Home

Juniper Networks M120 User's Manual

image

Contents

1. g003905 Center MultiServices 500 PIC Software release 80 mm MultiServices PICs MultiServices PICs m MultiServices 100 JUNOS 8 2R2 and later Type 1 NOTE This PIC requires the 710 017980 version of the FPC1 MultiServices 400 JUNOS 8 2 and later Type 2 MultiServices 500 JUNOS 8 3 and later Type 3 Description m Supports tunnel services This feature is included with the PIC and does not require an individual license Individual licenses must be purchased for additional services Power requirement m Type 1 0 52 A 48 V 25 W m Type 2 0 69 A 48 V 33 W m Type 3 0 83 A 48 V 40 W Hardware features m Active monitoring on m Type 1 up to 1 6 million flows m Type 2 up to 3 2 million flows m Type 3 up to 3 2 million flows Software features m Support for up to 2000 service sets m Support for MTUs up to 9192 bytes for Gigabit Ethernet and SONET interfaces Depending on your JUNOS release and individual licenses software features for this PIC can include the features listed in Table 24 on page 81 For more information about the software features available for services PICs see the JUNOS Services Interfaces Configuration Guide LEDs Status LED one tricolor m Off PIC is offline and it is safe to remove it from the chassis m Green PIC is operating normally m Amber PIC is initializing m Red PIC has an error or failure and no further har
2. 1480 VHDCI to RJ 21 Cable Software release 4 port JUNOS 8 0R2 and later Type 1 8 port JUNOS 8 0R2 and later Type 1 12 port JUNOS 8 0R2 and later Type 1 48 port JUNOS 8 0R2 and later Type 2 NOTE These PICs are not supported in JUNOS Release 8 1R1 Description 4 100Base TX ports 8 100Base FX ports 12 100Base TX ports 48 100Base TX ports Power requirement m 4port 0 14 A 48 V 6 8 W m 8port 0 26 A 48 V 12 5 W m 12 port 0 23 A 48 V 11 W m 48 port 0 69 A 48 V 33 3 W Hardware features High performance throughput on each port at speeds up to 100 Mbps Source and destination Media Access Control MAC address filtering RMON EtherStats packet buffering 802 3 Ethernet standard compliant 4 port PICs support MTUs of up to 9 192 bytes 8 port 12 port and 48 port PICs support MTUs of up to 1 532 bytes 4 port PICs support 1 024 802 1Q VLANs per port 8 port 12 port and 48 port PICs support 16 802 1Q VLANs per port Software features Autosensing full duplex and half duplex modes Virtual Router Redundancy Protocol VRRP 802 1q virtual LANs VLANs Circuit cross connect CCC VLAN Fast Ethernet PICs mm 57 M120 Internet Router PIC Guide Cables and connectors 4 port PIC m Connector Two pair Category 5 unshielded twisted pair connectivity through an RJ 45 connector L Pinout MDI noncrossover 8 port PIC m Connector MT RJ fem
3. Virtual tunnel interface for Layer 3 VPNs 8 2R2 8 2 8 3 Layer 2 Tunneling Protocol L2TP 8 2R2 8 2 8 3 Voice services 8 2R2 8 2 8 5 m Compressed Real Time Transport Protocol CRTP Encapsulations 8 2R2 8 2 8 3 Multilink Frame Relay MLFR E Multilink Point to Point Protocol MLPP 82 W MultiServices PICs SONET SDH OC3c STM1 PIC SONET SDH OC3c STM1 PIC So5c560 E 1386 Software release JUNOS 8 0R2 and later Type 1 NOTE Although the illustration shows a multimode PIC a multimode PIC and a single mode intermediate reach PIC are both supported NOTE This PIC is not supported in JUNOS Release 8 1R1 Description m Four OC3 ports Power requirement 0 49 A 48 V 23 7 W Hardware features m Multiplexing and demultiplexing m Rate policing on input m Rate shaping on output m Packet buffering Layer 2 parsing Software features m SONET SDH framing m Link aggregation m Alarm and event counting and detection m Dual router automatic protection switching APS m Multiprotocol Label Switching MPLS fast reroute m Encapsulations E High Level Data Link Control HDLC Frame Relay Circuit cross connect CCC Translational cross connect TCC Point to Point Protocol PPP SONET SDH OC3c STM1 PIC 83 M120 Internet Router PIC Guide Cables and connectors m Duplex SC PC connector Rx and Tx m Optical interface support See Table 25 on page 85
4. Description m Four DS3 ports Power requirement 0 47 A 48 V 22 5 W ntegrated DSU interoperability with leading DSU vendors Hardware features High performance throughput on each port at speeds up to 44 736 Mbps full duplex C bit framing B3ZS line encoding Subrate and scrambling m Digital Link m Kentrox m Larscom Per port rate policing on input Per port rate shaping on output Packet buffering Layer 2 parsing 48 wm DS3PIC Software features DS3 PIC DS3 functionality a C bit framing m B3ZS line encoding DS3 diagnostics and loopback control DS3 alarm and event counting and detection Per packet counts and byte counts Local and remote loopback testing as well as BERT testing per DS3 DS3 far end alarm and control FEAC channel support Encapsulations a High Level Data Link Control HDLC Frame Relay E E Circuit cross connect CCC E Point to Point Protocol PPP Cables and connectors Custom 10 ft 3 05 m posilock SMB to BNC male cable separate Rx and Tx provided LEDs One tricolor per port Off Not enabled Green Online with no alarms or failures Amber Online with alarms for remote failures Red Active with a local alarm router has detected a failure Alarms errors and events Alarm indication signal AIS Bit error rate test BERT functionality on PIC you can configure one DS3 channel in BERT mode and configure the remaining channels to transmit a
5. 8 2 Ethernet IQ2 PICs Gigabit Ethernet IQ2 SFP 4 PB 4GE TYPE1 SFP IQ2 8 0R2 Gigabit Ethernet IQ2 SFP 8 PB 8GE TY PE2 SFP IQ2 8 0R2 Gigabit Ethernet IQ2 SFP 8 PC 8GE TYPE3 SFP IQ2 8 5 Services PICs Adaptive Services II AS 0 PB AS2 8 0R2 Adaptive SETVI ES ASY lay ene 0 PB AS2 LAYER2SERVICES 8 0R2 3 z Services Adaptive Services II AS FIPS 0 PB AS2 FIPS 8 0R2 10 PIC FPC Compatibility Table 6 M120 PIC FPC Compatibility continued PIC FPC Compatibility PIC Type Number of Ports PIC Model Number FPC1 FPC2 FPC3 MultiServices 100 NOTE This PIC requires the 0 PB MS 100 1 8 2R2 g 710 017980 version or later of the FPC1 MultiServices 400 0 PB MS 400 2 8 2 MultiServices 500 0 PC MS 500 3 8 3 Tunnel Services 0 PB TUNNEL 1 8 0R2 Tunnel Services 0 PB TUNNEL 8 0R2 Tunnel Services 0 PC TUNNEL 8 0R2 SONET SDH PICs OC3c STM1 PB 40C3 SON MM 4 8 0R2 PB 40C3 SON SMIR OC3 STM1 Multi Rate SFP 4 PB 40C3 10C12 SON SFP 8 4 OC3 STM1 Multi Rate SFP 4 PB 40C3 1OC12 SON2 SFP 8 3 OC12c STM4 PB 10C12 SON MM 1 8 0R2 PB 10C12 SON SMIR OC12 STM4 Multi Rate SFP 1 PB 1OC12 SON SFP 8 4 OC12 STM4 Multi Rate SFP 4 PB 40C3 40C1 2 SON SFP 8 3 OC48c STM16 4 PC 40C48 SON SFP 8 0R2 OC48 STM16 Multi Rate SFP 1 PB 1OC48 SON B SFP 8 3 OC192c STM64 XFP 1 PC 10C192 SON XFP 8 3 PIC FPC Compatibility m
6. ATM2 0C48 STM16 IQ PIC with SFP mg 31 M120 Internet Router PIC Guide 32 Em Table 11 Optical Interface Support for ATM2 IQ OC48 PICs continued PIC Type Single Mode Intermediate Reach Standard Maximum distance Transmitter wavelength Average launch power Receiver saturation Receiver sensitivity Telcordia GR 253 9 3 miles 15 km 1274 through 1356 nm 15 through 8 dBm 8 dBm 28 dBm ATM2 0C48 STM16 IQ PIC with SFP Channelized DS3 IQ PIC Channelized DS3 IQ PIC ee Channelizey DS3 KO STATUS TX g003037 Software release m JUNOS 8 0R2 and later Type 1 NOTE This PIC is not supported in JUNOS Release 8 1R1 Description Four DS3 ports Power requirement 0 32 A 48 V 15 6 W Intelligent queuing IQ PICs support fine grained queuing per logical interface Channelization DS3 DSO Hardware features m Data service unit DSU functionality Subrate and scrambling a Digital Link Quick Eagle Kentrox Larscom ADTRAN Verilink B3ZS line encoding M13 or C bit parity Full bit error rate test BERT Local and remote loopback testing Channelized DS3 IQ PIC m 33 M120 Internet Router PIC Guide Software features C Quality of service QoS per channel weighted round robin WRR random early detection RED weighted random early detection WRED Simple Network Management Protocol SNMP DS1 MIB DS3 MIB Dynamic arbitrary channel configur
7. BERR SD Bit error rate signal fail BERR SF Bit interleaved parity BIP error B1 Bit interleaved parity BIP error B2 Bit interleaved parity BIP error B3 Loss of frame LOF Loss of pointer HP LOP Loss of signal LOS Multiplex section remote error indication MS RE I Higher path label mismatch HP PLM Higher path unequipped HP UNEQ Multiplex section remote defect indication MS RDI Higher path remote defect indication HP RDI Errored seconds ES S ES L ES P far end errored seconds ES LFE ES PFE far end severely errored seconds SES LFE SES PFE far end unavailable seconds UAS LFE UAS Seve PFE ely errored framing SEF severely errored framing seconds SEFS S severely errored seconds SES S SES L SES P unavailable seconds UAS L UAS P Table 25 Optical Interface Support fo r SONET SDH OC3c STM1 PICs Parameter Intermediate Reach Multimode Optical interface Single mode Multimode Transceiver type Fixed Fixed SONET SDH OC3c STM1 PIC mf 85 M120 Internet Router PIC Guide Table 25 Optical Interface Support for SONET SDH OC3c STM1 PICs continued Parameter Intermediate Reach Multimode Standard Telcordia GR 253 Multivendor agreement Maximum distance SMF cable 9 3 miles 15 km MMF cable 1 2 miles 2 km Transmitter 1260 through 1360 nm 1270 through 1380 nm wavelength Average launch power 15 through 8 dBm Receiver saturation 8 dBm Receiver sensitivi
8. Optical Interface Support for Gigabit Ethernet PICs with SFP Parameter 1000Base SX 1000Base LX 1000Base LH Optical interface Multimode Single mode Single mode Transceiver type SFP SFP SFP Maximum distance Transmitter wavelength Average launch power Average receive power Receiver saturation Receiver sensitivity 62 5 125 MMF cable 656 ft 200 m 50 125 MMF cable 1640 ft 500 m 770 through 860 nm 9 5 through 0 dBm 17 through 0 dBm 0 dBm 17 dBm 9 125 SMF cable 6 2 miles 10 km 62 5 125 and 50 125 MMF cable 1804 5 ft 550 m 1270 through 1355 nm 11 5 through 3 dBm 19 through 3 dBm 3 dBm 19 dBm 9 125 SMF cable 43 5 miles 70 km 1355 through 1580 nm 3 through 3 dBm 20 through 3 dBm 3 dBm 20 dBm 62 um Gigabit Ethernet PICs with SFP Gigabit Ethernet IQ PICs with SFP Gigabit Ethernet IQ PICs with SFP pi mm Ni i in I Oo Ethernet 1000BASE X SFP PORT 4 SINS hee Oue 0 oO _ PORTO a STAUS Cien US lewn Quay 0 0 a a fe Ua athe ll g003092 Left 1 port Gigabit Ethernet IQ PIC Right 2 port Gigabit Ethernet IQ PIC Software release 1 port JUNOS 8 0R2 and later Type 1 2 port JUNOS 8 0R2 and later Type 2 NOTE These PICs are not supported in JUNOS Release 8 1R1 Description m One or two Gigabit Ethernet ports m Power requirement 0 46 A 48 V 22 W m Intellige
9. Out of frame OOF Yellow alarm bit A bit disagreements Instrumentation counters Layer 2 per queue packet and byte counters E3IQPIC mgm 53 M120 Internet Router PIC Guide EIA 530 PIC g003046 Software release m JUNOS 8 0R2 and later Type 1 NOTE This PIC is not supported in JUNOS Release 8 1R1 Description m Two EIA 530 X 21 or V 35 serial ports Power requirement 0 07 A 48 V 3 4 W Hardware features Configured as data terminal equipment DTE ports Resynchronization signal Receives clock rates up to 16 Mbps Local data communications equipment DCE local and DTE remote loopbacks 54 Em EIA 530 PIC Software features EIA 530 PIC Supports four queues per port Random early detection RED Transmitter Signal Element Timing is looped from the timing received on the Transmitted Signal Element DCE EIA 530 ports support the ability to invert the Transmit Data Element The EIA 530 ports support the following rates 2 048 Mbps 2 341 Mbps 2 731 Mbps 3 277 Mbps 4 09 Mbps 5 461 Mbps 8 192 Mbps 16 384 Mbps V 35 ports support up to 2 048 Mbps X 21 ports support up to 10 Mbps Encapsulations E High Level Data Link Control HDLC Frame Relay Circuit cross connect CCC Translational cross connect TCC Point to Point Protocol PPP Cables and connectors Two DB 25 male connectors one per port included with PIC V 35 requires an EIA
10. WRR random early detection RED weighted random early detection WRED SNMP T1 MIB and DSO MIB Dynamic arbitrary channel configuration Full bit error rate test BERT patterns at T1 and DSO levels Encapsulations E High Level Data Link Control HDLC Frame Relay Circuit cross connect CCC Translational cross connect TCC Point to Point Protocol PPP Cables and connectors m 20 ohm RJ 48C connector female LEDs On o tricolor per port Off Not enabled Green Online with no alarms or failures Amber Online with alarms for remote failures Red Active with a local alarm router has detected a failure 46 Channelized T1 IQ PIC Channelized T1 IQ PIC Alarms errors and m Alarm indication signal AIS events m Remote defect indication RDI Loss of frame LOF m Loss of signal LOS L Bipolar violation BPV E Excessive zero EXZ m Line code violation LCV m Error seconds ES m Severely errored seconds SES m Severely errored frames SEF L Bit error event BEE Instrumentation Layer 2 per queue and per channel packet and byte counters counters m 24 hour history or error counter updated at 15 minute intervals Channelized T1 IQ PIC m 47 M120 Internet Router PIC Guide DS3 PIC Q D Q a Q CC 0 f _ a A _J L J gt a JQ Software release m JUNOS 8 0R2 and later Type 1 NOTE This PIC is not supported in JUNOS Release 8 1R1
11. 08 A 48 V 3 7 W m Supports clear channel T1 per port 1 544 Mbps per channel m Supports attenuation up to 12 dBm Hardware features Per port loop timing Onboard DSU functionality for T1 connectivity Software features m ESF and SF framing m B8ZS and AMI coding m ESF CSU counters WRT impairments and CRC checking m Local DS1 line loopback remote line loopback m Configurable clock source internal or loop m Encapsulations E High Level Data Link Control HDLC m Frame Relay m Circuit cross connect CCC m Point to Point Protocol PPP Cables and connectors m 100 ohm RJ 48 connector LEDs One tricolor per port m Off Not enabled m Green Online with no alarms or failures m Amber Online with alarms for remote failures m Red Active with a local alarm router has detected a failure 112 gm T1PIC Alarms errors and events Alarm indication signal AIS Bipolar violations Excessive zeros Far end block errors FEBE E bit errors Loss of frame LOF Loss of signal LOS Yellow alarm bit X bit disagreements T1 PIC T1 PIC mw 113 M120 Internet Router PIC Guide Tunnel Services PIC Status QO OFFLINE 8 4 1800 Software release m JUNOS 8 0R2 and later Type 1 Type 2 and Type 3 NOTE This PIC is not supported in JUNOS Release 8 1R1 Description m Power requirement 0 07 A 48 V 3 4 W Hardware features m Loopback function that encapsulates and
12. 0C48 STM16 Multi Rate PIC with SFP SONET SDH 0C48 STM16 Multi Rate PIC with SFP MULTLRA SONET SFE o ONLINE ORL Ne Ostitus ae Stea oc mean Software release m JUNOS 8 3 and later Type 2 Description m Rate selectable using one of the following rates m port OC3c m port OC12 port OC12c m port OC48 m 1 port OC48c m Power requirement 0 20 A 48 V 9 5 W Hardware features m Multiplexing and demultiplexing m Rate policing on input m Rate shaping on output m Packet buffering Layer 2 parsing Software features m Optical diagnostics and related alarms m Per port SONET SDH framing m Link aggregation m Alarm and event counting and detection m Dual router automatic protection switching APS m Multiprotocol Label Switching MPLS fast reroute m Encapsulations m High Level Data Link Control HDLC Frame Relay Circuit cross connect CCC Translational cross connect TCC Point to Point Protocol PPP SONET SDH 0C48 STM16 Multi Rate PIC with SFP m 103 M120 Internet Router PIC Guide Cables and connectors You can install any transceiver supported by the PIC For information about installing and removing transceivers see the PIC and Transceiver Installation Instructions m Duplex LC PC connector Rx and Tx m Optical interface support See Table 33 on page 105 Table 34 on page 106 and Table 35 on page 106 NOTE To extend the life of
