Home

Kenmore 4.2 cu. ft. Freestanding Gas Range w/ Broil & Serve Drawer - Black Installation Guide

image

Contents

1. back of 0 range e 8 Gas I m Regulator M Gas Regulator Service LI Gas Shut Off Valve shown in the ON position Fig 4c 30 GAS RANGE INSTALLATION INSTRUCTIONS For gas venturi models with electric ignition Fig 4f DO NOT allow regulator to turn on pipe when tightening fittings a Install an external manual gas shut off valve to gas supply line in an accessible location outside ofthe range Be sure you know where and how to shut off the gas supply to the range b Install 1 2 flare union adapter to pressure regulator using NO MORE THAN 15ft Ibs of torque NOTE Be sure to stabilize the left side of the pressure regulator with adjustable wrench before tightening ANY fittings to the pressure regulator Refer to Fig 4d c Tighten the gas supply fitting and or appliance conduit to flare union onthe right side of the pressure regulator using NO MORE THAN 15ft Ibs of torque Be sure to stabilize the 1 2 flare union adapter with an adjustable wrench before tightening the gas supply fitting and or appliance conduit Refer to Fig 4e d Install flare union adapter to external manual shut off valve e Attach appliance conduit to flare union on shut off valve f Make sure service shut off valve on pressure regulator is in the ON position See Fig 4f g Check for leak
2. Model and Serial Number Location The serial plate is located under the lift up cooktop When ordering parts for or making inquires aboutyour range always be sure to include the model and serial numbers and a lot number or letter from the serial plate on your range Your serial plate also tells you the rating of the burners the type of fuel and the pressure the range was adjusted for when it left the factory Before You Call for Service Check to make sure the house fuses or circuit breakers for your range are not blown or open Refer to the Avoid Service Checklist and operating instructions in your Owner s Guide It may save you time and expense The list includes common occurrences that are not the result of defective workmanship or materials in this appliance Refer to the warranty in your Owner s Guide for our toll free service number and address Please call or write if you have inquiries about your range product and or need to order parts Care Cleaning and Maintenance Refer to the Owner s Guide for operating and cleaning instructions If removing the range for cleaning or maintenance shutoff gas supply Disconnect the gas and electrical supply Ifthe gas or electrical supply is inaccessible lift the appliance slightly at the front and pull out away from the wall Pull only as far as necessary to disconnect the gas and electrical supply Finish removing the unit for servicing and cleaning Reinstall in reverse order making su
3. EVENT OF A POWER FAILURE The electric ignitor will automatically re ignite the oven burner when power resumes if the oven thermostat control was left in the ON position When an electrical power failure occurs during use the surface burners will continue to operate During a power outage the surface burners can be lit witha match Hold a lighted match to the burner then slowly turn the knob to the LITE position Use extreme caution when lighting burners this way 30 GAS RANGE INSTALLATION INSTRUCTIONS For gas venturi models with electric ignition Before Starting Tools You Will Need For leveling legs and Anti Tip Bracket e Adjustable wrench or channel lock pliers aN e 5 16 Nutdriver or Flat Head Screw Driver ESj Electric Drill amp 1 8 Diameter Drill Bit 5 32 Masonry Drill Bit if installing in concrete For gas supply connection e Pipe wrench For burner flame adjustment e Phillips head and blade type screwdrivers For gas conversion LP Propane or Natural e Open end wrench 1 2 D T Additional Materials You Will Need e Gas line shut off valve adhe e Pipe joint sealant that resists action of LP Propane gas a n e Anew flexible metal appliance conduit 1 2 NPT x 3 4 or 1 2 1 D must be design certified by CSA International Because solid pipe restricts moving the range we recommend using a new flexible conduit 4 to 5 foot length for each new installation and ad
