Home

Kenmore 580. 75063 User's Manual

image

Contents

1. Use this button to automatically control the temperature of the room The temperature can be set within a range of 60 F to 86 F by increments of 41 F AUTO RESTART When power is restored after an electrical power failure the unit will begin to run at its last setting AIR DIRECTION ADJUSTMENT HORIZONTAL AIR DIRECTION CONTROL The horizontal air direction is adjusted by moving the vertical louvers right and left with your fingertips FIG 13 FIG 13 MODE Every time you push this button it will shift among COOL ENERGY SAVER and FAN ENERGY SAVER The fan stops when the compressor stops cooling Approximately every 3 minutes the fan will turn on and the unit will check the room air to determine if cooling is needed gt SHUT OFF TIME You will usually use shut off time while you sleep With unit running use Timer to set number of hours until shut off For your sleeping comfort once Time is set the Temperature setting will raise 2 F after 30 min and 2 F after another 30 min Every time you push Timer button it advances the Timer setting as follows 1 Hour 2 Hours ete 12 Hours maximum START TIME With unit not running use Timer to set number of hours before unit starts Every time you push Timer button it advances the Timer setting as follows 1 Hour 2 Hours etc 12 Hours
2. oooooiooconccn ccononcccnani nnan 23 C mo y por qu A ia 23 Sonidos Normales ceitrrcccntcrrecenrtnrenanos 23 Capacidad y tiempo de funcionamiento 23 Caracter sticas meerrrrerererrrrenononmenanono 24 Uso del equipo de aire acondicionado 24 Caracter sticas del equipo de aire acondicionado A A ra ee O 25 MANTENIMIENTO A E AA TTET 26 Limpieza del filtro del aire ee tcceecooos 26 Limpieza del equipo de aire acondicionado 26 C mo sacar la rejilla frontale eee 26 C mo a reemplaza el grille anterior 26 CORRECCI N DE FALLAS eee 27 Antes de Llamar para Servicio vss 27 PARA PEDIR SERVICIO Cubierta Trasera GARANT A GARANT A DE UN ANO POR EL EQUIPO DE AIRE ACONDICIONADO DE HABITACION Durante un a o completo a partir de la fecha de compra si este equipo de aire acondicionado recibe mantenimiento y se utiliza para el enfriamiento normal de habitaci n seg n las instrucciones indicadas en este manual del propietario Sears reparar gratuitamente este equipo de aire acondicionado si tiene alg n defecto en materiales o fabricaci n GARANT A TOTAL DE CINCO A OS POR EL SISTEMA DE REFRIGERACI N HERMETICAMENTE SELLADO Durante cinco a os a partir de la fecha de compra si este equipo de aire acondicionado recibe mantenimiento y se utiliza para el enfriamiento normal de habitaci n seg n las instrucciones indicadas en este manual del propietario Sears reparar gratuitamente el sis
3. VENT CONTROL The Vent Control allows the air conditioner to ood D On On Cabinet Air Discharge Vertical Air Deflector Horizontal Louver Air Intake Inlet Grille Air Filter Front Grille Control Panel Power Cord 9 Evaporator Coil 10 Condenser 11 Compressor 12 Base pan 13 Brace 14 Side Louver either recirculate inside air CLOSE or exhaust air to the outside OPEN FIG 12 The CLOSE position is used when maximum cooling is desired lt may also be used for air recirculation without cooling when the air conditioner is set in the FAN position The OPEN position removes stale air from the room and exhausts it to the outside Fresh air is drawn into the room through your home s normal air passages The OPEN or CLOSE position can be used with any fan selection SSN al CLOSE siiis VENT alla OPEN FIG 12 10 OPERATION DISPLAY POWER To turn the air conditioner ON push this button To tum the air conditioner OFF push the button again This button takes priority over any other buttons When you first turn it on the unit is in cool mode High fan speed Temperature setting at 72 F _ REMOTE CONTROL SIGNAL RECEIVER AAA A FAN SPEED gt a Every time you push this button it advances the setting as follows HIGH F3 gt LOW F1 gt MED F2 gt HIGH F3 TIMER TEMPERATURE SETTING
4. no extra charge Fast help by phone phone support from a Sears technician on products requiring in home repair plus convenient repair scheduling Power surge protection against electrical damage due to power fluctuations Rental reimbursement if repair of your covered product takes longer than promised Once you purchase the Agreement a simple phone call is all that it takes for you to schedule service You can call anytime day or night or schedule a service appointment online Sears has over 12 000 professional repair specialists who have access to over 4 5 million quality parts and accessories That s the kind of professionalism you can count on to help prolong the life of your new purchase for years to come Purchase your Master Protection Agreement today Some limitations and exclusions apply For prices and additional information call 4 800 827 6655 Sears Installation Service For Sears professional installation of home appliances garage door openers water heaters and other major home items in the U S A call 1 800 4 MY HOME Acuerdos de Protecci n Especializada Enhorabuena Ha realizado una compra inteligente Su nuevo aparato Kenmore est dise ado y fabricado para ofrecerle a os de buen funcionamiento Sin embargo al igual que todos los productos puede precisar un mantenimiento preventivo o incluso alguna reparaci n de vez en cuando En esas ocasiones un Master Prot
5. 24 min E 40 4 2 max 145 min Ventana de corredera horizontal 45 44 m n Ventana con marco SERVICIO ELECTRICO Compruebe cual es ta alimentaci n el ctrica que lega a su domicilio La alimentaci n el ctrica disponible debe ser la misma que se muestra en la placa del fabricante de la unidad que se halla en el lado derecho del gabinete de corriente alterna Todos los modelos est n equipados con un enchufe de tres espigas para suministrar un servicio correcto y una conexi n a tierra segura y positiva No cambie el enchufe de ninguna forma No use un enchufe adaptador Si su toma de corriente de pared actual no puede usarse con el enchufe del equipo llame a un electricista calificado para que efect e las correcciones necesarias CONSERVE LA CAJA y este MANUAL DEL PROPIETARIO para que le sirva como referencia en el futuro La caja es la mejor manera de conservar la unidad durante el invierno o cuando no est en uso A CUIDADO Para evitar el riesgo de lesiones personales danos a su propiedad o danos al producto debido al peso de este equipo y los filos a que seran expuestos El aire acondicionado del que se habla en este manual afirma peligro de peso excesivo Dos o mas personas se requiere para mover e instalar la unidad Para evitar heridas o agotamiento use tecnicas apropiadas para levntar y mover la unidad Cuidadosament
6. Washer 2 11 Side Guide seal 1 2 Remove protective backing from Window Track 12 Foam Seal Strip 4 Seal and apply seal to window track Fig 2 13 Window Track Seal 1 14 L Bracket 1 Measure and lightiy mark a line 8 1 4 inches 15 Screw Type A 9 from window jamb Center the Support Bracket 16 Screw Type B 3 assembly on the window track and fasten with 17 Screw Type C 8 4 Type C screws Fig 2 REQUIRED TOOLS Window Jamb Tight Fitting gloves Standard screwdriver Phillips screwdriver Pliers Sharp knife 3 8 inch open end wrench or adjustable wrench 1 4 inch hex socket and ratcher Tape measure Electric drill 1 4 inch drill bit o s Window Track Sea TI INSTALLATION 14 Put the Support Bracket against the outside wall and tighten the Bolts on top of the Bracket Adjust the Leveling Bolt so that the air conditioner will be installed with a very slight tilt about 1 4 downward toward the outside for proper drainage Tighten the nut Fig 3 NOTE DO NOT drill a hole in the bottom of the base pan The air conditioner is designed to operate with the bottom of the base pan approximately half full of water About nep ay FIG 3 g Fasten Side Guides to the sides of the Air Conditioner using 3 Type A screws per Guide Start with first screw at middle of Guide Fig 4 6 Fasten Upper Guid
7. maximum VERTICAL AIR DIRECTION CONTROL The vertical air direction is adjusted by moving the horizontal louvers up and down with your fingertips FIG 14 FIG 14 11 ARRIE OPERATION REMOTE CONTROL Note The Remote Control will not operate properly if strong light shines on the sensor window of the Air Conditioner or if there are obstacles between the Remote Control and the Air Conditioner Every time you push button you will hear beep sound from the Air Conditioner Y Temp A gt 4 9 Lm Fan Speed Eo Timer e Modi FIG 15 is 5 TIMER SHUT OFF TIME You will usually use shut off time while you sleep With unit running use Timer to set number of hours until shut off For your sleeping comfort once Time is set the Temperature setting will raise 2 F after 30 min and 2 F after another 30 min Every time you push Timer button it advances the Timer setting as follows 1 Hour gt 2 Hours gt etc gt 12 Hours maximum START TIME With unit not running use timer to set number of hours before unit starts Every time you push Timer button it advances the Timer setting as follows 4 Hour gt 2 Hours etc 12 Hours maximum HOW TO INSERT BATTERIES INTO REMOTE CONTROL Remove the cover from the back of the remote controller 2 Insert two batteries Be sure that the and direc