13. 18 11 GFEC 1075 10715 8 to 20 600 to 1200 20 13 GFEC 1075 10715 8 to 20 700 to 1500 In Table 22 on page 77 one Juniper index number corresponds to the factory set frequency that corresponds to the XENPAK OTN model number For example Juniper index number 32 corresponds to the factory set frequency 193 2 THz which corresponds to model number XENPAK 1XGE 32A OTN The other Juniper index number corresponds to the alternate frequency For example Juniper index number 33 corresponds to the alternate frequency 193 3 THz Table 22 XENPAK OTN Factory Set Alternate Frequency Wavelength Reference Factory Set Factory Set Juniper Alternate Alternate Juniper Model Number A Wavelength Frequency Index Wavelength Frequency THz Index denotes two nm THz Number nm Number wavelengths corresponds corresponds to to alternate factory set frequency frequency 1551 72 193 2 32 550 92 93 3 33 XENPAK 1 XGE 32A OT 1550 12 193 4 34 549 32 93 5 35 XENPAK 1 XGE 34A OT 1548 51 193 6 36 547 72 93 7 37 XENPAK 1 XGE 36A OT 1546 92 193 8 38 546 12 93 9 39 XENPAK 1 XGE 38A OT 1545 32 194 0 40 544 53 94 1 41 XENPAK 1XGE 40A OT 1543 73 194 2 42 542 94 94 3 43 XENPAK 1 XGE 42A OT 10 Gigabit Ethernet PIC with XENPAK 77 M120 Internet Router PIC Guide 10 Gigabit Ethernet DWDM PIC 10G STaTUg 0 ONUng p I OFFUiNg Un 0 Ota NCH Po 40 WER RX op Ethe
14. 530 to V 35 cable and connects to a V 35 DTE 34 pin Winchester type male cable one per port X 21 requires an EIA 530 to X 21 cable and connects to a X 21 DTE DB 15 male cable LEDs Three bicolor per port m Data set ready DSR m Green DSR is detected or ignored m Red DSR expected but not present m Data carrier detect DCD m Green DCD is detected or ignored m Red DCD expected but not present m Resynchronization m Green Keepalives are being received m Red Data terminal ready DTR toggled from low to high resynchronization pulses are being sent Instrumentation Per port packet and byte counters counters Resynchronization counters a Number of resynchronizations initiated m Time of last resynchronization EIA530 PIC mgm 55 M120 Internet Router PIC Guide Fast Ethernet PICs x lt M 2 ao 2 0 Z orts r b o Zz at if LINK E m 1385 Di Ethernet 100BASE FX STAT 00a a 0 Left 4 Port Fast Ethernet PIC Right 8 Port Fast Ethernet PIC gy a thernet 10 100 BASE Tx 2 O 0 q 9 sms K 000 D 59 0080 000 Ethernet 10100 BASE qx g Pe D PORTS 2435 Left 12 Port Fast Ethernet PIC Right 48 Port Fast Ethernet PIC 56 Fast Ethernet PICs n O a A a a Fast Ethernet PICs
15. Alarms errors and events Alarm indication signal AIS L AIS P Bit error rate signal degrade BERR SD bit error rate signal fail BERR SF Bit interleaved parity errors B1 B2 B3 CV S CV L CV P Errored seconds ES S ES L ES P far end bit errors REI L REI P CV LFE CV PFE far end errored seconds ES LFE ES PFE far end severely errored seconds SES LFE SES PFE far end unavailable seconds UAS LFE UAS PFE Loss of frame LOF loss of pointer LOP P loss of signal LOS Payload mismatch PLM P payload unequipped UNEQ P Remote defect indication RDI L RDI P Severely errored framing SEF severely errored framing seconds SEFS S severely errored seconds SES S SES L SES P unavailable seconds UAS L UAS P Instrumentation E counters Layer 2 per queue and per channel packet and byte counters 44 Em Channelized STM1 IQ PIC Channelized T1 IQ PIC OT ROSALYN d j h D a JNA R a A ie Lf Lp i J th Ly Hy i D Y A g002310 Channelized T1 IQ PIC Software release NOTE This PIC is not supported in JUNOS Release 8 1R1 JUNOS 8 0R2 and later Type 1 Description Ten T1 ports Power requirement 0 15 A 48 V 7 2 W Intelligent queuing IQ PICs support fine grained queuing per logical interface Channelization T1 FT1 NXDSO Channel
16. Errored seconds ES S ES L ES P far end bit errors REI L REI P CV LFE CV PFE far end Block error FEBE far end errored seconds ES LFE ES PFE far end severely errored seconds SES LFE SES PFE far end unavailable seconds UAS LFE UAS PFE Frame error dle code idle received Loss of frame LOF loss of pointer LOP P loss of signal LOS Out of frame OOF Payload mismatch PLM P payload unequipped UNEQ P Parity bit P bit disagreements Path parity error Remote defect indication RDI L RDI P Severely errored framing SEF severely errored framing seconds SEFS S Sseverely errored seconds SES S SES L SES P unavailable seconds UAS L UAS P Yellow alarm bit X bit disagreements Table 12 Optical Interface Support for Channelized OC3 IQ PICs PIC Type Intermediate Reach IR Optical interface Standard Maximum distance Transmit wavelength 38 mm Channelized OC3 IQ PIC Single mode Telcordia GR 253 9 3 miles 15 km 1274 through 1356 nm Channelized OC3 IQ PIC Table 12 Optical Interface Support for Channelized OC3 IQ PICs continued PIC Type Intermediate Reach IR Average launch power 15 through 8 dBm Receiver saturation 8 dBm Receiver sensitivity 28 dBm Channelized OC3 IQ PIC m 39 M120 Internet Router PIC Guide Channelized OC12 IQ PIC S Channeliz ed Qem Preemzance vo O C gi na e g 9003043 Software re
17. Gigabit Ethernet IQ2 PICs with SFP L__ Ethernet 1000BASE X Ez SFP z ee E ONLINE PORT OFFLINE Oo j Bo O a j di il y i ch MH unun unn i he aaa 4 39 Boo j Je Ji PH iD J oo PBgBe H a d J a fa a a J i i j j i j i W Mi y H W J i y j H A J J s H h i j j a J E veh df 4 9 W o0 g002360 Ql Left 4 port Gigabit Ethernet IQ2 PIC Type 1 Right 8 port Gigabit Ethernet IQ2 PIC Type 2 66 Gigabit Ethernet 1Q2 PICs with SFP Gigabit Ethernet IQ2 PICs with SFP Center 8 port Gigabit Ethernet IQ2 PIC Type 3 Software release 4 port JUNOS 8 0R2 and later Type 1 8 port JUNOS 8 0R2 and later Type 2 8 port JUNOS 8 5 and later Type 3 NOTE These PICs are not supported in JUNOS Release 8 1R1 Description Four or eight Gigabit Ethernet ports Power requirement m 4port 0 65 A 48 V 51W m 8 port Type 2 0 89 A 48 V 42 5W m 8 port Type 3 1 25 A 48 V 60 W Hardware features High performance throughput on each port m 4 port with SFP speeds up to 1 Gbps m 8 port with SFP speeds up to 4 Gbps Full duplex mode Large maxi
18. IQ2 PICs Parameter 10 GBase S 10 GBase L 10 GBase E 10 GBase Z Transceiver model XFP 10G S XFP 10G L OC192 SR1 XFP 10G E OC192 IR2 XFP 10G Z OC192 LR2 number Optical interface Multimode Single mode Single mode Single mode Transceiver type XFP XFP XFP XFP Standard IEEE 802 3ae 2002 IEEE 802 3ae 2002 IEEE 802 3ae 2002 Multivendor agreement Maximum distance Transmitter wavelength Average launch power Average receive power Receiver saturation Receiver sensitivity 50 125 MMF cable 2000 MHz km 984 feet 300 m 50 125 MMF cable 500 MHz km 269 feet 82 m 50 125 MMF cable 400 MHz km 217 feet 66 m 62 5 125 MMF cable 200 MHz km 108 feet 33 m 62 5 125 MMF cable 160 MHz km 85 feet 26 m 840 nm through 860 nm 4 5 through 1 dBm 9 9 through 1 0 dBm 1 0 dBm 9 9 dBm 9 125 SMF cable 6 2 miles 10 km 1260 through 1355 nm 8 2 through 0 5 dBm 14 4 through 0 5 dBm 0 5 dBm 14 4 dBm 9 125 SMF cable 24 8 miles 40 km Distances greater than 30 km are considered to be engineered links 1530 through 1565 nm 4 7 through 4 dBm 15 8 through 1 0 dBm 1 0 dBm 15 8 dBm 9 125 SMF cable 49 6 miles 80 km 1530 through 1565 nm 0 through 4 dBm 24 0 through 7 0 dBm 7 dBm 24 dBm 72 Em 10 Gigabit Ethernet IQ2 PIC with XFP 10 Gigabit Ethernet PIC with XENPAK 10 Gigabit Ethernet PIC with XENPAK SPASE EN pay O sm
19. P Payload unequipped unequipped STS at path level UNEQ P Remote defect indication line RDI L Remote defect indication path RDI P alarms Multiplex section alarm indication signal MS AIS Administrative unit alarm indication signal AU AIS Bit error rate signal degrade BERR SD Bit error rate signal fail BERR SF Bit interleaved parity BIP error B1 Bit interleaved parity BIP error B2 Bit interleaved parity BIP error B3 Loss of frame LOF Loss of pointer HP LOP Loss of signal LOS Multiplex section remote error indication MS RE I Higher path label mismatch HP PLM Higher path unequipped HP UNEQ Multiplex section remote defect indication MS RDI Higher path remote defect indication HP RDI Errored seconds ES S ES L ES P far end errored seconds ES LFE ES PFE far end severely errored seconds SES LFE SES PFE far end unavailable seconds UAS LFE UAS Seve PFE ely errored framing SEF severely errored framing seconds SEFS S severely errored seconds SES S SES L SES P unavailable seconds UAS L UAS P Table 26 Optical Interface Support for SONET SDH OC3 STM1 Multi Rate PICs Configured at an OC3 STM1 Rate Parameter Multimode Intermediate Reach IR 1 Long Reach LR 1 Transceiver model SFP OC3 SR SFP OC3 IR SFP OC3 LR number SONET SDH OC3 STM1 Multi Rate PICs with SFP mg 89 M120 Internet Router PIC Guide Table 26 Optical Interface Suppo
20. Page 10 Gigabit Ethernet DWDM 1 8 0R2 78 Gigabit Ethernet with SFP 1 8 0R2 60 Gigabit Ethernet with SFP 2 8 0R2 60 Gigabit Ethernet with SFP 4 8 0R2 60 Gigabit Ethernet with SFP 10 8 0R2 60 Ethernet IQ Gigabit Ethernet IQ with SFP 1 8 0R2 63 Gigabit Ethernet IQ with SFP 2 8 0R2 63 Ethernet IQ2 Gigabit Ethernet IQ2 with SFP 4 8 0R2 66 Gigabit Ethernet IQ2 with SFP 8 8 0R2 66 Gigabit Ethernet IQ2 with SFP 8 8 5 66 10 Gigabit Ethernet IQ2 with XFP 1 8 2 70 Services Adaptive Services II 0 8 0R2 12 Adaptive Services II Layer 2 Services 0 8 0R2 17 Adaptive Services II FIPS 0 8 0R2 15 MultiServices 100 0 8 2R2 80 MultiServices 400 0 8 2 80 MultiServices 500 0 8 3 80 Tunnel Services 0 8 0R2 114 Tunnel Services 0 8 0R2 114 Tunnel Services 0 8 0R2 114 SONET SDH SONET SDH OC3c STM1 4 8 0R2 83 SONET SDH OC3 STM1 Multi Rate 4 8 4 87 with SFP SONET SDH OC3 STM1 Multi Rate 4 8 3 87 with SFP Table 1 PICs Supported by the M120 Internet Router continued First JUNOS PIC Family and Type Ports Support Page SONET SDH OC12c STM4 1 8 0R2 91 SONET SDH OC12 STM4 1 8 4 94 Multi Rate with SFP SONET SDH OC12 STM4 4 8 3 94 Multi Rate with SFP SONET SDH OC48c STM16 with SFP 4 8 0R2 99 SONET SDH OC48 STM16 1 8 3 103 Multi Rate with SFP SONET SDH OC192c STM64 PIC 1 8 3 108 with XFP M120 Internet Router PIC Guide FPCs and cFPCs Supported M120 routers support the FPCs listed in Table 2 on page 6 Table 2 FPCs Supported by the M12
21. SMF cable 49 6 miles 80 km 1530 through 1565 nm 0 through 4 dBm 10 Gigabit Ethernet PIC with XENPAK Table 19 Optical Interface Support for 10 Gigabit Ethernet PICs with XENPAK continued Parameter Short Wavelength Serial LOGBase SR LAN Rate Long Wavelength Serial LOGBase LR LAN Rate Extra Long Wavelength Serial LOGBase ER LAN Rate Extra Long Wavelength Serial 1O0GBase ZR LAN Rate Average receive power Receiver saturation Receiver sensitivity 9 9 through 1 0 dBm 1 0 dBm 9 9 dBm 14 4 through 0 5 dBm 0 5 dBm 14 4 dBm 15 8 through 1 0 dBm 1 0 dBm 15 8 dBm 24 0 through 7 0 dBm 7 dBm 24 dBm These tables describe the 10 Gigabit Ethernet XENPAK OTN transceivers Table 20 on page 75 Table 21 on page 76 and Table 22 on page 77 Table 20 Optical Interface Support for 10 Gigabit Ethernet PICs with XENPAK OTNs Model numbers XENPAK XENPAK XENPAK XENPAK XENPAK XENPAK XGE 32A OTN XGE 34A OTN XGE 36A OTN XGE 38A OTN XGE 40A OTN XGE 42A OTN Features 10 Gigabi digital wrapper with over clocked G 709 framing m Generic Reed Solomon forward error correction GFEC to transport 1 OGBASE R 1 0 Gigabit Ethernet LAN m Reduced cost of deploying and maintaining the network due to m Fewer optical electrical optical OEO conversions m Fewer optical amplifiers and regenerators Two tunable wavelengths channels
22. SONET SDH 0C12 STM4 Multi Rate PIC Right 4 port SONET SDH 0C12 STM4 Multi Rate PIC Software release 1 port JUNOS 8 4 and later Type 1 m 4 port JUNOS 8 3 and later Type 2 Description m___1 port Rate selectable using one of the following rates a port OC3 a port OC12 a port OC12c m 4 port Rate selectable using one of the following rates a port OC12 a port OC48 a port OC48c m 4port OC3c m 4port OC12c m Power requirement I port 0 20 A 48 V 9 5 W m 4port 0 40 A 48 V 19 W Hardware features Multiplexing and demultiplexing Rate policing on input Rate shaping on output Packet buffering Layer 2 parsing 94 mm SONET SDH 0012 STM4 Multi Rate PICs with SFP Software features SONET SDH 0C12 STM4 Multi Rate PICs with SFP Optical diagnostics and related alarms Per port SONET SDH framing Link aggregation Alarm and event counting and detection Dual router automatic protection switching APS Multiprotocol Label Switching MPLS fast reroute Encapsulations E High Level Data Link Control HDLC Frame Relay Circuit cross connect CCC Translational cross connect TCC Point to Point Protocol PPP Cables and connectors You can install any transceiver supported by the PIC For information about installing and removing transceivers see the PIC and Transceiver Installation Instructions m Duplex LC PC connector Rx and Tx m Optical interface support See T
23. SONET SDH frames ASIC based packet segmentation and reassembly SAR management and output port queuing 64 MB SDRAM memory for ATM SAR Packet buffering Layer 2 parsing 24 a ATM2 0C3 STM1 IQ PIC ATM2 0C3 STM1 IQ PIC Software features Circuit cross connect CCC for leveraging ATM access networks User configurable virtual circuit VC and virtual path VP support Support for idle cell or unassigned cell transmission OAM fault management processes alarm indication signal AIS remote defect indicator RDI cells and loop cells Point to point and point to multipoint mode Layer 2 counters per VC and per VP Local and remote loopback ATM Inverse Address Resolution Protocol ARP which enables routers to automatically learn the IP address of the router on the far end of an ATM permanent virtual circuit PVC m Simple Network Management Protocol SNMP L Management Information Base MIB 2 RFC 1213 m ATM MIB RFC 1695 m SONET MIB m Unspecified bit rate UBR non real time variable bit rate VBR and constant bit rate CBR traffic shaping Per VC or per VP traffic shaping Support for F4 OAM cells m Support for 16 bit VCI range Cables and connectors Duplex SC PC connector RX and TX Optical interface support See Table 9 on page 25 LEDs One tricolor per port Off Not enabled Green Online with no alarms or failures Amber Online with alarms for remote failures Red Active with a loca
24. STM4 Multi Rate Type 1 PICs Added EIA 530 PIC 30 March 2007 530 020469 01 Revision 1 Added MultiServices 100 and 500 PICs Added SONET SDH OC192c STM64 PIC with XFP SONET SDH OC3 Multi Rate PIC with SFP SONET SDH OC12 Multi Rate PIC with SFP and SONET SDH OC48 Multi Rate PIC with SFP Added connectors to the supported cFPCs table 2 January 2007 530 017885 01 Revision 1 Added MultiServices 400 PIC for JUNOS Release 8 2 Removed product reclamation and recycling 26 October 2006 530 0161 12 01 Revision 2 Updated FPC throughput numbers 05 October 2006 530 0161 12 01 Revision 1 he information in this document is current as of the date listed in the revision history YEAR 2000 NOTICE uniper Networks hardware and software products are Year 2000 compliant The JUNOS software has no known time related limitations through the year 2038 However the NTP application is known to have some difficulty in the year 2036