4. Within 60 seconds the broil burner should ignite Check for proper flame Reset controls to off Burner 74 Baffle Oven Burner Tube Air Shutter Lock p Screw Air Shutter mm Orifice Hood 9 AirShutter Oven Burner The approximate flame length of the oven burner is 1 inch distinct inner blue flame To determine if the oven burner flame is proper remove the oven bottom and burner baffle and set the oven to bake at 300 F Toremove the oven bottom remove oven hold down screws at rear of oven bottom Pull up at rear disengage front of oven bottom from oven front frame and pull the oven bottom out of the oven Remove burner baffle so thatthe burner flame can be observe Ifthe flame is yellow incolor increase air shutter opening size If the flame is a distinct blue reduce the air shutter opening size To adjust loosen lock screw reposition air shutter andtighten lock screw Replace oven bottom 10 Make Sure Range is Level Level the range by placing a level horizontally on an oven rack Check diagonally from front to back then level the range by either adjusting the leveling legs or by placing shims under the corners of the range as needed 11 After installation is complete make sure all controls are leftin the OFF position 30 GAS RANGE INSTALLATION INSTRUCTIONS For gas venturi models with electric ignition
5. 30 GAS RANGE INSTALLATION INSTRUCTIONS For gas venturi models with electric ignition INSTALLATION AND SERVICE MUST BE PERFORMED BY A QUALIFIED INSTALLER IMPORTANT SAVE FOR LOCAL ELECTRICAL INSPECTOR S USE READ AND SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE If the information in this manual is not followed exactly a fire or explosion may result causing property damage personal injury or death FOR YOUR SAFETY Refer to your serial plate for Donotstore or use gasoline or other flammable vapors applicable agency certification and liquids in the vicinity of this or any other appliance WHAT TO DO IF YOU SMELL GAS A WARNING e Do not try to light any appliance X e ALL RANGES CANTIP Do not touch any electrical switch do not use any phone Stir a BERBONE in your building COULD RESULT e i i i y e INSTALL ANTI TIP Immediately call your gas supplier from a neighbor s EE AE Ti phone Follow the gas supplier s instructions RANGE If you cannot reach your gas supplier call the fire coN M department Installation and service must be performed byaqualified Note For appliances installed in the installer service agency or the gas supplier Commonwealth of Massachusetts see page 2 OVE
6. If the flame is yellow in color increase air shutter opening size If the flame is a distinct blue but lifting away from the burner reduce the air shutter opening size 8 Oven Burner Adjustments Operation of electric igniters should be checked after range and supply line connectors have been carefully checked for leaks and range has been connected to electric power The oven burner is equipped with an electric control system as well as an electric oven burner igniter These control systems require no adjustment When the oven is set to operate current will flow to the igniter It will glow similar to a light bulb When the igniter has reached a temperature sufficient to ignite gas the electrically controlled oven valve will open and flame will appear at the oven burner There is a time lapse from 30 to 60 seconds after the thermostat is turned ON before the flame appears at the oven burner When the oven reaches the dial setting the glowing igniter will go off The burner flame will go out in 20 to 30 seconds after the igniter goes OFF To maintain any given oven temperature this cycle will continue as long as the dial or display is set to operate After removing all packing materials and literature from the oven a Setovento BAKE at 300 F See Owner s Guide for operating instructions b Within 60 seconds the oven burner should ignite Check for proper flame and allow the burner to cycle once Reset controls to off c
7. Observe all governing codes and ordinances 4 Be sure to leave these instructions with the consumer Important Note to the Consumer 1 Keep these instructions with your Use amp Care Guide for future reference IMPORTANT SAFETY INSTRUCTIONS Installation of this range must conform with local codes or in the absence of local codes with the National Fuel Gas Code ANSI Z223 1 latest edition when installed in the United States When installed ina manufactured mobile home installation must conform with the Manufactured Home Construction and Safety Standard Title24 CFR Part 3280 formerly the Federal Standard for Mobile Home Construction and Safety Title 24 HUD Part280 or when such standard is not applicable the Standard for Manufactured Home Installations ANSI NCSBCS A225 1 or with local codes This range has been design certified by CSA International As with any appliance using gas and generating heat there are certain safety precautions you should follow You will find them in the Use amp Care Guide read it carefully e Besureyourrange isinstalled and grounded properly by a qualified installer or service technician e This range must be electrically grounded in accordance with local codes or in their absence with the National Electrical Code ANSI NFPA No 70 latest edition when installed in the United States See Grounding Instructions on page 5 e Before installing the range in an area covered with linole