8. Horas etc 12 Horas maximo AUTO ARRANQUE TIEMPO DE INICIO DE FUNCIONAMIENTO m Si su unidad est apagada el temporizador fija el n mero de 4 En caso de fallo de la corriente el ctrica la horas antes de encenderse gt unidad funcionar como antes cuando Cada vez que oprima el bot n del temporizador har que 2 vuelve la corriente avance el ajuste del temporizador como sigue O 1 Hora gt 2 Horas gt etc gt 12 Horas maximo AJUSTE DE LA DIRECCION DEL AIRE CONTROL HORIZONTAL DEL FLUJO DE AIRE CONTROL VERTICAL DEL FLUJO DE AIRE p A a E La direcci n del flujo de aire vertical se ajusta La direcci n del flujo de aire horizontal se ajusta A z i a 3 girando las rejillas horizonatales hacia arriba o moviendo las rejillas verticales a la derecha o hacia abajo FIG 14 izquierda con la punta de sus dedos FIG 13 3o FIG 14 TABLE OF CONTENTS CONTROL REMOTO 4 VELOCIDAD DEL VENTILADOR Cada vez que oprima este bot n se avanza en el ajuste Nota El Control remoto podr a no funcionar como sigue High F3 Low F1 gt Med F2 gt apropiadamente si hay un reflejo de luz sobre el sensor High F3 del aire acondicionado o si hay obst culos entre el control 5 TEMPORIZADOR remoto y la unidad de aire acondicionado Cada vez que oprime un bot n escuchar una se al ac stica desde el aire acondicionado TIEMPO DE APAGADO Normalmente utilizar el temporiz
9. a oprimir el bot n i COOL ENERGY SAVER y FAN ENFRIAMIENTO Este bot n tiene la prioridad sobre cualesquiera otros AHORRO DE ENERG A y VENTILADOR botones e _ AHORRO DE ENERG A Cuando lo enciende por primera vez el aire acondicionado est en el modo de enfriamiento m s alto y la temperatura en 72 F El ventilador se detiene cuando el compresor deja de enfriar 3 Aproximadamente cada 3 minutos el ventilador se encender CONTROL REMOTO RECEPTOR DE SE AL gt y y se verificar la temperatura de la habitaci n para ver si es necesario enfriar N VELOCIDAD j TEMPORIZADOR DEL VENTILADOR e TIEMPO DE APAGADO Cada vez que oprima este bot n se avanza en el l Normalmente utilizar el temporizador de apagado mientras ajuste de un rango como sigue HIGH F3 duerme i 7 LOW F1 gt MED F2 gt HIGH F3 j Si su unidad est funcionando el temporizador fija el n mero de horas antes de apagarse co Para su comodidad mientras duerme una vez que se fija el ari A cane sok ticamente ia temporizador el ajuste de temperatura se elevar 2 F despu s temperatura de la habitaci n de 30 minutos y una vez m s despu s de otros 30 minutos La temperatura puede ajustarse dentro de un rango Cada vez que oprima el bot n del temporizador har que de 60 F a 86 F de 1 F avance el ajuste del temporizador como sigue 1 Hora gt 2
10. adentro los del panel de la caja s2 TONVdS4 CORRECCI N DE FALLAS ANTES DE LLAMAR PARA SERVICIO Cheque la siguiente lista para asegurarse s en realidad es necesario llamar para servicio Una referencia rapida a este manual puede evitar una llamada para servicio innecesaria EL AIRE ACONDICIONADO NO FUNCIONA Compruebe si Despu s El dispositivo interruptor de corriente est activado Presione el bot n RESET situado en la carcasa del enchufe del cable de alimentaci n Si el bot n RESET no permanece presionado deje de utilizar el equipo y p ngase en contacto con un t cnico de servicio cualificado El enchufe de pared est desconectado Empuje el enchufe firmemente contra la toma de pared Fusible fundido o interruptor de circuito activado Sustituya el fusible por uno de tipo de retardo o reinicie el interruptor de circuito Equipo APAGADO Presione el bot n Power La unidad se apag y despu s se encendi demasiado r pidamente Apague la unidad y espere 3 minutos antes de volver a encenderta El control de TEMP est m s c lido que la temperatura ambiente Establezca el control TEMP a un n mero m s inferior EL AIRE DE LA UNIDAD NO SALE LO SUFICIENTEMENTE FR O Compruebe si Despu s VELOCIDAD DEL VENTILADOR establecida en BAJA Presione el bot n FAN SPEED para fijarlo en Hi Control de TEMP establecido en
11. o de la noche o solicitar una cita para prestaci n de servicios online Sears cuenta con m s de 12 000 t cnicos profesionales especialistas en reparaciones con acceso a m s de 4 5 millones de piezas de sustituci n y accesorios de calidad ste ser el tipo de profesionalidad y servicio con el que podr contar para prolongar la vida de su nuevo producto por muchos a os Adquiera hoy mismo su Master Protection Agreement Se aplicar n algunas limitaciones y restricciones Si desea hacer alguna consulta sobre los precios u otra informaci n adicional le rogamos llame al tel fono 1 800 827 6655 Servicios de Instalaci n Sears Para solicitar servicios de instalaci n profesionales de Sears de electrodom sticos mandos de apertura de puertas de garajes calentadores de agua y otros aparatos en los Estados Unidos puede llamar a 1 800 4 MY HOME Your Home For repair in your home of all major brand appliances lawn and garden equipment or heating and cooling systems no matter who made it no matter who sold it For the replacement parts accessories and owner s manuals that you need to do it yourself For Sears professional installation of home appliances and items like garage door openers and water heaters 1 800 4 MY HOME 1 800 469 4663 Call anytime day or night U S A and Canada www sears com WWw sears ca Our Home For repair of ca
12. periodically and cleaned if they becorne clogged with soot or dirt from the atmosphere Brush or vacuum exterior coils to remove debris from fins HOW TO REPLACE THE FRONT GRILLE Attach the front grille to the cabinet by inserting the tabs on the grille into the slots on the front of the cabinet Push the grille in until it snaps into place 13 HSITONA TROUBLESHOOTING BEFORE CALLING FOR SERVICE Check the following list to be sure a service call is really necessary A quick reference to this manual may help you avoid an unneeded service call THE AIR CONDITIONER WILL NOT OPERATE Check if Then The Current interrupter device is triped Press the RESET button located on the power cord plug If the RESET button will not stay engaged discontinue use of the air conditioner and contact a qualified service technician Wall plug disconnected Push plug firmly into wall outlet House fuse blown or circuit breaker tripped Replace fuse with time delay type or reset circuit breaker Power is OFF Push the power button Unit was turned off and then on too quickly Set unit off and wait 3 minutes before restarting TEMP Control set warmer than room temperature Set TEMP Control to a lower number AIR FROM UNIT DOES NOT FEEL COLD ENOUGH Check if Then FAN SPEED set at LOW Push FAN SPEED button to set at Hi TEMP Control set too warm Set TEMP Control to a lower temperature R
13. sure air conditioner does not fall during installation NOTE Before using the air conditioner secure the front grille with two screws enclosed with the owner s manual 1 Open the inlet grille downward and remove the air filter 2 Fasten the front grille with screws 3 Reinstall the air filter 4 Close the inlet grille Inlet Grille HSITDNaA INSTALLATION INSTALLATION HARDWARE INSTALLATION Pick a location that will allow the air conditioner to blow the cold air into the area you want Windows used for installation must be strong enough to support the weight of the air conditioner Good installation with special attention to the proper position of the unit will lessen the chance that service will be needed When cooling more than one room installation location is very important To coo your rooms cold air must be blown from the air conditioner in a straight path HORIZONTAL SLIDING WINDOW INSTALLATION 1 Loosely attach the Support Bracket to the bottom of Bracket using Bolts Washer and Nuts Attach the Leveling bolt and nut Fig 1 NO NAME OF PARTS QTY 1 Curtain 1 Bolt 2 Curtain Frame 1 Bracket 3 Upper Guide 1 4 Side Guide 2 Washer 5 Support Bracket 4 Nut 6 Bracket 4 6 aa bolt amp nut Support Bracket Leveling Bolt amp Nut o 9 Nut 2 FIG 1 10