25. de encapsulates packets OC12 STM4 tunneling bandwidth on FPC1 OC48 STM16 tunneling bandwidth on FPC2 OC192 STM64 tunneling bandwidth on FPC3 Software features For a list of the software features available for services PICs see the JUNOS Services Interfaces Configuration Guide m IP IP unicast tunneling m GRE unicast tunneling m PIM sparse mode unicast tunneling LEDs One tricolor m Off Not enabled E Green Online with no alarms or failures m Amber Online with alarms for remote failures m Red Active with a local alarm router has detected a failure 114 gm Tunnel Services PIC Appendix A High Availability Features High availability features include Routing Engine redundancy graceful Routing Engine switchover GRES nonstop bridging nonstop active routing graceful restart for routing protocols Virtual Router Redundancy Protocol VRRP and unified in service software upgrade ISSU Some high availability features are not supported by all platforms and all PICs For information about the first supported JUNOS release for these features by PIC and platform see the JUNOS High Availability Configuration Guide m 115 Copyright 2008 Juniper Networks Inc All rights reserved Juniper Networks the Juniper Networks logo NetScreen and ScreenOS are registered trademarks of Juniper Networks Inc in the United States and other countries JUNOS and JUNOSe are trademarks of Juniper Networks Inc All other trade
26. interface Channelization DS3 DS1 DSO Optical interface support see Table 12 on page 38 Hardware features m Subrate and scrambling Digital Link Quick Eagle Kentrox Larscom Adtran Verilink Packet buffering Layer 2 parsing M13 C bit parity encoding DS3 far end alarm and control FEAC channel support Local and remote loopback testing Channelized OC3 IQ PIC m 37 M120 Internet Router PIC Guide Software features C Quality of Service QoS per channel weighted round Robin WRR random early drop RED weighted random early drop WRED Simple Network Management Protocol SNMP OC3 MIB DS3 MIB T1 MIB Dynamic arbitrary channel configuration Full Bit Error Rate Testing BERT Encapsulations E High Level Data Link Control HDLC Frame Relay Circuit cross connect CCC Translational cross connect TCC Point to Point Protocol PPP Cables and connectors E Duplex SC PC connector Rx and Tx single mode fiber intermediate reach fiber LEDs One tricolor per port Off Not enabled Green Online with no alarms or failures Amber Online with alarms for remote failures Red Active with a local alarm router has detected a failure Alarms errors and L events E E E E E E E E E E E E Alarm indication signal AIS L AIS P Bit error rate signal degrade BERR SD bit error rate signal fail BERR SF Bit interleaved parity errors B1 B2 B3 CV S CV L CV P
27. support Support for idle cell or unassigned cell transmission OAM fault management processes alarm indication signal AIS remote defect indication RDI and loop cells Point to point and point to multipoint mode Layer 2 counters per VC and per VP Local and remote loopback ATM Inverse ARP which enables routers to automatically learn the IP address of the router on the far end of an ATM PVC m Simple Network Management Protocol SNMP L Management Information Base MIB 2 RFC 1213 m ATM MIB RFC 1695 m SONET MIB m Unspecified bit rate UBR non real time variable bit rate VBR and constant bit rate CBR traffic shaping Per VC or per VP traffic shaping Support for F4 OAM cells Support for 16 bit VCI range Cables and connectors m Duplex SC PC connector Rx and Tx Optical interface support See Table 10 on page 28 LEDs One tricolor per port m Off Not enabled E Green Online with no alarms or failures m Amber Online with alarms for remote failures m Red Active with a local alarm router has detected a failure Alarms errors and events Alarm indication signal AIS L AIS P Bit error rate signal degrade BERR SD bit error rate signal fail BERR SF Bit interleaved parity errors B1 B2 B3 Errored seconds ES S ES L ES P far end bit errors REI L REI P CV LFE CV PFE far end errored seconds ES LFE ES PFE far end severely errored seconds SES LFE SES PFE far end unavailable seconds UA
28. supported per XENPAK OTN module Link fault switchover PC 1XGE XENPAK PIC feature support Transceiver type mw XE PAK module Standards ITU T G 709 Interfaces for the Optical Transport Network OTN ITU T G 873 1 Optical Transport Network OTN Linear Protection RFC 3591 Definitions of Managed Objects for the Optical Interface Type Line interface A G 709 Line rate 11 09 Gbps Line rate deviation 20 ppm G 709 LAN PHY with stuffing Dispersion window 600 to 1200 ps nm or 700 to 1500 ps nm maximum FEC type Generic Reed Solomon RS 255 239 code computed as specified in Annex 10 Gigabit Ethernet PIC with XENPAK m 75 M120 Internet Router PIC Guide Table 20 Optical Interface Support for 10 Gigabit Ethernet PICs with XENPAK OTNs continued Optical transmitter Transmitter type Electro absorption Modulated Laser EML Modulation format Non retum to zero NRZ Channel plan wavelength range 1551 72 through 1542 94 nm Channel plan frequency range 193 2 through 194 3 THz Channel spacing 100 GHz Channel tunability 2 channels Output power on 0 to 3 dBm Output power off lt 40 dBm Output power stability 0 6 dB Wavelength accuracy 100 pm Tuning time Warm tune 10 seconds Cold start 40 seconds Extinction ratio 9 dB Side mode suppression ratio 2 30 dB Jitter generation compliance GR 253 G 8251 Optical receiver Receiver type Avalanche p
29. 0 Internet Router PIC Guide LEDs One tricolor per port Gree Amb Off Not enabled n Online with no alarms or failures er Online with alarms for remote failures Red Active with a local alarm router has detected a failure Alarms errors and m SONET alarms events SDH Alarm indication signal line AIS L Alarm indication signal path AIS P Bit error rate signal degrade BERR SD Bit error rate signal fail BERR SF Bit interleaved parity BIP error B1 Bit interleaved parity BIP error B2 Bit interleaved parity BIP error B3 Loss of frame LOF Loss of pointer LOP P Loss of signal LOS Far end bit error remote error indication line REI L CV LFE Far end bit error remote error indication path REI P CV PFE Payload mismatch path label mismatch PLM P Payload unequipped unequipped STS at path level UNEQ P Remote defect indication line RDI L Remote defect indication path RDI P alarms Multiplex section alarm indication signal MS AIS Administrative unit alarm indication signal AU AIS Bit error rate signal degrade BERR SD Bit error rate signal fail BERR SF Bit interleaved parity BIP error B1 Bit interleaved parity BIP error B2 Bit interleaved parity BIP error B3 Loss of frame LOF Loss of pointer HP LOP Loss of signal LOS Multiplex section remote error indication MS REI igher path label mismatch HP PLM igher path unequip
30. 0 Router FPC Type FPC Name FPC Model Number Maximum Number Maximum Throughput First JUNOS of PICs Supported per FPC Release per FPC 1 FPC1 M120 FPC1 4 4 Gbps 8 0R2 2 FPC2 M120 FPC2 4 10 Gbps 8 0R2 3 FPC3 M120 FPC3 1 10 Gbps 8 0R2 A cFPC is a combination of a PIC and an FPC It contains the interface circuitry and the FPC as a single assembly Both cFPCs provide receptacles for XFP optical transceivers The M120 chassis provides two slots for cFPCs and supports any combination of cFPC types M120 routers support the cFPCs listed in Table 3 on page 6 Table 3 cFPCs Supported by the M120 Router cFPC Name cFPC Model Maximum First JUNOS Connector Number Throughput per Release cFPC 10 Gigabit Ethernet M120 cFPC 1XGE XFP 10 Gbps 8 0R2 Duplex LC PC Rx and Tx SONET SDH OC192 STM64 M120 cFPC 10C192 XFP 10 Gbps 8 0R2 Duplex LC PC Rx and Tx The 10 Gigabit Ethernet cFPC supports the XFPs listed in Table 4 on page 6 Table 4 Optical Interface Support for 10 Gigabit Ethernet cFPC Parameter 10 GBASE S 10 GBASE L 10 GBASE E 10 GBASE Z Transceiver model XFP 10G S XFP 10G L OC192 SR1 _XFP 10G E OC192 IR2 XFP 10G Z OC192 LR2 number Optical interface Multimode Single mode Single mode Single mode Transceiver type XFP XFP XFP XFP Standard IEEE 802 3ae 2002 IEEE 802 3ae 2002 IEEE 802 3ae 2002 Multivendor agreement 6 wm FPCsandcFPCs Supported FPCs and cFPCs Supported Table 4 Optical Interface Support for
31. 10 Gigabit Ethernet cFPC continued Parameter 10 GBASE S 10 GBASE L 10 GBASE E 10 GBASE Z Maximum distance Transmitter wavelength Average launch power Average receive power Receiver saturation Receiver sensitivity 50 125 MMF cable 2000 Mhz kKm 984 feet 300 m 50 125 MMF cable 500 Mhz Km 269 feet 82 m 50 125 MMF cable 400 Mhz Km 217 feet 66 m 62 5 125 MMF cable 200 Mhz Km 108 feet 33 m 62 5 125 MMF cable 160 Mhz Km 85 feet 26 m 840 through 860 nm 4 5 through 1 dBm 9 9 through 1 0 dBm 1 0 dBm 9 9 dBm 9 125 SMF cable 6 2 miles 10 km 1260 through 1355 nm 4 through 0 5 dBm 14 4 through 0 5 dBm 0 5 dBm 14 4 dBm 9 125 SMF cable 24 8 miles 40 km Distances greater than 30 km are considered to be engineered links 1530 through 1565 nm 4 7 through 4 dBm 15 8 through 1 0 dBm 1 0 dBm 15 8 dBm 9 125 SMF cable 49 6 miles 80 km 1530 through 1565 nm O through 4 dBm 24 0 through 7 0 dBm 7 dBm 24 dBm The SONET SDH OC192 STM64 cFPC supports the XFPs listed in Table 5 on page 7 Table 5 Optical Interface Support for SONET SDH 0C192 STM64 cFPC Parameter Short reach SR 1 Intermediate reach IR 2 Long Reach LR 2 Transceiver model number Optical interface Transceiver type Standard XFP 10G L OC192 SR1 Single mode XFP Telcordia GR 253 OC192 SRI XFP 10G E OC1 92 IR2 S
32. 11 M120 Internet Router PIC Guide Adaptive Services Il PIC STATUg T app Q Pe Le OL TM TIT gt i 5 h CY g002114 Software release E JUNOS 8 0R2 and later Type 1 NOTE This PIC is not supported in JUNOS Release 8 1R1 Description 7 Supports tunnel services This feature is included with the PIC and does not require an individual license Individual licenses must be purchased for additional services Power requirement 0 4 A 48 V 19 W Hardware features Support for up to 2000 service sets Active monitoring on up to 1 million flows Support for MTUs up to 9192 bytes for Gigabit Ethernet and SONET interfaces Software features Depending on your JUNOS release and individual licenses software features for this PIC can include the features listed in Table 7 on page 13 For more information about the software features available for services PICs see the JUNOS Services Interfaces Configuration Guide LEDs Status LED one tricolor Off PIC is offline and it is safe to remove it from the chassis Green PIC is operating normally Amber PIC is initializing Red PIC has an error or failure and no further harm can be done by removing it from the chassis Application LED one bicolor Off Service is not running Green Service is running under acceptable load Amber Service is overloaded 12 gm Adaptive Services II PIC Adaptive Services II PI
33. 1380 nm 20 through 14 dBm 14 dBm 30 dBm 26 mm ATM20C3 STM1 IQ PIC ATM2 0C12 STM4 IQ PICs ATM2 0C12 STM4 IQ PICs Left 1 port ATM2 0C12 STM4 IQ PIC Right 2 port ATM2 0C12 STM4 IQ PIC Software release 1 port JUNOS 8 0R2 and later Type 1 2 port JUNOS 8 0R2 and later Type 2 NOTE These PICs are not supported in JUNOS Release 8 1R1 Description One or two OC12 ports Power requirement m I port 0 41 A 48 V 20 W m 2 port 0 52 A 48 V 25 W Intelligent queuing IQ PICs support fine grained queuing per logical interface Conforms to ANSI T1 105 1991 and T1E1 2 93 020R1 Complies with ATM and SONET SDH standards Alarm and event counting and detection Compatible with well known ATM switches ATM switch ID which displays the switch IP address and local interface name of the adjacent Fore ATM switches Hardware features ATM2 IQ 1 port OC12 PICs have one 3010 SAR for segmentation and reassembly into 53 byte ATM cells ATM2 IQ 2 port OC12 PICs have dual 3010 SAR High performance parsing of SONET SDH frames ASIC based packet segmentation and reassembly SAR management and output port queuing 64 MB SDRAM memory for ATM SAR Packet buffering Layer 2 parsing ATM2 0C12 STM4 IQ PICS 27 M120 Internet Router PIC Guide Software features Circuit cross connect for leveraging ATM access networks User configurable virtual circuit VC and virtual path VP
34. 2 L Multilink Frame Relay MLFR L Multilink Point to Point Protocol MLPP 14 Adaptive Services II PIC Adaptive Services II FIPS PIC Adaptive Services Il FIPS PIC STATUg Sop Q Pe Le OL h CY g002302 Software release m JUNOS 8 0R2 and later Type 1 NOTE This PIC is not supported in JUNOS Release 8 1R1 Description m JUNOS FIPS requires an Adaptive Services II FIPS PIC for external IPSec connections See the Secure Configuration Guide for Common Criteria and JUNOS FIPS for more information m Supports tunnel services This feature is included with the PIC and does not require an individual license m Individual licenses must be purchased for additional services such as Network Address Translation NAT stateful firewall intrusion detection services IDS IPSec J Flow accounting and voice services For information about which services are supported by PIC and platform type see the JUNOS Services Interfaces Configuration Guide m Power requirement 0 4 A 48 V 19 W Hardware features Support for up to 2000 service sets Active monitoring on up to 1 million flows Support for MTUs up to 9192 bytes for Gigabit Ethernet and SONET interfaces Adaptive Services II FIPS PIC m 15 M120 Internet Router PIC Guide Software features For a list of the software features available for services PICs see the JUNOS Services Interfaces Configuration Gui
35. 3 m ATM MIB RFC 1695 m SONET MIB m Unspecified bit rate UBR non real time variable bit rate VBR and constant bit rate CBR traffic shaping Per VC or per VP traffic shaping Support for F4 OAM cells Support for 16 bit VCI range Cables and connectors m Duplex LC PC connector RX and TX LEDs One tricolor per port m Off Not enabled m Green Online with no alarms or failures m Amber Online with alarms for remote failures m Red Active with a local alarm router has detected a failure Alarms errors and r Alarm indication signal AIS L AIS P events m Bit error rate signal degrade BERR SD bit error rate signal fail BERR SF m Bit interleaved parity errors B1 B2 B3 Errored seconds ES S ES L ES P far end bit errors REI L REI P CV LFE CV PFE far end errored seconds ES LFE ES PFE far end severely errored seconds SES LFE SES PFE far end unavailable seconds UAS LFE UAS PFE m Loss of cell delineation LOC loss of frame LOF loss of pointer LOP P loss of signal LOS Payload mismatch PLM P payload unequipped UNEQ P Remote defect indication RDI L RDI P Severely errored framing SEF severely errored framing seconds SEFS S severely errored seconds SES S SES L SES P unavailable seconds UAS L UAS P Table 11 Optical Interface Support for ATM2 IQ OC48 PICs PIC Type Single Mode Intermediate Reach Optical interface Transceiver type Single mode SFP
36. 3 dBm 19 through 3 dBm 3 dBm 19 dBm 9 125 SMF cable 43 5 miles 70 km 1480 through 1580 nm 3 through 3 dBm 20 through 3 dBm 3 dBm 20 dBm Gigabit Ethernet IQ2 PICs with SFP m 69 M120 Internet Router PIC Guide 10 Gigabit Ethernet I1Q2 PIC with XFP thernet 10 GBASE XFP SEX a j P ie i j j ONLINE OFFLINE P id H j j y i 4 j i te a f j ih if j j d i i ch of a Ok eS A i J aid iy ai ii ji j H i 5 5 a i d jan i i S5 Software release m JUNOS 8 2 and later Type 3 One 10 Gigabit Ethernet port Description Power requirements 1 2 A 48 V 56 W High performance throughput WAN PHY mode at 9 953 Gbps LAN PHY mode at 10 3125 Gbps Hardware features Full duplex mode Large maximum transmission units MTUs of up to 9192 bytes 70 mf 10 Gigabit Ethernet 1Q2 PIC with XFP Software features 10 Gigabit Ethernet IQ2 PIC with XFP m Quality of service QoS per channel weighted round robin WRR random early detection RED weighted random early detection WRED m Configurable WAN PHY mode options m loopback mpls m path trace m trigger Virtual Router Redundancy Protocol VRRP support Hierarchical shaping Fine grained queueing and shaping per logical interface at both ingress and eg
