temperature in certain situations may vary up to 30 F 16 7 C higher or lower at the point of use such as bathtubs showers sink etc ADANGER Water temperature over 125 F 52 C can cause severe burns instantly resultin
64. y vent damper consult your local Sears Service Center or the local gas supplier for further information To insure proper venting of this gas fired water heater the correct vent pipe diameter must be utilized Any additions or deletions of other gas appliances on a common vent with this water heater may adversely affect the operation of the water heater Consult your gas supplier if any such changes are planned For proper venting in certain installations a larger diameter vent pipe may be necessary Consult your local Sears Service Center or gas supplier to aid you in determining the proper venting for your water heater from the vent tables in the current edition of the National Fuel Gas Code ANSI Z223 1 NFPA 54 Periodically check the venting system for signs of obstruction or deterioration and replace if needed The combustion and ventilation air flow must not be obstructed The water heater with draft hood installed must be connected to a chimney or listed vent pipe system which terminates to the outdoors Never operate the water heater unless it is vented to the outdoors and has adequate air supply to avoid risks of improper operation explosion or asphyxiation For proper draft hood attachment the draft hood legs may be angled slightly inward Place the draft hood legs in the receiving holes on the top of the water heater The legs will snap in the holes to give a tight fit Secure the legs of the draft hood with the suppl