14. this air conditioner is operated and maintained for normal room cooling according to instructions in this owner s manual Sears will repair this air conditioner free of charge if defective in material or workmanship FULL FIVE YEAR WARRANTY ON SEALED REFRIGERATION SYSTEM For five years from the date of purchase when this air conditioner is operated and maintained for normal room cooling according to instructions in this owner s manual Sears will repair the sealed refrigeration system consisting of refrigerant connecting tubing and compressor free of charge if defective in material or workmanship WARRANTY SERVICE IS AVAILABLE BY CONTACTING SEARS SERVICE AT 1 800 4 MY HOME Warranty coverage applies only to air conditioners used for non commercial private household purposes This warranty applies only while this product is in use in the United States This warranty gives you specific legal rights and you may also have other right which vary from state to state Distributed by Sears Roebuck and Co Hoffman Estates IL 60179 SAFETY IMPORTANT SAFETY INSTRUCTIONS The safety instructions below will tell you how to use your room air conditioner to avoid harm to yourself or damage to your ROOM AIR CONDITIONER UT FOR your SAFETY Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance Read product labels for flammability and other warnings TEO PREV
15. una trayectoria recta MONTAJE EN UNA VENTANA DE CORREDERA HORIZONTAL 1 Colocar sin apretar el soporte a la parte inferior de la fijaci n usando los tornillos y arandela y tuercas Colocar el tornillo y la tuerca de nivelaci n Fig 1 NO NOMBRE LA PARTE CANTIDAD Tornillo 4 Cortina 4 Soporte 2 Gu s superior 1 3 Gu s lateral 1 Arandela 4 Guide lat ral 2 Tuerca 5 Soporte de fijaci n 1 Z millo de 6 Soporte Soporte de fem nivelaci n y tuerca 7 Tornillo de nivelaci n y tuerca 1 fijaci n Y 8 Tornillo 2 s FIG 1 9 Tuerca 2 10 Arandela 2 2 Quitan la protecci n del sello de la banda del 11 Junta de guis lateral 4 ventana y aplique el sello a la banda del ventana 12 Burlete de espuma 1 Mida y marca suavemente una l nea de 8 1 4 13 Sello del Banda de la ventana 1 pulgadas desde la jamba de la ventana Centre el 14 Soporte de fijaci n de ventana 4 conjunto del soporte en la banda de la ventana y 15 Tomillo tipo A 9 aj stelo 4 tornillos del tipo C Fig 2 16 Tornillo tipo B 3 17 Tornillo tipo C 8 Jamba de 4 A HERRAMIENTAS REQUERIDAS AN Guantes apretados es Destornillador normal Destornillador Phillips Pinsas a Cuchillo filoso 8 L las pulgadas Llave inglesa o llave abierta de 3 8 Llave hexagonal de cubo y trinquete de 1 4 de pulgada Cinta para medir Taladro electric
16. ENT ACCIDENTS To reduce the risk of fire electrical shock or injury to persons when using your air conditioner follow basic precautions including the following Be sure the electrical service is adequate for the model you have chosen if the air conditioner is to be installed in a window you will probably want to clean both sides of the glass first If the window is a triple track type with a screen panel included you may want to remove the screen completely before installation e Be sure the air conditioner has been securely and correctly installed according to the separate installation instructions provided with this manual Save this manual and installation instructions for possible future use in removing or reinstalling this unit Use gloves when handling the air conditioner Be careful to avoid cuts from sharp metal fins on front and rear coils WNT ELECTRICAL INFORMATION The complete electrical rating of your new room air conditioner is stated on the serial plate Refer to the rating when checking the electrical requirements e Be sure the air conditioner is properly grounded To minimize shock and fire hazards proper grounding is important The power cord is equipped with a three prong grounding plug for protection against shock hazards e Your air conditioner must be plugged into in a properly grounded wall receptacle if the wall receptacle you intend to use is not adequately grounded or protected by a
17. Owner s Manual Manual del Propietario Kenmores SLIDER CASEMENT AIR CONDITIONER HORIZONTAL MARCO ACONDICIONADOR DE AIRE Model Modelo 580 75063 580 75123 ZARIE TONVWdS4 Distributed by Sears Roebuck and Co Hoffman Estates IL 60179 www sears com TABLE OF CONTENTS TABLE OF CONTENTS oee 2 WARRANT Y cccececceececccresececenseseeenens 2 SAFE TV ecos 3 Important Safety Instructions eee neess 3 ELECTRICAL REQUIREMENTS 4 INSTALLING THE POWER CORD 4 INSTALLATION cassizain mada 5 installation Requirements eerten 5 installation a a aa 6 Horizontal Sliding Window installation 6 Casement Window Installation es 8 Removal From Window so rs rrr 8 OPERATION egoista 9 How and Why ls nt aaa ble 9 Normal Sounds a 9 Capacity and Running Time esee 9 Features c0errerrerrerrorennmcnonnanonnmnnmnannnrnnnnnnano 10 Using the Air Conditioner s 10 ES 41 Air Direction AdjusStMent oooooooccooo 11 Remote Control ee 12 How To Insert Batteries into Remote Control 42 MAINTENANCE iii 13 Air Filter Cleaning scr 13 Air Conditioner Cleaning oveceesesess 13 How to Remove the Front Grille ecese 13 How to Replace the Front Grille oee e 13 TROUBLESHOOTING eee 14 Before Calling for Service tes 14 ESPA OL cuan icon ibl 16 SERVICE NUMBERS Back Cover WARRANTY FULL ONE YEAR WARRANTY ON ROOM AIR CONDITIONER For one year from the date of purchase when
18. PO DE FUNCIONAMIENTO Al decidir cu l debe ser la comodidad deseada para el rea que usted quiere enfriar es importante determinar el tama o correcto de la unidad Una unidad pequena no tendra la capacidad para enfriar dejando la area calurosa El tama o adecuado es determinado por el n mero de metros cuadrados que tiene el rea que se desea enfriar as como por la temperatura interior y exterior y por la humedad Una unidad demasiado grande si enfria pero no deshumedece dejando la area fria y humeda Siempre que la carga t rmica del ventilador est por encima de fo normal el equipo de aire acondicionado debe funcionar mas tiempo para mantener la temperatura deseada que usted ha seleccionado Bajo condiciones de una carga t rmica muy pesada puede ser necesario que el equipo de aire acondicionado funcione constantemente para mantener la temperatura deseada En ocasiones el uso de MED FAN para hacer circular el aire por la habitaci n hace que el ambiente sea m s confortable aun cuando el equipo no est enfriando el aire Mientras m s tiempo y con mayor frecuencia funcione el equipo de aire acondicionada m s electricidad consumir y mayores ser n los costos de su uso Compresor El moderno compresor de gran eficiencia puede producir un ruido agudo de murmullo o un ruido de pulsaci n que viene y se va Vibraciones de la Ventilador unidad Usted puede La unidad puede vibrar y escuchar el hacer ruid
19. a por persianas cortinas muebles etc La distribuci n del aire est restricta Elimine la obstrucci n de delante de la unidad Las puertas ventanas registros etc Est n abiertos El aire frio se escapa Cierre las puertas ventanas registros etc Unidad recientemente encendida en un cuarto caliente Concede un tiempo adicional para a eliminaci n del calor almacenado en paredes techo suelo y muebles EL AIRE ACONDICIONADO SE ENCIENDE Y APAGA R PIDAMENTE Compruebe si Despu s La temperatura exterior es extremadamente caliente Fije la VELOCIDAD del VENTILADOR en Hi para reducir al m nimo ja carga de enfriamiento La unidad est fijada en modo de ahorro de energ a Aproximadamente cada 3 minutos el ventilador se encender y la unidad comprobar la temperatura del aire del cuarto para determinar si es necesario enfriarlo Este es el funcionamiento normal del modo ahorro de energ a RUIDOS CUANDO LA UNIDAD EST ENFRIANDO Compruebe si Despu s Ruido del ventilador golpeando agua del sistema de Esto es normal cuando la humedad es alta Cierre puertas ventanas y eliminaci n de humedad registros Vibraci n de la ventana instalaci n defectuosa Consulte las instrucciones de instalaci n o consulte con el instalador GOTEO DE AGUA DENTRO DEL CUARTO CUANDO LA UNIDAD EST ENFRIANDO Compruebe si Despu s El aire acondicionado est i
20. ador de apagado mientras duerme 4 6 3 Si su unidad est funcionando el temporizador fija el n mero de horas antes de apagarse Para su comodidad mientras duerme una vez que se fija el temporizador el ajuste de temperatura se elevar 2 F despu s de 30 minutos y una vez m s despu s de otros 30 minutos Cada vez que oprima el bot n del temporizador har que avance el ajuste del temporizador como sigue 1 Hora gt 2 Horas etc gt 12 Horas m ximo TIEMPO DE INICIO DE FUNCIONAMIENTO Si su unidad est apagada el temporizador fija el n mero de horas antes de encenderse 1 Cada vez que oprima el bot n del temporizador har que avance el ajuste del temporizador como sigue 2 1 Hora gt 2 Horas gt etc gt 12 Horas maximo 4 COMO COLOCAR LAS BATERIAS 3 AL CONTROL REMOTO 1 Retire la cubierta de la parte posterior del contro remoto 2 Inserte dos bater as Asegurese de orientar correctamente los polos y FIG 15 Aseg rese que ambas bater as son nuevas 3 Vuelva a colocar la cubierta LAS OPERACIONES DEL CONTROL A REMOTO 1 ENERG A t Para encender el aire acondicionado oprima el bot n FIG 16 Para apagar el aire acondicionado vuelva a oprimir el bot n No utilice bater as recargables Dichas bater as son Este bot n tiene la prioridad sobre cualesquiera otros diferentes de las bater as secas en la forma dimensiones y b