37. 5 nm 3 through 2 dBm 8 dBm 28 dBm 90 Em SONET SDH OC3 STM1 Multi Rate PICs with SFP SONET SDH 0C12c STMA4 PIC SONET SDH 0C12c STM4 PIC D 1 oa ag po 5a0 PO pa ES ay Oe g h a ff g g a 2 oo Status LED Software release m JUNOS 8 0R2 and later NOTE This PIC is not supported in JUNOS Release 8 1R1 Description m One OC12 port Power requirement 0 23 A 48 V 10 8 W Hardware features m Multiplexing and demultiplexing m Rate policing on input m Rate shaping on output m Packet buffering Layer 2 parsing Software features m SONET SDH framing m Link aggregation m Alarm and event counting and detection m Dual router automatic protection switching APS m Multiprotocol Label Switching MPLS fast reroute m Encapsulations E High Level Data Link Control HDLC Frame Relay Circuit cross connect CCC Translational cross connect TCC Point to Point Protocol PPP Cables and connectors Duplex SC PC connector Rx and Tx m Optical interface support See Table 28 on page 93 NOTE To extend the life of the laser when a PIC is not being actively used with any valid links take the PIC offline until you are ready to establish a link to another device For information about taking a PIC offline see the request chassis pic offline command in the JUNOS System Basics and Services Command Reference SONET SDH OC12c STM4 PIC m 91 M12
38. 6 IQ SFP 1 PB 1OC48 ATM2 SFP 8 0R2 Channelized IQ PICs ChDS3 IQ 4 PB 4CHDS3 QPP 8 0R2 ChE1 IQ 10 PB 1OCHE1 RJ48 QPP 8 0R2 ChOC3 IQ 1 PB 1 CHOC3 SMIR QPP 8 0R2 ChOC12 IQ 1 PB 1 CHOC12SMIR QPP 8 0R2 ChSTM1 IQ 1 PB 1 CHSTM1 SMIR QPP 8 0R2 ChT1 IQ 10 PB 1 OCHT 1 RJ48 QPP 8 0R2 T1 DS3 E1 E3 PICs DS3 4 PB 4DS3 8 0R2 El PB 4E1 COAX 4 8 0R2 PB 4E1 RJ48 Tl 4 PB 4T1 RJ48 8 0R2 E3 IQ PIC E3 IQ 4 PB 4E3 QPP 8 0R2 PIC FPC Compatibility E 9 M120 Internet Router PIC Guide Table 6 M120 PIC FPC Compatibility continued PIC Type Number of Ports PIC Model Number FPC1 FPC2 FPC3 EIA 530 PIC EIA 530 2 PB 2EIA530 8 0R2 Ethernet PICs Fast Ethernet 4 PB 4FE TX 8 0R2 Fast Ethernet 8 PB 8FE FX 8 0R2 Fast Ethernet 12 PB 12FE TX 8 0R2 Fast Ethernet 48 PB 48FE TX 8 0R2 Gigabit Ethernet SFP 1 PB 1 GE SFP 8 0R2 Gigabit Ethernet SFP 2 PB 2GE SFP 8 0R2 Gigabit Ethernet SFP 4 PB 4GE SFP 8 0R2 Gigabit Ethernet SFP 10 PC 1 OGE SFP 8 0R2 10 Gigabit Ethernet PICs 10 Gigabit Ethernet XENPAK 1 PC 1 XGE XENPAK 8 0R2 10 Gigabit Ethernet DWDM 1 PC 1XGE DWDM CBAND 8 0R2 Ethernet IQ PICs Gigabit Ethernet IQ SFP 1 PB 1GE SFP QPP 8 0R2 Gigabit Ethernet IQ SFP 2 PB 2GE SFP QPP 8 0R2 10 Gigabit Ethernet IQ2 PICs 10 Gigabit Ethernet IQ2 PIC XFP 1 PC 1 XGE TYPE3 XFP IQ2
39. 8 ports Power requirement 0 86 A 48 V 41 4 W Hardware features m Multiplexing and demultiplexing on the 1 port PIC m Rate policing on input m Rate shaping on output m Packet buffering Layer 2 parsing Software features m Optical diagnostics and related alarms m SONET SDH framing m Link aggregation m Alarm and event counting and detection m Dual router automatic protection switching APS m Multiprotocol Label Switching MPLS fast reroute m Encapsulations E High Level Data Link Control HDLC Frame Relay Circuit cross connect CCC Translational cross connect TCC Point to Point Protocol PPP SONET SDH OC48c STM16 PIC with SFP mf 99 M120 Internet Router PIC Guide Cables and connectors You can install any transceiver supported by the PIC For information about installing and removing transceivers see the PIC and Transceiver Installation Instructions m Duplex LC PC connector Rx and Tx m Optical interface support See Table 32 on page 101 NOTE To extend the life of the laser when a PIC is not being actively used with any valid links take the PIC offline until you are ready to establish a link to another device For information about taking a PIC offline see the request chassis pic offline command in the JUNOS System Basics and Services Command Reference LEDs One tricolor per port Off Not enabled Green Online with no alarms or failures Amber Online with alarms for remote fail
40. ANs VLANs support 802 3ae link aggregation support RMON EtherStats Cables and connectors E Duplex SC PC connector RX and TX LEDs Status LED one bicolor Off PIC is not enabled Green PIC is operating normally Red PIC has an error or failure Port LEDs one pair Link If green the port is online if there is no light the port is down RX If flashing green the port is receiving data if there is no light the port might be on but is not receiving data Table 23 Optical Interface Support for 10 Gigabit Ethernet DWDM PICs Parameter Extra Long Wavelength Serial DWDM LAN Rate Optical interface Transceiver type Standard Maximum distance Transmitter wavelength Average launch power Transmit extinction ratio Average receive power Receiver saturation Receiver sensitivity Single mode Dense wavelength division multiplexing DWDM ITU T G 694 1 9 125 SMF cable 49 6 miles 80 km 1528 77 through 1563 86 nm 100 GHz ITU grid 0 through 4 dBm 9 dBm 7 dBm through 24 dBm 7 dBm 24 dBm 10 Gigabit Ethernet DWDM PIC a 79 M120 Internet Router PIC Guide MultiServices PICs MultiSeryogg 400 Stan alae Sine Ap IS Dag Vo NU NEO ye Left MultiServices 100 PIC Right MultiServices 400 PIC MultiServices 500 O Starug PP D Pe Q ONLINE ig E
41. C Table 7 Adaptive Services PICs Software Features Supported by the M120 Router Software Feature Adaptive Services Il Adaptive Services PIC Il Layer 2 Services PIC GRE Key GRE dont fragment Stateful firewall with packet inspection detects 8 0R2 SYN attacks ICMP and UDP floods and ping of death attacks Network Address Translation NAT for IP 8 0R2 addresses Port Address Translation PAT for port numbers 8 0R2 IP Security IPSec encryption 8 0R2 7 Active flow monitoring exports cflowd version 8 0R2 E 5 and version 8 records Active flow monitoring exports flow monitoring 8 3 version 9 records based on RFC 3954 IP v4 templates only Passive flow monitoring a Passive flow collection z Flow tap 7 Dynamic flow capture Real time performance monitoring 8 3 Link services 8 0R2 8 0R2 Tunnel services 8 0R2 8 0R2 IP IP unicast tunneling GRE unicast tunneling Supports GRE fragmentation m Protocol Independent Multicast PIM sparse mode unicast tunneling Virtual tunnel interface for Layer 3 VPNs 8 0R2 Layer 2 Tunneling Protocol L2TP 8 0R2 8 0R2 Voice services 8 0R2 8 0R2 m Compressed Real Time Transport Protocol CRTP Adaptive Services II PIC m 13 M120 Internet Router PIC Guide Table 7 Adaptive Services PICs Software Features Supported by the M120 Router continued Encapsulations 8 0R
42. JUNOS Release 8 1R1 Description m Supports Layer 2 Service package only Tunnel services are included with the PIC Other services require an individual license m Power requirement 0 4 A 48 V 19 W Hardware features m Support for up to 2000 service sets Support for MTUs up to 9192 bytes for Gigabit Ethernet and SONET interfaces Software features Depending on your JUNOS release and individual licenses software features for this PIC can include the features listed in Table 8 on page 18 For more information about the software features available for services PICs see the JUNOS Services Interfaces Configuration Guide LEDs Status LED one tricolor m Off PIC is offline and it is safe to remove it from the chassis m Green PIC is operating normally m Amber PIC is initializing m Red PIC has an error or failure and no further harm can be done by removing it from the chassis Application LED one bicolor m Off Service is not running m Green Service is running under acceptable load m Amber Service is overloaded Adaptive Services II Layer 2 Services PIC m 17 M120 Internet Router PIC Guide Table 8 Adaptive Services PICs Software Features Software Feature Adaptive Services Il Adaptive Services PIC Il Layer 2 Services PIC GRE Key GRE dont fragment Stateful firewall with packet inspection detects 8 0R2 SYN attacks ICMP and UDP floods and ping of death attacks
43. M120 Internet Router PIC Guide Juniper Networks Inc 1194 North Mathilda Avenue Sunnyvale California 94089 USA 408 745 2000 www juniper net Part Number 530 024399 01 Revision 1 M120 Internet Router PIC Guide This guide provides an overview and description of the Physical Interface Cards PICs supported by the Juniper Networks M120 Internet router The PICs are described alphabetically Table 1 on page 3 lists the PICs supported by the M120 Internet router by PIC family PICs provide the physical connection to various network media types The PICs are mounted on Flexible PIC Concentrators FPCs which are inserted into a slot ina router A PIC typically occupies a single slot on an FPC PICs receive incoming packets from the network and transmit outgoing packets to the network During this process each PIC performs framing and high speed signaling for its media type Before transmitting outgoing data packets the PICs encapsulate the packets received from the FPCs Each PIC is equipped with a media specific ASIC that performs control functions tailored to the PIC s media type For complete information about installing PICs and transceivers see the PIC and Transceiver Installation Instructions located at http www juniper net techpubs Blank PICs resemble other PICs but do not provide any physical connection or activity When a slot is not occupied by a PIC you must insert a blank PIC to fill the empty slot and ensure proper c
44. NOS Release 8 1R1 Description Four DS3 ports Power requirement 0 41 A 48 V 20 0 W Intelligent queuing IQ PICs support fine grained queuing per logical interface ATM standards compliant Hardware features 16 MB SDRAM memory for ATM segmentation and reassembly SAR m ATM switch ID Configurable framing options a C bit with ATM direct mapping m C bit with Physical Layer Convergence Protocol PLCP framing default M23 ATM direct mapping m M23 with PLCP framing m Internal and loop timing 20 m ATM2 DS3 IQ PIC ATM2 DS3 IQ PIC Software features m Per virtual circuit VC and per virtual path VP traffic shaping m Unspecified bit rate UBR traffic shaping m Fine grained variable bit rate VBR traffic shaping m Circuit cross connect CCC m ATM Inverse Address Resolution Protocol ARP which enables routers to automatically learn the IP address of the router on the far end of an ATM permanent virtual circuit PVC m Simple Network Management Protocol SNMP L Management Information Base MIB 2 RFC 1213 m ATM MIB RFC 1695 m SONET MIB m AAL5 encapsulations m ATM VC MUX ATM NLPID m ATM Cisco LLPID m ATM SNAP m ATM CCC VC MUX Cables and connectors m 10 ft 3 05 m posilock SMB to BNC provided Four pairs of Rx and Tx coaxial cables LEDs One tricolor per port Off Not enabled Green Online with no alarms or failures Amber Online with alarms for remote failures
45. NOTE To extend the life of the laser when a PIC is not being actively used with any valid links take the PIC offline until you are ready to establish a link to another device For information about taking a PIC offline see the request chassis pic offline command in the JUNOS System Basics and Services Command Reference LEDs One tricolor per port m Off Not enabled E Green Online with no alarms or failures m Amber Online with alarms for remote failures m Red Active with a local alarm router has detected a failure 84 mm SONET SDH OC3c STM1 PIC Alarms errors and events SON SDH SONET SDH OC3c STM1 PIC ET alarms Alarm indication signal line AIS L Alarm indication signal path AIS P Bit error rate signal degrade BERR SD Bit error rate signal fail BERR SF Bit interleaved parity BIP error B1 Bit interleaved parity BIP error B2 Bit interleaved parity BIP error B3 Loss of frame LOF Loss of pointer LOP P Loss of signal LOS Far end bit error remote error indication line REI L CV LFE Far end bit error remote error indication path REI P CV PFE Payload mismatch path label mismatch PLM P Payload unequipped unequipped STS at path level UNEQ P Remote defect indication line RDI L Remote defect indication path RDI P alarms Multiplex section alarm indication signal MS AIS Administrative unit alarm indication signal AU AIS Bit error rate signal degrade
46. Network Address Translation NAT for IP 8 0R2 addresses Port Address Translation PAT for port numbers 8 0R2 IP Security IPSec encryption 8 0R2 7 Active flow monitoring exports cflowd version 8 0R2 E 5 and version 8 records Active flow monitoring exports flow monitoring 8 3 version 9 records based on RFC 3954 IP v4 templates only Passive flow monitoring a Passive flow collection z Flow tap 7 Dynamic flow capture Real time performance monitoring 8 3 Link services 8 0R2 8 0R2 Tunnel services 8 0R2 8 0R2 IP IP unicast tunneling GRE unicast tunneling Supports GRE fragmentation m Protocol Independent Multicast PIM sparse mode unicast tunneling Virtual tunnel interface for Layer 3 VPNs 8 0R2 Layer 2 Tunneling Protocol L2TP 8 0R2 8 0R2 Voice services 8 0R2 8 0R2 m Compressed Real Time Transport Protocol CRTP 18 Adaptive Services II Layer 2 Services PIC Adaptive Services II Layer 2 Services PIC Table 8 Adaptive Services PICs Software Features continued Encapsulations 8 0R2 Multilink Frame Relay MLFR Multilink Point to Point Protocol MLPP Adaptive Services II Layer 2 Services PIC m 19 M120 Internet Router PIC Guide ATM2 DS3 IQ PIC ps3 ATM2 aX gt 003154 Software release m JUNOS 8 0R2 and later Type 1 NOTE This PIC is not supported in JU
47. PID support on the 1 port 2 port and 4 port PICs m Source MAC learning on the 1 port 2 port and 4 port PICs m MAC accounting and policing Dynamic local address learning of source MAC addresses on the 1 port 2 port and 4 port PICs NOTE The 10 port Gigabit Ethernet PIC with SFP does not support MAC accounting and policing MAC learning TPID or flexible Ethernet encapsulation Cables and connectors You can install any transceiver supported by the PIC For information about installing and removing transceivers see the PIC and Transceiver Installation Instructions Fiber optic SFP transceivers m Duplex LC PC connector Rx and Tx m Optical interface support See Table 15 on page 62 1000Base T SFP transceivers m Connector Four pair Category 5 shielded twisted pair connectivity through an RJ 45 connector Pinout MDI crossover Length 328 ft 100 m NOTE Do not install Gigabit Ethernet SFPs in the SONET SDH port The port will not recognize the SFP Gigabit Ethernet PICs with SFP m 621 M120 Internet Router PIC Guide LEDs Status LED one bicolor m Off PIC is not enabled m Green PIC is operating normally m Red PIC has an error or failure Port LEDs one pair per port m Link If green the port is online if there is no light the port is down m Activity If flashing green the port is receiving data if there is no light the port might be on but is not receiving data Table 15
48. Red Active with a local alarm router has detected a failure Alarms errors and events Alarm indication signal AIS Far end block error FEBE Frame error dle code dle received Local and remote loopback Loss of signal LOS Out of frame OOF Path parity error Yellow alarm ATM2DS3 IQ PIC mm 21 M120 Internet Router PIC Guide ATM2 E3 IQ PIC g003157 Software release m JUNOS 8 0R2 and later Type 1 NOTE This PIC is not supported in JUNOS Release 8 1R1 Description Four E3 ports Power requirement 0 41 A 48 V 20 W Intelligent queuing IQ PICs support fine grained queuing per logical interface ATM standards compliant Hardware features m 16 MB SDRAM memory for ATM segmentation and reassembly SAR ATM switch ID Configurable framing options m G 751 direct mapping m G 751 with PLCP encapsulation default m G 832 ATM direct mapping m Internal and loop timing 22 m ATM2E31QPIC Software features ATM2 E3 IQ PIC Per virtual circuit VC and per virtual path VP traffic shaping Unspecified bit rate UBR traffic shaping Fine grained variable bit rate VBR traffic shaping Circuit cross connect CCC ATM Inverse Address Resolution Protocol ARP which enables routers to automatically learn the IP address of the router on the far end of an ATM permanent virtual circuit PVC Simple Network Management Protocol SNMP L Management In
