Home
Kenmore D42 M32701 User's Manual
Contents
1. 2 Prefilter Nz Negative lons bs and Clean Air 3 lonizing Section 6 lonizing Needle HOW IT WORKS Dirty air is drawn in through the front grill and passes through a 4 stage filtering system The Prefilter consists of aluminum mesh and a close knit polymesh It prevents larger particles lint and hair from entering the collecting cell The next step is a 2 Stage Electrostatic Collecting Cell Dirt particles are charged with a high positive voltage by a series of fine ionizing wires The charged particles are drawn through to the collecting plates where the dirt adheres to the grounded plates and remains until the cell is taken out and washed Removes particles down to 0 01 micron 1 2 540 000 of an inch The air is then drawn through an Activated Carbon Odour amp Gas VOC Volatile Organic Compound Removal Filter to help remove offensive odours and gases Clean air is then discharged out the top of the Air Cleaner Dual Negative lonizer needles are located in the clean air stream Adding healthy negative ions to the air revitalizes the air similar to that near a waterfall spring the ocean or after a rainfall Studies have shown that negative ions have a beneficial effect on human biochemistry both physically and mentally OPERATING INSTRUCTIONS 1 Remove the Air Cleaner from the box and check for apparent damage If your unit has any signs of damage immediately contact the store where the Air Cleaner was purc
2. OWNER S MANUAL MODEL D42 M32701 ELECTRONIC AIR CLEANER IONIZER amp VOC FILTER IMPORTANT PLEASE READ MANUAL BEFORE OPERATING UNIT Features e Lifetime Electronic Filter never needs replacing simply washes clean e Electronically removes dust mites pollen pet dander mold bacteria viruses tobacco smoke cooking smoke and grease and more down to 0 01 micron e Activated Carbon Odour amp Gas VOC Removal Filter removes Volatile Organic Compounds emitted from common sources within the home and office Dual Negative lonizer restores the air s natural ion balance Quiet 3 Speed Fan is comfortable for room occupants Performance Indicator Light shows Air Cleaner is operating properly at a glance Ideal for rooms up to 320 ft 29 5 m for one room air change every 20 minutes SEARS CANADA INC TORONTO ONTARIO M5B 2B8 BENEFITS e Helps provide relief from allergy asthma and respiratory illness e Helps clear a smokey environment quickly so everyone can work and relax together e Helps reduce the time and money spent cleaning and redecorating Prevents damaging black dust from staining walls upholstery and window coverings e Helps reduce tobacco cooking and pet odours e Revitalizes the air with healthy negative ions e Improves indoor air quality for a fresher more comfortable environment year round NB 1 Dirty Air 4 Collecting Cell Plates Praia a 5 Odour amp Gas Removal Filter
3. reinserting back into Air Cleaner The arrow on the cell must point toward the fan blower 5 If arcing or Snapping occurs or the lights do not come on when the cell is placed back in the unit and turned on then remove the cell and allow to dry longer ODOUR amp GAS VOC REMOVAL FILTER Activated Carbon Odour amp Gas VOC Filter Collecting Cell Prefilter 1 The Activated Carbon Odour amp Gas VOC Removal Filter must be replaced at regular intervals if odour removal is desired approximately every 3 6 months ODOUR REMOVAL FILTERS ARE NOT WASHABLE CABINET 1 Turn Air Cleaner OFF 2 A soft damp lint free cloth may be used to remove dirt and fingerprints from painted surfaces grills and end panels NEVER USE AN ABRASIVE CLEANER ON THE CABINET WARNING e DO NOT WASH DISHWASHER e Never use any object to clean between the cell plates as this may cause damage to the plates or ionizing wires e Never place the cell in an oven to dry e The edges of the cell may be sharp handle with care COLLECTING CELL IN DAX Detergent No 32921 and the Activated Carbon Odour amp Gas VOC Removal Filter No 32711 are ae _ available from your Sears i L outlet ih Cell Output Voltage 6500 VDC lt 1 mA Collecting Cell 756 in Surface TROUBLESHOOTING CHART PROBLEM CAUSE Fan does not operate e Unit not plugged in Both Operation Lights off e System switch not ON e Fan s
4. Cleaner near water i e near a bathtub sink laundry tub in a wet basement in the rain or near a swimming pool etc operating instructions unplug the unit from the wall outlet and refer servicing to qualified service personnel LIMITED ONE YEAR WARRANTY Your Electronic Air Cleaner is guaranteed for one 1 full year from the date of original purchase against electrical and mechanical defects in material and workmanship under normal use and maintenance which will be repaired or replaced without charge upon inspection by an authorized service center The warranty does not include the Prefilter or Carbon Filter This guarantee is in lieu of any other warranty either expressed or implied SEARS CANADA INC will not be responsible for Normal maintenance including cleaning or replacement of filters as outlined in the Owner s Manual Damage or repairs needed as a consequence of any misuse negligent handling improper servicing unauthorized alteration improper operations or use on voltage other than that stamped on the Air Cleaner Any personal injury property damage or any incidental or consequential damages of any kind resulting from defects malfunctions misuse or alteration of the product Damage as a result of floods winds fires lightning accidents corrosive atmosphere or other conditions beyond the control of Sears Canada Inc Parts including filters not supplied or designated by Sears Canada Inc If warr