8. RALL 2534 FRONT SIDE DIMENSIONS 291 4 incl do 30 we 29 incl door handle VIEW VIEW Minimum to Side Wall Minimum to 13 gt i on Either 18 Cabinets on Maximum Depth 48 Side of 2 gt Either Side for Cabinets Maximum I Range 2 i of Range Above Range Top or 0 0 prar r yo 36 463 8 door open We v ae i 30 gt 0 Clearance Below Cooking Top and at Rear of Range Clearances and Dimensions Provide Proper Fuel Type 1 Location Check location where the range will be Before Proceeding Your range is preset to operate on installed Check for properelectricalandgassupply natural gas and the stability of the floor 2 Dimensions that are shown must be used Given DO NOT attempt to convert this range to LP dimensions provide minimum clearance Contact Propane settings without the proper LP Propane conversion surface must be solid and level kit provided with the range or obtained from your dealer Follow all instructions provided with the LP Conversion Kit p n 316469107 EN SP 0810 Espa ol Paginas 9 16 30 GAS RANGE INSTALLATION INSTRUCTIONS For gas venturi models with electric ignition Important Notes to the Installer 1 Read all instructions contained in these installation instructions before installing range 2 Removeallpacking material from the oven compartments before connecting the gas and electrical supply to the range 3
9. ditional reinstallations a e Always use the 2 new flare union adapters 1 2 NPT x 3 4 or 1 2 D supplied with the new flexible appliance conduit for connection of the range Normal Installation Steps 1 Anti Tip Bracket Installation Instructions Important Safety Warning To reduce the risk of tipping of the range the range must be secured to the floor by properly installed anti tip bracket and screws packed with the range Failure to install the anti tip bracket will allow the range to tip over if excessive weight is placed on an open door or if a child climbs upon it Serious injury might result from spilled hot liquids or from the range itself If range is ever moved to a different location the anti tip brackets must also be moved and installed with the range Instructions are provided for installation in wood or cement fastened to either the floor or wall When installed to the wall make sure that screws completely penetrate dry wall and are secured in wood or metal When fastening to the floor or wall be sure that screws do not penetrate electrical wiring or plumbing A Locate the Bracket Using the Template Bracket may be located on either the left or right side of the range Use the information below to locate the bracket if template is notavailable Markthe floor or wall where left or right side of the range will be located If rear of range is against the wall or no further than 1 1 4 from wall when insta
10. ed climbing on the range to reach items e To eliminate the need to reach over the surface burners cabinet storage space above the burners should be avoided e Adjust surface burner flame size so it does not extend beyond the edge of the cooking utensil Excessive flame is hazardous e Donotuse the oven as a storage space This creates a potentially hazardous situation e Never use your range for warming or heating the room Prolonged use of the range without adequate ventilation can be dangerous e Do not store or use gasoline or other flammable vapors and liquids near this or any other appliance Explosions or fires could result e Reset all controls to the off position after using a programmable timing operation FOR MODELS WITH SELF CLEAN FEATURE Remove broiler pan food and other utensils before self cleaning the oven Wipe up excess spillage Follow the cleaning instructions in the Use amp Care Guide Special instructions for appliances installed in the Commonwealth of Massachusetts This appliance can only be installed in the Commonwealth of Massachusetts by a Massachusetts licensed plumber or gas fitter When using a flexible gas connector it must not exceed 3 feet 36 inches in length A T handle type manual gas valve must be installed in the gas supply line to this appliance DO NOT MAKE ANY ATTEMPT TO OPERATE THE ELECTRIC IGNITION OVEN DURING AN ELECTRICAL POWER FAILURE RESET ALL OVEN CONTROLS TO OFF IN THE