49. S LFE UAS PFE m Loss of cell delineation LOC loss of frame LOF loss of pointer LOP P loss of signal LOS Payload mismatch PLM P payload unequipped UNEQ P Remote defect indication RDI L RDI P Severely errored framing SEF severely errored framing seconds SEFS S severely errored seconds SES S SES L SES P unavailable seconds UAS L UAS P Table 10 Optical Interface Support for ATM2 0C12 STM4 IQ PICs Parameter Intermediate Reach IR Transceiver Multimode Transceiver Optical interface Single mode Multimode Transceiver type Fixed Fixed 28 mm ATM20012 STM4 IQ PICs ATM2 0C12 STM4 IQ PICs Table 10 Optical Interface Support for ATM2 0C12 STM4 IQ PICs continued Parameter Intermediate Reach IR Transceiver Multimode Transceiver Standard Telcordia GR 253 Multivendor agreement Maximum distance 9 3 miles 15 km 546 8 yards 500 m Transmitter wavelength 1274 through 1356 nm 1270 through 1380 nm Average launch power 15 through 8 dBm 20 through 14 dBm Receiver saturation 8 dBm 14 dBm Receiver sensitivity 28 dBm 26 dBm ATM2 OC12 STM4 IQ PICS m 29 M120 Internet Router PIC Guide ATM2 0C48 STM16 IQ PIC with SFP 5 STM 16 Oc ATM a g002308 Software release JUNOS 8 0R2 and later Type 2 NOTE This PIC is not supported in JUNOS Release 8 1R1 Description One OC48 port Power requirement 0 41 A 48 V 20 W Intelligent queuing IQ PICs
50. able 29 on page 96 Table 30 on page 97 and Table 31 on page 97 NOTE To extend the life of the laser when a PIC is not being actively used with any valid links take the PIC offline until you are ready to establish a link to another device For information about taking a PIC offline see the request chassis pic offline command in the JUNOS System Basics and Services Command Reference LEDs One tricolor per port Off Not enabled Green Online with no alarms or failures Amber Online with alarms for remote failures Red Active with a local alarm router has detected a failure SONET SDH 0C12 STM4 Multi Rate PICs with SFP mg 95 M120 Internet Router PIC Guide Alarms errors and events SON SDH ET alarms Alarm indication signal line AIS L Alarm indication signal path AIS P Bit error rate signal degrade BERR SD Bit error rate signal fail BERR SF Bit interleaved parity BIP error B1 Bit interleaved parity BIP error B2 Bit interleaved parity BIP error B3 Loss of frame LOF Loss of pointer LOP P Loss of signal LOS Far end bit error remote error indication line REI L CV LFE Far end bit error remote error indication path REI P CV PFE Payload mismatch path label mismatch PLM P Payload unequipped unequipped STS at path level UNEQ P Remote defect indication line RDI L Remote defect indication path RDI P alarms Multiplex section alarm indication
51. ale m FX optical interface see Table 14 on page 59 12 port PIC m Connector One very High Density Connector Interface VHDCI to RJ 21 cable that connects to an RJ 45 patch panel 48 port PIC m VHDCI to RJ 21 cables that connect to an RJ 45 patch panel m Four VHDCI connectors that each service 12 10 100 ports NOTE Each of the four connectors on a Fast Ethernet 48 port PIC can support a maximum of approximately 800 Mbps However this constitutes oversubscription Use this PIC only in environments that can support this level of oversubscription LEDs Status LED one bicolor m Off PIC ports not enabled m Green PIC is operating normally m Red PIC has an error or failure 4 port PIC One pair of port LEDs m Link LED If green the port is online if there is no light the port is down m RXLED TIf flashing green the port is receiving data if there is no light the port might be on but is not receiving data 8 port PIC one pair of port LEDs per port m Port link LED If green the port is online if there is no light the port is down NOTE The Link LED remains lit on the 8 port PIC when the port is down m Port RX LED If flashing green the port is receiving data if there is no light the port might be on but is not receiving data 12 port PIC one port LED per port Green 100 Mbps link established Flashing green 100 Mbps activity Yellow 10 Mbps link established Flashing yellow 10 Mbps activ
52. ardware features Clear channel 34 368 Mbps and subrate E3 Unframed or ITU G 751 framing Data service unit DSU functionality Subrate and scrambling a Digital Link Quick Eagle E Kentrox HDB3 line encoding Full bit error rate test BERT Local and remote loopback testing 52 Em E3 IQ PIC Software features E3 IQ PIC Quality of service QoS per port weighted round robin WRR random early detection RED weighted random early detection WRED Simple Network Management Protocol SNMP E3 MIB QoS MIB Input policing and output shaping Provider side rate limiting Full data link connection identifier DLCI range with sparse channel numbering Per DLCI queues with weighted deficit round robin and strict priority Encapsulations High Level Data Link Control HDLC Frame Relay Circuit cross connect CCC Translational cross connect TCC Point to Point Protocol PPP JUNOS Release 7 0 or later is required to configure graceful Routing Engine switchover GRES Cables and connectors Standard E3 BNC coaxial cable interfaces LEDs On o tricolor per port Off Not enabled Green Online with no alarms or failures Amber Online with alarms for remote failures Red Active with a local alarm router has detected a failure Alarms errors and events Alarm indication signal AIS Equipment failure does not affect service Frame error Line code violation Loss of signal LOS
53. ation Encapsulations 1 High Level Data Link Control HDLC Frame Relay Circuit cross connect CCC Translational cross connect TCC Point to Point Protocol PPP Cables and connectors E Standard DS3 BNC coaxial cable interfaces LEDs One tricolor per port Off Not enabled Green Online with no alarms or failures Amber Online with alarms for remote failures Red Active with a local alarm router has detected a failure Alarms errors and events Alarm indication signal AIS Excessive zeros EXZ Far end block error FEBE Frame error dle code Idle received Line code violation LCV Loss of signal LOS Out of frame OOF Parity bit P bit disagreements Path parity error Yellow alarm bit X bit disagreements Instrumentation E counters Layer 2 per queue and per channel packet and byte counters 34 Em Channelized DS3 IQ PIC Channelized E1 IQ PIC Channelized E1 IQ PIC 9003040 Software release m JUNOS 8 0R2 and later Type 1 NOTE This PIC is not supported in JUNOS Release 8 1R1 Description m Ten El ports m Power requirement 0 15 A 48 V 7 2 W m Intelligent queuing IQ PICs support fine grained queuing per logical interface m Channelization E1 DSO Hardware features m Data service unit DSU functionality m Ports configurable as clear channel E1 interfaces with 2 048 Mbps connectivity
54. aved parity BIP error B3 Loss of frame LOF Loss of pointer LOP P Loss of signal LOS Far end bit error remote error indication line REI L CV LFE Far end bit error remote error indication path REI P CV PFE Payload mismatch path label mismatch PLM P Payload unequipped unequipped STS at path level UNEQ P Remote defect indication line RDI L Remote defect indication path RDI P arms ultiplex section alarm indication signal MS AIS Administrative unit alarm indication signal AU AIS Bit error rate signal degrade BERR SD Bit error rate signal fail BERR SF Bit interleaved parity BIP error B1 t interleaved parity BIP error B2 t interleaved parity BIP error B3 Loss of frame LOF Loss of pointer HP LOP Loss of signal LOS ultiplex section remote error indication MS RE igher path label mismatch HP PLM igher path unequipped HP UNEQ ultiplex section remote defect indication MS RDI igher path remote defect indication HP RDI m Errored seconds ES S ES L ES P far end errored seconds ES LFE ES PFE far end severe y errored seconds SES LFE SES PFE far end unavailable seconds UAS LFE UAS PFE E Severe y errored framing SEF severely errored framing seconds SEFS S severely errored seconds SES S SES L SES P unavailable seconds UAS L UAS P Table 36 Optical Interface Support for SONET SDH 0C192 PICs Parameter Short rea
55. ce Multimode Single mode Single mode Transceiver type SFP SFP SFP Maximum distance Standard Transmitter wavelength Average launch power Receiver saturation Receiver sensitivity MMF cable 1 2 miles 2 km Multivendor agreement 1270 through 1380 nm 20 through 14 dBm 14 dBm 30 dBm SMF cable 9 3 miles 15 km Telcordia GR 253 1261 through 1360 nm 15 through 8 dBm 8 dBm 28 dBm SMF cable 24 85 miles 40 km Telcordia GR 253 1263 through 1360 nm 5 through 0 dBm 10 dBm 34 dBm Table 30 Optical Interface Support for SONET SDH 0C12 STM4 Multi Rate PICs Configured at an 0C12 STM4 Rate Parameter Short Reach SR 1 Intermediate Reach IR 1 Long Reach LR 1 Transceiver model number Optical interface Transceiver type Maximum distance Standard Transmitter wavelength Average launch power Receiver saturation Receiver sensitivity SFP OC12 SR Single mode SFP SMF cable 1 24 miles 2 km Telcordia GR 253 1261 through 1360 nm 15 through 8 dBm 8 dBm 23 dBm SFP OC12 IR Single mode SFP SMF cable 9 3 miles 15 km Telcordia GR 253 1274 through 1356 nm 15 through 8 dBm 8 dBm 28 dBm SFP OC12 LR Single mode SFP SMF cable 24 85 miles 40 km Telcordia GR 253 1280 through 1335 nm 3 through 2 dBm 8 dBm 28 dBm Table 31 Optical Interface Support for SONET SDH 0C12 STM4 Multi Rate PICs Configured at an 0C48 STM16 Rate Paramet
56. ch SR 1 Intermediate Reach IR 2 Long Reach LR 2 Transceiver model number XFP 10G L OC192 SR1 XFP 10G E OC1 92 IR2 XFP 10G Z OC192 LR2 Optical interface Single mode Single mode Single mode 110 SONET SDH 0C192c STM64 PIC with XFP SONET SDH 0C192c STM64 PIC with XFP Table 36 Optical Interface Support for SONET SDH 0C192 PICs continued Parameter Short reach SR 1 Intermediate Reach IR 2 Long Reach LR 2 Transceiver type Standard Maximum distance Transmitter wavelength Average launch power Receiver saturation Receiver sensitivity XFP Telcordia GR 253 OC192 SR1 SME cable 6 21 miles 10 km 1290 nm through 1330 nm 6 through 1 dBm 1 0 dBm 11 dBm XFP Telcordia GR 253 OC192 IR2 SMF cable 24 8 miles 40 km distances greater than 30 km are considered to be engineered links 1530 nm through 1565 nm 1 0 through 2 dBm 1 0 dBm 14 dBm XFP Telcordia GR 253 OC192 LR2 SMF cable 49 71 miles 80 km 1530 nm through 1565 nm O through 4 dBm 7 dBm 24 dBm SONET SDH OC192c STM64 PIC with XFP mw 111 M120 Internet Router PIC Guide T1 PIC is aru C oto mN D sms O 5 O ront D lt Favs o D O port oe is m ponts 1 1387 Software release JUNOS 8 0R2 and later Type 1 NOTE This PIC is not supported in JUNOS Release 8 1R1 Description m Four T1 ports E Power requirement 0
57. cordia GR 253 9 3 miles 15 km 1274 through 1356 nm 15 through 8 dBm 8 dBm 28 dBm 42 a Channelized OC12 IQ PIC Channelized STM1 IQ PIC Channelized STM1 IQ PIC Software release JUNOS 8 0R2 and later Type 1 NOTE This PIC is not supported in JUNOS Release 8 1R1 Description One STM1 port Power requirement 0 39 A 48 V 18 6 W Intelligent queuing IQ PICs support fine grained queuing per logical interface Channelization STMIc fractional E1 framed and unframed DSO Hardware features Packet buffering Layer 2 parsing Local and remote loopback testing Software features Quality of service QoS per channel weighted round robin WRR random early detection RED weighted random early detection WRED SNMP SONET SDH MIB T1 E1 MIB Dynamic arbitrary channel configuration Full bit error rate test BERT patterns at E1 and DSO levels Encapsulations High Level Data Link Control HDLC Frame Relay Circuit cross connect CCC Translational cross connect TCC Point to Point Protocol PPP Cables and connectors Duplex SC PC connector Rx and Tx single mode intermediate reach fiber LEDs One tricolor per port Off Not enabled Green Online with no alarms or failures Amber Online with alarms for remote failures Red Active with a local alarm router has detected a failure Channelized STM11Q PIC m 43 M120 Internet Router PIC Guide
58. de Depending on your JUNOS release and individual licenses software features for this PIC can include Stateful firewall with packet inspection m Detects SYN attacks ICMP and UDP floods and ping of death attacks NAT for IP addresses Port Address Translation PAT for port numbers J Flow accounting exports cflowd version 5 and version 8 records Tunnel services a IP IP unicast tunneling m GRE unicast tunneling Supports GRE fragmentation m PIM sparse mode unicast tunneling m Virtual tunnel interface for Layer 3 VPNs IPSec encryption Voice services m Compressed Real Time Protocol CRTP Encapsulations a Multilink Frame Relay MLFR a Multilink Point to Point Protocol MLPP LEDs Status LED one tricolor m Off PIC is offline and it is safe to remove it from the chassis m Green PIC is operating normally m Amber PIC is initializing m Red PIC has an error or failure and no further harm can be done by removing it from the chassis Application LED one tricolor m Off Service is not running m Green Service is running under acceptable load m Amber Service is overloaded 16 Adaptive Services II FIPS PIC Adaptive Services II Layer 2 Services PIC Adaptive Services Il Layer 2 Services PIC STATUg T app Q Pe Le OL TT aT p q A PODON HHH ma a _ _ 002318 Software release m JUNOS 8 0R2 and later Type 1 NOTE This PIC is not supported in
59. dication signal AIS L AIS P Bit error rate signal degrade BERR SD bit error rate signal fail BERR SF Bit interleaved parity errors B1 B2 B3 CV S CV L CV P Errored seconds ES S ES L ES P far end bit errors REI L REI P CV LFE CV PFE far end block error FEBE far end errored seconds ES LFE ES PFE far end severely errored seconds SES LFE SES PFE far end unavailable seconds UAS LFE UAS PFE Frame error dle code Idle received Loss of frame LOF loss of pointer LOP P loss of signal LOS Out of frame OOF Payload mismatch PLM P payload unequipped UNEQ P Parity bit P bit disagreements Path parity error Remote defect indication RDI L RDI P Severely errored framing SEF severely errored framing seconds SEFS S severely errored seconds SES S SES L SES P unavailable seconds UAS L UAS P Yellow alarm bit X bit disagreements Instrumentation counters Layer 2 per queue and per channel packet and byte counters Table 13 Optical Interface Support for Channelized 0C12 IQ PICs Parameter Intermediate Reach IR Optical interface Single mode Channelized OC12 IQ PIC mgm 42 M120 Internet Router PIC Guide Table 13 Optical Interface Support for Channelized OC12 IQ PICs continued Parameter Intermediate Reach IR Standard Maximum distance Transmitter wavelength Average launch power Receiver saturation Receiver sensitivity Tel
60. e port is down m RX If flashing green the port is receiving data if there is no light the port might be on but is not receiving data Table 19 Optical Interface Support for 10 Gigabit Ethernet PICs with XENPAK Parameter Short Wavelength Serial LOGBase SR LAN Rate Long Wavelength Serial LOGBase LR LAN Rate Extra Long Wavelength Serial LOGBase ER LAN Rate Extra Long Wavelength Serial 1OGBase ZR LAN Rate Transceiver model number Optical interface Transceiver type Standard Maximum distance Transmitter wavelength Average launch power 74 m XENPAK 1 XGE SR Multimode XENPAK module IEEE 802 3ae 2002 50 125 MMF cable 2000 MHz km 984 feet 300 m 50 125 MMF cable 500 MHz km 269 feet 82 m 50 125 MMF cable 400 MHz km 217 feet 66 m 62 5 125 MMF cable 200 MHz km 108 feet 33 m 62 5 125 MMF cable 160 MHz km 85 feet 26 m 840 nm through 860 nm 4 5 through 1 dBm 10 Gigabit Ethernet PIC with XENPAK XENPAK 1 XGE LR Single mode XENPAK module IEEE 802 3ae 2002 9 125 SMF cable 6 2 miles 10 km 1260 through 1355 nm 4 through 0 5 dBm XENPAK 1 XGE ER Single mode XENPAK module IEEE 802 3ae 2002 9 125 SMF cable 24 8 miles 40 km Distances greater than 30 km are considered to be engineered links 1530 through 1565 nm 4 7 through 4 dBm XENPAK 1 XGE ZR Single mode XENPAK module Multivendor agreement 9 125