5. Watts maximum 221 m 3 hr 136 m3 hr 102 m3 hr 4877 cm Air Flow Negative lonizer 5000 VDC lt 1 mA Negative lon Output 2 x 327 7 K ins 2 x 20 K cm Ideal for rooms up to 1 room air change 320 ft 29 5 m every 20 minutes for maximum room size IMPORTANT SAFEGUARDS Safety points you should know about your Electronic Air Cleaner and lonizer Caution Read Owner s Manual and safeguards before using Save Owner s Manual for later use Follow all warnings and instructions marked on Air Cleaner FOR YOUR PERSONAL SAFETY The Air Cleaner is equipped with a grounded plug Do not defeat the purpose of this plug by removing the grounding pin as this may result in an electrical shock or create an unsafe condition If liquid has been spilled into the Air Cleaner unplug the unit from the wall outlet and refer servicing to qualified service personnel 10 Do not use the Air Cleaner near open fire or flame or sources When the power cord or plug is damaged or frayed unplug the of heat i e fireplaces wood burning stoves kerosene heaters Air Cleaner from the wall outlet and refer servicing to qualified stove tops ovens etc service personnel 11 Do not use the Air Cleaner on soft surfaces i e beds sofas Do net overload wall outlets and extension cords as this can 12 Do not use the Air Cleaner when oxygen is being used or when result in fire or electric shock combustible gases are present ns
6. anty service is required take the Electronic Air Cleaner into the nearest Sears outlet or Sears Parts amp Service Center with a proof of purchase The original carton and packaging must be used If not and if goods arrive damaged due to improper packaging warranty will be void For more information call Toll Free 1 800 267 8305 32701 pub 05 06
7. e between the holes in the cabinet bottom is 16 3 4 in 42 5 cm 4 After placing the screws in the wall adjust the amount of the screw sticking out to approximately 1 8 in 32 cm Place the Air Cleaner over the screw head and allow the head to slip into the keyhole slot Pull the unit down Slightly to allow the screw head to slide into the smaller portion of the slot CLEANING INSTRUCTIONS The prefilter and collecting cell must be washed on a regular basis for the Air Cleaner to function at its peak efficiency The frequency of cleaning will vary from one environment to another therefore the cell should be checked monthly to determine cleaning schedule On average the cell should be washed every 2 3 months COLLECTING CELL 1 Turn Air Cleaner OFF Remove the cell from the Air Cleaner Slide the prefilter and carbon filter out of the retaining brackets before cleaning 2 Rinse prefilter and cell and spray completely with DAX Detergent or non chlorine non corrosive non abrasive non ammonia liquid household detergent Let stand for 5 minutes Rinse well with hot water 120 F 49 C maximum Repeat process 3 times 3 If dirt remains let cell soak in a solution of DAX Detergent and hot water for 30 minutes 4 For drying place the cell on a 45 angle on one end with the arrow pointing sideways and let stand for 10 24 hours A hair dryer may be used to speed up drying time Make sure the cell is completely dry before
8. hased 2 Keep the shipping carton in case the need arises to store or transport the unit 3 Remove all packaging from the unit Choose a suitable table or stand to allow unobstructed circulation from front and top of unit The unit performs best when the back is against a wall This enhances air circulation To mount unit on wall refer to the Wall Mount Instructions Operate Air Cleaner at voltage shown on back of unit 5 The System Switch controls the power to the Fan Control Switch and the power board When the System Switch is ON the green light behind the front grill will be illuminated ouhah Lid which activates Safety Interlock Negative lon Emitter Negative lon Control Switch 3 Speed Fan Control Switch System Switch Operation Lights onarkwhNh 6 The Fan Control Switch in the front position is low speed the center position is medium and the rear position is high speed Use the low or medium speed for quiet continuous or nighttime use Use the high speed for initial cleaning of heavy concentrations of dirty air i e smoke or after leaving the room 7 The negative ions are controlled by a separate switch located behind the fan control switch When the switch is ON the red light will be illuminated Note The Negative lon Emitter will not work without the System Switch bei