11. equipped with a 3 prong grounding plug which mates with a standard 3 prong grounding wall receptacle to minimize the possibility of electric shock hazard from this appliance The customer should have the wall receptacle and circuit checked by a qualified electrician to make sure the receptacle is properly grounded and polarized 30 GAS RANGE INSTALLATION INSTRUCTIONS For gas venturi models with electric ignition 6 Operation of Surface Burners Operation of electric igniters should be checked after range and supply line connectors have been carefully checked for leaks and range has been connected to electric power Check Surface Burners To check for proper lighting push in and turn a surface burner knob to the LITE position Each burner should light within four 4 seconds in normal operation Once the burner lights the knob should be rotated out of the LITE position Try each knob separately until all burner valves have been checked Air Shutter S adjustment 7 Airadjustment The air shutter adjustment for each of the four top burners is located at the open end of the venturi tube and sets on the hood of the valve Should the air shutter need adjusting rotate the air shutter to allow more or less air into the burner tubes as needed If the air is properly adjusted the flame will be steady relatively quiet and have approximately 1 2 sharp blue cone Usually about the center of air shutter s ajustment
12. lled you may use the wall or floor mount method If molding is installed and does not allow the bracketto fit flush against the wall remove molding or mount bracketto the floor For wall mount locate the bracket by placing the back edge of the template against the rear wall and the side edge of template on the mark made referencing the side of the range Place bracket ontop of template and mark location of the screw holes in wall If rear of range is further than 1 1 4 from the wall when installed attach bracket to the floor For floor mount locate the bracket by placing back edge of the template where the rear of the range will be located Mark the location of the screw holes shown in template B Drill Pilot Holes and Fasten Bracket Drill a 1 8 pilot hole where screws are to be located If bracket is to be mounted to the wall drill pilot hole at an approximate 20 downward angle If bracket is to be mounted to masonry or ceramic floors drilla 3 16 pilot hole 1 3 4 deep The screws provided may be usedin wood or concrete material Use a 5 16 nut driver or flathead screwdriver to secure the bracket in place FASTEN BRACKET wa t or FLOOR MOUNTING gt lt 1 1 4 Max Wall Mount l ETA S Be Wall Plate 7 Bracket FASTEN BRACKET FLOOR MOUNTING ONLY Leveling Leg Rear of Range Floor Mount gt lt More Than Leveling Leg 1 1 4 a S g
13. nection details first then connect electricity to range NANNA Before servicing disconnect electrical supply at circuit breaker fuse or power cord Electric Requirements A dedicated properly grounded and polarized branch circuit protectedby a 15 amp circuit breaker or time delay fuse See serial plate for proper voltage Extension Cord Precautions Because of potential safety hazards under certain conditions we strongly recommend against the use of any extension cord However if you still elect to use an extension cord itis absolutely necessary that it be a UL listed 3 wire grounding type appliance extension cord and that the current carrying rating of the cord in amperes be equivalent to or greater than the branch circuit rating Such extension cords are obtainable through your local service organization PLEASE READ CAREFULLY For personal safety this product must be properly grounded Preferred Method Do Not Under Any Circumstances Cut Remove or Bypass the Grounding Prong Power Supply Grounding Cord with Type 3 Prong Wall Grounding Receptacle Plug Where astandard two prong wall receptacle is encountered itis the personal responsibility and obligation of the customer to have it replaced with a properly grounded three prong wall receptacle DO NOT UNDER ANY CIRCUMSTANCES CUT OR REMOVE THE THIRD GROUND PRONG FROM THE POWER CORD Grounding Instructions The power cord of this appliance is
14. re to level the range and check gas connections for leaks See Anti Tip Instructions for proper anchoring instructions
15. regulator must be at least 1 inch greater than regulator manifold pressure Examples If regulator is set for natural gas 4 inch manifold pressure inlet pressure must be at least 5 inches if regulator has been converted for LP Propane gas 10 inch manifold pressure inlet pressure must be at least 11 inches Leak testing of the appliance shall be conducted according to the instructions in step 4g The gas supply line should be 1 2 or 3 4 I D 3 Seal wall openings Seal any openings in the wall behind the range andin the floor under the range after gas supply line is installed 4 Connect the range to the gas supply NOTE To prevent leaks use pipe joint sealant on all male outside pipe threads Please note Models without self cleaning G feature may Le have an a Centerline additional 4 to of range 7 inches clearance from gt 11 1 2 the floor Recommended area for 120V outlet on rear of wall and area for thru the wall connection of pipe stub and shut off 15 valve is shaded area 5 Wall Recommended area for thru a Edge the floor connection of Fig i 4a pipe stub and shut off valve Manual Flare Flexible Flare Union Pressure Shutoff Union Appliance Adaptor Regulator Valve Conduit 4 mpnoguu rupan On A Off Service Shut Off Valve Electric Ignition models a Shown in ON Position Be sure lever is in the On position when installation is complete Fig 4b