61. e signal degrade BERR SD Bit error rate signal fail BERR SF Bit interleaved parity BIP error B1 Bit interleaved parity BIP error B2 Bit interleaved parity BIP error B3 Loss of frame LOF Loss of pointer HP LOP Loss of signal LOS Multiplex section remote error indication MS RE I Higher path label mismatch HP PLM Higher path unequipped HP UNEQ Multiplex section remote defect indication MS RDI Higher path remote defect indication HP RDI Errored seconds ES S ES L ES P far end errored seconds ES LFE ES PFE far end severely errored seconds SES LFE SES PFE far end unavailable seconds UAS LFE UAS Seve PFE ely errored framing SEF severely errored framing seconds SEFS S severely errored seconds SES S SES L SES P unavailable seconds UAS L UAS P Table 33 Optical Interface Support for SONET SDH O0C48 STM16 Multi Rate PICs Configured at an 0C3 STM1 Rate Parameter Multimode Intermediate Reach IR 1 Long Reach LR 1 Transceiver model SFP OC3 SR SFP OC3 IR SFP OC3 LR number SONET SDH 0C48 STM16 Multi Rate PIC with SFP mg 105 M120 Internet Router PIC Guide Table 33 Optical Interface Support for SONET SDH O0C48 STM16 Multi Rate PICs Configured at an OC3 STM1 Rate continued Parameter Multimode Intermediate Reach IR 1 Long Reach LR 1 Optical interface Multimode Single mode Single mode Transceiver type SFP SFP SFP Maximum distance Sta
62. e support See Table 17 on page 69 m Copper 1000Base T SFPs m Connector Four pair Category 5 shielded twisted pair connectivity through an RJ 45 connector Pinout MDI crossover m Length 328 ft 100 m LEDs OK or Status LED one tricolor Off PIC is offline and it is safe to remove it from the router Green PIC is operating normally Amber PIC is initializing Red PIC has an error or failure APP LED one bicolor m Off Monitoring application is not running m Green Monitoring application is running under acceptable load Port LEDs one per port m Off Port is not enabled m Green Port is online with no alarms or failures 68 Gigabit Ethernet 1Q2 PICs with SFP Gigabit Ethernet IQ2 PICs with SFP Table 17 Optical Interface Support for Gigabit Ethernet IQ2 PICs with SFP Parameter 1000Base SX 1000Base LX 1000Base LH Optical interface Multimode Single mode Single mode Transceiver type SFP SFP SFP Standard IEEE 802 3 1998 IEEE 802 3 1998 Multivendor agreement Maximum distance Transmitter wavelength Average launch power Average receive power Receiver saturation Receiver sensitivity 62 5 125 MMF cable 656 ft 200 m 50 125 MMF cable 1640 ft 500 m 770 through 860 nm 9 5 through 0 dBm 17 through 0 dBm 0 dBm 17dBm 9 125 SMF cable 6 2 miles 10 km 62 5 125 or 50 125 MME cable 1804 5 ft 550 m 1270 through 1355 nm 11 5 through
63. ed by the PIC For information about installing and removing transceivers see the PIC and Transceiver Installation Instructions m Duplex LC PC connector Rx and Tx m Optical interface support See Table 26 on page 89 and Table 27 on page 90 NOTE To extend the life of the laser when a PIC is not being actively used with any valid links take the PIC offline until you are ready to establish a link to another device For information about taking a PIC offline see the request chassis pic offline command in the JUNOS System Basics and Services Command Reference LEDs One tricolor per port m Off Not enabled E Green Online with no alarms or failures m Amber Online with alarms for remote failures m Red Active with a local alarm router has detected a failure 88 m SONET SDH 0C3 STM1 Multi Rate PICs with SFP Alarms errors and events SON SDH SONET SDH OC3 STM1 Multi Rate PICs with SFP ET alarms Alarm indication signal line AIS L Alarm indication signal path AIS P Bit error rate signal degrade BERR SD Bit error rate signal fail BERR SF Bit interleaved parity BIP error B1 Bit interleaved parity BIP error B2 Bit interleaved parity BIP error B3 Loss of frame LOF Loss of pointer LOP P Loss of signal LOS Far end bit error remote error indication line REI L CV LFE Far end bit error remote error indication path REI P CV PFE Payload mismatch path label mismatch PLM
64. en Omg z een 0 1S OO s ofp 0 oune Lill T OO KER 0 PSE ail B 0 0 aS lo go OG LA L Ls 0 0 Sa eim d Oe Maen 7 3 Onn al T ane Left 4 Port Gigabit Ethernet PIC Right 10 Port Gigabit Ethernet PIC 60 Gigabit Ethernet PICs with SFP 002116 Software release Gigabit Ethernet PICs with SFP 1 port JUNOS 8 0R2 and later Type 1 2 port JUNOS 8 0R2 and later Type 2 4 port JUNOS 8 0R2 and later Type 2 10 port JUNOS 8 0R2 and later Type 3 NOTE These PICs are not supported in JUNOS Release 8 1R1 Description One two four or ten Gigabit Ethernet ports m Power requirement port 0 15 A 48 V 7 3 W m 2 port 0 25 A 48 V 11 9 W m 4 port 0 50 A 48 V 23 8 W 10 port 0 62 A 48 V 29 9 W m Supports large Ethernet frame sizes for more efficient throughput across the intra POP network Hardware features m High performance throughput on each port at speeds up to 1 Gbps m Autonegotiation between Gigabit Ethernet circuit partners m Full duplex mode m Maximum transmission units MTUs of up to 9192 bytes Software features m Virtual Router Redundancy Protocol VRRP support m 802 1q virtual LANs VLANs support m 960 destination MAC filters per port m Optical diagnostics and related alarms on the 2 port 4 port and 10 port PICs UNOS 8 2 and later m Flexible Ethernet encapsulation on the 1 port 2 port and 4 port PICs m Multiple tag protocol identifiers T
65. er Short Reach SR 1 Intermediate Reach IR 1 Long Reach LR 2 Transceiver model number Optical interface SFP OC48 SR Single mode SFP OC48 IR Single mode SFP OC48 LR Single mode SONET SDH 0C12 STM4 Multi Rate PICs with SFP mg 97 M120 Internet Router PIC Guide Table 31 Optical Interface Support for SONET SDH 0C12 STM4 Multi Rate PICs Configured at an 0C48 STM16 Rate continued Parameter Short Reach SR 1 Intermediate Reach IR 1 Long Reach LR 2 Transceiver type Maximum distance Standard Transmitter wavelength Average launch power Receiver saturation Receiver sensitivity SFP SMF cable 1 24 miles 2 km Telcordia GR 253 1266 through 1360 nm 10 through 3 dBm 3 dBm 18 dBm SFP SMF cable 9 3 miles 15 km Telcordia GR 253 1260 through 1360 nm 5 through 0 dBm 0 dBm 18 dBm SFP SMF cable 49 71 miles 80 km Telcordia GR 253 1500 through 1580 nm 2 through 3 dBm 9 dBm 28 dBm 98 m SONET SDH 0C12 STM4 Multi Rate PICs with SFP SONET SDH OC48c STM16 PIC with SFP SONET SDH OC48c STM16 PIC with SFP Mg Oc Sone gee ONLINE OFF 0140d RX ity Stug Status Rx ITX 1 140d RX yTy Statyg Status RX Ty b1u0d Z140d LSSI o g001886 Software release m JUNOS 8 0R2 and later NOTE This PIC is not supported in JUNOS Release 8 1R1 Description m Four OC4
66. formation Base MIB 2 RFC 1213 E ATM MIB RFC 1695 E SONET MIB AAL5 encapsulations m ATM VC MUX ATM NLPID ATM Cisco LLPID ATM SNAP ATM CCC VC MUX Cables and connectors 10 ft 3 05 m posilock SMB to BNC provided Four pairs of Rx and Tx coaxial cables LEDs One tricolor per port Off Not enabled Green Online with no alarms or failures Amber Online with alarms for remote failures Red Active with a local alarm router has detected a failure Alarms errors and events Alarm indication signal AIS Frame error Line code violation Local and remote loopback Loss of signal LOS Out of frame OOF Yellow alarm ATM2E3IQPIC m 23 M120 Internet Router PIC Guide ATM2 OC3 STM1 IQ PIC aS 1848 Software release C JUNOS 8 0R2 and later Type 1 NOTE This PIC is not supported in JUNOS Release 8 1R1 Description Two OC3 ports Power requirement 0 41 A 48 V 20 W Intelligent queuing IQ PICs support fine grained queuing per logical interface Conforms to ANSI T1 105 1991 and T1E1 2 93 020R1 ATM and SONET SDH standards compliant Alarm and event counting and detection Compatible with well known ATM switches ATM switch ID which displays the switch IP address and local interface name of the adjacent Fore ATM switches Hardware features Single 3010 SAR for segmentation and reassembly into 53 byte ATM cells High performance parsing of
67. hotodiode APD Jitter tolerance compliance GR 53 G 8251 802 3ae LAN PHY Rx DTV setting Auto Rx wavelength range 1527 to 1567 nm Overload 5 dBm Damage input power 5 dBm Optical return loss 27 dB Optical performance Optical Applications Power Limited Receiver m Sensitivity 28 dBm gt 33dB 0 1 nm OSNR 0 ps nm CD 10 5 post FEC BER m Chromatic dispersion CD power penalty 3 dB typical penalty at 1600 ps nm and 700 ps nm CD Optical Applications Noise Limited Receiver m Required OSNR 16 dB O 1 nm 8 to 20 dBm Rx input power 0 ps nm CD 107 15 post FEC BER m CD OSNR penalty 4 dB typical penalty at 1500 ps nm and 700 ps nm CD with Rx input power from 8 to 20 dBm For more detailed information see Table 21 on page 76 Table 21 XENPAK OTN Optical Signal to Noise Ratio OSNR Performance OSNR dB 0 1 OSNR dB 0 5 FEC Type Pre FEC Post FEC Input Power CD Tolerance nm nm BER BER Range ps nm dBm 33 26 GFEC 10 5 10715 5 to 28 o 33 26 GFEC 1075 10715 5 to 26 700 to 1600 16 9 GFEC 10 5 10715 8 to 20 o 76 m 10 Gigabit Ethernet PIC with XENPAK 10 Gigabit Ethernet PIC with XENPAK Table 21 XENPAK OTN Optical Signal to Noise Ratio OSNR Performance continued OSNR dB 0 1 OSNR dB 0 5 FEC Type Pre FEC Post FEC Input Power CD Tolerance nm nm BER BER Range ps nm dBm 17 10 GFEC 1075 10715 8 to 20 400 to 800
68. ingle mode XFP Telcordia GR 253 OC192 IR2 FPCs and cFPCs Supported XFP 10G Z OC192 LR2 Single mode XFP Telcordia GR 253 OC192 LR2 a 7 M120 Internet Router PIC Guide Table 5 Optical Interface Support for SONET SDH 0C192 STM64 cFPC continued Parameter Short reach SR 1 Intermediate reach IR 2 Long Reach LR 2 Maximum distance Transmitter wavelength Average launch power Receiver saturation Receiver sensitivity SMF cable 6 21 miles 10 km 1290 through 1330 nm 6 through 1 dBm 1 0 dBm 11 dBm SMF cable 24 8 miles 40 km distances greater than 30 km are considered to be engineered links 1530 through 1565 nm 1 0 through 2 dBm 1 0 dBm 14 dBm SMF cable 49 71 miles 80 km 1530 through 1565 nm 0 through 4 dBm 7 dBm 24 dBm 8 m_ FPCsandcFPCs Supported PIC FPC Compatibility PIC FPC Compatibility Table 6 on page 9 provides a PIC FPC compatibility matrix for the supported PICs for the M120 router Table 6 M120 PIC FPC Compatibility PIC Type Number of Ports PIC Model Number FPC1 FPC2 FPC3 ATM2 IQ PICs ATM2 DS3 IQ 4 PB 4DS3 ATM2 8 0R2 ATM2 E3 IQ 4 PB 4E3 ATM2 8 0R2 ATM2 OC3 STM1 IQ PB 20C3 ATM2 MM 2 8 0R2 PB 20C3 ATM2 SMIR ATM2 OC12 STM4 IQ PB 10C12 ATM2 MM 1 8 0R2 PB 10C12 ATM2 SMIR ATM2 OC12 STM4 IQ PB 20C12 ATM2 MM 2 8 0R2 PB 20C12 ATM2 SMIR ATM2 OC48 STM1
69. ity Off No link present NOTE The port LEDs remains lit on the 12 port PIC when the ports are down 58 Fast Ethernet PICs Fast Ethernet PICs 48 port PIC does not have port LEDs To check port status on a 48 port PIC use the show interfaces fe fpc pic port command For more information about this command see the JUNOS Network Interfaces Configuration Guide Table 14 Optical Interface Support for Fast Ethernet PICs Parameter FX Interface for 8 Port Optical interface Multimode Maximum distance 62 5 125 MMF cable 1 24 miles 2 km Wavelength 1 270 to 1 380 nm Average launch power 20 to 14 dBm Receiver saturation 14dBm Receiver sensitivity 34 dBm Fast Ethernet PICs m 59 M120 Internet Router PIC Guide Gigabit Ethernet PICs with SFP RR v c Ethem ow 02207 x p TABASE gpp Sa a f ep 1000c emet ri g J L D Joam D BASE x SEP le 02 p i 3 i 5 Qonun ae p ae gmr Gae g ooj 3 a a S syg 2 P o a c fo p o 7 J PORT faa SAN 66 re SS PORT TA B 0 STaTUg Left 1 Port Gigabit Ethernet PIC Right 2 Port Gigabit Ethernet PIC roogneet SFP ey E ee n TT he p ther O r lal 0 ro alha 100084 met mei lgl D skl SEX Spp eo le a of PY Meot o fo all oO sms EBL Le F
70. iver model number Optical interface 106 m SFP OC48 SR Single mode SONET SDH 0C48 STM16 Multi Rate PIC with SFP SFP OC48 IR Single mode SFP OC48 LR Single mode SONET SDH 0C48 STM16 Multi Rate PIC with SFP Table 35 Optical Interface Support for SONET SDH O0C48 STM16 Multi Rate PICs Configured at an 0C48 STM16 Rate continued Parameter Short Reach SR 1 Intermediate Reach IR 1 Long Reach LR 2 Transceiver type Maximum distance Standard Transmitter wavelength Average launch power Receiver saturation Receiver sensitivity SFP SMF cable 1 24 miles 2 km Telcordia GR 253 1266 through 1360 nm 10 through 3 dBm 3 dBm 18 dBm SFP SMF cable 9 3 miles 15 km Telcordia GR 253 1260 through 1360 nm 5 through 0 dBm 0 dBm 18 dBm SFP SMF cable 49 71 miles 80 km Telcordia GR 253 1500 through 1580 nm 2 through 3 dBm 9 dBm 28 dBm SONET SDH 0C48 STM16 Multi Rate PIC with SFP m 107 M120 Internet Router PIC Guide SONET SDH 0C192c STM64 PIC with XFP STATUS ONUNey OFFLINE Software release m JUNOS 8 3 and later Type 3 Description m One 0C192 port Power requirement 0 52A 48 V 25 W Hardware features m Multiplexing and demultiplexing m Rate policing on input m Rate shaping on output m Packet buffering Layer 2 parsing Software features m SONET SDH framing m Link aggregation m Alarm and e
71. ized T1 IQ PIC m 45 M120 Internet Router PIC Guide Hardware features Data service unit DSU and channel service unit CSU functionality Ports configurable as clear channel T1 interfaces with 1 544 Mbps connectivity Framing Superframe SF or D4 and Extended Superframe ESF Supports B8ZS bipolar 8 zero substitution and AMI alternate mark inversion line coding Local remote and payload loopback testing ANSI T1 403 loopback support m Responds to embedded loopback commands upon receipt of an FDL command from remote end with loopup and loopdown at both line and payload level m nsertion of loopback commands enables remote CSU NIU Smartjack to enter oopback and loopdown at both the line and payload level ANSI and Telcordia m Inband loopback support m Responds to inband loopback commands at both the line and payload level ANSI and Telcordia m nsertion of inband loopback commands at both the line and payload level ANSI and Telcordia Clocking support of external line and internal Buildout support of the following ranges m O through 132 Line buildout is from 1 through 132 feet m 133 through 265 Line buildout is from 133 through 265 feet 266 through 398 Line buildout is from 266 through 398 feet m 399 through 531 Line buildout is from 399 through 531 feet m 532 through 655 Line buildout is from 532 through 655 feet Software features m Quality of service QoS per channel weighted round robin
72. l alarm router has detected a failure Alarms errors and events Alarm indication signal AIS L AIS P Bit error rate signal degrade BERR SD bit error rate signal fail BERR SF Bit interleaved parity errors B1 B2 B3 Errored seconds ES S ES L ES P far end bit errors REI L REI P CV LFE CV PFE far end errored seconds ES LFE ES PFE far end severely errored seconds SES LFE SES PFE far end unavailable seconds UAS LFE UAS PFE m Loss of cell delineation LOC loss of frame LOF loss of pointer LOP P loss of signal LOS m Payload mismatch PLM P payload unequipped UNEQ P Remote defect indication RDI L RDI P Severely errored framing SEF severely errored framing seconds SEFS S severely errored seconds SES S SES L SES P unavailable seconds UAS L UAS P Table 9 Optical Interface Support for ATM2 OC3 IQ PICs Parameter Intermediate Reach IR Multimode Optical interface Single mode Multimode Transceiver type Fixed Fixed ATM2 0C3 STM1 IQ PIC m 25 M120 Internet Router PIC Guide Table 9 Optical Interface Support for ATM2 OC3 IQ PICs continued Parameter Intermediate Reach IR Multimode Standard Maximum distance Transmitter wavelength Average launch power Receiver saturation Receiver sensitivity Telcordia GR 253 9 3 miles 15 km 1260 through 1360 nm 15 through 8 dBm 8 dBm 28 dBm Multivendor agreement 1 2 miles 2 km 1270 through