21. arato viene equipado con un cable de alimentaci n y una clavija de tres terminales Para reducir al m ximo el peligro de choque el ctrico CLAVIJA ESTE APARATO NECESITA SER CONECTADO A TIERRA ei cable debe estar conectado a una conexi n de pared con conexi n Se requiere una alimentaci n el ctrica CA adecuadamente A e BON a Ulia l edici n del C digo El ctrico Nacional ANSINFPA 70 asi como con conectada a tierra con un fusible de 15 A de 60 Hz y de ie SAT 2 los c digos y reglamentos locales Si no existe una conexi n de 230 208 V Se recomienda un fusible de retardo o un q Al hae disyuntor de circuito que alimente solamente a este aparato pared adecuada el cliente tiene la responsabilidad y la obligaci n de mandar instalar con un electricista calificado una conexi n de pared NO USE CABLE ELECTRICO DE EXTENSION adecuada de tres terminales con conexi n a tierra El cable de alimentaci n puede incluir un dispositivo interruptor de corriente La carcasa del enchufe cuenta con un bot n de prueba y otro de reinicio El dispositivo debe comprobarse peri dicamente presionando primero el bot n TEST y despu s RESET Si el bot n TEST no se desconecta o si el bot n RESET no permanece activo suspenda el uso del aire acondicionado y p ngase en contacto con un t cnico de servicio cualificado Standard 125V enchufe de 3 L neas de 15A 125V AC Utilice un fusible de 15AMP o
22. ci n Deslizar la cortina del marco en las gufas laterales del armario del aire acondicionado Asegurarse de que la cortina queda firmemente sujeta en todos los lados por el marco Fig 6 Gu s superior Cortina FIG 6 g Corte dos sellos de gu a laterales con la misma longitud Retire la protecci n y apliquelo en el lateral trasero de las gu as laterales del compartimento comenzando por debajo del conjunto del marco de la cortina Corte lo que sobre de forma que el sello quede ajustado al final de la gu a lateral Fig 7 Aplique sellante de clima a las guias laterales justo en el borde inferior de la cortina del molde FIG 7 DFT TONVdS4 INSTALACI N 10 Colocar el aparato de aire acondicionado en la abertura de la ventana Deberia queda asentado sobre el soporte de modo que la cortina del marco y las gu as laterales del armario queden asentadas contra las jambas de la parte superior y laterales de la ventana Compa ero frente del Soporte del corchete con la Gu a baja que asoci el fondo baja de la bandeja 11 Taladre huecos de 1 8 pulgadas en la pista de la banda de ventana de los huecos existents en la Gu a de la Base Atornille 4 tornillos de tipo C a trav s de los huecos Si se trata de la instalaci n de una ventana de bisagras proceda seg n la Instalaci n de ventana de bisagras Deslice el marco corredizo de ventana interior contra el lateral de
23. colocaci n m s fresca la unidad apagar Espere 3 minutos CONTROL DE VENTILACI N FIG 11 El control de ventilaci n permite que el equipo de aire acondicionado haga recircular el aire en el 1 Cabinete 9 Evaporador interior de la habitaci n CLOSE o saque el aire 2 Salida Deaire 10 Condensador hacia el exterior OPEN Figura 12 3 Defleotor De Aire 11 Compresor La posici n CLOSE sirve cuando se desea un Horizontal 12 Bandeja enfriamiento m ximo Tambi n puede usarse para Vent Anillas 43 Suspensores hacer recircular el aire sin enfriar la habitaci n Horizontales 4 4 Persiana aleral cuando el equipo de aire acondicionado se ajusta 4 Recoleotoor i en la posici n FAN De Aire La posici n OPEN extrae el aire estancado de la Bandejade Entrada habitaci n y lo expulsa hacia fuera El aire fresco 5 Eitro Die Aire es llevado hacia el interior de la habitaci n a trav s A de los pasajes normales de aire que se hallan en 6 Grillage Frontal los hogares 7 Panel De Control La posici n OPEN o CLOSE puede usarse con 8 Cable De Conexi n cualquier selecci n de ventilador El ctrica WSS ra CLOSE aiia VENT alla OPEN TIRAR PARA ABRIR EMPUJAR PARA CERRAR FIG 12 24 OPERACI N PANTALLA ENERG A MODO Para encender el aire acondicionado oprima el bot n Para Cada vez que oprime este bot n cambiar entre apagar el aire acondicionado vuelva
24. con un enchufe de tres espigas con conexi n a tierra para protegerie contra riesgos de descargas el ctricas Su equipo de aire acondicionado debe enchufarse en una toma de corriente de pared que tenga una conexi n correcta a tierra Si la toma de corriente de pared que usted piensa usar no est conectada correctamente a tierra o no est protegida con un fusible de acci n retardada o con un interruptor de circuito haga que un electricista calificado le instale la toma de corriente de pared en forma correcta No ponga a funcionar el equipo de aire acondicionado con una cubierta protectora exterior encima Esto podr a ocasionar da os mec nicos dentro del aire acondicionado No use un cable de extensi n ni un enchufe adaptador A ADVERTENCIA Evite los peligros de incendios y descargas el ctricas No use un cable de extensi n ni un enchufe adaptador No elimine ninguna de las espigas del enchufe del cord n de alimentaci n el ctrica Toma de corriente de pared con Cable de conexi n a tierra alimentaci n con clavija dotada de Prueba conexi n a tierra de 3 terminales Terminal de conexi n a tierra Reponga Bajo ninguna circunstancia corte quite o evite el uso de la conexi n a tierra de esta clavija IDEAS PARA AHORRAR ENERG A La capacidad del equipo de aire acondicionado debe corresponder al tama o de la habitaci n para el funcionamiento eficiente y satisfactorio del e
25. condicionado instalado por un t cnico en este tipo de instalaciones LA ELIMINACION DE LA VENTANA Apague y desenchufe el aire acondicionado Si ventana corredera horizontal retire la m nsula de Bloqueo de ventana de marco de la ventana y la franja de sellante de espuma entre las ventanas En caso de ventana corredera horizontal Retire la m nsula de seguridad que instal en el paso 12 Desatornille la cortina de marco de la ventana Retire el aire acondicionado de la abertura de la ventana TENGA CUIDADO DE NO DEJARLO CAER Una vez retirada col quelo de forma segura fuera de la v a Retire la cortina de marco y la cortina Desatomille las gu as laterales y la gu a superior Coloque la unidad y todo el equipo de ensamble en la caja de embarque del aire acondicionado y guarde en un lugar limpio y seco Persiana Lateral CUIDADO El aire acondicionado del que se habla en este manual afirma peligro de peso excesivo Dos o mas personas se requiere para mover e instalar la unidad Para evitar heridas o agotamiento use tecnicas apropiadas para levntar y mover la unidad Al manejar la unidad tenga cuidado para evitar cortarse con las alertas met licas afiladas que est n en los serpentines frontal y posterior Asegurese que el aire acondicionado no se caiga durante la instalacion 2092 OPERACI N C MO Y POR QU Su equipo de aire acondicionado de habitaci n brinda la
26. demasiado c lido Fije el control TEMP a una temperatura m s inferior Temperatura ambiente por debajo de los 70 F 21 C El enfriamiento puede no ocurrir hasta que la temperatura ambiente sea superior a 70 F 21 El conducto de detecci n de temperatura est en contacto con la bobina del evaporador ubicada tras la rejilla frontal Enderece el conducto lejos de la bobina de evaporador EL AIRE ACONDICIONADO ENFR A PERO EL CUARTO EST DEMASIADO C LIDO SE EST FORMANDO HIELO TR S LA REJILLA DE ENTRADA Compruebe si Despu s Temperatura ambiente por debajo de los 70 F 21 Para descongelar la bobina fije el MODO a VENTILADOR y la velocidad del ventilador a Alta El filtro de aire puede estar sucio Limpie el filtro de aire Consulte la secci n de mantenimiento en el manual del propietario Control TEMP fijado demasiado bajo Para descongelar la bobina fije el MODO a Cool la velocidad del ventilador a Alta y el contro TEMP a una temperatura mas alta EL AIRE ACONDICIONADO ENFR A PERO EL CUARTO EST DEMASIADO C LIDO Compruebe si Despu s Filtro de aire sucio aire restringido Limpie et filtro de aire Consulte la secci n de mantenimiento del manual del propietario EL control TEMP est fijado a demasiado caliente Fije el control de TEMP a una temperatura m s inferior La parte frontal de la unidad est bloquead