16. s Turn the gas supply on to the range and use a liquid leak detector at all joints and conduits to check for leaks in the system ZG Do not use flame to check for gas leaks Checking Manifold Gas Pressure Disconnect the range andiits individual shut off valve from the gas supply piping system during any pressure testing of that system at test pressures greater than 14 of water column pressure approximately 1 2 psig The appliance must be isolated from the gas supply piping system by closing its individual manual shut off valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 14 of water column pressure approximately 1 2 psig If it should be necessary to check the manifold gas pressure connect manometer water gauge or other pressure device to the top burner right rear orifice Using a rubber hose with inside diameter of approximately 1 4 hold tubing down tight over orifice Turn burner valve on For an accurate pressure check have atleast two 2 other top burners burning Be sure the gas supply inlet pressure is at least one inch above specified range manifold pressure The gas supply pressure should never be over 14 water column When properly adjusted for Natural Gas the manifold pressure is 4 For LP Propane Gas the manifold pressure is 10 30 GAS RANGE INSTALLATION INSTRUCTIONS For gas venturi models with electric ignition 5 Read these electrical con
17. um or any other synthetic floor covering make sure the floor covering can withstand heat at least 90 F above room temperature without shrinking warping or discoloring Do not install the range over carpeting unless you place an insulating pad or sheet of 1 4 inch thick plywood between the range and carpeting Make sure the wall coverings around the range can withstand the heat generated by the range e Donotobstructthe flow of combustion air atthe oven vent nor around the base or beneath the lower front panel of the range Avoid touching the vent openings or nearby surfaces as they may become hot while the oven is in operation This range requires fresh air for proper burner combustion e Air curtain or other overhead range hoods which operate by blowing a downward air flow on to a range shall not be used in conjunction with gas ranges other than when the hood and range have been designed tested and listed by an independenttest laboratory for use in combination with each other Never leave children alone or unattended in the area where an appliance is in use As children grow teach them the proper safe use of all appliances Never leave the oven door open when the range is unattended Stepping leaning or sitting on the doors or drawers of this range can result in serious injuries and can also cause damage to the range e Do not store items of interest to children in the cabinets above the range Children could be seriously burn
18. wall Floor Mount ade am Bracket 30 GAS RANGE INSTALLATION INSTRUCTIONS For gas venturi models with electric ignition C Leveland Position Range Level range by adjusting the 4 leveling legs with awrench Note Aminimum clearance of 1 8 is required between the bottom of the range and the leveling leg to allow room for the bracket Use aspiritlevel to check your adjustments Slide range back into position Visually check that rear leveling leg is inserted into and fully secured by the Anti Tip Bracket by removing lower panelor storage drawer For models with awarmer drawer or broiler compartment grasp the top rear edge of the range and carefully attempt to tilt it forward A 17mm e y os AE er a gt cs o fen N gt Range Side a 2 Provide an adequate gas supply This appliance is pre setto operate on 4 natural gas manifold pressure The pressure regulator MUST be connected in series with the gas supply line If the LP Propane conversion kit has been used follow instructions provided with the kit for converting the pressure regulator to LP Propane use The LP kit can be found on the back side of the range some models Care must be taken during installation of range not to obstruct the flow of combustion and ventilation air For proper operation the maximum inlet pressure to the regulator should be no more than 14 inches of water column pressure The inlet pressure to the

Download Pdf Manuals

image

Related Search

Related Contents

Manuel d`utilisation Analyseur d`humidité sans fil Modèle MO270  取扱説明書 `ネオスリム蛍光灯    Manuale (MY15.0)  Samsung MM-DG35 Εγχειρίδιο χρήσης  Function - Euroburners  

Copyright © All rights reserved.
Failed to retrieve file