73. lease m JUNOS 8 0R2 and later Type 1 NOTE This PIC is not supported in JUNOS Release 8 1R1 Description One OC12 port Power requirement 0 23 A 48 V 10 8 W Intelligent queuing IQ PICs support fine grained queuing per logical interface Channelization OC3 DS3 DS1 DSO Hardware features m Subrate and scrambling m Digital Link Quick Eagle Kentrox Larscom ADTRAN Verilink Packet buffering Layer 2 parsing M13 C bit parity encoding DS3 far end alarm and control FEAC channel support Local and remote loopback testing 40 gm Channelized 0C12 IQ PIC Software features Channelized OC12 IQ PIC Quality of service QoS per channel weighted round robin WRR random early detection RED weighted random early detection WRED Simple Network Management Protocol SNMP OC3 MIB DS3 MIB T1 MIB Dynamic arbitrary channel configuration Full bit error rate test BERT Encapsulations a High Level Data Link Control HDLC Frame Relay Circuit cross connect CCC Translational cross connect TCC Point to Point Protocol PPP Cables and connectors Duplex SC PC connector Rx and Tx single mode fiber Optical interface support See Table 13 on page 41 LEDs One tricolor per port Off Not enabled Green Online with no alarms or failures Amber Online with alarms for remote failures Red Active with a local alarm router has detected a failure Alarms errors and events Alarm in
74. lor m Off Not enabled E Green Online with no alarms or failures m Amber Online with alarms for remote failures m Red Active with a local alarm router has detected a failure NOTE The green status LED is lit on the 2 port Gigabit Ethernet IQ PIC when at least one port is online Port LEDs one per port m Off Port is down m Green Link is established Table 16 Optical Interface Support for Gigabit Ethernet IQ PICs with SFP Parameter 1000Base SX 1000Base LX 1000Base LH Optical interface Multimode Single mode Single mode Transceiver type SFP SFP SFP Standard IEEE 802 3 1998 IEEE 802 3 1998 Multivendor agreement Maximum distance 62 5 125 MMF cable 9 125 SMF cable 9 125 SMF cable 656 ft 200 m 6 2 miles 10 km 43 5 miles 70 km 50 125 MMF cable 62 5 125 or 50 125 1640 ft 500 m MME cable 1804 5 ft 550 m Transmitter 770 through 860 nm 1270 through 1355 1480 through 1580 wavelength nm nm Average launch power 9 5 through 0 dBm 11 5 through 3 3 through 3 dBm dBm 64 Gigabit Ethernet IQ PICs with SFP Gigabit Ethernet IQ PICs with SFP Table 16 Optical Interface Support for Gigabit Ethernet IQ PICs with SFP continued Parameter 1000Base SX 1000Base LX 1000Base LH Average receive power Receiver saturation Receiver sensitivity 17 through 0 dBm 19 through 3 dBm 20 through 3 dBm 0 dBm 3 dBm 3 dBm 17dBm 19 dBm 20 dBm Gigabit Ethernet IQ PICs with SFP m 65 M120 Internet Router PIC Guide
75. m Supports unframed E1 G 703 and G 704 framing modes m Supports HDB3 line coding m CRC4 configurable m Local and remote loopback testing Software features m Quality of service QoS per channel weighted round robin WRR random early detection RED weighted random early detection WRED m Simple Network Management Protocol SNMP E1 MIB DSO MIB m Dynamic arbitrary channel configuration m Full bit error rate test BERT m Encapsulations E High Level Data Link Control HDLC Frame Relay Circuit cross connect CCC Translational cross connect TCC Point to Point Protocol PPP Channelized E1 IQ PIC m 35 M120 Internet Router PIC Guide Cables and connectors m 120 ohm RJ 48C LEDs One bicolor per E1 port m Off Port not enabled m Green Physical E1 link is up individual subchannels can be down m Red Physical E1 link is down Alarms errors and m Alarm indication signal AIS events m Loss of frame LOF m Out of frame OOF m Failed signal rate FSR Instrumentation m Layer 2 per queue and per channel packet and byte counters counters 36 mm Channelized E1 IQ PIC Channelized OC3 IQ PIC Channelized OC3 IQ PIC Software release m JUNOS 8 0R2 and later Type 1 NOTE This PIC is not supported in JUNOS Release 8 1R1 Description One OC3 port Power requirement 0 39 A 48 V 8 6 W Intelligent queuing IQ PICs support fine grained queuing per logical
76. m can be done by removing it from the chassis Application LED one bicolor m Off Service is not running m Green Service is running under acceptable load m Amber Service is overloaded Table 24 MultiServices PICs Software Features Supported on the M120 Router Software Feature MultiServices 100 MultiServices 400 MultiServices 500 GRE Key GRE dont fragment MultiServices PICs m 821 M120 Internet Router PIC Guide Table 24 MultiServices PICs Software Features Supported on the M120 Router continued Stateful firewall with packet inspection detects SYN 8 2R2 8 2 8 3 attacks ICMP and UDP floods and ping of death attacks Network Address Translation NAT for IP addresses 8 2R2 8 2 8 5 Port Address Translation PAT for port numbers 8 2R2 8 2 8 3 IP Security IPSec encryption 8 2R2 8 2 8 5 Active flow monitoring exports cflowd version 5 and 8 2R2 8 2 8 3 version 8 records Active flow monitoring exports flow monitoring version 8 3 8 5 8 5 9 records based on RFC 3954 Passive flow monitoring 8 4 Passive flow collection 8 5 Flow tap 8 2R2 8 2 8 5 Dynamic flow capture 8 4 Real time Performance Monitoring 8 2R2 8 2 8 5 Link services 8 2R2 8 2 8 5 Tunnel services 8 2R2 8 2 8 3 IP IP unicast tunneling GRE unicast tunneling Supports GRE fragmentation m Protocol Independent Multicast PIM sparse mode unicast tunneling
77. marks service marks registered trademarks or registered service marks are the property of their respective owners Juniper Networks assumes no responsibility for any inaccuracies in this document Juniper Networks reserves the right to change modify transfer or otherwise revise this publication without notice Products made or sold by Juniper Networks or components thereof might be covered by one or more of the following patents that are owned by or licensed to Juniper Networks U S Patent Nos 5 473 599 5 905 725 5 909 440 6 192 051 6 333 650 6 359 479 6 406 312 6 429 706 6 459 579 6 493 347 6 538 518 6 538 899 6 552 918 6 567 902 6 578 186 and 6 590 785 M120 Internet Router PIC Guide Copyright 2008 Juniper Networks Inc All rights reserved Printed in USA Writing Charissa Fleischer Elizabeth Gardner Editing Stella Hackell Illustration Faith Bradford Brown Cover Design Edmonds Design Revision History 10 March 2008 530 024399 01 Revision 1 Added new transceiver XENPAK OTN for 10 Gigabit Ethernet PIC with XENPAK 1 February 2008 530 022467 01 Revision 2 Removed SONET SDH OC3c STM1 PIC SMF IR SONET SDH OC12c STM4 PIC SMF IR SONET SDH OC12c STM4 PIC MM and SONET SDH OC48c STM16 PIC with SFP 15 September 2007 530 022467 01 Revision 1 Added 8 port Gigabit Ethernet IQ2 Type 3 PIC Removed SONET SDH OC1 92c STM64 PIC 29 June 2007 530 020809 01 Revision 1 Added SONET SDH OC3 STM1 and OC12c
78. mum transmission units MTUs of up to 9192 bytes Gigabit Ethernet IQ2 PICs with SFP mm 67 M120 Internet Router PIC Guide Software features Intelligent handling of oversubscribed traffic for Type 1 and Type 2 PICs Optical diagnostics and related alarms m Quality of service QoS per channel weighted round robin WRR random early detection RED weighted random early detection WRED Virtual Router Redundancy Protocol VRRP support Hierarchical shaping Fine grained queuing and shaping per logical interface at both ingress and egress 802 1q virtual LANs VLANs VLAN stacking and rewriting Channels defined by two stacked VLAN tags Point to Point Protocol over Ethernet PPPoE over VLAN JUNOS Release 8 5 and later Multiple tag protocol identifiers TPID support IP service for nonstandard TPID and stacked VLAN tags 802 1p rewrite per channel Flexible mapping of channels and scheduler resources at both ingress and egress Flexible Ethernet encapsulation MAC learning policing accounting and filtering Cables and connectors m You can install any transceiver supported by the PIC For information about installing and removing transceivers see the PIC and Transceiver Installation Instructions NOTE Do not install SONET SDH SFPs in the Gigabit Ethernet port The port will not recognize the SFP m Fiber optic small form factor pluggable transceivers SFPs m Duplex LC PC connector Rx and Tx m Optical interfac
79. nd receive normal traffic Equipment failure does not affect service Far end block error FEBE Frame error Idle code Idle received Local and remote loopback Loss of signal LOS Out of frame OOF Parity bit P bit disagreements Path parity error Yellow alarm bit X bit disagreements DS3 PIC m 49 M120 Internet Router PIC Guide E1 PICs o War Og ooo D g sus P b 1 pont g oleae port Jo dg Fras 5 o port D D s a Pa ports ao O LD De oma BOE l On Left E1 RJ 48 PIC Right E1 Coaxial PIC Software release m JUNOS 8 0R2 and later Type 1 NOTE These PICs are not supported in JUNOS Release 8 1R1 Description m Four E1 or coaxial ports Power requirement 0 08 A 48 V 3 74 W Two versions m 4 port 120 ohm RJ 48 m 4 port 75 ohm coaxia m Onboard DSU functionality for E1 connectivity Hardware features High performance throughput on each port at speeds up to 2 048 Mbps full duplex Maximum transmission units MTUs of up to 4500 bytes Per interface diagnostics and loopback control Per interface shaping on output Per interface alarm and event counting and detection HDB3 line coding 4 bit CRC for G 704 framed mode Per port loop timing Balanced and unbalanced modes Packet buffering Layer 2 parsing Full bit error rate test BERT 50 mm E E1PICs Software features E1 PICs Integrated support for G 703 u
80. ndard Transmitter wavelength Average launch power Receiver saturation Receiver sensitivity MMF cable 1 2 miles 2 km Multivendor agreement 1270 through 1380 nm 20 through 14 dBm 14 dBm 30 dBm SMF cable 9 3 miles 15 km Telcordia GR 253 1261 through 1360 nm 15 through 8 dBm 8 dBm 28 dBm SMF cable 24 85 miles 40 km Telcordia GR 253 1263 through 1360 nm 5 through 0 dBm 10 dBm 34 dBm Table 34 Optical Interface Support for SONET SDH O0C48 STM16 Multi Rate PICs Configured at an 0C12 STM4 Rate Parameter Short Reach SR 1 Intermediate Reach IR 1 Long Reach LR 1 Transceiver model number Optical interface Transceiver type Maximum distance Standard Transmitter wavelength Average launch power Receiver saturation Receiver sensitivity SFP OC12 SR Single mode SFP SMF cable 1 24 miles 2 km Telcordia GR 253 1261 through 1360 nm 15 through 8 dBm 8 dBm 23 dBm SFP OC12 IR Single mode SFP SMF cable 9 3 miles 15 km Telcordia GR 253 1274 through 1356 nm 15 through 8 dBm 8 dBm 28 dBm SFP OC12 LR Single mode SFP SMF cable 24 85 miles 40 km Telcordia GR 253 1280 through 1335 nm 3 through 2 dBm 8 dBm 28 dBm Table 35 Optical Interface Support for SONET SDH OC48 STM16 Multi Rate PICs Configured at an 0C48 STM16 Rate Parameter Short Reach SR 1 Intermediate Reach IR 1 Long Reach LR 2 Transce
81. ne t BASE DWoy 9 DD lt Y g002305 Software release JUNOS 8 0R2 and later Type 3 NOTE This PIC is not supported in JUNOS Release 8 1R1 Description One 10 Gigabit Ethernet port Power requirement 0 55 A 48 V 26 6 W Supports large Ethernet frame sizes for more efficient throughput across the intra POP network Hardware features C band ITU Grid with 100 GHz spacing High performance throughput at speeds up to 10 Gbps Full duplex mode Maximum transmission units MTUs up to 9192 bytes 64 source MAC address filters 960 destination MAC fil 45 individual wavelengths 1528 77 nm 1529 55 nm 1530 33 nm 1531 12 nm 1531 90 nm 1532 68 nm 1533 1537 40 nm 1542 94 nm 1543 1547 72 nm 1548 52 n nm 1553 33 nm 1554 1558 17 nm 1558 98 n nm 1563 86 nm ers 47 nm 1534 25 nm 1535 04 nm 1535 82 nm 1536 61 nm nm 1538 19 nm 1538 98 nm 1539 77 nm 1540 56 nm 1541 35 nm 1542 14 73 nm 1544 53 nm 1545 32 nm 1546 12 nm 1546 92 nm m 1549 32 nm 1550 12 nm 1550 92 nm 1551 72 nm 1552 52 13 nm 1554 94 nm 1555 75 nm 1556 56 nm 1557 36 nm m 1559 79 nm 1560 61 nm 1561 42 nm 1562 23 nm 1563 05 78 Em 10 Gigabit Ethernet DWDM PIC Software features 10 Gigabit Ethernet DWDM PIC Enhanced optical monitoring capabilities CLI configurable wavelength support Virtual Router Redundancy Protocol VRRP support 802 1q virtual L
82. nframed mode and G 704 framed mode with CRC this feature is user configurable NOTE The G 704 implementation supports speeds slower than 2 048 Mbps multiple channels within a single E1 interface are not supported Configurable clock source Internal or loop Encapsulations E High Level Data Link Control HDLC m Frame Relay m Circuit cross connect CCC Point to Point Protocol PPP Cables and connectors Two versions m Four RJ 48 connectors one per port a Four coaxial connectors Custom 10 ft 3 05 m posilock to BNC male cable separate Rx and Tx LEDs One tricolor per port Off Not enabled Green Online with no alarms or failures Amber Online with alarms for remote failures Red Active with a local alarm router has detected a failure Alarms errors and events Alarm indication signal AIS Bipolar violations Excessive zeros Far end block errors FEBE E bit errors Loss of frame LOF Loss of signal LOS Local and remote loopback diagnostics Yellow alarm bit X bit disagreements E1 PICs m 51 M120 Internet Router PIC Guide E3 IQ PIC o Gas ss 3 E ss ge g003160 Software release JUNOS 8 0R2 and later Type 1 NOTE This PIC is not supported in JUNOS Release 8 1R1 Description Four E3 ports Power requirement 0 38 A 48 V 18 W Intelligent queuing IQ PICs support fine grained queuing per logical interface H
83. nt queuing IQ PICs support fine grained queuing per logical interface m Optical interface support See Table 16 on page 64 Hardware features High performance throughput on each port at speeds up to 1 Gbps m Full duplex mode Large MTUs of up to 9192 bytes Software features m Optical diagnostics and related alarms Quality of service QoS per channel weighted round robin WRR random early detection RED weighted random early detection WRED m Virtual Router Redundancy Protocol VRRP support E 802 1q virtual LANs VLANs m VLAN stacking and rewriting m Flexible Ethernet encapsulation m MAC policing accounts and filters m JUNOS Release 7 0 or later is required to configure graceful Routing Engine switchover GRES Gigabit Ethernet IQ PICs with SFP gm 63 M120 Internet Router PIC Guide Cables and connectors m You can install any transceiver supported by the PIC For information about installing and removing transceivers see the PIC and Transceiver Installation Instructions m Fiber optic SFP transceivers m Duplex LC PC connector Rx and Tx Optical interface support see Table 16 on page 64 E 1000Base T SFP transceivers m Connector Four pair Category 5 shielded twisted pair connectivity through an RJ 45 connector Pinout MDI crossover Length 328 ft 100 m NOTE Do not install SONET SDH OC48c STM16 SFPs in the Gigabit Ethernet port The port will not recognize the SFP LEDs Status LED one trico