27. e inspeccione el lugar donde el aire acondicionado sera puesto Asegurese que el lugar sostenga el peso de la unidad sobre un periodo de tiempo prolongado Mantenga su aire acondicionado con cuidado Use guantes protectores cuando levante o mueva la unidad EVITE las aletas filosas de metal en el serpentin delantero y de atras Asegurese que el aire acondicionado no se caiga durante ta instalacion NOTE Antes de usar el acondicionador de aire asegure la parrilla delantera con dos tomillos incluidos con el manual de owner s 1 Abra la parrilla de la entrada hacia abajo y quite el filtro de aire 2 Sujete la parrilla delantera con los tornillos 3 Reinstale el filtro de aire 4 Cierre la parrilla de la entrada Bandejade Entrada 19 TONVdS4 INSTALACI N INSTALACI N PIEZAS DE INSTALACI N MONTAJE Escoja un lugar que le permita llevar el aire frio al rea que desea Las ventanas que se usen para la instalaci n deben tener la resistencia suficiente para soportar el peso del equipo de aire acondicionado Una buena instalaci n con atenci n especial a la correcta posici n de la unidad disminuir la probabilidad de que sea necesario efectuar reparaciones Cuando se desea enfriar m s de una habitaci n la instalaci n es muy importante puesto que el aire fr o no dobla esquinas Para enfriar sus habitaciones el aire frio debe desplazarse desde el equipo de aire acondicionado en
28. e on the top of the Air Conditioner using 3 Type A screws Fig 4 Fastening Side Guides Side Guide FIG 4 Measure height of window opening from top of Bracket assembly as shown Fig 5 Subtract 20 3 4 inches Mark this measurement on Curtain and cut the Curtain Fig 5 FIG 5 E Slide Curtain into Curtain Frame Slide Curtain Frame assembly into side Guides of the Air Conditioner cabinet Make sure Curtain is firmly enclosed on all sides by the Frame Fig 6 FIG 6 9 Cut side Guide seal into 2 equal lengths Remove protective backing and apply it to the rear side of cabinet Side Guides starting just below Curtain Frame assembly Pinch off excess length so seal is even with the bottom of side Guide Fig 7 Apply weather seal to side guides just below edge of Curtain Frame FIG 7 HSITDNA INSTALLATION Place Air Conditioner in window opening It should sit on Bracket assembly so that Curtain Frame and cabinet Side Guides are against top and side window jambs Mate front of Bracket with Base Guide attached to the bottom of base pan 11 Drill 4 8 inch holes in window track through the existing holes on Base Guide Screw 4 Type screws through the holes Fig 8 112 If this is a casement window installation proceed to Casement Window installation If not slide inner window sash firmly against side of the cabinet Dri
29. e permanece lleno de polvo el flujo de aire disminuir y se reducir la capacidad de enfriamiento del equipo con posibles da os para la unidad Figura 18 Abra la rejilla de entrada de aire hacia arriba tirando de la parte superior de esta rejilla Figura 18 Remueva el filtro de aire de la parrilla frontal haland el fitro suavemente hacia arribo Figura 19 FIG 20 FIG 18 C MO SACAR LA REJILLA FRONTAL Saque el tornillo que mantiene ta rejilla frontal en posici n Quite el tornillo que asegura le reja delantera Empuje la rejilla hacia arriba de abajo y jale la parte de arriba de la rejilla lejos de la base para levantar las lenguetas de arriba hacia afuera de las ranuras FIG 19 Entrada Entrada LIMPIEZA DEL EQUIPO DE AIRE ACONDICIONADO La rejilla frontal y la rejilla de entrada del aire pueden lavarse con un pa o humedecido en una soluci n de detergente suave El gabinete puede lavarse con un jab n o detergente suave y agua tibia seguidamente puede pulirse con cera liquida especial para electrodom sticos Para asegurar una eficiencia m xima continua los serpentines del condensador lado de enfrente de la unidad deben revisarse peri dicamente y limpiarse si est n obstruidos con holl n o con sucio de la atm sfera C MO A REEMPLAZA EL GRILLE ANTERIOR Pegue el panel frontal a la caja insertando los fijadores en el panel
30. ection Agreement puede ayudarle a ahorrar dinero e inconvenientes Adquiera un Master Protection Agreement ahora y prot jase a s mismo de molestias y gastos inesperados El Master Protection Agreement le ayudar tambi n a prolongar la vida de su nuevo aparato Los siguientes servicios est n incluidos Servicio experto por parte de cualquiera de nuestros 12 000 t cnicos profesionales especialistas de Sears Prestaci n de servicios sin limitaciones y sin cargarle las piezas o la mano de obra en todas las reparaciones cubiertas por el acuerdo Garant a seria de sustituci n de las piezas del producto cubierto por el acuerdo si cuatro o m s piezas se mostrasen defectuosas en un periodo de doce meses Sustituci n del producto por otro nuevo si el defectuoso no pudiese repararse Control de mantenimiento anual preventivo siempre que lo desee y sin gasto adicional alguno Asistencia telef nica inmediata de un t cnico especialista en productos que han de ser reparados a domicilio adem s de una programaci n adecuada de la reparaci n 7 Protecci n contra subidas de tensi n que provoquen da os el ctricos debidos a las fluctuaciones en el suministro Reintegro del alquiler si la reparaci n del producto lleva m s tiempo del promtetido Una vez que haya adquirido el Agreement no necesitar m s que una simple llamada para solicitar el servicio de su aparato Adem s podr hacerlo en cualquier momento del d a
31. erate heat producing appliances such as ranges washers dryers and dishwashers during ZARIE ELECTRICAL REQUIREMENTS OBSERVE ALL LOCAL CODES AND ORDINANCES DO NOT UNDER ANY CIRCUMSTANCES REMOVE THE POWER SUPPLY CORD GROUND PRONG ELECTRICAL GROUND IS REQUIRED ON THIS APPLIANCE For 230 208 volt 60 Hz AC only 15A fused and properly grounded electrical supply is required A time delay fuse or time delay circuit breaker is recommended Use a dedicated circuit serving only this appliance DO NOT USE AN EXTENSION CORD Use Wail Receptacle Standard 125V 3 wire grounding receptacle rated 15A 125V AC Use 15 AMP time delay fuse or 15 AMP Standard 250V circuit breaker 3 wire grounding receptacle rated 45A 250V AC Standard 250V 3 wire grounding receptacle rated 20A 250V AC Use 20 AMP time delay fuse or 20 AMP circuit breaker RECOMMENDED GROUNDING METHOD For your personal safety this appliance must be grounded This appliance has a power supply cord with a 3 prong grounding plug To minimize possible shock hazard the cord must be plugged into a mating grounding type wall receptacle and grounded in accordance with the National Electrical Code ANSI NFPA 70 latest edition and all local codes and ordinances lf a mating wall receptacle is not available it is the personal responsibility and obligation of the customer to have a properly grounded 3 prong wall receptacle installed by a qual
32. ified electrician Power cord may include a current interrupter device A test and reset button is provided on the plug case The device should be tested on a periodic basis by first pressing the TEST button and then the RESET button If the TEST button does not trip or if the RESET button will not stay engaged discontinue use of the air conditioner and contact a qualified service technician Electrical Shock Hazard Plug into a grounded 3 prong outlet Do not remove ground prong Do not use an adapter Do not use an extension cord Failure to follow these instructions can result in death fire or electrical shock INSTALLING THE POWER CORD You can choose between the two methods below according to your preference and window sill shape USING SLIT A Fasten the stopper using Type A screw and lead the power cord out through slit A USING SLIT B Fasten the stopper using left screw hole and rotate properly to lead the power cord out through slit B Screw Type A Power cord SS BaN N INSTALLATION INSTALLATION REQUIREMENTS These instructions are for a horizontal sliding or a casement window The electrical outlet must be within reach of the power cord Side louvers and the rear of the air conditioner must have clear air space to allow enough air flow through the condenser for heat remove The rear of the unit must be outdoors not inside a bu
33. ilding or garage Horizontal sliding window 454 min 16 Ve max Casement window ELECTRICAL SERVICE Check your available electrical service The power supply available must be the same as that shown on the unit nameplate found on right side of cabinet All models are equipped with a 3 prong service plug to provide proper service and safe positive grounding Do not change plug in any way Do not use an adapter plug If your present wall outlet does not match your plug call a qualified electrician to make the necessary corrections SAVE CARTON and this OWNER S MANUAL for future reference The carton is the best way to store unit during winter or when not in use A CAUTION To avoid risk of personal injury property damage or product damage due to the weight of this device and sharp edges that may be exposed Air conditioners covered in this manual pose an excessive weighi hazard Two or more people are needed to move and install the unit To prevent injury or strain use proper lifting and carrying techniques when moving unit Carefully inspect location where air conditioner will be installed Be sure it will support the weight of the unit over an extended period of time Handle air conditioner with care Wear protective gloves whenever lifting or carrying the unit AVOID the sharp metal fins of front and rear coils Make