9. ng ON 8 To access the prefilter collecting cell or activated carbon filter press firmly on the right front dimple on the lid and release Lift the lid releasing it from the magnet You may notice arcing or snapping from the cell It is normal to hear some arcing when the unit is new or first turned on Arcing in the cell may also be caused by high humidity over 80 after washing or when a large particle of dirt or hair is caught in the cell If the arcing is continuous and constant then refer to the Troubleshooting Chart WALL MOUNT INSTRUCTIONS 1 To mount Air Cleaner on wall remove the rear feet 2 from the bottom of the Air Cleaner to expose the keyhole slots 2 To remove the feet from the Air Cleaner you will need a small flat screwdriver Pry up the center pin of the rear foot until the head protrudes above the foot Place the flat portion of the screwdriver under the foot and pry up This will release the foot from the cabinet Keep the feet in case you wish to table mount the unit in future 3 Find the location on the wall where you wish to place the Air Cleaner The unit should be placed 3 feet 1 m below the ceiling Use appropriate fasteners for the type of wall the unit will be mounted and insure the head of the screw will fit into the larger opening of the keyhole slot The screw head should be larger than the smaller opening of the keyhole The Air Cleaner weighs approximately 20 lbs 9 kg The distanc
10. rae ieee P on OL rel a a and 13 The Air Cleaner has slots or openings in the cabinet for a O o ee re oad tine ee eel er ventilation purposes to provide reliable operation of the unit ep ere are a aveen netic and to protect it from overheating These openings must not be Do not attempt to service the Air Cleaner yourself as opening or blocked or covered ee a fee sone yon EEI ere a 14 The Air Cleaner should be operated only from the type of power SES MACAO a reer ey ung he Meee Penne source indicated on the rating label If you are not sure of the Never push objects of any kind into the Air Cleaner through type of power supply at your home consult your local power cabinet slots as they may touch dangerous voltage points or company short out parts that could result in a fire or electric shock 15 It is normal for the Air Cleaner to make occasional snapping or If the Air Cleaner has been dropped or the cabinet has been popping sounds particularly when being turned on after damaged unplug the unit from the wall outlet and refer washing If the snapping or popping is continuous or frequent servicing to qualified service personnel unplug the unit and call 1 800 267 8305 Unplug the Air Cleaner from the wall outlet before cleaning Do 16 If the Air Cleaner does not operate normally by following the not use liquid cleaners or aerosol cleaners on cabinet Use a damp lint free cloth for cleaning except when cleaning the cell Do not use the Air
11. witch not in proper position e Lid not securely closed e Negative lon switch not in ON position Green Performance Light on Red lon Light off Fan operating e Cell wet from washing Both Operation Lights off e Short in cell see below Cell arcing excessively Cell wet from washing Cell plate s bent Cell dirty or large lint ball hair caught in cell Broken ionizing wire s Prefilter is in backward black mesh should be visible on outside Air Cleaner vibrating e Unit not sitting on flat surface excessively Both Operation Lights on e Cell is in backward Arrow on cell Cell not collecting dirt should point towards fan blower The two Operation Lights located behind the front grill are also used as the high voltage fault indicator If the fan is operating but the lights do not come on then there is a problem in the high voltage circuit To determine what the problem is turn the Air Cleaner OFF and remove the collecting cell Close the lid and turn the Air Cleaner back ON If the lights come back on the problem lies in the cell Check the cell for wetness from washing or look for a broken ionizing wire s or bent cell plate s If the lights do not come on the problem is with the power board or Operation Light s If you are unable to correct any of the above problems call 1 800 267 8305 TECHNICAL DATA Dimensions Width Depth Height Weight 16 0 lbs 7 3 kg Input Voltage 120 V 60 Hz Power Consumption 85
Download Pdf Manuals
Related Search
Related Contents
TESE para ENVIO - Estudo Geral Instructions/warranty http://www.maiatoys.com Instructions Warning Entretien - Protection Plastiques & Joints Alchimy ようこそ!あさかの生涯学習へ Manual de Instruções GH-PM 40 P - Megekko.nl LMF-400 Owners Manual Savi® W440 - Plantronics GM3600 - Titan Tool USA Copyright © All rights reserved.