84. ooling of the system M120 routers support the Type 1 Type 2 and Type 3 FPCs listed in Table 2 on page 6 and the Compact FPCs cFPCs listed in Table 3 on page 6 Table 6 on page 9 provides a PIC FPC compatibility matrix for the supported PICs for the M120 router For a complete list of end of life FPCs and end of life Enhanced FPCs for M series and T series routing platforms see the M series and T series Routing Platform End of Life FPC Guide located at http www juniper net techpubs Table 1 PICs Supported by the M120 Internet Router First JUNOS PIC Family and Type Ports Support Page ATM2 IQ ATM2 DS3 IQ 4 8 0R2 20 ATM2 E3 IQ 4 8 0R2 22 ATM2 OC3 STM1 IQ 2 8 0R2 24 ATM2 OC12 STM4 IQ 1 8 0R2 27 ATM2 OC12 STM4 IQ 2 8 0R2 27 ATM2 OC48 STM16 IQ with SFP 1 8 0R2 30 Channelized IQ Channelized DS3 IQ 4 8 0R2 33 Channelized E1 IQ 10 8 0R2 35 Channelized OC3 IQ 1 8 0R2 37 Channelized OC12 IQ 1 8 0R2 40 Channelized STM1 IQ 1 8 0R2 43 Channelized T1 IQ 10 8 0R2 45 DS3 E1 E3 and T1 DS3 4 8 0R2 48 El 4 8 0R2 50 T1 4 8 0R2 112 E3 IQ E3 IQ 4 8 0R2 52 EIA 530 EIA 530 2 8 0R2 54 Fast Ethernet Fast Ethernet 4 8 0R2 56 Fast Ethernet 8 8 0R2 56 Fast Ethernet 12 8 0R2 56 Fast Ethernet 48 8 0R2 56 Gigabit Ethernet 10 Gigabit Ethernet with XENPAK 1 8 0R2 73 M120 Internet Router PIC Guide Table 1 PICs Supported by the M120 Internet Router continued First JUNOS PIC Family and Type Ports Support
85. ped HP UNEQ L H Multiplex section remote defect indication MS RDI Higher path remote defect indication HP RDI m Errored seconds ES S ES L ES P far end errored seconds ES LFE ES PFE far end severely errored seconds SES LFE SES PFE far end unavailable seconds UAS LFE UAS m Seve PFE ely errored framing SEF severely errored framing seconds SEFS S severely errored seconds SES S SES L SES P unavailable seconds UAS L UAS P 92 uE SONET SDH 0C12c STMA4 PIC SONET SDH 0C12c STMA4 PIC Table 28 Optical Interface Support for SONET SDH 0C12c STM4 PICs Parameter Intermediate Reach Multimode Optical interface Single mode Multimode Transceiver type Fixed Fixed Standard Maximum distance Transmitter wavelength Average launch power Receiver saturation Receiver sensitivity Telcordia GR 253 SMF cable 9 3 miles 15 km 1274 through 1356 nm 15 through 8 dBm 8 dBm 28 dBm Multivendor agreement MMF cable 546 8 yards 500 m 1270 through 1380 nm 20 through 14 dBm 14 dBm 26 dBm SONET SDH 0C12c STM4 PIC mf 93 M120 Internet Router PIC Guide SONET SDH 0C12 STM4 Multi Rate PICs with SFP Ds UTE Rare MULT Rare o NET Sfp oO SONET Sfp Ostatus m Elies 4 Le ican ae D o laa f 35 Iia a wen S NAIK E Ja 8 oe lem K Ry Sag Qe wn Left 1 port
86. pped HP UNEQ Multiplex section remote defect indication MS RDI Higher path remote defect indication HP RDI m Errored seconds ES S ES L ES P far end errored seconds ES LFE ES PFE far end severely errored seconds SES LFE SES PFE far end unavailable seconds UAS LFE UAS E Seve PFE ely errored framing SEF severely errored framing seconds SEFS S severely errored seconds SES S SES L SES P unavailable seconds UAS L UAS P Table 32 Optical Interface Support for SONET SDH OC48c STM16 PICs with SFP Parameter Short Reach SR Intermediate Reach IR Long Reach LR Optical interface Single mode Single mode Single mode compatible with 1550 nm single mode LR Transceiver type SFP SFP SFP SONET SDH OC48c STM16 PIC with SFP mf 101 M120 Internet Router PIC Guide Table 32 Optical Interface Support for SONET SDH OC48c STM16 PICs with SFP continued Parameter Short Reach SR Intermediate Reach IR Long Reach LR Maximum distance SMF cable 1 24 miles 2 km SMF cable 9 3 miles 15 km SMF cable 49 71 miles 80 km Standard Telcordia GR 253 Telcordia GR 253 Telcordia GR 253 L 16 3 Transmitter 1266 through 1360 nm 1260 through 1360 nm 1500 through 1580 nm wavelength Average launch power 10 through 3 dBm 5 through 0 dBm 2 through 3 dBm Receiver saturation 3 dBm 0 dBm 9 dBm Receiver sensitivity 18 dBm 18 dBm 28 dBm 102 mm _ SONET SDH 0C48c STM16 PIC with SFP SONET SDH
87. ress 802 1q virtual LANs VLANS Point to Point Protocol over Ethernet PPPoE over VLAN JUNOS Release 8 5 and later VLAN stacking and rewriting Channels defined by two stacked VLAN tags Multiple tag protocol identifiers TPID support IP service for nonstandard TPID and stacked VLAN tags 802 1p rewrite per channel Flexible mapping of channels and scheduler resources at both ingress and egress Flexible Ethernet encapsulation MAC learning policing accounting and filtering Cables and connectors m You can install any transceiver supported by the PIC For information about installing and removing transceivers see the PIC and Transceiver Installation Instructions m Fiber optic 10 gigabit small form factor pluggable XFP transceivers m Duplex LC PC connector Rx and Tx m Optical interface support See Table 18 on page 72 LEDs OK LED one tricolor m Off PIC is offline and safe to remove from the router m Green PIC is operating normally m Amber PIC is initializing m Red PIC has an error or failure APP LED one m Off Monitoring application is not running m Green Monitoring application is running under acceptable load m Amber Monitoring application is overloaded Link Status LED one m Off Port is down m Green Port is online Link is established 10 Gigabit Ethernet IQ2 PIC with XFP m7 M120 Internet Router PIC Guide Table 18 Optical Interface for 10 Gigabit Ethernet
88. rt for SONET SDH OC3 STM1 Multi Rate PICs Configured at an OC3 STM1 Rate continued Parameter Multimode Intermediate Reach IR 1 Long Reach LR 1 Optical interface Multimode Single mode Single mode Transceiver type SFP SFP SFP Maximum distance Standard Transmitter wavelength Average launch power Receiver saturation Receiver sensitivity MMF cable 1 2 miles 2 km Multivendor agreement 1270 through 1380 nm 20 through 14 dBm 14 dBm 30 dBm SMF cable 9 3 miles 15 km Telcordia GR 253 1261 through 1360 nm 15 through 8 dBm 8 dBm 28 dBm SMF cable 24 85 miles 40 km Telcordia GR 253 1263 through 1360 nm 5 through 0 dBm 10 dBm 34 dBm Table 27 Optical Interface Support for SONET SDH OC3 STM1 Multi Rate PICs Configured at an 0C12 STM4 Rate Parameter Short Reach SR 1 Intermediate Reach IR 1 Long Reach LR 1 Transceiver model number Optical interface Transceiver type Maximum distance Standard Transmitter wavelength Average launch power Receiver saturation Receiver sensitivity SFP OC12 SR Single mode SFP SMF cable 1 24 miles 2 km Telcordia GR 253 1261 through 1360 nm 15 through 8 dBm 8 dBm 23 dBm SFP OC12 IR Single mode SFP SMF cable 9 3 miles 15 km Telcordia GR 253 1274 through 1356 nm 15 through 8 dBm 8 dBm 28 dBm SFP OC12 LR Single mode SFP SMF cable 24 85 miles 40 km Telcordia GR 253 1280 through 133
89. signal MS AIS Administrative unit alarm indication signal AU AIS Bit error rate signal degrade BERR SD Bit error rate signal fail BERR SF Bit interleaved parity BIP error B1 Bit interleaved parity BIP error B2 Bit interleaved parity BIP error B3 Loss of frame LOF Loss of pointer HP LOP Loss of signal LOS Multiplex section remote error indication MS RE I Higher path label mismatch HP PLM Higher path unequipped HP UNEQ Multiplex section remote defect indication MS RDI Higher path remote defect indication HP RDI Errored seconds ES S ES L ES P far end errored seconds ES LFE ES PFE far end severely errored seconds SES LFE SES PFE far end unavailable seconds UAS LFE UAS Seve PFE ely errored framing SEF severely errored framing seconds SEFS S severely errored seconds SES S SES L SES P unavailable seconds UAS L UAS P Table 29 Optical Interface Support for SONET SDH 0C12 STM4 Multi Rate PICs Configured at an OC3 STM1 Rate Parameter Multimode Intermediate Reach IR 1 Long Reach LR 1 Transceiver model SFP OC3 SR SFP OC3 IR SFP OC3 LR number 96 mm SONET SDH 0C12 STM4 Multi Rate PICs with SFP SONET SDH 0C12 STM4 Multi Rate PICs with SFP Table 29 Optical Interface Support for SONET SDH 0C12 STM4 Multi Rate PICs Configured at an OC3 STM1 Rate continued Parameter Multimode Intermediate Reach IR 1 Long Reach LR 1 Optical interfa
90. support fine grained queuing per logical interface Conforms to ANSI T1 105 1991 and T1E1 2 93 020R1 Complies with ATM and SONET SDH standards Alarm and event counting and detection Compatible with well known ATM switches ATM switch ID which displays the switch IP address and local interface name of the adjacent Fore ATM switches Optical interface support see Table 11 on page 31 Hardware features ATM2 IQ 1 port OC48 PICs have one 3010 SAR for segmentation and reassembly into 53 byte ATM cells High performance parsing of SONET SDH frames ASIC based packet segmentation and reassembly SAR management and output port queuing 64 MB SDRAM memory for ATM SAR Packet buffering Layer 2 parsing 30 m ATM2 0C48 STM16 IQ PIC with SFP ATM2 0C48 STM16 IQ PIC with SFP Software features m Multiprotocol Label Switching MPLS circuit cross connect for leveraging ATM access networks User configurable virtual circuit VC and virtual path VP support Support for idle cell or unassigned cell transmission OAM fault management processes alarm indication signal AIS remote defect indicator RDI and loop cells m Point to point and point to multipoint mode Layer 2 counters per VC and per VP Local and remote loopback ATM Inverse ARP which enables routers to automatically learn the IP address of the router on the far end of an ATM PVC m Simple Network Management Protocol SNMP E Management Information Base MIB 2 RFC 121
91. the laser when a PIC is not being actively used with any valid links take the PIC offline until you are ready to establish a link to another device For information about taking a PIC offline see the request chassis pic offline command in the JUNOS System Basics and Services Command Reference LEDs One tricolor per port m Off Not enabled E Green Online with no alarms or failures m Amber Online with alarms for remote failures m Red Active with a local alarm router has detected a failure 104 SONET SDH 0C48 STM16 Multi Rate PIC with SFP Alarms errors and events SON SDH SONET SDH 0C48 STM16 Multi Rate PIC with SFP ET alarms Alarm indication signal line AIS L Alarm indication signal path AIS P Bit error rate signal degrade BERR SD Bit error rate signal fail BERR SF Bit interleaved parity BIP error B1 Bit interleaved parity BIP error B2 Bit interleaved parity BIP error B3 Loss of frame LOF Loss of pointer LOP P Loss of signal LOS Far end bit error remote error indication line REI L CV LFE Far end bit error remote error indication path REI P CV PFE Payload mismatch path label mismatch PLM P Payload unequipped unequipped STS at path level UNEQ P Remote defect indication line RDI L Remote defect indication path RDI P alarms Multiplex section alarm indication signal MS AIS Administrative unit alarm indication signal AU AIS Bit error rat
92. ty 28 dBm 20 through 14 dBm 14 dBm 30 dBm 86 mm SONET SDH OC3c STM1 PIC SONET SDH 0C3 STM1 Multi Rate PICs with SFP SONET SDH OC3 STM1 Multi Rate PICs with SFP MULTI Ry SONET SFR E n El Ae ou 1 140d O ony INE sttus OFFLINE Left SONET SDH OC3 STM1 Multi Rate PIC Type 1 Right SONET SDH OC3 STM1 Multi Rate PIC Type 2 Software release 4 port JUNOS 8 4 and later Type 1 4 port JUNOS 8 3 and later Type 2 Description Rate selectable using one of the following rates m port OC12 m port OC12c m 4port OC3c Power requirement 0 40 A 48 V 19 W Hardware features Multiplexing and demultiplexing Rate policing on input Rate shaping on output Packet buffering Layer 2 parsing SONET SDH OC3 STM1 Multi Rate PICs with SFP 87 M120 Internet Router PIC Guide Software features Optical diagnostics and related alarms Per port SONET SDH framing Link aggregation Alarm and event counting and detection Dual router automatic protection switching APS Multiprotocol Label Switching MPLS fast reroute Encapsulations E High Level Data Link Control HDLC Frame Relay Circuit cross connect CCC Translational cross connect TCC Point to Point Protocol PPP Cables and connectors You can install any transceiver support
93. u ONLINE OFFLINE Software release m 10 Gigabit Ethernet PIC with XENPAK JUNOS 8 0R2 and later Type 3 m XENPAK OTN transceivers JUNOS 9 0R2 and later NOTE This PIC is not supported in JUNOS Release 8 1R1 Description m One 10 Gigabit Ethernet port Power requirement 0 55 A 48 V 26 6 W Supports large Ethernet frame sizes for more efficient throughput across the intra POP network m Optical interface support See Table 19 on page 74 and Table 20 on page 75 Hardware features High performance throughput at speeds up to 10 Gbps Full duplex mode Maximum transmission units MTUs up to 9192 bytes 64 source MAC address filters 960 destination MAC filters Software features Virtual Router Redundancy Protocol VRRP support 802 1q virtual LANs VLANs support 802 3ae link aggregation support RMON EtherStats Optical diagnostics and related alarms m Transceiver temperature m Laser bias current m Laser output power a Receive optical power 10 Gigabit Ethernet PIC with XENPAK m 73 M120 Internet Router PIC Guide Cables and connectors m Duplex SC PC connector RX and TX m Optical interface support See Table 19 on page 74 and Table 20 on page 75 LEDs Status LED one bicolor m Off PIC not enabled m Green PIC is operating normally m Red PIC has an error or failure Port LEDs one pair m Link If green the port is online if there is no light th
94. ures Red Active with a local alarm router has detected a failure 100 gm _ SONET SDH 0C48c STM16 PIC with SFP Alarms errors and m SON events a E E E E E E E E E E E E E E E SDH E E E E E E E E E E E E E E E SONET SDH OC48c STM16 PIC with SFP ET alarms Alarm indication signal line AIS L Alarm indication signal path AIS P Bit error rate signal degrade BERR SD Bit error rate signal fail BERR SF Bit interleaved parity BIP error B1 Bit interleaved parity BIP error B2 Bit interleaved parity BIP error B3 Loss of frame LOF Loss of pointer LOP P Loss of signal LOS Far end bit error remote error indication line REI L CV LFE Far end bit error remote error indication path REI P CV PFE Payload mismatch path label mismatch PLM P Payload unequipped unequipped STS at path level UNEQ P Remote defect indication line RDI L Remote defect indication path RDI P alarms Multiplex section alarm indication signal MS AIS Administrative unit alarm indication signal AU AIS Bit error rate signal degrade BERR SD Bit error rate signal fail BERR SF Bit interleaved parity BIP error B1 Bit interleaved parity BIP error B2 Bit interleaved parity BIP error B3 Loss of frame LOF Loss of pointer HP LOP Loss of signal LOS Multiplex section remote error indication MS RE I Higher path label mismatch HP PLM Higher path unequi
95. vent counting and detection m Dual router automatic protection switching APS m Multiprotocol Label Switching MPLS fast reroute m Encapsulations E High Level Data Link Control HDLC Frame Relay Circuit cross connect CCC Translational cross connect TCC Point to Point Protocol PPP 108 m SONET SDH OC192c STM64 PIC with XFP Cables and connectors SONET SDH 0C192c STM64 PIC with XFP m Duplex LC connector Rx and Tx m Optical interface support See Table 36 on page 110 NOTE To extend the life of the laser when a PIC is not being actively used with any valid links take the PIC offline until you are ready to establish a link to another device For information about taking a PIC offline see the request chassis pic offline command in the JUNOS System Basics and Services Command Reference LEDs One tricolor LED per port Off Not enabled Green Online with no alarms or failures Amber Online with alarms for remote failures Red Active with a local alarm router has detected a failure SONET SDH 0C192c STM64 PIC with XP mf 109 M120 Internet Router PIC Guide Alarms errors and m SONET alarms events E SDH al M Bi Bi M H H M H Alarm indication signal line AIS L Alarm indication signal path AIS P Bit error rate signal degrade BERR SD Bit error rate signal fail BERR SF Bit interleaved parity BIP error B1 Bit interleaved parity BIP error B2 Bit interle