34. l compartimento Taladre un agujero de 1 8 pulgadas para alinearlo con los agujeros que hay en el marco de la cortina Ajuste el marco de la cortina con el marco de la ventana con tornillos del tipo B Fig 8 NOTA Comprobar todas las juntas y sellar cualquier abertura de aire restante con un sellante aislante adecuado Basteja y ees 7 H 4 SySon io a Fipo B Tornillo Tipo Tornillo Banda de la ventana FIG 8 114 Si se trata de la instalaci n de una ventana de bisagras proceda seg n la Instalaci n de ventana de bisagras Colocar el burlete de espuma entre la banda vertical y el vidrio de la ventana Fig 9 Fijar el soporte de bloqueo de la ventana con un tornillo de tipo B Fig 9 Bande d tanch it en mouse Soporte de fijaci n de ventana FIG 9 INSTALACION DE VENTANA CON MARCO El proceso de montaje es el mismo proceso descrito en los pasos 1 a 11 y paso 13 de la instalaci n de ventana corredera horizontal Si el hueco de la ventana tiene una anchura superior a 15 3 4 pulgadas ser necesanrio colocar un panel de llenado Fabricar este panel con madera de un grosor de 3 4 de pulgada y con la longitud completa de la ventana Fijarlo ai marco de la ventana para protegerlo contra la intemperie A raiz de que los estilos y los tama os de la ventana del compartimiento var a ampliamente es aconsejable tener el aire a
35. ll 1 8 inch hole in window jamb to align with the existing holes in the Curtain Frame Attach Curtain Frame to window frame with 2 Type B screws Fig 8 NOTE Check all seals and plug any remaining air gaps with a suitable weatherproof caulk 5 Base pan Base i i K KS TYPES raw Window Track If this is a casement window installation proceed to Casement Window Installation If not stuff the Foam Seal Strip between the vertical sash and the window glass Fig 9 15 Attach the L Bracket with a Type B screw Fig 9 CASEMENT WINDOW INSTALLATION Installation procedure is the same as that described in steps 1 through 11 and step 13 of the Horizontal Sliding Window installation If the window opening is wider than 15 3 4 inches you will need to install a filler panel Make this panel from 3 4 inch thick wood and run it the full length of the window Attach it securely to the window frame and paint it to protect it from the weather Since there is a wide variety of casement window styles and sizes these instructions may not be exactly suited to your particular situation To ensure best results have the work performed by someone skilled in installing casement window air conditioners REMOVAL FROM WINDOW Turn off and unplug the air conditioner If horizontal sliding window remove the L Bracket from window frame and the Foam Seal Strip from between the windows Remove
36. load Unit is set to energy saver mode Approximately every 3 minutes the fan will turn on and the unit will check the room air temperature to determine if cooling is needed This is normal energy saver mode operation NOISE WHEN UNIT IS COOLING Check if Then Sound of fan hitting water from the moisture removal system This is normal when humidity is high Close doors windows and registers Window vibration poor installation Refer to installation instructions or check with installer WATER DRIPPING INSIDE ROOM WHEN UNIT IS COOLING Check if Then The air conditioner is improperly installed Tilt air conditioner slightly to the outside to allow water drainage Refer to installation instructions or check with installer WATER DRIPPING OUTSIDE WHEN UNIT IS COOLING Check if Then The unit is removing large quantities of moisture This is normal during excessively humid days from humid room 14 ENGLISH 15 INDICE DE MATERIAS INDICE DE MATERIAS 16 GARANT A rnei eect eee i e eien 16 SEGURIDAD rieien iae 47 importantes instrucciones de seguridad 17 REQUERIMIENTOS EL CTRICOS 18 INSTALACI N DEL CABLE EL CTRICA 18 INSTALACI N eee 19 Requistios de ventana r 19 o sieieie enes 20 Montaje en una ventana de corredera DOTIZONtal Serres 20 instalacion de ventana con marco 22 La eliminacion de la ventana eee es 22 OPERACI N
37. n las siguientes Aseg rese de que la alimentaci n el ctrica sea la apropiada para el modelo que usted ha elegido Si el equipo de aire acondicionado debe instalarse en una ventana a usted probablemente le conviene limpiar primero ambos lados del vidrio Si la ventana es del tipo de tres paneles con un panel incluido de pantalla le conviene sacar la ventana completamente antes de la instalaci n Aseg rese de que el equipo de aire acondicionado ha sido instalado correctamente y con seguridad seg n se se ala en las instrucciones separadas de instalaci n que vienen en este manual Conserve este manual y las instrucciones de instalaci n para usarlos posiblemente en el futuro al sacar o volver a instalar esta unidad Use guantes al manejar el equipo de aire acondicionado tenga cuidado para evitar cortadas con las afiladas aletas met licas que se hallan en los serpentines frontales y posteriores WEBS INFORMACI N ELECTRICA En la placa de serie del fabricante se indica cu l es la capacidad el ctrica nominal completa de su nuevo equipo de aire acondicionado para habitaci n Consulte esta placa cuando vaya a verificar los requerimientos el ctricos Aseg rese de que el equipo de aire acondicionado tenga una conexi n correcta a tierra Para reducir al m nimo los riesgos de descargas el ctricas e incendio es importante conectar el equipo correctamente a tierra El cord n de alimentaci n el ctrica est equipado
38. nstalado incorrectamente Incline el aire acondicionado levemente hacia el exterior para permitir el drenaje del agua Consulte las instrucciones de instalaci n o consulte con el instalador GOTEO DE AGUA EN EL EXTERIOR CUANDO LA UNI Compruebe si DAD EST ENFRIANDO Despu s La unidad est eliminando grandes cantidades de Esto es normal durante los d as excesivamente h medos humedad de un cuarto h medo 28 NOTA ESPA OL 29 NOTA Master Protection Agreements Congratulations on making a smart purchase Your new Kenmore product is designed and manufactured for years of dependable operation But like all products it may require preventive maintenance or repair from time to time That s when having a Master Protection Agreement can save you money and aggravation Purchase a Master Protection Agreement now and protect yourself from unexpected hassle and expense The Master Protection Agreement also helps extend the life of your new product Here s what s included in the Agreement Expert service by our 12 000 professional repair specialists Unlimited service and no charge for parts and labor on all covered repairs mM No lemon guarantee replacement of your covered product if four or more product failures occur within twelve months Y Product replacement if your covered product can t be fixed Annual Preventive Maintenance Check at your request
39. o Broca de taladro de 1 4 AN ee Banda de la ventana wg 20 INSTALACI N 4 Coloque la sujeci n del soporte contra la pared exterior y apriete los tornillos en la parte superior del soporte Ajuste los tornillos de nivelaci n de forma que el aire acondicionado quede instalada con una inclinaci n muy suave unos 1 4 hacia abajo hacia la salida para que drene correctamente Apriete la tuerca Fig 3 NOTA NO taladrar un agujero en la parte inferior de la bandeja de la base El aire acondicionado ha sido dise ado para funcionar con la bandeja de la base llena coh agua aproximadamente hasta la mitad de su capacidad unos 1 4 47 5 Sujete las gu as laterales a los laterales del aire acondicionado con tres tornillos del tipo A para las gu as Comience con el primer tornillo en la parte media de las gu as Fig 4 G Fijar la gu s superior en la parte superior del aparato de aire acondicionado usando 3 tornillos del tipo A Fijar las gu as laterales Guis lateral Guide lat ral FIG 4 Medir la altura de la abertura de la ventana desde la parte superior del soporte seg n se muestra en la Fig 5 Restar 20 3 4 pulgadas Marcar esta medida en la cortina y cortar la cortina Fig 5 FIG 5 8 Deslizar la cortina en la cortina del marco con el lado m s suave hacia la habita
40. o debido a la movimiento del deficiente construcci n TONVdS4 Condensador Usted puede escuchar gotas de agua que caen sobre el condensador causando un sonido met lico o un sonido de chasquido FIG 10 23 OPERACI N CARACTER STICAS USO DEL EQUIPO DE AIRE ACONDICIONADO Para reducir el riesgo de incendio descargas el ctrica o lesiones personales lea las IMPORTANTES INSTRUCCIONES DE SEGURIDAD antes de operar este aparato Para comenzar a utilizar el equipo de aire acondicionado siga estos pasos 1 Enchufe el equipo de aire acondicionado Para prevenir riesgos de descargas el ctricas no use un cable de extensi n ni un enchufe adaptador 2 Ajuste el extractor de aire en la posici n CLOSE 3 Ajuste el control de MODE al mas alto nivel fresco 4 Ajuste el control del ventilador al m s alto nivel 5 Ajuste las rejillas desviadoras para lograr un flujo confortable de aire 6 Una vez que la habitaci n se haya enfriado ajuste el control de temperatura TEMP a la graduaci n que usted considere m s confortable NOTA Si se apaga el aire acondicionado espere 3 minutos antes de volver a encenderlo Esto permite que se estabilice la presi n dentro del compresor Si no sigue estas instrucciones el equipo podr a funcionar con poca eficiencia Si usted mueve el TEMP el control a un warmer entonces inmediatamente espalda a una
41. oom temperature below 70 F 21 C Cooling may not occur until room temperature rises above 70 F 21 C Temperature sensing tube touching evaporator coil Straighten tube away from evaporator coil located behind front grille THE AIR CONDITIONER COOLING BUT ROOM IS TOO WARM ICE FORMING ON COOLING COIL BEHIND INLET GRILLE Check if Then Outdoor temperature below 70 F 21 C To defrost the coil set the MODE to FAN FAN speed to High Air filter may be dirty Clean air filter Refer to Maintenance section of owner s manual To defrost the coil set the MODE to Cool Fan speed to high and the TEMP Control set too low Temp control to a higher temperature THE AIR CONDITIONER COOLING BUT ROOM IS TOO WARM Check if Then Dirty air filter air restricted Clean air filler Refer to Maintenance section of owner s manual TEMP Control set too warm Set TEMP Control to a lower temperature Front of unit is blocked by drapes blinds furniture etc Clear blockage in front of unit Air distribution is restricted Doors windows registers ete open Cold air escapes Close doors windows registers etc Unit recently turned on in hot room Allow additional time to rernove stored heat from walls ceiling floor and furniture THE AIR CONDITIONER TURNS ON AND OFF RAPIDLY Check if Then Outside temperature is extremely hot Set FAN SPEED on HI to minimize the cooling
42. otones funcionamiento Cuando lo enciende por primera vez el aire Saque las baterias dei control remoto si no va a utilizar el acondicionado esta en el modo de enfriamiento mas alto aire acondicionado por un periodo prolongado y la temperatura en 72 F Para evitar el descargue remueva las pilas del control remoto si el aire acondicionado no va a ser usado por un 2 AJUSTE DE TEMPERATURA per odo extendido de tiempo Mantenga el control remoto Use este bot n para controlar autom ticamente la alejado de lugares de extramo calor o humedad Para temperatura La temperatura puede ajustarse dentro de mantener la operaci n ptima del control remoto el sensor un rango de 60 F a 86 F de 1 F del remoto no debe ser expuesto al rayo solar directo 3 MODO El control remoto puede ser colocado sobre una pared Cada vez que oprime este bot n cambiar entre COOL usando el soporte montable ENERGY SAVER y FAN ENFRIAMIENTO AHORRO DE ENERGIA y VENTILADOR AHORRO DE ENERG A El ventilador se detiene cuando el compresor deja de enfriar Aproximadamente cada 3 minutos el ventilador se encender y se verificar la temperatura de la habitaci n para ver si es necesario enfriar 26 MAINTENANCE LIMPIEZA DEL FILTRO DEL AIRE El filtro del aire se ira ensuciando a medida que va atrapando el polvo proveniente del aire interior Es preciso lavar el filtro del aire al menos cada dos semanas Si el filtro del air
43. quipo Instale el equipo de aire acondicionado de habitaci n en el lado sombreado de su hogar Una ventana orientada hacia el norte es la mejor porque tiene sombra la mayor parte del d a No bloquee el flujo de aire hacia el interior con persianas cortinas o muebles o la parte de afuera con arbustos paredes u otras construcciones Cierre el regulador de tiro de la chimenea las rejillas de calefacci n del piso y la pared de tal modo que el aire frio no se escape ni por la chimenea ni por los conductos Mantenga las persianas y las cortinas de otras ventanas cerradas durante la parte m s soleada del d a Limpie el filtro del aire como se recomienda en la secci n MANTENIMIENTO de este manual El aislamiento correcto y las juntas herm ticas en puertas y ventanas en su hogar le ayudar n a mantener el aire caliente afuera y el aire frio adentro Al darle sombra externamente a la casa con rboles plantas o toldos ayudar a reducir la carga de trabajo del equipo de aire acondicionado Opere los aparatos que producen calor como por ejemplo hornos lavadoras secadoras y lavaplatos durante la parte m s fr a del dia 17 TONVdS4 REQUERIMIENTOS EL CTRICOS RESPETE TODOS LOS C DIGOS Y REGLAMENTOS M TODO RECOMENDADO DE CONEXI N A TIERRA BAJO NINGUNA CIRCUNSTANCIA CORTE QUITE O Por su propia seguridad este aparato debe conectarse a tierra Este EVITE EL USO DE LA CONEXI N A TIERRA DE ESTA ap
44. rry in items like vacuums lawn equipment and electronics call or go on line for the location of your nearest Sears Parts amp Repair Center 1 800 488 1222 Call anytime day or night U S A only WWw sears com To purchase a protection agreement U S A or maintenance agreement Canada on a product serviced by Sears 1 800 361 6665 Canada Para pedir servicio de reparaci n Au Canada pour service en francais a domicilio y para ordenar piezas 1 800 LE FOYER 1 888 SU HOGAR 1 800 533 6937 1 888 784 6427 WWW sears ca Registered Trademark Trademark MM Service Mark of Sears Brands LLC Marca Registrada Marca de F brica Marca de Servicio de Sears Brands LLC MC Marque de commerce MO Marque d pos e de Sears Brands LLC Sears Brands LLC Part No 3828A21007N
45. s The air then passes over a cooling coil which refrigerates the air and removes excess moisture The same air is then returned to the room cooler drier and cleaner Moisture removed from the room air is carried to the outside and evaporated Your air conditioner is designed to be easy to operate and to provide plenty of cooling power HSIMONA NORMAL SOUNDS Fic 10 Aside from the regular fan motor and compressor sounds coming from your air conditioner you will once ina while hear a pinging sound This is the result of moisture being picked up from the air in the room and thrown against the air conditioner s fan This is normal and should not be cause for concern Condenser Also do not be alarmed if you hear a slight hissing You may hear droplets of water hitting or gurgling sound coming from your air conditioner the condenser causing a pinging or after it is off These are normal coolant noises clicking sound FIG 10 CAPACITY AND RUNNING TIME Proper unit size is important in deciding the desired comfort for the area you want to cool An undersized unit will not have the capability to cool leaving the area uncomfortably warm The proper size is determined by the number of square feet in the area to be cooled indoor and outdoor temperature and humidity Whenever the heat or humidity load is above normal the air conditioner must run longer and more often to keep the desired tempera
46. s siguientes funciones para hacer que la vida en climas c lidos sea m s confortable Enfr a y hace circular el aire por la habitaci n Disminuye la humedad eliminando la humedad excesiva Filtra el polvo el sucio y algunas impurezas transportadas en el aire del clima veraniego El equipo de aire acondicionado realiza estas funciones haciendo pasar el aire del medio ambiente a trav s de un filtro que atrapa las part culas de polvo y sucio El aire pasa entonces por un serpent n de enfriamiento que refrigera el aire y elimina el exceso de humedad El mismo aire regresa entonces al enfriador secador y limpiador del aire del ambiente La humedad extra da del aire ambiente es llevada al exterior y evaporada Su aire acondicionado est dise ado para operar y suministrar una enorme potencia de enfriamiento SONIDOS NORMALES Figura 10 Adem s de los sonidos regulares del motor del ventilador y el compresor que salen de su equipo de aire acondicionado usted escuchar de vez en cuando un sonido met lico Este sonido es producido por la humedad que es recogida del aire en el ambiente y es lanzada contra el ventilador del equipo de aire acondicionado Esto es algo normal que no debe ser motivo de preocupaci n De igual modo no se alarme si usted escucha un ligero sonido de silbido o borboteo proveniente de su equipo de aire acondicionado despu s que lo apaga Estos son ruidos normales del refrigerante CAPACIDAD Y TIEM
47. tema de refrigeraci n herm ticamente sellado que consiste en el agente refrigerante los tubos de conexi n y el compresor si tiene alg n defecto en materiales o fabricaci n EL SERVICIO DE GARANT A EST A SU DISPOSICION CON SOLO PONERSE EN CONTACTO EL CENTRO DE SEARS AL 1 300 4 MY HOME La proteccion de garant a cubre unicamente a los equipos de aire acondicionado usados para uso domestico y ho para uso comercial Esta garant a s lo tiene validez mientras el producto se est usando en los Estados Unidos Esta garant a le da derechos legales espec ficos y usted puede tener otros derechos que var an de estado en estado Distributed by Sears Roebuck and Co Hoffman Estates IL 60179 16 SEGURIDAD IMPORTANTES INSTRUCCIONES DE SEGURIDAD Las siguientes instrucciones de seguridad le indicar n c mo usar su equipo de aire acondicionado de habitaci n para evitar da os para usted mismo y para su EQUIPO DE AIRE ACONDICIONADO EU POR SU SEGURIDAD No almacene ni use gasolina u otros vapores y l quidos inflamables cerca de ste o cualquier otro electrodom stico Lea las etiquetas de los productos para ver si contienen advertencias sobre el car cter inflamable de los mismos y otras advertencias AA ADVERTENCIA PARA PREVENIR ACCIDENTES Para reducir el riesgo de incendios descargas el ctricas o lesiones personales al usar su equipo de aire acondicionado tome las precauciones b sicas entre las que est
48. the Safety Bracket that you installed in Step 12 Unscrew the Curtain Frame from the window frame Remove air conditioner from the window opening BE CAREFUL NOT TO DROP IT Once removed set it safely out of the way Remove Curtain Frame and Curtain Unscrew the Side Guides and Upper Guide Place unit and all assembly hardware in air conditioner shipping carton and store in a clean dry place CAUTION Air conditioners covered in this manual pose an excessive weight hazard Two or more people are needed to move and install the unit To prevent injury or strain use proper lifting and carrying techniques when moving unit When handling the air conditioner be careful to avoid cuts from sharp meial fins on front and rear coils Make sure air conditioner does not fall during removal OPERATION HOW AND WHY Your room air conditioner provides the following aoe Compressor functions to make hot weather living more fortable The modern high efficiency none compressor may have a high Cools and circulates room air pitched hum or pulsating Lowers humidity by removing excess moisture nee may cycles onand off Filters out summertime dust dirt and some es Unit Vibration airborne impurities Fan The unit may vibrate The air conditioner performs these functions by You may hear air ae make sess 1 drawing room air through a filter which traps dust ag trom nde nea and dirt particle
49. time delay fuse or circuit breaker have a qualified electrician install the proper receptacle Do not run air conditioner with a protective covering This could result in mechanical damage within the air conditioner Do not use an extension cord or an adapter plug FTE el Avoid fire hazard or electric shock Do not use an extension cord or an adapter plug Do not remove any prong from the power cord 3 prong grounding Y 3 prong plug grounding type wall receptacle Test Ground ron Reset ld Power supply cord ENERGY SAVING IDEAS The capacity of the room air conditioner must fit the room size for efficient and satisfactory operation Install the room air conditioner on the shady side of your home A window that faces north is best because it is shaded most of the day Do not block air flow inside with blinds curtains or furniture or outside with shrubs enclosures or other buildings Close the floor and wall registers and the fireplace damper so cool air does not escape up the chimney and into the duct work Keep blinds and drapes in other windows closed during the sunniest part of the day Clean the air filter as recommended in the MAINTENANCE Section of this manual Proper insulation and weather stripping in your home will help keep warm air out and cool air in External house shading with trees plants or awnings will help reduce the air conditioner s work load Op
50. tions are correct Be sure that both batteries are new 3 Re attach the cover REMOTE CONTROL OPERATIONS 1 POWER To turn the air conditioner ON push this button To turn the air conditioner OFF push the button again This button takes priority over any other button When you first turn it on the unit is in cool mode High fan speed Temperature setting at 72 F 2 TEMPERATURE SETTING Use this button to automatically control the temperature of the room The temperature can be set within a range of 60 F to 86 F by increments of 1 F 3 MODE Every time you push this button it will shift among COOL ENERGY SAVER and FAN ENERGY SAVER The fan stops when the compressor stops cooling Approximately every 3 minutes the fan will turn on and the unit will check the room air to determine if cooling is needed 4 FAN SPEED Every time you push this button it advances the setting as follows High F3 gt Low F1 gt Med F2 High F3 Do not use rechargeable batteries Such batteries differ from standard dry cells in shape dimensions and performance Remove the batteries from the remote controller if the air conditioner is not going to be used for an extended length of time in order to prevent discharge remove the batteries from the remote control if the air conditioner is not going to be used for an extended pericd of time Keep the remote control away from extremel
51. ture you have selected Under heavy heat load conditions the air conditioner may need to run constantly to keep the temperature you want At times using the MED FAN setting to circulate the room air may make it comfortable even though the air is not being cooled This will decrease your cost of use OPERATION FEATURES USING THE AIR CONDITIONER FIG 11 AAWARNING To reduce the risk of fire electric shock or injury to persons read the important SAFETY instructions section before operating this appliance To begin operating the air conditioner after installation follow these steps 1 Plug in the air conditioner To prevent electrical hazards do not use an extension cord or an adapter plug Set the exhaust vent to the CLOSE position Set the TEMP Control to the coolest setting Set the MODE contro at the highest COOL level Adjust the louvers for comfortable air flow Once the room has cooled adjust the TEMP and Made Control to the setting you find most comfortable QO AUN NOTE If the air conditioner is turned off wait 3 minutes before restarting This allows pressure inside the compressor to equalize Failure to wait 3 minutes before restarting may cause inefficient operation if you move the TEMP Control to a warmer then immediately back to a cooler setting the unit will shut off Wait 3 minutes before restarting
52. un Standard 250V interruptor de 15AMP enchufe de 3 L neas de Peligro de choque el ctrico 15A 250V AC Conecte en una conexi n de pared de 3 terminales No quite la termina de conexi n a tierra a y No use adaptadores Utilice un fusible de gs vh enchufe de 3 20AMP o un No use cable el ctrico de extensi n Lineas de interruptor de 20AMP Si no se siguen estas instrucciones puede ocasionarse 20A 250V AC eee la muerte un incendic o un choque el ctrico INSTALACI N DEL CABLE EL CTRICA Puede escoger entre los dos m todos abajo descritos de acuerdo a la forma del taburete de su ventana y su preferencia Standard 250V UTILIZANDO LA RANURA A UTILIZANDO LA RANURA B Aprete el obturador usando hoyo de tornillo y saque Aprete el obturador usando el hoyo izquierdo de el cable el ctrico a trav s de la ranura A tornillo y gire apropiadamente para sacar el cable el ctrico a trav s de la ranura B VA A Tornillo tipo A O Cable de conexi n el ctrica 18 INSTALACI N REQUISTIOS DE VENTANA Estas instrucciones son para una ventana de corredera horizontal o un marco de ventana La salida el ctrica debe quedar al alcance del cable de conexi n Para la instalaci n en una ventana con marco la estructura de la ventana y el lateral del edificio deben ser los adecuados para soportar el peso del aparato de aire acondicionado
53. y hot or humid places To maintain optimal operation of the remote control the remote sensor should not be exposed to direct sunlight The remote control can be mounted on a wall using the mountable holder 12 MAINTENANCE AIR FILTER CLEANING The Air Filter will become dirty as it removes dust from the inside air lt should be washed at least every 2 weeks If the Air Filter remains full of dust the air flow will decrease and the cooling capacity will be reduced possibly damaging the unit Pull the inlet grille forward grasping both tabs then pull out the air filter FIG 18 Wash the Air Filter under the faucet with warm water Be sure to shake off all the water before replacing the filter FIG 19 FIG 20 FIG 18 HOW TO REMOVE THE FRONT GRILLE Open the inlet grille downward Remove the screw securing the Front Grille e Push the grille up from the bottom and pull the top of the grille away from the case to lift the top tabs out of their slots FIG 19 Front Grille FIG 21 AIR CONDITIONER CLEANING Clean the front grille and inlet grille by wiping with a cloth dampened in a mild detergent solution FIG 20 The cabinet may be washed with mild soap or detergent and lukewarm water then polished with liquid appliance wax To ensure continued peak efficiency the condenser coils outside of the unit should be checked